Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 67
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Eur Radiol ; 33(5): 3510-3520, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36651956

RESUMEN

OBJECTIVES: To evaluate anatomical and volumetric predictability of a cone beam computed tomography (CBCT)-based virtual parenchymal perfusion (VPP) software for the single-photon-emission computed tomography (SPECT)/CT imaging results during the work-up for transarterial radioembolization (TARE) procedure in patients with hepatocellular carcinoma (HCC). METHODS: VPP was evaluated retrospectively on CBCT data of patients treated by TARE for HCC. 99mTc macroaggregated albumin particles (99mTc-MAA) uptake territories on work-up SPECT/CT was used as ground truth for the evaluation. Semi-quantitative evaluation consisted of the ranking of visual consistency of the parenchymal enhancement and portal vein tumoral involvement on VPP and 99mTc-MAA SPECT/CT, using a three-rank scale and two-rank scale, respectively. Inter-reader agreement was evaluated using a kappa coefficient. Quantitative evaluation included absolute volume error calculation and Pearson correlation between volumes enhanced territories on VPP and 99mTc-MAA SPECT/CT. RESULTS: Fifty-two CBCTs were performed in 33 included patients. Semi-quantitative evaluation showed a good concordance between actual 99mTc-MAA uptake and the virtual enhanced territories in 73% and 75% of cases; a mild concordance in 12% and 10% and a poor concordance in 15%, for the two readers. Kappa coefficient was 0.86. Portal vein involvement evaluation showed a good concordance in 58.3% and 66.7% for the two readers, respectively, with a kappa coefficient of 0.82. Quantitative evaluation showed a volume error of 0.46 ± 0.78 mL [0.01-3.55], and Pearson R2 factor at 0.75 with a p value < 0.01. CONCLUSION: CBCT-based VPP software is accurate and reliable to predict 99mTc-MAA SPECT/CT anatomical and volumetric results in HCC patients during TARE. KEY POINTS: • Virtual parenchymal perfusion (VPP) software is accurate and reliable in the prediction of 99mTc-MAA SPECT volumetric and targeting results in HCC patients during transarterial radioembolization (TARE). • VPP software may be used per-operatively to optimize the microcatheter position for 90Y infusion allowing precise tumor targeting while preserving non-tumoral parenchyma. • Post-operatively, VPP software may allow an accurate estimation of the perfused volume by each arterial branch and, thus, a precise 90Y dosimetry for TARE procedures.


Asunto(s)
Carcinoma Hepatocelular , Embolización Terapéutica , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/radioterapia , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/radioterapia , Estudios Retrospectivos , Reproducibilidad de los Resultados , Agregado de Albúmina Marcado con Tecnecio Tc 99m , Radioisótopos de Itrio , Tomografía Computarizada de Emisión de Fotón Único/métodos , Tomografía Computarizada por Rayos X/métodos , Tomografía Computarizada de Haz Cónico , Embolización Terapéutica/métodos , Algoritmos , Programas Informáticos , Perfusión , Microesferas
2.
AJR Am J Roentgenol ; 218(2): 359-369, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34494448

RESUMEN

BACKGROUND. Assessment of hepatocellular carcinoma (HCC) treatment response after transarterial radioembolization (TARE) is challenging, because response by conventional imaging criteria may not become apparent until 6 months after treatment. Though HCC exhibits variable avidity for FDG, some cases of HCC without avidity for FDG show avidity for 18F-fluorocholine (18F-FCH). OBJECTIVE. The purpose of this study was to evaluate the utility of early posttreatment evaluation by PET/CT using FDG or 18F-FCH to predict 6-month treatment response and survival after TARE in patients with HCC. METHODS. This retrospective study included 37 patients (mean age, 67 years; 34 men, three women) with documented HCC treated by TARE who underwent both pre-treatment FDG PET/CT and 18F-FCH PET/CT and early FDG PET/CT and/or 18F-FCH PET/CT 4-8 weeks after treatment; FDG PET/CT and 18F-FCH PET/CT examinations were performed on separate dates. Only one of 73 initially identified potentially eligible patients was excluded because of lack of HCC avidity for both FDG and 18F-FCH. Response assessment by modified RECIST (mRECIST) on multiphase CT or MRI was performed at 1 month and 6 months in 23 patients. Early responses seen on PET/CT and 1-month mRECIST response were assessed as predictors of 6-month mRECIST response. Univariable and multivariable predictors of overall survival (OS) were identified. RESULTS. On pretreatment PET/CT, 28 (76%) patients were FDG-positive (showed visual uptake on FDG PET/CT and tumor-to-normal liver ratio > 1.15), 15 (41%) were FCH-positive (showed visual uptake on 18F-FCH PET/CT), and six (16%) were both FDG-positive and FCH-positive. Twelve of 28 FDG-positive HCCs exhibited early response by FDG PET/CT; seven of 15 FCH-positive HCCs exhibited early response by 18F-FCH PET/CT. Twelve (52%) patients exhibited 6-month mRECIST response. Response seen on early posttreatment PET/CT exhibited 100% (12/12) sensitivity and 100% (11/11) specificity for 6-month mRECIST response, whereas 1-month mRECIST response exhibited 67% (8/12) sensitivity and 100% (11/11) specificity for 6-month mRECIST response. Response seen on early posttreatment PET/CT was a significant independent predictor of OS on univariable (hazard ratio [HR], 0.4; 95% CI, 0.2-0.9; p = .03) and multivariable (HR, 0.2; 95% CI, 0.1-0.8; p = .01) analyses. CONCLUSION. Early evaluation after TARE by PET/CT using FDG or 18F-FCH may pre dict 6-month response and OS in patients with HCC. CLINICAL IMPACT. Early posttreatment evaluation with PET/CT could help more reliably identify true nonresponders after TARE, which in turn could prompt early response-adapted therapeutic management.


Asunto(s)
Braquiterapia/métodos , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/radioterapia , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/radioterapia , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Radiofármacos , Anciano , Colina/análogos & derivados , Femenino , Fluorodesoxiglucosa F18 , Humanos , Hígado/diagnóstico por imagen , Masculino , Estudios Retrospectivos , Resultado del Tratamiento , Radioisótopos de Itrio/administración & dosificación
3.
Radiology ; 300(2): 326-335, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34100681

RESUMEN

Background CT can provide information regarding myocardial perfusion and expansion of the extracellular space, which is relevant to patients with cardiac amyloidosis (CA). Purpose To evaluate the role of CT in the diagnosis and prognosis of CA. Materials and Methods In this prospective study (Commission National de l'Informatique et des Libertés registration no. 1431858), participants with CA, participants with nonamyloid cardiac hypertrophy (NACH), and participants without hypertrophy were included between April 2017 and December 2018. The confirmed diagnosis of CA was determined according to established criteria (ie, proven with positive bone scintigraphy or endomyocardial biopsy). All participants were imaged with dynamic CT perfusion imaging at whole-heart cardiac CT. Extracellular volume measured at CT and myocardial perfusion parameters calculated on CT perfusion maps were compared among different participant groups. Differences between continuous data were tested using the unpaired t test, Mann-Whitney rank-sum test, or the Kruskal-Wallis test. Results A total of 84 participants with CA, 43 participants with NACH, and 33 participants without hypertrophy were included. Participants with CA exhibited a higher value of extracellular volume measured at CT (mean, 54.7% ± 9.7 [standard deviation]) than participants with NACH (mean, 34.6% ± 9.1; P < .001) and participants without hypertrophy (mean, 35.9% ± 9.9; P = .001). Mean myocardial blood volume and mean myocardial blood flow were lower in participants with CA (mean myocardial blood volume: 4.05 mL/100 g of myocardium ± 0.80; mean myocardial blood flow: 73.2 mL/100 g of myocardium per minute ± 25.7) compared to participants with NACH (mean myocardial blood volume: 5.38 mL/100 g of myocardium ± 1.20, P < .001; mean myocardial blood flow: 89.6 mL/100 g of myocardium per minute ± 31.3, P = .007) and participants without hypertrophy (mean myocardial blood volume: 5.68 mL/100 g of myocardium ± 1.05; mean myocardial blood flow: 106.3 mL/100 g of myocardium per minute ± 29.8; P < .001 for both). Extracellular volume measured at CT (hazard ratio >0.56 vs ≤0.56 = 4.2 [95% CI: 1.4, 11.8]), mean slope (hazard ratio ≤3.0 sec-1 vs >3.0 sec-1 = 0.2 [95% CI: 0.1, 0.8]), and time to peak (hazard ratio >20 seconds vs ≤20 seconds = 11.6 [95% CI: 1.3, 101.6]) were predictive of mortality in participants with CA. Conclusion Participants with cardiac amyloidosis exhibited an increase in extracellular volume at CT and abnormal CT perfusion parameters. Extracellular volume and several perfusion parameters were predictive of mortality. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Zimmerman in this issue.


Asunto(s)
Amiloidosis/diagnóstico por imagen , Cardiomiopatías/diagnóstico por imagen , Imagen de Perfusión Miocárdica , Tomografía Computarizada por Rayos X , Anciano , Biomarcadores/sangre , Ecocardiografía , Femenino , Humanos , Masculino , Estudios Prospectivos
4.
Eur J Vasc Endovasc Surg ; 62(2): 204-213, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33994306

RESUMEN

OBJECTIVE: The aim was to describe initial outcomes of physician modified stent grafts using antegrade laser fenestrations and image fusion guidance (LEVAR) and company manufactured custom made (CM) stent grafts for the treatment of complex abdominal aortic aneurysms (CAAAs), thoraco-abdominal aortic aneurysms (TAAAs) and type I endoleaks (T1ELs). METHODS: This was a retrospective single centre study. All LEVAR and Zenith (Cook) CM stent graft procedures between 1 January 2012 and 31 December 2018 were reviewed. Endpoints included intra-operative adverse events (IOAEs), in hospital mortality, re-interventions, target vessel patency, and 12 month outcomes (overall survival, freedom from re-intervention, target vessel patency). Outcomes at 12 months were estimated using the Kaplan-Meier method. RESULTS: A hundred patients were identified and included in the study. All patients were deemed unfit for open repair. The cohort included 22 LEVAR and 78 CM stent grafts. LEVAR cases included painful aneurysms (n = 5), > 65 mm aneurysms (n = 10), anatomical constrains and/or presence of previous renal stents (n = 7) or cases declined by the manufacturer planning centre (n = 2). IOAEs were recorded in 41% of cases (n = 9) in the LEVAR group vs. 10% (n = 8, p = .002) in the CM group. The in hospital mortality rate in the LEVAR group was 9% (n = 2) vs. 4% (n = 3, p = .30) in the CM group. The median follow up duration was 22 months (7 - 38) in the LEVAR group and 28 months (11 - 78) in the CM group. The estimate of overall survival at one year was 91% in both groups. The freedom from re-intervention rate at one year was 58% in the LEVAR group vs. 87% in the CM group. The target vessel patency rates at one year were 95% in both groups. CONCLUSION: In high risk patients deemed unfit for open repair, LEVAR may provide satisfactory 12 month overall survival and target vessel patency rates, though reported IOAE, mortality, and re-interventions rates were high thus requiring close and extensive follow up.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Torácica/cirugía , Prótesis Vascular , Endofuga/cirugía , Procedimientos Endovasculares/instrumentación , Anciano , Anciano de 80 o más Años , Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/efectos adversos , Tomografía Computarizada de Haz Cónico , Endofuga/etiología , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/métodos , Femenino , Fluoroscopía , Mortalidad Hospitalaria , Humanos , Complicaciones Intraoperatorias/etiología , Terapia por Láser , Masculino , Persona de Mediana Edad , Imagen Multimodal , Complicaciones Posoperatorias/etiología , Reoperación , Estudios Retrospectivos , Stents/efectos adversos , Cirugía Asistida por Computador , Tasa de Supervivencia , Grado de Desobstrucción Vascular
5.
J Nucl Cardiol ; 28(4): 1586-1595, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31512197

RESUMEN

BACKGROUND: We evaluated the diagnostic performance of 18F-NaF PET/MRI in patients with suspected cardiac amyloidosis (CA). METHODS: Twenty-seven consecutive patients underwent myocardial PET 1 hour after injection of 4 MBq/kg 18F-NaF with simultaneous MRI including cine-MRI, T1 and T2 mapping, first-pass and late gadolinium enhancement (LGE). 18F-NaF uptake was measured visually and semi-quantitatively by calculating myocardium-to-blood pool (M/B) ratios. CA was confirmed histologically. RESULTS: Transthyretin (TTR)-CA was diagnosed in 16 patients, light-chain (AL)-CA in 7, and no-CA in 4. Visual interpretation of 18F-NaF images revealed a relative increase in myocardial uptake in only 3 patients, all with TTR CA, and a relative decrease in 13, including 7 AL CA, 3 no-CA, and 3 TTR CA. M/B ratios were significantly higher in TTR CA (1.00 ± 0.12) than in AL CA (0.81 ± 0.06, P = 0.001) or in no-CA (0.73 ± 0.16, P = 0.006). The optimal M/B cut-off to distinguish TTR CA from AL CA was ≥ 0.90 (Fischer, P = 0.0005). By comparison, classification of patients using 99mTc-HMDP heart-to-mediastinum ratios with the previously published cut-off ≥ 1.21 reached higher significance (P < 0.0001). Among MRI parameters, myocardial T1, LGE score, and extracellular volume were higher in CA than in no-CA patients, 1409 ± 76 vs 1278 ± 35 ms (P = 0.004), 10.35 ± 5.30 vs 3.50 ± 3.42 (P = 0.03), and 46 ± 10 vs 33 ± 8 % (P = 0.01), respectively. CONCLUSION: 18F-NaF PET/MRI shows good diagnostic performance when semi-quantification is used. However, contrast is low and visual interpretation may be challenging in routine. PET/MRI could constitute a one-stop-shop evaluation of amyloid load and cardiac function in patients needing rapid work-up.


Asunto(s)
Amiloidosis/diagnóstico por imagen , Cardiomiopatías/diagnóstico por imagen , Imagen por Resonancia Magnética , Imagen de Perfusión Miocárdica , Tomografía de Emisión de Positrones , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Cohortes , Femenino , Radioisótopos de Flúor , Humanos , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad , Fluoruro de Sodio
6.
Ann Vasc Surg ; 71: 533.e7-533.e12, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32927040

RESUMEN

BACKGROUND: We report a case of juxtarenal abdominal aortic aneurysm-anatomically unsuitable for conventional endovascular repair because of narrow distal aorta-successfully treated by endovascular repair facilitated by in situ laser fenestration. METHODS AND RESULTS: An aortic stent graft was inserted to exclude a juxtarenal aneurysm: under image fusion guidance, antegrade in situ laser fenestration allowed to perfuse superior mesenteric artery and both renal arteries. After complementary insertion of an extended aortouni-iliac stent graft, retrograde in situ laser fenestration was performed to perfuse the contralateral left iliac artery, in order to overcome a narrow distal aorta. Postoperative course was uneventful. Six month's CT showed an excluded aneurysm, patency of the inserted stents and the absence of endoleak. CONCLUSIONS: In situ laser fenestration seems to be an effective solution for endovascular therapy of complex juxtarenal aneurysms. In this case of narrow distal aorta it was a suitable alternative to overcome endovascular aneurysm repair anatomical restrictions and to prevent other additional open surgical interventions.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Stents , Anciano , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/fisiopatología , Humanos , Masculino , Diseño de Prótesis , Flujo Sanguíneo Regional , Resultado del Tratamiento , Grado de Desobstrucción Vascular
7.
Radiology ; 295(3): 562-571, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32228294

RESUMEN

Background The recently described "macrotrabecular-massive" (MTM) histologic subtype of hepatocellular carcinoma (HCC) (MTM-HCC) represents an aggressive form of HCC and is associated with poor survival. Purpose To investigate whether preoperative MRI can help identify MTM-HCCs in patients with HCC. Materials and Methods This retrospective study included patients with HCC treated with surgical resection between January 2008 and February 2018 and who underwent preoperative multiphase contrast material-enhanced MRI. Least absolute shrinkage and selection operator (LASSO)-penalized and multivariable logistic regression analyses were performed to identify clinical, biologic, and imaging features associated with the MTM-HCC subtype. Early recurrence (within 2 years) and overall recurrence were evaluated by using Kaplan-Meier analysis. Multivariable Cox regression analysis was performed to determine predictors of early and overall recurrence. Results One hundred fifty-two patients (median age, 64 years; interquartile range, 56-72 years; 126 men) with 152 HCCs were evaluated. Twenty-six of the 152 HCCs (17%) were MTM-HCCs. LASSO-penalized logistic regression analysis identified substantial necrosis, high serum α-fetoprotein (AFP) level (>100 ng/mL), and Barcelona Clinic Liver Cancer (BCLC) stage B or C as independent features associated with MTM-HCCs. At multivariable analysis, substantial necrosis (odds ratio = 32; 95% confidence interval [CI] = 8.9, 114; P < .001), high serum AFP level (odds ratio = 4.4; 95% CI = 1.3, 16; P = .02), and BCLC stage B or C (odds ratio = 4.2; 95% CI = 1.2, 15; P = .03) were independent predictors of MTM-HCC subtype. Substantial necrosis helped identify 65% (17 of 26; 95% CI: 44%, 83%) of MTM-HCCs (sensitivity) with a specificity of 93% (117 of 126; 95% CI: 87%, 97%). In adjusted models, only the presence of satellite nodules was independently associated with both early (hazard ratio = 3.7; 95% CI: 1.5, 9.4; P = .006) and overall (hazard ratio = 3.0; 95% CI: 1.3, 7.2; P = .01) tumor recurrence. Conclusion At multiphase contrast-enhanced MRI, substantial necrosis helped identify macrotrabecular-massive hepatocellular carcinoma subtype with high specificity. © RSNA, 2020.


Asunto(s)
Carcinoma Hepatocelular/diagnóstico por imagen , Neoplasias Hepáticas/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Anciano , Carcinoma Hepatocelular/clasificación , Carcinoma Hepatocelular/patología , Femenino , Humanos , Aumento de la Imagen/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Estimación de Kaplan-Meier , Hígado/diagnóstico por imagen , Hígado/patología , Neoplasias Hepáticas/clasificación , Neoplasias Hepáticas/patología , Masculino , Persona de Mediana Edad , Recurrencia Local de Neoplasia/clasificación , Recurrencia Local de Neoplasia/diagnóstico por imagen , Recurrencia Local de Neoplasia/patología , Pronóstico , Estudios Retrospectivos , Sensibilidad y Especificidad
8.
Eur Radiol ; 30(2): 925-926, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31802214

RESUMEN

KEY POINTS: • Robotic assistance in medicine has been a revolution.• The use of robots has naturally extended to interventional radiology for percutaneous and endovascular interventions.• The guidance is mainly performed with a remote (computer or joystick) allowing the operator and his team not to be exposed to X-rays.


Asunto(s)
Radiología Intervencionista/métodos , Procedimientos Quirúrgicos Robotizados/métodos , Humanos , Masculino , Procedimientos Quirúrgicos Vasculares/métodos
9.
Eur Radiol ; 30(10): 5348-5357, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32405753

RESUMEN

OBJECTIVES: To compare the performance of the quantitative analysis of the hepatobiliary phase (HBP) tumor enhancement in gadobenate dimeglumine (Gd-BOPTA)-enhanced MRI and of dual-tracer 18F-FDG and 18F-fluorocholine (FCH) PET/CT for the prediction of tumor aggressiveness and recurrence-free survival (RFS) in resectable hepatocellular carcinoma (HCC). METHODS: This retrospective, IRB approved study included 32 patients with 35 surgically proven HCCs. All patients underwent Gd-BOPTA-enhanced MRI including delayed HBP images, 18F-FDG PET/CT, and (for 29/32 patients) 18F-FCH PET/CT during the 2 months prior to surgery. For each lesion, the lesion-to-liver contrast enhancement ratio (LLCER) on MRI HBP images and the SUVmax tumor-to-liver ratio (SUVT/L) for both tracers were calculated. Their predictive value for aggressive pathological features-including the histological grade and microvascular invasion (MVI)-and RFS were analyzed and compared using area under receiver operating characteristic (AUROC) curves and Cox regression models, respectively. RESULTS: The AUROCs for the identification of aggressive HCCs on pathology with LLCER, 18F-FDG SUVT/L, and 18F-FCH SUVT/L were 0.92 (95% CI 0.78, 0.98), 0.89 (95% CI 0.74, 0.97; p = 0.70), and 0.64 (95% CI 0.45, 0.80; p = 0.035). At multivariate Cox regression analysis, LLCER was identified as an independent predictor of RFS (HR (95% CI) = 0.91 (0.84, 0.99), p = 0.022). LLCER - 4.72% or less also accurately predicted moderate-poor differentiation grade (Se = 100%, Sp = 92.9%) and MVI (Se = 93.3%, Sp = 60%) and identified patients with poor RFS after surgical resection (p = 0.030). CONCLUSIONS: HBP tumor enhancement after Gd-BOPTA injection may help identify aggressive HCC pathological features, and patients with reduced recurrence-free survival after surgical resection. KEY POINTS: • In patients with resectable HCC, the quantitative analysis of the HBP tumor enhancement in Gd-BOPTA-enhanced MRI (LLCER) accurately identifies moderately-poorly differentiated and/or MVI-positive HCCs. • After surgical resection for HCC, patients with LLCER - 4.72% or less had significantly poorer recurrence-free survival than patients with LLCER superior to - 4.72%. • Gd-BOPTA-enhanced MRI with delayed HBP images may be suggested as part of pre-surgery workup in patients with resectable HCC.


Asunto(s)
Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/patología , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/patología , Imagen por Resonancia Magnética/métodos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Adulto , Anciano , Anciano de 80 o más Años , Carcinoma Hepatocelular/mortalidad , Carcinoma Hepatocelular/cirugía , Colina/análogos & derivados , Medios de Contraste , Supervivencia sin Enfermedad , Femenino , Radioisótopos de Flúor , Fluorodesoxiglucosa F18 , Humanos , Neoplasias Hepáticas/mortalidad , Neoplasias Hepáticas/cirugía , Masculino , Meglumina/análogos & derivados , Persona de Mediana Edad , Estadificación de Neoplasias , Compuestos Organometálicos , Radiofármacos , Recurrencia , Estudios Retrospectivos
10.
Radiology ; 286(2): 560-567, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-28985135

RESUMEN

Purpose To analyze the frequency and distribution of low-signal-intensity regions (LSIRs) in lymphoma lesions and to compare these to fluorodeoxyglucose (FDG) uptake and biologic markers of inflammation. Materials and Methods The authors analyzed 61 untreated patients with a bulky lymphoma (at least one tumor mass ≥7 cm in diameter). When a LSIR within tumor lesions was detected on diffusion-weighted images obtained with a b value of 50 sec/mm2, a T2-weighted gradient-echo (GRE) sequence was performed and calcifications were searched for with computed tomography (CT). In two patients, Perls staining was performed on tissue samples from the LSIR. LSIRs were compared with biologic inflammatory parameters and baseline FDG positon emission tomography (PET)/CT parameters (maximum standardized uptake value [SUVmax], total metabolic tumor volume [TMTV]). Results LSIRs were detected in 22 patients and corresponded to signal void on GRE images; one LSIR was due to calcifications, and three LSIRS were due to a recent biopsy. In 18 patients, LSIRs appeared to be related to focal iron deposits; this was proven with Perls staining in two patients. The LSIRs presumed to be due to iron deposits were found mostly in patients with aggressive lymphoma (nine of 26 patients with Hodgkin lymphoma and eight of 20 patients with diffuse large B-cell lymphoma vs one of 15 patients with follicular lymphoma; P = .047) and with advanced stage disease (15 of 18 patients). LSIRS were observed in spleen (n = 14), liver (n = 3), and nodal (n = 8) lesions and corresponded to foci FDG uptake, with mean SUVmax of 9.8, 6.7, and 16.2, respectively. These patients had significantly higher serum levels of C-reactive protein, α1-globulin, and α2-globulin and more frequently had microcytic anemia than those without such deposits (P = .0072, P = .003, P = .0068, and P < .0001, respectively). They also had a significantly higher TMTV (P = .0055) and higher levels of spleen involvement (P < .0001). Conclusion LSIRs due to focal iron deposits are detected in lymphoma lesions and are associated with a more pronounced biologic inflammatory syndrome. © RSNA, 2017 Online supplemental material is available for this article.


Asunto(s)
Enfermedad de Hodgkin/patología , Hierro/metabolismo , Linfoma Folicular/patología , Linfoma de Células B Grandes Difuso/patología , Adolescente , Adulto , Anciano , Biomarcadores/metabolismo , Imagen de Difusión por Resonancia Magnética , Femenino , Fluorodesoxiglucosa F18/farmacocinética , Humanos , Inflamación/metabolismo , Inflamación/patología , Ganglios Linfáticos/metabolismo , Masculino , Persona de Mediana Edad , Imagen Multimodal , Tomografía Computarizada por Tomografía de Emisión de Positrones , Estudios Prospectivos , Radiofármacos/farmacocinética , Adulto Joven
11.
Eur Radiol ; 28(2): 816-823, 2018 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-28812126

RESUMEN

OBJECTIVE: To measure myocardium iodine concentration (MIC) in patients with cardiac amyloidosis (CA) using dual-energy computed tomography (DECT). METHODS: Twenty-two patients with CA, 13 with non-amyloid hypertrophic cardiomyopathies (CH) and 10 control patients were explored with pre-contrast, arterial and 5-minute DECT acquisition (Iomeprol; 1.5 mL/kg). Inter-ventricular septum (IVS) thickness, blood pool iodine concentration (BPIC), MIC (mg/mL), iodine ratio and extra-cellular volume (ECV) were calculated. RESULTS: IVS thickness was significantly (p < 0.001) higher in CA (17 ± 4 mm) and CH (15 ± 3 mm) patients than in control patients (10 ± 1 mm). CA patients exhibited significantly (p < 0.001) higher 5-minute MIC [2.6 (2.3-3.1) mg/mL], 5-minute iodine ratio (0.88 ± 0.12) and ECV (0.56 ± 0.07) than CH [1.7 (1.4-2.2) mg/mL, 0.57 ± 0.07 and 0.36 ± 0.05, respectively] and control patients [1.9 (1.7-2.4) mg/mL, 0.58 ± 0.07 and 0.35 ± 0.04, respectively). CH and control patients exhibited similar values (p = 0.9). The area under the curve of 5-minute iodine ratio for the differential diagnosis of CA from CH patients was 0.99 (0.73-1.0; p = 0.001). With a threshold of 0.65, the sensitivity and specificity of 5-minute iodine ratio were 100% and 92%, respectively. CONCLUSION: Five-minute MIC and iodine ratio were increased in CA patients and exhibited best diagnosis performance to diagnose CA in comparison to other parameters. KEY POINT: • Dual-energy computed tomography can be used to detect cardiac amyloidosis • Five-minute myocardial iodine concentration and iodine ratio increase in cardiac amyloidosis • Among iodine parameters, 5-minute iodine ratio has the best diagnosis performance.


Asunto(s)
Amiloidosis/diagnóstico por imagen , Cardiomiopatías/diagnóstico por imagen , Yodo/metabolismo , Miocardio/metabolismo , Tomografía Computarizada por Rayos X/métodos , Anciano , Amiloidosis/metabolismo , Cardiomiopatías/metabolismo , Cardiomiopatía Hipertrófica/diagnóstico por imagen , Femenino , Humanos , Masculino , Proyectos Piloto , Interpretación de Imagen Radiográfica Asistida por Computador
12.
Eur Radiol ; 28(5): 1977-1985, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29168007

RESUMEN

OBJECTIVES: To determine the degree of relationship between iodine concentrations derived from dual-energy CT (DECT) and perfusion CT parameters in patients with advanced HCC under treatment. METHODS: In this single-centre IRB approved study, 16 patients with advanced HCC treated with sorafenib or radioembolization who underwent concurrent dynamic perfusion CT and multiphase DECT using a single source, fast kV switching DECT scanner were included. Written informed consent was obtained for all patients. HCC late-arterial and portal iodine concentrations, blood flow (BF)-related and blood volume (BV)-related perfusion parameters maps were calculated. Mixed-effects models of the relationship between iodine concentrations and perfusion parameters were computed. An adjusted p value (Bonferroni method) < 0.05 was considered significant. RESULTS: Mean HCC late-arterial and portal iodine concentrations were 22.7±12.7 mg/mL and 18.7±8.3 mg/mL, respectively. Late-arterial iodine concentration was significantly related to BV (mixed-effects model F statistic (F)=28.52, p<0.0001), arterial BF (aBF, F=17.62, p<0.0001), hepatic perfusion index (F=28.24, p<0.0001), positive enhancement integral (PEI, F=66.75, p<0.0001) and mean slope of increase (F=32.96, p<0.0001), while portal-venous iodine concentration was mainly related to BV (F=29.68, p<0.0001) and PEI (F=66.75, p<0.0001). CONCLUSIONS: In advanced HCC lesions, DECT-derived late-arterial iodine concentration is strongly related to both aBF and BV, while portal iodine concentration mainly reflects BV, offering DECT the ability to evaluate both morphological and perfusion changes. KEY POINTS: • Late-arterial iodine concentration is highly related to arterial BF and BV. • Portal iodine concentration mainly reflects tumour blood volume. • Dual-energy CT offers significantly decreased radiation dose compared with perfusion CT.


Asunto(s)
Carcinoma Hepatocelular/diagnóstico por imagen , Neoplasias Hepáticas/diagnóstico por imagen , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano , Anciano de 80 o más Años , Carcinoma Hepatocelular/patología , Medios de Contraste/metabolismo , Femenino , Humanos , Yodo/metabolismo , Yopamidol/análogos & derivados , Yopamidol/metabolismo , Hígado/diagnóstico por imagen , Neoplasias Hepáticas/patología , Masculino , Persona de Mediana Edad , Imagen de Perfusión/métodos , Estudios Prospectivos , Intensificación de Imagen Radiográfica/métodos , Reproducibilidad de los Resultados
13.
J Vasc Interv Radiol ; 29(2): 254-261.e2, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-29191614

RESUMEN

PURPOSE: To evaluate accuracy of virtual parenchymal perfusion (VPP) algorithm developed for targeting liver cancer during intra-arterial therapy (IAT) using cone-beam CT guidance. MATERIALS AND METHODS: VPP was retrospectively applied to 15 patients who underwent IAT for liver cancer. Virtual territory (VT) was estimated after positioning a virtual injection point on nonselective dual-phase (DP) cone-beam CT images acquired during hepatic arteriography at the same position chosen for selective treatment. Targeted territory (TT) was used as the gold standard and was defined by parenchymal phase enhancement of selective DP cone-beam CT performed before treatment start. Qualitative evaluation of anatomic conformity between VT and TT was performed using a 3-rank scale (poor, acceptable, excellent) by 3 double-blinded readers. VT and TT were also quantitatively compared using spatial overlap-based (Dice similarity coefficient [DSC], sensitivity, and positive predictive value), distance-based (mean surface distance [MSD]), and volume-based (absolute volume error and correlation between pairwise volumes) metrics. Interreader agreement was evaluated for the 2 evaluation methods. RESULTS: Eighteen DP cone-beam CT scans were performed. Qualitative evaluation showed excellent overlap between VT and TT in 88.9%-94.4%, depending on the readers. DSC was 0.78 ± 0.1, sensitivity was 80%, positive predictive value was 83%, and MSD was 5.1 mm ± 2.4. Absolute volume error was 15%, and R2 Pearson correlation factor was 0.99. Interreader agreement was good for both qualitative and quantitative evaluations. CONCLUSIONS: VPP algorithm is accurate and reliable in identification of liver arterial territories during IAT using cone-beam CT guidance.


Asunto(s)
Algoritmos , Antineoplásicos/administración & dosificación , Quimioembolización Terapéutica/métodos , Tomografía Computarizada de Haz Cónico/métodos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/tratamiento farmacológico , Radiografía Intervencional , Medios de Contraste , Femenino , Humanos , Infusiones Intraarteriales , Masculino , Persona de Mediana Edad , Interpretación de Imagen Radiográfica Asistida por Computador , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad , Resultado del Tratamiento
14.
J Vasc Interv Radiol ; 29(3): 425-431, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29402612

RESUMEN

PURPOSE: To evaluate the performance of automated feeder detection (AFD) software (EmboGuide; Philips Healthcare, Best, The Netherlands) on hepatocellular carcinoma (HCC) tumors during transarterial chemoembolization. MATERIALS AND METHODS: Forty-four first-time transarterial chemoembolization patients (37 men; mean age, 62 ± 11 years) were enrolled between May 2012 and July 2013. A total of 86 HCC lesions were treated (2.0 ± 1.4 lesions per patient; 27.6 ± 15.9 mm maximum diameter). One hundred forty-seven feeding arteries were found with digital subtraction angiography (DSA), cone-beam computed tomography (CT), and AFD software with the option of manual adjustment (MA). Three independent interventional radiologists analyzed the cone-beam CT images retrospectively with and without AFD and MA. Compared with the number of treated vessels, the number of true positives, false positives, false negatives, sensitivity, and interreader agreement were determined using clustered binary data analysis. RESULTS: Cone-beam CT enabled detection of 100 ± 3.5 feeding arteries (70% sensitivity) with 68.6% agreement among readers. AFD software significantly improved detection to 127±0.6 feeding arteries (86% sensitivity, P = .008) with 99.7% reader agreement and reduced the number of false negatives from an average of 47 ± 3.5 to 20 ± 0.6 (P = .008). MA of the AFD results produced similar feeding artery detection rates (127 ± 5.1, 86% sensitivity, P = .8), with lower interreader agreement (91.6%) and slightly fewer false positives (16 ± 0.0 to 14 ± 2.5, P = .4). CONCLUSIONS: AFD software significantly improved feeding artery detection rates during transarterial chemoembolization of HCC lesions with better user reproducibility compared with cone-beam CT alone. In conjunction with DSA, AFD enables maximum feeding artery detection in this setting.


Asunto(s)
Carcinoma Hepatocelular/terapia , Quimioembolización Terapéutica/métodos , Neoplasias Hepáticas/terapia , Radiografía Intervencional/métodos , Programas Informáticos , Angiografía de Substracción Digital , Tomografía Computarizada de Haz Cónico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
15.
J Cardiovasc Magn Reson ; 20(1): 58, 2018 08 16.
Artículo en Inglés | MEDLINE | ID: mdl-30115079

RESUMEN

BACKGROUND: To assess the diagnostic and prognosis value of myocardial native T2 measurement in the distinction between Light-chain (AL) and Transthyretin (ATTR) cardiac amyloidosis (CA). METHODS: Forty-four patients with CA (24 AL; 20 ATTR) and 40 healthy subjects underwent 1.5 T cardiovascular magnetic resonance (CMR). They all underwent T1 and T2 mapping (modified Look-Locker inversion recovery), cine and late gadolinium enhancement (LGE) imaging. The Query Amyloid Late Enhancement (QALE) score, myocardial native T2, T1 and extra cellular volume fraction (ECV) were calculated for all patients. RESULTS: Of the 44 patients, 36 (82%) exhibited enhancement on LGE images. Mean QALE score of AL (7.9 ± 6) and ATTR (10.5 ± 5) patients were similar (p = 0.6). Myocardial native T2 was significantly (p < 0.0001) higher in AL (63.2 ± 4.7 ms) than in ATTR (56.2 ± 3.1 ms) patients, and both higher (p < 0.001) than healthy subjects (51.1 ± 3.1 ms). Myocardial native T2 was highly correlated with myocardial native T1 (Spearman's rho = 0.79; p < 0.001) and exhibited higher diagnostic performance than T1 to separate AL and ATTR patients: the area under curve (AUC) of T2 was 0.94 (95% CI: 0.86-1, p < 0.001) and the AUC of T1 was 0.77 (95% CI: 0.62-0.91, p = 0.03). Myocardial native T2 did not impact overall survival in patients (HR 1.03 (0.94-1.12); p = 0.53) in contrast to ECV that was the best predictor of outcome (HR 1.66 per 0.1 increase in ECV (1.24-2.22); p = 0.0006). CONCLUSIONS: Myocardial native T2 significantly is increased in CA, especially in AL patients in comparison to ATTR patients. Myocardial native T2 does not impact survival in CA patients in contrast to ECV that was the best predictor of outcome. TRIAL REGISTRATION: Trial Registration and unique number: CNIL cardio 1778041. Date of registration: 20 December 2012.


Asunto(s)
Neuropatías Amiloides Familiares/diagnóstico por imagen , Cardiomiopatías/diagnóstico por imagen , Amiloidosis de Cadenas Ligeras de las Inmunoglobulinas/diagnóstico por imagen , Imagen por Resonancia Cinemagnética , Miocardio/patología , Adulto , Anciano , Anciano de 80 o más Años , Neuropatías Amiloides Familiares/patología , Cardiomiopatías/patología , Medios de Contraste/administración & dosificación , Diagnóstico Diferencial , Femenino , Humanos , Amiloidosis de Cadenas Ligeras de las Inmunoglobulinas/patología , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Pronóstico , Reproducibilidad de los Resultados , Estudios Retrospectivos
17.
Radiology ; 279(3): 741-53, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26678453

RESUMEN

Purpose To assess the visibility of radiopaque microspheres during transarterial embolization (TAE) in the VX2 rabbit liver tumor model by using multimodality imaging, including single-snapshot radiography, cone-beam computed tomography (CT), multidetector CT, and micro-CT. Materials and Methods The study was approved by the institutional animal care and use committee. Fifteen VX2-tumor-bearing rabbits were assigned to three groups depending on the type of embolic agent injected: 70-150-µm radiopaque microspheres in saline (radiopaque microsphere group), 70-150-µm radiopaque microspheres in contrast material (radiopaque microsphere plus contrast material group), and 70-150-µm radiolucent microspheres in contrast material (nonradiopaque microsphere plus contrast material group). Rabbits were imaged with single-snapshot radiography, cone-beam CT, and multidetector CT. Three to 5 weeks after sacrifice, excised livers were imaged with micro-CT and histologic analysis was performed. The visibility of the embolic agent was assessed with all modalities before and after embolization by using a qualitative three-point scale score reading study and a quantitative assessment of the signal-to-noise ratio (SNR) change in various regions of interest, including the tumor and its feeding arteries. The Kruskal-Wallis test was used to compare the rabbit characteristics across groups, and the Wilcoxon signed rank test was used to compare SNR measurements before and after embolization. Results Radiopaque microspheres were qualitatively visualized within tumor feeding arteries and targeted tissue with all imaging modalities (P < .05), and their presence was confirmed with histologic examination. SNRs of radiopaque microsphere deposition increased after TAE on multidetector CT, cone-beam CT, and micro-CT images (P < .05). Similar results were obtained when contrast material was added to radiopaque microspheres, except for additional image attenuation due to tumor enhancement. For the group with nonradiopaque microspheres and contrast material, retained tumoral contrast remained qualitatively visible with all modalities except for micro-CT, which demonstrated soluble contrast material washout over time. Conclusion Radiopaque microspheres were visible with all imaging modalities and helped increase conspicuity of the tumor as well as its feeding arteries after TAE in a rabbit VX2 liver tumor model. (©) RSNA, 2015.


Asunto(s)
Embolización Terapéutica , Neoplasias Hepáticas Experimentales/diagnóstico por imagen , Animales , Tomografía Computarizada de Haz Cónico , Medios de Contraste , Aceite Etiodizado , Neoplasias Hepáticas Experimentales/irrigación sanguínea , Masculino , Microesferas , Tomografía Computarizada Multidetector , Imagen Multimodal , Conejos
18.
Radiology ; 278(1): 275-84, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26131913

RESUMEN

PURPOSE: To compare currently available non-three-dimensional methods (Response Evaluation Criteria in Solid Tumors [RECIST], European Association for Study of the Liver [EASL], modified RECIST [mRECIST[) with three-dimensional (3D) quantitative methods of the index tumor as early response markers in predicting patient survival after initial transcatheter arterial chemoembolization (TACE). MATERIALS AND METHODS: This was a retrospective single-institution HIPAA-compliant and institutional review board-approved study. From November 2001 to November 2008, 491 consecutive patients underwent intraarterial therapy for liver cancer with either conventional TACE or TACE with drug-eluting beads. A diagnosis of hepatocellular carcinoma (HCC) was made in 290 of these patients. The response of the index tumor on pre- and post-TACE magnetic resonance images was assessed retrospectively in 78 treatment-naïve patients with HCC (63 male; mean age, 63 years ± 11 [standard deviation]). Each response assessment method (RECIST, mRECIST, EASL, and 3D methods of volumetric RECIST [vRECIST] and quantitative EASL [qEASL]) was used to classify patients as responders or nonresponders by following standard guidelines for the uni- and bidimensional measurements and by using the formula for a sphere for the 3D measurements. The Kaplan-Meier method with the log-rank test was performed for each method to evaluate its ability to help predict survival of responders and nonresponders. Uni- and multivariate Cox proportional hazard ratio models were used to identify covariates that had significant association with survival. RESULTS: The uni- and bidimensional measurements of RECIST (hazard ratio, 0.6; 95% confidence interval [CI]: 0.3, 1.0; P = .09), mRECIST (hazard ratio, 0.6; 95% CI: 0.6, 1.0; P = .05), and EASL (hazard ratio, 1.1; 95% CI: 0.6, 2.2; P = .75) did not show a significant difference in survival between responders and nonresponders, whereas vRECIST (hazard ratio, 0.6; 95% CI: 0.3, 1.0; P = .04), qEASL (Vol) (hazard ratio, 0.5; 95% CI: 0.3, 0.9; P = .02), and qEASL (%) (hazard ratio, 0.3; 95% CI: 0.15, 0.60; P < .001) did show a significant difference between these groups. CONCLUSION: The 3D-based imaging biomarkers qEASL and vRECIST were tumor response criteria that could be used to predict patient survival early after initial TACE and enabled clear identification of nonresponders.


Asunto(s)
Carcinoma Hepatocelular/terapia , Quimioembolización Terapéutica/métodos , Diagnóstico por Imagen , Neoplasias Hepáticas/terapia , Anciano , Carcinoma Hepatocelular/patología , Medios de Contraste/administración & dosificación , Doxorrubicina/administración & dosificación , Femenino , Gadolinio DTPA/administración & dosificación , Humanos , Neoplasias Hepáticas/patología , Masculino , Microesferas , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
19.
J Vasc Interv Radiol ; 27(2): 188-93, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26830935

RESUMEN

Magnetic resonance (MR) angiography image fusion (IF) with live fluoroscopy guidance was used while performing endovascular repair of abdominal aortic aneurysm (EVAR) in five patients with a history of chronic renal disease or severe contrast allergy. Intraprocedural technical success was 100%. Median procedure time was 120 minutes (range, 60-180 min), fluoroscopy time was 40 minutes (range, 17-65 min), dose-area product was 245,867 mGy × cm(2) (range, 68,435-690,053 mGy × cm(2)), and iodinated contrast volume injected was 15 mL (range, 0-40 mL). Technical success was achieved in four of five patients (80%); one case was complicated by a type 1 endoleak on follow-up MR angiography, which was successfully treated. EVAR with MR angiography IF guidance was technically feasible and safe in five patients and reduced or eliminated the use of iodinated contrast media.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Procedimientos Endovasculares/métodos , Imagenología Tridimensional , Angiografía por Resonancia Magnética , Anciano , Anciano de 80 o más Años , Medios de Contraste , Fluoroscopía , Humanos , Masculino , Persona de Mediana Edad , Radiografía Intervencional
20.
Radiology ; 274(2): 320-34, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25625741

RESUMEN

Cone-beam computed tomography (CBCT) is an imaging technique that provides computed tomographic (CT) images from a rotational scan acquired with a C-arm equipped with a flat panel detector. Utilizing CBCT images during interventional procedures bridges the gap between the world of diagnostic imaging (typically three-dimensional imaging but performed separately from the procedure) and that of interventional radiology (typically two-dimensional imaging). CBCT is capable of providing more information than standard two-dimensional angiography in localizing and/or visualizing liver tumors ("seeing" the tumor) and targeting tumors though precise microcatheter placement in close proximity to the tumors ("reaching" the tumor). It can also be useful in evaluating treatment success at the time of procedure ("assessing" treatment success). CBCT technology is rapidly evolving along with the development of various contrast material injection protocols and multiphasic CBCT techniques. The purpose of this article is to provide a review of the principles of CBCT imaging, including purpose and clinical evidence of the different techniques, and to introduce a decision-making algorithm as a guide for the routine utilization of CBCT during transarterial chemoembolization of liver cancer.


Asunto(s)
Quimioembolización Terapéutica/métodos , Tomografía Computarizada de Haz Cónico , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/terapia , Humanos , Guías de Práctica Clínica como Asunto
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA