1.
Cardiol Res Pract ; 2016: 5265682, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27213077

RESUMO

Radiofrequency catheter ablation (RFA) has become a mainstay for treatment of cardiac arrhythmias. Skin burns at the site of an indifferent electrode patch have been a rare, serious, and likely an underreported complication of RFA. The purpose of this study was to determine the incidence of skin burns in cardiac RFA procedures performed at one institution. Also, we wanted to determine the factors predicting skin burns after cardiac RFA procedures at the indifferent electrode skin pad site. Methods. A retrospective case control study was performed to compare the characteristics in patients who developed skin burns in a 2-year period. Results. Incidence of significant skin burns after RFA was 0.28% (6/2167). Four of the six patients were female and all were Caucasians. Four controls for every case were age and sex matched. Burn patients had significantly higher BMI, procedure time, and postprocedure pain, relative to control subjects (p < 0.05, one-tailed testing). No one in either group had evidence of dispersive pad malattachment. Conclusions. Our results indicate that burn patients had higher BMI and longer procedure times compared to control subjects. These findings warrant further larger studies on this topic.

2.
Cardiovasc Diagn Ther ; 6(1): 3-9, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26885486

RESUMO

BACKGROUND: The optimal strategy of peri-procedural anticoagulation in patients undergoing permanent cardiac device implantation is controversial. Our objective was to compare the major bleeding and thromboembolic complications in patients managed with uninterrupted warfarin (UW) vs. interrupted dabigatran (ID) during permanent pacemaker (PPM) or implantable cardioverter defibrillators (ICD) implantation. METHODS: A retrospective cohort study of all eligible patients from July 2011 through January 2012 was performed. UW was defined as patients who had maintained a therapeutic international normalized ratio (INR) on the day of the procedure. ID was defined as stopping dabigatran ≥12 hours prior to the procedure and then resuming after implantation. Major bleeding events included hemothorax, hemopericardium, intracranial hemorrhage, gastrointestinal bleed, epistaxis, or pocket hematoma requiring surgical intervention. Thromboembolic complications included stroke, transient ischemic attack, deep venous thrombosis, pulmonary embolism, or arterial embolism. RESULTS: Of the 133 patients (73.4±11.0 years; 91 males) in the study, 86 received UW and 47 received ID. One (1.2%) patient in the UW group sustained hemopericardium perioperatively and died. In comparison, the ID patients had no complications. As compared to the ID group, the UW group had a higher median CHADS2 score (2 vs. 3, P=0.04) and incidence of Grade 1 pocket hematoma (0% vs. 7%, P=0.09). Neither group developed any thromboembolic complications. CONCLUSIONS: Major bleeding rates were similar among UW and ID groups. Perioperative ID appears to be a safe anticoagulation strategy for patients undergoing PPM or ICD implantation.

3.
Pacing Clin Electrophysiol ; 37(1): 4-10, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24215291

RESUMO

OBJECTIVE: The purpose of our study was to determine if the rate of lead-related complications was increased with the Medtronic CapSureFix MRI™ SureScan™ 5086 MRI pacing lead (5086; Medtronic Inc., Minneapolis, MN, USA) compared to the previous generation of Medtronic CapSureFix Novus™ 5076 pacing lead (5076). BACKGROUND: The 5086 lead is a newly introduced active-fixation pacemaker lead designed to be used conditionally in a magnetic resonance (MR) scanner. This lead has specific design changes compared to the previous generation of 5076 pacing leads. METHODS: This study was a retrospective case control study of 65 consecutive patients implanted with two 5086 leads compared to 92 consecutive control patients implanted with two 5076 leads over a 14-month period at a high-volume tertiary care hospital. RESULTS: Pericarditis, pericardial effusion, cardiac tamponade, or death within 30 days of implant were seen in eight patients from the 5086 cohort and two from the 5076 cohort (odds ratio 6.3, 95% confidence interval 1.3-30.8, P = 0.02). Lead dislodgement occurred in four of the 5086 patients and in none of the 5076 patients (P < 0.03). CONCLUSIONS: In a high-volume center, the incidence of pericarditis, cardiac perforation, tamponade, death, and lead dislodgement was significantly higher with the MR-conditional Medtronic 5086 lead when compared to the previous generation Medtronic 5076 lead.


Assuntos
Eletrodos Implantados/efeitos adversos , Migração de Corpo Estranho/etiologia , Traumatismos Cardíacos/etiologia , Imageamento por Ressonância Magnética/instrumentação , Marca-Passo Artificial/efeitos adversos , Ferimentos Penetrantes/etiologia , Idoso , Falha de Equipamento , Segurança de Equipamentos , Feminino , Migração de Corpo Estranho/prevenção & controle , Traumatismos Cardíacos/prevenção & controle , Humanos , Imageamento por Ressonância Magnética/efeitos adversos , Masculino , Pericardite/etiologia , Pericardite/prevenção & controle , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas à Prótese/prevenção & controle , Estudos Retrospectivos , Taxa de Sobrevida , Resultado do Tratamento , Ferimentos Penetrantes/prevenção & controle
4.
Glob Cardiol Sci Pract ; 2013(3): 261-8, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24689027

RESUMO

Ventricular arrhythmias in young people most commonly occur due to the presence of hypertrophic cardiomyopathy, long QT syndrome or Wolff-Parkinson-White syndrome. We present a case in which the patient had exercise induced syncopal spells and was found to have ventricular tachycardia (VT) during both exercise stress testing and an electrophysiology study. Further genetic studies showed a previously unseen desmosomal gene mutation confirming the presence of Arrhythmogenic Right Ventricular Cardiomyopathy (ARVC).

5.
Cardiol Clin ; 22(1): 127-45, ix, 2004 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-14994853

RESUMO

The past several years have witnessed a significant growth in the number of institutions offering catheter ablation for atrial fibrillation (AF). This growth has been a result of a better understanding of pathophysiology of AF and use of instruments and approaches that made catheter ablation of AF a safe and an effective alternative to the drug therapy. The procedure increasingly is becoming a therapy of choice for a select group of symptomatic, drug-refractory patients without structural heart disease, and it is being offered to a rapidly widening patient pool. This article reviews the procedural aspects and clinical evidence supporting this wider use of AF ablation. In addition, new techniques and technologies for AF ablation and new avenues of research in this area are explored.


Assuntos
Fibrilação Atrial/terapia , Ablação por Cateter , Ensaios Clínicos como Assunto , Humanos
6.
Am J Cardiol ; 90(11): 1183-6, 2002 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-12450595

RESUMO

Cardiac tamponade is an uncommon but life-threatening complication of percutaneous coronary intervention (PCI). The purpose of the present study was to characterize the incidence, management, and clinical outcome associated with this complication. We analyzed a prospective database of 25,697 PCIs performed at William Beaumont Hospital (Royal Oak, Michigan) between October 1993 and December 2000. Cardiac tamponade was observed in 31 of 25,697 PCI procedures (0.12%). Cardiac tamponade was diagnosed in the catheterization laboratory in 17 of 31 patients (55%), and 14 patients (45%) had a delayed presentation (mean time from PCI 4.4 hours). Cardiac tamponade was twice as frequent after use of atheroablative devices compared with percutaneous transluminal coronary angioplasty and stenting (0.26% vs 0.11%, p <0.05). All patients with immediate cardiac tamponade had coronary artery perforation. In 11 of 14 patients with delayed tamponade (79%), no actual site of perforation could be identified. A moderate or large pericardial effusion was observed in 20 patients, and 9 had small effusions without typical echocardiographic features of tamponade. Pericardiocentesis was performed in 30 patients; 19 patients (61%) were treated successfully with aspiration alone, but 12 patients (39%) required further emergency surgical intervention. In-hospital complications included death (42%), emergency surgery (39%), myocardial infarction (29%), and transfusion (65%). Cardiac tamponade is an uncommon but important complication of PCI and is associated with high mortality and morbidity. Most cases are recognized in the catheterization laboratory, but delayed cardiac tamponade may occur and must be considered as a cause of late hypotension after PCI.


Assuntos
Angioplastia Coronária com Balão/efeitos adversos , Aterectomia Coronária/efeitos adversos , Tamponamento Cardíaco/etiologia , Doença da Artéria Coronariana/terapia , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco , Tamponamento Cardíaco/diagnóstico , Tamponamento Cardíaco/epidemiologia , Tamponamento Cardíaco/terapia , Doença da Artéria Coronariana/diagnóstico , Ecocardiografia , Hidratação , Mortalidade Hospitalar , Humanos , Incidência , Pessoa de Meia-Idade , Pericardiocentese , Estudos Retrospectivos
7.
Clin Cardiol ; 25(8): 363-6, 2002 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12173902

RESUMO

BACKGROUND: The majority of cardiovascular deaths occur in the elderly. The safety and results of primary infarct intervention in octogenarians is not well characterized. HYPOTHESIS: The purpose of this study was to compare the results of primary infarct intervention in octogenarians with those in younger patients during 1997-1998 and to compare these results to those obtained in octogenarians treated in 1991-1994. METHODS: During 1997-1998, 40 octogenarians were treated with primary infarct intervention and were compared with 60 randomly selected patients aged < 80 years treated during the same time period. The results in octogenarians were compared with the results in a group of 37 patients of similar age treated in 1991-1994. The baseline characteristics, procedural results, and hospital outcome were obtained from a prospectively designed interventional database at a busy single-center program. RESULTS: There was no significant difference in hospital survival between the two groups of patients treated in 1997-1998 although there was a trend toward higher mortality in the octogenarian group. Length of stay and use of intra-aortic balloon pumps were greater in the octogenarian group. When the results in octogenarians treated in 1997-1998 were compared with the group of 37 patients treated in 1991-1994, the hospital mortality declined from 27 to 10% (p = 0.05). CONCLUSIONS: There has been improvement in hospital mortality over the past decade for patients aged > or = 80 years treated with primary infarct intervention. Hospital resources and length of stay are greater for the octogenarian group. Ongoing research studies are comparing the results of thrombolytic therapy and primary intervention in aged patients.


Assuntos
Infarto do Miocárdio/cirurgia , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Seguimentos , Mortalidade Hospitalar , Humanos , Tempo de Internação/estatística & dados numéricos , Masculino , Infarto do Miocárdio/mortalidade , Avaliação de Resultados em Cuidados de Saúde/estatística & dados numéricos , Índice de Gravidade de Doença , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...