Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.213
Filtrar
Más filtros

Intervalo de año de publicación
1.
Proc Natl Acad Sci U S A ; 120(27): e2304498120, 2023 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-37364121

RESUMEN

The attainment of both high strength and toughness is the ultimate goal for most structural materials. Although ceramic material has been considered for use as a structural material due to its high strength and good chemical stability, it suffers from the limitation of low toughness. For instance, although Y2O3-stabilized tetragonal ZrO2 polycrystals (Y-TZPs) exhibit remarkable toughness among ceramics due to their phase transformation toughening mechanism, this toughness is still much weaker than that of metals. Here, we report Y-TZP-based ceramic materials with toughnesses exceeding 20 MPa m1/2, which is comparable to those of metals, while maintaining strengths over 1,200 MPa. The superior mechanical properties are realized by reducing the phase stability of tetragonal zirconia by tailoring the microstructure and chemistry of the Y-TZP. The proposed ceramic materials can further advance the design and application of ceramic-based structural materials.

2.
J Synchrotron Radiat ; 31(Pt 2): 355-362, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38363222

RESUMEN

In this work, Ce-doped yttria-stabilized zirconia (YSZ) and pure YSZ phases were subjected to irradiation with 14 MeV Au ions. Irradiation studies were performed to simulate long-term structural and microstructural damage due to self-irradiation in YSZ phases hosting alpha-active radioactive species. It was found that both the Ce-doped YSZ and the YSZ phases had a reasonable tolerance to irradiation at high ion fluences and the bulk crystallinity was well preserved. Nevertheless, local microstrain increased in all compounds under study after irradiation, with the Ce-doped phases being less affected than pure YSZ. Doping with cerium ions increased the microstructural stability of YSZ phases through a possible reduction in the mobility of oxygen atoms, which limits the formation of structural defects. Doping of YSZ with tetravalent actinide elements is expected to have a similar effect. Thus, YSZ phases are promising for the safe long-term storage of radioactive elements. Using synchrotron radiation diffraction, measurements of the thin irradiated layers of the Ce-YSZ and YSZ samples were performed in grazing incidence (GI) mode. A corresponding module for measurements in GI mode was developed at the Rossendorf Beamline and relevant technical details for sample alignment and data collection are also presented.

3.
Chemphyschem ; 25(14): e202300865, 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-38391116

RESUMEN

For oxygen reduction reaction (ORR), the surface adsorption energies of O and OH* intermediates are key descriptors for catalytic activity. In this work, we investigate anion-substituted zirconia catalyst surfaces and determine that adsorption energies of O and OH* intermediates is governed by both structural and electronic effects. When the adsorption energies are not influenced by the structural effects of the catalyst surface, they exhibit a linear correlation with integrated crystal orbital Hamiltonian population (ICOHP) of the adsorbate-surface bond. The influence of structural effects, due to the re-optimisation slab geometry after adsorption of intermediate species, leads to stronger adsorption of intermediates. Our calculations show that there is a change in the bond order to accommodate the incoming adsorbate species which leads to stronger adsorption when both structural and electronic effects influence the adsorption phenomena. The insights into the catalyst-adsorbate interactions can guide the design of future ORR catalysts.

4.
Clin Oral Implants Res ; 35(6): 630-640, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38567929

RESUMEN

OBJECTIVES: This RCT aimed to compare zirconia and titanium dental implants in the maxillary premolar region. The comparison was based on marginal bone level (MBL) changes, clinical parameters, aesthetic outcomes, and patient related outcome measures (PROMs) 1 year after prosthetic loading. MATERIALS AND METHODS: Fifty patients were randomly assigned to receive either a zirconia (ZrO2, n = 25) implant or a titanium (Ti, n = 25) bone-level implant. Implants were provided with a lithium disilicate crown 3 months after placement. Follow-up was at 1 month and after 1 year. The primary outcome pertained to changes in MBL. Reported secondary outcomes consisted of implant survival, peri-implant tissue health, aesthetics, and PROMs. RESULTS: Mean MBL change after 1 year was 0.01 mm (SD = 0.45; min = 0.72, max = 0.86) for ZrO2 and -0.09 mm (SD = 0.34; min = 0.53, max = -1.06) for Ti (p = .439). Scores for the other clinical outcome parameters and PROMs were generally favorable, with no significant differences. However, significant differences were found for the aesthetic outcomes regarding two criteria: (a) level of facial mucosa (p = .022), in favor of Ti, and (b) root convexity/soft tissue color and texture (p = .005) in favor of ZrO2. CONCLUSION AND CLINICAL IMPLICATIONS: The ZrO2 and Ti implant types used in this study, replacing a single missing maxillary premolar, show a comparable outcome in terms of MBL change after 1 year. Clinical and aesthetic parameters, as well as PROMs, are favorable and similar between both implant types after 1 year of prosthetic loading. These short-term study results suggest that both are suitable for clinical use.


Asunto(s)
Implantes Dentales de Diente Único , Maxilar , Titanio , Circonio , Humanos , Femenino , Masculino , Persona de Mediana Edad , Maxilar/cirugía , Adulto , Estética Dental , Anciano , Resultado del Tratamiento , Coronas , Implantación Dental Endoósea/métodos , Prótesis Dental de Soporte Implantado , Diente Premolar
5.
Artículo en Inglés | MEDLINE | ID: mdl-38953431

RESUMEN

OBJECTIVES: To evaluate the effect of different cement types on the incidence of failure and loss of retention of zirconia and metal-ceramic single crowns (SCs) cemented on implant abutments. METHODS: We placed 567 implant-supported SCs in 358 patients and retrospectively evaluated long-term retention for up to 12.8 years. The frameworks were made from metal alloy (n = 307) or zirconia (n = 260). SCs were cemented with permanent (glass-ionomer cement; n = 376) or semipermanent cement (zinc oxide non-eugenol cement; n = 191) on standardized (n = 446) or customized (n = 121) abutments. Kaplan-Meier curves were used to calculate the incidence of decementation. Differences between survival curves were assessed with log-rank tests. Cox-regression analysis was performed to evaluate multiple risk factors. RESULTS: Of the 567 SCs, 22 failed because of technical complications and four because of implant loss. Loss of retention was observed in 50 SCs. Analysis revealed a 7% probability of loss of retention for zirconia and 16% for metal-ceramic SCs after 10 years (p = .011). After 5 years, loss of retention was higher for standardized abutments than for customized abutments (p = .014). The probability of loss of retention was higher with semipermanent than with permanent cement (p = .001). Cox-regression analysis revealed semipermanent cement as the only significant risk factor for SC failure (p = .026). CONCLUSIONS: In contrast to semipermanent cement, permanent cement provides acceptable long-term retention of cemented implant-supported SCs. These possible positive effects of customized abutments have to be controlled with larger sample sizes.

6.
Artículo en Inglés | MEDLINE | ID: mdl-38804531

RESUMEN

OBJECTIVES: The glow discharge plasma (GDP) procedure has proven efficacy in grafting allylamine onto zirconia dental implant surfaces to enhance osseointegration. This study explored the enhancement of zirconia dental implant properties using GDP at different energy settings (25, 50, 75, 100, and 200 W) both in vitro and in vivo. MATERIALS AND METHODS: In vitro analyses included scanning electron microscopy, wettability assessment, energy-dispersive X-ray spectroscopy, and more. In vivo experiments involved implanting zirconia dental implants into rabbit femurs and later evaluation through impact stability test, micro-CT, and histomorphometric measurements. RESULTS: The results demonstrated that 25 and 50 W GDP allylamine grafting positively impacted MG-63 cell proliferation and increased alkaline phosphatase activity. Gene expression analysis revealed upregulation of OCN, OPG, and COL-I. Both 25 and 50 W GDP allylamine grafting significantly improved zirconia's surface properties (p < .05, p < .01, p < .001). However, only 25 W allylamine grafting with optimal energy settings promoted in vivo osseointegration and new bone formation while preventing bone level loss around the dental implant (p < .05, p < .01, p < .001). CONCLUSIONS: This study presents a promising method for enhancing Zr dental implant surface's bioactivity.

