1.
J Cardiovasc Electrophysiol ; 35(2): 230-237, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38047467

RESUMEN

INTRODUCTION: The extravascular implantable cardioverter defibrillator (EV ICD) has extended projected battery longevity compared to the subcutaneous implantable cardioverter defibrillator (S-ICD). This study used modeling to characterize the need for generator changes, long-term complications, and overall costs for both the EV ICD and S-ICD in healthcare systems of various countries. METHODS: Battery longevity data were modeled using a Markov model from averages reported in device labeling for the S-ICD and with engineering estimates based on real life usage from EV ICD Pivotal Study patient data to introduce variability. Clinical demographic data were derived from published literature. The primary outcomes were defined as the number of generator replacement surgeries, complications, and total healthcare system costs due to battery depletion over the expected lifetime of patients receiving EV ICD or S-ICD therapy. RESULTS: Average modeled battery longevity was determined to be 7.3 years for the S-ICD versus 11.8 years for the EV ICD. The probability of a complication after a replacement procedure was 1.4%, with an operative mortality rate of 0.02%. The use of EV ICD was associated with 1.4-1.6 fewer replacements on average over an expected patient lifetime as compared to S-ICD and a 24.3%-26.0% reduction in cost. A one-way sensitivity analysis of the model for the US healthcare system found that use of an EV ICD resulted in a reduction in replacement surgeries of greater than 1 (1.1-1.6) along with five-figure cost savings in all scenarios ($18 602-$40 948). CONCLUSION: The longer projected battery life of the EV ICD has the potential to meaningfully reduce long-term morbidity and healthcare resources related to generator changes from the perspective of multiple diverse healthcare systems.


Asunto(s)
Desfibriladores Implantables , Humanos , Falla de Equipo , Cardioversión Eléctrica/efectos adversos , Predicción , Ahorro de Costo
2.
J Cardiovasc Electrophysiol ; 35(5): 1050-1054, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38501328

RESUMEN

INTRODUCTION: Tricuspid regurgitation is associated with significant morbidity and mortality, and occurs at a higher rate in patients with cardiovascular implantable electronic devices. Percutaneous strategies for managing tricuspid regurgitation are evolving, including the development of bicaval valve implantation which has been successfully used in patients with pacing leads. METHODS AND RESULTS: We present the first documented case of lead failure following TricValve® implantation, a dedicated self-expanding system for bicaval valve implantation, and the first successful lead revision procedure in this setting. CONCLUSION: The case illustrates important considerations in undertaking percutaneous intervention in patients with cardiovascular implantable electronic devices, and their ongoing management.


Asunto(s)
Desfibriladores Implantables , Falla de Equipo , Insuficiencia de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/fisiopatología , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Masculino , Anciano , Resultado del Tratamiento , Reoperación , Diseño de Prótesis , Remoción de Dispositivos , Femenino , Cardioversión Eléctrica/instrumentación , Cardioversión Eléctrica/efectos adversos
3.
Catheter Cardiovasc Interv ; 104(1): 23-26, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38764302

RESUMEN

We report two case series in which we encountered the difficulties to retrieve disrupted devices during percutaneous coronary intervention and endovascular treatment. The broken devices were successfully and safely retrieved by the "flower technique" that creates multiple cut and slit in the tip of the guiding catheter. This technique can be easily and safely applied in situations where a balloon catheter or stent has been disrupted and device entrapment has occurred, as the technique simply involves manually placing multiple cuts or slits in the tip of the guiding catheter. Transcatheter interventionists should be familiar with this technique because it can be bailout from device entrapment without additional cost or clinical experience.


Asunto(s)
Angioplastia Coronaria con Balón , Catéteres Cardíacos , Remoción de Dispositivos , Humanos , Masculino , Resultado del Tratamiento , Angioplastia Coronaria con Balón/instrumentación , Stents , Anciano , Falla de Equipo , Persona de Mediana Edad , Femenino , Diseño de Equipo
4.
Catheter Cardiovasc Interv ; 103(6): 1035-1041, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38545668

RESUMEN

A distinctive complication with balloon-expandable (BE) THV platforms such as the Edwards Sapien (Edwards Lifescience) is the possibility of balloon rupture during THV deployment. Balloon rupture is a rare occurrence that can result in stroke due to fragment embolism, incomplete THV expansion, and/or vascular injury upon retrieval of the balloon. Careful evaluation of preoperative computed tomography is essential to identify high-risk cases. While annular and left ventricular outflow tract (LVOT) calcification are widely acknowledged as common risks for balloon injury, it's essential to note that balloon injury can manifest at various anatomical sites. In this review, we discuss the mechanism behind balloon rupture, methods to identify cases at a heightened risk of balloon injury, approaches to mitigate the risk of rupture, and percutaneous retrieval strategies.


Asunto(s)
Valvuloplastia con Balón , Falla de Equipo , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Valvuloplastia con Balón/efectos adversos , Valvuloplastia con Balón/instrumentación , Catéteres Cardíacos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Resultado del Tratamiento
5.
Gastrointest Endosc ; 99(6): 1035-1038, 2024 06.
Artículo en Inglés | MEDLINE | ID: mdl-38316225

RESUMEN

BACKGROUND AND AIMS: The SpyGlass (Boston Scientific, Marlborough, Mass, USA) single-operator cholangioscopy (SOC) system is generally considered to be safe but adds additional risks to those associated with standard ERCP. METHODS: We evaluated adverse events (AEs) associated with the SpyGlass system reported in the U.S. Food and Drug Administration Manufacturer and User Facility Device Experience database between January 2016 and August 2023. RESULTS: From the database, 2311 device problems (SpyGlass DS, 1301; SpyGlass DS II, 1010) were reported. An optical problem was the most reported issue (SpyGlass DS, 83; SpyGlass DS II, 457). Patient-related events were found in 62 of 1743 reports (3.5%): 33 with the SpyGlass DS and 29 with the SpyGlass DS II. The most common AEs were bleeding/hemorrhage followed by perforation; infection, fever, or sepsis; and pancreatitis. CONCLUSIONS: Our findings add to the existing literature and provide a fuller picture of potential problems associated with the SpyGlass SOC.


Asunto(s)
Bases de Datos Factuales , Endoscopía del Sistema Digestivo , Humanos , Endoscopía del Sistema Digestivo/efectos adversos , Endoscopía del Sistema Digestivo/métodos , Endoscopía del Sistema Digestivo/instrumentación , Estados Unidos , Pancreatitis/etiología , Sepsis/etiología , Falla de Equipo , Colangiopancreatografia Retrógrada Endoscópica/efectos adversos , Colangiopancreatografia Retrógrada Endoscópica/métodos , Perforación Intestinal/etiología , United States Food and Drug Administration , Hemorragia/etiología , Hemorragia Gastrointestinal/etiología
6.
Europace ; 26(6)2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38861398

RESUMEN

AIMS: Subcutaneous implantable cardioverter-defibrillators (S-ICDs) offer potentially distinct advantages over transvenous defibrillator systems. Recent randomized trials showed significantly lower lead failure rates than transvenous ICD. Still, S-ICDs remain associated with the risk of inappropriate shocks (IAS). While previous studies have reported varying causes of IAS, this study explores a rare cause of IAS, referred to as 'sense-B-noise.' It was recently described in case series, but its incidence has not been studied in a large cohort of S-ICD patients. METHODS AND RESULTS: We retrospectively reviewed data from patients implanted with S-ICD models 1010, A209, and A219 between October 2009 and July 2023 across nine centres in Europe and the USA. The analysis concentrated on determining the incidence and understanding the implications of sense-B-noise events. Sense-B-noise represents a rare manifestation of distinct electrogram abnormalities within the primary and alternate sensing vectors. Data were collected from medical records, device telemetry, and manufacturer reports for investigation. This registry is registered on clinicaltrials.gov (NCT05713708). Subcutaneous implantable cardioverter-defibrillator devices of the 1158 patients were analysed. The median follow-up time for all patients was 46 (IQR 23-64) months. In 107 patients (9.2%) ≥1 IAS was observed during follow-up. Sense-B-noise failure was diagnosed in six (0.5 and 5.6% of all IAS) patients, in all patients, the diagnosis was made after an IAS episode. Median lead dwell time in the affected patients was 23 (2-70) months. To resolve the sense-B-noise defect, in three patients reprogramming to the secondary vector was undertaken, and two patients underwent system removal with subsequent S-ICD reimplantation due to low amplitude in the secondary vector. In one patient, the secondary vector was initially programmed, and subsequently, an S-ICD system exchange was performed due to T-wave-oversensing IAS episodes. CONCLUSION: This multicentre analysis' findings shed light on a rare but clinically highly significant adverse event in S-ICD therapy. To our knowledge, we provide the first systematic multicentre analysis investigating the incidence of sense-B-noise. Due to being difficult to diagnose and limited options for resolution, management of sense-B-noise is challenging. Complete system exchange may be the only option for some patients. Educating healthcare providers involved in S-ICD patient care is crucial for ensuring accurate diagnosis and effective management of sense-B-noise issues.


Asunto(s)
Desfibriladores Implantables , Cardioversión Eléctrica , Sistema de Registros , Humanos , Masculino , Estudios Retrospectivos , Femenino , Persona de Mediana Edad , Incidencia , Cardioversión Eléctrica/instrumentación , Cardioversión Eléctrica/efectos adversos , Anciano , Europa (Continente)/epidemiología , Falla de Equipo/estadística & datos numéricos , Estados Unidos/epidemiología , Factores de Riesgo
7.
Europace ; 26(7)2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38885309

RESUMEN

AIMS: Subcutaneous implantable cardioverter-defibrillators (S-ICDs) have become established in preventing sudden cardiac death, with some advantages over transvenous defibrillator systems, including a lower incidence of lead failures. Despite technological advancements, S-ICD carriers may suffer from significant complications, such as premature battery depletion (PBD), that led to an advisory for nearly 40 000 patients. This multicentre study evaluated the incidence of PBD in a large set of S-ICD patients. METHODS AND RESULTS: Data from patients implanted with S-ICD models A209 and A219 between October 2012 and July 2023 across nine centres in Europe and the USA were reviewed. Incidence and implications of PBD, defined as clinically observed sudden drop in battery longevity, were analysed and compared to PBD with the definition of battery depletion within 60 months. Prospectively collected clinical data were obtained retrospectively from medical records, device telemetry, and manufacturer reports. This registry is listed on ClinicalTrials.gov (NCT05713708). Of the 1112 S-ICD devices analysed, 547 (49.2%) were equipped with a potentially affected capacitor linked to PBD occurrence, currently under Food and Drug Administration advisory. The median follow-up time for all patients was 46 [inter-quartile range (IQR) 24-63] months. Clinically suspected PBD was observed in 159 (29.1%) of cases, with a median time to generator removal or replacement of 65 (IQR 55-72) months, indicative of significant deviations from expected battery lifespan. Manufacturer confirmation of PBD was made in 91.7% of devices returned for analysis. No cases of PBD were observed in devices that were not under advisory. CONCLUSION: This manufacturer-independent analysis highlights a notable incidence of PBD in patients equipped with S-ICD models under advisory, and the rate of PBD in this study corresponds to the rate currently estimated by the manufacturer. To the best of our knowledge, this provides the largest contemporary peer-reviewed study cohort investigating the actual incidence of PBD in S-ICD patients. These findings emphasize the importance of post-market registries in collaboration between clinicians and the manufacturer to optimize safety and efficacy in S-ICD treatment.


Asunto(s)
Desfibriladores Implantables , Suministros de Energía Eléctrica , Sistema de Registros , Humanos , Masculino , Femenino , Persona de Mediana Edad , Estudios Retrospectivos , Anciano , Estados Unidos/epidemiología , Muerte Súbita Cardíaca/prevención & control , Muerte Súbita Cardíaca/epidemiología , Europa (Continente)/epidemiología , Cardioversión Eléctrica/instrumentación , Cardioversión Eléctrica/efectos adversos , Falla de Equipo/estadística & datos numéricos , Factores de Tiempo , Análisis de Falla de Equipo/estadística & datos numéricos , Adulto
8.
Semin Dial ; 37(3): 273-276, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38432229

RESUMEN

Mechanical problems like break or crack in Luer connectors or hubs, clamps, and tubings are common non-infectious complications of tunneled dialysis catheters (TDC), which may lead to other TDC complications and the need to insert a new catheter. These can be tackled using TDC repair kits or spare parts, which are often not available, resulting in the insertion of a new TDC that increases morbidity, TDC-related procedures, and healthcare costs. We discuss two cases of broken Luer connections of TDC, which were managed by exchanging the broken Luer connector of TDC with the similar Luer connector of a temporary dialysis catheter. Both the repaired TDCs are thereafter functioning well. This improvised technique provides an easy, effective, long-lasting option that salvages the existing TDC and reduces the cost factor.


Asunto(s)
Catéteres de Permanencia , Falla de Equipo , Diálisis Renal , Humanos , Diálisis Renal/economía , Diálisis Renal/instrumentación , Catéteres de Permanencia/efectos adversos , Catéteres de Permanencia/economía , Masculino , Fallo Renal Crónico/terapia , Persona de Mediana Edad , Cateterismo Venoso Central/efectos adversos , Cateterismo Venoso Central/economía , Cateterismo Venoso Central/instrumentación , Análisis Costo-Beneficio , Femenino , Remoción de Dispositivos/métodos , Remoción de Dispositivos/economía , Diseño de Equipo
9.
Pacing Clin Electrophysiol ; 47(7): 977-979, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38641950

RESUMEN

BACKGROUND: Lead dwell time is the single strongest predictor of failure and complications in transvenous lead extraction. OBJECTIVES: To report the success rate and complications of transvenous lead extractions with implant dwell time of at least 15 years. METHODS: Procedural and patient data were prospectively collected into a database. The excimer laser was the primary method for lead extraction with the use of mechanical rotational sheaths and femoral snares at operator discretion. RESULTS: A total of 442 patients between 2011 and 2020 underwent lead extraction (705 leads) primarily for infection or device failure at our high-volume center. Forty-one patients with 71 leads > 15 years old were included in this cohort. Mean patient age was 53.5 ± 18.5 years, 67.5% were male. Mean lead dwell time was 19.6 ± 4.4 years. Thirty-six of 41 (88%) patients had successful extraction of all leads compared to 96% in the remaining 401 patients, p value.004. Of the five patients without fully successful extractions two of these patients had abandoned leads (three total) that were clinically significant. There were two (4.9%) major complications in the very old lead group and six (1.5%) in the other group. In the very old lead group, one patient experienced right atrial appendage perforation requiring surgical repair and recovered well. One patient experienced new complete heart block requiring 2 min of CPR but did well thereafter. There was no procedure-related mortality. CONCLUSIONS: Despite challenges posed by older leads, very old leads can be safely and effectively extracted with low complication rates.


Asunto(s)
Remoción de Dispositivos , Marcapaso Artificial , Humanos , Masculino , Femenino , Remoción de Dispositivos/métodos , Persona de Mediana Edad , Desfibriladores Implantables , Factores de Tiempo , Falla de Equipo , Estudios Prospectivos
10.
Pacing Clin Electrophysiol ; 47(7): 878-884, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38661716

RESUMEN

INTRODUCTION: Catheter ablation (CA) can interfere with cardiac implantable electronic device (CIED) function. The safety of CA in the 1st year after CIED implantation/lead revision is uncertain. METHODS: This single center, retrospective cohort included patients who underwent CA between 2012 and 2017 and had a CIED implant/lead revision within the preceding year. We assessed the frequency of device/lead malfunctions in this population. RESULTS: We identified 1810 CAs in patients between 2012 and 2017, with 170 CAs in 163 patients within a year of a CIED implant/lead revision. Mean age 68 ± 12 years (68% men). Time between the CIED procedure and CA was 158 ± 99 days. The CA procedures included AF ablation (n = 57, 34%), AV node ablation (n = 40, 24%), SVT ablation (n = 37, 22%), and PVC/VT ablations (n = 36, 21%). The cumulative frequency of lead dislodgement, significant CIED dysfunction, and/or CIED-related infection following CA was (n = 1/170, 0.6%). There was a single atrial lead dislodgement (0.6%). There were no instances of power-on-reset or CIED-related infection. Following CA, there was no significant difference in RA or RV lead sensing (p = 0.52 and 0.84 respectively) or thresholds (p = 0.94 and 0.17 respectively). The RA impedance slightly decreased post-CA from 474 ± 80 Ohms to 460 ± 73 Ohms (p = 0.002), as did the RV impedance (from 515 ± 111 Ohms to 497 ± 98 Ohms, p < 0.0001). CONCLUSIONS: CA can be performed within 1 year following CIED implantation/lead revision with a low risk of CIED/lead malfunction or lead dislodgement. The ideal time to perform CA after a CIED remains uncertain.


Asunto(s)
Ablación por Catéter , Desfibriladores Implantables , Marcapaso Artificial , Humanos , Masculino , Femenino , Estudios Retrospectivos , Anciano , Ablación por Catéter/instrumentación , Falla de Equipo
11.
Dig Dis Sci ; 69(6): 2018-2025, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38580887

RESUMEN

INTRODUCTION: Pancreatic duct stents (PDS) are widely used for the prevention of post-endoscopic retrograde cholangiopancreatography (ERCP) pancreatitis. However, there is a paucity of data regarding the adverse events associated with PDS placement. This study aims to investigate the reported adverse events and device failures related to PDS, utilizing the Manufacturer and User Facility Device Experience (MAUDE) database maintained by the U.S. Food and Drug Administration (FDA). METHODS: Post-marketing surveillance data from January 2013 to December 8, 2023, were extracted from the FDA's MAUDE database to analyze the reports pertaining to the use of commonly used PDS. The primary outcomes of interest were device issues and patient-related adverse events. Statistical analysis was performed using Microsoft Excel 2010, with the calculation of pooled numbers and percentages for each device and patient adverse event. RESULTS: A total of 579 device issues and 194 patient-related adverse events were identified. Device issues were primarily attributed to stent deformation (n = 72; 12.4%), followed by migration of the device into the pancreatic duct or expulsion out of the duct (n = 60; 10.4%), and stent fracture/breakage (n = 55; 9.4%). Among the patient-reported adverse events, inflammation was the most common (n = 26; 13.4%), followed by reports of stents becoming embedded in tissue (n = 21; 10.8%) and stent occlusion/obstruction (n = 16; 8.2%). The most prevalent device failures associated with Advanix stents were material deformation, with perforation (n = 3, 30%) being the most frequently reported adverse event. Concerning Geenen stents, migration or expulsion of the device (n = 34, 16.9%) constituted the most common device-related adverse events, while inflammation (n = 20, 16.7%) was the most frequently reported patient-related issue. For Zimmon stents, migration or expulsion of the device (n = 22, 8.8%) were the most frequently reported device-related problems, whereas perforation (n = 7, 10.9%) and bleeding (n = 7, 10.9%) were the most frequent patient-related adverse events. CONCLUSION: Our findings highlight important device and patient adverse events that endoscopists and referring providers should be aware of before considering pancreatic stent placement.


Asunto(s)
Bases de Datos Factuales , Conductos Pancreáticos , Vigilancia de Productos Comercializados , Falla de Prótesis , Stents , United States Food and Drug Administration , Humanos , Estados Unidos/epidemiología , Stents/efectos adversos , Conductos Pancreáticos/cirugía , Colangiopancreatografia Retrógrada Endoscópica/efectos adversos , Colangiopancreatografia Retrógrada Endoscópica/instrumentación , Pancreatitis/etiología , Pancreatitis/epidemiología , Pancreatitis/prevención & control , Falla de Equipo/estadística & datos numéricos , Migración de Cuerpo Extraño/etiología , Migración de Cuerpo Extraño/epidemiología , Migración de Cuerpo Extraño/prevención & control
12.
Cochrane Database Syst Rev ; 5: CD013023, 2024 05 23.
Artículo en Inglés | MEDLINE | ID: mdl-38780138

RESUMEN

BACKGROUND: Peripheral arterial catheters (ACs) are used in anaesthesia and intensive care settings for blood sampling and monitoring. Despite their importance, ACs often fail, requiring reinsertion. Dressings and securement devices maintain AC function and prevent complications such as infection. OBJECTIVES: To evaluate the effectiveness of peripheral AC dressing and securement devices to prevent failure and complications in hospitalised people. SEARCH METHODS: We searched the Cochrane Wounds Specialised Register, CENTRAL, MEDLINE, Embase, and CINAHL Plus up to 16 May 2023. We also searched ClinicalTrials.gov and the World Health Organization International Clinical Trials Registry Platform up to 16 May 2023. SELECTION CRITERIA: We included randomised controlled trials (RCTs) comparing different dressing and securement devices for the stabilisation of ACs in hospitalised people. DATA COLLECTION AND ANALYSIS: Two review authors independently selected trials for inclusion, extracted data, and assessed risk of bias using Cochrane's RoB 1 tool. We resolved disagreements by discussion, or by consulting a third review author when necessary. We assessed the certainty of evidence using GRADE. MAIN RESULTS: We included five RCTs with 1228 participants and 1228 ACs. All included studies had high risk of bias in one or more domains. We present the following four comparisons, with the remaining comparisons reported in the main review. Standard polyurethane (SPU) plus tissue adhesive (TA) compared with SPU: we are very uncertain whether use of SPU plus TA impacts rates of AC failure (risk ratio (RR) 0.44, 95% confidence interval (CI) 0.20 to 0.98; I² = 0%; 2 studies, 165 participants; very low-certainty evidence). Neither study (165 participants) reported catheter-related bloodstream infections (CRBSI), thus we are very uncertain whether SPU plus TA impacts on the incidence of CRBSI (very low-certainty evidence). It is very uncertain whether use of SPU plus TA impacts AC dislodgement risk (RR 0.54, 95% CI 0.03 to 9.62; I² = 44%; 2 studies, 165 participants; very low-certainty evidence). We are very uncertain whether use of SPU plus TA impacts AC occlusion rates (RR 1.20, 95% CI 0.37 to 3.91; I² = 3%; 2 studies, 165 participants; very low-certainty evidence). We are very uncertain whether use of SPU plus TA impacts rates of adverse events with few reported events across groups (RR 0.89, 95% CI 0.09 to 8.33; I² = 0%; 2 studies, 165 participants; very low-certainty evidence). Bordered polyurethane (BPU) compared to SPU: we are very uncertain whether use of BPU impacts rates of AC failure (RR 0.67, 95% CI 0.21 to 2.13; 1 study, 60 participants; very low-certainty evidence). BPU may make little or no difference to CRBSI compared to SPU (RR 3.05, 95% CI 0.12 to 74.45; I² = not applicable as 1 study (60 participants) reported 0 events; 2 studies, 572 participants; low-certainty evidence). BPU may make little or no difference to the risk of AC dislodgement compared with SPU (RR 0.75, 95% CI 0.17 to 3.22; I² = 0%; 2 studies, 572 participants; low-certainty evidence). BPU may make little or no difference to occlusion risk compared with SPU (RR 0.80, 95% CI 0.60 to 1.07; I² = 0%; 2 studies, 572 participants; low-certainty evidence). It is very uncertain whether BPU impacts on the risk of adverse events compared with SPU (RR 0.33, 95% CI 0.01 to 7.87; 1 study, 60 participants; very low-certainty evidence). SPU plus sutureless securement devices (SSD) compared to SPU: we are very uncertain whether SPU plus SSD impacts risk of AC failure compared with SPU (RR 0.78, 95% CI 0.40 to 1.52; I² = 0%; 2 studies, 157 participants; very low-certainty evidence). We are very uncertain if SPU plus SSD impacts CRBSI incidence rate with no events in both groups (2 studies, 157 participants; very low-certainty evidence). It is very uncertain whether SPU plus SSD impacts risk of dislodgement (RR 0.14, 95% CI 0.01 to 2.57; I² = not applicable as 1 study (96 participants) reported 0 events; 2 studies, 157 participants; very low-certainty evidence). It is very uncertain whether SPU plus SSD impacts risk of AC occlusion (RR 1.94, 95% CI 0.50 to 7.48; I² = 38%; 2 studies, 157 participants; very low-certainty evidence). We are very uncertain whether SPU plus SSD impacts on the risk of adverse events (RR 1.94, 95% CI 0.19 to 20.24; I² = not applicable as 1 study (96 participants) reported 0 events; 2 studies, 157 participants; very low-certainty evidence). Integrated securement dressings compared to SPU: integrated securement dressings may result in little or no difference in risk of AC failure compared with SPU (RR 1.96, 95% CI 0.80 to 4.84; 1 study, 105 participants; low-certainty evidence); may result in little or no difference in CRBSI incidence with no events reported (1 study, 105 participants; low-certainty evidence); may result in little or no difference in the risk of dislodgement (RR 0.33, 95% CI 0.04 to 3.04; 1 study, 105 participants; low-certainty evidence), may result in little or no difference in occlusion rates with no events reported (1 study, 105 participants; low-certainty evidence), and may result in little or no difference in the risk of adverse events (RR 0.35, 95% CI 0.01 to 8.45; 1 study, 105 participants; low-certainty evidence). AUTHORS' CONCLUSIONS: There is currently limited rigorous RCT evidence available about the relative clinical effectiveness of AC dressing and securement products. Limitations of current evidence include small sample size, infrequent events, and heterogeneous outcome measurements. We found no clear difference in the incidence of AC failure, CRBSI, or adverse events across AC dressing or securement products including SPU, BPU, SSD, TA, and integrated securement products. The limitations of current evidence means further rigorous RCTs are needed to reduce uncertainty around the use of dressing and securement devices for ACs.


Asunto(s)
Vendajes , Infecciones Relacionadas con Catéteres , Cateterismo Periférico , Poliuretanos , Ensayos Clínicos Controlados Aleatorios como Asunto , Humanos , Cateterismo Periférico/efectos adversos , Cateterismo Periférico/instrumentación , Infecciones Relacionadas con Catéteres/prevención & control , Sesgo , Falla de Equipo
13.
Cochrane Database Syst Rev ; 6: CD013366, 2024 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-38940297

RESUMEN

BACKGROUND: Peripherally inserted central catheters (PICCs) facilitate diagnostic and therapeutic interventions in health care. PICCs can fail due to infective and non-infective complications, which PICC materials and design may contribute to, leading to negative sequelae for patients and healthcare systems. OBJECTIVES: To assess the effectiveness of PICC material and design in reducing catheter failure and complications. SEARCH METHODS: The University of Queensland and Cochrane Vascular Information Specialist searched the Cochrane Vascular Specialised Register, CENTRAL, MEDLINE, Embase, and CINAHL databases and the WHO ICTRP and ClinicalTrials.gov trials registers to 16 May 2023. We aimed to identify other potentially eligible trials or ancillary publications by searching the reference lists of retrieved included trials, as well as relevant systematic reviews, meta-analyses, and health technology assessment reports. We contacted experts in the field to ascertain additional relevant information. SELECTION CRITERIA: We included randomised controlled trials (RCTs) evaluating PICC design and materials. DATA COLLECTION AND ANALYSIS: We used standard Cochrane methods. Our primary outcomes were venous thromboembolism (VTE), PICC-associated bloodstream infection (BSI), occlusion, and all-cause mortality. Secondary outcomes were catheter failure, PICC-related BSI, catheter breakage, PICC dwell time, and safety endpoints. We assessed the certainty of evidence using GRADE. MAIN RESULTS: We included 12 RCTs involving approximately 2913 participants (one multi-arm study). All studies except one had a high risk of bias in one or more risk of bias domain. Integrated valve technology compared to no valve technology for peripherally inserted central catheter design Integrated valve technology may make little or no difference to VTE risk when compared with PICCs with no valve (risk ratio (RR) 0.71, 95% confidence interval (CI) 0.19 to 2.63; I² = 0%; 3 studies; 437 participants; low certainty evidence). We are uncertain whether integrated valve technology reduces PICC-associated BSI risk, as the certainty of the evidence is very low (RR 0.20, 95% CI 0.01 to 4.00; I² = not applicable; 2 studies (no events in 1 study); 257 participants). Integrated valve technology may make little or no difference to occlusion risk when compared with PICCs with no valve (RR 0.86, 95% CI 0.53 to 1.38; I² = 0%; 5 studies; 900 participants; low certainty evidence). We are uncertain whether use of integrated valve technology reduces all-cause mortality risk, as the certainty of evidence is very low (RR 0.85, 95% CI 0.44 to 1.64; I² = 0%; 2 studies; 473 participants). Integrated valve technology may make little or no difference to catheter failure risk when compared with PICCs with no valve (RR 0.80, 95% CI 0.62 to 1.03; I² = 0%; 4 studies; 720 participants; low certainty evidence). We are uncertain whether integrated-valve technology reduces PICC-related BSI risk (RR 0.51, 95% CI 0.19 to 1.32; I² = not applicable; 2 studies (no events in 1 study); 542 participants) or catheter breakage, as the certainty of evidence is very low (RR 1.05, 95% CI 0.22 to 5.06; I² = 20%; 4 studies; 799 participants). Anti-thrombogenic surface modification compared to no anti-thrombogenic surface modification for peripherally inserted central catheter design We are uncertain whether use of anti-thrombogenic surface modified catheters reduces risk of VTE (RR 0.67, 95% CI 0.13 to 3.54; I² = 15%; 2 studies; 257 participants) or PICC-associated BSI, as the certainty of evidence is very low (RR 0.20, 95% CI 0.01 to 4.00; I² = not applicable; 2 studies (no events in 1 study); 257 participants). We are uncertain whether use of anti-thrombogenic surface modified catheters reduces occlusion (RR 0.69, 95% CI 0.04 to 11.22; I² = 70%; 2 studies; 257 participants) or all-cause mortality risk, as the certainty of evidence is very low (RR 0.49, 95% CI 0.05 to 5.26; I² = not applicable; 1 study; 111 participants). Use of anti-thrombogenic surface modified catheters may make little or no difference to risk of catheter failure (RR 0.76, 95% CI 0.37 to 1.54; I² = 46%; 2 studies; 257 participants; low certainty evidence). No PICC-related BSIs were reported in one study (111 participants). As such, we are uncertain whether use of anti-thrombogenic surface modified catheters reduces PICC-related BSI risk (RR not estimable; I² = not applicable; very low certainty evidence). We are uncertain whether use of anti-thrombogenic surface modified catheters reduces the risk of catheter breakage, as the certainty of evidence is very low (RR 0.15, 95% CI 0.01 to 2.79; I² = not applicable; 2 studies (no events in 1 study); 257 participants). Antimicrobial impregnation compared to non-antimicrobial impregnation for peripherally inserted central catheter design We are uncertain whether use of antimicrobial-impregnated catheters reduces VTE risk (RR 0.54, 95% CI 0.05 to 5.88; I² = not applicable; 1 study; 167 participants) or PICC-associated BSI risk, as the certainty of evidence is very low (RR 2.17, 95% CI 0.20 to 23.53; I² = not applicable; 1 study; 167 participants). Antimicrobial-impregnated catheters probably make little or no difference to occlusion risk (RR 1.00, 95% CI 0.57 to 1.74; I² = 0%; 2 studies; 1025 participants; moderate certainty evidence) or all-cause mortality (RR 1.12, 95% CI 0.71 to 1.75; I² = 0%; 2 studies; 1082 participants; moderate certainty evidence). Antimicrobial-impregnated catheters may make little or no difference to risk of catheter failure (RR 1.04, 95% CI 0.82 to 1.30; I² = not applicable; 1 study; 221 participants; low certainty evidence). Antimicrobial-impregnated catheters probably make little or no difference to PICC-related BSI risk (RR 1.05, 95% CI 0.71 to 1.55; I² = not applicable; 2 studies (no events in 1 study); 1082 participants; moderate certainty evidence). Antimicrobial-impregnated catheters may make little or no difference to risk of catheter breakage (RR 0.86, 95% CI 0.19 to 3.83; I² = not applicable; 1 study; 804 participants; low certainty evidence). AUTHORS' CONCLUSIONS: There is limited high-quality RCT evidence available to inform clinician decision-making for PICC materials and design. Limitations of the current evidence include small sample sizes, infrequent events, and risk of bias. There may be little to no difference in the risk of VTE, PICC-associated BSI, occlusion, or mortality across PICC materials and designs. Further rigorous RCTs are needed to reduce uncertainty.


Asunto(s)
Infecciones Relacionadas con Catéteres , Cateterismo Periférico , Diseño de Equipo , Falla de Equipo , Ensayos Clínicos Controlados Aleatorios como Asunto , Tromboembolia Venosa , Humanos , Cateterismo Periférico/efectos adversos , Cateterismo Periférico/instrumentación , Infecciones Relacionadas con Catéteres/prevención & control , Tromboembolia Venosa/prevención & control , Tromboembolia Venosa/etiología , Obstrucción del Catéter , Catéteres Venosos Centrales/efectos adversos , Causas de Muerte , Sesgo , Cateterismo Venoso Central/efectos adversos , Cateterismo Venoso Central/instrumentación , Bacteriemia/prevención & control , Bacteriemia/etiología
14.
Neurol Sci ; 45(7): 3495-3501, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38714597

RESUMEN

BACKGROUND: Shunt obstruction is a type of ventriculoperitoneal shunt (VPS) failure. Whether changes in cerebrospinal fluid (CSF) parameters can influence shunt outcomes or not is debatable. METHODS: In this study, we retrospectively included adult hydrocephalus patients who received VPS from 6 general hospitals in different provinces of China from November 2013 to September 2021. The inclusion criteria: Patients with hydrocephalus of all etiologies underwent shunt surgery from 6 general hospitals in different provinces of China were included in the study. The exclusion criteria: 1.Patients under the age of 18; 2.Patients who had previous shunt surgery; 3. Shunt failure from other factors; 4.Patients died from other causes; 5. Patients with incomplete data. The CSF of shunt patients had been analyzed at the time of shunt insertion. The CSF samples were collected and analyzed when the shunt was implanted. The relationship between CSF parameters and the incidence rate of shunt obstruction in one year was analyzed. RESULTS: A total of 717 eligible patients from 6 hospitals were included, of whom 59(8.23%) experienced obstruction. Multivariate logistic regression analysis identified that protein level(odds ratio [OR] 1.161, 95% CI 1.005 ~ 1.341, p = 0.043), decreased glucose level(< 2.5 mmol/L)(odds ratio 3.784, 95% confidence interval 1.872 ~ 7.652, p = 0.001) and protein level increase(> 0.45 g/L) (odds ratio 3.653, 95% confidence interval 1.931 ~ 6.910, p = 0.001)were independent risk factors of shunt obstruction. CONCLUSION: This study suggested that increased protein level (> 0.45 g/L) and decreased glucose level (< 2.5 mmol/L) in CSF indicated an increased risk of shunt obstruction in a patient with hydrocephalus. Thus, shunt surgery should be more carefully considered when the CSF glucose and protein were abnormal.


Asunto(s)
Hidrocefalia , Derivación Ventriculoperitoneal , Humanos , Derivación Ventriculoperitoneal/efectos adversos , Femenino , Masculino , Hidrocefalia/cirugía , Hidrocefalia/líquido cefalorraquídeo , Estudios Retrospectivos , Persona de Mediana Edad , Anciano , China/epidemiología , Adulto , Falla de Equipo
15.
BMC Pediatr ; 24(1): 441, 2024 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-38987700

RESUMEN

Peripheral intravenous central catheter (PICC) is a common tool for intravenous infusion for children who need central venous access. Although it is safe for physicians and nurses to place, complications like infection, occlusion, phlebitis, and bleeding can occur. We report a 5-month-old infant who suffered respiratory failure caused by catheter malposition resulting in massive fluid infusion into the thoracic cavity. Point-of-care ultrasound (POCUS) was utilized to identify a massive pleural effusion that prompted urgent drainage. Complications related to PICC in pediatric patients are not common but difficult to immediately identify sometimes. Therefore, careful attention should be paid by physicians to identify and reduce the risk of complications associated with PICC. Thus, visual tools are strongly advised to enhance the safety of invasive procedures.


Asunto(s)
Cateterismo Periférico , Derrame Pleural , Atelectasia Pulmonar , Insuficiencia Respiratoria , Humanos , Lactante , Derrame Pleural/etiología , Derrame Pleural/diagnóstico por imagen , Insuficiencia Respiratoria/etiología , Insuficiencia Respiratoria/terapia , Atelectasia Pulmonar/etiología , Atelectasia Pulmonar/diagnóstico por imagen , Cateterismo Periférico/efectos adversos , Masculino , Falla de Equipo , Enfermedad Aguda , Sistemas de Atención de Punto , Ultrasonografía
16.
Regul Toxicol Pharmacol ; 149: 105591, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38467236

RESUMEN

Post-market medical device-associated failures and patient problems are reported in Medical Device Reports (MDRs) to the US Food and Drug Administration. Reports are accessible through Manufacturer and User Facility Device Experience (MAUDE), a database including both required and voluntary submissions. We present an overview of >10 million MDRs received from 2011 to 2021. Approximately 92% of reporting issues represent medical device physical or functional failures, categorized from 1704 codes related to medical device integrity or function. ∼8% were coded adverse events (AEs). Patient outcomes are reported via 998 patient codes in 19 medical specialties (cardiovascular, orthopedic, etc.). ∼40% of patient reports indicated "no health consequences"; however, a small number of devices had consistently high AE reports. While overall reports did not exhibit a sex-based dichotomy, ∼9% of the reported AEs occurred more frequently in females, many of which were related to immune effects. The analyses are subject to uncertainties and potential bias based on data available and data selected for analysis. However, such an overview of post-market MDR data, not previously published, fills a gap in understanding medical device issues and patient-based outcomes related to medical device use. Trends identified may be subjects of additional hypotheses, analysis, and research.


Asunto(s)
Equipos y Suministros , Vigilancia de Productos Comercializados , United States Food and Drug Administration , Humanos , Femenino , Estados Unidos , Equipos y Suministros/efectos adversos , Masculino , Bases de Datos Factuales , Factores Sexuales , Falla de Equipo
17.
Acta Paediatr ; 113(8): 1791-1795, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38760904

RESUMEN

AIM: We wanted to investigate whether an electric rocking device (Swing2Sleep, Neumünster, Germany), sold with the claim to promote infant sleep, would increase total sleep time or reduce sleep latency once infants are put therein. METHODS: In a randomised crossover design, 20 infants (median gestational age at birth 31.7 weeks, range 25-39) were placed to sleep either first with the device rocking, then not rocking (or vice versa) for 5-7 h each. The device consisted of a hammock with three spiral springs that performed vertical swings at a rate of 100/min and an amplitude of 2.5 cm. RESULTS: There was no significant difference in %time spent asleep (83 (22-97) vs. 85% (49-96)), sleep latency (7.7 (2-45) vs. 12.3 (4-42) min), sleep fragmentation (1.3 (0.5-2.3) vs. 1.1 (0.2-5.5)) or efficiency (0.8 (0.2-1.0) vs. 0.9 (0.5-1.0)) between both conditions. CONCLUSION: At its recommended settings, the device did not achieve its intended effect in these infants.


Asunto(s)
Estudios Cruzados , Sueño , Humanos , Recién Nacido , Femenino , Masculino , Falla de Equipo
18.
Neurosurg Rev ; 47(1): 269, 2024 Jun 12.
Artículo en Inglés | MEDLINE | ID: mdl-38864925

RESUMEN

Ventriculoperitoneal shunt surgery was developed to manage excessive cerebrospinal fluid (CSF) in the brain's ventricles and is considered a mainstream treatment. Despite the development of the shunt device system, various complications still occur. In this study, we reported 307 cases and a long-term follow-up of at least five years of adult patients who underwent VP shunt surgery and analyzed various factors that may affect revision surgery. A retrospective study was conducted at Asan Medical Center, Korea, a tertiary medical center. We reviewed 307 cases from January 2012 to December 2018. The patients' neurological status, predisposing medical conditions, laboratory findings, and other operation-related factors were reviewed using electrical medical records. The normal function group comprised 272 cases (88.6%), and the overall incidence of revision group comprised 35 cases (11.4%). Of the 35 revision surgery cases, 30 (85.71%) were due to shunt malfunctions, such as obstruction, overdrainage, and valve-related errors while 5 (14.29%) were due to shunt infection. Patient demographics, mental status, and operation time did not influence revision as risk factors. Serum laboratory findings showed no statistical difference between the two groups. The white blood cell (WBC) count in the CSF profile differed significantly between the two groups. The Hakim Programmable valve (Codman, USA) is mainly used in our center. In addition, various shunt systems were used, including Strata Regulatory valve (Medtronic, USA), proGAV (Aesculap, USA), and Accu-Flo (Codman, USA). This study analyzed the factors affecting long-term outcomes. Based on these findings, efforts are needed to achieve more favorable outcomes in the future.


Asunto(s)
Hidrocefalia , Derivación Ventriculoperitoneal , Humanos , Derivación Ventriculoperitoneal/efectos adversos , Masculino , Femenino , Persona de Mediana Edad , Factores de Riesgo , Adulto , Estudios Retrospectivos , Incidencia , Anciano , Estudios de Seguimiento , Hidrocefalia/cirugía , Reoperación , Complicaciones Posoperatorias/epidemiología , Falla de Equipo , Adulto Joven
19.
Neurosurg Focus ; 56(6): E12, 2024 06.
Artículo en Inglés | MEDLINE | ID: mdl-38823042

RESUMEN

OBJECTIVE: The aim of this study was 1) to describe the rate of intrathecal baclofen (ITB)-associated complications at a large tertiary center, and 2) to evaluate the impact of patient-related factors on the likelihood of developing such complications. METHODS: A retrospective single-center study was carried out. A total of 301 eligible patients were included in the analysis. Univariate regression models were used to evaluate the impact of age, sex, diagnosis, ambulation status, modified Ashworth scale score, body mass index, diabetes status, and pain level on the likelihood of developing a device-related infection, pump malfunction, catheter malfunction, and other clinically significant complications. RESULTS: Overall, 27% of patients experienced an ITB-related complication. The most common complications included infection (6%, 18/301), pump malfunction (7.3%, 22/301), and catheter malfunction (14%, 42/301). The univariate analyses revealed that the patient's ambulatory status had a significant impact on the likelihood of developing a catheter-related malfunction. Furthermore, a trend toward significance was identified between patients' preoperative body mass index and device-related infection. Finally, the risk of suffering any ITB-related complications was statistically correlated with the number of years that had passed since the initial pump implantation. CONCLUSIONS: The authors' analysis reveals a previously underrecognized association between ambulatory status at the time of ITB pump implantation and the incidence of catheter-related complications, and confirms the impact of time since surgery on the risk of developing any ITB-related complication. The patient's age, sex, diagnosis, diabetes status, or pain level at baseline were not associated with the risk of complications. Collectively, these insights contribute novel information to the existing literature, providing practical value for physicians in guiding patient selection for ITB therapy.


Asunto(s)
Baclofeno , Bombas de Infusión Implantables , Inyecciones Espinales , Relajantes Musculares Centrales , Humanos , Baclofeno/administración & dosificación , Baclofeno/efectos adversos , Masculino , Femenino , Persona de Mediana Edad , Estudios Retrospectivos , Adulto , Factores de Riesgo , Bombas de Infusión Implantables/efectos adversos , Relajantes Musculares Centrales/administración & dosificación , Relajantes Musculares Centrales/efectos adversos , Inyecciones Espinales/efectos adversos , Anciano , Adulto Joven , Espasticidad Muscular/tratamiento farmacológico , Falla de Equipo/estadística & datos numéricos , Adolescente
20.
Neurosurg Focus ; 56(6): E11, 2024 06.
Artículo en Inglés | MEDLINE | ID: mdl-38823047

RESUMEN

OBJECTIVE: Intrathecal baclofen (ITB) pumps are commonly used in pediatric patients with cerebral palsy (CP) and medically refractory spasticity. However, catheter malfunction and associated risk factors are not well understood. The aim of this study was to examine potential risk factors for spinal catheter malfunction and characterize postoperative follow-up to understand the clinical consequences. METHODS: Patients who received ITB pump replacement or revision at Boston Children's Hospital between 2010 and 2023 were retrospectively reviewed. The spinal catheter revision cohort (SCRC) included patients whose spinal catheter was occluded requiring lumbar catheter revision. The second cohort included abdominal pump replacements only (APRC). Between-group comparisons and multivariable regression identified factors associated with catheter revision and postoperative outcomes. RESULTS: Forty-one (33.6%) patients underwent spinal catheter revision and were compared with 81 patients (66.4%) who underwent abdominal pump replacement only. Younger age at surgery and an elevated preoperative lower-extremity modified Ashworth scale grade were associated with spinal catheter revision (p < 0.05). Catheter model type, tip location, and history of spinal fusion were not associated with obstruction. Postoperatively, SCRC patients experienced a higher rate of infection (17.1%) relative to APRC patients (0%) within 30 days from their ITB pump replacement procedure (p < 0.05) and greater likelihood of subsequent ITB system removal compared with the APRC (24.4% vs 7.4%, p < 0.05). Although not differing preoperatively, SCRC patients had lower postoperative ITB doses when compared with the APRC group (median dose 143 vs 350 µg/day, p < 0.05) at hospital discharge and remained statistically different at the 6-month and 1-year follow-ups (p < 0.05). There were no postoperative differences in baclofen overdose, withdrawal, or median number of hospital readmissions within 30 days. Overall, 31.7% of spinal catheter revisions were unanticipated by the clinical team at time of surgery. CONCLUSIONS: Younger age at surgery and increased preoperative lower-extremity tone may be risk factors for catheter obstruction, resulting in a higher rate of postoperative infection and subsequent ITB pump removal compared with pump replacement alone. Spinal catheter occlusion can complicate revision or replacement procedures, especially when unanticipated. Routine clinical assessment may be inadequate for diagnosing insidious catheter malfunction. Catheter occlusion deserves further study, and routine assessment of catheter patency may be warranted to prevent suboptimal tone therapy.


Asunto(s)
Baclofeno , Parálisis Cerebral , Bombas de Infusión Implantables , Relajantes Musculares Centrales , Humanos , Baclofeno/administración & dosificación , Baclofeno/efectos adversos , Masculino , Femenino , Niño , Bombas de Infusión Implantables/efectos adversos , Factores de Riesgo , Relajantes Musculares Centrales/administración & dosificación , Estudios Retrospectivos , Adolescente , Parálisis Cerebral/cirugía , Parálisis Cerebral/complicaciones , Preescolar , Espasticidad Muscular/tratamiento farmacológico , Espasticidad Muscular/etiología , Espasticidad Muscular/cirugía , Reoperación/métodos , Inyecciones Espinales/métodos , Resultado del Tratamiento , Complicaciones Posoperatorias/etiología , Falla de Equipo , Estudios de Cohortes