Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Angew Chem Int Ed Engl ; 63(4): e202314528, 2024 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-38037863

RESUMO

Porous solids often contain complex pore networks with pores of various sizes. Tracking individual fluorescent probes as they diffuse through porous materials can be used to characterize pore networks at tens of nanometers resolution. However, understanding the motion behavior of fluorescent probes in confinement is crucial to reliably derive pore network properties. Here, we introduce well-defined lithography-made model pores developed to study probe behavior in confinement. We investigated the influence of probe-host interactions on diffusion and trapping of confined single-emitter quantum-dot probes. Using the pH-responsiveness of the probes, we were able to largely suppress trapping at the pore walls. This enabled us to define experimental conditions for mapping of the accessible pore space of a one-dimensional pore array as well as a real-life polymerization-catalyst-support particle.

2.
Small ; 19(49): e2302939, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37496086

RESUMO

Microbubble generation and manipulation play critical roles in diverse applications such as microfluidic mixing, pumping, and microrobot propulsion. However, existing methods are typically limited to lateral movements on customized substrates or rely on specific liquids with particular properties or designed concentration gradients, thereby hindering their practical applications. To address this challenge, this paper presents a method that enables robust vertical manipulation of microbubbles. By focusing a resonant laser on hydrophilic silica-coated gold nanoparticle arrays immersed in water, plasmonic microbubbles are generated and detach from the substrates immediately upon cessation of laser irradiation. Using simple laser pulse control, it can achieve an adjustable size and frequency of bubble bouncing, which is governed by the movement of the three-phase contact line during surface wetting. Furthermore, it demonstrates that rising bubbles can be pulled back by laser irradiation induced thermal Marangoni flow, which is verified by particle image velocimetry measurements and numerical simulations. This study provides novel insights into flexible bubble manipulation and integration in microfluidics, with significant implications for various applications including mixing, drug delivery, and the development of soft actuators.

3.
Microsyst Nanoeng ; 9: 39, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37007606

RESUMO

The particles of heterogeneous catalysts differ greatly in size, morphology, and most importantly, in activity. Studying these catalyst particles in batch typically results in ensemble averages, without any information at the level of individual catalyst particles. To date, the study of individual catalyst particles has been rewarding but is still rather slow and often cumbersome1. Furthermore, these valuable in-depth studies at the single particle level lack statistical relevance. Here, we report the development of a droplet microreactor for high-throughput fluorescence-based measurements of the acidities of individual particles in fluid catalytic cracking (FCC) equilibrium catalysts (ECAT). This method combines systematic screening of single catalyst particles with statistical relevance. An oligomerization reaction of 4-methoxystyrene, catalyzed by the Brønsted acid sites inside the zeolite domains of the ECAT particles, was performed on-chip at 95 °C. The fluorescence signal generated by the reaction products inside the ECAT particles was detected near the outlet of the microreactor. The high-throughput acidity screening platform was capable of detecting ~1000 catalyst particles at a rate of 1 catalyst particle every 2.4 s. The number of detected catalyst particles was representative of the overall catalyst particle population with a confidence level of 95%. The measured fluorescence intensities showed a clear acidity distribution among the catalyst particles, with the majority (96.1%) showing acidity levels belonging to old, deactivated catalyst particles and a minority (3.9%) exhibiting high acidity levels. The latter are potentially of high interest, as they reveal interesting new physicochemical properties indicating why the particles were still highly acidic and reactive.

4.
Lab Chip ; 20(21): 3938-3947, 2020 11 07.
Artigo em Inglês | MEDLINE | ID: mdl-32975255

RESUMO

Chromatographic columns are suffering from Taylor-Aris dispersion, especially for slowly diffusing molecules such as proteins. Since downscaling the channel size to reduce Taylor-Aris dispersion meets fundamental pressure limitations, new strategies are needed to further improve chromatography beyond its current limits. In this work we demonstrate a method to reduce Taylor-Aris dispersion by lateral mixing in a newly designed silicon AC-electroosmotic flow mixer. We obtained a reduction in κaris by a factor of three in a 40 µm × 20 µm microchannel, corresponding to a plate height gain of 2 to 3 under unretained conditions at low to high Pe values. We also demonstrate an improvement of a reverse-phase chromatographic separation of coumarins.