7.
Artículo en Inglés | MEDLINE | ID: mdl-38415804

RESUMEN

PURPOSE: Investigate survival and technical complications of two-unit posterior implant-supported cantilever made of monolithic zirconia on titanium-base abutments (Zr-TiB) vs. porcelain-fused-to-metal on castable gold abutments (PFM-GA) using two different implant connections, internal butt-joint (IBJ) and internal conical (IC). MATERIALS AND METHODS: Forty-eight implants (4.3 mm diameter) were divided into four groups (n = 12) to support 2-unit mandibular premolar cantilevers with two different materials (Zr-TiB vs. PFM-GA) and two connection types (IBJ vs. IC). Tested groups were as follows: (1) IBJ/Zr-TiB; (2) IBJ/PFM-GA; (3) IC/Zr-TiB; and (4) IC/PFM-GA. Specimens were thermomechanical aged (1,200,000 cycles, 98 N, 5-55°C) with occlusal axial load on the pontic. Catastrophic and non-catastrophic events were registered, and removal torque values measured before and after aging. Specimens surviving aging were subjected to loading until failure. Survival, total complication rates, torque loss (%), and bending moments were calculated. RESULTS: From 48 specimens, 38 survived aging. Survival rates significantly varied from 16.7% (IC/PFM-GA) to 100% (IBJ/Zr-TiB; IBJ/PFM-GA; IC/Zr-TiB) (p < .01). Internal conical connection revealed significantly higher torque loss (IC/ZrTiB - 67%) compared to internal butt-joint (IBJ/Zr-TiB - 44%; IBJ/PFM-GA - 46%) (p < .01). Bending moments were higher in internal butt-joint connections than in internal conical (p < .05). CONCLUSION AND CLINICAL IMPLICATIONS: Two-unit posterior implant-supported cantilever FDPs replacing mandibular premolars composed of monolithic zirconia on titanium-base abutments demonstrated higher mechanical stability compared to porcelain-fused-to-metal on castable gold abutments in this in vitro study. The internal conical connection combined with porcelain-fused-to-metal on gold abutments revealed a high number of failures; therefore, their clinical use may be considered cautiously for this indication.

8.
Artículo en Inglés | MEDLINE | ID: mdl-39056305

RESUMEN

OBJECTIVE: To assess the clinical, radiographic and patient-reported outcomes (PROMs) of posterior zirconia and titanium implants at 1 year of implant loading. MATERIALS AND METHODS: Forty-two patients with two adjacent missing teeth were enrolled in a randomized controlled trial with a within-subject controlled design. Each patient received one zirconia (Zr) and one titanium (Ti) implant, with the mesial and distal positions randomized. The implant restoration consisted of multiple layered zirconia, with the buccal aspect veneered. In group Zr, the restoration was intraorally cemented onto the one-piece Zr implant, whereas in group Ti, the restoration was extraorally cemented onto the titanium base abutment and intraorally screw-retained onto the Ti implant. Examinations were performed following restoration delivery at baseline (BL) and at 1 year. Measurements included clinical parameters, radiographic outcomes (MBL) and PROMs. RESULTS: Bleeding on probing showed an increase from BL to 1 year (34 ± 30% for Zr; 25 ± 21% for Ti). MBL remained stable with minimal changes from BL to 1 year, measuring 0.1 ± 0.4 mm (mean ± SD) for Zr and -0.1 ± 0.7 mm for Ti. Veneering fractures were the most frequent technical complication and amounted to 17.5% in group Zr and 5% in group Ti (p = .100). Patients preferred Zr implants for their soft tissue color, with a significant difference in perception between patients and clinicians (p < .017). CONCLUSION: The study showed that both Zr and Ti implants had similar clinical outcomes, despite a high prevalence of mucositis and a few technical complications. Both implant types demonstrated stable marginal bone levels and similar patient-reported outcome measures.

9.
Clin Oral Implants Res ; 35(7): 685-693, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38594815

RESUMEN

OBJECTIVES: Clinical data on all-ceramic screw-retained implant crowns (SICs) luted on titanium base abutments (TBAs) over more than 3 years are sparse. This study aimed to evaluate the clinical performance and potential risk factors for these restorations. MATERIALS AND METHODS: Analysis took place based on the medical patient-records of three dental offices. Implant survival and prosthetic complications over time were evaluated. The study included SICs in premolar and molar regions made from monolithic lithium disilicate ceramic (M_LiDi) or veneered zirconia (V_ZiO) luted on a TBA documented over an observation time of at least 3 years. Survival and complication rates were calculated and compared by a log-rank test. Cox-Regressions were used to check potential predictors for the survival (p < .05). RESULTS: Six hundred and one crowns out of 371 patients met the inclusion criteria and follow-up period was between 3.0 and 12.9 (mean: 6.4 (SD: 2.1)) years. Over time, six implants had to be removed and 16 restorations had to be refabricated. The estimated survival rates over 10 years were 93.5% for M_LiDi and 95.9% for V_ZiO and did not differ significantly among each other (p = .80). However, V_ZiO showed significantly higher complication rates (p = .003). Material selection, sex, age, and implant diameter did not affect the survival of investigated SICs but crown height influences significantly the survival rate (hazard ratio, HR = 1.26 (95%CI: 1.08, 1.49); p = .043). CONCLUSIONS: Screw-retained SICs luted on TBAs that were fabricated from monolithic lithium disilicate ceramic or veneered zirconia showed reliable and similar survival rates. Increasing crown heights reduced survival over the years.


Asunto(s)
Cerámica , Coronas , Fracaso de la Restauración Dental , Humanos , Estudios Retrospectivos , Factores de Riesgo , Masculino , Femenino , Persona de Mediana Edad , Adulto , Prótesis Dental de Soporte Implantado , Anciano , Circonio , Porcelana Dental , Diseño de Prótesis Dental
10.
Artículo en Inglés | MEDLINE | ID: mdl-38940623

RESUMEN

OBJECTIVES: The aim of this study was to evaluate esthetic parameters in the anterior maxillary region by comparing single-piece zirconia versus titanium narrow-diameter implants. Additionally, clinical, radiological and patient-reported outcome measures (PROMs) were analyzed. MATERIALS AND METHODS: Thirty implants (tissue level implant) were placed in 30 patients in the maxillary esthetic sector. Depending on randomization, a zirconia (test) or titanium implant (control) was placed. Esthetic, clinical, and radiological parameters, including the implant crown esthetic index (ICAI), pink esthetic score (PES), probing pocket depth, bleeding on probing, plaque index, and marginal bone levels, were evaluated at 12, 36 and 60 months after loading. RESULTS: Sixty months after crown placement, no significant differences were found between groups. The ICAI values were 5.25 ± 4.21 and 4.50 ± 2.98 for the test and control groups, respectively. The corresponding PES values were 7.44 ± 1.93 and 7.43 ± 1.74 for the test and control groups, respectively. There were no significant intergroup differences for the rest of the parameters evaluated. CONCLUSION: It can be suggested that monotype zirconia implants may serve as a potential alternative to titanium implants in selected clinical scenarios. While the results demonstrated comparable esthetic, clinical, and radiological aspects for zirconia implants as compared to titanium implants after a 5-year follow-up period, further research with larger sample sizes and longer-term follow-up is recommended.

11.
Eur J Oral Sci ; 132(1): e12959, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37864371

RESUMEN

The present study aimed to compare the microstructure, physical, and mechanical properties of three commercially available dental polychromatic multilayer zirconia materials of uniform composition: Dima Mill Zirconia ML, VITA YZ/ST Multicolor, and VITA YZ/XT Multicolor (with 3, 4, and 5 mol% Y2 O3 , respectively); thus, the influence of Y2 O3 content on the above properties of the produced materials was experimentally studied. Homogeneous zirconia ceramics with a dense micro- and nanostructure, without pores or defects, were produced after milling the blocks and sintering, which resulted in yttrium-stabilized tetragonal and cubic zirconia. Statistical analysis of the results of measurable magnitudes was performed by the one-way ANOVA test. The increase of Y2 O3 content (from 3 to 5 mol%) favored larger grain and crystallite sizes and a decrease of the values of the mechanical properties; yet, the differences were statistically insignificant. Clinically, these differences are expected to have no impact on their function in the oral cavity, both in terms of their fracture propensity and the damage that can be caused to the opposing teeth. Accordingly, the experimental results qualify the polychromic multilayer zirconia ceramics of uniform composition fabricated by milling technology for use in dental restorations.


Asunto(s)
Cerámica , Materiales Dentales , Materiales Dentales/química , Ensayo de Materiales , Cerámica/química , Circonio/química , Propiedades de Superficie
12.
Eur J Oral Sci ; 132(3): e12989, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38679835

