Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Year range
1.
J. bras. nefrol ; 44(1): 32-41, Jan-Mar. 2022. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1365039

ABSTRACT

Abstract Introduction: Monitoring water quality in mobile dialysis (MD) services, assessing critical points and characterizing the risks inherent in the process, is essential to avoid risks to the patient's health. This study evaluated the microbiological quality of water in the MD of 36 hospitals with intensive treatment in the city of Rio de Janeiro. Methods: 204 water samples were collected from the points of entry to the network (NET), post-osmosis (PO) and dialysis solution (DS). The samples were evaluated for heterotrophic bacteria count, pathogen search, presence of endotoxins and aluminum content. Results: Bacterial contamination at 3 collection points in 36 hospitals was 30% (32/108); 42% from DS, 31% from PO and 17% from NET, with the presence of Pseudomonas aeruginosa, Stenotrophomonas maltophilia , Burkholderia cepacia and Ralstonia pickettii in the 3 points. Endotoxin concentrations above 0.25 EU/mL occurred in 77% of the samples (17/22) analyzed in the PO. In the aluminum content, values above 0.01 mg/L were presented in 47% (7/15) of PO samples and 27% (4/15) of NET samples. There is no specific legislation for water used in the MD; therefore, the limits of the RDC of the National Health Surveillance Agency (Anvisa) 11/2014 were used; which regulates conventional hemodialysis services. Conclusion: The results highlight the importance of evaluating water quality in MD services to ensure patient safety and support the sanitary monitoring of this process as a healthcare promoter.


Resumo Introdução: Monitorar a qualidade da água nos serviços de diálise móvel (DM), avaliando os pontos críticos e caracterizando os riscos inerentes ao processo, é fundamental para evitar riscos à saúde do paciente. Este estudo avaliou a qualidade microbiológica da água na DM de 36 hospitais com tratamento intensivo no município do Rio de Janeiro. Métodos: Foram coletadas 204 amostras de água dos pontos de entrada da rede (REDE), pós-osmose (PO) e solução de diálise (SD). As amostras foram avaliadas quanto à contagem de bactérias heterotróficas, pesquisa de patógenos, presença de endotoxinas e teor de alumínio. Resultados: A contaminação bacteriana, em 3 pontos de coleta nos 36 hospitais, foi de 30% (32/108), sendo 42% provenientes da SD, 31% da PO e 17% da REDE, com presença de Pseudomonas aeruginosa, Stenotrophomonas maltophilia, Burkholderia cepacia e Ralstonia pickettii nos 3 pontos. Concentrações de endotoxina acima de 0,25 EU/mL ocorreram em 77% das amostras (17/22) analisadas na PO. No teor de alumínio, os valores acima de 0,01 mg/L foram apresentados em 47% (7/15) das amostras da PO e 27% (4/15) das amostras da REDE. Não existe uma legislação específica para água utilizada na DM; logo, foram utilizados os limites da RDC da Agência Nacional de Vigilância Sanitária (Anvisa) 11/2014, que regulamenta os serviços de hemodiálise convencional. Conclusão: Os resultados ressaltam a importância da avaliação da qualidade da água nos serviços de DM para garantir a segurança do paciente e subsidiar o monitoramento sanitário desse processo como um promotor de saúde.

2.
J. bras. nefrol ; 36(4): 502-511, Oct-Dec/2014. tab, graf
Article in Portuguese | LILACS | ID: lil-731153

ABSTRACT

Introdução: São escassos estudos dos custos dos insumos consumidos em hemodiálise e, dentre estes gastos, os compostos que compõem o dialisato estão entre os valores considerados como representativos nessa terapia. Contudo, não foram encontrados estudos que orientem sobre o comportamento de custos dessas soluções. Objetivo: O objetivo do artigo é avaliar se há desperdício no consumo de soluções alcalinas em hemodiálise ambulatorial e, consequentemente, a possibilidade de redução no custo a partir da simulação de padronização no processo de estabelecimento do fluxo do dialisato nos períodos entre turnos em sessões de hemodiálise ambulatorial. Métodos: Partindo de um estudo observacional analítico, foi realizada uma simulação de 20 cenários, sendo 10 estabelecidos pela padronização dos processos de controle no fluxo do dialisato nos intervalos das sessões. A combinação dos dados foi realizada tomando por base os preços de três fornecedores de soluções alcalinas líquidas ou em pó. Resultados: Observou-se, dentre os cenários com processos padronizados, uma variação entre 7,7% e 33,3% de economia no custo da solução alcalina (em pó ou líquida), pela redução do desperdício. Conclusão: É possível refrear o desperdício no uso de soluções alcalinas, tanto em pó quanto líquidas e, consequentemente, seus custos, a partir da padronização na redução do fluxo de dialisato durante os intervalos verificados entre os turnos na hemodiálise ambulatorial. Todavia, estes resultados estão condicionados ao comprometimento de profissionais de saúde, principalmente no que tange ao exercício da supervisão e controle das atividades ...


Introduction: There are few studies about costs of inputs used in hemodialysis and among these expenditures, the compounds that make up the dialysate are one of the values considered as representative of this therapy. However, there aren’t costs studies that guiding solutions. Objective: The objective of this article is discuss whether there is wasteful of alkaline solutions in ambulatory hemodialysis and hence the possibility of reduction in cost from the standardization process simulation of establishment of dialysate flow in periods between shifts in hemodialysis outpatients. Methods: Starting from an observational analytic, a simulation was performed twenty case scenarios, which ten cases established by standardizing processes control on the dialysate flow in recession. The combination of data was performed using as a basis the prices of three suppliers of alkali liquid or powder. Results: It was observed among the scenarios with standardized processes, ranging between 7.7% and 33.3% savings in the alkaline solution cost (powder or liquid), by reducing waste. Conclusion: It is possible to restrain the wasteful use of alkaline solutions, both powder and liquid. Consequently, its cost from the patterning on reducing the flow of dialysate during the intervals between shifts observed in the outpatient hemodialysis. However, these results are conditional upon the commitment of health professionals, mainly to supervision exercise and control of activities in quality function deployment. .


Subject(s)
Fusarium/metabolism , Gold/metabolism , Chlorides/metabolism , Gold Compounds/metabolism , Intercellular Junctions , Microspheres , Nanotechnology
3.
J. bras. nefrol ; 34(4): 323-327, out.-dez. 2012. tab
Article in Portuguese | LILACS | ID: lil-660544

ABSTRACT

INTRODUÇÃO: Hipoglicemia pode ocorrer durante hemodiálise em pacientes diabéticos renais crônicos quando se utiliza dialisato sem glicose. Com soluções de diálise contendo glicose a 90 mg/dL ou mais, isto pode ser prevenido, mas esses pacientes diabéticos podem apresentar glicemias intradialíticas muito elevadas. OBJETIVO: Nosso estudo testou um dialisato com taxas mais reduzidas de glicose tentando prevenir tanto hipo como hiperglicemia nesses pacientes. MÉTODOS: Vinte indivíduos diabéticos de nossa unidade de hemodiálise foram submetidos a três sessões com soluções de diálise com diferentes concentrações de glicose - 55 mg/dL (Fase 55) e 90 mg/dL (Fase 90) - e uma solução sem glicose (Fase ZERO). Glicemias foram medidas em cinco momentos durante cada sessão - antes e aos 30, 60, 150 e 240 min. Resultados inferiores a 70 mg/dL foram considerados como hipoglicemia. RESULTADOS: Três pacientes apresentaram seis episódios de hipoglicemia na Fase 55, mas nenhum paciente apresentou qualquer episódio na Fase 90. Na Fase ZERO, cinco pacientes apresentaram sete episódios. CONCLUSÃO: O dialisato com baixo teor de glicose (55 mg/dL) não preveniu episódios de hipoglicemia durante hemodiálise em pacientes diabéticos, um achado similar ao obtido quando se utilizou solução de diálise sem glicose. O uso de dialisato com glicose a 90 mg/dL não produziu glicemias intradialíticas mais elevadas do que as outras soluções de diálise.


INTRODUCTION: Hypoglycemia can occur during hemodialysis in diabetic chronic renal failure patients when using a dialysate without glucose. With dialysis solutions with glucose 90 mg/dL or more, this is preventable, but diabetic patients could present higher intradialytic glycemias. OBJECTIVE: We tested a dialytic fluid with a lower level of glucose trying to prevent both hypo and hyperglycemia in these patients. METHODS: Twenty diabetic individuals from our hemodialysis unit were submitted to 3 sessions with dialysis solutions with two different glucose concentrations - 55 mg/dL (Phase 55), and 90 mg/dL (Phase 90) - and a glucose-free one (Phase ZERO). Plasma glucose levels were measured at five moments during each session - before and at 30, 60, 90 and 240 min. Results under 70 mg/dL were considered as hypoglycemia. RESULTS: Three patients presented 6 episodes of hypoglycemia in Phase 55, but no patient presented any episode in Phase 90. In Phase ZERO, five patients presented 7 episodes. CONCLUSION: This dialysate with a low level of glucose (55 mg/dL) did not prevent hypoglycemia episodes during hemodialysis in diabetic patients, these occurrences being similar to that when using a dialysate without glucose. The use of a 90 mg/dL glucose dialysis solution did not induce higher intradialytic glycemia levels than the other dialysis solutions.


Subject(s)
Female , Humans , Male , Middle Aged , Blood Glucose/analysis , Diabetes Mellitus/blood , Dialysis Solutions/chemistry , Glucose/analysis , Hypoglycemia/epidemiology , Renal Dialysis , Risk Factors , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL