Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 250
Filtrar
1.
BMC Pediatr ; 24(1): 315, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38714956

RESUMO

BACKGROUND: Ultrasound (US) is often the first method used to look for brain or cerebrospinal fluid (CSF) space pathologies. Knowledge of normal CSF width values is essential. Most of the available US normative values were established over 20 years ago, were obtained with older equipment, and cover only part of the age spectrum that can be examined by cranial US. This prospective study aimed to determine the normative values of the widths of the subarachnoid and internal CSF spaces (craniocortical, minimal and maximal interhemispheric, interventricular, and frontal horn) for high-resolution linear US probes in neurologically healthy infants and children aged 0-19 months and assess whether subdural fluid collections can be delineated. METHODS: Two radiologists measured the width of the CSF spaces with a conventional linear probe and an ultralight hockey-stick probe in neurologically healthy children not referred for cranial or spinal US. RESULTS: This study included 359 neurologically healthy children (nboys = 178, 49.6%; ngirls = 181, 50.4%) with a median age of 46.0 days and a range of 1-599 days. We constructed prediction plots, including the 5th, 50th, and 95th percentiles, and an interactive spreadsheet to calculate normative values for individual patients. The measurements of the two probes and the left and right sides did not differ, eliminating the need for separate normative values. No subdural fluid collection was detected. CONCLUSION: Normative values for the widths of the subarachnoid space and the internal CSF spaces are useful for evaluating intracranial pathology, especially when determining whether an increase in the subarachnoid space width is abnormal.


Assuntos
Espaço Subaracnóideo , Ultrassonografia , Humanos , Lactente , Estudos Prospectivos , Masculino , Feminino , Valores de Referência , Recém-Nascido , Ultrassonografia/métodos , Espaço Subaracnóideo/diagnóstico por imagem , Líquido Cefalorraquidiano/diagnóstico por imagem
2.
Diagnostics (Basel) ; 14(9)2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38732301

RESUMO

The study aimed to investigate the feasibility of attenuation imaging (ATI) measurements using a linear probe on healthy volunteers and compare measurements with the conventional convex probe. Attenuation imaging measurements of the liver tissue were taken using ultrasound with a convex and a linear probe in 33 volunteers by two examining doctors, and the measurements were repeated 4-5 weeks later by one of them. The ATI values for the linear probe were in the range of the values for the convex probe for both examiners. Measurements did not change significantly for 32 out of 33 volunteers after 4-5 weeks when using the linear probe. The size of the region of interest (ROI) only impacted the ATI values for the convex probe; it did not affect the values taken with the linear probe. Healthy volunteers were measured, and their attenuation values were compared to those from a convex probe, commonly used in steatosis evaluation. When both probes were positioned in the same liver area, they showed good agreement in attenuation values, though depth significantly affected the measurements, with both probes providing different values at different depths. The study's results aligned with previous research using the same system. Operator A and B's results were compared, demonstrating similar ranges of values for both probes. The linear probe has been demonstrated to allow for superficial measurements and attain ATI values in line with that of the convex probe in the liver.

4.
J Rheumatol ; 51(3): 270-276, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38302169

RESUMO

OBJECTIVE: Mean lung attenuation, skewness, and kurtosis are histogram-based densitometry variables that quantify systemic sclerosis-associated interstitial lung disease (SSc-ILD) and were recently merged into a computerized integrated index (CII). Our work tested the CII in low-dose 9-slice (reduced) and standard high-resolution computed tomography (CT) scans to evaluate extensive SSc-ILD and predict mortality. METHODS: CT scans from patients with SSc-ILD were assessed using the software Horos to compute standard and reduced CIIs. Extensive ILD was determined following the Goh staging system. The association between CIIs and extensive ILD was analyzed with a generalized estimating equation regression model, the predictive ability of CIIs by the area under the receiver-operation characteristic curve (AUC), and the association between CIIs and death by Kaplan-Meier analysis. RESULTS: Among 243 patients with standard and reduced CT scans available, 157 CT scans from 119 patients with SSc-ILD constituted the derivation cohort. The validation cohort included 116 standard and 175 reduced CT scans. Both CIIs from standard (odds ratio [OR] 0.53, 95% CI 0.37-0.75; AUC 0.77, 95% CI 0.68-0.87) and reduced CT scans (OR 0.54, 95% CI 0.35-0.82; AUC 0.78, 95% CI 0.70-0.87) were significantly associated with extensive ILD. A threshold of CII ≤ -0.96 for standard CT scans and CII ≤ -1.85 for reduced CT scans detected extensive ILD with high sensitivity in both derivation and validation cohorts. Extensive ILD according to Goh staging (OR 2.94, 95% CI 1.10-7.82) and standard CII ≤ -0.96 (OR 1.78, 95% CI 1.24-2.56) significantly predicted mortality; a marginal P value was observed for reduced CII ≤ -1.85 (OR 1.27, 95% CI 0.93-1.75). CONCLUSION: Thresholds for both standard and reduced CII to identify extensive ILD were developed and validated, with an additional association with mortality. CIIs might help in clinical practice when radiology expertise is missing.


