1.
J Chromatogr A ; 958(1-2): 79-88, 2002 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-12134833

RESUMO

Specific programming of automated HPLC systems allows total on-line qualification, validation and stability monitoring using the concept of deferred standards. Setting up such a process for routine analyses in an automated HPLC system requires specific autosampler programming as well as specific monitoring software. With an autosampler, a double injection procedure is programmed, the first introducing the sample, and the second, a few minutes deferred, the deferred control standard. Two additional compounds are therefore added to the sample before and during the chromatographic process: the intemal standard for sample quantification and the deferred standard for system control. Specific methodologies are described of how to obtain classical quantitative analysis information as well as system qualification validation stability information. Experiments were performed to develop specified methodologies to monitor the quality of quantitative analysis during the life of the column by using the deferred standard concept to probe the effects of column ageing on separation characteristics.


Assuntos
Cromatografia Líquida de Alta Pressão/normas , Automação , Cromatografia Líquida de Alta Pressão/métodos , Compostos Policíclicos/análise , Padrões de Referência , Reprodutibilidade dos Testes
2.
J Chromatogr B Biomed Sci Appl ; 759(1): 109-16, 2001 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-11499614

RESUMO

This paper describes a rapid, specific and sensitive method for the determination of 29 organophosphorus pesticides in blood and serum, involving a rapid solid-phase extraction procedure using Oasis HLB cartridges and gas chromatography coupled to mass-selective detection. The ionization was performed by electron Impact and acquisition in the single ion monitoring mode followed three specific ions per analyte. Extraction recoveries were satisfactory and ranged between 40 and 108% in blood and serum. Limits of detection ranged from 5 to 25 ng/ml and limits of quantitation (LOQs) ranged from 10 to 50 ng/ml, in blood and serum. An excellent linearity was observed from these LOQs up to 1000 ng/ml. Intra- and inter-assay precision and accuracy were satisfactory for most of the pesticides analyzed.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas/métodos , Inseticidas/sangue , Compostos Organofosforados , Resíduos de Praguicidas/sangue , Concentração de Íons de Hidrogênio , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
Forensic Sci Int ; 121(1-2): 116-25, 2001 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-11516896

RESUMO

Original and sensitive multiresidue methods are presented for the detection and quantitation, in human biological matrices, of 61 pesticides of toxicological significance in human. These methods involved rapid solid-phase extraction using new polymeric support (HLB and MCX) OASIS cartridges. Gas chromatography-mass spectrometry (GC-MS) was used for volatile (organophosphate, organochlorine, phtalimide, uracil) pesticides and liquid chromatography-ionspray-mass spectrometry (LC-MS) for thermolabile and polar pesticides (carbamates, benzimidazoles). Acquisition was performed in the selected ion monitoring (SIM) mode. Extraction recovery varied owing to the nature of pesticides, but was satisfactory for all. Limits of detection (LODs) and limits of quantitation (LOQs) ranged, respectively, from 2.5 to 20 and from 5 to 50ng/ml. An excellent linearity was observed from LOQs up to 1000ng/ml for all the pesticides studied. The proposed procedures yielded reproducible results with good inter-assay accuracy and precision. A few cases of intoxication are presented to demonstrate the diagnostic interest of these methods: in two cases were determined lethal concentrations of endosulfan and carbofuran; in four other cases, the procedures helped diagnose intoxication with, respectively, parathion-ethyl, the association of bromacil and strychnine, bifenthrin and aldicarb.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas/métodos , Resíduos de Praguicidas/sangue , Adulto , Idoso , Evolução Fatal , Feminino , Medicina Legal , Humanos , Masculino , Sensibilidade e Especificidade , Tentativa de Suicídio , Toxicologia
4.
J Chromatogr Sci ; 37(7): 229-36, 1999 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-10422264

RESUMO

Field-flow fractionation (FFF) is an analytical technique particularly suitable for the separation, isolation, and characterization of macromolecules and micrometer- or submicrometer-sized particles. This chromatographic-like methodology can modulate the retention of micron-sized species according to an elution mode described to date as "steric hyperlayer". In such a model, differences in sample species size, density, or other physical parameters make particle selective elution possible depending on the configuration and the operating conditions of the FFF system. Elution characteristics of micron-sized particles of biological origin, such as cells, can be modified using media and carrier phases of different osmolarities. In these media, a cells average size, density, and shape are modified. Therefore, systematic studies of a single reference cell population, red blood cells (RBCs), are performed with 2 sedimentation FFF systems using either gravity (GrFFF) or a centrifugational field (SdFFF). However, in all cases, normal erythrocyte in isotonic suspension elutes as a single peak when fractionated in these systems. With carrier phases of different osmolarities, FFF elution characteristics of RBCs are modified. Retention modifications are qualitatively consistent with the "steric-hyperlayer" model. Such systematic studies confirm the key role of size, density, and shape in the elution mode of RBCs in sedimentation FFF for living, micronsized biological species. Using polymers as an analogy, the RBC population is described as highly "polydisperse". However, this definition must be reconsidered depending on the parameters under concern, leading to a matricial concept: multipolydispersity. It is observed that multipolydispersity modifications of a given RBC population are qualitatively correlated to the eluted sample band width.


Assuntos
Eritrócitos , Separação Celular , Fracionamento Químico/métodos , Humanos , Concentração Osmolar
5.
J Chromatogr A ; 830(1): 135-43, 1999 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-10023622

RESUMO

This paper describes a rapid, specific and sensitive multi-residue method for the routine quantitative analysis of pesticides of several classes used for the treatment of apples and pears, down to their respective maximum residue limits (MRLs). It involves a rapid extraction procedure and liquid chromatography coupled to electrospray mass selective detection. Seven pesticides were extracted at pH 4.5 with a mixture of acetone-dichloromethane-hexane (50:20:30, v/v/v). Ionization was performed at atmospheric pressure in an electrospray-type source and detection was carried out using the selected ion monitoring (SIM) mode. Extraction recoveries were between 55 and 98% except for methylthiophanate (< 20%). Limits of detection (LODs) and limits of quantitation (LOQs) ranged, respectively, from 0.01 to 0.02 mg/kg and from 0.02 to 0.05 mg/kg, with relative standard deviation (R.S.D.) less than 19%. An excellent linearity was observed for LOQs up to 5 mg/kg. Intermediate ("inter-assay") precision and accuracy were satisfactory. The method was applied to many fruit samples intended for commercialization.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Frutas/química , Espectrometria de Massas/métodos , Resíduos de Praguicidas/análise , Cromatografia em Camada Fina , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
J Pharm Biomed Anal ; 20(3): 503-12, 1999 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-10701966

RESUMO

Toxoplasmosis is a worldwide disease caused by Toxoplasma gondii, an intracellular protozoa of micronic size range (4-10 microm). Its classical purification processes are complex and often associated with low recovery. All investigation procedures concerning this parasite require its isolation and purification from at least the mouse ascitic fluid. For this purpose, a recently developed laboratory technology was used, i.e. sedimentation field-flow fractionation. This chromatographic-like separation technology was demonstrated to be particularly selective for isolation and separation of micron-sized biological particles. Sedimentation field-flow fractionation operated on the steric-hyperlayer mode was used to isolate the parasite from the remanent ascitic contaminants of different origins and from red blood cells. With this technology, 86% recovery with 97% viability was obtained in less than 30 min.


Assuntos
Fracionamento Químico/métodos , Toxoplasma/isolamento & purificação , Animais , Líquido Ascítico/citologia , Líquido Ascítico/parasitologia , Contagem de Células , Separação Celular/instrumentação , Separação Celular/métodos , Fracionamento Químico/instrumentação , Cromatografia/instrumentação , Cromatografia/métodos , Eritrócitos/citologia , Eritrócitos/parasitologia , Estudos de Avaliação como Assunto , Feminino , Gravitação , Humanos , Camundongos , Parasitologia/instrumentação , Parasitologia/métodos , Tamanho da Partícula , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Toxoplasma/crescimento & desenvolvimento , Toxoplasmose/parasitologia
7.
J Chromatogr B Biomed Sci Appl ; 709(2): 197-207, 1998 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-9657216

RESUMO

Sedimentation field-flow fractionation (SdFFF) offers great potential for the separation of submicrometer and micrometer-sized species. The availability of commercial instrumentation and the versatility of this method originated its success. At this stage of development, SdFFF techniques are mature enough for use in analytical research, development and even routine work. However, prior to their use, these techniques like any other methodologies, have to be validated. As the application of SdFFF techniques to cell separation is being constantly developed, we have investigated separation performance according to validation rules classically defined for separation methods (chromatography) in the case of cellular materials.


Assuntos
Separação Celular/métodos , Coleta de Amostras Sanguíneas , Centrifugação , Eritrócitos/citologia , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Manejo de Espécimes
8.
J Chromatogr A ; 805(1-2): 319-26, 1998 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-9618924

RESUMO

This paper describes a rapid, specific and sensitive multiresidue method for the routine analysis of several classes of pesticides used for the treatment of apples and pears, involving a rapid extraction procedure at pH 4.5 with a mixture of acetone-dichloromethane-hexane (50:20:30, v/v/v) and gas chromatography coupled to mass-selective detection, in order to achieve quantitative analysis down to their respective maximum residue limit. Extraction recoveries were between 55 and 98%. Limits of detection and limits of quantitation ranged respectively, from 0.01 to 0.05 mg/kg and from 0.02 to 0.1 mg/kg. Intra-assay relative standard deviation was less than 19% for all compounds. An excellent linearity was observed from these LOQs up to 500 mg/kg. Intermediate (inter-assay) precision and accuracy were satisfactory. The method has been applied to many fruit samples intended for commercialisation.


Assuntos
Frutas/química , Resíduos de Praguicidas/análise , Rosales/química , Cromatografia Gasosa-Espectrometria de Massas , Concentração de Íons de Hidrogênio , Indicadores e Reagentes
9.
Ther Drug Monit ; 19(2): 160-4, 1997 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-9108643

RESUMO

High-performance liquid chromatography has been applied to the simultaneous determination of lidocaine and bupivacaine levels in human plasma, using etidocaine as internal standard. The method was found to be linear in the range 10-2,000 micrograms/l for lidocaine and 20-1,000 micrograms/l for bupivacaine. Within-day and day-to-day coefficients of variation were generally lower than 12%. The method was applied to a pharmacokinetic study of lidocaine and bupivacaine during peribulbar anesthesia in ocular surgery. Both compounds displayed a slow apparent elimination rate. The method described here permitted the determination of the complete pharmacokinetic profiles of the two anesthetics, although they were administered at quite different doses.


Assuntos
Bupivacaína/sangue , Bupivacaína/farmacocinética , Lidocaína/sangue , Lidocaína/farmacocinética , Idoso , Cromatografia Líquida de Alta Pressão , Feminino , Humanos , Masculino
10.
J Anal Toxicol ; 20(2): 93-100, 1996.
Artigo em Inglês | MEDLINE | ID: mdl-8868399

RESUMO

A technique for the simultaneous identification and quantitation of 13 hydroxycoumarin and indandione anticoagulant drugs and rodenticides from human serum by reversed-phase liquid chromatography with diode-array detection has been developed. High-performance liquid chromatography was performed using gradient elution with an acetonitrile and phosphate buffer on a Nucleosil ODS column. Ultraviolet spectra from 200 to 400 nm were recorded on-line during the analysis and compared with spectra stored in a library. For the spiked 2 mL of serum, acidic and alkaline liquid-liquid double extraction with diethylether-ether acetate (50:50, v/v) was conducted, and recoveries greater than 60% for most compounds were found. The detection limit was approximately 25 or 50 ng/mL for all components except for difethialone and fluindione, for which it was approximately 100 ng/mL. The standard calibration curves were linear from the detection limit to 5000 ng/mL. The within-run precision coefficient of variation (CV) was less than 10%, and the between-run precision CV was less than 20%.


Assuntos
Anticoagulantes/sangue , Rodenticidas/sangue , Administração Oral , Técnicas de Química Analítica , Cromatografia Líquida de Alta Pressão , Cumarínicos/sangue , Humanos , Concentração de Íons de Hidrogênio , Indanos/sangue , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrofotometria Ultravioleta
11.
J Anal Toxicol ; 20(2): 134-8, 1996.
Artigo em Inglês | MEDLINE | ID: mdl-8868407

RESUMO

A 47-year-old laboratory assistant ingested approximately 9 g of sodium azide powder and died 4 h later at a hospital. A high-performance liquid chromatographic method using diode-array detection has been developed for the determination of an azide benzoyl derivative in blood (after a simple deproteinization) and in several tissues (after homogenization in a neutral buffer and deproteinization of the supernatant). The blood concentration in this case was lower than those previously published. The highest azide concentration was found in lung tissue. A complete toxicological screening revealed the presence of cyanide in blood, which has been previously reported twice, but for the first time, it was confirmed by mass spectrometry. Whether the production of cyanide in the presence of azide took place in vivo or postmortem remains unknown; the nature of the metabolic pathway involved also remains unknown.


Assuntos
Azidas/intoxicação , Azidas/sangue , Cromatografia Líquida de Alta Pressão , Evolução Fatal , Humanos , Indicadores e Reagentes , Masculino , Pessoa de Meia-Idade , Azida Sódica , Espectrofotometria Ultravioleta , Suicídio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...