5.
J Phys Chem C Nanomater Interfaces ; 123(38): 23586-23593, 2019 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-31583035

RESUMO

Under continuous laser irradiation, noble metal nanoparticles immersed in water can quickly heat up, leading to the nucleation of so-called plasmonic bubbles. In this work, we want to further understand the bubble nucleation and growth mechanism. In particular, we quantitatively study the effect of the amount of dissolved air on the bubble nucleation and growth dynamics, both for the initial giant bubble, which forms shortly after switching on the laser and is mainly composed of vapor, and for the final life phase of the bubble, during which it mainly contains air expelled from water. We found that the bubble nucleation temperature depends on the gas concentration: the higher the gas concentration, the lower the bubble nucleation temperature. Also, the long-term diffusion-dominated bubble growth is governed by the gas concentration. The radius of the bubbles grows as R(t) ∝ t 1/3 for air-equilibrated and air-oversaturated water. In contrast, in partially degassed water, the growth is much slower since, even for the highest temperature we achieve, the water remains undersaturated.

6.
Nanoscale ; 11(25): 12152-12160, 2019 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-31194202

RESUMO

We report a robust and high-yield fabrication method for wafer-scale patterning of high-quality arrays of dense gold nanogaps, combining displacement Talbot lithography based shrink-etching with dry etching, wet etching, and thin film deposition techniques. By using the self-sharpening of <111>-oriented silicon crystal planes during the wet etching process, silicon structures with extremely smooth nanogaps are obtained. Subsequent conformal deposition of a silicon nitride layer and a gold layer results in dense arrays of narrow gold nanogaps. Using this method, we successfully fabricate high-quality Au nanogaps down to 10 nm over full wafer areas. Moreover, the gap spacing can be tuned by changing the thickness of deposited Au layers. Since the roughness of the template is minimized by the crystallographic etching of silicon, the roughness of the gold nanogaps depends almost exclusively on the roughness of the sputtered gold layers. Additionally, our fabricated Au nanogaps show a significant enhancement of surface-enhanced Raman scattering (SERS) signals of benzenethiol molecules chemisorbed on the structure surface, at an average enhancement factor up to 1.5 × 106.

7.
Lab Chip ; 19(8): 1332-1343, 2019 04 09.
Artigo em Inglês | MEDLINE | ID: mdl-30869670

RESUMO

Measuring biomolecule concentrations in the brain of living animals, in real time, is a challenging task, especially when detailed information at high temporal resolution is also required. Traditionally, microdialysis probes are used that generally have sampling areas in the order of about 1 mm2, and provide information on concentrations with a temporal resolution of at least several minutes. In this paper, we present a novel miniaturized push-pull perfusion sampling probe that uses an array of small 3 µm-wide sampling channels to sample neurotransmitters at a typical recovery rate of 61%, with a reduced risk of clogging. The added feature to segment the dialysate inside the probe into small water-in-decane droplets enables the detection of concentrations with a temporal resolution of a few seconds. Here we used the probe for in vivo recordings of neurotransmitter glutamate released upon electrical stimulation in the brain of a mouse to demonstrate the feasibility of the probe for real-time neurochemical brain analysis.


Assuntos
Dispositivos Lab-On-A-Chip , Neurotransmissores/metabolismo , Animais , Desenho de Equipamento , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Fenômenos Ópticos
8.
Lab Chip ; 19(6): 1054-1059, 2019 03 13.
Artigo em Inglês | MEDLINE | ID: mdl-30768116

RESUMO

In this work, a new method to track particles in microfluidic channels is presented. Particle position tracking in microfluidic systems is crucial to characterize sorting systems or to improve the analysis of cells in impedance flow cytometry studies. By developing an electric field gradient in a two parallel electrode array the position of the particles can be tracked in one axis by impedance analysis. This method can track the particle's position at lower frequencies and measure the conductivity of the system at higher frequencies. A 3-D simulation was performed showing particle position detection and conductivity analysis. To experimentally validate the technique, a microfluidic chip that develops a gradient in the electric field was fabricated and used to detect the position of polystyrene particles in one axis and measure their conductivity at low and high frequencies, respectively.

9.
Electrophoresis ; 39(3): 496-503, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29193178

RESUMO

Combining high-resolution imaging and electrophysiological recordings is key for various types of experimentation on lipid bilayers and ion channels. Here, we propose an integrated biosensing platform consisting of a microfluidic cartridge and a dedicated chip-holder to conduct such dual measurements on suspended lipid bilayers, in a user-friendly manner. To illustrate the potential of the integrated platform, we characterize lipid bilayers in terms of thickness and fluidity while simultaneously monitoring single ion channel currents. For that purpose, POPC lipid bilayers are supplemented with a fluorescently-tagged phospholipid (NBD-PE, 1% mol) for Fluorescence Recovery After Photobleaching (FRAP) measurements and a model ion channel (gramicidin, 1 nM). These combined measurements reveal that NBD-PE has no effect on the lipid bilayer thickness while gramicidin induces thinning of the membrane. Furthermore, the presence of gramicidin does not alter the lipid bilayer fluidity. Surprisingly, in lipid bilayers supplemented with both probes, a reduction in gramicidin open probability and lifetime is observed compared to lipid bilayers with gramicidin only, suggesting an influence of NBD-PE on the gramicidin ion function. Altogether, our proposed microfluidic biosensing platform in combination with the herein presented multi-parametric measurement scheme paves the way to explore the interdependent relationship between lipid bilayer properties and ion channel function.


Assuntos
Técnicas Biossensoriais/instrumentação , Canais Iônicos/química , Bicamadas Lipídicas/química , Técnicas Analíticas Microfluídicas/instrumentação , Microscopia Confocal/instrumentação , Corantes Fluorescentes/química , Gramicidina/química , Dispositivos Lab-On-A-Chip , Fosfatidilcolinas/química , Fosfatidiletanolaminas/química
10.
Microsyst Nanoeng ; 3: 17001, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-31057856

RESUMO

A new approach is presented for preparative, continuous flow fractionation of sub-10-kbp DNA fragments, which exploits the variation in the field-dependent mobility of the DNA molecules based on their length. Orthogonally pulsed electric fields of significantly different magnitudes are applied to a microchip filled with a sieving matrix of 1.2% agarose gel. Using this method, we demonstrate a high-resolution separation of 0.5, 1, 2, 5, and 10 kbp DNA fragments within 2 min. During the separation, DNA fragments are also purified from other ionic species. Preparative fractionation of sub-10-kbp DNA molecules plays an important role in second-generation sequencing. The presented device performs rapid high-resolution fractionation and it can be reliably manufactured with simple microfabrication procedures.

11.
Fertil Steril ; 106(3): 773-780.e6, 2016 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-27281780

RESUMO

OBJECTIVE: To study single sperm boar motility using electrical impedance measurements in a microfluidic system. DESIGN: Comparison of the optical data and electrical impedance data. SETTING: Research laboratory at a university. ANIMAL(S): Boar semen sample were used. INTERVENTION(S): A microfluidic system is developed that is able to spatially confine single boar sperm cells and allows noninvasive analysis of their motility on the single cell level. Using this system, the single sperm motility was affected by changing the temperature or adding chemical stimuli (caffeine). The retrieved electrical impedance and video data were processed using Matlab. MAIN OUTCOME MEASURE(S): The sperm beat frequency and amplitude determined from the electrical impedance and video data. RESULT(S): The electrically measured sperm beat frequency was verified by optical analysis and in correspondence. Furthermore the microfluidic platform allowed single sperm analysis by altering the sperm by temperature and chemical stimuli. CONCLUSION(S): This platform could be exploited as a potential tool to study sperm cells on the single cell level and to perform advanced sperm selection for intracytoplasmic sperm injection (ICSI) applications.


Assuntos
Técnicas Analíticas Microfluídicas , Análise do Sêmen/métodos , Motilidade dos Espermatozoides , Espermatozoides/fisiologia , Animais , Cafeína/farmacologia , Impedância Elétrica , Dispositivos Lab-On-A-Chip , Masculino , Técnicas Analíticas Microfluídicas/instrumentação , Reprodutibilidade dos Testes , Análise do Sêmen/instrumentação , Motilidade dos Espermatozoides/efeitos dos fármacos , Espermatozoides/efeitos dos fármacos , Sus scrofa , Temperatura , Fatores de Tempo , Gravação em Vídeo
12.
Biomacromolecules ; 16(12): 3802-10, 2015 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-26558488

RESUMO

To date, optical lithography has been extensively used for in situ patterning of hydrogel structures in a scale range from hundreds of microns to a few millimeters. The two main limitations which prevent smaller feature sizes of hydrogel structures are (1) the upper glass layer of a microchip maintains a large spacing (typically 525 µm) between the photomask and hydrogel precursor, leading to diffraction of UV light at the edges of mask patterns, (2) diffusion of free radicals and monomers results in irregular polymerization near the illumination interface. In this work, we present a simple approach to enable the use of optical lithography to fabricate hydrogel arrays with a minimum feature size of 4 µm inside closed microchips. To achieve this, we combined two different techniques. First, the upper glass layer of the microchip was thinned by mechanical polishing to reduce the spacing between the photomask and hydrogel precursor, and thereby the diffraction of UV light at the edges of mask patterns. The polishing process reduces the upper layer thickness from ∼525 to ∼100 µm, and the mean surface roughness from 20 to 3 nm. Second, we developed an intermittent illumination technique consisting of short illumination periods followed by relatively longer dark periods, which decrease the diffusion of monomers. Combination of these two methods allows for fabrication of 0.4 × 10(6) sub-10 µm sized hydrogel patterns over large areas (cm(2)) with high reproducibility (∼98.5% patterning success). The patterning method is tested with two different types of photopolymerizing hydrogels: polyacrylamide and polyethylene glycol diacrylate. This method enables in situ fabrication of well-defined hydrogel patterns and presents a simple approach to fabricate 3-D hydrogel matrices for biomolecule separation, biosensing, tissue engineering, and immobilized protein microarray applications.


Assuntos
Resinas Acrílicas/química , Hidrogéis/química , Microtecnologia/métodos , Polietilenoglicóis/química , Técnicas Biossensoriais , Radicais Livres/química , Vidro/química , Microtecnologia/instrumentação , Processos Fotoquímicos , Análise Serial de Proteínas , Reprodutibilidade dos Testes , Raios Ultravioleta
13.
Lab Chip ; 15(3): 664-7, 2015 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-25512130

RESUMO

Capillary barriers provide a simple and elegant means for autonomous fluid-flow control in microfluidic systems. In this work, we report on the fabrication of periodic hydrogel microarrays in closed microfluidic systems using non-fluorescent capillary barriers. This design strategy enables the fabrication of picoliter-volume patterns of photopolymerized and thermo-gelling hydrogels without any defects and distortions.


Assuntos
Hidrogel de Polietilenoglicol-Dimetacrilato/química , Dispositivos Lab-On-A-Chip , Eletroforese Capilar/instrumentação , Desenho de Equipamento , Processos Fotoquímicos , Polimerização , Temperatura
14.
Lab Chip ; 14(23): 4461-4, 2014 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-25284632

RESUMO

We report a wafer-scale fabrication process for the production of glass-FEP-glass microdevices using UV-curable adhesive (NOA81) as gluing material, which is applied using a novel "spin & roll" approach. Devices are characterized for the uniformity of the gluing layer, presence of glue in the microchannels, and alignment precision. Experiments on lipid bilayers with electrophysiological recordings using a model pore-forming polypeptide are demonstrated.


Assuntos
Vidro/química , Bicamadas Lipídicas/química , Técnicas Analíticas Microfluídicas/instrumentação , Politetrafluoretileno/análogos & derivados , Adesivos , Eletrofisiologia , Desenho de Equipamento , Politetrafluoretileno/química
15.
Small ; 9(7): 1076-85, 2013 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-23139010

RESUMO

A microfluidic platform is reported for various experimentation schemes on cell membrane models and membrane proteins using a combination of electrical and optical measurements, including confocal microscopy. Bilayer lipid membranes (BLMs) are prepared in the device upon spontaneous and instantaneous thinning of the lipid solution in a 100-µm dry-etched aperture in a 12.5-µm thick Teflon foil. Using this quasi-automated approach, a remarkable 100% membrane formation yield is reached (including reflushing in 4% of the cases), and BLMs are stable for up to 36 h. Furthermore, the potential of this platform is demonstrated for (i) the in-depth characterization of BLMs comprising both synthetic and natural lipids (1,2-diphytanoyl-sn-glycero-3-phosphocholine (DPhPC) and L-α-phosphatidylcholine (L-α-PC)/cholesterol, respectively) in terms of seal resistance, capacitance, surface area, specific capacitance, and membrane hydrophobic thickness; (ii) confocal microscopy imaging of phase separation in sphingomyelin/L-α-PC/cholesterol ternary membranes; (iii) electrical measurements of individual nanopores (α-hemolysin, gramicidin); and (iv) indirect assessment of the alteration of membrane properties upon exposure to chemical stimuli using the natural nanopore gramicidin as a sensor.


Assuntos
Bicamadas Lipídicas/química , Membranas Artificiais , Microfluídica/métodos , Colesterol/química , Microscopia Confocal , Fosfatidilcolinas/química
16.
Nanotechnology ; 22(49): 494013, 2011 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-22101733

RESUMO

We report a high-throughput clog-free microfluidic deoxyribonucleic acid (DNA) fragmentation chip that is based on hydrodynamic shearing. Salmon sperm DNA has been reproducibly fragmented down to ∼ 5k bp fragment lengths by applying low hydraulic pressures (≤1 bar) across micromachined constrictions positioned in larger microfluidic channels that create point-sink flow with large velocity gradients near the constriction entrance. Long constrictions (100 µm) produce shorter fragment lengths compared to shorter constrictions (10 µm), while increasing the hydrodynamic pressure requirement. Sample recirculation (10 ×) in short constrictions reduces the mean fragment length and fragment length variation, and improves yield compared to single-pass experiments without increasing the hydrodynamic pressure.


Assuntos
Fragmentação do DNA , DNA/genética , Genômica/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Análise de Sequência com Séries de Oligonucleotídeos/instrumentação , Animais , DNA/análise , Desenho de Equipamento , Hidrodinâmica , Salmão
17.
Electrophoresis ; 32(18): 2402-9, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21922490

RESUMO

The electrokinetic transport behavior of λ-DNA (48 kbp) in 20 nm-high fused-silica nanoslits in the presence of short-chain PVP is investigated. Mobility and video data show a number of phenomena that are typical of DNA transport through gels or polymer solutions, thus indicative of rigid migration obstacles in the DNA pathway. Calculations show that a several nanometer thin layer of wall-adsorbed PVP ('nano-gel') can provide such a rigid obstacle matrix to the DNA. Such ultrathin wall-adsorbed polymer layers represent a new type of matrix for electrokinetic DNA separation.


Assuntos
DNA Viral/química , Eletroforese/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Adsorção , Bacteriófago lambda/química , Bacteriófago lambda/genética , DNA Viral/análise , Eletroforese/métodos , Técnicas Analíticas Microfluídicas/métodos , Polímeros , Dióxido de Silício/química , Estatísticas não Paramétricas
18.
Nano Lett ; 11(6): 2334-41, 2011 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-21526845

RESUMO

Nanoscale ISFET (ion sensitive field-effect transistor) pH sensors are presented that produce the well-known sub-nernstian pH-response for silicon dioxide (SiO(2)) surfaces and near ideal nernstian sensitivity for alumina (Al(2)O(3)) surfaces. Titration experiments of SiO(2) surfaces resulted in a varying pH sensitivity ∼20 mV/pH for pH near 2 and >45 mV/pH for pH > 5. Measured pH responses from titrations of thin (15 nm) atomic layer deposited (ALD) alumina (Al(2)O(3)) surfaces on the nanoISFETs resulted in near ideal nernstian pH sensitivity of 57.8 ± 1.2 mV/pH (pH range: 2-10; T = 22 °C) and temperature sensitivity of 0.19 mV/pH °C (22 °C ≤ T ≤ 40 °C). A comprehensive analytical model of the nanoISFET sensor, which is based on the combined Gouy-Chapman-Stern and Site-Binding (GCS-SB) model, accompanies the experimental results and an extracted ΔpK ≈ 1.5 from the measured responses further supports the near ideal nernstian pH sensitivity.


Assuntos
Óxido de Alumínio/química , Nanoestruturas/química , Dióxido de Silício/química , Transistores Eletrônicos , Eletrodos , Concentração de Íons de Hidrogênio , Propriedades de Superfície
19.
Lab Chip ; 11(12): 1995-2001, 2011 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-21279234

RESUMO

In this article a new parallel electrode structure in a microfluidic channel is described that makes use of a floating electrode to get a homogeneous electrical field. Compared to existing parallel electrode structures, the new structure has an easier production process and there is no need for an electrical connection to both sides of the microfluidic chip. With the new chip design, polystyrene beads suspended in background electrolyte have been detected using electrical impedance measurements. The results of electrical impedance changes caused by beads passing the electrodes are compared with results in a similar planar electrode configuration. It is shown that in the new configuration the coefficient of variation of the impedance changes is lower compared to the planar configuration (0.39 versus 0.56) and less dependent on the position of the beads passage in the channel as a result of the homogeneous electrical field. To our knowledge this is the first time that a floating electrode is used for the realization of a parallel electrode structure. The proposed production method for parallel electrodes in microfluidic channels can easily be applied to other applications.


Assuntos
Eletrodos , Técnicas Analíticas Microfluídicas/instrumentação , Impedância Elétrica , Eletricidade , Técnicas Analíticas Microfluídicas/métodos
20.
Lab Chip ; 10(8): 986-90, 2010 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-20358104

RESUMO

We present an electrokinetic label-free biomolecular screening chip (Glass/PDMS) to screen up to 10 samples simultaneously using surface plasmon resonance imaging (iSPR). This approach reduces the duration of an experiment when compared to conventional experimental methods. This new device offers a high degree of parallelization not only for analyte samples, but also for multiplex analyte interactions where up to 90 ligands are immobilized on the sensing surface. The proof of concept has been demonstrated with well-known biomolecular interactant pairs. The new chip can be used for high throughput screening applications and kinetics parameter extraction, simultaneously, of interactant-protein complex formation.


Assuntos
Eletrônica/instrumentação , Imunoensaio/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Mapeamento de Interação de Proteínas/instrumentação , Ressonância de Plasmônio de Superfície/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Cinética , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Coloração e Rotulagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...