RESUMEN
BACKGROUND: Physical activity can cause glucose fluctuations both during and after it is performed, leading to hurdles in optimal insulin dosing in people with type 1 diabetes (T1D). We conducted a pilot clinical trial assessing the safety and feasibility of a physical activity-informed mealtime insulin bolus advisor that adjusts the meal bolus according to previous physical activity, based on step count data collected through an off-the-shelf physical activity tracker. METHODS: Fifteen adults with T1D, each using a continuous glucose monitor (CGM) and an insulin pump with carbohydrate counting, completed two randomized crossover daily visits. Participants performed a 30 to 45-minute brisk walk before lunch and lunchtime insulin boluses were calculated based on either their standard therapy (ST) or the physical activity-informed bolus method. Post-lunch glycemic excursions were assessed using CGM readings. RESULTS: There was no significant difference between visits in the time spent in hypoglycemia in the post-lunch period (median [IQR] standard: 0 [0]% vs physical activity-informed: 0 [0]%, P = NS). Standard therapy bolus yielded a higher time spent in 70 to 180 mg/dL target range (mean ± standard: 77% ± 27% vs physical activity-informed: 59% ± 31%, P = .03) yet, it was associated with a steeper negative slope in the early postprandial phase (P = .032). CONCLUSIONS: Use of step count to adjust mealtime insulin following a walking bout has proved to be safe and feasible in a cohort of 15 T1D subjects. Physical activity-informed insulin dosing of meals eaten soon after a walking bout has a potential of mitigating physical activity related glucose reduction in the early postprandial phase.
Asunto(s)
Diabetes Mellitus Tipo 1 , Adulto , Glucemia , Estudios Cruzados , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Estudios de Factibilidad , Glucosa , Humanos , Hipoglucemiantes , Insulina , Sistemas de Infusión de Insulina , Comidas , Proyectos Piloto , Periodo PosprandialRESUMEN
Background: Use of sodium-glucose cotransporter 2 inhibitors (SGLT2i) as adjunct therapy to insulin in type 1 diabetes (T1D) has been previously studied. In this study, we present data from the first free-living trial combining low-dose SGLT2i with commercial automated insulin delivery (AID) or predictive low glucose suspend (PLGS) systems. Methods: In an 8-week, randomized, controlled crossover trial, adults with T1D received 5 mg/day empagliflozin (EMPA) or no drug (NOEMPA) as adjunct to insulin therapy. Participants were also randomized to sequential orders of AID (Control-IQ) and PLGS (Basal-IQ) systems for 4 and 2 weeks, respectively. The primary endpoint was percent time-in-range (TIR) 70-180 mg/dL during daytime (7:00-23:00 h) while on AID (NCT04201496). Findings: A total of 39 subjects were enrolled, 35 were randomized, 34 (EMPA; n = 18 and NOEMPA n = 16) were analyzed according to the intention-to-treat principle, and 32 (EMPA; n = 16 and NOEMPA n = 16) completed the trial. On AID, EMPA versus NOEMPA had higher daytime TIR 81% versus 71% with a mean estimated difference of +9.9% (confidence interval [95% CI] 0.6-19.1); p = 0.04. On PLGS, the EMPA versus NOEMPA daytime TIR was 80% versus 63%, mean estimated difference of +16.5% (95% CI 7.3-25.7); p < 0.001. One subject on SGLT2i and AID had one episode of diabetic ketoacidosis with nonfunctioning insulin pump infusion site occlusion contributory. Interpretation: In an 8-week outpatient study, addition of 5 mg daily empagliflozin to commercially available AID or PLGS systems significantly improved daytime glucose control in individuals with T1D, without increased hypoglycemia risk. However, the risk of ketosis and ketoacidosis remains. Therefore, future studies with SGLT2i will need modifications to closed-loop control algorithms to enhance safety.
Asunto(s)
Diabetes Mellitus Tipo 1 , Adulto , Glucemia , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Glucosa , Humanos , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Sistemas de Infusión de Insulina , Insulina Regular Humana/uso terapéuticoRESUMEN
OBJECTIVE: Continuous glucose monitoring (CGM) improves diabetes management, but its reliability in individuals on hemodialysis is poorly understood and potentially affected by interstitial and intravascular volume variations. RESEARCH DESIGN AND METHODS: We assessed the accuracy of a factory-calibrated CGM by using venous blood glucose measurements (vBGM) during hemodialysis sessions and self-monitoring blood glucose (SMBG) at home. RESULTS: Twenty participants completed the protocol. The mean absolute relative difference of the CGM was 13.8% and 14.4%, when calculated on SMBG (n = 684) and on vBGM (n = 624), and 98.7% and 100% of values in the Parkes error grid A/B zones, respectively. Throughout 181 days of CGM monitoring, the median time in range (70-180 mg/dL) was 38.5% (interquartile range 29.3-57.9), with 28.7% (7.8-40.6) of the time >250 mg/dL. CONCLUSIONS: The overall performance of a factory-calibrated CGM appears reasonably accurate and clinically relevant for use in practice by individuals on hemodialysis and health professionals to improve diabetes management.
Asunto(s)
Glucemia , Diabetes Mellitus Tipo 1 , Automonitorización de la Glucosa Sanguínea/métodos , Humanos , Diálisis Renal , Reproducibilidad de los ResultadosRESUMEN
Objective: To assess the safety and efficacy of a simplified initialization for the Tandem t:slim X2 Control-IQ hybrid closed-loop system, using parameters based on total daily insulin ("MyTDI") in adolescents with type 1 diabetes under usual activity and during periods of increased exercise. Research Design and Methods: Adolescents with type 1 diabetes 12-18 years of age used Control-IQ for 5 days at home using their usual parameters. Upon arrival at a 60-h ski camp, participants were randomized to either continue Control-IQ using their home settings or to reinitialize Control-IQ with MyTDI parameters. Control-IQ use continued for 5 days following camp. The effect of MyTDI on continuous glucose monitoring outcomes were analyzed using repeated measures analysis of variance (ANOVA): baseline, camp, and at home. Results: Twenty participants were enrolled and completed the study; two participants were excluded from the analysis due to absence from ski camp (1) and illness (1). Time in range was similar between both groups at home and camp. A tendency to higher time <70 mg/dL in the MyTDI group was present but only during camp (median 3.8% vs. 1.4%, P = 0.057). MyTDI users with bolus/TDI ratios >40% tended to show greater time in the euglycemic range improvements between baseline and home than users with ratios <40% (+16.3% vs. -9.0%, P = 0.012). All participants maintained an average of 95% time in closed loop (84.1%-100%). Conclusions: MyTDI is a safe, effective, and easy way to determine insulin parameters for use in the Control-IQ artificial pancreas. Future modifications to account for the influence of carbohydrate intake on MyTDI calculations might further improve time in range.