Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Diagnostics (Basel) ; 12(12)2022 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-36553193

RESUMO

The development of rapid, accurate, and efficient detection methods for Salmonella can significantly control the outbreak of salmonellosis that threatens global public health. Despite the high sensitivity and specificity of the microbiological, nucleic-acid, and immunological-based methods, they are impractical for detecting samples outside of the laboratory due to the requirement for skilled individuals and sophisticated bench-top equipment. Ideally, an electrochemical biosensor could overcome the limitations of these detection methods since it offers simplicity for the detection process, on-site quantitative analysis, rapid detection time, high sensitivity, and portability. The present scoping review aims to assess the current trends in electrochemical aptasensors to detect and quantify Salmonella. This review was conducted according to the latest Preferred Reporting Items for Systematic review and Meta-Analyses extension for Scoping Reviews (PRISMA-ScR) guidelines. A literature search was performed using aptamer and Salmonella keywords in three databases: PubMed, Scopus, and Springer. Studies on electrochemical aptasensors for detecting Salmonella published between January 2014 and January 2022 were retrieved. Of the 787 studies recorded in the search, 29 studies were screened for eligibility, and 15 studies that met the inclusion criteria were retrieved for this review. Information on the Salmonella serovars, targets, samples, sensor specification, platform technologies for fabrication, electrochemical detection methods, limit of detection (LoD), and detection time was discussed to evaluate the effectiveness and limitations of the developed electrochemical aptasensor platform for the detection of Salmonella. The reported electrochemical aptasensors were mainly developed to detect Salmonella enterica Typhimurium in chicken meat samples. Most of the developed electrochemical aptasensors were fabricated using conventional electrodes (13 studies) rather than screen-printed electrodes (SPEs) (two studies). The developed aptasensors showed LoD ranges from 550 CFU/mL to as low as 1 CFU/mL within 5 min to 240 min of detection time. The promising detection performance of the electrochemical aptasensor highlights its potential as an excellent alternative to the existing detection methods. Nonetheless, more research is required to determine the sensitivity and specificity of the electrochemical sensing platform for Salmonella detection, particularly in human clinical samples, to enable their future use in clinical practice.

2.
Micromachines (Basel) ; 13(1)2022 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-35056243

RESUMO

In this present work, we aim to improve the hydrophobicity of a polydimethylsiloxane (PDMS) surface. Various heights of 3D PDMS micropillars were fabricated via grayscale photolithography, and improved wettability was investigated. Two approaches of PDMS replication were demonstrated, both using a single master mold to obtain the micropillar arrays. The different heights of fabricated PDMS micropillars were characterized by scanning electron microscopy (SEM) and a surface profiler. The surface hydrophobicity was characterized by measuring the water contact angles. The fabrication of PDMS micropillar arrays was shown to be effective in modifying the contact angles of pure water droplets with the highest 157.3-degree water contact angle achieved by implementing a single mask grayscale lithography technique.

3.
Biosensors (Basel) ; 11(12)2021 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-34940235

RESUMO

Heavy metal pollution remains a major concern for the public today, in line with the growing population and global industrialization. Heavy metal ion (HMI) is a threat to human and environmental safety, even at low concentrations, thus rapid and continuous HMI monitoring is essential. Among the sensors available for HMI detection, the field-effect transistor (FET) sensor demonstrates promising potential for fast and real-time detection. The aim of this review is to provide a condensed overview of the contribution of certain semiconductor substrates in the development of chemical and biosensor FETs for HMI detection in the past decade. A brief introduction of the FET sensor along with its construction and configuration is presented in the first part of this review. Subsequently, the FET sensor deployment issue and FET intrinsic limitation screening effect are also discussed, and the solutions to overcome these shortcomings are summarized. Later, we summarize the strategies for HMIs' electrical detection, mechanisms, and sensing performance on nanomaterial semiconductor FET transducers, including silicon, carbon nanotubes, graphene, AlGaN/GaN, transition metal dichalcogenides (TMD), black phosphorus, organic and inorganic semiconductor. Finally, concerns and suggestions regarding detection in the real samples using FET sensors are highlighted in the conclusion.


Assuntos
Metais Pesados , Nanotubos de Carbono , Transistores Eletrônicos , Técnicas Biossensoriais , Íons , Metais Pesados/análise , Nanotecnologia
4.
Biosensors (Basel) ; 11(9)2021 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-34562936

RESUMO

Large-scale food-borne outbreaks caused by Salmonella are rarely seen nowadays, thanks to the advanced nature of the medical system. However, small, localised outbreaks in certain regions still exist and could possess a huge threat to the public health if eradication measure is not initiated. This review discusses the progress of Salmonella detection approaches covering their basic principles, characteristics, applications, and performances. Conventional Salmonella detection is usually performed using a culture-based method, which is time-consuming, labour intensive, and unsuitable for on-site testing and high-throughput analysis. To date, there are many detection methods with a unique detection system available for Salmonella detection utilising immunological-based techniques, molecular-based techniques, mass spectrometry, spectroscopy, optical phenotyping, and biosensor methods. The electrochemical biosensor has growing interest in Salmonella detection mainly due to its excellent sensitivity, rapidity, and portability. The use of a highly specific bioreceptor, such as aptamers, and the application of nanomaterials are contributing factors to these excellent characteristics. Furthermore, insight on the types of biorecognition elements, the principles of electrochemical transduction elements, and the miniaturisation potential of electrochemical biosensors are discussed.


Assuntos
Técnicas Eletroquímicas , Microbiologia de Alimentos , Salmonella , Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Limite de Detecção , Nanoestruturas
5.
Micromachines (Basel) ; 11(6)2020 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-32485795

RESUMO

Three-dimensional (3D) microstructures have been exploited in various applications of microfluidic devices. Multilevel structures in micromixers are among the essential structures in microfluidic devices that exploit 3D microstructures for different tasks. The efficiency of the micromixing process is thus crucial, as it affects the overall performance of a microfluidic device. Microstructures are currently fabricated by less effective techniques due to a slow point-to-point and layer-by-layer pattern exposure by using sophisticated and expensive equipment. In this work, a grayscale photolithography technique is proposed with the capability of simultaneous control on lateral and vertical dimensions of microstructures in a single mask implementation. Negative photoresist SU8 is used for mould realisation with structural height ranging from 163.8 to 1108.7 µm at grayscale concentration between 60% to 98%, depending on the UV exposure time. This technique is exploited in passive micromixers fabrication with multilevel structures to study the mixing performance. Based on optical absorbance analysis, it is observed that 3D serpentine structure gives the best mixing performance among other types of micromixers.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...