Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Adv Mater Interfaces ; 8(3)2021 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-33598379

RESUMEN

2D nanomaterials have long been considered for development of high permeability membranes. However, current processes have yet to yield a viable membrane for practical use due to the lack of scalability and substantial performance improvements over existing membranes. Herein, an ultrathin graphene oxide (GO) membrane with a permeability of 1562 mL h-1 mmHg-1 m-2, two orders of magnitude higher than the existing nanofiltration membranes, and a tight molecular weight cut-off is presented. To build such a membrane, a new process involving self-assembly and optimization of GO nanoplatelet physicochemical properties is developed. The process produces a highly organized mosaic of nanoplatelets enabling ultra-high permeability and selectivity. An adjustable molecular interlinker between the layers enables absolute nanometer-scale size cut-offs. These characteristics promise significant improvements to many nanoparticle and biological separation applications. In this work, the performance of the membrane in blood dialysis scenarios is evaluated. Urea and cytochrome-c sieving coefficients of 0.5 and 0.4 are achieved while retaining 99% of albumin. Hemolysis, complement activation, and coagulation studies exhibit a performance on par or superior to the existing dialysis membrane materials.

2.
ACS Biomater Sci Eng ; 6(2): 959-968, 2020 02 10.
Artículo en Inglés | MEDLINE | ID: mdl-32582838

RESUMEN

Porous membranes are ubiquitous in cell co-culture and tissue-on-a-chip studies. These materials are predominantly chosen for their semi-permeable and size exclusion properties to restrict or permit transmigration and cell-cell communication. However, previous studies have shown pore size, spacing and orientation affect cell behavior including extracellular matrix production and migration. The mechanism behind this behavior is not fully understood. In this study, we fabricated micropatterned non-fouling polyethylene glycol (PEG) islands to mimic pore openings in order to decouple the effect of surface discontinuity from potential grip on the vertical contact area provided by pore wall edges. Similar to previous findings on porous membranes, we found that the PEG islands hindered fibronectin fibrillogenesis with cells on patterned substrates producing shorter fibrils. Additionally, cell migration speed over micropatterned PEG islands was greater than unpatterned controls, suggesting that disruption of cell-substrate interactions by PEG islands promoted a more dynamic and migratory behavior, similarly to enhanced cell migration on microporous membranes. Preferred cellular directionality during migration was nearly indistinguishable between substrates with identically patterned PEG islands and previously reported behavior over micropores of the same geometry, further confirming disruption of cell-substrate interactions as a common mechanism behind the cellular responses on these substrates. Interestingly, compared to respective controls, there were differences in cell spreading and a lower increase in migration speed over PEG islands compared prior results on micropores with identical feature size and spacing. This suggests that membrane pores not only disrupt cell-substrate interactions, but also provide additional physical factors that affect cellular response.


Asunto(s)
Células Endoteliales , Polietilenglicoles , Fenómenos Biofísicos , Islas , Membranas
3.
Cell Mol Bioeng ; 13(2): 125-139, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32175026

RESUMEN

INTRODUCTION: The pathophysiological increase in microvascular permeability plays a well-known role in the onset and progression of diseases like sepsis and atherosclerosis. However, how interactions between neutrophils and the endothelium alter vessel permeability is often debated. METHODS: In this study, we introduce a microfluidic, silicon-membrane enabled vascular mimetic (µSiM-MVM) for investigating the role of neutrophils in inflammation-associated microvascular permeability. In utilizing optically transparent silicon nanomembrane technology, we build on previous microvascular models by enabling in situ observations of neutrophil-endothelium interactions. To evaluate the effects of neutrophil transmigration on microvascular model permeability, we established and validated electrical (transendothelial electrical resistance and impedance) and small molecule permeability assays that allow for the in situ quantification of temporal changes in endothelium junctional integrity. RESULTS: Analysis of neutrophil-expressed ß1 integrins revealed a prominent role of neutrophil transmigration and basement membrane interactions in increased microvascular permeability. By utilizing blocking antibodies specific to the ß1 subunit, we found that the observed increase in microvascular permeability due to neutrophil transmigration is constrained when neutrophil-basement membrane interactions are blocked. Having demonstrated the value of in situ measurements of small molecule permeability, we then developed and validated a quantitative framework that can be used to interpret barrier permeability for comparisons to conventional Transwell™ values. CONCLUSIONS: Overall, our results demonstrate the potential of the µSiM-MVM in elucidating mechanisms involved in the pathogenesis of inflammatory disease, and provide evidence for a role for neutrophils in inflammation-associated endothelial barrier disruption.

4.
Exp Cell Res ; 373(1-2): 198-210, 2018 12 15.
Artículo en Inglés | MEDLINE | ID: mdl-30399373

RESUMEN

Cell migration is essential to many life processes, including immune response, tissue repair, and cancer progression. A reliable quantitative characterization of the cell migration can therefore aid in the high throughput screening of drug efficacy in wound healing and cancer treatments. In this work, we report what we believe is the first use of SiR-Hoechst for extended live tracking and automated analysis of cell migration and wound healing. We showed through rigorous statistical comparisons that this far-red label does not affect migratory behavior. We observed excellent automated tracking of random cell migration, in which the motility parameters (speed, displacement, path length, directionality ratio, persistence time, and direction autocorrelation) obtained closely match those obtained from manual tracking. We also present an analysis framework to characterize the healing of a scratch wound from the perspective of single cells. The use of SiR-Hoechst is advantageous for the crowded environments in wound healing assays because as long as cell nuclei do not overlap, continuous tracking can be maintained even if there is cell-cell contact. In this paper, we report wound recovery based on the number of cells migrating into the wound over time, normalized by the initial cell count prior to the infliction of the wound. This normalized cell count approach is impervious to operator bias during the arbitration of wound edges and is also robust against variability that arises due to differences in the cell density of different samples. Additional wound healing characteristics were also defined based on the evolution of cell speed and directionality during healing. Not unexpected, the wound healing cells exhibited much higher tendency to maintain the same migratory direction in comparison to the randomly migrating cells. The use of SiR-Hoechst thus greatly simplified the automation of single cell and whole population analysis with high spatial and temporal resolution over extended periods of time.


Asunto(s)
Movimiento Celular , Rastreo Celular , Colorantes Fluorescentes , Cicatrización de Heridas , Adulto , Células Cultivadas , Humanos
5.
Lab Chip ; 18(12): 1671-1689, 2018 06 12.
Artículo en Inglés | MEDLINE | ID: mdl-29845145

RESUMEN

Porous membranes enable the partitioning of cellular microenvironments in vitro, while still allowing physical and biochemical crosstalk between cells, a feature that is often necessary for recapitulating physiological functions. This article provides an overview of the different membranes used in tissue barrier and cellular co-culture models with a focus on experimental design and control of these systems. Specifically, we discuss how the structural, mechanical, chemical, and even the optical and transport properties of different membranes bestow specific advantages and disadvantages through the context of physiological relevance. This review also explores how membrane pore properties affect perfusion and solute permeability by developing an analytical framework to guide the design and use of tissue barrier or co-culture models. Ultimately, this review offers insight into the important aspects one must consider when using porous membranes in tissue barrier and lab-on-a-chip applications.


Asunto(s)
Técnicas de Cocultivo , Membranas Artificiales , Modelos Biológicos , Ingeniería de Tejidos , Animales , Línea Celular , Humanos , Ratones , Porosidad , Técnicas de Cultivo de Tejidos
6.
ACS Biomater Sci Eng ; 4(1): 222-230, 2018 Jan 08.
Artículo en Inglés | MEDLINE | ID: mdl-29713681

RESUMEN

Porous substrates have gained increased usage in cell studies and tissue mimetic applications because they can partition distinct cell types while still allowing important biochemical crosstalk. In the presented work, we investigated how porous substrates with micron and submicron features influence early cell migration and the associated ECM establishment, which can critically affect the rate of cell coverage on the substrate and the ensuing tissue organization. We showed through time-lapse microscopy that cell speed and migratory distance on membranes with 0.5 µm pores were nearly two-fold of those observed on nonporous membranes, while values on membranes with 3.0 µm pores fell in between. Although the cell directionality ratio and the persistence time was unaffected by the presence of pores, the cells did exhibit directionality preferences based on the hexagonal pore patterning. Fibronectin fibrillogenesis exhibited a distinct inverse relationship to cell speed, as the fibrils formed on the nonporous control were significantly longer than those on both types of porous substrates. We further confirmed on a per cell basis that there is a negative correlation between fibronectin fibril length and cell speed. The observed trade-off between early cell coverage and ECM establishment thus warrants consideration in the selection or the engineering of the ideal porous substrate for tissue mimetic applications and may help guide future cell studies.

7.
ACS Biomater Sci Eng ; 3(3): 243-248, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28993815

RESUMEN

Mechanical cues and substrate interaction affect the manner in which cells adhere, spread, migrate and form tissues. With increased interest in tissue-on-a-chip and co-culture systems utilizing porous membranes, it is important to understand the role of disrupted surfaces on cellular behavior. Using a transparent glass membrane with defined pore geometries, we investigated endothelial fibronectin fibrillogenesis and formation of focal adhesions as well as development of intercellular junctions. Cells formed fewer focal adhesions and had shorter fibronectin fibrils on porous membranes compared to non-porous controls, which was similar to cell behavior on continuous soft substrates with Young's moduli seven orders of magnitude lower than glass. Additionally, porous membranes promoted enhanced cell-cell interactions as evidenced by earlier formation of tight junctions. These findings suggest that porous membranes with discontinuous surfaces promote reduced cell-matrix interactions similarly to soft substrates and may enhance tissue and barrier formation.

8.
Lab Chip ; 14(14): 2456-68, 2014 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-24850320

RESUMEN

Microfluidic systems are powerful tools for cell biology studies because they enable the precise addition and removal of solutes in small volumes. However, the fluid forces inherent in the use of microfluidics for cell cultures are sometimes undesirable. An important example is chemotaxis systems where fluid flow creates well-defined and steady chemotactic gradients but also pushes cells downstream. Here we demonstrate a chemotaxis system in which two chambers are separated by a molecularly thin (15 nm), transparent, and nanoporous silicon membrane. One chamber is a microfluidic channel that carries a flow-generated gradient while the other chamber is a shear-free environment for cell observation. The molecularly thin membranes provide effectively no resistance to molecular diffusion between the two chambers, making them ideal elements for creating flow-free chambers in microfluidic systems. Analytical and computational flow models that account for membrane and chamber geometry, predict shear reduction of more than five orders of magnitude. This prediction is confirmed by observing the pure diffusion of nanoparticles in the cell-hosting chamber despite high input flow (Q = 10 µL min(-1); vavg ~ 45 mm min(-1)) in the flow chamber only 15 nm away. Using total internal reflection fluorescence (TIRF) microscopy, we show that a flow-generated molecular gradient will pass through the membrane into the quiescent cell chamber. Finally we demonstrate that our device allows us to expose migrating neutrophils to a chemotactic gradient or fluorescent label without any influence from flow.


Asunto(s)
Quimiotaxis/fisiología , Membranas Artificiales , Técnicas Analíticas Microfluídicas , Neutrófilos , Silicio/química , Coloración y Etiquetado , Humanos , Técnicas Analíticas Microfluídicas/instrumentación , Técnicas Analíticas Microfluídicas/métodos , Neutrófilos/citología , Neutrófilos/metabolismo , Coloración y Etiquetado/instrumentación , Coloración y Etiquetado/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...