Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Pacing Clin Electrophysiol ; 46(9): 1049-1055, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37527153

RESUMEN

BACKGROUND: Intermittent ventricular pre-excitation was considered a low-risk marker for sudden death. However, to date, some studies do not exclude the existence of accessory pathways (APs) with high-risk intermittent antegrade conductive properties. According to current European Guidelines, high-risk features of APs are antegrade pathway conduction ≤250 ms in baseline or during the adrenergic stimulus, inducibility of atrioventricular reciprocating tachycardias (AVRT), inducibility of pre-excited atrial fibrillation (AF), and presence of multiple APs. For all of these transcatheter ablation is recommended. The aim of our study was to evaluate the existence of differences in risk characteristics between patients with intermittent pre-excitation (IPX) and those with persistent pre-excitation (PPX), from a sample of adults with ventricular pre-excitation and symptoms like palpitations. METHODS: 293 adults [IPX: 51 (17.4%); PPX: 242 (82.6%)] underwent electrophysiological study and then catheter ablation of their APs if arrhythmia inducibility (AVRT/AF) was noted, or, conversely, if it was appreciated a fast AP antegrade conduction, in baseline or during intravenous isoproterenol infusion, or if multiple APs were detected. RESULTS: There were no statistically significant differences in demographic characteristics (age and gender), AVRT/AF inducibility, antegrade conductive properties, the prevalence of multiple APs, and APs locations between IPX and PPX patients. CONCLUSIONS: In our study, patients with IPX did not show significant differences in clinical and electrophysiological features versus PPX patients.


Asunto(s)
Fascículo Atrioventricular Accesorio , Fibrilación Atrial , Ablación por Catéter , Síndromes de Preexcitación , Síndrome de Wolff-Parkinson-White , Humanos , Adulto , Fascículo Atrioventricular Accesorio/cirugía , Fibrilación Atrial/cirugía , Factores de Riesgo , Electrocardiografía
2.
Eur Heart J Suppl ; 25(Suppl C): C185-C188, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37125310

RESUMEN

Magnetic resonance (MR) represents a new interesting imaging approach for guiding electrophysiology (EP)-based ablation procedures of atrial flutter and typical atrial fibrillation. This new approach permits to reach good results if compared with conventional EP ablation. Tissue characterization by MR permits to detect cardiac anatomy and pathological substrate like myocardial scars well visualized with late gadolinium enhancement (LGE) sequences. Intra-procedural imaging is useful to real-time follow the catheter during the ablation procedure and at the same time to visualize cardiac anatomy in addition to understanding if the ablation is correctly performed using oedema sequences. Performing cardiac ablations inside an MR room permits to reduce radiation exposure and occupational illnesses.

3.
Eur Heart J Suppl ; 25(Suppl C): C265-C270, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37125279

RESUMEN

Radiofrequency (RF) catheter ablation has become a widely used therapeutic approach. However, long-term results in terms of arrhythmia recurrence are still suboptimal. Cardiac magnetic resonance (CMR) could offer a valuable tool to overcome this limitation, with the possibility of targeting the arrhythmic substrate and evaluating the location, depth, and possible gaps of RF lesions. Moreover, real-time CMR-guided procedures offer a radiation-free approach with an evaluation of anatomical structures, substrates, RF lesions, and possible complications during a single procedure. The first steps in the field have been made with cavotricuspid isthmus ablation, showing similar procedural duration and success rate to standard fluoroscopy-guided procedures, while allowing visualization of anatomic structures and RF lesions. These promising results open the path for further studies in the context of more complex arrhythmias, like atrial fibrillation and ventricular tachycardias. Of note, setting up an interventional CMR (iCMR) centre requires safety and technical standards, mostly related to the need for CMR-compatible equipment and medical staff's educational training. For the cardiac imagers, it is fundamental to provide correct CMR sequences for catheter tracking and guide RF delivery. At the same time, the electrophysiologist needs a rapid interpretation of CMR images during the procedures. The aim of this paper is first to review the logistic and technical aspects of setting up an iCMR suite. Then, we will describe the experience in iCMR-guided flutter ablations of two European centres, Policlinico Casilino in Rome, Italy, and Haga Teaching Hospital in The Hague, the Netherlands.

4.
Eur Heart J Suppl ; 25(Suppl C): C261-C264, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37125307

RESUMEN

Neurocardiogenic syncope, also called vasovagal syncope, represents one of the clinical manifestations of neurally mediated syncopal syndrome. Generally, the prognosis of the cardioinhibitory form of neurocardiogenic syncope is good, but quality of life is seriously compromised in patients who experience severe forms. Drug therapy has not achieved good clinical results and very heterogeneous data come from studies regarding permanent cardiac pacing. In this scenario, the ganglionated plexi ablation has been proposed as an effective and safe method in patients with cardioinhibitory neurocardiogenic syncope, especially in young patients in order to avoid or prolong, as much as possible, the timing of definitive cardiac pacing. Certainly, making this procedure less extensive and limiting the ablation in the right atrium (avoiding the potential complications of a left atrial approach) and at level of anatomical regions of the most important ganglionated plexy, considered 'gateway' of the sino-atrial and atrio-ventricular node function (through the recognition of specific endocardial potentials), could be very advantageous in this clinical scenario. Finally, randomized, multicentre, clinical trials on a large population are needed to better understand which is the best ablation treatment (right-only or bi-atrial) and provide evidence for syncope guidelines.

5.
J Electrocardiol ; 51(2): 175-181, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29174022

RESUMEN

BACKGROUND: Left bundle branch block (LBBB) and left axis deviation (LAD) patients may have poor response to resynchronization therapy (CRT). We sought to assess if LBBB and LAD patients show a specific pattern of mechanical asynchrony. METHODS: CRT candidates with non-ischemic cardiomyopathy and LBBB were categorized as having normal QRS axis (within -30° and +90°) or LAD (within -30° and -90°). Patients underwent tissue Doppler imaging (TDI) to measure time interval between onset of QRS complex and peak systolic velocity in ejection period (Q-peak) at basal segments of septal, inferior, lateral and anterior walls, as expression of local timing of mechanical activation. RESULTS: Thirty patients (mean age 70.6years; 19 males) were included. Mean left ventricular ejection fraction was 0.28±0.06. Mean QRS duration was 172.5±13.9ms. Fifteen patients showed LBBB with LAD (QRS duration 173±14; EF 0.27±0.06). The other 15 patients had LBBB with a normal QRS axis (QRS duration 172±14; EF 0.29±0.05). Among patients with LAD, Q-peak interval was significantly longer at the anterior wall in comparison to each other walls (septal 201±46ms, inferior 242±58ms, lateral 267±45ms, anterior 302±50ms; p<0.0001). Conversely, in patients without LAD Q-peak interval was longer at lateral wall, when compared to each other (septal 228±65ms, inferior 250±64ms, lateral 328±98ms, anterior 291±86ms; p<0.0001). CONCLUSIONS: Patients with heart failure, presenting LBBB and LAD, show a specific pattern of ventricular asynchrony, with latest activation at anterior wall. This finding could affect target vessel selection during CRT procedures in these patients.


Asunto(s)
Bloqueo de Rama/prevención & control , Bloqueo de Rama/fisiopatología , Terapia de Resincronización Cardíaca/métodos , Disfunción Ventricular Izquierda/prevención & control , Disfunción Ventricular Izquierda/fisiopatología , Anciano , Bloqueo de Rama/diagnóstico por imagen , Ecocardiografía Doppler , Femenino , Humanos , Masculino , Resultado del Tratamiento , Disfunción Ventricular Izquierda/diagnóstico por imagen
6.
Indian Pacing Electrophysiol J ; 18(2): 61-67, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29102650

RESUMEN

BACKGROUND: The Amigo® Remote Catheter System is a relatively new robotic system for catheter navigation. This study compared feasibility and safety using Amigo (RCM) versus manual catheter manipulation (MCM) to treat paroxysmal atrial fibrillation (PAF). Contact force (CF) and force-time integral (FTI) values obtained during pulmonary vein isolation (PVI) ablation were compared. METHODS: Forty patients were randomly selected for either RCM (20) or MCM (20). All were studied with the Thermocool® SmartTouch® force-sensing catheter (STc). Contact Force (CF), Force Time Integral (FTI) and procedure-related data, were measured/stored in the CARTO®3. RESULTS: All cases achieved complete PVI without major complications. Mean CF was significantly higher in the RCM group (13.3 ± 7.7 g in RCM vs. 12.04 ± 7.42 g in MCM p < 0.001), as was overall mean FTI (425.6 gs ± 199.6 gs with RCM and 407.5 gs ± 288.0 gs in MCM (p = 0.007) and was more likely to fall into the optimal FTI range (400-1000) using RCM (66.1% versus 49.1%, p < 0.001). FTI was significantly more likely to fall within the optimal range in each PV, as was CF within its optimal range in the right PVs, but trended higher in the left PVs. Freedom from atrial tachyarrhythmia was 90.0% for the RCM and 70.0% for the MCM group (p = 0,12) at 540 days follow-up. CONCLUSIONS: This pilot study suggests that use of the Amigo RCM system, with STc catheter, seems to be safe and effective for PVI ablation in paroxysmal AF patients. A not statistically significant favorable trend was observed for RCM in term of AF-free survival.

7.
Indian Pacing Electrophysiol J ; 18(4): 127-132, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29476904

RESUMEN

BACKGROUND: Third-generation cryoballoon (CB3) is characterized by a 40% shorter distal tip designed to increase the rate of pulmonary veins real-time signal recording in order to measure time necessary to isolate veins, the "Time to effect" (TTE). Few data are currently available on clinical follow up of CB3 treated patients. METHODS: Sixtyeight consecutive patients (mean age 57.8 ±â€¯9.6 years, 48 male) with paroxysmal or persistent atrial fibrillation (AF) were enrolled. Thirthyfour (25 paroxysmal AF) underwent to a 28 mmCB3 pulmonary veins isolation and were compared to 34 treated (21 paroxysmal AF) with 28 mmCB2. RESULTS: CB3 use was correlated to significant increase of the possibility to measure TTE in every treated veins (left superior 82,35% vs 23,53%, left inferior 70,59% vs 38,24%, right superior 58,82% vs 14,71%, right inferior 52,94% vs 17,65%). When it is measured, TTE wasn't different between two groups. Higher nadir temperature was observed in CB3 patients (-39.4 ±â€¯5.2 °C vs -43.0 ±â€¯7.2 °C, p = 0.03). CB3 procedures were shorter (91.4 ±â€¯21.7 vs 110.9 ±â€¯31.8 min, p = 0.018), with a significant reduction in cryoenergy delivery time (24.2 ±â€¯8.5 vs 20.3 ±â€¯6.7 min, p < 0.05), and a significant reduction in left atrium dwell time (59.3 ±â€¯9.8 vs 69.3 ±â€¯10.8 min, p = 0.02, p < 0.05). At one year follow up period the Kaplan-Meier curve didn't show any significant difference in AF-free survival (Log p = 0,49). CONCLUSIONS: Novel CB3 is a useful tool in order to simplify AF cryoballoon ablation when compared to second generation cryoballoon, as observed in our experience. Follow up data seem confirm a clinical CB3 efficacy at least comparable CB2.

8.
Europace ; 19(12): 1911-1921, 2017 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-28520959

RESUMEN

Use of cardiac implantable devices and catheter ablation is steadily increasing in Western countries following the positive results of clinical trials. Despite the advances in scientific knowledge, tools development, and techniques improvement we still have some grey area in the field of electrical therapies for the heart. In particular, several reports highlighted differences both in medical behaviour and procedural outcomes between female and male candidates. Women are referred later for catheter ablation of supraventricular arrhythmias, especially atrial fibrillation, leading to suboptimal results. On the opposite females present greater response to cardiac resynchronization, while the benefit of implantable defibrillator in primary prevention seems to be less pronounced. Differences on aetiology, clinical profile, and development of myocardial scarring are the more plausible causes. This review will discuss all these aspects together with gender-related differences in terms of acute/late complications. We will also provide useful hints on plausible mechanisms and practical procedural aspects.


Asunto(s)
Arritmias Cardíacas/terapia , Ablación por Catéter , Cardioversión Eléctrica , Disparidades en Atención de Salud , Evaluación de Procesos, Atención de Salud , Anciano , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidad , Arritmias Cardíacas/fisiopatología , Terapia de Resincronización Cardíaca/efectos adversos , Terapia de Resincronización Cardíaca/mortalidad , Dispositivos de Terapia de Resincronización Cardíaca , Ablación por Catéter/efectos adversos , Ablación por Catéter/mortalidad , Congresos como Asunto , Desfibriladores Implantables , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/instrumentación , Cardioversión Eléctrica/mortalidad , Femenino , Disparidades en el Estado de Salud , Humanos , Masculino , Persona de Mediana Edad , Factores de Riesgo , Factores Sexuales , Resultado del Tratamiento
9.
Am Heart J ; 167(4): 546-54, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24655704

RESUMEN

BACKGROUND: Cardiac resynchronization therapy (CRT) is ineffective in approximately 30% of recipients, in part due to sub-optimal left ventricular (LV) pacing location. The Quartet LV lead, with 2 additional electrodes proximal to conventional bipolar lead electrodes, enables 10 different pacing configurations at four independent LV locations. In a CRT patient cohort, we sought to evaluate the spectrum of echocardiographic and electrocardiographic response over these 10 configurations, to select the optimal one in each patient. Moreover, we sought to evaluate the 6-months clinical and echocardiographic response to a "tailored approach" in which the optimal LV pacing configuration for CRT was determined by echocardiographic measures, QRSd and pacing capture thresholds. METHODS: Twenty-two consecutive CRT indicated patients were implanted with a quadripolar CRT system (St. Jude Medical). Optimal LV pacing configuration was determined by echocardiographic measures, including velocity time integral (VTI), myocardial performance index (MPI) and mitral regurgitation (MR), and an electrocardiographic measure (QRS duration) during pacing from each of the configurations at pre-discharge. The optimal LV pacing vector was chosen for every patient. Clinical and echocardiographic assessment was repeated after 6 months. RESULTS: Various configurations provided different VTI, MPI, MR and QRSd values. Conventional bipolar vectors (ie, D1-M2, D1-RVc, M2-RVc) were rarely associated with the best echocardiographic improvements and provided significantly worse VTI, MR, MPI, and QRSd values than the best configuration for every patient (P = .005, P = .05 and P = .03 for VTI; P = .01, P = .005 and P = .001 for MPI; P = .003, P = .01 and P = .005 for MR, P > .5, P = .01 and P = .05 for QRSd) Conversely, "unconventional" proximal configurations (ie, making use of P4 and M3 electrodes) were generally characterized by higher acute VTI, MR and MPI improvements. CRT devices were reprogrammed with an "unconventional" LV pacing configuration in 50% of patients. A significant improvement in New York Heart Association class (81%), LV ejection fraction (76%), end-diastolic and end-systolic volumes was observed after 6 months (P = .02, P < .001, P = .02 and P = .003, respectively). CONCLUSIONS: In this study, conventional bipolar vectors of quadripolar-CRT were rarely associated with the best echocardiographic improvements. Quadripolar CRT utilizing optimal LV pacing configuration was associated with a significant improvement in New York Heart Association class and LV ejection fraction after 6 months.


Asunto(s)
Estimulación Cardíaca Artificial/normas , Ecocardiografía/métodos , Insuficiencia Cardíaca/diagnóstico por imagen , Ventrículos Cardíacos/fisiopatología , Función Ventricular Izquierda/fisiología , Anciano , Electrocardiografía , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Humanos , Masculino , Estudios Prospectivos , Resultado del Tratamiento
11.
World J Cardiol ; 16(5): 231-239, 2024 May 26.
Artículo en Inglés | MEDLINE | ID: mdl-38817646

RESUMEN

The use of anticoagulation therapy could prove to be controversial when trying to balance ischemic stroke and intracranial bleeding risks in patients with concurrent cerebral amyloid angiopathy (CAA) and atrial fibrillation (AF). In fact, CAA is an age-related cerebral vasculopathy that predisposes patients to intracerebral hemorrhage. Nevertheless, many AF patients require oral systemic dose-adjusted warfarin, direct oral anticoagulants (such as factor Xa inhibitors) or direct thrombin inhibitors to control often associated with cardioembolic stroke risk. The prevalence of both CAA and AF is expected to rise, due to the aging of the population. This clinical dilemma is becoming increasingly common. In patients with coexisting AF and CAA, the risks/benefits profile of anticoagulant therapy must be assessed for each patient individually due to the lack of a clear-cut consensus with regard to its risks in scientific literature. This review aims to provide an overview of the management of patients with concomitant AF and CAA and proposes the implementation of a risk-based decision-making algorithm.

12.
J Cardiovasc Dev Dis ; 11(4)2024 Apr 17.
Artículo en Inglés | MEDLINE | ID: mdl-38667740

RESUMEN

Heart failure (HF) represents a significant global health challenge that is still responsible for increasing morbidity and mortality despite advancements in pharmacological treatments. This review investigates the effectiveness of non-pharmacological interventions in the management of HF, examining lifestyle measures, physical activity, and the role of some electrical therapies such as catheter ablation, cardiac resynchronization therapy (CRT), and cardiac contractility modulation (CCM). Structured exercise training is a cornerstone in this field, demonstrating terrific improvements in functional status, quality of life, and mortality risk reduction, particularly in patients with HF with reduced ejection fraction (HFrEF). Catheter ablation for atrial fibrillation, premature ventricular beats, and ventricular tachycardia aids in improving left ventricular function by reducing arrhythmic burden. CRT remains a key intervention for selected HF patients, helping achieve left ventricular reverse remodeling and improving symptoms. Additionally, the emerging therapy of CCM provides a novel opportunity for patients who do not meet CRT criteria or are non-responders. Integrating non-pharmacological interventions such as digital health alongside specific medications is key for optimizing outcomes in HF management. It is imperative to tailor approaches to individual patients in this diverse patient population to maximize benefits. Further research is warranted to improve treatment strategies and enhance patient outcomes in HF management.

13.
Eur J Prev Cardiol ; 31(4): 486-495, 2024 Mar 04.
Artículo en Inglés | MEDLINE | ID: mdl-38198223

RESUMEN

AIMS: Right bundle branch block (RBBB) morphology non-sustained ventricular arrhythmias (VAs) have been associated with the presence of non-ischaemic left ventricular scar (NLVS) in athletes. The aim of this cross-sectional study was to identify clinical and electrocardiogram (ECG) predictors of the presence of NLVS in athletes with RBBB VAs. METHODS AND RESULTS: Sixty-four athletes [median age 39 (24-53) years, 79% males] with non-sustained RBBB VAs underwent cardiac magnetic resonance (CMR) with late gadolinium enhancement in order to exclude the presence of a concealed structural heart disease. Thirty-six athletes (56%) showed NLVS at CMR and were assigned to the NLVS positive group, whereas 28 athletes (44%) to the NLVS negative group. Family history of cardiomyopathy and seven different ECG variables were statistically more prevalent in the NLVS positive group. At univariate analysis, seven ECG variables (low QRS voltages in limb leads, negative T waves in inferior leads, negative T waves in limb leads I-aVL, negative T waves in precordial leads V4-V6, presence of left posterior fascicular block, presence of pathologic Q waves, and poor R-wave progression in right precordial leads) proved to be statistically associated with the finding of NLVS; these were grouped together in a score. A score ≥2 was proved to be the optimal cut-off point, identifying NLVS athletes in 92% of cases and showing the best accuracy (86% sensitivity and 100% specificity, respectively). However, a cut-off ≥1 correctly identified all patients with NLVS (absence of false negatives). CONCLUSION: In athletes with RBBB morphology non-sustained VAs, specific ECG abnormalities at 12-lead ECG can help in detecting subjects with NLVS at CMR.


In athletes with right bundle branch block (RBBB) morphology non-sustained ventricular arrhythmias (VAs), the presence of a non-ischaemic left ventricular scar (NLVS) may be highly suspected if one or more of the following electrocardiogram (ECG) characteristics are present at the 12-lead resting ECG: low QRS voltages in limb leads, negative T waves in inferior leads, negative T waves in limb leads I­aVL, negative T waves in precordial leads V4­V6, presence of left posterior fascicular block, presence of pathologic Q waves, and poor R-wave progression in right precordial leads. This score should be externally validated in a larger population of athletes with VAs. In athletes with RBBB morphology non-sustained Vas, attention should be placed on the 12-lead resting ECG to suspect the presence of an NLVS. In athletes with RBBB VAs and the presence of one or more of the identified ECG characteristics, a cardiac magnetic resonance with late gadolinium enhancement is useful to rule out an NLVS.


Asunto(s)
Bloqueo de Rama , Complejos Prematuros Ventriculares , Masculino , Humanos , Adulto , Femenino , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/etiología , Complejos Prematuros Ventriculares/diagnóstico , Complejos Prematuros Ventriculares/etiología , Cicatriz/patología , Medios de Contraste , Estudios Transversales , Gadolinio , Electrocardiografía
14.
Artículo en Inglés | MEDLINE | ID: mdl-38814252

RESUMEN

BACKGROUND: Catheter ablation (CA) of atrial fibrillation is routinely used to obtain rhythm control. Evidence suggest that catheter ablation should be done during uninterrupted oral anticoagulation. METHODS: Italian Registry in the setting of atrial fibrillation ablation with rivaroxaban (IRIS) is an Italian multicenter, non-interventional, prospective study which enrolled 250 consecutive atrial fibrillation patients eligible for catheter ablation on rivaroxaban. The decision for rivaroxaban management was left to the physician: uninterrupted or shortly interrupted prior to Catheter ablation. Patients received a follow-up visit at 1 month and 12 months after the procedure. RESULTS: The primary outcome, represented by all-cause death and systemic embolism at 1 month and 12 months was characterized by one transient ischemic attack and one myocardial infarction in the first 30 days. Both events happened in patients with shortly interrupted strategy (P=0.147), and both in patients who underwent radiofrequency ablation (P=0.737). In the primary safety outcome represented by major bleeding we did not register any event in the 12-month follow-up. The secondary outcome constituted by minor bleeding registered 1 event, after the first 30 days since CA. CONCLUSIONS: IRIS is the biggest real-life data registry regarding CA ablation on rivaroxaban in Italian setting, proving the safety and efficacy of rivaroxaban.

15.
J Cardiovasc Dev Dis ; 10(3)2023 Feb 23.
Artículo en Inglés | MEDLINE | ID: mdl-36975861

RESUMEN

Catecholaminergic Polymorphic Ventricular Tachycardia (CPVT) is a rare electrical genetic disease characterized by ventricular polymorphic tachycardia and/or bidirectional ventricular tachycardia induced by the release of catecholamines caused by intense physical or emotional stress in structurally normal hearts. Mostly, it is caused by mutations in genes that are involved in calcium homeostasis, in particular in the gene encoding for cardiac ryanodine receptor (RyR2). Our observation is the first description of familial CPVT caused by mutation of the RyR2 gene, linked to the complete AV block.

