Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 13(1): 19314, 2023 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-37935831

RESUMO

Gas sensing is a critical research area in aerospace, military, medical, and industrial environments, as it helps prevent risks to human health and the environment caused by toxic gases. Propane and butane, commonly used as fuels in household and industrial settings, are toxic and flammable gases that need to be effectively detected to avoid leakage or explosion accidents. To address this, nanomaterial-based gas sensors are being developed with low power consumption and operating temperatures. In this study, two-dimensional nitrogenated holey graphene (C2N) based sensors are used for the first time for the identification of butane and propane gases. The sensor consists of two C2N electrodes connected via a C2N channel. The C2N sensor design was enhanced by replacing the C2N electrodes with gold electrodes and adding a gate terminal under the channel. The resistive method is employed to detect butane and propane gases by measuring the variation in the electrical conductivity of the sensor due to exposure to these target molecules. To investigate the electronic transport properties, such as transmission spectra, density of states and current, first principles simulations of the C2N-based sensors is conducted using Quantumwise Atomistix Toolkit (ATK). The detection method relies on the alteration of the FET's electrical current at specific gate voltages due to the presence of these gases. This proposed sensor offers the potential for small size and low-cost gas sensing applications. The designed sensor aims to effectively detect propane and butane gases. By leveraging the unique properties of C2N and utilizing advanced simulation tools, this sensor could provide high sensitivity and accuracy in detecting propane and butane gases. Such an advancement in gas sensing technology holds significant promise for ensuring safety in various environments.

2.
Sci Rep ; 13(1): 11415, 2023 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-37452048

RESUMO

The incubation of strained nano-system in the form of tri-layered structure as nanowire channel in the cylindrical-gate-all-around (CGAA) FET at 10 nm gate length is developed for the first time to keep abreast with the proposed 3 nm technology node of IRDS 2022. The system installs Type-II hetero-strain alignment in the channel attesting itself as the fastest operating device debasing the SCEs at nano regime. The ultra-thin strained-channel comprises of two cylindrical s-Si wells encompassing s-SiGe barrier in between, which enables improvement of carrier mobility by succumbing of quantum charge carriers in the region. This results in 2D charge centroid creation with cylindrical based circular Nano-system contemplating electrostatic potential difference leading to enriched electric field, current density and transconductance, while the gate-all-around architecture with increased gate controllability lowers leakage current, in the device. The 10 nm strained-channel CGAA astounded havoc ON current enhancements of ~ 20% over 22 nm strained CGAA, 57% over Si CGAA FET and 75% over proposed 3 nm technology node IRDS 2022 are accomplished. Hence, carrier mobility and velocity enriches instituting quasi-ballistic transport through the Nanowire channel, thereby augments in ~ 28% drain current so the 10 nm channel CGAA FET stands as the most suitable and improved device in nano regime.


Assuntos
Nanofios , Academias e Institutos , Eletricidade , Excipientes , Jejum
3.
Nanomaterials (Basel) ; 13(10)2023 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-37242078

RESUMO

Multi-gate field effect transistors (FETs) such as FinFETs are severely affected by short-channel effects (SCEs) below 14 nm technology nodes, with even taller fins incurring fringing capacitances. This leads to performance degradation of the devices, which inhibits further scaling of nanoFETs, deterring the progress of semiconductor industries. Therefore, research has not kept pace with the technological requirements of the International Roadmap for Devices and Systems (IRDS). Thus, the development of newer devices with superior performances in terms of higher ON currents, acceptable leakage currents and improved SCEs is needed to enable the continuance of integrated circuit (IC) technologies. The literature has advocated integration of strained-silicon technology in existing FinFETs, which is highly effective in enhancing ON currents through the strain effect. However, the ON currents can also be amplified by intensifying the number of fins in trigate (TG) FinFETs. Thus, three-fin TG quantum (Q)-FinFETs, using a novel tri-layered strained-silicon channel, are deployed here at 10 nm and 8 nm channel lengths. Threshold voltage is calculated analytically to validate the designs. The electrical parameters and quantum effects of both devices are explored, analysed and compared with respect to existing heterostructure-on-insulator (HOI) FinFETs and the proposed existing standard requirement of IRDS 2022 for a 3 nm technology node. The comparisons demonstrated a significant increase in the drive currents upon employing three fins of the same dimensions (8 nm gate length) and specifications in a device-based system. The performance is augmented in contrast to the 3 nm technology node device of IRDS 2022, with SCEs within the limits. Thus, employing a tri-layered strained-silicon channel system in each fin allowed for forming a three-fin Q-FinFET that, in our opinion, is the technique for consolidating the performance of the devices and enabling future generation device for faster switching operation in a sub-nano regime.

4.
Sensors (Basel) ; 23(6)2023 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-36991722

RESUMO

Graphene has remarkable characteristics that make it a potential candidate for optoelectronics and electronics applications. Graphene is a sensitive material that reacts to any physical variation in its environment. Due to its extremely low intrinsic electrical noise, graphene can detect even a single molecule in its proximity. This feature makes graphene a potential candidate for identifying a wide range of organic and inorganic compounds. Graphene and its derivatives are considered one of the best materials to detect sugar molecules due to their electronic properties. Graphene has low intrinsic noise, making it an ideal membrane for detecting low concentrations of sugar molecules. In this work, a graphene nanoribbon field effect transistor (GNR-FET) is designed and utilized to identify sugar molecules such as fructose, xylose, and glucose. The variation in the current of the GNR-FET in the presence of each of the sugar molecules is utilized as the detection signal. The designed GNR-FET shows a clear change in the device density of states, transmission spectrum, and current in the presence of each of the sugar molecules. The simulated sensor is made of a pair of metallic zigzag graphene nanoribbons (ZGNR) joint via a channel of armchair graphene nanoribbon (AGNR) and a gate. The Quantumwise Atomistix Toolkit (ATK) is used to design and conduct the nanoscale simulations of the GNR-FET. Semi-empirical modeling, along with non-equilibrium Green's functional theory (SE + NEGF), is used to develop and study the designed sensor. This article suggests that the designed GNR transistor has the potential to identify each of the sugar molecules in real time with high accuracy.

5.
Sci Rep ; 13(1): 4485, 2023 03 18.
Artigo em Inglês | MEDLINE | ID: mdl-36934198

RESUMO

Graphene field effect transistor (FET) biosensors have attracted huge attention in the point-of-care and accurate detection. With the recent spread of the new emerging severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the need for rapid, and accurate detection & screening tools is arising. Employing these easy-to-handle sensors can offer cheap, rapid, and accurate detection. Herein, we propose the design of a reduced graphene oxide (rGO) FET biosensor for the detection of SARS-CoV-2. The main objective of this work is to detect the SARS-CoV-2 spike protein antigen on spot selectively and rapidly. The sensor consists of rGO channel, a pair of golden electrodes, and a gate underneath the channel. The channel is functionalized with COVID-19 spike protein antibodies to achieve selectivity, and with metal nanoparticles (MNPs) such as copper and silver to enhance the bio-sensing performance. The designed sensor successfully detects the SARS-CoV-2 spike protein and shows singular electrical behavior for detection. The semi-empirical modeling approach combined with none-equilibrium Green's function were used to study the electronic transport properties of the rGO-FET biosensor before and after the addition of the target molecules. The sensor's selectivity is also tested against other viruses. This study provides a promising guide for future practical fabrication.


Assuntos
Técnicas Biossensoriais , COVID-19 , Humanos , COVID-19/diagnóstico , SARS-CoV-2 , Sistemas Automatizados de Assistência Junto ao Leito
6.
Nanomaterials (Basel) ; 13(4)2023 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-36839068

RESUMO

Real-time detection of sugar molecules is critical for preventing and monitoring diabetes and for food quality evaluation. In this article, a field effect transistor (FET) based on two-dimensional nitrogenated holey graphene (C2N) was designed, developed, and tested to identify the sugar molecules including xylose, fructose, and glucose. Both density functional theory and non-equilibrium Green's function (DFT + NEGF) were used to study the designed device. Several electronic characteristics were studied, including work function, density of states, electrical current, and transmission spectrum. The proposed sensor is made of a pair of gold electrodes joint through a channel of C2N and a gate was placed underneath the channel. The C2N monolayer distinctive characteristics are promising for glucose sensors to detect blood sugar and for sugar molecules sensors to evaluate food quality. The electronic transport characteristics of the sensor resulted in a unique signature for each of the sugar molecules. This proposed work suggests that the developed C2N transistor-based sensor could detect sugar molecules with high accuracy.

7.
Sci Rep ; 12(1): 18155, 2022 10 28.
Artigo em Inglês | MEDLINE | ID: mdl-36307495

RESUMO

Coronavirus 2019 (COVID-19) spreads an extremely infectious disease where there is no specific treatment. COVID-19 virus had a rapid and unexpected spread rate which resulted in critical difficulties for public health and unprecedented daily life disruption. Thus, accurate, rapid, and early diagnosis of COVID-19 virus is critical to maintain public health safety. A graphite oxide-based field-effect transistor (GO-FET) was fabricated and functionalized with COVID-19 antibody for the purpose of real-time detection of COVID-19 spike protein antigen. Thermal evaporation process was used to deposit the gold electrodes on the surface of the sensor substrate. Graphite oxide channel was placed between the gold electrodes. Bimetallic nanoparticles of platinum and palladium were generated via an ultra-high vacuum (UHV) compatible system by sputtering and inert-gas condensation technique. The biosensor graphite oxide channel was immobilized with specific antibodies against the COVID-19 spike protein to achieve selectivity and specificity. This technique uses the attractive semiconductor characteristics of the graphite oxide-based materials resulting in highly specific and sensitive detection of COVID-19 spike protein. The GO-FET biosensor was decorated with bimetallic nanoparticles of platinum and palladium to investigate the improvement in the sensor sensitivity. The in-house developed biosensor limit of detection (LOD) is 1 fg/mL of COVID-19 spike antigen in phosphate-buffered saline (PBS). Moreover, magnetic labelled SARS-CoV-2 spike antibody were studied to investigate any enhancement in the sensor performance. The results indicate the successful fabrication of a promising field effect transistor biosensor for COVID-19 diagnosis.


Assuntos
Técnicas Biossensoriais , COVID-19 , Grafite , Nanopartículas , Humanos , Óxidos , Platina , Transistores Eletrônicos , Paládio , Teste para COVID-19 , COVID-19/diagnóstico , Glicoproteína da Espícula de Coronavírus , SARS-CoV-2 , Técnicas Biossensoriais/métodos , Ouro
8.
Nanomaterials (Basel) ; 12(15)2022 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-35957069

RESUMO

Biomolecular detection methods have evolved from simple chemical processes to laboratory sensors capable of acquiring accurate measurements of various biological components. Recently, silicon nanowire field-effect transistors (SiNW-FETs) have been drawing enormous interest due to their potential in the biomolecular sensing field. SiNW-FETs exhibit capabilities such as providing real-time, label-free, highly selective, and sensitive detection. It is highly critical to diagnose infectious diseases accurately to reduce the illness and death spread rate. In this work, a novel SiNW-FET sensor is designed using a semiempirical approach, and the electronic transport properties are studied to detect the COVID-19 spike protein. Various electronic transport properties such as transmission spectrum, conductance, and electronic current are investigated by a semiempirical modeling that is combined with a nonequilibrium Green's function. Moreover, the developed sensor selectivity is tested by studying the electronic transport properties for other viruses including influenza, rotavirus, and HIV. The results indicate that SiNW-FET can be utilized for accurate COVID-19 identification with high sensitivity and selectivity.

9.
IEEE Trans Nanobioscience ; 21(3): 347-357, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-33945483

RESUMO

DNA sequencing techniques are critical in order to investigate genes' functions. Obtaining fast, accurate, and affordable DNA bases detection makes it possible to acquire personalized medicine. In this article, a semi-empirical technique is used to calculate the electron transport characteristics of the developed z-shaped graphene device to detect the DNA bases. The z-shaped transistor consists of a pair of zigzag graphene nanoribbon (ZGNR) connected through an armchair graphene nanoribbon (AGNR) channel with a nanopore where the DNA nucleobases are positioned. Non-equilibrium Green's function (NEGF) integrated with semi-empirical methodologies are employed to analyze the different electronic transport characteristics. The semi-empirical approach applied is an extension of the extended Hückel (EH) method integrated with self-consistent (SC) Hartree potential. By employing the NEGF+SC-EH, it is proved that each one of the four DNA nucleobases positioned within the nanopore, with the hydrogen passivated edge carbon atoms, results in a unique electrical signature. Both electrical current signal and transmission spectrum measurements of DNA nucleobases inside the device's pore are studied for the different bases with modification of their orientation and lateral translation. Moreover, the electronic noise effect of various factors is studied. The sensor sensitivity is improved by using nitrogen instead of hydrogen to passivate the nanopore and by adding a dual gate to surround the central semiconducting channel of the z-shaped graphene nanoribbon.


Assuntos
Grafite , Nanoporos , Nanotubos de Carbono , DNA/genética , Hidrogênio
10.
Carbohydr Polym ; 236: 116064, 2020 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-32172879

RESUMO

In this work, a novel selective and low temperature H2S gas sensor was fabricated based on copper (II) oxide nanoparticles (CuO NPs) in different concentrations, embedded in a conductivity-engineered organic (glycerol ionic liquid-doped chitosan) membrane/film. The sensing membranes of organic-inorganic nanocomposites (CS-IL-CuO) were prepared by casting method and were tested against H2S gas with reference to time at different temperatures and H2S gas concentrations. The fabricated sensor showed a fast response (14 s) and good sensitivity (15 ppm) towards H2S gas at a low temperature of 40 °C. Moreover, the sensor showed a high reversibility and less humidity dependence at 40 °C. Moreover, this type of hybrid nanocomposites sensor is easy and inexpensive to manufacture and is energy efficient. Thus, it has potential to be used for industrial applications in harsh environments.

11.
Sci Rep ; 9(1): 4681, 2019 03 18.
Artigo em Inglês | MEDLINE | ID: mdl-30886170

RESUMO

Here we investigated the feasibility of using microwave spectroscopy for characterization of normal and breast cancer cell lines cultured in vitro. Healthy non-tumorigenic, MCF-10A and breast cancer, MDA-MB-231, Hs578T, T47D and MCF-7 cell lines were electrically characterized using the open-ended coaxial probe technique from 200 MHz to 13.6 GHz. The dielectric constant, dielectric loss and conductivity between breast non-tumorigenic and breast cancer cells lines were analyzed and their differences determined. Our results showed that the four breast cancer cell lines analyzed exhibited higher dielectric properties when compared to healthy cells. Interestingly, we found that breast and colon cancer cells have different dielectric properties as well, thus suggesting that each type of cancer has a unique microwave signature. This study shows that microwave characterization of breast cancer cell lines is reliable with potential in biomedical applications such as designing electromagnetic models for detection of tumorous cells in healthy tissues.


Assuntos
Neoplasias da Mama/metabolismo , Mama/metabolismo , Mama/citologia , Neoplasias da Mama/diagnóstico , Neoplasias da Mama/patologia , Condutividade Elétrica , Fenômenos Eletromagnéticos , Feminino , Humanos , Células MCF-7 , Micro-Ondas , Tiazepinas
12.
Biosens Bioelectron ; 119: 191-203, 2018 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-30125881

RESUMO

DNA (deoxyribonucleic acid) is the blueprint of life as it encodes all genetic information. In genetic disorder such as gene fusion, copy number variation (CNV) and single nucleotide polymorphism, DNA sequencing is used as the gold standard for successful diagnosis. Researchers have been conducting rigorous studies to achieve genome sequence at low cost while maintaining high accuracy and high throughput, as such sequencer devices have been developed which led to the evolvement of this technology. These devices are categorized into first, second, and third DNA sequencing generations. One successful endeavor for DNA sequencing is nanopore sequencing. This specific method is considered desirable due to its ability to achieve DNA sequencing while maintaining the required standards such as low cost, high accuracy, long read length, and high throughput. On the other hand, non-nanopore sequencing techniques require extensive preparation as well as complex algorithms, and are restricted by high cost, small throughput, and small read lengths. In this review, the concepts, history, advances, challenges, applications, and potentials of nanopore sequencing are discussed including techniques and materials used for nanopore production and DNA translocation speed control. Additionally, in light of the importance of the nanopore material configuration and fabrication, graphene which is a common and effective material will be discussed in the context of nanopore fabrication techniques. Finally, this review will shed light on some nanopore-related investigations in the area of molecular biology.


Assuntos
Grafite/química , Nanoporos , Análise de Sequência de DNA/métodos , Técnicas Biossensoriais , Variações do Número de Cópias de DNA , Sequenciamento de Nucleotídeos em Larga Escala , Análise de Sequência de DNA/tendências
13.
IEEE Trans Biomed Circuits Syst ; 9(3): 353-61, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25134090

RESUMO

In this paper, we present a new differential CMOS capacitive sensor for Lab-on-Chip applications. The proposed integrated sensor features a DC-input ΣΔ capacitance to digital converter (CDC) and two reference and sensing microelectrodes integrated on the top most metal layer in 0.35 µm CMOS process. Herein, we describe a readout circuitry with a programmable clocking strategy using a Charge Based Capacitance Measurement technique. The simulation and experimental results demonstrate a high capacitive dynamic range of 100 fF-110 fF, the sensitivity of 350 mV/fF and the minimum detectable capacitance variation of as low as 10 aF. We also demonstrate and discuss the use of this device for environmental applications through various chemical solvents.


Assuntos
Técnicas Biossensoriais/instrumentação , Capacitância Elétrica , Desenho de Equipamento , Dispositivos Lab-On-A-Chip , Semicondutores
14.
PLoS One ; 9(11): e113718, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25422934

RESUMO

Signaling pathways controlling biotic and abiotic stress responses may interact synergistically or antagonistically. To identify the similarities and differences among responses to diverse stresses, we analyzed previously published microarray data on the transcriptomic responses of Arabidopsis to infection with Botrytis cinerea (a biotic stress), and to cold, drought, and oxidative stresses (abiotic stresses). Our analyses showed that at early stages after B. cinerea inoculation, 1498 genes were up-regulated (B. cinerea up-regulated genes; BUGs) and 1138 genes were down-regulated (B. cinerea down-regulated genes; BDGs). We showed a unique program of gene expression was activated in response each biotic and abiotic stress, but that some genes were similarly induced or repressed by all of the tested stresses. Of the identified BUGs, 25%, 6% and 12% were also induced by cold, drought and oxidative stress, respectively; whereas 33%, 7% and 5.5% of the BDGs were also down-regulated by the same abiotic stresses. Coexpression and protein-protein interaction network analyses revealed a dynamic range in the expression levels of genes encoding regulatory proteins. Analysis of gene expression in response to electrophilic oxylipins suggested that these compounds are involved in mediating responses to B. cinerea infection and abiotic stress through TGA transcription factors. Our results suggest an overlap among genes involved in the responses to biotic and abiotic stresses in Arabidopsis. Changes in the transcript levels of genes encoding components of the cyclopentenone signaling pathway in response to biotic and abiotic stresses suggest that the oxylipin signal transduction pathway plays a role in plant defense. Identifying genes that are commonly expressed in response to environmental stresses, and further analyzing the functions of their encoded products, will increase our understanding of the plant stress response. This information could identify targets for genetic modification to improve plant resistance to multiple stresses.


Assuntos
Arabidopsis/genética , Botrytis/patogenicidade , Secas , Micoses/genética , Estresse Oxidativo , Transcriptoma , Arabidopsis/metabolismo , Arabidopsis/microbiologia , Regulação da Expressão Gênica de Plantas
15.
Artigo em Inglês | MEDLINE | ID: mdl-24111021

RESUMO

We put forward an implantable glucometers using a biologically inspired sensor (BioS) method. In this method, engineered glucokinase (GLK) molecules are used as nanoscale glucometers. Herein, we describe two computational and experimental models of GLKs exposed to glucose molecules. The simulation results significantly show the detection of GLK binding to glucose. We thereafter reveal the applicability of this technique for continuous glucose monitoring by demonstrating and discussing the experimental results. Based on these results the glucose measurement with various glucose concentrations (0.5 mM, 1 mM and 2.5 mM) were precisely performed and repeated for more than 4 weeks. These results prove the advantage of proposed BioS method for continuous measurement of glucose.


Assuntos
Análise Química do Sangue/instrumentação , Glicemia/análise , Eletrodos Implantados , Monitorização Fisiológica/instrumentação , Enzimas Imobilizadas/química , Enzimas Imobilizadas/metabolismo , Desenho de Equipamento , Glucoquinase/química , Glucoquinase/metabolismo , Humanos
16.
Artigo em Inglês | MEDLINE | ID: mdl-23366453

RESUMO

In this paper, we describe an on-chip electroporation (EP) method for high precision nano-injection of bio-molecules into single cells. EP is an electrical stimulation method to create nano-pores on the cell plasma membrane. Herein, we first put forward the computational models of the cultured cells microelectrodes. We thereafter discuss practical considerations by demonstrating the preliminary experimental results. The mouse fibroblast cells are cultured above electrodes while experiencing a low frequency (10 Hz) electrical field (EF) in the presence of propidium iodide (PI).


Assuntos
Eletrodos , Eletroporação/métodos , Estimulação Elétrica , Modelos Teóricos
17.
Biomed Microdevices ; 11(5): 1059-70, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19488859

RESUMO

We present in this paper a new topology of inductively-coupled links based on a monolithic multi-coils receiver. A model is built to characterize the proposed structure using Matlab and is verified employing simulation tools under ADS electromagnetic environment. This topology accounts for the losses associated with the receiver micro-coil including substrate and oxide layers. The geometry of micro-coils significantly desensitizes the link to both angular and side misalignments. A custom fabrication process using 1 micron metal thickness is also presented by which two sets of micro-coils varying in the number of coils are realized. The first set possesses one coil 4 mm of diameter and represents a power efficiency close to 4% while the second set possesses multi-coils with an efficiency of 18%. The resulting optimized link can deliver up to 50 mW of power to power up an implantable device either sensor or stimulator. The experimental results for the prototypes are remarkably in agreement with those obtained from simulated models and circuits.


Assuntos
Microtecnologia/instrumentação , Modelos Teóricos , Próteses e Implantes , Eletricidade , Desenho de Equipamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...