Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
Tomography ; 10(2): 255-265, 2024 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-38393288

RESUMO

This study investigated the efficacy of single-phase dual-energy CT (DECT) in differentiating pulmonary hamartomas from malignant lung lesions using virtual non-contrast (VNC), iodine, and fat quantification. Forty-six patients with 47 pulmonary lesions (mean age: 65.2 ± 12.1 years; hamartomas-to-malignant lesions = 22:25; male: 67%) underwent portal venous DECT using histology, PET-CT and follow-up CTs as a reference. Quantitative parameters such as VNC, fat fraction, iodine density and CT mixed values were statistically analyzed. Significant differences were found in fat fractions (hamartomas: 48.9%; malignancies: 22.9%; p ≤ 0.0001) and VNC HU values (hamartomas: -20.5 HU; malignancies: 17.8 HU; p ≤ 0.0001), with hamartomas having higher fat content and lower VNC HU values than malignancies. CT mixed values also differed significantly (p ≤ 0.0001), but iodine density showed no significant differences. ROC analysis favored the fat fraction (AUC = 96.4%; sensitivity: 100%) over the VNC, CT mixed value and iodine density for differentiation. The study concludes that the DECT-based fat fraction is superior to the single-energy CT in differentiating between incidental pulmonary hamartomas and malignant lesions, while post-contrast iodine density is ineffective for differentiation.


Assuntos
Hamartoma , Iodo , Neoplasias Pulmonares , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Hamartoma/diagnóstico por imagem
2.
CVIR Endovasc ; 7(1): 23, 2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38416319

RESUMO

BACKGROUND: The Viabahn stent graft has emerged as an integral tool for managing vascular diseases, but there is limited long-term data on its performance in emergency endovascular treatment. This study aimed to assess safety, technical success, and long-term efficacy of the Viabahn stent graft in emergency treatment of arterial injury. METHODS: We conducted a retrospective single tertiary centre analysis of patients who underwent Viabahn emergency arterial injury treatment between 2015 and 2020. Indication, intraoperative complications, technical and clinical success, and major adverse events at 30 days were evaluated. Secondary efficacy endpoints were the primary and secondary patency rates assessed by Kaplan-Meier analysis. RESULTS: Forty patients (71 ± 13 years, 19 women) were analyzed. Indications for Viabahn emergency treatment were extravasation (65.0%), arterio-venous fistula (22.5%), pseudoaneurysm (10.0%), and arterio-ureteral fistula (2.5%). No intraoperative adverse events occurred, technical and clinical success rates were 100%. One acute stent graft occlusion occurred in the popliteal artery on day 9, resulting in a 30-day device-related major-adverse-event rate of 2.5%. Median follow-up was 402 days [IQR, 43-1093]. Primary patency rate was 97% (95% CI: 94-100) in year 1, and 92% (95% CI: 86-98) from years 2 to 6. One stent graft occlusion occurred in the external iliac artery at 18 months; successful revascularization resulted in secondary patency rates of 97% (95% CI: 94-100) from years 1 to 6. CONCLUSION: Using Viabahn stent graft in emergency arterial injury treatment had 100% technical and clinical success rates, a low 30-day major-adverse-event rate of 2.5%, and excellent long-term patency rates.

3.
Rofo ; 196(3): 283-291, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37995733

RESUMO

PURPOSE: To provide an overview of endovascular treatment of renal artery stenosis (RAS) using the data of the Deutsche Gesellschaft für interventionelle Radiologie (DeGIR) quality management system. MATERIALS AND METHODS: A retrospective analysis was performed. Pre-, peri- and postprocedural data, technical success rates, complication rates, and clinical success rates at dismissal were examined. RESULTS: Between 2018 and 2021, 2134 angiography examinations of the renal arteries were performed: diagnostic angiography in 70 patients (3 %), balloon angioplasty in 795 (37 %), stent implantation in 1166 (55 %) and miscellaneous procedures in 103 (5 %). The lesion length was less than or equal to 5 mm in 1837 patients (87 %), between 5 and 10 mm in 197 (9 %), and between 10 and 20 mm in 62 (3 %). The degree of stenosis was less than 50 % in 156 patients (7 %), greater than 50 % in 239 (11 %), and greater than 70 % in 1472 (70 %). Occlusion was treated in 235 patients (11 %). Symptoms at discharge resolved in 600 patients (29 %), improved in 1012 (49 %), were unchanged in 77 (4 %), and worsened in 5 (0.2 %). Complications were reported in 51 patients (2.5 %) and the mortality rate was 0.15 %. CONCLUSION: A substantial number of patients with RAS and occlusions were treated by radiologists in Germany, with high technical success rates and low complication rates. The indication should be determined carefully as the current European guidelines for the treatment of RAS suggest that only carefully selected groups of patients will benefit from recanalizing treatment. KEY POINTS: · Carefully selected patient groups may benefit from endovascular treatment of renal artery stenosis.. · Analysis of the DEGIR quality management database shows that treatment of renal artery stenosis was performed by radiologists in Germany with high technical success rates and low complication rates.. · Recanalization even led to symptom improvement in a large proportion of patients with occlusions..


Assuntos
Angioplastia com Balão , Procedimentos Endovasculares , Obstrução da Artéria Renal , Humanos , Obstrução da Artéria Renal/diagnóstico por imagem , Obstrução da Artéria Renal/epidemiologia , Obstrução da Artéria Renal/terapia , Resultado do Tratamento , Estudos Retrospectivos , Angiografia , Stents
4.
Acad Radiol ; 2023 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-37989681

RESUMO

OBJECTIVES: In interventional bronchial artery embolization (BAE), periprocedural cone beam CT (CBCT) improves guiding and localization. However, a trade-off exists between 6-second runs (high radiation dose and motion artifacts, but low noise) and 3-second runs (vice versa). This study aimed to determine the efficacy of an advanced deep learning denoising (DLD) technique in mitigating the trade-offs related to radiation dose and image quality during interventional BAE CBCT. MATERIALS AND METHODS: This study included BMI-matched patients undergoing 6-second and 3-second BAE CBCT scans. The dose-area product values (DAP) were obtained. All datasets were reconstructed using standard weighted filtered back projection (OR) and a novel DLD software. Objective image metrics were derived from place-consistent regions of interest, including CT numbers of the Aorta and lung, noise, and contrast-to-noise ratio. Three blinded radiologists performed subjective assessments regarding image quality, sharpness, contrast, and motion artifacts on all dataset combinations in a forced-choice setup (-1 = inferior, 0 = equal; 1 = superior). The points were averaged per item for a total score. Statistical analysis ensued using a properly corrected mixed-effects model with post hoc pairwise comparisons. RESULTS: Sixty patients were assessed in 30 matched pairs (age 64 ± 15 years; 10 female). The mean DAP for the 6 s and 3 s runs was 2199 ± 185 µGym² and 1227 ± 90 µGym², respectively. Neither low-dose imaging nor the reconstruction method introduced a significant HU shift (p ≥ 0.127). The 3 s-DLD presented the least noise and superior contrast-to-noise ratio (CNR) (p < 0.001). While subjective evaluation revealed no noticeable distinction between 6 s-DLD and 3 s-DLD in terms of quality (p ≥ 0.996), both outperformed the OR variants (p < 0.001). The 3 s datasets exhibited fewer motion artifacts than the 6 s datasets (p < 0.001). CONCLUSIONS: DLD effectively mitigates the trade-off between radiation dose, image noise, and motion artifact burden in regular reconstructed BAE CBCT by enabling diagnostic scans with low radiation exposure and inherently low motion artifact burden at short examination times.

5.
Cancers (Basel) ; 15(20)2023 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-37894309

RESUMO

Even with liver-targeted therapies, uveal melanoma with hepatic metastasis remains a challenge. The aim of this study was to compare the outcome of patients treated with either SIRT or CS-PHP. We included 62 patients with hepatic metastasized uveal melanoma (n = 34 with SIRT, receiving 41 cycles; n = 28 with CS-PHP, receiving 56 cycles) that received their treatments between 12/2013 and 02/2020 at a single center. We evaluated their response according to the RECIST 1.1, as well as progression-free survival (PFS) and overall survival (OS), after the initiation of the first cycle of the liver-directed treatment using Cox regression, adjusted via propensity score analysis for confounders, including the amount of hepatic involvement. The disease control rate was 18% for SIRT and 30% for CS-PHP. The median (range) of PFS was 127.5 (19-1912) days for SIRT and 408.5 (3-1809) days for CS-PHP; adjusted Cox regression showed no significant difference (p = 0.090). The median (range) of OS was 300.5 (19-1912) days for SIRT and 516 (5-1836) days for CS-PHP; adjusted Cox regression showed a significant difference (p = 0.006). In our patient cohort, patients treated with CS-PHP showed a significantly longer OS than patients treated with SIRT. CS-PHP might therefore be preferable for patients with liver-dominant metastatic uveal melanoma.

6.
BMC Gastroenterol ; 23(1): 241, 2023 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-37460992

RESUMO

PURPOSE: To evaluate efficacy, safety, and outcomes of endovascular treatment of hepatic vein stenosis post major liver resection. METHODS: A retrospective data analysis was performed including all interventional treatments of hepatic vein stenosis post major liver resection since 2010. Post procedural course and clinical parameters including amount of ascites accumulation and relevant laboratory values were assessed during the follow-up period. Primary and primary assisted hepatic venous patency time were calculated. RESULTS: Twelve patients (median age 55.5, IQR 49.75 to 61.5 years) undergoing a total of 16 interventions were included. Interventions were primary stent placement (n = 3), primary balloon angioplasty (n = 8), three re-interventions and two aborted interventions (no significant pressure gradient). Technical success was 100% (16/16). Permanent reduction and / or complete resolution of ascites was achieved in 72% (8/11). Laboratory parameters related to liver function did not show significant improvement after intervention. Median follow-up period was 6 months (IQR: 1.5 to 18 months). The median primary patency time for patients with balloon angioplasty was 11 months (IQR: 1.375 to 22.25 months) and assisted patency time was 13.25 months (IQR: 4.5 to 22.25 months). The median primary patency time for patients with angioplasty and stent placement was 1 months (IQR: 1.0 to 1.5 months) and assisted patency time was 2.0 months (IQR: 1.5 to 2.5months). CONCLUSION: An endovascular approach for the treatment of hepatic venous stenosis post major liver resection is safe and efficient to reduce and / or resolve refractory ascites. However, liver function parameters seem not to be improved by the procedure. Stent placement can be a reasonable option in patients with significant residual stenotic disease post angioplasty.


Assuntos
Angioplastia com Balão , Síndrome de Budd-Chiari , Procedimentos Endovasculares , Transplante de Fígado , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Ascite/etiologia , Ascite/terapia , Constrição Patológica/etiologia , Constrição Patológica/cirurgia , Resultado do Tratamento , Angioplastia com Balão/métodos , Stents
8.
Pediatr Radiol ; 53(9): 1885-1893, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37147428

RESUMO

PURPOSE: To evaluate the safety and efficacy of percutaneous interventional treatment of portal vein stenosis in children. MATERIAL AND METHODS: A retrospective analysis of all interventional treatments for portal vein stenosis in pediatric patients at a single institution from 2010 to 2021 was conducted. Platelet count, spleen size and portal vein flow velocity were assessed during the follow-up period. Primary and primary assisted patency time were determined. RESULTS: A total of ten children (median age 28.5 months, interquartile range (IQR): 2.75-52.5 months) with portal vein stenosis after Mesorex-Shunt (n = 4), liver transplantation (n = 3) and other etiologies (n = 3) underwent 15 interventional procedures. There were five reinterventions and one discontinued intervention. The technical success rate was 93.3% (14/15) and clinical success of treated patients was 100% (14/14). Median follow-up was 18 months (IQR: 13.5-81 months). The median primary patency time for stent placement was 70 months (IQR: 13.5-127.25 months). For balloon angioplasty, the median primary patency time was 9 months (IQR 7.25-11.5 months), while the median assisted primary patency time was 14 months (IQR: 12 to 15 months). Platelet count, spleen size and portal vein flow velocity reliably corresponded to recurrence of portal vein stenosis in asymptomatic patients during follow-up. CONCLUSION: Interventional treatment is a safe and efficient method to treat portal vein stenosis with long patency times, regardless of etiology. Primary stent placement shows a higher primary patency time than balloon angioplasty. Implementation of stent placement as the primary interventional method may improve patency times and reduce the need for repeat reinterventions in pediatric patients.


Assuntos
Angioplastia com Balão , Veia Porta , Criança , Humanos , Pré-Escolar , Veia Porta/diagnóstico por imagem , Veia Porta/cirurgia , Resultado do Tratamento , Constrição Patológica/cirurgia , Estudos Retrospectivos , Angioplastia com Balão/efeitos adversos , Angioplastia com Balão/métodos , Stents
9.
Cardiovasc Diagn Ther ; 13(1): 133-146, 2023 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-36864951

RESUMO

Background and Objective: Vascular calcification (VC) and resulting vascular disease is one of the major causes of cardiovascular morbidity and mortality in patients with chronic kidney disease (CKD). CKD itself is increasingly recognized as a risk factor for cardiac and peripheral arterial disease (PAD). This paper examines the atherosclerotic plaque composition and specific endovascular considerations in the end stage renal disease (ESRD) patients. The literature was reviewed regarding the current status of medical and interventional management arteriosclerotic disease in patients with CKD. Lastly, three representative cases displaying typical endovascular treatment options are provided. Methods: A literature search was performed in PubMed covering publications up to September 2021 as well as discussion with experts in the field. Key Content and Findings: The high prevalence of atherosclerotic lesions in patients with chronic renal failure and high (re-)stenosis cause problems in the medium and long term as vascular calcium load represents one of the most widely encountered predictors of failure of endovascular treatment of PAD and future cardiovascular events (e.g., coronary calcium score). Patients with CKD also suffer from a greater risk for major vascular adverse events in general and worse revascularization outcomes following peripheral vascular intervention. A correlation between calcium burden and drug-coated balloon (DCB) performance has been established for PAD necessitating the need for different tools to cope with vascular calcium such as endoprosthesis or braided stents. Patients with CKD are at a higher risk of developing contrast-induced nephropathy (CIN). In addition to recommendations such as the administration of intravenous fluids, carbon dioxide (CO2) angiography is one option to potentially provide an effective and safe alternative both to iodine-based contrast media allergy and to the use of iodine-based contrast media in patients with CKD. Conclusions: Management and endovascular procedures of patients with ESRD are complex. In the course of time, new endovascular therapy methods have been developed such as directional atherectomy (DA) and the so-called "pave-and-crack" technique to deal with high vascular calcium burden. Besides interventional therapy, vascular patients with CKD benefit from aggressive medical management.

10.
Int J Cardiovasc Imaging ; 39(5): 1023-1030, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36781568

RESUMO

To evaluate Quiescent Interval Slice Selective (QISS) balanced steady-state free precession (bSSFP) and QISS fast low-angle shot (FLASH) sequences for non-contrast Magnetic Resonance Angiography (MRA) of iliac arteries regarding image quality and diagnostic confidence in order to establish these sequences in daily clinical practice. A prospective study of healthy subjects (n = 10) was performed. All subjects underwent the QISS MRI protocol with bSSFP und FLASH sequences. Vessel contrast-to-background ratio (VCBR) were measured in pre-defined vessel segments. Image quality and diagnostic confidence was assessed using a Likert scale (five-point scale). Inter-reader agreement was determined using Cohen's kappa coefficient (κ). Ten healthy subjects (median age 29 years, IQR: 26.25 to 30 years) were included in this prospective study. Median MR examination time was 2:05 min (IQR 1:58 to 2:16) for QISS bSSFP and 4:11 min (IQR 3:57 to 4:32) for QISS FLASH. Both sequences revealed good VCBR in all examined vessel segments. VCBR (muscle tissue) were marginally higher for FLASH sequences (e.g., 0.82 vs. 0.78 in the right femoral artery, p = 0.035*), while bSSFP sequence showed significantly higher VCBR (fat tissue) in the majority of examined arterials vessels (e.g., 0.78 vs. 0.62 in right femoral artery, p = 0.001*). The image quality and diagnostic confidence of both sequences were rated as good to excellent. Moderate to good inter-reader agreement was found. QISS MRA using bSSFP and FLASH sequences are diagnostic for visualization of iliac arterial vasculature. The QISS bSSFP sequence might offer advantages due to the markedly shorter exam time and superior visualization of smaller vessels. The QISS FLASH sequence seems to be a robust alternative for non-contrast MRA since it is less sensitive to magnetic field inhomogeneities.


Assuntos
Artérias , Angiografia por Ressonância Magnética , Humanos , Adulto , Estudos Prospectivos , Valor Preditivo dos Testes , Angiografia por Ressonância Magnética/métodos , Reprodutibilidade dos Testes , Meios de Contraste
11.
Rofo ; 195(5): 406-415, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36261069

RESUMO

PURPOSE: To evaluate the safety and efficacy of rotational thrombectomy (RT) in a large single-center real-world cohort for total vascular occlusions of the lower extremity. MATERIALS AND METHODS: The clinical records and images of all patients between 2010 and 2020 treated via RT (Rotarex, BD) were assessed. Patient demographics, clinical data, procedural characteristics, and outcome parameters were documented. In total, 397 procedures in 293 patients were included (mean age 69.8 ±â€Š12.0 years; 64.8 % male). Occlusions were acute (47.5 %), subacute and acute-on-chronic (22.2 %), and chronic (30.3 %). The target lesions were the iliac artery (7.1 %), iliac/femoropopliteal (5.0 %), femoropopliteal (59.4 %), femoropopliteal/below-the-knee (27.0 %), below-the-knee (1.5 %), and after bypass surgery (14.9 %). Lesion length was > 20 cm in 61.5 % of cases. RESULTS: Clinically successful revascularization was achieved in 90.4 % of cases. Additional thrombolysis was necessary for 32.0 % of procedures. The arithmetic mean ankle-brachial index increased from 0.33 ±â€Š0.29 to 0.81 ±â€Š0.25 (p < 0.0001). Bypass grafts were less likely to be fully treatable and required additional lysis (p < 0.001). The overall primary patency (no clinically driven target lesion revascularization) was 93.2 %, 88.8 %, 79.1 %, and 72.4 % at 1, 3, 6, and 12 months, respectively. Adverse events occurred in 46.1 % of cases, of which peripheral embolization (22.4 %) was most frequent, requiring interventional treatment in 67.4 % of cases. RT was directly associated with 7.1 % (n = 28) of complications, which consisted of perforations 2.8 %, arteriovenous fistula 1.3 %, and dissections 2.0 %. CONCLUSION: Rotational thrombectomy is a safe and efficient method for the treatment of occlusions of the arterial circulation of the lower extremity with bypass occlusions having a higher propensity for residual thrombi requiring further lysis therapy. KEY POINTS: · Rotational thrombectomy was safe and efficacious for treating occlusions of the lower extremities.. · Rotational thrombectomy was associated with 7.1 % of complications.. · Distal embolization occurred in 22.4 % of cases with 67.4 % requiring interventional treatment.. · Primary patency was 93.2 %, 88.8 %, 79.1 %, 72.4 % after 1, 3, 6, and 12 months, respectively.. CITATION FORMAT: · Artzner C, Martin I, Hefferman G et al. Safety and Efficacy of Rotational Thrombectomy for Treatment of Arterial Occlusions of the Lower Extremities: A Large Single-Center Retrospective Study. Fortschr Röntgenstr 2023; 195: 406 - 415.


Assuntos
Arteriopatias Oclusivas , Artéria Poplítea , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Feminino , Estudos Retrospectivos , Artéria Poplítea/cirurgia , Trombectomia/métodos , Artéria Femoral/cirurgia , Arteriopatias Oclusivas/terapia , Arteriopatias Oclusivas/cirurgia , Extremidade Inferior , Resultado do Tratamento , Grau de Desobstrução Vascular
12.
J Endovasc Ther ; 30(2): 185-193, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-35209760

RESUMO

PURPOSE: The objective of this study was to compare the outcomes of patients treated with tube grafts and AFX stent-graft in the narrow infrarenal aortic anatomy. MATERIALS AND METHODS: Patients with penetrating aortic ulcers (PAUs) or sacciform aneurysms of the infrarenal aorta and an aortic bifurcation diameter ≤20 mm who underwent endovascular aneurysm repair (EVAR) with bifurcated AFX or tube stent-grafts (TUBE) between 2012 and 2020 were included. Demographic data and the outcome of the AFX group were compared with the TUBE group. All morphological measurements in the preoperative and postoperative computed tomography scans were performed in the aortic centerline. RESULTS: Fifty-one patients (female: 12/51; 29%; median age: 72 years [63, 77]) with a median follow-up of 10 (3, 39) months, were included, of whom 35/51 (69%) had PAUs and 11/51 were symptomatic (22%). The aortic bifurcation diameter was 17 mm (15, 18) with severe calcifications in 25/51 (49%). The distal aortic landing zone was longer in the TUBE group (9 mm vs 24 mm; p<0.001). The technical success was 96% with a median aneurysm shrinkage of 8% (3, 13), which was comparable between the groups (p=0.264). Periprocedural mortality, conversion to open surgery, myocardial infarction, and stroke were not observed. Two type Ia endoleaks (EL) and 2 type Ib EL occurred, all in the TUBE group (Type 1 EL; 19 vs 0%; p=0.013). The limb patency in the AFX group was 100%. One patient with a tube graft developed an infrarenal aortic thrombosis 40 months after the intervention. The reintervention rate in the TUBE group was higher (14 vs 0%; p=0.032) and included 3 aortic cuff implantations and 1 covered endovascular aortic reconstruction of aortic bifurcation (CERAB). CONCLUSION: AFX stent-graft showed a lower rate of type I endoleaks and reinterventions in sacciform infrarenal aortic pathologies during the early and midterm follow-up.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Feminino , Idoso , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Correção Endovascular de Aneurisma , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Endoleak/cirurgia , Stents/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Estudos Retrospectivos , Prótese Vascular , Aorta Abdominal/cirurgia , Desenho de Prótese
13.
Eur J Cardiothorac Surg ; 63(1)2022 12 02.
Artigo em Inglês | MEDLINE | ID: mdl-36477549

RESUMO

OBJECTIVES: The aim of this study was to assess the endograft position and aortic geometry changes after thoracic endovascular aortic repair (TEVAR) and frozen elephant trunk (FET) in distal stent-induced new entry (dSINE) patients. METHODS: In this retrospective cohort study, the baseline demographic and the follow-up data were extracted from the hospital records, and computed tomography scans of dSINE patients after TEVAR or FET between 2011 and 2021 were analysed regarding endograft oversizing, length and migration, taper ratio, aortic diameter at the endograft end, aortic elongation (thoracic inner and outer curvature), wedge apposition angle and tortuosity angle in the distal landing zone. RESULTS: dSINE was found in 22/213 (10%) of TEVAR and 10/31 (32%) of FET patients. The total follow-up time was 45 (27; 59) months. TEVAR was mainly performed with Relay NBS endograft (77%) and FET with Evita open prosthesis (80%). Paraplegia and stroke rates were 3%. dSINE occurred 17 (7; 35) months post-TEVAR and was instantly treated in 18 patients (56%) or followed up for 21 (11; 34) months (n = 14). Migration [+5 mm (1; 11; P < 0.001)], birdbeak angle [+9° (0; 27; P = 0.039)] and aortic diameter +5 mm (1; 11; P < 0.001) increased after dSINE, whereas aortic elongation increased already before [+12 mm (0; 27; P = 0.015)] and peaked after dSINE [+30 mm (9; 38; P < 0.001)]. The aortic elongation was more pronounced in the outer aortic curvature before and after dSINE (before: P = 0.039, after: P = 0.024). Postoperative wedge apposition [17° (12; 20)] increased before dSINE [21° (16; 35; P < 0.001)] and peaked thereafter [31° (21; 40; P < 0.001)]. CONCLUSIONS: Aortic elongation may influence the endograft position and provoke TEVAR failure in the distal and proximal landing zones.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Stents/efeitos adversos , Dissecção Aórtica/cirurgia , Aorta/cirurgia , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/etiologia , Desenho de Prótese
14.
Diagnostics (Basel) ; 12(10)2022 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-36292231

RESUMO

The purpose of this study was to evaluate the potential of dual-energy CT (DECT) with virtual unenhanced imaging (VNC) and iodine maps (IM) to differentiate between intraperitoneal hematomas (IH) and bowel structures (BS) compared to linearly blended DECT (DE-LB) images (equivalent to single-energy CT). This retrospective study included the DECT of 30 patients (mean age: 64.5 ± 15.1 years, 19 men) with intraperitoneal hematomas and 30 negative controls. VNC, IM, and DE-LB were calculated. Imaging follow-up and surgical reports were used as references. Three readers assessed diagnostic performance and confidence in distinguishing IH and BS for DE-LB, VNC, and IM. Diagnostic confidence was assessed on a five-point Likert scale. The mean values of VNC, IM, and DE-LB were compared with nonparametric tests. Diagnostic accuracy was assessed by calculating receiver operating characteristics (ROC). The results are reported as medians with interquartile ranges. Subjective image analysis showed higher diagnostic performance (sensitivity: 96.7−100% vs. 88.2−96.7%; specificity: 100% vs. 96.7−100%; p < 0.0001; ICC: 0.96−0.99) and confidence (Likert: 5; IRQ [5−5] vs. 4, IRQ [3−4; 4−5]; p < 0.0001; ICC: 0.80−0.96) for DECT compared to DE-LB. On objective image analysis, IM values for DECT showed significant differences between IH (3.9 HU; IQR [1.6, 8.0]) and BS (39.5 HU; IQR [29.2, 43.3]; p ≤ 0.0001). VNC analysis revealed a significantly higher attenuation of hematomas (50.5 HU; IQR [44.4, 59.4]) than BS (26.6 HU; IQR [22.8, 32.4]; p ≤ 0.0001). DE-LB revealed no significant differences between hematomas (60.5 HU, IQR [52.7, 63.9]) and BS (63.9 HU, IQR [58.0, 68.8]; p > 0.05). ROC analysis revealed the highest AUC values and sensitivity for IM (AUC = 100%; threshold by Youden-Index ≤ 19 HU) and VNC (0.93; ≥34.1 HU) compared to DE-LB (0.64; ≤63.8; p < 0.001). DECT is suitable for accurate discrimination between IH and BS by calculating iodine maps and VNC images.

15.
Diagn Interv Radiol ; 28(4): 364-369, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35950281

RESUMO

PURPOSE The purpose of this study is to systematically evaluate the effect of tube voltage, current kernels, and monoenergetic post-processing on stent visualization. METHODS A 6 mm chrome-cobalt peripheral stent was placed in a dedicated phantom and scanned with the available tube voltage settings of a third-generation dual-source scanner in single-energy (SE) and dual-energy (DE) mode. Images were reconstructed using the latest convolution kernels and monoenergetic reconstructions (40-190 keV) for DE. The sharpness of stent struts (S), struts width (SW), contrast-to-noise-ratios (CNR), and pseudoenhancement (PE) between the vessel with and without stent were analyzed using an in-house built automatic analysis tool. Measurements were standardized through calculated z-scores. Z-scores were combined for stent (SQ), luminal (LQ), and overall depiction quality (OQ) by adding S and SW, CNR and SW and PE, and S and SW and CNR and PE. Two readers rated overall stent depiction on a 5-point Likert-scale. Agreement was calculated using linear-weighted kappa. Correlations were calculated using Spearman correlation coefficient. RESULTS Maximum values of S and CNR were 169.1 HU/pixel for [DE; 100/ Sn 150 kV; Qr59; 40 keV] and 50.0 for [SE; 70 kV; Bv36]. Minimum values of SW and PE were 2.615 mm for [DE; 80 to 90/ Sn 150 kV; Qr59; 140 to 190 keV] and 0.12 HU for [DE; 80/ Sn 150 kV; Qr36; 190 keV]. Best combined z-scores of SQ, LQ, and OQ were 4.53 for [DE; 100/ Sn 150 kV; Qr 59; 40 keV], 1.23 for [DE; 100/ Sn 150 kV; Qr59; 140 keV] and 2.95 for [DE; 90/ Sn 150 kV; Qr59; 50 keV]. Best OQ of SE was ranked third with 2.89 for [SE; 90 kV; Bv59]. Subjective agreement was excellent (kappa=0.86; P < .001) and correlated well with OQ (rs=0.94, P < .001). CONCLUSION Combining DE computed tomography (CT) acquisition with the latest kernels and monoenergetic post-processing allows for improved stent visualization as compared with SECT. The best overall results were obtained for monoenergetic reconstructions with 50 keV from DECT 90/Sn 150 kV acquisitions using kernel Qr59.


Assuntos
Algoritmos , Tomografia Computadorizada por Raios X , Humanos , Imagens de Fantasmas , Estudos Retrospectivos , Razão Sinal-Ruído , Stents , Tomografia Computadorizada por Raios X/métodos
16.
Diagnostics (Basel) ; 12(8)2022 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-35892500

RESUMO

The aim was to evaluate the accuracy of a prototypical artificial intelligence-based algorithm for automated segmentation and diameter measurement of the thoracic aorta (TA) using CT. One hundred twenty-two patients who underwent dual-source CT were retrospectively included. Ninety-three of these patients had been administered intravenous iodinated contrast. Images were evaluated using the prototypical algorithm, which segments the TA and determines the corresponding diameters at predefined anatomical locations based on the American Heart Association guidelines. The reference standard was established by two radiologists individually in a blinded, randomized fashion. Equivalency was tested and inter-reader agreement was assessed using intra-class correlation (ICC). In total, 99.2% of the parameters measured by the prototype were assessable. In nine patients, the prototype failed to determine one diameter along the vessel. Measurements along the TA did not differ between the algorithm and readers (p > 0.05), establishing equivalence. Inter-reader agreement between the algorithm and readers (ICC ≥ 0.961; 95% CI: 0.940−0.974), and between the readers was excellent (ICC ≥ 0.879; 95% CI: 0.818−0.92). The evaluated prototypical AI-based algorithm accurately measured TA diameters at each region of interest independent of the use of either contrast utilization or pathology. This indicates that the prototypical algorithm has substantial potential as a valuable tool in the rapid clinical evaluation of aortic pathology.

17.
Diagn Interv Radiol ; 28(3): 208-216, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35748202

RESUMO

PURPOSE Differentiation of incidental adrenal lesions remains a challenge in diagnostic imaging, especially on single-phase portal venous computed tomography (CT) in the oncological setting. The aim of the study was to explore the ability of dual-energy CT (DECT)-based iodine quantification and virtual non-contrast (VNC) imaging and advanced radiomic analysis of DECT for differentiation of adrenal adenomas from metastases. METHODS A total of 46 patients with 49 adrenal lesions underwent clinically indicated staging DECT and magnetic resonance imaging. Median values of quantitative parameters such as VNC, fat frac- tion, and iodine density in DECT images were collected and compared between adenomas and metastases using non-parametric tests. Magnetic resonance imaging, washout CT, and clinical follow-up were used as a reference standard. Diagnostic accuracy was assessed by calculat- ing receiver operating characteristics. A DECT tumor analysis prototype software was used for semiautomatic segmentation of adrenal lesions and extraction of radiomic features. A radiomics prototype was used to analyze the data with multiple logistic regression and random forest clas- sification to determine the area under the curve (AUC). RESULTS The study cohort (60.87% women; mean age: 66.91 ± 12.93 years) consisted of 32 adenomas and 17 metastases. DECT-based VNC imaging (AUC=0.89) and fat quantification (AUC=0.86) differentiate between adrenal adenomas and metastases with high diagnostic accuracy (P < .001). Analysis of radiomic features revealed that DECT features such as VNC imaging and fat fraction (AUC = 0.87-0.89; < .001) and radiomic features such as 90th percentile and total energy (AUC = 0.88-0.93; P < .001) differentiate with high diagnostic accuracy between adrenal adeno- mas and metastases. Random forest classification revealed an AUC of 0.83 for separating adrenal adenomas from metastases. CONCLUSION Virtual non-contrast imaging and fat quantification as well as extraction of radiomic features accurately differentiate between adrenal adenomas and metastases on single-phase oncologic staging DECT.


Assuntos
Adenoma , Neoplasias das Glândulas Suprarrenais , Iodo , Adenoma/diagnóstico por imagem , Adenoma/patologia , Neoplasias das Glândulas Suprarrenais/diagnóstico por imagem , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
18.
Tomography ; 8(2): 933-947, 2022 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-35448709

RESUMO

(1) To investigate whether interventional cone-beam computed tomography (cbCT) could benefit from AI denoising, particularly with respect to patient body mass index (BMI); (2) From 1 January 2016 to 1 January 2022, 100 patients with liver-directed interventions and peri-procedural cbCT were included. The unenhanced mask run and the contrast-enhanced fill run of the cbCT were reconstructed using weighted filtered back projection. Additionally, each dataset was post-processed using a novel denoising software solution. Place-consistent regions of interest measured signal-to-noise ratio (SNR) per dataset. Corrected mixed-effects analysis with BMI subgroup analyses compared objective image quality. Multiple linear regression measured the contribution of "Radiation Dose", "Body-Mass-Index", and "Mode" to SNR. Two radiologists independently rated diagnostic confidence. Inter-rater agreement was measured using Spearman correlation (r); (3) SNR was significantly higher in the denoised datasets than in the regular datasets (p < 0.001). Furthermore, BMI subgroup analysis showed significant SNR deteriorations in the regular datasets for higher patient BMI (p < 0.001), but stable results for denoising (p > 0.999). In regression, only denoising contributed positively towards SNR (0.6191; 95%CI 0.6096 to 0.6286; p < 0.001). The denoised datasets received overall significantly higher diagnostic confidence grades (p = 0.010), with good inter-rater agreement (r ≥ 0.795, p < 0.001). In a subgroup analysis, diagnostic confidence deteriorated significantly for higher patient BMI (p < 0.001) in the regular datasets but was stable in the denoised datasets (p ≥ 0.103).; (4) AI denoising can significantly enhance image quality in interventional cone-beam CT and effectively mitigate diagnostic confidence deterioration for rising patient BMI.


Assuntos
Inteligência Artificial , Tomografia Computadorizada de Feixe Cônico , Tomografia Computadorizada de Feixe Cônico/métodos , Humanos , Razão Sinal-Ruído
19.
Rofo ; 194(9): 1012-1019, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35272363

RESUMO

PURPOSE: To investigate reduction of radiation exposure in unenhanced CT in suspicion of renal calculi using a tin-filtered high tube voltage protocol compared to a standard low-dose protocol without spectral shaping. MATERIALS AND METHODS: A phantom study using 7 human renal calculi was performed to test both protocols. 120 consecutive unenhanced CT examinations performed due to suspicion of renal calculi were included in this retrospective, monocentric study. 60 examinations were included with the standard-dose protocol (SP) (100 kV/130 mAs), whereas another 60 studies were included using a low-dose protocol (LD) applying spectral shaping with tin filtration of high tube voltages (Sn150 kV/80 mAs). Image quality was assessed by two radiologists in consensus blinded to technical parameters using an equidistant Likert scale ranging from 1-5 with 5 being the highest score. Quantitative image quality was assessed using regions of interest in abdominal organs, muscles, and adipose tissue to analyze image noise and signal-to-noise ratios (SNR). Commercially available dosimetry software was used to determine and compare effective dose (ED) and size-specific dose estimates (SSDEmean). RESULTS: All seven renal calculi of the phantom could be detected with both protocols. There was no difference regarding calcluli size between the two protocols except for the smallest one. The smallest concretion measured 1.5 mm in LD and 1.0 mm in SP (ground truth 1.5 mm). CTDIvol was 3.36 mGy in LD (DLP: 119.3 mGycm) and 8.27 mGy in SP (DLP: 293.6 mGycm). The mean patient age in SP was 47 ±â€Š17 years and in LD 49 ±â€Š13 years. Ureterolithiasis was found in 33 cases in SP and 32 cases in LD. The median concretion size was 3 mm in SP and 4 mm in LD. The median ED in LD was 1.3 mSv (interquartile range (IQR) 0.3 mSv) compared to 2.3 mSv (IQR 0.9 mSv) in SP (p < 0.001). The SSDEmean of LD was also significantly lower compared to SP with 2.4 mGy (IQR 0.4 mGy) vs. 4.8 mGy (IQR 2.3 mGy) (p < 0.001). The SNR was significantly lower in LD compared to SP (p < 0.001). However, there was no significant difference between SP and LD regarding the qualitative assessment of image quality with a median of 4 (IQR 1) for both groups (p = 0.648). CONCLUSION: Tin-filtered unenhanced abdominal CT for the detection of renal calculi using high tube voltages leads to a significant reduction of radiation exposure and yields high diagnostic image quality without a significant difference compared to the institution's standard of care low-dose protocol without tin filtration. KEY POINTS: · Tin-filtered CT for the detection of renal calculi significantly reduces radiation dose.. · The application of tin filtration provides comparable diagnostic image quality to that of SP protocols.. · An increase in image noise does not hamper diagnostic image quality.. CITATION FORMAT: · Gassenmaier S, Winkelmann MT, Magnus J et al. Low-Dose CT for Renal Calculi Detection Using Spectral Shaping of High Tube Voltage. Fortschr Röntgenstr 2022; 194: 1012 - 1019.


Assuntos
Cálculos Renais , Tomografia Computadorizada por Raios X , Adulto , Humanos , Pessoa de Meia-Idade , Doses de Radiação , Estudos Retrospectivos , Estanho
20.
Diagnostics (Basel) ; 12(1)2022 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-35054391

RESUMO

(1) Background: To evaluate the effects of an AI-based denoising post-processing software solution in low-dose whole-body computer tomography (WBCT) stagings; (2) Methods: From 1 January 2019 to 1 January 2021, we retrospectively included biometrically matching melanoma patients with clinically indicated WBCT staging from two scanners. The scans were reconstructed using weighted filtered back-projection (wFBP) and Advanced Modeled Iterative Reconstruction strength 2 (ADMIRE 2) at 100% and simulated 50%, 40%, and 30% radiation doses. Each dataset was post-processed using a novel denoising software solution. Five blinded radiologists independently scored subjective image quality twice with 6 weeks between readings. Inter-rater agreement and intra-rater reliability were determined with an intraclass correlation coefficient (ICC). An adequately corrected mixed-effects analysis was used to compare objective and subjective image quality. Multiple linear regression measured the contribution of "Radiation Dose", "Scanner", "Mode", "Rater", and "Timepoint" to image quality. Consistent regions of interest (ROI) measured noise for objective image quality; (3) Results: With good-excellent inter-rater agreement and intra-rater reliability (Timepoint 1: ICC ≥ 0.82, 95% CI 0.74-0.88; Timepoint 2: ICC ≥ 0.86, 95% CI 0.80-0.91; Timepoint 1 vs. 2: ICC ≥ 0.84, 95% CI 0.78-0.90; all p ≤ 0.001), subjective image quality deteriorated significantly below 100% for wFBP and ADMIRE 2 but remained good-excellent for the post-processed images, regardless of input (p ≤ 0.002). In regression analysis, significant increases in subjective image quality were only observed for higher radiation doses (≥0.78, 95%CI 0.63-0.93; p < 0.001), as well as for the post-processed images (≥2.88, 95%CI 2.72-3.03, p < 0.001). All post-processed images had significantly lower image noise than their standard counterparts (p < 0.001), with no differences between the post-processed images themselves. (4) Conclusions: The investigated AI post-processing software solution produces diagnostic images as low as 30% of the initial radiation dose (3.13 ± 0.75 mSv), regardless of scanner type or reconstruction method. Therefore, it might help limit patient radiation exposure, especially in the setting of repeated whole-body staging examinations.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...