16.
J Cardiovasc Dev Dis ; 10(5)2023 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-37233185

RESUMEN

Atrial fibrillation (AF) is the most common sustained arrhythmia in clinical practice, and it is an enormous burden worldwide because of its high morbidity, disability and mortality. It is generally acknowledged that physical activity (PA) is strongly associated with a significant reduction in the risk of cardiovascular (CV) disease and all-cause mortality. Moreover, it has been observed that moderate and regular physical activity has the potential to reduce the risk of AF, in addition to improving overall well-being. Nevertheless, some studies have associated intense physical activity with an increased risk of AF. This paper aims to review the main related literature to investigate the association between PA and AF incidence and draw pathophysiological and epidemiological conclusions.

17.
J Arrhythm ; 39(1): 18-26, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36733331

RESUMEN

Background: His bundle pacing (HBP) may be a challenging procedure, often involving a long fluoroscopic time (FT) and a long procedural time (PT). We sought to evaluate whether the use of a new nonfluroscopic mapping (NFM) system, the KODEX-EPD, is able to reduce FT and PT when mapping is performed by the pacing catheter rather than an electrophysiological mapping catheter. Methods and Results: We included 46 consecutive patients (77 ± 8 years; 63% male) who underwent HBP; in 22 a NFM-guided procedure with the KODEX-EPD system was performed (group 1), whereas in 24 a conventional fluoroscopy-guided approach was used (group 2). Pacing indications were sick sinus syndrome in 13, atrioventricular block in 21, and cardiac resynchronization therapy in 12 cases. Both a lumen-less fixed helix lead and a stylet-driven extendable helix lead were used, respectively, in 24% and 76% of patients. HBP was successful in 22 patients (100%) in group 1 and 23 patients (96%) in group 2. The FT was significantly reduced in group 1 (183 ± 117 s vs 464.1 ± 352 s in group 2, p = .012). There were no significant differences between groups in PT and other procedural outcomes. Conclusions: The KODEX-EPD system may be safely used in HBP procedures. It is effective in reducing ionizing radiation exposure, as evidenced by the significant drop in FT, without increasing PT.

18.
Front Cardiovasc Med ; 10: 1115328, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37529713

RESUMEN

Aims: Supraventricular tachycardias may trigger atrial fibrillation (AF). The aim of the study was to evaluate the prevalence of supraventricular tachycardia (SVT) inducibility in patients referred for AF ablation and to evaluate the effects of SVT ablation on AF recurrences. Methods and results: 249 patients (mean age: 54 ± 14 years) referred for paroxysmal AF ablation were studied. In all patients, only AF relapses had been documented in the clinical history. 47 patients (19%; mean age: 42 ± 11 years) had inducible SVT during the electrophysiological study and underwent an ablation targeted only at SVT suppression. Ablation was successful in all 47 patients. The ablative procedures were: 11 slow-pathway ablations for atrioventricular nodal re-entrant tachycardia; 6 concealed accessory pathway ablations for atrioventricular re-entrant tachycardia; 17 focal ectopic atrial tachycardia ablations; 13 with only one arrhythmogenic pulmonary vein. No recurrences of SVT were observed during the follow-up (32 ± 18 months). 4 patients (8.5%) showed recurrence of at least one episode of AF. Patients with inducible SVT had less structural heart disease and were younger than those without inducible SVT. Conclusion: A significant proportion of candidates for AF ablation are inducible for an SVT. SVT ablation showed a preventive effect on AF recurrences. Those patients should be selected for simpler ablation procedures tailored only to the triggering arrhythmia suppression.

19.
Minerva Cardiol Angiol ; 71(1): 91-99, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35080355

RESUMEN

BACKGROUND: Catheter ablation (CA) of atrial fibrillation (AF) is used routinely to establish rhythm control. There is mounting evidence that CA procedures should be performed during continuous oral anticoagulation and direct oral anticoagulants (DOACs) are considered the first anticoagulation strategy. Few real-life data are now available and even less in the Italian panorama. METHODS: IRIS is an Italian multicenter, non-interventional, prospective study which will be enrolled consecutive AF patients eligible for CA and treated with Rivaroxaban; patients in treatment with Rivaroxaban proceeded directly to CA while Rivaroxaban-naive patients were scheduled for CA after 4 weeks of uninterrupted anticoagulation unless the exclusion of atrial thrombi. Rivaroxaban was uninterrupted or shortly uninterrupted (<24 hours) prior CA, in line with routinely practice of each operator. Patients will be followed on continuous anticoagulation for 1 month after the ablation. The primary efficacy outcome is the cumulative incidence of all-cause death and systemic embolism while the primary safety outcome is the incidence of major bleeding events. The secondary outcomes are represented by non-major bleeding events. All events must be occurred within the first 30 days after the procedure. RESULTS: Two hundred fifty patients are expected to be enrolled and the study is estimated to be completed by the end of 2022. Up to now 56 patients have been enrolled. CONCLUSIONS: This study is the first large Italian prospective study on the management of Rivaroxaban in patients undergoing CA of AF. It aims to depict a comprehensive view of anticoagulation strategy prior CA in several Italian electrophysiology labs.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Rivaroxabán/efectos adversos , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/cirugía , Estudios Prospectivos , Inhibidores del Factor Xa/efectos adversos , Resultado del Tratamiento , Hemorragia/inducido químicamente , Hemorragia/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Sistema de Registros
20.
Pacing Clin Electrophysiol ; 35(8): 927-34, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22651702

RESUMEN

BACKGROUND: Cardiac resynchronization therapy (CRT) has proved to be very effective in improving morbidity and mortality in patients affected with severe congestive heart failure. Its efficacy has been shown to be greater in patients with left bundle branch block (LBBB). The aim of our study was to verify if newly proposed criteria for true LBBB identify patients with a better clinical and instrumental response to CRT. METHODS: Between May 2007 and April 2011, 111 patients with left ventricular ejection fraction (LVEF) ≤ 35% and LBBB morphology received a CRT device and were divided into two groups according to QRS morphology. Group 1 (61 patients) consisted of patients with "true" LBBB morphology; group 2 (50 patients) consisted of patients with "false" LBBB. The primary endpoint was the utility of criteria for true LBBB to predict a composite endpoint of all-cause mortality and hospital admission with heart failure. The secondary endpoint was the utility of the same criteria to predict an absolute increase in LVEF ≥ 10%. RESULTS: "False" LBBB morphology and a dose of bisoprolol <5 mg at last follow-up were the only parameters related to clinical outcome in multivariate analysis (respectively: hazard ratio [HR] 3.98, confidence interval [CI] 95% 1.51-10.48; HR 0.15, CI 95% 0.05-0.43). "True" LBBB morphology was the only variable significantly related to a greater increase in LVEF (HR 4.57, CI 95% 1.36-8.28). CONCLUSION: True LBBB morphology is related to a higher event-free survival rate in CRT patients and better echocardiographic response.


Asunto(s)
Bloqueo de Rama/diagnóstico , Bloqueo de Rama/terapia , Terapia de Resincronización Cardíaca , Electrocardiografía/métodos , Anciano , Anciano de 80 o más Años , Antihipertensivos/uso terapéutico , Bisoprolol/uso terapéutico , Bloqueo de Rama/mortalidad , Supervivencia sin Enfermedad , Electrocardiografía/instrumentación , Femenino , Insuficiencia Cardíaca/tratamiento farmacológico , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/terapia , Humanos , Masculino , Persona de Mediana Edad , Índice de Severidad de la Enfermedad , Volumen Sistólico/fisiología , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA