Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Aerosol Med Pulm Drug Deliv ; 36(5): 235-245, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37262184

RESUMO

Background: Significant evidence suggests that SARS-CoV-2 can be transmitted via respiratory aerosols, which are known to vary as a function of respiratory activity. Most animal models examine disease presentation following inhalation of small-particle aerosols similar to those generated during quiet breathing or speaking. However, despite evidence that particle size can influence dose-infectivity relationships and disease presentation for other microorganisms, no studies have examined the infectivity of SARS-CoV-2 contained in larger particle aerosols similar to those produced during coughing, singing, or talking. Therefore, the aim of the present study was to assess the influence of aerodynamic diameter on the infectivity and virulence of aerosols containing SARS-CoV-2 in a hamster model of inhalational COVID-19. Methods: Dose-response relationships were assessed for two different aerosol particle size distributions, with mass median aerodynamic diameters (MMADs) of 1.3 and 5.2 µm in groups of Syrian hamsters exposed to aerosols containing SARS-CoV-2. Results: Disease was characterized by viral shedding in oropharyngeal swabs, increased respiratory rate, decreased activity, and decreased weight gain. Aerosol particle size significantly influenced the median doses to induce seroconversion and viral shedding, with both increasing ∼30-fold when the MMAD was increased. In addition, disease presentation was dose-dependent, with seroconversion and viral shedding occurring at lower doses than symptomatic disease characterized by increased respiratory rate and decreased activity. Conclusions: These results suggest that aerosol particle size may be an important factor influencing the risk of COVID-19 transmission and needs to be considered when developing animal models of disease. This result agrees with numerous previous studies with other microorganisms and animal species, suggesting that it would be generally translatable across different species. However, it should be noted that the absolute magnitude of the observed shifts in the median doses obtained with the specific particle sizes utilized herein may not be directly applicable to other species.


Assuntos
COVID-19 , Animais , Cricetinae , Mesocricetus , Administração por Inalação , Tamanho da Partícula , SARS-CoV-2 , Aerossóis e Gotículas Respiratórios , Gravidade do Paciente
2.
J Aerosol Med Pulm Drug Deliv ; 35(6): 296-306, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36318785

RESUMO

Background: As the COVID-19 pandemic has progressed, numerous variants of SARS-CoV-2 have arisen, with several displaying increased transmissibility. Methods: The present study compared dose-response relationships and disease presentation in nonhuman primates infected with aerosols containing an isolate of the Gamma variant of SARS-CoV-2 to the results of our previous study with the earlier WA-1 isolate of SARS-CoV-2. Results: Disease in Gamma-infected animals was mild, characterized by dose-dependent fever and oronasal shedding of virus. Differences were observed in shedding in the upper respiratory tract between Gamma- and WA-1-infected animals that have the potential to influence disease transmission. Specifically, the estimated median doses for shedding of viral RNA or infectious virus in nasal swabs were approximately 10-fold lower for the Gamma variant than the WA-1 isolate. Given that the median doses for fever were similar, this suggests that there is a greater difference between the median doses for viral shedding and fever for Gamma than for WA-1 and potentially an increased range of doses for Gamma over which asymptomatic shedding and disease transmission are possible. Conclusions: These results complement those of previous studies, which suggested that differences in exposure dose may help to explain the range of clinical disease presentations observed in individuals with COVID-19, highlighting the importance of public health measures designed to limit exposure dose, such as masking and social distancing. The dose-response data provided by this study are important to inform disease transmission and hazard modeling, as well as to inform dose selection in future studies examining the efficacy of therapeutics and vaccines in animal models of inhalational COVID-19.


Assuntos
COVID-19 , SARS-CoV-2 , Animais , Humanos , Pandemias/prevenção & controle , Administração por Inalação , Primatas
3.
J Photochem Photobiol B ; 233: 112503, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35779426

RESUMO

Numerous studies have demonstrated that SARS-CoV-2 can be inactivated by ultraviolet (UV) radiation. However, there are few data available on the relative efficacy of different wavelengths of UV radiation and visible light, which complicates assessments of UV decontamination interventions. The present study evaluated the effects of monochromatic radiation at 16 wavelengths from 222 nm through 488 nm on SARS-CoV-2 in liquid aliquots and dried droplets of water and simulated saliva. The data were used to generate a set of action spectra which quantify the susceptibility of SARS-CoV-2 to genome damage and inactivation across the tested wavelengths. UVC wavelengths (≤280 nm) were most effective for inactivating SARS-CoV-2, although inactivation rates were dependent on sample type. Results from this study suggest that UV radiation can effectively inactivate SARS-CoV-2 in liquids and dried droplets, and provide a foundation for understanding the factors which affect the efficacy of different wavelengths in real-world settings.


Assuntos
COVID-19 , SARS-CoV-2 , Desinfecção/métodos , Humanos , Luz , Raios Ultravioleta , Inativação de Vírus/efeitos da radiação
4.
PLoS Pathog ; 17(8): e1009865, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34424943

RESUMO

While evidence exists supporting the potential for aerosol transmission of SARS-CoV-2, the infectious dose by inhalation remains unknown. In the present study, the probability of infection following inhalation of SARS-CoV-2 was dose-dependent in a nonhuman primate model of inhalational COVID-19. The median infectious dose, assessed by seroconversion, was 52 TCID50 (95% CI: 23-363 TCID50), and was significantly lower than the median dose for fever (256 TCID50, 95% CI: 102-603 TCID50), resulting in a group of animals that developed an immune response post-exposure but did not develop fever or other clinical signs of infection. In a subset of these animals, virus was detected in nasopharyngeal and/or oropharyngeal swabs, suggesting that infected animals without signs of disease are able to shed virus and may be infectious, which is consistent with reports of asymptomatic spread in human cases of COVID-19. These results suggest that differences in exposure dose may be a factor influencing disease presentation in humans, and reinforce the importance of public health measures that limit exposure dose, such as social distancing, masking, and increased ventilation. The dose-response data provided by this study are important to inform disease transmission and hazard modeling, and, ultimately, mitigation strategies. Additionally, these data will be useful to inform dose selection in future studies examining the efficacy of therapeutics and vaccines against inhalational COVID-19, and as a baseline in healthy, young adult animals for assessment of the importance of other factors, such as age, comorbidities, and viral variant, on the infectious dose and disease presentation.


Assuntos
COVID-19/transmissão , COVID-19/virologia , Macaca fascicularis , Soroconversão , Animais , Chlorocebus aethiops , Modelos Animais de Doenças , Feminino , Febre/virologia , Exposição por Inalação , Masculino , Células Vero , Carga Viral
5.
J Infect Dis ; 224(10): 1641-1648, 2021 11 22.
Artigo em Inglês | MEDLINE | ID: mdl-33822064

RESUMO

BACKGROUND: Our laboratory previously examined the influence of environmental conditions on the stability of an early isolate of SARS-CoV-2 (hCoV-19/USA/WA-1/2020) in aerosols generated from culture medium or simulated saliva. However, genetic differences have emerged among SARS-CoV-2 lineages, and it is possible that these differences may affect environmental stability and the potential for aerosol transmission. METHODS: The influence of temperature, relative humidity, and simulated sunlight on the decay of 4 SARS-CoV-2 isolates in aerosols, including 1 belonging to the recently emerged B.1.1.7 lineage, were compared in a rotating drum chamber. Aerosols were generated from simulated respiratory tract lining fluid to represent aerosols originating from the deep lung. RESULTS: No differences in the stability of the isolates were observed in the absence of simulated sunlight at either 20°C or 40°C. However, a small but statistically significant difference in the stability was observed between some isolates in simulated sunlight at 20°C and 20% relative humidity. CONCLUSIONS: The stability of SARS-CoV-2 in aerosols does not vary greatly among currently circulating lineages, including B.1.1.7, suggesting that the increased transmissibility associated with recent SARS-CoV-2 lineages is not due to enhanced survival in the environment.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , Umidade , Aerossóis e Gotículas Respiratórios
6.
J Virol Methods ; 292: 114116, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33689788

RESUMO

A variety of methods have been developed for quantification of infectious Ebola virus in clinical or laboratory samples, but existing methods often require extensive operator involvement, manual assay scoring, or the use of custom reagents. In this study, we utilize a recently developed Ebola-specific reporter cell line that expresses ZsGreen in response to Ebola virus infection, in conjunction with semi-automated processing and quantification techniques, to develop an unbiased, high-throughput microtitration assay for quantification of infectious Ebola virus in vitro. This assay was found to have equivalent sensitivity to a standardized plaque assay for quantifying viral titers. However, the new assay could be implemented with fewer reagents and processing steps, reduced subjectivity, and higher throughput. This assay may be useful for a variety of applications, particularly studies that require the detection or quantification of infectious Ebola virus in large numbers of samples.


Assuntos
Ebolavirus , Doença pelo Vírus Ebola , Linhagem Celular , Doença pelo Vírus Ebola/diagnóstico , Ensaios de Triagem em Larga Escala , Humanos
7.
Environ Chem Lett ; 19(2): 1773-1777, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33551702

RESUMO

In the absence of a vaccine, preventing the spread of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is the primary means to reduce the impact of the 2019 coronavirus disease (COVID-19). Multiple studies have reported the presence of SARS-CoV-2 genetic material on surfaces suggesting that fomite transmission of SARS-CoV-2 is feasible. High temperature inactivation of virus has been previously suggested, but not shown. In the present study, we investigated the environmental stability of SARS-CoV-2 in a clinically relevant matrix dried onto stainless steel at a high temperature. The results show that at 54.5 °C, the virus half-life was 10.8 ± 3.0 min and the time for a 90% decrease in infectivity was 35.4 ± 9.0 min. These findings suggest that in instances where the environment can reach temperatures of at least 54.5 °C, such as in vehicle interior cabins when parked in warmer ambient air, that the potential for exposure to infectious virus on surfaces could be decreased substantially in under an hour.

8.
PLoS Negl Trop Dis ; 15(2): e0009001, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33524051

RESUMO

Previous field and laboratory studies investigating airborne Burkholderia pseudomallei have used a variety of different aerosol samplers to detect and quantify concentrations of the bacteria in aerosols. However, the performance of aerosol samplers can vary in their ability to preserve the viability of collected microorganisms, depending on the resistance of the organisms to impaction, desiccation, or other stresses associated with the sampling process. Consequently, sampler selection is critical to maximizing the probability of detecting viable microorganisms in collected air samples in field studies and for accurate determination of aerosol concentrations in laboratory studies. To inform such decisions, the present study assessed the performance of four laboratory aerosol samplers, specifically the all-glass impinger (AGI), gelatin filter, midget impinger, and Mercer cascade impactor, for collecting aerosols containing B. pseudomallei generated from suspensions in two types of culture media. The results suggest that the relative performance of the sampling devices is dependent on the suspension medium utilized for aerosolization. Performance across the four samplers was similar for aerosols generated from suspensions supplemented with 4% glycerol. However, for aerosols generated from suspensions without glycerol, use of the filter sampler or an impactor resulted in significantly lower estimates of the viable aerosol concentration than those obtained with either the AGI or midget impinger. These results demonstrate that sampler selection has the potential to affect estimation of doses in inhalational animal models of melioidosis, as well as the likelihood of detection of viable B. pseudomallei in the environment, and will be useful to inform design of future laboratory and field studies.


Assuntos
Técnicas Bacteriológicas/instrumentação , Burkholderia pseudomallei/isolamento & purificação , Nebulizadores e Vaporizadores , Aerossóis , Carga Bacteriana , Burkholderia pseudomallei/crescimento & desenvolvimento
9.
Inhal Toxicol ; 33(1): 1-7, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33403871

RESUMO

OBJECTIVE: For many agents, the aerodynamic particle size can affect both the virulence and disease course in animal models. Botulinum neurotoxins (BoNTs), which are widely known as potential bioterrorism agents, have been shown to be toxic via multiple routes of exposure, including small particle inhalation (1-3 µm MMAD). However, the impact of larger particle sizes on the potency of BoNT has not been previously reported. In this study, we compared the potency of BoNT in small and large particle aerosols. MATERIALS AND METHODS: Outbred mice (ICR (CD-1®)) were exposed to BoNT-containing aerosols with differing mass median aerodynamic diameters (MMADs) of 1.1, 4.9, and 7.6 microns. The effects of bioaerosol sampler and inhalation exposure modality were studied. RESULTS AND DISCUSSION: Collecting aerosolized BoNT onto gelatin filters or into liquid impingers resulted in equivalent estimates of aerosol concentration. Nose-only and whole-body inhalation exposure resulted in nearly identical estimates of the median lethal dose (LD50). The LD50 for inhaled BoNT increased approximately 50-fold when the median aerodynamic particle size was increased from 1.1 to 4.9 µm, from 139 (95% CI: 111-185) to 7324 (95% CI: 4287-10 891) mouse intraperitoneal median lethal doses (MIPLD50). These results demonstrate the importance of aerodynamic particle size and regional deposition patterns with regards to BoNT inhalational toxicity. CONCLUSIONS: These data will be useful for medical countermeasure development, as well as biodefense preparedness modeling by demonstrating that the estimates of dose and toxicity of an inhaled aerosol containing BoNT can be significantly affected by a range of factors.


Assuntos
Poluentes Atmosféricos/toxicidade , Toxinas Botulínicas/administração & dosagem , Toxinas Botulínicas/toxicidade , Tamanho da Partícula , Animais , Exposição por Inalação , Dose Letal Mediana , Camundongos
10.
Aerosol Sci Technol ; 55(8): 975-986, 2021 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38076006

RESUMO

To assess the risk of aerosol transmission of SARS-CoV-2, measurements of the airborne viral concentrations in proximity to infected individuals, the persistence of the virus in aerosols, and the dose of the virus needed to cause infection following inhalation are required. For studies aimed at quantifying these parameters, an aerosol sampling device needs to be employed. A number of recent studies have reported the detection of both genetic material and infectious SARS-CoV-2 virus in air samples collected in clinical settings. Previous studies have demonstrated that the efficiency of different samplers for collection and preservation of the infectivity of microorganisms can vary as a function of the specific microorganism. In the present study, the performance of eight common low-flow aerosol sampling devices were compared for their ability to collect and preserve the infectivity of airborne SARS-CoV-2 contained in small particle aerosols. The influence of sampling duration on recovery of infectious virus was also evaluated. Similar concentrations of infectious SARS-CoV-2 were measured in aerosols for the majority of the samplers tested, with the exception of the midget impingers, which measured significantly lower concentrations of SARS-CoV-2. Additionally, in three of the four impingers tested, additional clean airflow through the device following collection of infectious virus resulted in a decrease of the infectious concentration of virus over time, suggesting that virus was being inactivated and these devices may not be suitable for sampling for long durations. Further, RNA copies in the samples over time did not correspond with the losses of infectious SARS-CoV-2 observed in the impingers samples. These data can be utilized to inform interpretation of current studies on the SARS-CoV-2 viral loads in air samples, as well as inform sampling device selection in future studies.

11.
Aerosol Sci Technol ; 55(2): 142-153, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-38077296

RESUMO

Recent evidence suggests that respiratory aerosols may play a role in the spread of SARS-CoV-2 during the ongoing COVID-19 pandemic. Our laboratory has previously demonstrated that simulated sunlight inactivated SARS-CoV-2 in aerosols and on surfaces. In the present study, we extend these findings to include the persistence of SARS-CoV-2 in aerosols across a range of temperature, humidity, and simulated sunlight levels using an environmentally controlled rotating drum aerosol chamber. The results demonstrate that temperature, simulated sunlight, and humidity are all significant factors influencing the persistence of infectious SARS-CoV-2 in aerosols, but that simulated sunlight and temperature have a greater influence on decay than humidity across the range of conditions tested. The time needed for a 90% decrease in infectious virus ranged from 4.8 min at 40 °C, 20% relative humidity, and high intensity simulated sunlight representative of noon on a clear day on the summer solstice at 4°N latitude, to greater than two hours under conditions representative of those expected indoors or at night. These results suggest that the persistence of infectious SARS-CoV-2 in naturally occurring aerosols may be affected by environmental conditions, and that aerosolized virus could remain infectious for extended periods of time under some environmental conditions. The present study provides a comprehensive dataset on the influence of environmental parameters on the survival of SARS-CoV-2 in aerosols that can be utilized, along with data on viral shedding from infected individuals and the inhalational infectious dose, to inform future modeling and risk assessment efforts.

12.
mSphere ; 5(4)2020 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-32611701

RESUMO

Coronavirus disease 2019 (COVID-19) was first identified in China in late 2019 and is caused by newly identified severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Previous studies had reported the stability of SARS-CoV-2 in cell culture media and deposited onto surfaces under a limited set of environmental conditions. Here, we broadly investigated the effects of relative humidity, temperature, and droplet size on the stability of SARS-CoV-2 in a simulated clinically relevant matrix dried on nonporous surfaces. The results show that SARS-CoV-2 decayed more rapidly when either humidity or temperature was increased but that droplet volume (1 to 50 µl) and surface type (stainless steel, plastic, or nitrile glove) did not significantly impact decay rate. At room temperature (24°C), virus half-life ranged from 6.3 to 18.6 h depending on the relative humidity but was reduced to 1.0 to 8.9 h when the temperature was increased to 35°C. These findings suggest that a potential for fomite transmission may persist for hours to days in indoor environments and have implications for assessment of the risk posed by surface contamination in indoor environments.IMPORTANCE Mitigating the transmission of SARS-CoV-2 in clinical settings and public spaces is critically important to reduce the number of COVID-19 cases while effective vaccines and therapeutics are under development. SARS-CoV-2 transmission is thought to primarily occur through direct person-to-person transfer of infectious respiratory droplets or through aerosol-generating medical procedures. However, contact with contaminated surfaces may also play a significant role. In this context, understanding the factors contributing to SARS-CoV-2 persistence on surfaces will enable a more accurate estimation of the risk of contact transmission and inform mitigation strategies. To this end, we have developed a simple mathematical model that can be used to estimate virus decay on nonporous surfaces under a range of conditions and which may be utilized operationally to identify indoor environments in which the virus is most persistent.


Assuntos
Fômites/virologia , Umidade , Modelos Teóricos , Coronavírus Relacionado à Síndrome Respiratória Aguda Grave/fisiologia , Temperatura , Inativação de Vírus , Poluição do Ar em Ambientes Fechados , COVID-19 , Infecções por Coronavirus/prevenção & controle , Infecções por Coronavirus/transmissão , Infecções por Coronavirus/virologia , Meia-Vida , Humanos , Pandemias/prevenção & controle , Plásticos , Pneumonia Viral/prevenção & controle , Pneumonia Viral/transmissão , Pneumonia Viral/virologia , Porosidade , Saliva/química , Saliva/virologia , Aço Inoxidável , Propriedades de Superfície
13.
J Infect Dis ; 222(4): 564-571, 2020 07 23.
Artigo em Inglês | MEDLINE | ID: mdl-32525979

RESUMO

Aerosols represent a potential transmission route of COVID-19. This study examined effect of simulated sunlight, relative humidity, and suspension matrix on stability of SARS-CoV-2 in aerosols. Simulated sunlight and matrix significantly affected decay rate of the virus. Relative humidity alone did not affect the decay rate; however, minor interactions between relative humidity and other factors were observed. Mean decay rates (± SD) in simulated saliva, under simulated sunlight levels representative of late winter/early fall and summer were 0.121 ±â€…0.017 min-1 (90% loss, 19 minutes) and 0.306 ±â€…0.097 min-1 (90% loss, 8 minutes), respectively. Mean decay rate without simulated sunlight across all relative humidity levels was 0.008 ±â€…0.011 min-1 (90% loss, 286 minutes). These results suggest that the potential for aerosol transmission of SARS-CoV-2 may be dependent on environmental conditions, particularly sunlight. These data may be useful to inform mitigation strategies to minimize the potential for aerosol transmission.


Assuntos
Microbiologia do Ar , Betacoronavirus/efeitos da radiação , Infecções por Coronavirus/transmissão , Pneumonia Viral/transmissão , Luz Solar , Aerossóis , Animais , COVID-19 , Chlorocebus aethiops , Simulação por Computador , Meios de Cultura , Umidade , Concentração de Íons de Hidrogênio , Pandemias , Análise de Regressão , SARS-CoV-2 , Saliva/química , Saliva/virologia , Células Vero
14.
J Infect Dis ; 222(2): 214-222, 2020 06 29.
Artigo em Inglês | MEDLINE | ID: mdl-32432672

RESUMO

Previous studies have demonstrated that SARS-CoV-2 is stable on surfaces for extended periods under indoor conditions. In the present study, simulated sunlight rapidly inactivated SARS-CoV-2 suspended in either simulated saliva or culture media and dried on stainless steel coupons. Ninety percent of infectious virus was inactivated every 6.8 minutes in simulated saliva and every 14.3 minutes in culture media when exposed to simulated sunlight representative of the summer solstice at 40°N latitude at sea level on a clear day. Significant inactivation also occurred, albeit at a slower rate, under lower simulated sunlight levels. The present study provides the first evidence that sunlight may rapidly inactivate SARS-CoV-2 on surfaces, suggesting that persistence, and subsequently exposure risk, may vary significantly between indoor and outdoor environments. Additionally, these data indicate that natural sunlight may be effective as a disinfectant for contaminated nonporous materials.


Assuntos
Betacoronavirus , Infecções por Coronavirus , Pandemias , Pneumonia Viral , Coronavírus Relacionado à Síndrome Respiratória Aguda Grave , COVID-19 , Humanos , SARS-CoV-2 , Luz Solar
15.
J Infect Dis ; 221(3): 372-378, 2020 01 14.
Artigo em Inglês | MEDLINE | ID: mdl-31778532

RESUMO

BACKGROUND: Environmental parameters, including sunlight levels, are known to affect the survival of many microorganisms in aerosols. However, the impact of sunlight on the survival of influenza virus in aerosols has not been previously quantified. METHODS: The present study examined the influence of simulated sunlight on the survival of influenza virus in aerosols at both 20% and 70% relative humidity using an environmentally controlled rotating drum aerosol chamber. RESULTS: Measured decay rates were dependent on the level of simulated sunlight, but they were not significantly different between the 2 relative humidity levels tested. In darkness, the average decay constant was 0.02 ± 0.06 min-1, equivalent to a half-life of 31.6 minutes. However, at full intensity simulated sunlight, the mean decay constant was 0.29 ± 0.09 min-1, equivalent to a half-life of approximately 2.4 minutes. CONCLUSIONS: These results are consistent with epidemiological findings that sunlight levels are inversely correlated with influenza transmission, and they can be used to better understand the potential for the virus to spread under varied environmental conditions.


Assuntos
Vírus da Influenza A Subtipo H1N1/efeitos da radiação , Infecções por Orthomyxoviridae/transmissão , Infecções por Orthomyxoviridae/virologia , Luz Solar , Raios Ultravioleta , Aerossóis , Animais , Cães , Umidade , Células Madin Darby de Rim Canino , Temperatura
16.
J Am Assoc Lab Anim Sci ; 56(6): 792-801, 2017 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-29256375

RESUMO

We used a continuous-monitoring digital telemetry system to investigate temperature response in New Zealand White rabbits after inhalation or subcutaneous challenge with Bacillus anthracis. Two spore preparations of B. anthracis Ames A2084 were evaluated by using a nose-only inhalation model, and 2 strains, B. anthracis Ames A2084 and B. anthracis UT500, were evaluated in a subcutaneous model. Animal body temperature greater than 3 SD above the mean baseline temperature was considered a significant increase in body temperature (SIBT). All rabbits that exhibited SIBT after challenge by either route of infection or bacterial strain eventually died or were euthanized due to infection, and all rabbits that died or were euthanized due to infection exhibited SIBT during the course of disease. The time at onset of SIBT preceded clinical signs of disease in 94% of the rabbits tested by as long as 2 days. In addition, continuous temperature monitoring facilitated discrimination between the 2 B. anthracis strains with regard to the time interval between SIBT and death. These data suggest that for the New Zealand White rabbit anthrax model, SIBT is a reliable indicator of infection, is predictive of experimental outcome in the absence of treatment, and is measurable prior to the appearance of more severe signs of disease. The use of digital telemetry to monitor infectious disease course in animal models of anthrax can potentially be used in conjunction with other clinical score metrics to refine endpoint euthanasia criteria.


Assuntos
Antraz/veterinária , Coelhos , Telemetria/veterinária , Aerossóis , Animais , Animais de Laboratório , Antraz/microbiologia , Antraz/fisiopatologia , Bacillus anthracis/química , Bacillus anthracis/classificação , Bacillus anthracis/patogenicidade , Temperatura Corporal , Modelos Animais de Doenças , Febre/veterinária , Inalação
17.
Appl Environ Microbiol ; 82(9): 2809-2818, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26944839

RESUMO

UNLABELLED: Public health and decontamination decisions following an event that causes indoor contamination with a biological agent require knowledge of the environmental persistence of the agent. The goals of this study were to develop methods for experimentally depositing bacteria onto indoor surfaces via aerosol, evaluate methods for sampling and enumerating the agent on surfaces, and use these methods to determine bacterial surface decay. A specialized aerosol deposition chamber was constructed, and methods were established for reproducible and uniform aerosol deposition of bacteria onto four coupon types. The deposition chamber facilitated the control of relative humidity (RH; 10 to 70%) following particle deposition to mimic the conditions of indoor environments, as RH is not controlled by standard heating, ventilation, and air conditioning (HVAC) systems. Extraction and culture-based enumeration methods to quantify the viable bacteria on coupons were shown to be highly sensitive and reproducible. To demonstrate the usefulness of the system for decay studies,Yersinia pestis persistence as a function of surface type at 21 °C and 40% RH was determined to be >40%/min for all surfaces. Based upon these results, at typical indoor temperature and RH, a 6-log reduction in titer would expected to be achieved within 1 h as the result of environmental decay on surfaces without active decontamination. The developed approach will facilitate future persistence and decontamination studies with a broad range of biological agents and surfaces, providing agent decay data to inform both assessments of risk to personnel entering a contaminated site and decontamination decisions following biological contamination of an indoor environment. IMPORTANCE: Public health and decontamination decisions following contamination of an indoor environment with a biological agent require knowledge of the environmental persistence of the agent. Previous studies on Y. pestis persistence have utilized large liquid droplet deposition to provide persistence data. As a result, methods were developed to deposit aerosols containing bacteria onto indoor surfaces, reproducibly enumerate bacteria harvested from coupons, and determine surface decay utilizing Y. pestis The results of this study provide foundational methods required to evaluate surface decay of bacteria and potentially other biological agents, such as viruses, in aerosol particles as a function of surface type and environment. Integrating the data from both aerosol and liquid deposition surface decay studies will provide medical and public health personnel with a more complete understanding of agent persistence on surfaces in contaminated areas for assessment of health risks and to inform decontamination decisions.


Assuntos
Monitoramento Ambiental/métodos , Yersinia pestis/isolamento & purificação , Aerossóis , Poluição do Ar em Ambientes Fechados/análise , Descontaminação/métodos , Microbiologia Ambiental , Monitoramento Ambiental/instrumentação , Contaminação de Equipamentos , Desenho de Equipamento , Calefação , Umidade , Viabilidade Microbiana , Tamanho da Partícula , Sonicação/métodos , Esporos Bacterianos/isolamento & purificação , Propriedades de Superfície , Temperatura
18.
Chem Biol Interact ; 238: 161-9, 2015 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-26145887

RESUMO

Serum-derived human butyrylcholinesterase (Hu BChE) is a stoichiometric bioscavenger that is being developed as a potential prophylactic nerve agent countermeasure. Previously, we reported the prophylactic efficacy of Hu BChE in Göttingen minipigs against a whole-body exposure to 4.1mg/m(3) of sarin (GB) vapor, which produced lethality over 60min. Since the toxicity of nerve agent is concentration-dependent, in the present study, we investigated the toxic effects of an almost 3-fold higher rate of GB vapor exposure and the ability of Hu BChE to protect minipigs against this exposure. Male minipigs were subjected to: (1) air exposure; (2) GB vapor exposure; or (3) pretreatment with 7.5mg/kg of Hu BChE by i.m. injection, 24h prior to whole-body exposure to 11.4mg/m(3) of GB vapor for 10min. Electrocardiogram, electroencephalogram, and pupil size were monitored throughout exposure. Blood drawn before and throughout exposure was analyzed for blood gases, electrolytes, metabolites, acetylcholinesterase and BChE activities, and amount of GB bound to red blood cells and plasma. A novel finding was that saline-treated animals exposed to GB vapor did not develop any seizures, but manifested a variety of cardiac and whole blood toxic signs and rapidly died due to respiratory failure. Strikingly, pre-treatment with 7.5mg/kg of Hu BChE not only prevented lethality, but also avoided all cardiac toxic signs manifested in the non-treated cohort. Thus, Hu BChE alone can serve as an effective prophylactic countermeasure versus a lethal high-dose exposure to GB vapor.


Assuntos
Butirilcolinesterase/farmacologia , Substâncias para a Guerra Química/toxicidade , Sarina/toxicidade , Convulsões/induzido quimicamente , Acetilcolinesterase/metabolismo , Animais , Análise Química do Sangue , Butirilcolinesterase/metabolismo , Eletrocardiografia , Eletroencefalografia , Gases/química , Humanos , Masculino , Miose/induzido quimicamente , Miose/patologia , Insuficiência Respiratória/induzido quimicamente , Insuficiência Respiratória/patologia , Convulsões/patologia , Suínos , Porco Miniatura
19.
Viruses ; 4(10): 2115-36, 2012 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-23202456

RESUMO

Filoviruses are members of the genera Ebolavirus, Marburgvirus, and "Cuevavirus". Because they cause human disease with high lethality and could potentially be used as a bioweapon, these viruses are classified as CDC Category A Bioterrorism Agents. Filoviruses are relatively stable in aerosols, retain virulence after lyophilization, and can be present on contaminated surfaces for extended periods of time. This study explores the characteristics of aerosolized Sudan virus (SUDV) Boniface in non-human primates (NHP) belonging to three different species. Groups of cynomolgus macaques (cyno), rhesus macaques (rhesus), and African green monkeys (AGM) were challenged with target doses of 50 or 500 plaque-forming units (pfu) of aerosolized SUDV. Exposure to either viral dose resulted in increased body temperatures in all three NHP species beginning on days 4-5 post-exposure. Other clinical findings for all three NHP species included leukocytosis, thrombocytopenia, anorexia, dehydration, and lymphadenopathy. Disease in all of the NHPs was severe beginning on day 6 post-exposure, and all animals except one surviving rhesus macaque were euthanized by day 14. Serum alanine transaminase (ALT) and aspartate transaminase (AST) concentrations were elevated during the course of disease in all three species; however, AGMs had significantly higher ALT and AST concentrations than cynos and rhesus. While all three species had detectable viral load by days 3-4 post exposure, Rhesus had lower average peak viral load than cynos or AGMs. Overall, the results indicate that the disease course after exposure to aerosolized SUDV is similar for all three species of NHP.


Assuntos
Chlorocebus aethiops/virologia , Infecções por Filoviridae/patologia , Filoviridae/patogenicidade , Macaca fascicularis/virologia , Macaca mulatta/virologia , Aerossóis , Alanina Transaminase/sangue , Animais , Aspartato Aminotransferases/sangue , Pressão Sanguínea , Temperatura Corporal , Modelos Animais de Doenças , Feminino , Infecções por Filoviridae/virologia , Frequência Cardíaca , Exposição por Inalação , Estimativa de Kaplan-Meier , Contagem de Leucócitos , Leucocitose/patologia , Leucocitose/virologia , Masculino , Índice de Gravidade de Doença , Telemetria , Fatores de Tempo , Células Vero , Carga Viral
20.
Artigo em Inglês | MEDLINE | ID: mdl-22919669

RESUMO

Burkholderia thailandensis is used in the laboratory as a surrogate of the more virulent B. pseudomallei. Since inhalation is believed to be a natural route of infection for B. pseudomallei, many animal studies with B. pseudomallei and B. thailandensis utilize the inhalation route of exposure. The aim of the present study was to quantify the recovery efficiency of culturable B. thailandensis from several common aerosol sampling devices to ensure that collected microorganisms could be reliably recovered post-collection. The sampling devices tested included 25 mm gelatin filters, 22 mm stainless steel disks used in Mercer cascade impactors, and two types of glass impingers. The results demonstrate that while several processing methods tested resulted in significantly lower physical recovery efficiencies than other methods, it was possible to obtain culturable recovery efficiencies for B. thailandensis and physical recovery efficiencies for 1 µm fluorescent spheres of at least 0.95 from all of the sampling media tested given an appropriate sample processing procedure. The results of the present study also demonstrated that the bubbling action of liquid media in all-glass impingers (AGIs) can result in physical loss of material from the collection medium, although additional studies are needed to verify the exact mechanisms involved. Overall, the results of this study demonstrate that the collection mechanism as well as the post-collection processing method can significantly affect the recovery from and retention of culturable microorganisms in sampling media, potentially affecting the calculated airborne concentration and any subsequent estimations of risk or dose derived from such data.


Assuntos
Aerossóis , Microbiologia do Ar , Técnicas Bacteriológicas/métodos , Burkholderia/isolamento & purificação , Manejo de Espécimes/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...