Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
Anal Bioanal Chem ; 412(15): 3703-3716, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32246180

RESUMO

In this work, the suitability of atmospheric pressure photoionization (APPI) has been assessed for the determination of polychlorinated dibenzo-p-dioxins and furans (PCDD/Fs) and dioxin-like polychlorinated biphenyls (dl-PCBs) by gas chromatography-high-resolution mass spectrometry (GC-HRMS). The APPI of target compounds has been tested in both positive and negative ion modes. Under positive ion mode, the analytes generated the molecular ion, which was favoured using dopants that promote charge exchange gas-phase reactions (i.e., benzene), while in negative ion mode, the ion [M-Cl+O]- for PCDFs and dl-PCBs were mainly formed, providing the best results using benzene and diethyl ether as dopants, respectively. Concerning PCDDs, highly chlorinated congeners were mainly ionized by means of the [M-Cl]- ion, whereas [M-Cl+O2]- was the base peak for tetraCDD and [M-Cl+O]- for penta- and hexaCDDs. Method quality parameters, in accordance with the current EU Regulation guidelines for food and feed analysis, showed the good performance of the two GC-APPI-HRMS (Orbitrap) methods since they provided high detection capability (low fg levels), good linearity, and satisfactory precision (RSD% < 9%). In addition, the GC-APPI-HRMS (Orbitrap) methods were validated by analysing selected environmental and feed samples and the results were compared to those obtained using conventional GC-EI-HRMS, demonstrating the good performance in the analysis of the target compounds. Hence, the GC-APPI-HRMS technique can be proposed as alternative to the conventional methods for the determination of PCDD/Fs and dl-PCBs in environmental and feed matrices.


Assuntos
Dibenzofuranos/análise , Poluentes Ambientais/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Bifenilos Policlorados/análise , Dibenzodioxinas Policloradas/análise , Pressão Atmosférica , Dioxinas/análise , Monitoramento Ambiental/métodos , Estudos de Viabilidade , Análise de Alimentos/métodos
2.
Epidemiol Infect ; 148: e12, 2020 01 27.
Artigo em Inglês | MEDLINE | ID: mdl-31983356

RESUMO

Neisseria meningitidis, a gram-negative diplococcus, is typically an asymptomatic coloniser of the oropharynx and nasopharynx. Passage of N. meningitidis into the bloodstream can cause invasive meningococcal disease (IMD), a potentially life-threatening illness with rapid onset that generally presents as meningitis, septicemia or both. Serogroup W IMD has been increasing in prevalence in recent years, and observations suggest that it may present with atypical signs and symptoms. Herein, a literature search was performed to identify trends in atypical serogroup W IMD presentation in order to review those that are most prevalent. Findings indicate that the most prevalent atypical presentations of serogroup W IMD include acute gastrointestinal (GI) symptoms, septic arthritis and bacteremic pneumonia or severe upper respiratory tract infection, notably epiglottitis. Atypical clinical presentation is associated with higher case fatality rates and can lead to misdiagnoses. Such risks highlight the need for clinicians to consider IMD in their differential diagnoses of patients with acute GI symptoms, septic arthritis or bacteremic pneumonia, primarily in regions where serogroup W is prevalent.


Assuntos
Meningite Meningocócica/microbiologia , Meningite Meningocócica/patologia , Neisseria meningitidis/classificação , Neisseria meningitidis/isolamento & purificação , Sepse/microbiologia , Sepse/patologia , Sorogrupo , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Meningite Meningocócica/mortalidade , Pessoa de Meia-Idade , Prevalência , Sepse/mortalidade , Adulto Jovem
3.
J Geophys Res Atmos ; 124(13): 6669-6680, 2019 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-31632893

RESUMO

Substantial increases in the atmospheric concentration of well-mixed greenhouse gases (notably CO2), such as those projected to occur by the end of the 21st century under large radiative forcing scenarios, have long been known to cause an acceleration of the Brewer-Dobson circulation (BDC) in climate models. More recently, however, several single-model studies have proposed that ozone-depleting substances might also be important drivers of BDC trends. As these studies were conducted with different forcings over different periods, it is difficult to combine them to obtain a robust quantitative picture of the relative importance of ozone-depleting substances as drivers of BDC trends. To this end we here analyze - over identical past and future periods - the output from 20 similarly-forced models, gathered from two recent chemistry-climate modeling intercomparison projects. Our multi-model analysis reveals that ozone-depleting substances are responsible for more than half of the modeled BDC trends in the two decades 1980-2000. We also find that, as a consequence of the Montreal Protocol, decreasing concentrations of ozone-depleting substances in coming decades will strongly decelerate the BDC until the year 2080, reducing the age-of-air trends by more than half, and will thus substantially mitigate the impact of increasing CO2. As ozone-depleting substances impact BDC trends, primarily, via the depletion/recovery of stratospheric ozone over the South Pole, they impart seasonal and hemispheric asymmetries to the trends which may offer opportunities for detection in coming decades.

4.
Sci Total Environ ; 633: 738-744, 2018 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-29602112

RESUMO

Reductions in concentrations of persistent organic pollutants were observed for polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in a comparison of two consecutive decades ending in December 31, 2015 (n = 413) and compiled from a 48-station long-term air-monitoring network in Catalonia, Spain. Reductions were observed in geometric mean concentration of total PCDD/Fs, decreasing at a rate of 11% yr-1. Results reflect the relative success of improved pollution control measures at industry and traffic locations. At traffic and industrial locations, PCDD/Fs were reduced by around 68% (from 70 to 22 fg I-TEQ/m3) and 66% (from 57 to 19 fg I-TEQ/m3), respectively. The highest concentration of 1196 fg I-TEQ/m3 was observed during the first decade at an industrial location. The highest concentration over the second decade was at a background location during winter (674 fg I-TEQ/m3). Winter observations are generally higher than those recorded in summer, as evident in an 8-year period of moderate PCDD/F levels (<250 fg I-TEQ/m3, n = 143). PCDD/F congener profiles were identified has having less chlorinated PCDD/F, indicating the presence of nearby combustion sources at selected locations. More long-term sampling campaigns, combined with network optimization and integration into a meteorological model, can offer a tool for future PCDD/Fs control measures in not only Catalonia - but also applicable to other areas.

5.
J Chromatogr A ; 1513: 245-249, 2017 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-28735712

RESUMO

A gas chromatography coupled to triple-quadrupole mass spectrometry (GC-(QqQ)MS/MS) including a soft-ionization through an atmospheric pressure chemical ionization (APCI) source based method was compared with the high resolution mass spectrometry (HRMS) standard reference method EN1948, for the analysis of polychlorinated dibenzo-p-dioxins and furans (PCDD/Fs) in stack gas emissions. The stack emission samples were collected, both, by manual method sampling (from 6 to 8h) and by long-term sampling systems (sampling time of several weeks). This work presents the first comparison of GC-(QqQ)MS/MS with APCI source with the European Standard EN1948 technique for stack gas emissions. Sample concentrations ranged from 0.5 to 596pg I-TEQ/Nm3. Comparative results in all investigated samples showed relative errors that were within ±15%. These results make GC-(QqQ)MS/MS with APCI suitable for the quantitative analysis of dioxins in the studied samples and create a real alternative tool to the reference sector GC-HRMS instruments.


Assuntos
Pressão Atmosférica , Dibenzofuranos/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Dibenzodioxinas Policloradas/análise , Incineração , Limite de Detecção , Resíduos Sólidos/análise , Espectrometria de Massas em Tandem/métodos
6.
Anal Chim Acta ; 937: 96-105, 2016 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-27590550

RESUMO

The use of the novel atmospheric pressure chemical ionization (APCI) source for gas chromatography (GC) coupled to triple quadrupole using tandem mass spectrometry (MS/MS) and its potential for the simultaneous determination of the 12 dioxin-like polychlorobiphenyls (DL-PCBs) in complex food and feed matrices has been evaluated. In first place, ionization and fragmentation behavior of DL-PCBs on the APCI source under charge transfer conditions has been studied followed by their fragmentation in the collision cell. Linearity, repeatability and sensitivity have been studied obtaining instrumental limits of detection and quantification of 0.0025 and 0.005 pg µL(-1) (2.5 and 5 fg on column) respectively for every DL-PCB. Finally, application to real samples has been carried out and DL-PCB congeners (PCB 77, 81, 105, 114, 118, 123, 126, 156, 157, 167, 169, 189) have been detected in the different samples in the range of 0.40-10000 pg g(-1). GC-(APCI)MS/MS has been proved as a suitable alternative to the traditionally accepted confirmation method based on the use of high resolution mass spectrometry and other triple quadrupole tandem mass spectrometry techniques operating with electron ionization. The development of MS/MS methodologies for the analysis of dioxins and DL-PCBs is nowadays particularly important, since this technique was included as a confirmatory method in the present European Union regulations that establish the requirements for the determination of these compounds in food and feed matrices.


Assuntos
Pressão Atmosférica , Dioxinas/análise , Contaminação de Alimentos/análise , Hidrocarbonetos Clorados/análise , Polímeros/análise , Cromatografia Gasosa , Espectrometria de Massas em Tandem
7.
Sci Total Environ ; 568: 1185-1191, 2016 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-27173454

RESUMO

Polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and dioxin-like polychlorinated biphenyls (dl-PCBs) are commonly known as dioxins and are the most toxic members of persistent organic pollutants (POPs) because present a variety of health effects especially as promoting agent of growing and transformation of cancer cells. They are bio-accumulate in humans primarily via the diet, specifically by ingestion of foods that have high lipid content which are generally associated with foods of animal origin such as oils and fats and with fishery and dairy products. In Colombia the Ministry of Health and Social Protection which is the entity responsible for surveillance food conditions, has established maximum levels for dioxins and dl-PCBs in oils from animal and vegetable origins. Oils of vegetable and animal origin represent an appreciable intake in the country thus the presence of dioxins and dl-PCBs in these materials is a matter of concern because they can bioaccumulate in fat. In this contribution the levels of PCDD/Fs and dl-PCBs in olive, soybean, fish oil, butter and shrimp consumed in Colombia were determined using HRGC-HRMS and were compared with the maximum levels permitted in oil samples according to both the Colombian and European regulations. WHO-TEQ concentrations for PCDD/Fs and dioxin like PCBs ranged from 0.24 to 1.710pgWHO-TEQ PCDD/Fg(-1) of fat and from 0.050 to 3.000pgWHO-TEQ PCBg(-1) of fat, respectively. As expected, fish oils and shrimp present the highest WHO-TEQ PCDD/Fs and dl-PCBs values followed by butter and soybean oil sample, while the olive oil shows the lowest levels. In general, the vegetable oils show levels below the limits established by both the Colombian and European regulations. The levels from soybean oil found in this study were slightly higher than the threshold established both by the Commission Regulation European Union (EU) and the Colombian legislation, while fish oils showed concentrations above the European regulations. Furthermore, shrimp exhibited values below the maximum concentration levels established by the EU and Colombian regulation.


Assuntos
Benzofuranos/análise , Dioxinas/análise , Poluentes Ambientais/análise , Contaminação de Alimentos/análise , Dibenzodioxinas Policloradas/análise , Animais , Manteiga/análise , Colômbia , Crustáceos/química , Óleos de Peixe/análise , Óleos de Plantas/análise
8.
Sci Total Environ ; 568: 614-623, 2016 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-26953138

RESUMO

Passive air-sampling data of polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and dioxin-like polychlorinated biphenyls (dl-PCBs) taken in Manizales (a medium-sized city) and Bogotá (a megacity), Colombia, were analyzed in order to identify potential sources of pollution and the possible influence of meteorological variables like temperature and precipitation. The results indicate important differences in levels of PCDD/Fs and dl-PCBs between Bogotá and Manizales, attributed to differences in site characteristics and potential local/regional sources. Higher PCDD/Fs concentrations were observed in Bogotá (373fg/m(3)) compared to those observed in Manizales, with mean levels ranging from 64fg/m(3) in a residential zone to 151fg/m(3) around a vehicular-influenced area. Higher dl-PCBs concentrations were observed in the industrial area of Manizales compared to those observed in Bogotá, with mean levels of 6668fg/m(3) and 4388fg/m(3) respectively. In terms of PCDD/Fs congener distribution, there was a predominance of octachlorodibenzodioxin (OCDD) followed by 1,2,3,4,6,7.8-heptachlorodibenzofuran (HpCDF) congeners, with both cities showing higher levels in zones of high vehicular activity. Industrial influence was most evident in dl-PCB levels. In comparison to the mean levels of dl-PCB congeners obtained in the vehicular zones of Bogotá and Manizales, the industrially influenced sampling stations showed higher concentrations of dl-PCB congeners. Passive sampling results suggested that congener concentration profiles are characteristic of their different emission sources, and can be used to distinguish between their industrial or vehicular origins.


Assuntos
Poluentes Atmosféricos/análise , Dibenzofuranos Policlorados/análise , Monitoramento Ambiental/métodos , Bifenilos Policlorados/análise , Dibenzodioxinas Policloradas/análise , Cidades , Colômbia , Indústrias , Clima Tropical
9.
Sci Total Environ ; 485-486: 528-533, 2014 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-24742561

RESUMO

The aim of this work is to characterize atmospheric emissions of polychlorinated dibenzo-p-dioxins (PCDDs)/polychlorinated dibenzofurans (PCDFs) and dioxin-like polychlorinated biphenyls (dl-PCBs) from a cement production plant where the existing clinker production line was completely replaced by a new state-of-the-art installation. The project started in April 2008 with the installation of a long-term sampling system in the stack of the clinker kiln that used petroleum coke as fuel; PCDD/PCDF and dl-PCB emissions were then evaluated for a two year period. To carry out the second part of the study, in 2010 the sampling system was moved to the new installation in which, apart from conventional fuel, recovered derived fuel (RDF) and WWTP sludge were used as alternative fuels. For both the old and new clinker kilns, PCDD/PCDF emission values were well below the limit established by the European Waste Incineration Directive 2000/76/CE (EWID) of 100 pg I-TEQ/Nm(3); values ranged from 0.43 to 2.02 and from 0.07 to 3.31 pg I-TEQ/Nm(3), respectively. dl-PCBs accounted for approximately 25% of the WHO-TEQ toxicity. These results prove that the installation is capable of reducing PCDD/PCDF and dl-PCB emissions when alternative fuels are integrated into the process. In the case of PCDDs/PCDFs, the major contributions to total TEQ were usually from 2,3,7,8-TCDD (owing to its relative abundance) and 2,3,4,7,8-PeCDF (due to its high I-TEF of 0.5); while for dl-PCBs, the major contribution was from PCB-126. The slight shift in the congener profile between the old and new installations was characterized and a regression model was proposed for dl-PCB emissions depending on the RDF flow rate in the clinker.


Assuntos
Poluentes Atmosféricos/análise , Coque , Dioxinas/análise , Incineração , Poluição do Ar/estatística & dados numéricos , Monitoramento Ambiental
10.
Sci Total Environ ; 491-492: 67-74, 2014 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-24555963

RESUMO

Concentration gradients were observed in gas and particulate phases of PCDD/F originating from industrial and vehicular sources in the densely populated tropical Andean city of Manizales, using passive and active air samplers. Preliminary results suggest greater concentrations of dl-PCB in the mostly gaseous fraction (using quarterly passive samplers) and greater concentrations of PCDD/F in the mostly particle fraction (using daily active samplers). Dioxin-like PCB predominance was associated with the semi-volatility property, which depends on ambient temperature. Slight variations of ambient temperature in Manizales during the sampling period (15°C-27°C) may have triggered higher concentrations in all passive samples. This was the first passive air sampling monitoring of PCDD/F conducted in an urban area of Colombia. Passive sampling revealed that PCDD/F in combination with dioxin-like PCB ranged from 16 WHO-TEQ2005/m(3) near industrial sources to 7 WHO-TEQ2005/m(3) in an intermediate zone-a reduction of 56% over 2.8 km. Active sampling of particulate phase PCDD/F and dl-PCB were analyzed in PM10 samples. PCDD/F combined with dl-PCB ranged from 46 WHO-TEQ2005/m(3) near vehicular sources to 8 WHO-TEQ2005/m(3) in the same intermediate zone, a reduction of 83% over 2.6 km. Toxic equivalent quantities in both PCDD/F and dl-PCB decreased toward an intermediate zone of the city. Variations in congener profiles were consistent with variations expected from nearby sources, such as a secondary metallurgy plant, areas of concentrated vehicular emissions and a municipal solid waste incinerator (MSWI). These variations in congener profile measurements of dioxins and dl-PCBs in passive and active samples can be partly explained by congener variations expected from the various sources.


Assuntos
Poluentes Atmosféricos/análise , Benzofuranos/análise , Dioxinas/análise , Monitoramento Ambiental/métodos , Bifenilos Policlorados/análise , Dibenzodioxinas Policloradas/análogos & derivados , Polímeros/análise , Poluição do Ar/estatística & dados numéricos , Cidades/estatística & dados numéricos , Colômbia , Incineração , Indústrias/estatística & dados numéricos , Dibenzodioxinas Policloradas/análise , Emissões de Veículos/análise
11.
Chemosphere ; 93(3): 499-505, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23859426

RESUMO

The results of a surveillance programme on the determination of polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), polychlorinated biphenyls (PCBs), polybrominated diphenyl ethers (PBDEs) and short chain chlorinated paraffins (SCCPs) in marine fish and shellfish species which are fished, commercialised and consumed in the Ebro River Delta area (NE, Spain) are presented. The study included the analysis of five marine fish species (sardine, gilthead sea bream, conger, eel and flounder) and three shellfish species (murex, carpet shell and mussel) collected in 2012 in five fishing harbours near to this area. WHO-TEQ concentrations for PCDD/Fs and dioxin like PCBs (dl-PCBs) ranged from 0.03 to 0.31 pg WHO-TEQ2005PCDD/Fg(-1)wetweight (ww) and from 0.02 to 3.15 pg WHO-TEQ2005PCBg(-1)ww, respectively. All levels were below the maximum concentrations established by the EU Regulation. The PCBs and PCDD/Fs accumulation pattern found in the samples analysed showed a distribution typically reported for marine samples. For marker PCBs and PBDEs, concentration levels ranging from 929 to 57494 pg g(-1)ww and from 36.2 to 827 pg g(-1)ww were obtained, respectively, meanwhile for SCCPs levels were between 3.1 and 141 ng g(-1)ww. Finally, the trends in the levels of PCDD/F and dl-PCBs found from 2006 to 2012 in fish and shellfish species were studied. A slight decrease of PCDD/F and dl-PCB concentrations was found since 2006.


Assuntos
Exposição Ambiental , Peixes/metabolismo , Moluscos/metabolismo , Alimentos Marinhos/análise , Poluentes Químicos da Água/metabolismo , Animais , Benzofuranos/metabolismo , Dibenzofuranos Policlorados , Monitoramento Ambiental , Estuários , Produtos Pesqueiros/análise , Cromatografia Gasosa-Espectrometria de Massas , Éteres Difenil Halogenados/metabolismo , Hidrocarbonetos Clorados/metabolismo , Estações do Ano , Espanha
12.
Sci Total Environ ; 435-436: 7-13, 2012 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-22842592

RESUMO

In this work, a reliable methodology for the simultaneous analysis of PCDD/PCDF and dioxin-like PCB (dl-PCB) in flue gas emissions collected using continuous sampling devices is proposed. The analytical scheme followed the minimum requirements described in the EU standard EN-1948:1,2,3,4 according to samples containing large amounts of dioxins and dl-PCBs or samples collected over a long period of time of about 4 weeks. Parameters, such as reproducibility, precision, limits of detection (LOD), limits of quantification (LOQ), extract aliquot size, analytical blanks, extraction efficiency, as well as the amount of internal standards required for an accurate determination, were assessed. The findings demonstrate the suitability of the proposed analytical scheme for the analysis of PCDD/PCDF and PCB in samples collected using long-term sampling devices. The analysis of five different 5% v/v sample aliquots reported %RSD values lower than 10% for all of the 29 congeners at both low and high levels. Similarly, %RSD values were 3.2 and 2.0 for the low level samples and 0.9 and 1.1%RSD for the high level extracts for PCDD/PCDF and dl-PCB, respectively expressed in total TEQ units. Re-extraction provided values less than 3%, expressed in TEQ. Based on blank analyses, LOD values of 100 pg I-TEQ for PCDD/PCDF and 10 pg WHO-TEQ for dl-PCB were achieved when 5% v/v aliquots were analyzed. Finally, the proposed analytical approach was tested with samples from a wide range of combustion processes such as hazardous and municipal waste incinerators, as well as cement kilns (with and without waste co-incineration).


Assuntos
Poluentes Atmosféricos/análise , Dioxinas/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Bifenilos Policlorados/análise , Dibenzodioxinas Policloradas/análogos & derivados , Cromatografia Gasosa-Espectrometria de Massas/instrumentação , Incineração , Dibenzodioxinas Policloradas/análise , Reprodutibilidade dos Testes
13.
Chemosphere ; 85(2): 170-8, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21745682

RESUMO

Particle-bound polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) in ambient air were monitored together with particulate matter less than 10 µm (PM(10)) at three sampling sites of the Andean city of Manizales, Colombia; during September 2009 and July 2010. PCDD/Fs ambient air emissions ranged from 1 fg WHO-TEQ m(-3) to 52 fg WHO-TEQ m(-3) in particulate fraction. The PM(10) concentrations ranged from 23 µg m(-3) to 54 µg m(-3). Concentrations of PM(10) and PCDD/Fs in ambient air observed for Manizales - a medium sized city with a population of 380,000 - were comparable to concentrations in larger cities. The highest concentrations of PCDD/Fs and PM(10) found in this study were determined at the central zone of the city, characterized by public transportation density, where diesel as principal fuel is used. In addition, hypothetical gas fractions of PCDD/Fs were calculated from theoretical K(p) data. Congener profiles of PCDD/Fs exhibited ratios associated with different combustion sources at the different sampling locations, ranging from steel recycling to gasoline and diesel engines. Taking into account particle and gas hypothetical fraction of PCDD/Fs, Manizales exhibited values of PCDD/Fs equivalent to rural and urban-industrial sites in the southeast and center of the city respectively. Poor correlation of PCDDs with PM(10) (r=-0.55 and r=0.52) suggests ambient air PCDDs were derived from various combustion sources. Stronger correlation was observed of PCDFs with PM(10). Poor correlation between precipitation and reduced PM(10) concentration in ambient air (r=-0.45) suggested low PM(10) removal by rainfall.


Assuntos
Poluentes Atmosféricos/análise , Benzofuranos/análise , Dibenzodioxinas Policloradas/análogos & derivados , Cidades , Colômbia , Dibenzofuranos Policlorados , Monitoramento Ambiental , Dibenzodioxinas Policloradas/análise , Chuva
14.
Chemosphere ; 82(9): 1343-9, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21193220

RESUMO

The aim of this work is to evaluate the performance of a continuous monitoring system for the analysis of the mass concentration of PCDD/Fs from stationary sources. Data was acquired from a modern, state of the art, hazardous waste thermal treatment plant for a period of more than 2 years using a commercial available continuous monitoring system. The study consisted of a total of 16 samples, collected in periods from 1 week to 2 months resulting in an average of 360 m³ sampled flue gas per sample. The study showed the system was able to confirm that for a period of more than 2 years the plant was complying with the limit of 0.1 ng I-TEQ/Nm(3). In addition, the data showed the typical fingerprint of such installations which is useful for example in impact studies. Long-term samples were compared to five short-term samples (6 h) collected every 6 months during the study period. Principal component analysis was applied to PCDD/Fs obtained data as useful statistical tool to find out trends and similarities between different samples. Improvement in terms of representativeness of data was achieved through continuous assessment since the starts of the project. The obtained data was further used to determine the emission factor for this activity and the total annual PCDD/Fs release to the atmosphere.


Assuntos
Poluentes Atmosféricos/análise , Benzofuranos/análise , Monitoramento Ambiental/métodos , Incineração , Dibenzodioxinas Policloradas/análogos & derivados , Poluentes Atmosféricos/química , Poluição do Ar/estatística & dados numéricos , Benzofuranos/química , Dibenzofuranos Policlorados , Cromatografia Gasosa-Espectrometria de Massas , Dibenzodioxinas Policloradas/análise , Dibenzodioxinas Policloradas/química , Espanha
15.
Anal Chim Acta ; 678(1): 73-81, 2010 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-20869507

RESUMO

A one-step extraction and clean-up method using pressurized liquid extraction (PLE) (selective PLE) combined with gas chromatography-ion-trap tandem mass spectrometry (GC-ITMS-MS) was evaluated for the analysis of polybrominated diphenyl ethers (from tri- to hepta-PBDEs) at low concentrations in fish and shellfish samples. To this end, the performance of an on-line PLE extraction/clean-up method and of a classical Soxhlet extraction and clean-up method using a multi-layer modified silica column were compared. The two sample treatment methods provided similar results, although an important reduction in the sample treatment time (40 min per sample) was achieved using the selective PLE method. In addition, the suitability of the PLE combined with GC-ITMS-MS method was evaluated by comparing the results obtained in the analysis of fish samples with those obtained by gas chromatography-high resolution mass spectrometry (GC-HRMS). Good agreement between both techniques was obtained with differences between the mean values of less than 16%. The selective PLE method coupled to GC-ITMS-MS produced accurate results for PBDE determination with low limits of detection (1.0-16.8 pg g(-1) wet weight) and quantification (3.1-51 pg g(-1) wet weight) as well as good precision (RSD<16%). This method has been applied to the analysis of PBDEs in fish and shellfish samples collected at fish markets in Catalonia (NE Spain).

16.
J Chromatogr A ; 1216(31): 5888-94, 2009 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-19560773

RESUMO

The analysis of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) and dioxin-like polychlorinated biphenyls (dl-PCBs) present in stack gas emissions and solid residues from incinerators will be mandatory in the foreseeable future. European standard EN-1948 is in the process of being updated through the addition of a new Part 4 related to the analysis of the 12 dl-PCBs. Therefore, either a comprehensive and reliable method capable of analyzing all of these 29 compounds (12 dl-PCBs and 17 2,3,7,8-PCDD/Fs) needs to be developed, or the existing PCDD/F analytical procedure must be adapted to include the dl-PCBs. This study has taken the latter approach of modifying PCDD/F methodology and in particular the fractionation step, by isolating dioxins and dl-PCBs into separate fractions ready for high resolution gas chromatography coupled to high resolution mass spectrometry (HRGC/HRMS) analysis. Results obtained from the analysis of Certified Reference Materials (CRM-490 and CRM-615) and fly ashes from the European Committee for Standardization (CEN) intercalibration study demonstrated that the proposed methodology is appropriate to determine the dl-PCBs in accordance with the impending European standard EN-1948. Uncertainty values obtained during the validation of the analytical methodology were 13% total I-TEQ (International Toxic Equivalent) for PCDD/Fs and 31% total WHO-TEQ (World Health Organization Toxic Equivalent) in the case of dl-PCBs. In addition, 'real' samples such as emissions and fly ashes were successfully analyzed following the proposed analytical method.


Assuntos
Poluentes Atmosféricos/química , Benzofuranos/isolamento & purificação , Carbono/química , Cromatografia Gasosa-Espectrometria de Massas/métodos , Material Particulado/química , Bifenilos Policlorados/isolamento & purificação , Dibenzodioxinas Policloradas/análogos & derivados , Cinza de Carvão , União Europeia , Dibenzodioxinas Policloradas/isolamento & purificação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
17.
Artigo em Inglês | MEDLINE | ID: mdl-24784969

RESUMO

This study explored the potential use of seven congeners of polychlorinated biphenyls (PCBs-7) as indicator compounds for the presence of dioxins and PCBs in food samples, as part of the routine surveillance programme of a public health agency. Samples of 24 foodstuffs with high fat content were collected (ten fresh fish, six dairy products, five meat and three eggs). Duplicate analyses were performed. A research laboratory tested samples for seven polychlorinated dibenzo-p-dioxin (PCDDs), ten dibenzofurans (PCDFs) and twelve dioxin-like PCBs, with limits of detection in the range of ng kg(-1) (ppt). The public health services official control laboratory tested samples for PCBs-7, with a limit of quantification of 5 µg kg(-1) (ppb). The research laboratory detected the presence of dioxins and dioxin-like PCBs in all samples; fish samples had the highest levels (0.04-10.3 pg WHO-TEQ g(-1)). The public health service official control laboratory detected PCBs-7 only in five samples, which were all fish. Comparing the results in the two laboratories there seems to be an association between the detection of PCB-7 and the presence of higher levels of PCDD/Fs and dioxin-like PCBs. The use of PCB-7 as an indicator compound may be a practical surveillance strategy for those foodstuffs with higher concentrations of dioxin-like congeners.


Assuntos
Dioxinas/análise , Contaminação de Alimentos/análise , Bifenilos Policlorados/análise , Animais , Galinhas/metabolismo , Laticínios/análise , Laticínios/toxicidade , Dioxinas/toxicidade , Ingestão de Alimentos , Ovos/análise , Ovos/toxicidade , Monitoramento Ambiental , Poluentes Ambientais/análise , Poluentes Ambientais/toxicidade , Peixes/metabolismo , Análise de Alimentos/métodos , Humanos , Concentração Máxima Permitida , Carne/análise , Carne/toxicidade , Bifenilos Policlorados/toxicidade , Saúde Pública , Espanha
18.
Chemosphere ; 73(1 Suppl): S252-60, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18492599

RESUMO

Extraction of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) was evaluated in sepiolite matrices. Soxhlet extraction using different extracting strategies and acid treatment were tested. Acid treatment or Soxhlet extraction using a mixture of toluene:ethanol as solvent allowed to reach the minimum requirements for recovery rates. However, Soxhlet extraction using a mixture cyclohexane:toluene as extracting solvent did not allow to comply with these minimum requirements. Significant differences were obtained in TEQ units when acid treatment was applied in comparison to Soxhlet extraction. This fact can be explained because the use of drastic acid conditions allows removing strongly adsorbed analytes which can be uniquely extracted after a total destruction of the crystalline. On the contrary, Soxhlet extraction was not able to destroy the structure of sepiolite and as a consequence the PCDDs/Fs remain adsorbed in the internal structure of the mineral. A bioaccumulation study was also conducted to evaluate the transference of PCDDs/Fs from the sepiolite into the animal when fed with feed containing sepiolite. Four groups of chickens were exposed through diet to a control feed, feed with 3% w/w sepiolite, spiked feed contaminated with PCDDs/Fs and feed containing contaminated kaolinitic clay. Livers of animals were analyzed throughout the exposure period. Results of this trial showed that the performance of broilers was not affected by the presence of dioxins at levels tested, and chickens did not show any abnormal behaviour. Dioxins intentionally added to the diet were significantly absorbed and accumulated in liver, whereas the PCDDs/Fs from sepiolite were not available for chickens since livers from broilers fed 3% sepiolite presented similar WHO-TEQ values than those from broilers fed control diet.


Assuntos
Ração Animal , Benzofuranos/análise , Benzofuranos/farmacocinética , Aditivos Alimentares/química , Contaminação de Alimentos/análise , Dibenzodioxinas Policloradas/análogos & derivados , Adsorção , Animais , Benzofuranos/isolamento & purificação , Disponibilidade Biológica , Galinhas/metabolismo , Dibenzofuranos Policlorados , Estudos de Viabilidade , Aditivos Alimentares/administração & dosagem , Fígado/citologia , Fígado/metabolismo , Silicatos de Magnésio/análise , Silicatos de Magnésio/química , Dibenzodioxinas Policloradas/análise , Dibenzodioxinas Policloradas/isolamento & purificação , Dibenzodioxinas Policloradas/farmacocinética
19.
Chemosphere ; 73(1 Suppl): S171-5, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18485442

RESUMO

Background data of polychlorinated dibenzodioxin and dibenzofuran (PCDD/Fs) emissions from the incineration sector in Colombia are presented. Monitoring was carried out during a two-year period, 2003-2005. Twelve plants were sampled for stack gas emissions of dioxins and total solid particulate (TSP). Additionally, PCDD/Fs in several fly ash samples were analyzed. Most incinerators burned industrial refuse materials and medical residues. A wide range of PCDD/Fs emission levels were found. In particular, levels ranging from 6.9 to 343.8 ng I-TEQ/N m(3) were determined in plants without any air pollution control system (APCS). In contrast, 0.5-39.2 ng I-TEQ/N m(3) levels were found in plants with APCS while 8.5-67.5 ng I-TEQ/g were measured in fly ash samples. TSP values ranged from 14 to 448 mg/N m(3). This study also evaluated the impact of implementing different control systems in an incinerator. Finally, for comparison purposes several samples were analyzed by both high resolution gas chromatography coupled to high resolution mass spectrometry (HRGC-HRMS) and high resolution gas chromatography coupled to ion-trap low resolution mass spectrometry-mass spectrometry (HRGC-IT LRMS/MS). Overall, I-TEQ values deviated about 20-30% between both techniques.


Assuntos
Poluição do Ar/análise , Benzofuranos/análise , Incineração , Dibenzodioxinas Policloradas/análogos & derivados , Carbono/química , Cromatografia Gasosa , Cinza de Carvão , Colômbia , Dibenzofuranos Policlorados , Gases/química , Resíduos Industriais , Espectrometria de Massas , Material Particulado/química , Dibenzodioxinas Policloradas/análise , Padrões de Referência , Reprodutibilidade dos Testes , Fatores de Tempo
20.
Chemosphere ; 71(6): 1115-26, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18078979

RESUMO

Among the tasks included in the "Quality and safety of feeding fats obtained from co-products or by-products of the food chain" Project, supported by the European Union and included in the 6th Framework Program, a number of fats and oils collected as co- or by-products from the food chain were selected for the determination of polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and 'dioxin-like' polychlorinated biphenyls (DL-PCBs). In the majority of the cases these samples are currently employed as feed ingredients. Nevertheless, additional fats, which are forbidden for feedstuff purposes were also considered in this study. In general terms, fats and oils were classified taking into account their nature and the processes applied to obtain these co- or by-products. PCDD/F and DL-PCB levels were evaluated in a first group of samples composed of fish oils, animal fats and lecithins. As expected, fats and oils with an animal origin presented higher concentrations, expressed in pg WHO-TEQ/g, compared to the levels found in vegetable samples like lecithins. The category of fish oils had the highest values for both PCDD/Fs and the sum of PCDD/Fs and DL-PCBs, with some samples showing levels above the maximum established at the present legislation related to the presence of PCDD/Fs and DL-PCBs in animal feed [Commission Directive 2006/13/EC of 3 February 2006 amending Annexes I and II to Directive 2002/32/EC of the European Parliament and of the Council on undesirable substances in animal feed as regards dioxins and dioxin-like PCBs. Official Journal of the European Communities L32, 44-53]. In a second group, fats and oils with a more complex composition obtained from different transformation processes or even mixtures of fats were considered; thus, acid oils from chemical refining, acid oils from physical refining, recycled cooking oils, oils extracted from exhausted bleaching earths, hydrogenated by-products, fatty acids calcium soaps and miscellaneous fats were analyzed. The data revealed a significant variability in PCDD/F and DL-PCB levels, expressed in pg WHO-TEQ/g, in these products. It has to be pointed out that the analyses of fats and oils belonging to these categories of products were sometimes difficult due to the complexity of the samples. In terms of legislation most of these samples cannot be easily included into one of the specific categories of substances intended for feedstuff purposes that are regulated in Commission Directive 2006/13/EC.


Assuntos
Gorduras/química , Cadeia Alimentar , Bifenilos Policlorados/análise , Dibenzodioxinas Policloradas/análogos & derivados , Ração Animal/análise , Animais , Gorduras/metabolismo , Contaminação de Alimentos/análise , Cromatografia Gasosa-Espectrometria de Massas , Lecitinas/análise , Dibenzodioxinas Policloradas/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...