Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters

Database
Language
Affiliation country
Publication year range
1.
Nano Lett ; 10(8): 3204-8, 2010 Aug 11.
Article in English | MEDLINE | ID: mdl-20698638

ABSTRACT

In this paper we demonstrate that under ultrahigh strain conditions p-type single crystal silicon nanowires possess an anomalous piezoresistance effect. The measurements were performed on vapor-liquid-solid (VLS) grown Si nanowires, monolithically integrated in a microelectro-mechanical loading module. The special setup enables the application of pure uniaxial tensile strain along the <111> growth direction of individual, 100 nm thick Si nanowires while simultaneously measuring the resistance of the nanowires. For low strain levels (nanowire elongation less than 0.8%), our measurements revealed the expected positive piezoresistance effect, whereas for ultrahigh strain levels a transition to anomalous negative piezoresistance was observed. For the maximum tensile strain of 3.5%, the resistance of the Si nanowires decreased by a factor of 10. Even at these high strain amplitudes, no fatigue failures are observed for several hundred loading cycles. The ability to fabricate single-crystal nanowires that are widely free of structural defects will it make possible to apply high strain without fracturing to other materials as well, therefore in any application where crystallinity and strain are important, the idea of making nanowires should be of a high value.

2.
Nano Lett ; 9(5): 1830-4, 2009 May.
Article in English | MEDLINE | ID: mdl-19323479

ABSTRACT

In this letter, we demonstrate the simultaneous vertical integration of self-contacting and highly oriented nanowires (NWs) into airbridge structures, which have been developed into surround gated metal oxide semiconductor field effect transistors (MOSFETs). With the use of conventional photolithography, reactive ion etching (RIE), and low pressure chemical vapor deposition, a suspended vertical NW architecture is formed on a silicon on insulator (SOI) substrate where the nanodevice will later be fabricated on. The vapor-liquid-solid (VLS) grown Si-NWs are contacted to prepatterned airbridges by a self-aligned process, and there is no need for postgrowth NW assembly or alignment. Such vertical NW architecture can be easily integrated into existing ICs processes opening the path to a new generation of nonconventional nano devices. To demonstrate the potential of this method, surround gated vertical MOSFETs have been fabricated with a highly simplified integration scheme combining top-down and bottom-up approaches, but in the same way, one can think about the realization of integrated nano sensors on the industrial scale.

3.
EJNMMI Res ; 6(Suppl 1): 32, 2016 Apr.
Article in English | MEDLINE | ID: mdl-27090254

ABSTRACT

TABLE OF CONTENTS: A1 68Ga-PSMA PET/CT in staging and restaging of Prostate Cancer Patients: comparative study with 18F-Choline PET/CTW Langsteger, A Rezaee, W Loidl, HS Geinitz, F Fitz, M Steinmair, G Broinger, L Pallwien-Prettner, M BeheshtiA2 F18 Choline PET - CT: an accurate diagnostic tool for the detection of parathyroid adenoma?L Imamovic, M Beheshti, G Rendl, D Hackl, O Tsybrovsky, M Steinmair, K Emmanuel, F Moinfar, C Pirich, W LangstegerA3 [18F]Fluoro-DOPA-PET/CT in the primary diagnosis of medullary thyroid carcinomaA Bytyqi, G Karanikas, M Mayerhöfer, O Koperek, B Niederle, M HartenbachA4 Variations of clinical PET/MR operations: An international survey on the clinical utilization of PET/MRIT Beyer, K Herrmann, J CzerninA5 Standard Dixon-based attenuation correction in combined PET/MRI: Reproducibility and the possibility of Lean body mass estimationI Rausch, P Rust, MD DiFranco, M Lassen, A Stadlbauer, ME Mayerhöfer, M Hartenbach, M Hacker, T BeyerA6 High resolution digital FDG PET/MRI imaging for assessment of ACL graft viabilityK Binzel, R Magnussen, W Wei, MU Knopp, DC Flanigan, C Kaeding, MV KnoppA7 Using pre-existing hematotoxicity as predictor for severe side effects and number of treatment cycles of Xofigo therapyA Leisser, M Nejabat, M Hartenbach, G Kramer, M Krainer, M Hacker, A HaugA8 QDOSE - comprehensive software solution for internal dose assessmentWencke Lehnert, Karl Schmidt, Sharok Kimiaei, Marcus Bronzel, Andreas KlugeA9 Clinical impact of Time-of-Flight on next-generation digital PET imaging of Yttrium-90 radioactivity following liver radioembolizationCL Wright, K Binzel, J Zhang, Evan Wuthrick, Piotr Maniawski, MV KnoppA10 Snakes in patients! Lessons learned from programming active contours for automated organ segmentationM Blaickner, E Rados, A Huber, M Dulovits, H Kulkarni, S Wiessalla, C Schuchardt, RP Baum, B Knäusl, D GeorgA11 Influence of a genetic polymorphism on brain uptake of the dual ABCB1/ABCG2 substrate [11C]tariquidarM Bauer, B Wulkersdorfer, W Wadsak, C Philippe, H Haslacher, M Zeitlinger, O LangerA12 Outcome prediction of temporal lobe epilepsy surgery from P-glycoprotein activity. Pooled analysis of (R)-[11C]-verapamil PET data from two European centresM Bauer, M Feldmann, R Karch, W Wadsak, M Zeitlinger, MJ Koepp, M-C Asselin, E Pataraia, O LangerA13 In-vitro and in-vivo characterization of [18F]FE@SNAP and derivatives for the visualization of the melanin concentrating hormone receptor 1M Zeilinger, C Philippe, M Dumanic, F Pichler, J Pilz, M Hacker, W Wadsak, M MitterhauserA14 Reducing time in quality control leads to higher specific radioactivity of short-lived radiotracersL Nics, B Steiner, M Hacker, M Mitterhauser, W WadsakA15 In vitro 11C-erlotinib binding experiments in cancer cell lines with epidermal growth factor receptor mutationsA Traxl, Thomas Wanek, Kushtrim Kryeziu, Severin Mairinger, Johann Stanek, Walter Berger, Claudia Kuntner, Oliver LangerA16 7-[11C]methyl-6-bromopurine, a PET tracer to measure brain Mrp1 function: radiosynthesis and first PET evaluation in miceS Mairinger, T Wanek, A Traxl, M Krohn, J Stanek, T Filip, M Sauberer, C Kuntner, J Pahnke, O LangerA17 18F labeled azidoglucose derivatives as "click" agents for pretargeted PET imagingD Svatunek, C Denk, M Wilkovitsch, T Wanek, T Filip, C Kuntner-Hannes, J Fröhlich, H MikulaA18 Bioorthogonal tools for PET imaging: development of radiolabeled 1,2,4,5-TetrazinesC Denk, D Svatunek, T Wanek, S Mairinger, J Stanek, T Filip, J Fröhlich, H Mikula, C Kuntner-HannesA19 Preclinical evaluation of [18F]FE@SUPPY- a new PET-tracer for oncologyT Balber, J Singer, J Fazekas, C Rami-Mark, N Berroterán-Infante, E Jensen-Jarolim, W Wadsak, M Hacker, H Viernstein, M MitterhauserA20 Investigation of Small [18F]-Fluoroalkylazides for Rapid Radiolabeling and In Vivo Click ChemistryC Denk, D Svatunek, B Sohr, H Mikula, J Fröhlich, T Wanek, C Kuntner-Hannes, T FilipA21 Microfluidic 68Ga-radiolabeling of PSMA-HBED-CC using a flow-through reactorS Pfaff, C Philippe, M Mitterhauser, M Hartenbach, M Hacker, W WadsakA22 Influence of 24-nor-ursodeoxycholic acid on hepatic disposition of [18F]ciprofloxacin measured with positron emission tomographyT Wanek, E Halilbasic, M Visentin, S Mairinger, B Stieger, C Kuntner, M Trauner, O LangerA23 Automated 18F-flumazenil production using chemically resistant disposable cassettesP Lam, M Aistleitner, R Eichinger, C ArtnerA24 Similarities and differences in the synthesis and quality control of 177Lu-DOTA-TATE, 177Lu -HA-DOTA-TATE and 177Lu-DOTA-PSMA (PSMA-617)H Eidherr, C Vraka, A Haug, M Mitterhauser, L Nics, M Hartenbach, M Hacker, W WadsakA25 68Ga- and 177Lu-labelling of PSMA-617H Kvaternik, R Müller, D Hausberger, C Zink, RM AignerA26 Radiolabelling of liposomes with 67Ga and biodistribution studies after administration by an aerosol inhalation systemU Cossío, M Asensio, A Montes, S Akhtar, Y te Welscher, R van Nostrum, V Gómez-Vallejo, J LlopA27 Fully automated quantification of DaTscan SPECT: Integration of age and gender differencesF VandeVyver, T Barclay, N Lippens, M TrochA28 Lesion-to-background ratio in co-registered 18F-FET PET/MR imaging - is it a valuable tool to differentiate between low grade and high grade brain tumor?L Hehenwarter, B Egger, J Holzmannhofer, M Rodrigues-Radischat, C PirichA29 [11C]-methionine PET in gliomas - a retrospective data analysis of 166 patientsN Pötsch, I Rausch, D Wilhelm, M Weber, J Furtner, G Karanikas, A Wöhrer, M Mitterhauser, M Hacker, T Traub-WeidingerA30 18F-Fluorocholine versus 18F-Fluorodeoxyglucose for PET/CT imaging in patients with relapsed or progressive multiple myeloma: a pilot studyT Cassou-Mounat, S Balogova, V Nataf, M Calzada, V Huchet, K Kerrou, J-Y Devaux, M Mohty, L Garderet, J-N TalbotA31 Prognostic benefit of additional SPECT/CT in sentinel lymph node mapping of breast cancer patientsS Stanzel, G Pregartner, T Schwarz, V Bjelic-Radisic, B Liegl-Atzwanger, R AignerA32 Evaluation of diagnostic value of TOF-18F-FDG PET/CT in patients with suspected pancreatic cancerS Stanzel, F Quehenberger, RM AignerA33 New quantification method for diagnosis of primary hyperpatahyroidism lesions and differential diagnosis vs thyropid nodular disease in dynamic scintigraphyA Koljevic Markovic, Milica Jankovic, V Miler Jerkovic, M Paskas, G Pupic, R Dzodic, D PopovicA34 A rare case of diffuse pancreatic involvement in patient with merkel cell carcinoma detected by 18F-FDGMC Fornito, D FamiliariA35 TSH-stimulated 18F-FDG PET/CT in the diagnosis of recurrent/metastatic radioiodine-negative differentiated thyroid carcinomas in patients with various thyroglobuline levelsP Koranda, H Polzerová, I Metelková, L Henzlová, R Formánek, E Buriánková, M KamínekA36 Breast Dose from lactation following I131 treatmentWH Thomson, C LewisA37 A new concept for performing SeHCAT studies with the gamma cameraWH Thomson, J O'Brien, G James, A NotghiA38 Whole body F-18-FDG-PET and tuberculosis: sensitivity compared to x-ray-CTH Huber, I Stelzmüller, R Wunn, M Mandl, F Fellner, B Lamprecht, M GabrielA39 Emerging role 18F-FDG PET-CT in the diagnosis and follow-up of the infection in heartware ventricular assist system (HVAD)MC Fornito, G LeonardiA40 Validation of Poisson resampling softwareWH Thomson, J O'Brien, G JamesA41 Protection of PET nuclear medicine personnel: problems in satisfying dose limit requirementsJ Hudzietzová, J Sabol, M Fülöp.

4.
Nanotechnology ; 19(48): 485606, 2008 Dec 03.
Article in English | MEDLINE | ID: mdl-21836307

ABSTRACT

We report on the influence of the surface pretreatment for vapor-liquid-solid growth of epitaxial silicon nanowires with gold catalyst and silane precursor on Si(111) substrates. In this paper we make it obvious that a thin native oxide layer on the Si substrate-as is present under most technological conditions-or a thin layer of oxide formed on top of the catalytic gold particle restrain nucleation and nanowire growth. High resolution transmission electron microscopy, and electron energy loss spectroscopy were utilized to demonstrate Si diffusion from the substrate through the catalytic Au layer and further the formation of a thin oxide layer atop. Based on this observation we present a sample pretreatment practice, making the catalyst insensitive for further oxide formation, thereby preserving epitaxy for nanowire synthesis.

5.
Nano Lett ; 8(8): 2310-4, 2008 Aug.
Article in English | MEDLINE | ID: mdl-18624392

ABSTRACT

Single crystal silicon nanowires (SiNWs) were synthesized with silane reactant using Au nanocluster-catalyzed one-dimensional growth. We have shown that under our experimental conditions, SiNWs grown epitaxially on Si(111) via the vapor-liquid-solid growth mechanism change their growth direction as a function of the total pressure. Structural characterization of a large number of samples shows that SiNWs synthesized at a total pressure of 3 mbar grow preferentially in the 111 direction, while the one at 15 mbar favors the 112 direction. Specifically by dynamically changing the system pressure during the growth process morphological changes of the NW growth directions along their length have been demonstrated.

SELECTION OF CITATIONS
SEARCH DETAIL