Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Biol Chem ; 295(8): 2359-2374, 2020 02 21.
Artigo em Inglês | MEDLINE | ID: mdl-31896573

RESUMO

The maternal embryonic leucine zipper kinase (MELK) has been implicated in the regulation of cancer cell proliferation. RNAi-mediated MELK depletion impairs growth and causes G2/M arrest in numerous cancers, but the mechanisms underlying these effects are poorly understood. Furthermore, the MELK inhibitor OTSSP167 has recently been shown to have poor selectivity for MELK, complicating the use of this inhibitor as a tool compound to investigate MELK function. Here, using a cell-based proteomics technique called multiplexed kinase inhibitor beads/mass spectrometry (MIB/MS), we profiled the selectivity of two additional MELK inhibitors, NVS-MELK8a (8a) and HTH-01-091. Our results revealed that 8a is a highly selective MELK inhibitor, which we further used for functional studies. Resazurin and crystal violet assays indicated that 8a decreases triple-negative breast cancer cell viability, and immunoblotting revealed that impaired growth is due to perturbation of cell cycle progression rather than induction of apoptosis. Using double-thymidine synchronization and immunoblotting, we observed that MELK inhibition delays mitotic entry, which was associated with delayed activation of Aurora A, Aurora B, and cyclin-dependent kinase 1 (CDK1). Following this delay, cells entered and completed mitosis. Using live-cell microscopy of cells harboring fluorescent proliferating cell nuclear antigen, we confirmed that 8a significantly and dose-dependently lengthens G2 phase. Collectively, our results provide a rationale for using 8a as a tool compound for functional studies of MELK and indicate that MELK inhibition delays mitotic entry, likely via transient G2/M checkpoint activation.


Assuntos
Espectrometria de Massas , Mitose , Inibidores de Proteínas Quinases/farmacologia , Proteínas Serina-Treonina Quinases/antagonistas & inibidores , Linhagem Celular Tumoral , Sobrevivência Celular/efeitos dos fármacos , Histonas/metabolismo , Humanos , Mitose/efeitos dos fármacos , Proteínas de Neoplasias/metabolismo , Fosforilação/efeitos dos fármacos , Proteínas Serina-Treonina Quinases/metabolismo , Neoplasias de Mama Triplo Negativas/enzimologia , Neoplasias de Mama Triplo Negativas/patologia
2.
Cell Chem Biol ; 27(1): 47-56.e15, 2020 01 16.
Artigo em Inglês | MEDLINE | ID: mdl-31831267

RESUMO

Protein degradation via the use of bivalent chemical degraders provides an alternative strategy to block protein function and assess the biological roles of putative drug targets. This approach capitalizes on the advantages of small-molecule inhibitors while moving beyond the restrictions of traditional pharmacology. Here, we report a chemical degrader (UNC6852) that targets polycomb repressive complex 2 (PRC2). UNC6852 contains an EED226-derived ligand and a ligand for VHL which bind to the WD40 aromatic cage of EED and CRL2VHL, respectively, to induce proteasomal degradation of PRC2 components, EED, EZH2, and SUZ12. Degradation of PRC2 with UNC6852 blocks the histone methyltransferase activity of EZH2, decreasing H3K27me3 levels in HeLa cells and diffuse large B cell lymphoma (DLBCL) cells containing EZH2 gain-of-function mutations. UNC6852 degrades both wild-type and mutant EZH2, and additionally displays anti-proliferative effects in this cancer model system.


Assuntos
Inibidores Enzimáticos/farmacologia , Complexo Repressor Polycomb 2/metabolismo , Proteólise/efeitos dos fármacos , Linhagem Celular Tumoral , Inibidores Enzimáticos/química , Células HeLa , Humanos , Ligantes , Estrutura Molecular
3.
Sci Rep ; 8(1): 16334, 2018 11 05.
Artigo em Inglês | MEDLINE | ID: mdl-30397248

RESUMO

We use shotgun proteomics to identify biomarkers of diagnostic and prognostic value in individuals diagnosed with amyotrophic lateral sclerosis. Matched cerebrospinal and plasma fluids were subjected to abundant protein depletion and analyzed by nano-flow liquid chromatography high resolution tandem mass spectrometry. Label free quantitation was used to identify differential proteins between individuals with ALS (n = 33) and healthy controls (n = 30) in both fluids. In CSF, 118 (p-value < 0.05) and 27 proteins (q-value < 0.05) were identified as significantly altered between ALS and controls. In plasma, 20 (p-value < 0.05) and 0 (q-value < 0.05) proteins were identified as significantly altered between ALS and controls. Proteins involved in complement activation, acute phase response and retinoid signaling pathways were significantly enriched in the CSF from ALS patients. Subsequently various machine learning methods were evaluated for disease classification using a repeated Monte Carlo cross-validation approach. A linear discriminant analysis model achieved a median area under the receiver operating characteristic curve of 0.94 with an interquartile range of 0.88-1.0. Three proteins composed a prognostic model (p = 5e-4) that explained 49% of the variation in the ALS-FRS scores. Finally we investigated the specificity of two promising proteins from our discovery data set, chitinase-3 like 1 protein and alpha-1-antichymotrypsin, using targeted proteomics in a separate set of CSF samples derived from individuals diagnosed with ALS (n = 11) and other neurological diseases (n = 15). These results demonstrate the potential of a panel of targeted proteins for objective measurements of clinical value in ALS.


Assuntos
Esclerose Lateral Amiotrófica/sangue , Esclerose Lateral Amiotrófica/líquido cefalorraquidiano , Aprendizado de Máquina , Proteômica , Esclerose Lateral Amiotrófica/metabolismo , Humanos , Análise Multivariada
4.
Anal Bioanal Chem ; 410(10): 2597-2605, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29455280

RESUMO

We describe a set of new tools for the detection and quantification of ß-N-methylamino-L-alanine (BMAA) which includes a novel stable isotope-labeled BMAA standard (13C3,15N2) and a chip-based capillary electrophoresis mass spectrometry platform for separation and detection. Baseline resolution of BMAA from its potentially confounding structural isomers N-2-aminoethylglycine (AEG) and 2,4-diaminobutyric acid (2,4-DAB) is achieved using the chip-based CE-MS system in less than 1 min. Detection and linearity of response are demonstrated across > 3.5 orders of dynamic range using parallel reaction monitoring (PRM). The lower limit of detection and quantification were calculated for BMAA detection at 40 nM (4.8 ng/mL) and 400 nM (48 ng/mL), respectively. Finally, the strategy was applied to detect BMAA in seafood samples purchased at a local market in Raleigh, NC where their harvest location was known. BMAA was detected in a sea scallop sample. Because the BMAA/stable isotope-labeled 13C3,15N2-BMAA (SIL-BMAA) ratio in the scallop sample was below the limit of quantification, a semiquantitative analysis of BMAA content was carried out, and BMAA content was estimated to be approximately 820 ng BMAA/1 g of wet scallop tissue. Identification was verified by high mass measurement accuracy of precursor (< 5 ppm) and product ions (< 10 ppm), comigration with SIL-BMAA spike-in standard, and conservation of ion abundance ratios for product ions between BMAA and SIL-BMAA. Interestingly, BMAA was not identified in the free protein fraction but only detected after protein hydrolysis which suggests that BMAA is tightly bound by and/or incorporated into proteins. Graphical abstract Utilization of novel 13C3,15N2-BMAA and chip-based CE-MS/MS for detection and quantification of BMAA in environmental samples.


Assuntos
Diamino Aminoácidos/análise , Poluentes Ambientais/análise , Neurotoxinas/análise , Espectrometria de Massas em Tandem/métodos , Animais , Toxinas de Cianobactérias , Monitoramento Ambiental/métodos , Peixes/metabolismo , Análise de Alimentos/métodos , Humanos , Limite de Detecção , Alimentos Marinhos/análise
5.
Proteomics ; 17(17-18)2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28837265

RESUMO

The goal of this study is to investigate the molecular pathways perturbed by in vitro exposure of beta-methylamino-L-alanine (BMAA) to NSC-34 cells via contemporary proteomics. Our analysis of differentially regulated proteins reveals significant enrichment (p < 0.01) of pathways related to ER stress, protein ubiquitination, the unfolded protein response, and mitochondrial dysfunction. Upstream regulator analysis indicates that exposure to BMAA induces activation of transcription factors (X-box binding protein 1; nuclear factor 2 erythroid like 2; promyelocytic leukemia) involved in regulation of the UPR, oxidative stress, and cellular senescence. Furthermore, the authors examine the hypothesis that BMAA causes protein damage via misincorporation in place of L-Serine. The authors are unable to detect misincorporation of BMAA into protein via analysis of cellular protein, secreted protein, targeted detection of BMAA after protein hydrolysis, or through the use of in vitro protein translation kits.


Assuntos
Diamino Aminoácidos/toxicidade , Esclerose Lateral Amiotrófica/induzido quimicamente , Agonistas de Aminoácidos Excitatórios/toxicidade , Regulação da Expressão Gênica/efeitos dos fármacos , Neurônios Motores/metabolismo , Neuroblastoma/metabolismo , Esclerose Lateral Amiotrófica/metabolismo , Esclerose Lateral Amiotrófica/patologia , Animais , Linhagem Celular , Toxinas de Cianobactérias , Dieta/efeitos adversos , Camundongos , Neurônios Motores/patologia , Neuroblastoma/patologia
6.
J Proteome Res ; 15(12): 4763-4769, 2016 12 02.
Artigo em Inglês | MEDLINE | ID: mdl-27700092

RESUMO

We report the development of a completely automated pipeline to monitor system suitability in bottom-up proteomic experiments. LC-MS/MS runs are automatically imported into Skyline and multiple identification-free metrics are extracted from targeted peptides. These data are then uploaded to the Panorama Skyline document repository where metrics can be viewed in a web-based interface using powerful process control techniques, including Levey-Jennings and Pareto plots. The interface is versatile and takes user input, which allows the user significant control over the visualization of the data. The pipeline is vendor and instrument-type neutral, supports multiple acquisition techniques (e.g., MS 1 filtering, data-independent acquisition, parallel reaction monitoring, and selected reaction monitoring), can track performance of multiple instruments, and requires no manual intervention aside from initial setup. Data can be viewed from any computer with Internet access and a web browser, facilitating sharing of QC data between researchers. Herein, we describe the use of this pipeline, termed Panorama AutoQC, to evaluate LC-MS/MS performance in a range of scenarios including identification of suboptimal instrument performance, evaluation of ultrahigh pressure chromatography, and identification of the major sources of variation throughout years of peptide data collection.


Assuntos
Automação , Cromatografia Líquida/normas , Proteômica/métodos , Espectrometria de Massas em Tandem/normas , Fluxo de Trabalho , Cromatografia Líquida/métodos , Disseminação de Informação , Internet , Espectrometria de Massas em Tandem/métodos
7.
Anal Chem ; 87(23): 11635-40, 2015 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-26537636

RESUMO

We present a novel proteomic standard for assessing liquid chromatography-tandem mass spectrometry (LC-MS/MS) instrument performance, in terms of chromatographic reproducibility and dynamic range within a single LC-MS/MS injection. The peptide mixture standard consists of six peptides that were specifically synthesized to cover a wide range of hydrophobicities (grand average hydropathy (GRAVY) scores of -0.6 to 1.9). A combination of stable isotope labeled amino acids ((13)C and (15)N) were inserted to create five isotopologues. By combining these isotopologues at different ratios, they span four orders of magnitude within each distinct peptide sequence. Each peptide, from lightest to heaviest, increases in abundance by a factor of 10. We evaluate several metrics on our quadrupole orbitrap instrument using the 6 × 5 LC-MS/MS reference mixture spiked into a complex lysate background as a function of dynamic range, including mass measurement accuracy (MMA) and the linear range of quantitation of MS1 and parallel reaction monitoring experiments. Detection and linearity of the instrument routinely spanned three orders of magnitude across the gradient (500 fmol to 0.5 fmol on column) and no systematic trend was observed for MMA of targeted peptides as a function of abundance by analysis of variance analysis (p = 0.17). Detection and linearity of the fifth isotopologue (i.e., 0.05 fmol on column) was dependent on the peptide and instrument scan type (MS1 vs PRM). We foresee that this standard will serve as a powerful method to conduct both intra-instrument performance monitoring/evaluation, technology development, and inter-instrument comparisons.


Assuntos
Cromatografia Líquida/métodos , Indicadores e Reagentes/química , Peptídeos/química , Proteômica/métodos , Espectrometria de Massas em Tandem/métodos , Aminoácidos/química , Células HEK293 , Humanos , Interações Hidrofóbicas e Hidrofílicas , Peptídeos/síntese química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...