Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Tipo de documento
País/Região como assunto
Intervalo de ano de publicação
1.
Chemosphere ; 351: 141146, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38211792

RESUMO

Recent ecotoxicological studies have indicated mercury (Hg) contamination in aquatic ecosystems in the Amazon Basin. Although Hg contamination can be associated with small-scale gold mining, the soils of the Amazon region have naturally high Hg concentrations, and can be transported to aquatic ecosystems via deforestation and mining activities. Biomagnification of Hg can pose risks to the local human population; therefore, its concentration in fish tissues must be monitored consistently. Fast and sensitive Hg determination is required for continuously monitoring ecosystems impacted by mineral exploration. The direct mercury analyzer (DMA-80) is widely used for determining total Hg levels in tissue samples; it is fast and cost-effective, without requiring sample preparation. Here, we determined the sensitivity and specificity of Hg detection accomplished using DMA-80, and whether these results are reliable compared to those obtained using Inductively Coupled Plasma Mass Spectrometer (ICP-MS), which is the gold standard. We obtained 106 paired dried samples of muscle tissue from fish species occupying different trophic levels in the Lower Amazon region, and analyzed them using both equipment (DMA-80 and ICP-MS). The results obtained using DMA-80 had an overall Hg mean of 1.90 ± 0.18 mg/kg which was higher (p < 0.05) than the mean of those obtained using ICP-MS (1.55 ± 0.13 mg/kg). Linear regression analysis comparing the Hg levels obtained using both devices was within the 95% prediction interval, and a high coefficient of correlation showed agreement between the devices (r = 0.979; 0.069 to 0.986, 95% CI). Bland-Altman analysis showed that DMA-80 had a positive bias of 6.5% in relation to ICP-MS, which is more evident in samples with high Hg concentrations. DMA-80 was efficient in determining whether the Hg levels exceeded the maximum allowed levels required by the European Union, USA, and Brazil, showing a specificity and sensitivity of above 95%.


Assuntos
Mercúrio , Animais , Humanos , Mercúrio/análise , Ecossistema , Sensibilidade e Especificidade , Peixes , Espectrometria de Massas , Monitoramento Ambiental
2.
J Xenobiot ; 14(3): 1093-1108, 2024 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-39189177

RESUMO

Previous studies have found inconsistent associations between heavy metals and metalloids (cadmium, lead, mercury, and arsenic), and reproductive outcomes. The biofluid concentrations of ten non-essential trace elements (Hg, Pb, As, Ba, Sr, Rb, Cs, Sn, Ni, and Co) were evaluated in 51 Spanish women undergoing ICSI, PGT-A, and SET/FET. Nine out of ten non-essential elements were detectable in follicular fluid, whole blood, and urine collected the day of vaginal oocyte retrieval (VOR) and the day of embryo transfer and then analyzed by ICP-MS or Tricell DMA-80 for mercury. Elevated mercury and strontium concentrations in follicular fluid were associated with poor ovarian response and preimplantation outcomes. Worst preimplantation outcomes were also identified in women with elevated whole-blood strontium or mercury, urinary arsenic, barium, and tin the day of VOR. High concentrations of urinary rubidium on VOR day were linked with enhanced fertilization and blastocyst development. Excessive titanium in whole blood was associated with lower odds of implantation, clinical pregnancy, and achieving a live birth in a given IVF cycle. Excessive urinary arsenic on the day of embryo transfer was associated with lower odds of live birth. Although these preliminary results need to be confirmed in larger populations, distinguishing organic and inorganic element forms, our findings show that some non-essential elements have a detrimental impact on human IVF outcomes.

3.
Toxics ; 11(4)2023 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-37112544

RESUMO

The meat of snails can be considered a high-quality food for the human diet and demand is already increasing across Europe. Due to the bioaccumulation of trace elements in their tissues, land snails can be a significant tool also for environmental pollution evaluation. In this study, 28 mineral elements (Ag, Al, As, B, Ba, Be, Bi, Cd, Co, Cr, Cu, Fe, Hg, K, Li, Na, Mg, Mn, Mo, Ni, Pb, Sb, Se, Sr, Ti, Tl, V, Zn) in both the edible part and the shell of edible land snails commercially available in Southern Italy belonging to Cernuella virgata, Helix aperta, Theba pisana species were investigated by ICP-MS and direct mercury analyser. The concentration of trace elements was variable among the samples. The variability demonstrates the close connection among the type of snail, the geographical origin, and the habitat in which the species grows. The edible part of the snails analysed in this study was found to be a good source of macro-nutrients. Toxic elements were detected in some samples, especially in shells; nevertheless, the values fell within the safety limits. Further investigations and monitoring of mineral contents in edible land snails are suggested both for human health and environmental pollution evaluation.

4.
Animals (Basel) ; 13(15)2023 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-37570283

RESUMO

Biomonitoring is the qualitative observation and the measurement of biosphere parameters aimed at modelling the environment, evaluating its quality, and studying the effects of alterations on different ecological levels. In this work, trace metal concentrations were assessed using non-destructive biomonitoring tools as blood and feathers of the allochthonous aquatic bird Cairina moschata, collected within two areas of the Palermo metropolitan area, Sicily, differently exposed to air pollution: Parco D'Orleans, in a central urban location, and Monreale, southwest of the city centre. Higher concentrations in both blood and feathers collected in Parco D' Orleans were found for lead, tin and selenium, but the same was not observed for other metals. The concentrations were not above physiological tolerance in any case. The comparison between blood and feathers allowed to realize that the latter are more useful for biomonitoring analyses, as they are indicative of both external contamination and bioaccumulation. Treatment with nitric acid highlighted that the feathers collected in Parco D' Orleans had higher metal bioaccumulation than the ones collected in Monreale; however, the treatment needs standardization. The present study confirms that feathers and blood from C. moschata are a convenient and non-destructive sampling tool for metal contamination analysis.

5.
Environ Sci Pollut Res Int ; 29(20): 30486-30495, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35000156

RESUMO

Multielement concentrations (P, S, Cl, K, Ca, Cr, Mn, Fe, Ni, Cu, Zn, Rb, and Rh) and total mercury (T-Hg) were analyzed in different organs and tissues of Amazonian manatee (Trichechus inunguis). Samples of 27 T. inunguis specimens, maintained in the collection of the Amazonian Center for the Research and Preservation of Aquatic Mammals, were used, situated in an area highly impacted by gold mining in the northern region of the Brazilian Amazon. Samples of aquatic plants used as food by the animals were also analyzed. The elements S, Cl, K, Cr, and Mn accumulated mainly in the musculature, while Fe and Cu were more concentrated in the liver. Trace elements, such as rubidium (Rb) and rhodium (Rh), not previously reported in the organs of animals of the family Trichechidae, were also identified. The averages for T-Hg in the skin, muscle, encephalon, liver, kidney, and lung samples were, respectively, 0.1540 ± 0.1332, 0.0593 ± 0.1044, 0.0517 ± 0.0467, 0.0486 ± 0.0543, 0.0237 ± 0.0336, and 0.0013 ± 0.0032 µg.g-1. The values obtained for the vibrissae samples were below the limit of quantification, which allows for the conclusion that this tissue cannot be used as a contamination marker. It was observed that even when kept in a conservation breeding site, these animals were exposed to non-essential trace elements. Differences in the accumulation of elements were observed between the different organs and tissues analyzed. The presence of contaminants in animals that live in a preservation center, even at low levels, deserves attention.


Assuntos
Mercúrio , Oligoelementos , Trichechus inunguis , Animais , Brasil , Mamíferos , Trichechus inunguis/fisiologia
6.
Foods ; 9(11)2020 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-33198149

RESUMO

There is a lack of scientific evidence regarding the stability of iodine and mercury during cooking and processing of seafood. In this study, the iodine and mercury content were determined after thawing frozen fillets of Atlantic cod (Cadus morhua), and further in raw compared to boiled, pan-fried, and oven baked fillets. Iodine was determined by Inductively Coupled Plasma-Mass Spectrometry (ICP-MS) and mercury by atomic absorption spectrophotometry with Direct Mercury Analyzer (DMA-80). Thawing of the cod resulted on average in a 12% loss of iodine to the thawing water. Boiling significantly decreased the total content of iodine per slice of cod fillet corresponding to the concentration of iodine found in the boiling water. Pan-frying and oven-baking did not cause any significant changes of the total iodine content per slice of cod fillet, although iodine content per 100 g increased due to weight reduction of the cod slices from evaporation of water during preparation. For mercury, we found minimal changes of the different cooking methods. In summary, the findings in our study show that boiling had the greatest effect on the iodine content in the cod fillets. Type of cooking method should be specified in food composition databases as this in turn may influence estimation of iodine intake.

7.
Food Sci Nutr ; 4(3): 398-408, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27247770

RESUMO

The aim of the present study was to evaluate the chemical quality parameters regarding frozen Pangasius hypophthalmus specimens from Vietnam. The proximate composition, pH, ammonia, biogenic amines (BAs), total mercury (Hg), malondialdehyde (MDA), and polyphosphate were determined. The moisture, protein, lipid and ash values were between 83.83-85.59, 12.51-14.52, 1.09-1.65, and 0.76-2.38 g 100 g(-1), respectively. Fraud by excessive polyphosphate addition was detected in 30% of the samples whereas Hg above the recommended limit was observed in 50% of the samples. With regard to compounds from the degradation process, low concentrations of individual BAs and pH values were found in this study and ranged from 5.88 to 6.18, except for samples with polyphosphate >1 g 100(-1) (pH > 7.00) were observed in the present study. However, ammonia concentration indicated that a degradation process initiated in 80% of the samples (0.12-0.34 NH 3 g(-1)) and 20% of the samples (1.87-1.94 µg NH 3 g(-1)) were in an advanced deterioration process. Furthermore, MDA values (1.21-7.88 mg kg(-1)) suggested some failures, mainly during transportation and/or storage. We concluded that quality control measures must be implemented on the Pangasius production chain to improve the quality of products provided to consumers worldwide.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA