1.
Invest Radiol ; 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38709665

RESUMO

RATIONALE AND OBJECTIVES: This study investigates the performance of tomosynthesis in the presence of osteosynthetic implants, aiming to overcome superimposition-induced limitations in conventional radiograms. MATERIALS AND METHODS: After surgical fracture induction and subsequent osteosynthesis, 8 cadaveric fracture models (wrist, metacarpus, ankle, metatarsus) were scanned with the prototypical tomosynthesis mode of a multiuse x-ray system. Tomosynthesis protocols at 60, 80, and 116 kV (sweep angle 10°, 13 FPS) were compared with standard radiograms. Five radiologists independently rated diagnostic assessability based on an equidistant 7-point scale focusing on fracture delineation, intra-articular screw placement, and implant positioning. The intraclass correlation coefficient (ICC) was calculated to analyze interrater agreement. RESULTS: Radiation dose in radiography was 0.48 ± 0.26 dGy·cm2 versus 0.12 ± 0.01, 0.36 ± 0.02, and 1.95 ± 0.11 dGy·cm2 for tomosynthesis scans at 60, 80, and 116 kV. Delineation of fracture lines was superior for 80/116 kV tomosynthesis compared with radiograms (P ≤ 0.003). Assessability of intra-articular screw placement was deemed favorable for all tomosynthesis protocols (P ≤ 0.004), whereas superiority for evaluation of implant positioning could not be ascertained (all P's ≥ 0.599). Diagnostic confidence was higher for 80/116 kV tomosynthesis versus radiograms and 60 kV tomosynthesis (P ≤ 0.002). Interrater agreement was good for fracture delineation (ICC, 0.803; 95% confidence interval [CI], 0.598-0.904), intra-articular screw placement (ICC, 0.802; 95% CI, 0.599-0.903), implant positioning (ICC, 0.855; 95% CI, 0.729-0.926), and diagnostic confidence (ICC, 0.842; 95% CI, 0.556-0.934). CONCLUSIONS: In the postoperative workup of extremity fractures, tomosynthesis allows for superior assessment of fracture lines and intra-articular screw positioning with greater diagnostic confidence at radiation doses comparable to conventional radiograms.

2.
Sci Rep ; 14(1): 9358, 2024 04 23.
Artigo em Inglês | MEDLINE | ID: mdl-38653758

RESUMO

The goal of this experimental study was to quantify the influence of helical pitch and gantry rotation time on image quality and file size in ultrahigh-resolution photon-counting CT (UHR-PCCT). Cervical and lumbar spine, pelvis, and upper legs of two fresh-frozen cadaveric specimens were subjected to nine dose-matched UHR-PCCT scan protocols employing a collimation of 120 × 0.2 mm with varying pitch (0.3/1.0/1.2) and rotation time (0.25/0.5/1.0 s). Image quality was analyzed independently by five radiologists and further substantiated by placing normed regions of interest to record mean signal attenuation and noise. Effective mAs, CT dose index (CTDIvol), size-specific dose estimate (SSDE), scan duration, and raw data file size were compared. Regardless of anatomical region, no significant difference was ascertained for CTDIvol (p ≥ 0.204) and SSDE (p ≥ 0.240) among protocols. While exam duration differed substantially (all p ≤ 0.016), the lowest scan time was recorded for high-pitch protocols (4.3 ± 1.0 s) and the highest for low-pitch protocols (43.6 ± 15.4 s). The combination of high helical pitch and short gantry rotation times produced the lowest perceived image quality (intraclass correlation coefficient 0.866; 95% confidence interval 0.807-0.910; p < 0.001) and highest noise. Raw data size increased with acquisition time (15.4 ± 5.0 to 235.0 ± 83.5 GByte; p ≤ 0.013). Rotation time and pitch factor have considerable influence on image quality in UHR-PCCT and must therefore be chosen deliberately for different musculoskeletal imaging tasks. In examinations with long acquisition times, raw data size increases considerably, consequently limiting clinical applicability for larger scan volumes.


Assuntos
Fótons , Humanos , Tomografia Computadorizada por Raios X/métodos , Cadáver , Rotação , Doses de Radiação , Tomografia Computadorizada Espiral/métodos
3.
Pediatr Rep ; 16(1): 190-200, 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38535513

RESUMO

PURPOSE: To compare suprapubic access (SPA) and transurethral catheterization (TUC) in voiding cystourethrogram (VCUG). METHODS: Retrospective single-center evaluation of 311 VCUG performed in male patients under 12 years of age. Two study groups were built based on the bladder access method. TUC was performed in 213 patients, whereas 98 received SPA. The groups were compared regarding the procedural switch rate, the complication rate, radiation parameters, the amount of contrast media applied and the examination quality. Complications were graded in minor (contrast leakage, premature termination of the examination) and major (fever, urinary tract infection, bladder perforation). Fluoroscopy time and radiation parameters were compared. Examination quality was assessed based on the satisfactory acquisition of fluoroscopic images using a four-point Likert scale. RESULTS: In 9% of the SPA examinations a method switch to TUC was necessary. The minor complication rate was 1.9% for TUC and 35.7% for SPA (p < 0.001). The major complication rate was 0.9% for TUC and 2% for SPA (p > 0.05). Mean fluoroscopy time and radiation dose were significantly lower in TUC (TUC, 26 ± 19 s, 0.6 ± 1.2 µGy·m2; SPA, 38 ± 33 s, 1.7 ± 2.9 µGy·m2; p = 0.01/0.001). There was no significant difference regarding the amount of contrast media applied (TUC, 62 ± 40 mL; SPA, 66 ± 41 mL; p > 0.05) and the examination quality with full diagnostic quality achieved in 88% of TUC and 89% of SPA examinations (p > 0.05). CONCLUSIONS: As TUC provides significantly lower radiation exposure and less periprocedural complications, it should be the primary bladder access route for VCUG in pediatric male patients.

4.
Cancers (Basel) ; 16(6)2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38539562

RESUMO

This study investigated whether virtual monoenergetic images (VMIs) and iodine mapping based on dual-energy CT (DECT) provide advantages in the assessment of endometrial cancer. A dual-source DECT was performed for primary staging of histologically proven endometrioid adenocarcinoma in 21 women (66.8 ± 12.0 years). In addition to iodine maps, VMIs at 40, 50, 60, 70, and 80 keV were reconstructed from polyenergetic images (PEIs). Objective analysis comprised the measurement of tumor contrast, contrast-to-noise ratio, and normalized iodine concentration (NIC). In addition, three radiologists independently rated tumor conspicuity. The highest tumor contrast (106.6 ± 45.0 HU) and contrast-to-noise ratio (4.4 ± 2.0) was established for VMIs at 40 keV. Tumor contrast in all VMIs ≤ 60 keV was higher than in PEIs (p < 0.001). The NIC of malignant tissue measured in iodine maps was substantially lower compared with a healthy myometrium (0.3 ± 0.1 versus 0.6 ± 0.1 mg/mL; p < 0.001). Tumor conspicuity was highest in 40 keV datasets, whereas no difference was found among PEIs and VMIs at 60 and 70 keV (p ≥ 0.334). Interobserver agreement was good, indicated by an intraclass correlation coefficient of 0.824 (0.772-0.876; p < 0.001). In conclusion, computation of VMIs at 40 keV and color-coded iodine maps aids the assessment of endometroid adenocarcinoma in primary staging.

5.
Acad Radiol ; 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38448327

RESUMO

RATIONALE AND OBJECTIVES: Aiming to offset image quality limitations in radiographs due to superimposition, this study investigates the diagnostic potential of appendicular skeleton tomosynthesis. MATERIALS AND METHODS: Eight cadaveric extremities (four hands and feet) were examined employing the prototypical tomosynthesis mode of a twin robotic X-ray scanner. 12 protocols with varying sweep angles (10, 20 vs. 40°), frame rates (13 vs. 26 fps), and tube voltages (60 vs. 80 kV) were compared to radiographs. Four radiologists separately evaluated cortical and trabecular bone visualization and fracture patterns. Interreader reliability was assessed based on the intraclass correlation coefficient (ICC). RESULTS: Radiation dose in radiography was 0.59 ± 0.20 dGy * cm2 versus 0.11 ± 0.00 to 2.46 ± 0.17 dGy * cm2 for tomosynthesis. Cortical bone display was inferior for radiographs compared to 40° and 20° tomosynthesis. Best results were ascertained for the 80 kV/40°/26 fps protocol. Trabecular bone depiction was also superior in tomosynthesis (p ≤ 0.009) and best with the 80 kV/10°/26 fps setting. Interreader reliability was moderate for cortical bone display (ICC 0.521, 95% confidence interval 0.356-0.641) and good for trabecular bone (0.759, 0.697-0.810). Diagnostic accuracy for articular involvement and multifragment situations was higher in tomosynthesis (93.8-100%/92.2-100%) vs. radiography (85.9%/82.8%.). Diagnostic confidence was also better in tomosynthesis (p ≤ 0.003). CONCLUSION: Compared to radiography, tomosynthesis allows for superior assessability of cortical and trabecular bone and fracture morphology, especially at high framerates. Operating on a multipurpose X-ray system, tomosynthesis of the appendicular skeleton can be performed without additional scanner hardware.

6.
PLoS One ; 19(2): e0297800, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38330071

RESUMO

PURPOSE: The aim of this study was to evaluate the usability of a recently developed extracorporeally-perfused cadaver model for training the angiographic management of acute arterial diseases and periprocedural complications that may occur during endovascular therapy of the lower extremity arterial runoff. MATERIALS AND METHODS: Continuous extracorporeal perfusion was established in three fresh-frozen body donors via inguinal and infragenicular access. Using digital subtraction angiography for guidance, both arterial embolization (e.g., embolization using coils, vascular plugs, particles, and liquid embolic agents) and endovascular recanalization procedures (e.g., manual aspiration or balloon-assisted embolectomy) as well as various embolism protection devices were tested. Furthermore, the management of complications during percutaneous transluminal angioplasty, such as vessel dissection and rupture, were exercised by implantation of endovascular dissection repair system or covered stents. Interventions were performed by two board-certified interventional radiologists and one resident with only limited angiographic experience. RESULTS: Stable extracorporeal perfusion was successfully established on both thighs of all three body donors. Digital subtraction angiography could be performed reliably and resulted in realistic artery depiction. The model allowed for repeatable training of endovascular recanalization and arterial embolization procedures with typical tactile feedback in a controlled environment. Furthermore, the handling of more complex angiographic devices could be exercised. Whereas procedural success was be ascertained for most endovascular interventions, thrombectomies procedures were not feasible in some cases due to the lack of inherent coagulation. CONCLUSION: The presented perfusion model is suitable for practicing time-critical endovascular interventions in the lower extremity runoff under realistic but controlled conditions.


Assuntos
Procedimentos Endovasculares , Doenças Vasculares , Humanos , Procedimentos Endovasculares/métodos , Artérias , Angioplastia/métodos , Stents , Cadáver , Resultado do Tratamento , Estudos Retrospectivos
7.
BMC Med Imaging ; 24(1): 49, 2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38395772

RESUMO

PURPOSE: Unenhanced abdominal CT constitutes the diagnostic standard of care in suspected urolithiasis. Aiming to identify potential for radiation dose reduction in this frequent imaging task, this experimental study compares the effect of spectral shaping and tube voltage modulation on image quality. METHODS: Using a third-generation dual-source CT, eight cadaveric specimens were scanned with varying tube voltage settings with and without tin filter application (Sn 150, Sn 100, 120, 100, and 80 kVp) at three dose levels (3 mGy: standard; 1 mGy: low; 0.5 mGy: ultralow). Image quality was assessed quantitatively by calculation of signal-to-noise ratios (SNR) for various tissues (spleen, kidney, trabecular bone, fat) and subjectively by three independent radiologists based on a seven-point rating scale (7 = excellent; 1 = very poor). RESULTS: Irrespective of dose level, Sn 100 kVp resulted in the highest SNR of all tube voltage settings. In direct comparison to Sn 150 kVp, superior SNR was ascertained for spleen (p ≤ 0.004) and kidney tissue (p ≤ 0.009). In ultralow-dose scans, subjective image quality of Sn 100 kVp (median score 3; interquartile range 3-3) was higher compared with conventional imaging at 120 kVp (2; 2-2), 100 kVp (1; 1-2), and 80 kVp (1; 1-1) (all p < 0.001). Indicated by an intraclass correlation coefficient of 0.945 (95% confidence interval: 0.927-0.960), interrater reliability was excellent. CONCLUSIONS: In abdominal CT with maximised dose reduction, tin prefiltration at 100 kVp allows for superior image quality over Sn 150 kVp and conventional imaging without spectral shaping.


Assuntos
Estanho , Tomografia Computadorizada por Raios X , Humanos , Reprodutibilidade dos Testes , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Abdome/diagnóstico por imagem
8.
Acad Radiol ; 2024 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-38403477

RESUMO

RATIONALE AND OBJECTIVES: This study aims to compare the diagnostic confidence of photon-counting detector CT angiography (PCD-CTA) depending on the used vascular reformatting kernels with digital subtraction angiography (DSA) as diagnostic reference standard in peripheral arterial occlusive disease (PAOD). MATERIAL AND METHODS: In 39 patients, 45 lower extremity PCD-CTA with subsequent DSA were analyzed. Advanced PAOD (Fontaine stage 4) was ascertained in 77.8% of patients. CTA post-processing comprised three vascular kernels (Bv36/48/56). Objective image quality assessment included vessel attenuation, image noise, contrast-to-noise (CNR) and signal-to-noise ratios (SNR). Subjective evaluation of calcium blooming, vessel sharpness, luminal attenuation and image noise was performed by three radiologists. Diagnostic performance and concordance to DSA were assessed. RESULTS: The luminal attenuation remained kernel-independent constant. With sharper kernels, image noise increased substantially, while SNR and CNR decreased. Subjective reduction of calcium blooming and increased vessel sharpness were noted for the sharp Bv56 kernel. While sensitivity in stenosis quantification was comparable between kernels (81.6% vs. 81.5% vs. 81.0%, p = 0.797), specificity increased slightly higher sharpness (71.1% vs. 76.9% vs. 79.6%, p = 0.067). Diagnostic concordance of stenosis ratings compared to DSA increased likewise (Bv36 vs. Bv56, p = 0.002). Severe crural vessel calcifications had no influence on sensitivity, regardless of kernel selection. Contrarily, specificity was substantially worse in severely calcified tibial vessels but could be improved by using the sharp Bv56 kernel (Bv36 vs. Bv56 p = 0.024). Diagnostic confidence was highest for Bv56. CONCLUSION: In lower leg PCD-CTA, sharp convolution kernels increase diagnostic confidence compared to DSA by improved vessel delineation and reduced calcium blooming with acceptable image noise.

9.
Invest Radiol ; 2024 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-38329822

RESUMO

OBJECTIVES: Image acquisition in ultra-high-resolution (UHR) scan mode does not impose a dose penalty in photon-counting CT (PCCT). This study aims to investigate the dose saving potential of using UHR instead of standard-resolution PCCT for lumbar spine imaging. MATERIALS AND METHODS: Eight cadaveric specimens were examined with 7 dose levels (5-35 mGy) each in UHR (120 × 0.2 mm) and standard-resolution acquisition mode (144 × 0.4 mm) on a first-generation PCCT scanner. The UHR images were reconstructed with 3 dedicated bone kernels (Br68 [spatial frequency at 10% of the modulation transfer function 14.5 line pairs/cm], Br76 [21.0], and Br84 [27.9]), standard-resolution images with Br68 and Br76. Using automatic segmentation, contrast-to-noise ratios (CNRs) were established for lumbar vertebrae and psoas muscle tissue. In addition, image quality was assessed subjectively by 19 independent readers (15 radiologists, 4 surgeons) using a browser-based forced choice comparison tool totaling 16,974 performed pairwise tests. Pearson's correlation coefficient ( r ) was used to analyze the relationship between CNR and subjective image quality rankings, and Kendall W was calculated to assess interrater agreement. RESULTS: Irrespective of radiation exposure level, CNR was higher in UHR datasets than in standard-resolution images postprocessed with the same reconstruction parameters. The use of sharper convolution kernels entailed lower CNR but higher subjective image quality depending on radiation dose. Subjective assessment revealed high interrater agreement ( W = 0.86; P < 0.001) with UHR images being preferred by readers in the majority of comparisons on each dose level. Substantial correlation was ascertained between CNR and the subjective image quality ranking (all r 's ≥ 0.95; P < 0.001). CONCLUSIONS: In PCCT of the lumbar spine, UHR mode's smaller pixel size facilitates a considerable CNR increase over standard-resolution imaging, which can either be used for dose reduction or higher spatial resolution depending on the selected convolution kernel.

10.
Magn Reson Imaging ; 107: 100-110, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38246517

RESUMO

INTRODUCTION: With increasing spatial resolution, diffusion-weighted imaging (DWI) may be suitable for morphologic lesion characterization in breast MRI - an area that has traditionally been occupied by dynamic contrast-enhanced imaging (DCE). This investigation compared DWI with b values of 800 and 1600 s/mm2 to DCE for lesion morphology assessment in high-resolution breast MRI at 3 Tesla. MATERIAL AND METHODS: Multiparametric breast MRI was performed in 91 patients with 93 histopathologically proven lesions (31 benign, 62 malignant). Two radiologists independently evaluated three datasets per patient (DWIb800; DWIb1600; DCE) and assessed lesion visibility and BIRADS morphology criteria. Diagnostic accuracy was compared among readers and datasets using Cochran's Q test and pairwise post-hoc McNemar tests. Bland-Altman analyses were conducted for lesion size comparisons. RESULTS: Discrimination of carcinomas was superior compared to benign findings in both DWIb800 and DWIb1600 (p < 0.001) with no b value-dependent difference. Similarly, assessability of mass lesions was better than of non-mass lesions, irrespective of b value (p < 0.001). Intra-reader reliability for the analysis of morphologic BIRADS criteria among DCE and DWI datasets was at least moderate (Fleiss κ≥0.557), while at least substantial inter-reader agreement was ascertained over all assessed categories (κ≥0.776). In pairwise Bland-Altman analyses, the measurement bias between DCE and DWIb800 was 0.7 mm, whereas the difference between DCE and DWIb1600 was 2.8 mm. DWIb1600 allowed for higher specificity than DCE (p = 0.007/0.062). CONCLUSIONS: DWI can be employed for reliable morphologic lesion characterization in high-resolution breast MRI. High b values increase diagnostic specificity, while lesion size assessment is more precise with standard 800 s/mm2 images.


Assuntos
Neoplasias da Mama , Meios de Contraste , Humanos , Feminino , Reprodutibilidade dos Testes , Imagem de Difusão por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/métodos , Mama/diagnóstico por imagem , Mama/patologia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Sensibilidade e Especificidade , Estudos Retrospectivos
11.
Acad Radiol ; 31(4): 1472-1479, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37730493

RESUMO

RATIONALE AND OBJECTIVES: This experimental study investigates the potential of lumbar spine tomosynthesis to offset the traditional limitations of radiographic and computed tomography imaging, that is, superimposition of anatomy and disregard of physiological load-bearing. MATERIALS AND METHODS: A gantry-free twin robotic scanner was used to obtain lateral radiographs and tomosyntheses of the lumbar spine under weight-bearing conditions in eight body donors. Tomosynthesis protocols varied in terms of sweep angle (20 versus 40°), scan time (2.4 versus 4.8 seconds), and framerate (16 versus 30 fps). Image quality and vertebral endplate assessability were evaluated by five radiologists with 4-8 years of skeletal imaging experience. Aiming to identify potential diagnostic deterioration near the scan volume margins, readers additionally determined the craniocaudal extent of clinically acceptable image quality. RESULTS: Tomosynthesis scans effectuated a substantial dose reduction compared to standard radiographs (3.8 ± 0.2 to 15.4 ± 0.8 dGy*cm2 versus 77.7 ± 34.8 dGy*cm2; p ≤ 0.021). Diagnostic image quality and endplate assessability were deemed highest for the 30 fps wide-angle tomosynthesis protocol with good to excellent interrater reliability (intraclass correlation coefficients: 0.846 and 0.946). Accordingly, the craniocaudal extent of acceptable image quality was substantially larger compared to radiography (26.9 versus 18.9 cm; p < 0.001), whereas no significant difference was ascertained for the tomosynthesis protocols with 16 fps (15.3-22.1 cm; all p ≥ 0.058). CONCLUSION: Combining minimal radiation dose with superimposition-free visualization, 30 fps wide-angle tomosynthesis superseded radiography in all evaluated aspects. With superior diagnostic assessability despite significant dose reduction, load-bearing tomosynthesis appears promising as an alternative for first-line lumbar spine imaging in the future.


Assuntos
Vértebras Lombares , Tomografia Computadorizada por Raios X , Humanos , Reprodutibilidade dos Testes , Vértebras Lombares/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Intensificação de Imagem Radiográfica/métodos
12.
Invest Radiol ; 59(4): 293-297, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-37552040

RESUMO

OBJECTIVES: The aim of this study was to investigate potential benefits of ultra-high resolution (UHR) over standard resolution scan mode in ultra-low dose photon-counting detector CT (PCD-CT) of the lung. MATERIALS AND METHODS: Six cadaveric specimens were examined with 5 dose settings using tin prefiltration, each in UHR (120 × 0.2 mm) and standard mode (144 × 0.4 mm), on a first-generation PCD-CT scanner. Image quality was evaluated quantitatively by noise comparisons in the trachea and both main bronchi. In addition, 16 readers (14 radiologists and 2 internal medicine physicians) independently completed a browser-based pairwise forced-choice comparison task for assessment of subjective image quality. The Kendall rank coefficient ( W ) was calculated to assess interrater agreement, and Pearson's correlation coefficient ( r ) was used to analyze the relationship between noise measurements and image quality rankings. RESULTS: Across all dose levels, image noise in UHR mode was lower than in standard mode for scan protocols matched by CTDI vol ( P < 0.001). UHR examinations exhibited noise levels comparable to the next higher dose setting in standard mode ( P ≥ 0.275). Subjective ranking of protocols based on 5760 pairwise tests showed high interrater agreement ( W = 0.99; P ≤ 0.001) with UHR images being preferred by readers in the majority of comparisons. Irrespective of scan mode, a substantial indirect correlation was observed between image noise and subjective image quality ranking ( r = -0.97; P ≤ 0.001). CONCLUSIONS: In PCD-CT of the lung, UHR scan mode reduces image noise considerably over standard resolution acquisition. Originating from the smaller detector element size in fan direction, the small pixel effect allows for superior image quality in ultra-low dose examinations with considerable potential for radiation dose reduction.


Assuntos
Fótons , Tomografia Computadorizada por Raios X , Humanos , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos , Pulmão/diagnóstico por imagem , Tórax
13.
Eur J Radiol ; 170: 111209, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37992609

RESUMO

PURPOSE: To investigate the metal artifact suppression potential of combining tin prefiltration and virtual monoenergetic imaging (VMI) for osseous microarchitecture depiction in ultra-high-resolution (UHR) photon-counting CT (PCCT) of the lower extremity. METHOD: Derived from tin-filtered UHR scans at 140 kVp, polychromatic datasets (T3D) and VMI reconstructions at 70, 110, 150, and 190 keV were compared in 117 patients with lower extremity metal implants (53 female; 62.1 ± 18.0 years). Three implant groups were investigated (total arthroplasty [n = 48], osteosynthetic material [n = 43], and external fixation [n = 26]). Image quality was assessed with regions of interest placed in the most pronounced artifacts and adjacent soft tissue, measuring the respective attenuation. Additionally, artifact extent, bone-metal interface interpretability and overall image quality were independently evaluated by three radiologists. RESULTS: Artifact reduction was superior with increasing keV level of VMI. While T3D was superior to VMI70keV (p ≥ 0.117), artifacts were more severe in T3D than in VMI ≥ 110 keV (all p ≤ 0.036). Image noise was highest for VMI70keV (all p < 0.001) and lowest for VMI110keV with comparable results for VMI110keV - VMI190keV. Subjective image quality regarding artifacts was superior for VMI ≥ 110 keV (all p ≤ 0.042) and comparable for VMI110keV - VMI190keV. Bone-metal interface interpretability was superior for VMI110keV (all p ≤ 0.001), while T3D, VMI150keV and VMI190keV were comparable. Overall image quality was deemed best for VMI110keV and VMI150keV. Interreader reliability was good in all cases (ICC ≥ 0.833). CONCLUSIONS: Tin-filtered UHR-PCCT scans of the lower extremity combined with VMI reconstructions allow for efficient artifact reduction in the vicinity of bone-metal interfaces.


Assuntos
Estanho , Tomografia Computadorizada por Raios X , Humanos , Feminino , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos , Próteses e Implantes , Processamento de Imagem Assistida por Computador/métodos , Metais , Artefatos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Razão Sinal-Ruído , Estudos Retrospectivos
14.
Invest Radiol ; 59(4): 320-327, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-37812470

RESUMO

BACKGROUND AND AIMS: This study aims to compare the performance of first-generation dual-source photon-counting detector computed tomography (PCD-CT) to third-generation dual-source energy-integrating detector (EID-CT) regarding stent imaging in the femoral arterial runoff. METHODS: Continuous extracorporeal perfusion was established in 1 human cadaver using an inguinal and infragenicular access and peristaltic pump. Seven peripheral stents were implanted into both superior femoral arteries by means of percutaneous angioplasty. Radiation dose-equivalent CT angiographies (high-/medium-/low-dose: 10/5/3 mGy) with constant tube voltage of 120 kVp, matching iterative reconstruction algorithm levels, and convolution kernels were used both with PCD-CT and EID-CT. In-stent lumen visibility, luminal and in-stent attenuation as well as contrast-to-noise ratio (CNR) were assessed via region of interest and diameter measurements. Results were compared using analyses of variance and regression analyses. RESULTS: Maximum in-stent lumen visibility achieved with PCD-CT was 94.48% ± 2.62%. The PCD-CT protocol with the lowest lumen visibility (BV40: 78.93% ± 4.67%) performed equal to the EID-CT protocol with the best lumen visibility (BV59: 79.49% ± 2.64%, P > 0.999). Photon-counting detector CT yielded superior CNR compared with EID-CT regardless of kernel and dose level ( P < 0.001). Maximum CNR was 48.8 ± 17.4 in PCD-CT versus 31.28 ± 5.7 in EID-CT (both BV40, high-dose). The theoretical dose reduction potential of PCD-CT over EID-CT was established at 88% (BV40), 83% (BV48/49), and 73% (BV59/60), respectively. In-stent attenuation was not significantly different from luminal attenuation outside stents in any protocol. CONCLUSIONS: With superior lumen visibility and CNR, PCD-CT allowed for noticeable dose reduction over EID-CT while maintaining image quality in a continuously perfused human cadaveric model.


Assuntos
Fótons , Tomografia Computadorizada por Raios X , Humanos , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos , Stents , Cadáver
15.
Diagnostics (Basel) ; 13(24)2023 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-38132229

RESUMO

This retrospective study aims to provide an intra-individual comparison of aortic CT angiographies (CTAs) using first-generation photon-counting-detector CT (PCD-CT) and third-generation energy-integrating-detector CT (EID-CT). High-pitch CTAs were performed with both scanners and equal contrast-agent protocols. EID-CT employed automatic tube voltage selection (90/100 kVp) with reference tube current of 434/350 mAs, whereas multi-energy PCD-CT scans were generated with fixed tube voltage (120 kVp), image quality level of 64, and reconstructed as 55 keV monoenergetic images. For image quality assessment, contrast-to-noise ratios (CNRs) were calculated, and subjective evaluation (overall quality, luminal contrast, vessel sharpness, blooming, and beam hardening) was performed independently by three radiologists. Fifty-seven patients (12 women, 45 men) were included with a median interval between examinations of 12.7 months (interquartile range 11.1 months). Using manufacturer-recommended scan protocols resulted in a substantially lower radiation dose in PCD-CT (size-specific dose estimate: 4.88 ± 0.48 versus 6.28 ± 0.50 mGy, p < 0.001), while CNR was approximately 50% higher (41.11 ± 8.68 versus 27.05 ± 6.73, p < 0.001). Overall image quality and luminal contrast were deemed superior in PCD-CT (p < 0.001). Notably, EID-CT allowed for comparable vessel sharpness (p = 0.439) and less pronounced blooming and beam hardening (p < 0.001). Inter-rater agreement was good to excellent (0.58-0.87). Concluding, aortic PCD-CTAs facilitate increased image quality with significantly lower radiation dose compared to EID-CTAs.

16.
Eur Radiol Exp ; 7(1): 83, 2023 12 18.
Artigo em Inglês | MEDLINE | ID: mdl-38110729

RESUMO

BACKGROUND: With the emergence of photon-counting CT, ultrahigh-resolution (UHR) imaging can be performed without dose penalty. This study aims to directly compare the image quality of UHR and standard resolution (SR) scan mode in femoral artery angiographies. METHODS: After establishing continuous extracorporeal perfusion in four fresh-frozen cadaveric specimens, photon-counting CT angiographies were performed with a radiation dose of 5 mGy and tube voltage of 120 kV in both SR and UHR mode. Images were reconstructed with dedicated convolution kernels (soft: Body-vascular (Bv)48; sharp: Bv60; ultrasharp: Bv76). Six radiologists evaluated the image quality by means of a pairwise forced-choice comparison tool. Kendall's concordance coefficient (W) was calculated to quantify interrater agreement. Image quality was further assessed by measuring intraluminal attenuation and image noise as well as by calculating signal-to-noise ratio (SNR) and contrast-to-noise ratios (CNR). RESULTS: UHR yielded lower noise than SR for identical reconstructions with kernels ≥ Bv60 (p < 0.001). UHR scans exhibited lower intraluminal attenuation compared to SR (Bv60: 406.4 ± 25.1 versus 418.1 ± 30.1 HU; p < 0.001). Irrespective of scan mode, SNR and CNR decreased while noise increased with sharper kernels but UHR scans were objectively superior to SR nonetheless (Bv60: SNR 25.9 ± 6.4 versus 20.9 ± 5.3; CNR 22.7 ± 5.8 versus 18.4 ± 4.8; p < 0.001). Notably, UHR scans were preferred in subjective assessment when images were reconstructed with the ultrasharp Bv76 kernel, whereas SR was rated superior for Bv60. Interrater agreement was high (W = 0.935). CONCLUSIONS: Combinations of UHR scan mode and ultrasharp convolution kernel are able to exploit the full image quality potential in photon-counting CT angiography of the femoral arteries. RELEVANCE STATEMENT: The UHR scan mode offers improved image quality and may increase diagnostic accuracy in CT angiography of the peripheral arterial runoff when optimized reconstruction parameters are chosen. KEY POINTS: • UHR photon-counting CT improves image quality in combination with ultrasharp convolution kernels. • UHR datasets display lower image noise compared with identically reconstructed standard resolution scans. • Scans in UHR mode show decreased intraluminal attenuation compared with standard resolution imaging.


Assuntos
Angiografia por Tomografia Computadorizada , Artéria Femoral , Humanos , Angiografia por Tomografia Computadorizada/métodos , Artéria Femoral/diagnóstico por imagem , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos , Angiografia
17.
J Magn Reson Imaging ; 2023 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-37974498

RESUMO

BACKGROUND: For time-consuming diffusion-weighted imaging (DWI) of the breast, deep learning-based imaging acceleration appears particularly promising. PURPOSE: To investigate a combined k-space-to-image reconstruction approach for scan time reduction and improved spatial resolution in breast DWI. STUDY TYPE: Retrospective. POPULATION: 133 women (age 49.7 ± 12.1 years) underwent multiparametric breast MRI. FIELD STRENGTH/SEQUENCE: 3.0T/T2 turbo spin echo, T1 3D gradient echo, DWI (800 and 1600 sec/mm2 ). ASSESSMENT: DWI data were retrospectively processed using deep learning-based k-space-to-image reconstruction (DL-DWI) and an additional super-resolution algorithm (SRDL-DWI). In addition to signal-to-noise ratio and apparent diffusion coefficient (ADC) comparisons among standard, DL- and SRDL-DWI, a range of quantitative similarity (e.g., structural similarity index [SSIM]) and error metrics (e.g., normalized root mean square error [NRMSE], symmetric mean absolute percent error [SMAPE], log accuracy error [LOGAC]) was calculated to analyze structural variations. Subjective image evaluation was performed independently by three radiologists on a seven-point rating scale. STATISTICAL TESTS: Friedman's rank-based analysis of variance with Bonferroni-corrected pairwise post-hoc tests. P < 0.05 was considered significant. RESULTS: Both DL- and SRDL-DWI allowed for a 39% reduction in simulated scan time over standard DWI (5 vs. 3 minutes). The highest image quality ratings were assigned to SRDL-DWI with good interreader agreement (ICC 0.834; 95% confidence interval 0.818-0.848). Irrespective of b-value, both standard and DL-DWI produced superior SNR compared to SRDL-DWI. ADC values were slightly higher in SRDL-DWI (+0.5%) and DL-DWI (+3.4%) than in standard DWI. Structural similarity was excellent between DL-/SRDL-DWI and standard DWI for either b value (SSIM ≥ 0.86). Calculation of error metrics (NRMSE ≤ 0.05, SMAPE ≤ 0.02, and LOGAC ≤ 0.04) supported the assumption of low voxel-wise error. DATA CONCLUSION: Deep learning-based k-space-to-image reconstruction reduces simulated scan time of breast DWI by 39% without influencing structural similarity. Additionally, super-resolution interpolation allows for substantial improvement of subjective image quality. EVIDENCE LEVEL: 4 TECHNICAL EFFICACY: Stage 1.

18.
GMS J Med Educ ; 40(5): Doc59, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37881519

RESUMO

Aims: Tablets are being adopted as teaching medium in medical education more frequently. Here we compared two teaching formats in a radiology seminar using a tablet-based student-centred approach guided by teachers and traditional presentation-based, teacher-centred instruction. The aim was to investigate the effects on academic performance, estimated learning gain, didactic quality, as well as how teacher charisma and student digital affinity influence these elements. Methods: Data from 366 students were collected. Student digital affinity, didactic quality of, and overall satisfaction with the seminars were rated for each teaching format over three semesters, whereby in the last semester, students additionally estimated their learning gain, took a knowledge and image interpretation test, and rated teacher charisma. Results: The tablet-based seminars yielded significantly higher ratings for didactic quality and overall satisfaction. However, the presentation-based seminars proved superior with respect to academic performance as well as estimated learning gain. When employing tablets, teacher charisma correlated with estimated learning gain, and digital affinity affected didactic quality. Additionally, good seminar organization, comprehensible learning objectives, and optimal variation of learning activities were identified as important factors. Conclusion: This study suggests a complex interplay of various factors concerning teachers, students, and didactics that can be assessed and improved to assure the successful curricular implementation of tablets. Of note, tablet integration and thereby active engagement of students with imaging analysis skills does not automatically result in greater declarative knowledge. Nevertheless, understanding the complexities of structuring and delivering tablet-based, teacher-guided instruction is essential to creating meaningful educational experiences.


Assuntos
Pessoal de Educação , Radiologia , Estudantes de Medicina , Humanos , Avaliação Educacional/métodos , Aprendizagem , Radiologia/educação
19.
Eur J Radiol ; 169: 111157, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37871356

RESUMO

PURPOSE: Since organ-based tube current modulation (OBTCM) and tin prefiltration are limited on their own in lowering the dose of lung CT examinations, this experimental study was designed to investigate whether combinations with anterior patient shielding can increase the dose reduction potential. MATERIAL AND METHODS: Three pairs of scan protocols without/with breast shield (P1/P2: standard 120kVp, P3/P4: OBTCM at 100 kVp, P5/P6: Sn 100 kVp) were employed for radiation exposure and image quality comparisons on an anthropomorphic Alderson-Rando phantom. Equivalent doses were measured in eleven sites via thermoluminescent dosimetry and the effective dose was obtained by summation of the weighted organ doses. Dose-weighted contrast-to-noise ratios (CNRD) were calculated and four radiologists independently assessed the quality of images generated with each protocol. RESULTS: While no significant difference was determined between standard and OBTCM protocols regardless of breast shield (p ≥ 0.068), equivalent doses with spectral shaping were substantially lower (p ≤ 0.003). The highest effective dose was ascertained for standard scans (P1/P2: 7.3/6.8 mSv) with a dose reduction of 8.0 % via breast shielding. The use of a bismuth shield was more beneficial in OBTCM (P3/P4: 6.6/5.3 mSv) and spectral shaping (P5/P6: 0.7/0.6 mSv), reducing the effective dose by 19.8 % and 13.9 %, respectively. Subjective assessment favoured standard protocol P1 over tin prefiltration low-dose scans (p ≤ 0.032), however, no scan protocol entailed diagnostically insufficient image quality. CONCLUSIONS: Whereas breast shielding is particularly beneficial in combination with OBTCM, spectral shaping via tin prefiltration facilitates the most pronounced dose reduction in lung CT imaging with acceptable image quality.


Assuntos
Bismuto , Estanho , Humanos , Doses de Radiação , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos , Pulmão/diagnóstico por imagem
20.
Eur J Radiol ; 167: 111055, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37632998

RESUMO

PURPOSE: Leg torsion analysis can provide valuable information in symptomatic patients after total knee arthroplasty. However, extensive beam-hardening and photon-starvation artifacts limit diagnostic assessability and dose reduction potential. For this study, we investigated the reproducibility of rotational measurements in ultra-low-dose photon-counting CT with spectral shaping via tin prefiltration. MATERIAL AND METHODS: Employing a first-generation photon-counting CT, eight cadaveric specimens were examined with an established three-level scan protocol (hip: Sn 140, knee: Sn 100, ankle: Sn 100 kVp). In three body donors with unilateral knee endoprostheses, additional modified settings were applied (Sn 140 kVp at knee level). Protocols were executed with three dose levels (hip-knee-ankle, high-quality: 5.0-3.0-2.0 mGy, low-dose: 0.80-0.30-0.26 mGy, ultra-low-dose: 0.25-0.06-0.06 mGy). Six radiologists performed torsion analyses, additionally reporting their diagnostic confidence. Intraclass correlation coefficients (ICC) were calculated to assess interrater reliability. RESULTS: No significant differences were ascertained for femoral (p = 0.330), tibial (p = 0.177), and overall leg rotation measurements (p = 0.358) among high-quality, low-dose, and ultra-low-dose protocols. Interrater reliability was excellent for torsion of the femur (ICC 0.915, 95% confidence interval 0.871-0.947), tibia (0.960, 0.938-0.976), and overall leg (0.967, 0.945-0.981). In specimens with total knee endoprostheses, absolute rotational measurements were unaffected by dose level and tube voltage despite superior diagnostic confidence on the ipsilateral and contralateral sides with modified settings (p < 0.001). CONCLUSIONS: Combining the advantages of photon-counting CT and spectral shaping, reliable leg torsion analyses are feasible with ultra-low radiation exposure even in the presence of total knee endoprostheses.


Assuntos
Extremidade Inferior , Tomografia Computadorizada por Raios X , Humanos , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos , Articulação do Joelho/cirurgia , Próteses e Implantes