RESUMEN

This study aimed at examining the bond strength between zirconia and ceramic veneer, following the ISO 9693 guidelines. A total of fifty specimens of zirconia/ceramic-veneer system were produced using two commercial zirconias (VITA YZ-HTWhite and Zolid HT+ White, referred to as Group A and Group B, respectively) and a ceramic-veneering material (Zirkonia 750). The microstructure (via x-ray diffraction analysis, XRD and Secondary Electron mode, SEM) and the mechanical properties (via 3-point bending tests) of the two groups were assessed. Then, experiments were conducted according to the ISO 9693 and conventional protocols applied for producing zirconia/ceramic-veneer restorations. Bond strength values, measured by 3-point bending tests, were 34.42 ± 7.60 MPa for Group A and 31.92 ± 6.95 MPa for Group B. SEM observations of the cohesively fractured surfaces (on the porcelain side) and the examination for normality using the Shapiro-Wilk test suggested the use of Weibull statistical analysis. Median strength (σ50%) for Group A and Group B was 34.76 and 32.22 MPa, while the characteristic strength (σ63.2%) was 35.78 and 33.14 MPa, respectively. The Weibull modulus disparity between groups (12.69 and 13.07) was not significant. Bond strength exceeded the ISO 9693 minimum of 20 MPa, suggesting satisfactory strength for clinical use.


Asunto(s)
Recubrimiento Dental Adhesivo , Porcelana Dental , Análisis del Estrés Dental , Coronas con Frente Estético , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Difracción de Rayos X , Circonio , Circonio/química , Porcelana Dental/química , Propiedades de Superficie , Cerámica/química , Materiales Dentales/química , Humanos
13.
Mater Chem Phys ; 324: 129703, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39021367

RESUMEN

Background: Dental glass-ceramics have limited strength and are unsuitable for high-stress-bearing areas. Zirconia stands out as a popular choice for reinforcing dental glass-ceramics due to its biocompatibility and high fracture toughness. Objectives: The objective of the study is to investigate the effect of an increase in zirconia (25, 30, 35 and 50 wt%) on microstructure, chemical solubility, hardness, fracture toughness, and brittleness index of fluorosilicate glass systems for dental restorative applications. Material and methods: The fluorosilicate glass frit was obtained through the melt-quench technique. The glass frit was ball-milled with 25, 30, 35 and 50 wt % of 3 mol% yttria-stabilized zirconia (G-25Z, G-30Z, G-35Z, and G-50Z). The composites were sintered to 1000 °C for 48h at a heating rate of 5 °C/min. The glass frit was subject to differential scanning calorimetry. Phase analysis and microstructural characterization were carried out. The crystallite size of zirconia and glass-ceramics, micro-hardness, indentation fracture toughness, brittleness index, and chemical solubility were evaluated. Results: Phase analysis reveals tetragonal and monoclinic zirconia with minor peaks of forsterite, fluorphlogopite, norbergite, and spinel. Their microstructures reveal the characteristic house-of-cards arrangement of fluorophlogopite crystals with dispersed zirconia. The results of hardness and fracture toughness show a statistically significant improvement with an increase in zirconia content. The crystallite size of zirconia and fluorophlogopite crystals with aspect ratio, brittleness index, and chemical solubility declined as the zirconia content increased. Conclusions: Increase in zirconia content from 25 wt % to 50 wt % in heat-treated fluorosilicate glass systems reveals non-reactive zirconia with a stable glass matrix and limits the growth of fluorphlogopite crystals with a house-of-cards microstructure. This results in a range of properties suitable for dental restorations of enhanced hardness, and improved fracture toughness. Despite these improvements, the material maintains its machinability with reduced chemical solubility.

14.
Clin Oral Investig ; 28(7): 380, 2024 Jun 18.
Artículo en Inglés | MEDLINE | ID: mdl-38886209

RESUMEN

OBJECTIVE: To describe the clinical and radiographic performance and survival rate of a new two-piece ceramic implant system after at least 12 months of follow-up. MATERIALS AND METHODS: Sixty-five implants were placed and followed up for at least 12 months (12.3 ± 1.5), in 50 patients. The implants were installed both in fresh extraction sockets and in healed sites and received provisional restoration when the clinical insertion torque was greater than 35Ncm. The primary results describe the survival rate of these implants. Clinical performance was evaluated through the evaluation of the Pink Esthetic Score (PES) and the degree of satisfaction of the patients. Bone loss was measured through radiographic measurements of the marginal bone loss in the mesial (MBLM) and distal (MBLD) sites. RESULTS: The survival rate was 98.5%. The average MBLM was 0.24 mm (± 0.53) and the MBLD was 0.27 mm (± 0.57). A statistical difference was observed only when comparing immediate implants with delayed ones (MBLM - p = 0.046 and MBLD - p = 0.028) and when they received immediate provisionalization or not (MBLM - p = 0.009 and MBLD - p = 0.040). The PES before the intervention (T0) was 13.4 (± 0.8) and the PES at T2 (12-month follow-up) was 12.9 (± 1.5) (p = 1.14). CONCLUSION: The new two-piece ceramic implant used in the present study showed predictable and reliable results, similar to those found with titanium implants after one year of follow-up. CLINICAL RELEVANCE: These implants can be used as an alternative to titanium implants in terms of the marginal bone loss and the degree of patient satisfaction.


Asunto(s)
Cerámica , Diseño de Prótesis Dental , Humanos , Estudios Prospectivos , Masculino , Femenino , Persona de Mediana Edad , Cerámica/química , Resultado del Tratamiento , Adulto , Satisfacción del Paciente , Anciano , Estética Dental , Pérdida de Hueso Alveolar/diagnóstico por imagen , Alveolo Dental/cirugía , Alveolo Dental/diagnóstico por imagen , Fracaso de la Restauración Dental , Implantes Dentales
15.
Clin Oral Investig ; 28(6): 305, 2024 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-38722356

RESUMEN

OBJECTIVE: To evaluate the ability of the water glass treatment to penetrate zirconia and improve the bond strength of resin cement. MATERIAL AND METHODS: Water glass was applied to zirconia specimens, which were then sintered. The specimens were divided into water-glass-treated and untreated zirconia (control) groups. The surface properties of the water-glass-treated specimens were evaluated using surface roughness and electron probe micro-analyser (EPMA) analysis. A resin cement was used to evaluate the tensile bond strength, with2 and without a silane-containing primer. After 24 h in water storage at 37 °C and thermal cycling, the bond strengths were statistically evaluated with t-test, and the fracture surfaces were observed using SEM. RESULTS: The water glass treatment slightly increased the surface roughness of the zirconia specimens, and the EPMA analysis detected the water glass penetration to be 50 µm below the zirconia surface. The application of primer improved the tensile bond strength in all groups. After 24 h, the water-glass-treated zirconia exhibited a tensile strength of 24.8 ± 5.5 MPa, which was significantly higher than that of the control zirconia (17.6 ± 3.5 MPa) (p < 0.05). After thermal cycling, the water-glass-treated zirconia showed significantly higher tensile strength than the control zirconia. The fracture surface morphology was mainly an adhesive pattern, whereas resin cement residue was occasionally detected on the water-glass-treated zirconia surfaces. CONCLUSION: The water glass treatment resulted in the formation of a stable silica phase on the zirconia surface. This process enabled silane coupling to the zirconia and improved the adhesion of the resin cement.


Asunto(s)
Recubrimiento Dental Adhesivo , Vidrio , Ensayo de Materiales , Cementos de Resina , Silanos , Propiedades de Superficie , Resistencia a la Tracción , Agua , Circonio , Circonio/química , Cementos de Resina/química , Silanos/química , Agua/química , Recubrimiento Dental Adhesivo/métodos , Vidrio/química , Microscopía Electrónica de Rastreo , Análisis del Estrés Dental
16.
Clin Oral Investig ; 28(2): 145, 2024 Feb 13.
Artículo en Inglés | MEDLINE | ID: mdl-38351386

RESUMEN

OBJECTIVES: To compare the strength and reliability of 3D-printed 3Y-TZP zirconia manufactured with various printing orientations and staining. MATERIALS AND METHODS: A total of one-hundred cylindrical zirconia specimens were designed and fabricated using 3D printing and processed according to ISO 6872 standards. Of these specimens, 80 were 3D printed using the new ZIPRO-D (ZD) 3D ceramic printer. In this ZD group, 60 specimens were printed in a vertical orientation and were either stained after debinding (ZD1, x-orientation, n = 20) or not stained (ZD2, x-orientation, n = 20; ZD3, y-orientation, n = 20) and the remaining 20 specimens out of n = 80 were printed in a horizontal orientation (ZD4). Further 20 specimens out of the entire sample N = 100 were printed vertically with the CeraFab7500 3D ceramic printer (LC). All completed specimens were loaded until fracture using a universal testing machine. Biaxial flexural strengths and Weibull parameters were computed for the ZD groups and for the LC group. Group and sub-group effects were evaluated using Welch ANOVA (alpha = 0.05). RESULTS: The mean (standard deviation, SD) biaxial flexural strengths of vertically oriented ZD samples with (ZD1) and without (ZD2/ZD3) staining were 811 (197) and 850 (152) MPa, respectively (p > 0.05). The ZD4 (horizontally printed), 1107 (144) MPa, and LC (1238 (327)) MPa samples had higher mean (SD) flexural strengths than the ZD1-3 specimens. No difference was observed between the ZD4 and LC group (p > 0.05). Weibull moduli were between m = 4.6 (ZD1) and 9.1 (ZD4) in the ZD group and m = 3.5 in the LC group. CONCLUSIONS: All tested 3D-printed zirconia specimens exceeded the flexural strengths required for class 5 restorations according to ISO 6872 standards. While the flexural strengths of zirconia printed using the novel ZD device in the vertical orientation are lower than those of zirconia printed using the LC printer, the ZD printer shows at least comparable reliability. CLINICAL RELEVANCE: 3D-printing of zirconia is a new technology in dental application. Based on the presented strengths values, clinical application of 3D-printed zirconia for fixed dental protheses can be recommended.


Asunto(s)
Cerámica , Resistencia Flexional , Ensayo de Materiales , Reproducibilidad de los Resultados , Propiedades de Superficie , Circonio , Impresión Tridimensional , Materiales Dentales
17.
Clin Oral Investig ; 28(2): 128, 2024 Jan 31.
Artículo en Inglés | MEDLINE | ID: mdl-38294555

RESUMEN

OBJECTIVES: This in vitro study aimed to evaluate the wear of natural teeth opposing 3 mol% yttria-stabilized tetragonal zirconia polycrystal (3Y-TZP) with different surface conditions. MATERIALS AND METHODS: Sixty 3Y-TZP specimens were randomly assigned to six groups (n = 10), differing in surface condition. In three groups, the samples underwent glazing-with the glaze applied to roughened (i.e., 106-µm-grit diamond-finished), as-sintered, and polished zirconia. The three remaining groups consisted of unglazed specimens: solely polished samples and diamond-finished samples (106-µm-grit and 46-µm-grit) without further conditioning. Two-body wear was evaluated at extracted, non-carious molars (n = 60), which served as antagonists in chewing simulation (10,000 masticatory cycles, 49N load). As a control, natural teeth with intact enamel surfaces were tested against natural molars (n = 10). All samples were 3D-scanned before and after the chewing simulation (7 Series, Straumann). Volume loss was calculated (Inspect Software, GOM), and statistically analyzed (SPSS Statistics 24, IBM). RESULTS: Volume loss of the natural antagonists decreased in the following order: 106-µm-grit diamond-finished zirconia (4.6 ± 2.5 mm3), glazed 106-µm-grit diamond-finished zirconia (3.8 ± 1.1 mm3), glazed as-sintered zirconia (3.5 ± 0.9 mm3), 46-µm-grit diamond-finished zirconia (1.7 ± 0.6 mm3), control (1.6 ± 0.7 mm3), glazed polished zirconia (1.4 ± 0.5 mm3), and solely polishing (0.4 ± 0.2 mm3). Even when polishing the surfaces before glazing, volume loss was not mitigated to the same extent as after polishing alone. CONCLUSIONS: The zirconia surface condition beneath the glazing influences antagonist wear. Although polishing before glazing resulted in acceptable levels of antagonist wear, this approach did not yield as favorable results as polishing alone. CLINICAL RELEVANCE: For operators favoring glazing, pre-polishing the zirconia surface could be advantageous to reduce wear.


Asunto(s)
Esmalte Dental , Boca Edéntula , Circonio , Humanos , Simulación por Computador , Diamante , Masticación
18.
Clin Oral Investig ; 28(1): 94, 2024 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-38221600

RESUMEN

OBJECTIVES: The aim of this study was to compare failure load and initial damage in monolithic, partially veneered, and completely veneered (translucent) zirconia cantilevered fixed partial dentures (CFPDs), as well as completely veneered metal-ceramic CFPDs under different support and loading configurations. MATERIALS AND METHODS: Eight test groups with anatomically congruent CFPDs (n = 8/group) were fabricated, differing in CFPD material/support structure/loading direction (load applied via steel ball (Ø 6 mm) 3 mm from the distal end of the pontic for axial loading with a 2-point contact on the inner cusp ridges of the buccal and oral cusps and 1.3 mm below the oral cusp tip for 30° oblique loading): (1) monolithic zirconia/CoCr abutment teeth/axial, (2) monolithic zirconia/CoCr abutment teeth/oblique, (3) partially veneered zirconia/CoCr abutment teeth/axial, (4) partially veneered zirconia/CoCr abutment teeth/oblique, (5) completely veneered zirconia/CoCr abutment teeth/axial, (6) completely veneered CoCr/CoCr abutment teeth/axial (control group), (7) partially veneered zirconia/implants/axial, and (8) partially veneered zirconia/natural teeth/axial. Restorations were artificially aged before failure testing. Statistical analysis was conducted using one-way ANOVA and Tukey post hoc tests. RESULTS: Mean failure loads ranged from 392 N (group 8) to 1181 N (group 1). Axially loaded monolithic zirconia CFPDs (group 1) and controls (group 6) showed significantly higher failure loads. Oblique loading significantly reduced failure loads for monolithic zirconia CFPDs (group 2). Initial damage was observed in all groups except monolithic zirconia groups, and fractography revealed design flaws (sharp edges at the occlusal boundary of the veneering window) in partially veneered zirconia CFPDs. CONCLUSIONS: Monolithic zirconia CFPDs might be a viable alternative to completely veneered CoCr CFPDs in terms of fracture load. However, oblique loading of monolithic zirconia CFPDs should be avoided in clinical scenarios. Design improvements are required for partially veneered zirconia CFPDs to enhance their load-bearing capacity. CLINICAL RELEVANCE: Monolithic zirconia may represent a viable all-ceramic alternative to the established metal-ceramic option for CFPD fabrication. However, in daily clinical practice, careful occlusal adjustment and regular monitoring should ensure that oblique loading of the cantilever is avoided.


Asunto(s)
Cerámica , Fracaso de la Restauración Dental , Circonio , Dentadura Parcial Fija , Porcelana Dental , Ensayo de Materiales , Análisis del Estrés Dental , Coronas
19.
Odontology ; 2024 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-38717525

RESUMEN

The purpose of this study was to analyze the biomechanical properties of implants made of different materials to replace missing teeth by using three-dimensional finite element analysis and provide a theoretic basis for clinical application. CBCT data was imported into the Mimics and 3-Matic to construct the three-dimensional finite element model of a missing tooth restored by an implant. Then, the model was imported into the Marc Mentat. Based on the variations of the implant materials (titanium, titanium-zirconia, zirconia and poly (ether-ether-ketone) (PEEK)) and bone densities (high and low), a total of eight models were created. An axial load of 150 N was applied to the crown of the implant to simulate the actual occlusal situation. Both the maximum values of stresses in the cortical bone and implant were observed in the Zr-low model. The maximum displacements of the implants were also within the normal range except for the PEEK models. The cancellous bone strains were mainly distributed in the apical area of the implant, and the maximum value (3225 µstrain) was found in PEEK-low model. Under the premise of the same implant material, the relevant data from various indices in low-density bone models were larger than that in high-density bone models. From the biomechanical point of view, zirconia, titanium and titanium-zirconia were all acceptable implant materials for replacing missing teeth and possessed excellent mechanical properties, while the application of PEEK material needs to be further optimized and modified.

20.
Odontology ; 112(1): 169-176, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37422770

RESUMEN

The aim of this study is to evaluate the effect of pre-ceramic soldering on the marginal and internal fit of 4-unit zirconia fixed dental prostheses (FPDs) that have two abutments and two pontics. 4-unit zirconia frameworks (Zirkonzahn ICE Translucent) (Z Group) and monolithic zirconia (Zirkonzahn Prettau) (M Group) FPDs were manufactured. Groups were divided into two groups (n = 10) control (ZC and MC) and soldering (ZS and MS). Samples of ZS and MS groups were cut into two pieces under cooling water and soldered with a bonding material (DCM Zircon HotBond). The marginal and internal fit of the restorations were measured from 36 points of each sample and cement space volume was calculated using reverse engineering software (Geomagic Design X). The mean and standard deviations were submitted to Generalized Linear Mixed Model (GLMM) analysis (α = 0.05). Statistical differences between groups before and after pre-ceramic soldering on point measurements were found. In total cement spacing measurements, a significant difference was found amongst all groups (P < 0.05). However, in premolars, a statistically significant difference was found between ZC and ZS groups and MC and MS groups (P < 0.05). All discrepancies after pre-ceramic soldering were found to be lower than before.


Asunto(s)
Porcelana Dental , Prótesis Dental , Porcelana Dental/química , Cerámica/química , Materiales Dentales/química , Circonio/química , Cementos Dentales , Cementos de Ionómero Vítreo , Adaptación Marginal Dental , Dentadura Parcial Fija , Diseño Asistido por Computadora
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA