1.
Magn Reson Med ; 88(3): 1303-1313, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35657055

RESUMEN

PURPOSE: To develop a 2D multi-echo passband balanced SSFP (bSSFP) sequence using an echo-train readout with a sequential phase-encoding order (sequential multi-echo bSSFP), and evaluate its performance in fast functional brain imaging at 7 T. METHODS: As images of sequential multi-echo bSSFP exhibit multiple ghosts due to periodic k-space modulations, a GRAPPA-based reconstruction method was proposed to eliminate ghosting artifacts. MRI experiments were performed to compare the image quality of multi-echo bSSFP and conventional single-echo bSSFP. Submillimeter-resolution fMRI using a checkerboard visual stimulus was conducted to compare the activation characteristics of multi-echo bSSFP, conventional single-echo bSSFP and standard gradient-echo EPI (GE-EPI). RESULTS: A higher mean structural similarity index was found between images of single-echo bSSFP and multi-echo bSSFP with a shorter echo train length (ETL). Multi-echo bSSFP (ETL = 3) showed higher temporal SNR (tSNR) values than GRAPPA-accelerated single-echo bSSFP (R = 2). In submillimeter-resolution fMRI experiments, multi-echo bSSFP (ETL = 3) approached the imaging speed of GRAPPA-accelerated single-echo bSSFP (R = 2), but without tSNR penalty and reduced activation due to acceleration. The median t-value and the number of significantly activated voxels were comparable between GE-EPI and multi-echo bSSFP (ETL = 3) that provides virtually distortion-free functional images and inherits the activation patterns of conventional bSSFP. CONCLUSION: Sequential multi-echo bSSFP (ETL = 3) is suitable for fast fMRI with submillimeter in-plane resolution, and offers an option to accelerate bSSFP imaging without tSNR penalty like parallel imaging.


Asunto(s)
Imagen Eco-Planar , Imagen por Resonancia Magnética , Artefactos , Encéfalo/diagnóstico por imagen , Imagen Eco-Planar/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos
2.
Neuroradiology ; 60(11): 1243-1246, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30244414

RESUMEN

PURPOSE: To evaluate the quality of time-of-flight MR angiography (TOF-MRA) with venous suppression at 7T on imaging superficial temporal artery (STA). METHODS: A recently developed segmented TOF technique with reduced specific absorption rate (SAR) of venous suppression (VS) module was employed to achieve high-resolution arterial angiography without the contamination of venous signal. Images of segmented TOF with VS at 7T, TOF without VS at 7T, and TOF with VS at 3T were collected on 17 healthy volunteers. The number of STA branches and their local contrast achieved by the three methods were quantified and compared using paired t test. RESULTS: Segmented TOF with VS at 7T successfully suppressed venous signal without reducing the contrast of arterial angiography. The numbers of STA branches in 7T images were significantly higher than that in 3T images (5.79 vs. 4.50, p < 0.001). The contrast of 7T segmented TOF was significantly higher than 3T TOF (7.21 vs. 5.56, p = 0.006). CONCLUSION: Segmented TOF with VS at 7T displayed more branches of STA, while eliminating the signal of superficial temporal vein (STV). The improved visualization of STA will potentially facilitate the pre-operative assessment of STA in STA-MCA bypass surgery.


Asunto(s)
Angiografía por Resonancia Magnética/métodos , Arterias Temporales/diagnóstico por imagen , Adolescente , Adulto , Femenino , Voluntarios Sanos , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Masculino
3.
Magn Reson Med ; 65(5): 1314-25, 2011 May.
Artículo en Inglés | MEDLINE | ID: mdl-21305594

RESUMEN

In MRI, the suppression of fat signal is very important for many applications. Multipoint Dixon based water-fat separation methods are commonly used due to its robustness to B(0) homogeneity compared with other fat suppression methods, such as spectral fat saturation. The traditional Cartesian k-space trajectory based multipoint Dixon technique is sensitive to motion, such as pulsatile blood flow, resulting in artifacts that compromise image quality. This work presents a three-point Dixon water-fat separation method using undersampled BLADE (aka PROPELLER) for motion robustness and speed. A regularized iterative reconstruction method is then proposed for reducing the streaking artifacts coming from undersampling. In this study, the performance of the regularized iterative reconstruction method is first tested by simulations and on MR phantoms. The performance of the proposed technique is then evaluated in vivo by comparing it with conventional fat suppression methods on the human brain and knee. Experiments show that the presented method delivers reliable water-fat separation results. The reconstruction method suppresses streaking artifacts typical for undersampled BLADE acquisition schemes without missing fine structures in the image.


Asunto(s)
Aumento de la Imagen/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Tejido Adiposo , Algoritmos , Artefactos , Humanos , Rodilla , Órbita , Fantasmas de Imagen
4.
Front Neurosci ; 15: 620172, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33716650

RESUMEN

The impairment of microvessels can lead to neurologic diseases such as stroke and vascular dementia. The imaging of lumen and vessel wall of perforating arteries requires an extremely high resolution due to their small caliber size. Current imaging techniques have the difficulty in observing the wall of perforating arteries. In this study, we developed a 3D inner-volume (IV) TSE (SPACE) sequence with optimized 2D spatially selective excitation (SSE) RF pulses. The optimized SSE RF pulses were designed through a series of optimization including iterative RF pulse design, trajectory optimization, and phase convention of Carr-Purcell-Meiboom-Gill (CPMG) condition to meet the perforating arteries imaging demands. High resolution of isotropic 0.30 mm within 10 min was achieved for the black- blood images of lenticulostriate artery (LSA). The LSA lumen and vessel wall were imaged by the IV-SPACE sequence simultaneously. Images obtained by the optimized RF pulse has fewer aliasing artifacts from outside of ROI than the traditional pulse. The IV-SPACE images showed clearer delineation of vessel wall and lumen of LSA than conventional SPACE images. IV-SPACE might be a promising method for detecting microvasculopathies of cerebral vascular diseases.

5.
Magn Reson Med ; 62(5): 1251-60, 2009 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-19780176

RESUMEN

The conventional phase difference method for MR thermometry suffers from disturbances caused by the presence of lipid protons, motion-induced error, and field drift. A signal model is presented with multi-echo gradient echo (GRE) sequence using a fat signal as an internal reference to overcome these problems. The internal reference signal model is fit to the water and fat signals by the extended Prony algorithm and the Levenberg-Marquardt algorithm to estimate the chemical shifts between water and fat which contain temperature information. A noise analysis of the signal model was conducted using the Cramer-Rao lower bound to evaluate the noise performance of various algorithms, the effects of imaging parameters, and the influence of the water:fat signal ratio in a sample on the temperature estimate. Comparison of the calculated temperature map and thermocouple temperature measurements shows that the maximum temperature estimation error is 0.614 degrees C, with a standard deviation of 0.06 degrees C, confirming the feasibility of this model-based temperature mapping method. The influence of sample water:fat signal ratio on the accuracy of the temperature estimate is evaluated in a water-fat mixed phantom experiment with an optimal ratio of approximately 0.66:1.


Asunto(s)
Temperatura Corporal/fisiología , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética/métodos , Termografía/métodos , Algoritmos , Simulación por Computador , Humanos , Imagen por Resonancia Magnética/instrumentación , Espectroscopía de Resonancia Magnética/instrumentación , Modelos Biológicos , Fantasmas de Imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
6.
Magn Reson Imaging ; 33(9): 1043-1050, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26220857

RESUMEN

PURPOSE: Time-of-flight (TOF) MR angiography has an advantage of contrast and resolution in ultra-high field (7 T) MRI systems. However, increased specific absorption rate (SAR) prohibits the application of spatial saturation band, leading to venous contamination in maximum intensity projection (MIP) images. METHODS: A segmented k-space filling scheme with sparse venous saturation pulses was developed for 7 T TOF-MRA. The effectiveness of the segmented TOF sequence was verified by Bloch equation simulation and experiments on 3 T. The protocol on 7 T was optimized and applied for healthy volunteers and patients with vascular diseases. RESULTS: Segmented TOF achieved equivalent contrast and venous suppression effect as conventional methods, while SAR values had a remarkable reduction and obeyed the limit of a 7 T MRI system. The decreased number of saturation pulses allowed shorter acquisition time than existing solutions. The comparison of segmented TOF and conventional TOF revealed flow direction in vascular diseases. CONCLUSION: Segmented TOF is proved to be a time-efficient way to achieve high-resolution angiograms without venous contamination at ultra-high field. The sequence holds strong promise for non-contrast clinical diagnosis on cerebrovascular diseases.


Asunto(s)
Trastornos Cerebrovasculares/patología , Medios de Contraste , Aumento de la Imagen , Angiografía por Resonancia Magnética , Adulto , Femenino , Humanos , Masculino , Adulto Joven
7.
Magn Reson Imaging ; 32(2): 175-83, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24268132

RESUMEN

Joint estimation of coil sensitivities and output image (JSENSE) is a promising approach that improves the reconstruction of parallel magnetic resonance imaging (pMRI). However, when acceleration factor increases, the signal to noise ratio (SNR) of JSENSE reconstruction decreases as quickly as that of the conventional pMRI. Although sparse constraints have been used to improve the JSENSE reconstruction in recent years, these constraints only use the sparsity of the output image, which cannot fully exploit the prior information of pMRI. In this paper, we use the sparsity of coil images, instead of the output image, to exploit more prior information for JSENSE. Numerical simulation, phantom and in vivo experiments demonstrate that the proposed method has better performance than the SparseSENSE method and the constrained JSENSE method using the sparsity of the output image only.


Asunto(s)
Encéfalo/fisiología , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Algoritmos , Simulación por Computador , Análisis de Fourier , Humanos , Modelos Teóricos , Fantasmas de Imagen , Programas Informáticos
8.
PLoS One ; 9(3): e93124, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24667489

RESUMEN

OBJECTIVE: Our purpose was to validate an early enhancement time point for accurately measuring the myocardial contrast partition coefficient (lambda) using dynamic-equilibrium magnetic resonance imaging. MATERIALS AND METHODS: The pre- and post-contrast longitudinal relaxation rates (reciprocal of T1) of the interventricular septum (R1(m)) and blood pool (R1(b)) were obtained from fifteen healthy volunteers and three diabetic patients with hypertension using two optimized T1 mapping sequences (modified Look-Locker inversion recovery) on a 3-Tesla magnetic resonance scanner. Reference lambda values were calculated as the slope of the regression line of R1(m) versus R1(b) at dynamic equilibrium (multi-point regression method). The simplified pre-/post-enhancement two-acquisition method (two-point method) was used to calculate lambda by relating the change in R1(m) and R1(b) using different protocols according to the acquisition stage of the post-enhancement data point. The agreement with the referential method was tested by calculating Pearson's correlation coefficient and the intra-class correlation coefficient. RESULTS: The lambda values measured by the two-point method increased (from 0.479 ± 0.041 to 0.534 ± 0.043) over time from 6 to 45 minutes after contrast and exhibited good correlation with the reference at each time point (r ≥ 0.875, p<0.05). The intra-class correlation coefficient on absolute agreement with the reference lambda was 0.946, 0.929 and 0.922 at the 6th, 7th and 8th minutes and dropped from 0.878 to 0.403 from the 9th minute on. CONCLUSIONS: The time-efficient two-point method at 6-8 minutes after the Gd-DTPA bolus injection exhibited good agreement with the multi-point regression method and can be applied for accurate lambda measurement in normal myocardium.


Asunto(s)
Medios de Contraste , Aumento de la Imagen/métodos , Imagen por Resonancia Magnética/métodos , Miocardio , Adulto , Femenino , Gadolinio DTPA , Humanos , Masculino , Persona de Mediana Edad , Fantasmas de Imagen , Análisis de Regresión , Factores de Tiempo , Adulto Joven
9.
Magn Reson Imaging ; 31(5): 656-63, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23290479

RESUMEN

Uniform suppression of fat signal is desired in clinical applications. Based on phase differences introduced by different chemical shift frequencies, Dixon method and its variations are used as alternatives of fat saturation methods, which are sensitive to B0 inhomogeneities. Iterative Decomposition of water and fat with Echo Asymmetry and Least squares estimation (IDEAL) separates water and fat images with flexible echo shifting. Periodically Rotated Overlapping ParallEL Lines with Enhanced Reconstruction (PROPELLER, alternatively termed as BLADE), in conjunction with IDEAL, yields Turboprop IDEAL (TP-IDEAL) and allows for decomposition of water and fat signal with motion correction. However, the flexibility of its parameter setting is limited, and the related phase correction is complicated. To address these problems, a novel method, BLADE-Dixon, is proposed in this study. This method used the same polarity readout gradients (fly-back gradients) to acquire in-phase and opposed-phases images, which led to less complicated phase correction and more flexible parameter setting compared to TP-IDEAL. Parallel imaging and undersampling were integrated to reduce scan time. Phantom, orbit, neck and knee images were acquired with BLADE-Dixon. Water-fat separation results were compared to those measured with conventional turbo spin echo (TSE) Dixon and TSE with fat saturation, respectively, to demonstrate the performance of BLADE-Dixon.


Asunto(s)
Tejido Adiposo/anatomía & histología , Algoritmos , Artefactos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Técnica de Sustracción , Agua/análisis , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
10.
Magn Reson Imaging ; 31(4): 529-37, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23260392

RESUMEN

The partial separability (PS) of spatiotemporal signals has been exploited to accelerate dynamic cardiac MRI by sampling two datasets (training and imaging datasets) without breath-holding or ECG triggering. According to the theory of partially separable functions, the wider the range of spatial frequency components covered by the training dataset, the more accurate the temporal constraint imposed by the PS model. Therefore, it is necessary to develop a new sampling scheme for the PS model in order to cover a wider range of spatial frequency components. In this paper, we propose the use of radial sampling trajectories for collecting the training dataset and Cartesian sampling trajectories for collecting the imaging dataset. In vivo high resolution cardiac MRI experiments demonstrate that the proposed data sampling scheme can significantly improve the image quality. The image quality using the PS model with the proposed sampling scheme is comparable to that of a commercial method using retrospective cardiac gating and breath-holding. The success of this study demonstrates great potential for high-quality, high resolution dynamic cardiac MRI without ECG gating or breath-holding through use of the PS model and the novel data sampling scheme.


Asunto(s)
Algoritmos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Cinemagnética/métodos , Procesamiento de Señales Asistido por Computador , Humanos , Imagen por Resonancia Cinemagnética/instrumentación , Fantasmas de Imagen , Reproducibilidad de los Resultados , Tamaño de la Muestra , Sensibilidad y Especificidad , Análisis Espacio-Temporal
11.
Magn Reson Imaging ; 28(3): 418-26, 2010 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-20133096

RESUMEN

A model-based proton resonance frequency shift (PRFS) thermometry method was developed to significantly reduce the temperature quantification errors encountered in the conventional phase mapping method and the spatiotemporal limitations of the spectroscopic thermometry method. Spectral data acquired using multi-echo gradient echo (GRE) is fit into a two-component signal model containing temperature information and fat is used as the internal reference. The noniterative extended Prony algorithm is used for the signal fitting and frequency estimate. Monte Carlo simulations demonstrate the advantages of the method for optimal water-fat separation and temperature estimation accuracy. Phantom experiments demonstrate that the model-based method effectively reduces the interscan motion effects and frequency disturbances due to the main field drift. The thermometry result of ex vivo goose liver experiment with high intensity focused ultrasound (HIFU) heating was also presented in the paper to indicate the feasibility of the model-based method in real tissue.


Asunto(s)
Tejido Adiposo/fisiología , Algoritmos , Interpretación de Imagen Asistida por Computador/métodos , Hígado/fisiología , Imagen por Resonancia Magnética/métodos , Termografía/métodos , Tejido Adiposo/anatomía & histología , Animales , Temperatura Corporal/fisiología , Gansos , Hígado/anatomía & histología , Valores de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad