Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
1.
Urologe A ; 47(11): 1405-16, 2008 Nov.
Artigo em Alemão | MEDLINE | ID: mdl-18797837

RESUMO

Prostate cancer is one of the principal medical problems facing the male population in developed countries with an increasing need for sophisticated imaging techniques and risk-adapted treatment options. This article presents an overview of the current imaging procedures in the diagnosis of locally advanced prostate cancer. Apart from conventional gray-scale transrectal ultrasound (TRUS) as the most frequently used primary imaging modality we describe computed tomography (CT), magnetic resonance imaging (MRI), and positron emission tomography (PET). CT and MRI not only allow assessment of prostate anatomy but also a specific evaluation of the pelvic region. Color-coded and contrast-enhanced ultrasound, real-time elastography, dynamic contrast enhancement in MR imaging, diffusion imaging, and MR spectroscopy may lead to a clinically relevant improvement in the diagnosis of prostate cancer. While bone scintigraphy with (99m)Tc-bisphosphonates is still the method of choice in the evaluation of bone metastasis, whole-body MRI and PET using (18)F-NaF, (18)F-FDG, (11)C-choline, (11)C-acetate, and (18)F-choline as tracers achieve higher sensitivities.


Assuntos
Diagnóstico por Imagem , Neoplasias da Próstata/diagnóstico , Neoplasias Ósseas/diagnóstico , Neoplasias Ósseas/patologia , Neoplasias Ósseas/secundário , Osso e Ossos/patologia , Humanos , Aumento da Imagem , Processamento de Imagem Assistida por Computador , Masculino , Estadiamento de Neoplasias , Próstata/patologia , Neoplasias da Próstata/patologia , Sensibilidade e Especificidade , Neoplasias da Coluna Vertebral/diagnóstico , Neoplasias da Coluna Vertebral/patologia , Neoplasias da Coluna Vertebral/secundário , Coluna Vertebral/patologia
2.
Aktuelle Urol ; 39(2): 135-40, 2008 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-18379967

RESUMO

PURPOSE: The aim of this study was to evaluate the different MRI diagnoses in the early and late post-operative period after renal transplantation with dysfunctional allograft. MATERIALS AND METHODS: Due to unknown transplant dysfunction, 49 patients (30-male, 19 female) received a total of 74 MRI studies. According to the date of examination all MRI studies were divided in an early (< or = 60 days, ETP) and a late post-transplant time period (> 60 days, LTP). All MRI studies were performed on 1.5 T MRI systems using a standardised imaging protocol consisting of a morphological (pre- and post-contrast enhanced T (1)- and T (2)-weighted TSE sequences), a vascular (contrast-enhanced 3D MRA) and a urographical part (Flash 3D sequences). Frequencies of diagnoses in ETP and LTP, and diagnoses within each transplant time period were analysed. RESULTS: 44/74 MRI studies were performed in ETP, 30/74 in LTP. In total 80 diagnoses were obtained: Renal artery stenosis (ETP, n = 21; LTP, n = 5), renal vein stenosis (ETP, n = 2), renal vein thrombosis (ETP, n = 2), renal perfusion defect (ETP, n = 11), rejection (ETP, n = 1; LTP, n = 2), abscess (ETP, n = 1), urinary outflow obstruction (LTP, n = 4), without MRI pathology (ETP, n = 11; LTP, n = 20). Renal artery stenosis was the most prevalent diagnosis in ETP, and a more frequent finding in ETP compared to LTP (p < 0.05). Renal perfusion defects were more frequent in ETP than in LTP (p < 0.05). In the ETP vascular diseases (34/49 diagnoses) were more frequent (p < 0.05) than uropathological diseases (0/49 diagnoses). CONCLUSIONS: Our results indicate that vascular diseases are a more frequent occurrence in the early post-operative course after renal transplantation than uropathological diseases. However, a transplant follow-up MRI study needs to contain a morphological, vascular and functional imaging part to answer combined clinical questions.


Assuntos
Transplante de Rim , Imageamento por Ressonância Magnética/métodos , Complicações Pós-Operatórias/diagnóstico , Obstrução da Artéria Renal/diagnóstico , Adulto , Idoso , Meios de Contraste , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico por imagem , Fatores de Tempo , Transplante Homólogo , Ultrassonografia Doppler Dupla , Urografia/métodos
3.
Respir Med ; 102(5): 790-2, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18207720

RESUMO

Report of an incidental chest X-ray finding of a large vessel dilation at the root of the ascending aorta in a 65-year-old female patient while pre-operative routine diagnostic. Due to prior allergic reaction to iodine contrast agent, non-invasive imaging was performed with magnetic resonance imaging (MRI), where the rare finding of a large aneurysm of the left pulmonary artery was diagnosed. Initial considerations of a surgical intervention were turned down as no clinical symptoms or risk factors were apparent.


Assuntos
Aneurisma/diagnóstico , Imagem Ecoplanar , Angiografia por Ressonância Magnética , Artéria Pulmonar , Idoso , Feminino , Humanos , Achados Incidentais
4.
Thorac Cardiovasc Surg ; 55(6): 402-5, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17721856

RESUMO

We present the case of a 53-year-old male patient with a rare complication of a thoracic wall hematoma following thoracic wall reconstruction with transverse plate fixation and pectoralis advancement flaps. The patient could be subsequently discharged after surgical re-placement and an uneventful would healing. This case marks one of two complications occurring in a series of six patients treated for deep sternal wound infection with a combination of vacuum-assisted therapy and plate fixation.


Assuntos
Placas Ósseas/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Hematoma/etiologia , Procedimentos de Cirurgia Plástica/efeitos adversos , Esterno/cirurgia , Infecção da Ferida Cirúrgica/complicações , Parede Torácica , Seguimentos , Hematoma/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos de Cirurgia Plástica/instrumentação , Infecções Estafilocócicas/complicações , Infecções Estafilocócicas/microbiologia , Staphylococcus epidermidis/isolamento & purificação , Infecção da Ferida Cirúrgica/microbiologia
5.
Rofo ; 179(9): 932-7, 2007 Sep.
Artigo em Alemão | MEDLINE | ID: mdl-17705115

RESUMO

PURPOSE: Cardiomyopathy is a rare but life-threatening disease in children and adolescents. Recent studies reported morphological, functional or metabolic alterations of the heart. We discuss a combined MR imaging and (31)P MR spectroscopy (MRS) protocol allowing the analysis of interdependencies between these parameters. Since normal values of cardiac MR parameters in this age group are not available, we included studies of age-matched healthy adolescents. MATERIALS AND METHODS: 2D-CINE was used to assess left ventricular (LV) parameters. Additional 3D-Chemical Shift Imaging (3D-CSI) and Spectral Localization with Optimal Pointspread Function (SLOOP) reconstruction allowed quantification of the cardiac energy metabolism. Patients (n = 4; all male; age 16.8 +/- 2.9 years) were included on the basis of an echocardiographic diagnosis of possible cardiomyopathy. The same protocol was applied to healthy young volunteers (n = 4; 1 female, 3 male; age 15.5 +/- 0.6 years). RESULTS: The patients had a significantly higher LV mass index compared to the control group (147 +/- 41 g/m (2) versus 97 +/- 16 g/m2; p = 0.04). The other LV parameters (including LV EF with 59 +/- 22 % versus 67 +/- 10 %) showed no significant differences. The phosphocreatine to adenosine triphosphate ratio (PCr/ATP-ratio) of the patients was reduced to 1.71 +/- 0.40 versus 2.44 +/- 0.30 (p = 0.01), combined with a tendency towards decreased PCr concentrations of 9.1 +/- 2.5 versus 7.9 +/- 1.0 mmol/kg. CONCLUSION: The combination of (31)P MR spectroscopy and MR imaging allows quantitative determination of morphologic, functional and metabolic alterations in adolescents with suspected cardiomyopathy in one examination procedure. The reduction of energy metabolism combined with unaltered global function may indicate a primary role of metabolism in the pathogenesis of cardiomyopathies in adolescents.


Assuntos
Cardiomiopatias/diagnóstico , Imagem Ecoplanar/métodos , Imagem Cinética por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos , Adolescente , Adulto , Fatores Etários , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/etiologia , Cardiomiopatias/metabolismo , Cardiomiopatias/fisiopatologia , Cardiomiopatia Dilatada/diagnóstico , Cardiomiopatia Hipertrófica/diagnóstico , Interpretação Estatística de Dados , Diagnóstico Diferencial , Ecocardiografia , Eletrocardiografia , Feminino , Humanos , Masculino , Volume Sistólico
6.
Rofo ; 179(9): 938-44, 2007 Sep.
Artigo em Alemão | MEDLINE | ID: mdl-17705116

RESUMO

PURPOSE: To evaluate the variability of coronary calcium scores depending on the image reconstruction interval using a 64-slice CT scanner. MATERIALS AND METHODS: 30 patients (18 male, 12 female; mean age 57 +/- 9 yrs; mean heart rate 66 +/- 10 bpm) underwent coronary calcium scoring using a 64-slice CT scanner (Somatom Sensation 64, Siemens Medical Solutions, Erlangen) and a standardized scanning protocol. Oral beta-blockers were administered to 12 patients with a baseline heart rate > 70 bpm. Images were reconstructed in 10 % increments from 10 - 100 % of the RR interval. Two blinded experienced observers independently calculated Agatston (AS), calcium mass (MS) and volume scores (VS) for every reconstructed image series. The results were compared to similar studies for 16-slice CT scanners. RESULTS: The mean values and mean coefficients of variation among all patients were as follows: AS, 397 +/- 829, 109 % MS, 88 +/- 225, 154 % VS, 335 +/- 669, 100 %. Regarding the reconstruction intervals, the mean coefficients of variation were as follows: 107 % (AS), 97 % (VS), 116 % (MS). No specific image reconstruction interval with statistically significant lower variability for each score could be identified. High inter-observer agreement was achieved (K = 0.98). With statistical significance (p < 0.05) 10/30 patients (pts) were able to be allocated to more than one risk group (RG): 6 pts = 2 RG; 3 pts = 3 RG; 1 pts = 4 RG. The scores for 5/30 patients were zero for at least one reconstruction interval, but further reconstructions revealed calcifications. The number of patients assignable to different risk groups was significantly lower compared to published data using a 16-slice scanner (p < 0.05). CONCLUSION: Coronary calcium scores determined using a 64-slice scanner display a wide range of variability depending on the image reconstruction interval as already described for 16-slice CT scanners. However, compared to previous studies, our data indicate that this vendor's generation of scanners reduces the influence of score variations on the risk stratification.


Assuntos
Calcinose/diagnóstico por imagem , Doença das Coronárias/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Administração Oral , Antagonistas Adrenérgicos beta/administração & dosagem , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Cálcio/metabolismo , Doença das Coronárias/metabolismo , Interpretação Estatística de Dados , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Fatores Sexuais
7.
Acta Radiol ; 48(6): 620-7, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17611868

RESUMO

BACKGROUND: Cardiac computed tomography (CT) has become an established complement in cardiac imaging. Thus, optimized image quality is diagnostically crucial. PURPOSE: To prospectively evaluate whether, by using 64-slice CT, a specific reconstruction interval can be identified providing best image quality for all coronary artery segments and each individual coronary artery. MATERIAL AND METHODS: 311 coronary segments of 14 men and seven women were analyzed using 64-slice CT. Data reconstruction was performed in 5% increments from 5-100% of the R-R interval. Four experienced observers independently evaluated image quality of the coronary arteries according to the AHA classification. A three-point ranking scale was applied: 1, very poor, no evaluation possible; 2, diagnostically sufficient quality; 3, highest image quality, no artifacts. RESULTS: The best reconstruction point for all segments was found to be 65% of the R-R interval (mean value 2.4+/-0.5; P<0.05). On a per-artery basis, best image quality was again achieved at 65% of the R-R interval: RCA 2.2+/-0.4, LCA 2.4+/-0.5, LM 2.5+/-0.2, LAD 2.3+/-0.4, LCX 2.3+/-0.5. CONCLUSION: By using 64-slice CT, the need for adjusting the reconstruction point to each coronary segment might be overcome. Best image quality was achieved with image reconstruction at 65% of the R-R interval for all coronary segments as well as each coronary artery.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Prospectivos , Reprodutibilidade dos Testes , Fatores de Tempo
10.
Br J Radiol ; 77(913): 68-70, 2004 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-14988143

RESUMO

Mediastinal lipomas are slowly growing tumours. Only very few cases have been reported in children. None of these included a rapidly enlarging lipoma. We present an 8-year-old severely adipose girl with an incidentally diagnosed mediastinal lipoma that showed rapid enlargement within 7 weeks.


Assuntos
Lipoma/patologia , Neoplasias do Mediastino/patologia , Criança , Feminino , Humanos , Lipoma/diagnóstico por imagem , Angiografia por Ressonância Magnética , Neoplasias do Mediastino/diagnóstico por imagem , Radiografia , Ultrassonografia
11.
Acta Radiol ; 44(4): 411-8, 2003 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12846692

RESUMO

Peripheral arterial occlusive disease (PAOD) of the lower limb is a widely spread disease at the present time. After clinical examination, which includes a comprehensive history of the patient, different imaging modalities are competitive in the exact assessment of PAOD. Besides digital subtraction angiography and MR -angiography, color Doppler US is an established imaging modality in the diagnosis of PAOD. This article illustrates the typical color Doppler US findings in PAOD of the lower limb. Duplex images of normal and pathological findings are presented, and the limitations of the method are pointed out. Color Doppler US examination strategies in patients suffering of PAOD are outlined.


Assuntos
Arteriopatias Oclusivas/diagnóstico por imagem , Perna (Membro)/irrigação sanguínea , Doenças Vasculares Periféricas/diagnóstico por imagem , Ultrassonografia Doppler em Cores , Humanos , Ultrassonografia Doppler em Cores/métodos
12.
Ultraschall Med ; 23(4): 245-50, 2002 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12226762

RESUMO

AIM: In patients with lesions of the liver we compared diagnoses based on different methods of ultrasound as well as spiral CT with the final diagnosis reached at the time of the patient's discharge from hospital. METHOD: From records of a prospective multicentre study including 90 liver lesions investigated with B-mode baseline and conventional colour/power Doppler ultrasound, contrast-enhanced colour/power Doppler ultrasound and spiral-CT, we evaluated only those where diagnoses for all modalities were available, and where the diagnosis at discharge comprising all clinical, laboratory and imaging data as well as histologic proof was at least "highly probable". RESULTS: 60 lesions met the inclusion criteria. 20 lesions were ultimately diagnosed as benign, and 40 as malignant. With respect to the diagnosis of malignancy, sensitivity was 92.5 % (37/40) with B-mode and unenhanced conventional colour/power Doppler US ultrasound, 97.5 % (39/40) with contrast-enhanced colour/ power Doppler ultrasound, and 100 % with CT; the corresponding specificities were 65 % (13/20), 85 % (17/20) and 80 % (16/20). 4 of 7 false positive, and 2 of 3 false negative results in the unenhanced technique were diagnosed correctly with contrast-enhanced Doppler ultrasound. CONCLUSION: Compared to conventional ultrasound, contrast-enhanced Doppler ultrasound improved the diagnostic accuracy in 10 % of the cases. Its accuracy in our study was equal to that of CT.


Assuntos
Neoplasias Hepáticas/diagnóstico por imagem , Ultrassonografia Doppler em Cores/métodos , Meios de Contraste , Ecocardiografia Doppler em Cores/métodos , Humanos , Processamento de Imagem Assistida por Computador , Neoplasias Hepáticas/classificação , Radiografia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
13.
Z Gastroenterol ; 40(7): 503-10, 2002 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12122598

RESUMO

BACKGROUND: In the light of the clinical controversy whether metallic stents or plastic endoprostheses should be used in the percutaneous treatment of biliary obstruction we retrospectively evaluated our experience with both drainage-systems. METHODS: 71 patients (mean age 68 +/- 12 years) underwent a total of 81 interventions and received either plastic endoprostheses (11.5 or 12 French diameter; N = 57/81) or metallic stents (N = 24/81). RESULTS: Drainage insertion was technically successful in all of the 71 patients. There was no procedure-related mortality, but a 30-day mortality of 15 % (N = 11). Overall, 27 complications occurred in 81 interventions with a statistically significant higher complication-rate in plastic endoprostheses (39 %; N = 21/54) compared to metallic stents (22 %; N = 6/27). The average patency of the drainage-systems was 166 +/- 341 days (range 1-2,705 days) and did not differ significantly between the drainage-subtypes. Incidence of complications and a further increase in serum bilirubin following intervention was associated with a higher drainage occlusion-rate and reduced survival, irrespective of the drainage-system used. CONCLUSIONS: Percutaneous transhepatic treatment of biliary obstructions with internal drainages is a reliable therapy. The overall complication-rate of metallic stents was lower compared to plastic endoprostheses; however, no significant differences were found with respect to drainage patency or success-rate.


Assuntos
Neoplasias dos Ductos Biliares/terapia , Colestase/terapia , Metais , Plásticos , Próteses e Implantes , Stents , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias dos Ductos Biliares/sangue , Neoplasias dos Ductos Biliares/mortalidade , Bilirrubina/sangue , Colestase/sangue , Colestase/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cuidados Paliativos , Desenho de Prótese , Falha de Prótese , Estudos Retrospectivos , Taxa de Sobrevida , Resultado do Tratamento
14.
Abdom Imaging ; 27(1): 40-2, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-11740605

RESUMO

Angiomyoma is a benign tumor that arises from soft muscular tissue within the blood vessel wall. This lesion has been found in different organs. The preferential location of these tumors is the lower extremity. We describe the rare case of a hepatic angiomyoma and present the radiologic findings of computed tomography and magnetic resonance imaging.


Assuntos
Angiomioma/diagnóstico , Neoplasias Hepáticas/diagnóstico , Diagnóstico Diferencial , Feminino , Humanos , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X
15.
J Ultrasound Med ; 20(9): 953-7, 2001 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-11549154

RESUMO

OBJECTIVE: To compare axial reconstructed ultrasonographic images from three-dimensional data volumes and conventional computed tomographic scans in documentation and detection of liver lesions. METHODS: The livers of 23 patients were examined by a multifrequency curved array transducer to acquire three-dimensional data volumes and by conventional computed tomography The ultrasonographic device was equipped with three-dimensional ultrasonographic technology allowing for real-time parallel movement in every plane within an acquired data volume. Axial ultrasonographic images reconstructed from three-dimensional data volumes were compared with conventional computed tomographic scans. RESULTS: When both methods were taken together, a total of 51 different liver lesions could be detected. Reconstructed ultrasonographic images depicted 44 (86%) of 51 lesions, and computed tomographic scans showed 46 (90%) of 51 lesions. Compared with computed tomography, ultrasonography depicted 5 additional lesions in 3 of the patients (4 hemagiomas and 1 unspecified lesion), whereas 7 lesions were missed in another 4 patients (4 metastases, 2 calcifications, and 1 cyst). The Pearson correlation coefficient between ultrasonography and computed tomography was r = 0.84 (P < .001). CONCLUSIONS: Our study shows that ultrasonographic images can be effectively reconstructed from three-dimensional data volumes. With respect to documentation and detection of liver lesions, the results obtained by three-dimensional ultrasonography appear comparable with those obtained by conventional computed tomography. However, several technical and procedural limitations have to be respected.


Assuntos
Imageamento Tridimensional , Hepatopatias/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adulto , Idoso , Carcinoma Hepatocelular/diagnóstico por imagem , Diagnóstico Diferencial , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Metástase Neoplásica/diagnóstico por imagem , Ultrassonografia
16.
MMW Fortschr Med ; 143(17): 29-33, 2001 Apr 26.
Artigo em Alemão | MEDLINE | ID: mdl-11490502

RESUMO

Ultrasound in B-mode or tissue harmonic imaging is the procedure of first choice for investigating the liver. If US is employed to screen for metastatic disease, B-mode contrast harmonic imaging should be used in addition to conventional ultrasound. For the diagnosis "space-consuming liver lesion", the echogenicity and clinical aspects determine the further diagnostic procedure. Echogenic liver lesions in patients with known malignant disease, and echo-poor or "echo-complex" lesions always indicate a need for further spiral CT or MRT investigations. In tumour patients, spiral CT offers the advantage of enabling simultaneous evaluation of the parenchyma, and abdominal staging. Primary SPIO-amplified MRT is indicated whenever the primary interest is the detection of space-consuming liver lesions. In the case of echogenic lesions in the absence of underlying malignant disease, US follow-up suffices. Here, differential diagnostic information can be gained from the vascular distribution patterns of a lesion obtained with color-coded duplex US. Hepatic lesions that, after exhausting all diagnostic imaging procedures remain suspicious, require biopsy.


Assuntos
Diagnóstico por Imagem , Neoplasias Hepáticas/diagnóstico , Diagnóstico Diferencial , Humanos , Aumento da Imagem , Fígado/patologia , Valor Preditivo dos Testes
17.
J Ultrasound Med ; 20(4): 409-12, 2001 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11316319

RESUMO

Noninvasive treatment of ruptured postcatheterization pseudoaneurysms is rare. We report the use of ultrasonographically guided compression repair for the treatment of ruptured pseudoaneurysms in 2 cases. To ensure the immediate stop of bleeding, more compression was applied than for nonruptured pseudoaneurysms, regardless of flow in the femoral artery or vein, thus maximizing the effectiveness of this therapy. With this method, complete thrombosis of the pseudoaneurysm could be achieved in less than 30 minutes. In both cases, ultrasonographically guided compression repair was faster than the time needed to prepare an operating room for surgical treatment. In follow-up examinations, no recurrences or further complications were detected. Ultrasonographically guided compression repair can be used for noninvasive treatment of ruptured pseudoaneurysms in some cases, provided that more compression than indicated for nonruptured pseudoaneurysms is applied. Further clinical experience with more patients will be necessary to determine the exact benefits and possible limitations.


Assuntos
Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/terapia , Aneurisma Roto/diagnóstico por imagem , Aneurisma Roto/terapia , Artéria Femoral , Ultrassonografia Doppler em Cores , Ultrassonografia de Intervenção , Idoso , Falso Aneurisma/etiologia , Cateterismo Periférico/efeitos adversos , Feminino , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/lesões , Humanos , Masculino , Pessoa de Meia-Idade , Pressão
18.
Rofo ; 173(2): 133-8, 2001 Feb.
Artigo em Alemão | MEDLINE | ID: mdl-11253085

RESUMO

PURPOSE: To compare easy-to-perform three-dimensional power Doppler ultrasound (3D PDUS) to color Doppler ultrasound (CDUS) and digital subtraction angiography (DSA) in the assessment of internal carotid artery (ICA) stenoses in patients with severe atherosclerosis. METHODS: 26 ICA's (7 without stenosis, 4 low-, 4 middle-, and 11 high-grade stenoses) in 13 patients were examined with DSA, CDUS, and 3D PDUS. CDUS and 3D PDUS were performed with a 7.5 MHz standard transducer and a Sonoline Elegra ultrasound machine. The three methods were performed and interpreted by different persons who were not aware of the diagnoses. RESULTS: Regarding the degree of stenosis correlations between DSA and 3D PDUS were r = 0.98 (p < 0.001), between DSA and CDUS r = 0.97 (p < 0.001), and between CDUS and 3D PDUS r = 0.95 (p < 0.001). Sensitivity and specificity regarding the detection of a high-degree stenosis was 90% and 100% for 3D PDUS, and 100% and 93.3% for CDUS. CONCLUSION: Even in cases with severe atherosclerosis, both sonographic methods reveal similar results comparable to DSA. 3D PDUS does not result in a diagnostic improvement on CDUS, however, it does give the new opportunity for complete data storage, reconstruction, and survey presentations.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença das Coronárias/diagnóstico por imagem , Ultrassonografia Doppler em Cores/métodos , Idoso , Ecocardiografia , Ecocardiografia Tridimensional , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Análise de Regressão , Reprodutibilidade dos Testes
19.
J Clin Ultrasound ; 28(9): 441-51, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-11056021

RESUMO

PURPOSE: Color Doppler sonography has gained considerable recognition as a noninvasive method to detect carotid artery disease and to assess the degree of carotid artery stenosis. However, results are highly operator-dependent and cannot be presented as survey images. The purpose of this study was to evaluate real-time 3-dimensional (3D) power Doppler sonography as a method for screening for atherosclerosis in the carotid arteries. METHODS: We prospectively screened 75 patients for carotid artery disease using both conventional color Doppler sonography and 3D power Doppler sonography, and the results from the 2 modalities were compared. A total of 150 common carotid arteries, 150 internal carotid arteries, and 150 external carotid arteries were examined utilizing a 7.5-MHz linear-array transducer combined with tissue harmonic imaging. RESULTS: Color Doppler sonography detected 297 normal or atherosclerotic arteries without stenosis, 57 arteries with mild (1-49%) stenosis, 41 with moderate (50-69%) stenosis, 32 with severe (70-99%) stenosis, and 9 with occlusions. The degree of stenosis determined by color Doppler sonography correlated with that determined by 3D power Doppler sonography (r = 0.982-0.998). Moreover, there was a good correlation between the measurements for both the length of the lesion and its distance from the bulb as determined by the 3D volume surveys and by color Doppler sonography (r = 0.986). The interobserver variability rate was 3.7% +/- 0.5%. Generally, the acquisition and reconstruction of the 3D data took less than 5 minutes. CONCLUSIONS: 3D power Doppler sonography is easy to perform and is an accurate method in screening for atherosclerotic lesions of the carotid arteries. Moreover, it provides excellent 3D volume surveys that may be helpful in the planning of surgical treatment.


Assuntos
Doenças das Artérias Carótidas/diagnóstico por imagem , Imageamento Tridimensional , Programas de Rastreamento , Ultrassonografia Doppler , Idoso , Idoso de 80 Anos ou mais , Doenças das Artérias Carótidas/classificação , Artéria Carótida Primitiva/diagnóstico por imagem , Artéria Carótida Externa/diagnóstico por imagem , Artéria Carótida Interna/diagnóstico por imagem , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Estudos Prospectivos , Sensibilidade e Especificidade , Fatores de Tempo , Transdutores , Ultrassonografia Doppler/instrumentação , Ultrassonografia Doppler em Cores/instrumentação
20.
Rofo ; 172(4): 361-6, 2000 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-10961221

RESUMO

PURPOSE: Comparison between contrast harmonic imaging (CHI) in B-mode with stimulated acoustic emission (SAE), conventional B-mode US, and spiral CT in the detection of focal liver lesions. METHODS: In this pilot study 26 patients with liver lesions diagnosed by B-mode US and contrast-enhanced spiral-CT were additionally examined with CHI in B-mode. Each examination started with a bolus injection of 4 g of the US contrast agent Levovist (300 mg/ml) after a delay of at least 5 minutes to ensure liver-specific phase. All examinations were documented on video tapes and analysed by two radiologists. RESULTS: 81 liver lesions were diagnosed with both US examinations and spiral CT. B-mode US detected 66 lesions, CHI with SAE 72 lesions, and spiral CT 73 lesions. Compared to spiral CT 8 lesions in 3 patients could be depicted additionally with both US methods. Metastases and HCC present in CHI with SAE as not-enhancing signal contrast agent areas. Delineation of haemangiomas and FNH was often worse compared to the native examinations. CONCLUSION: The new US method CHI with SAE depicted more lesions than conventional B-mode US and is in some cases superior to spiral CT.


Assuntos
Meios de Contraste , Hepatopatias/diagnóstico por imagem , Polissacarídeos , Tomografia Computadorizada por Raios X/métodos , Ultrassonografia/métodos , Adulto , Idoso , Carcinoma Hepatocelular/diagnóstico por imagem , Cistos/diagnóstico por imagem , Diagnóstico Diferencial , Feminino , Hemangioma/diagnóstico por imagem , Humanos , Abscesso Hepático/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/secundário , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...