Assuntos
Doenças Pulmonares Intersticiais , Escleroderma Sistêmico , Humanos , Doenças Pulmonares Intersticiais/diagnóstico por imagem , Doenças Pulmonares Intersticiais/etiologia , Escleroderma Sistêmico/complicações , Escleroderma Sistêmico/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Estimativa de Kaplan-Meier , Densitometria
5.
Diagnostics (Basel) ; 14(3)2024 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-38337786

RESUMO

There have been studies showing attenuation imaging (ATI) with ultrasound as an approach to diagnose liver diseases such as steatosis or cirrhosis. So far, this technique has only been used on a convex probe. The goal of the study was to investigate the feasibility of ATI measurements using the linear array on a canon Aplio i800 scanner on certified phantoms. Three certified liver tissue attenuation phantoms were measured in five different positions using a linear probe. The effects of positioning and depth were explored and compared. The values were compared to the certified expected value for each phantom as well as the different measurement values for each measurement position. The ATI measurements on phantoms showed significant effect for the different probe positions and region of interest (ROI) depths. Values taken in the center with the probe perpendicular to the phantom were closest to certified values. Median values at 2.5-4.5 cm depth for phantoms 1 and 2 and 0.5-2.5 cm for phantom 3 were comparable with certified values. Measurements taken at a depth greater than 6 cm in any position were the least representative of the certified values (p-value < 0.01) and had the widest range throughout the different sessions. ATI measurements can be performed with the linear probe in phantoms; however, careful consideration should be given to depth dependency, as it can significantly affect measurement values. Remaining measurements at various depths within the 0.5-6.0 cm range showed deviation from the certified values of approximately 25%.

6.
Curr Probl Diagn Radiol ; 53(2): 246-251, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38290903

RESUMO

BACKGROUND: Have you ever been in the trenches of a complicated study only to be interrupted by a not-so urgent phone-call? We were, repeatedly- unfortunately. PURPOSE: To increase productivity of radiologists by quantifying the main source of interruptions (phone-calls) to the workflow of radiologists, and too assess the implemented solution. MATERIALS AND METHODS: To filter calls to the radiology consultant on duty, we introduced an automatic voicemail and custom call redirection system. Thus, instead of directly speaking with radiology consultants, clinicians were to first categorize their request and dial accordingly: 1. Inpatient requests, 2. Outpatient requests, 3. Directly speak with the consultant radiologist. Inpatient requests (1) and outpatient requests (2) were forwarded to MRI technologists or clerks, respectively. Calls were monitored in 15-minute increments continuously for an entire year (March 2022 until and including March 2023). Subsequently, both the frequency and category of requests were assessed. RESULTS: 4803 calls were recorded in total: 3122 (65 %) were forwarded to a radiologist on duty. 870 (18.11 %) concerned inpatients, 274 (5.70 %) outpatients, 430 (8.95 %) dialed the wrong number, 107 (2.23 %) made no decision. Throughout the entire year the percentage of successfully avoided interruptions was relatively stable and fluctuated between low to high 30 % range (Mean per month 35 %, Median per month 34.45 %). CONCLUSIONS: This is the first analysis of phone-call interruptions to consultant radiologists in an imaging department for 12 continuous months. More than 35 % of requests did not require the input of a specialist trained radiologist. Hence, installing an automated voicemail and custom call redirection system is a sustainable and simple solution to reduce phone-call interruptions by on average 35 % in radiology departments. This solution was well accepted by referring clinicians. The installation required a one-time investment of only 2h and did not cost any money.


Assuntos
Serviço Hospitalar de Radiologia , Radiologia , Humanos , Radiologistas , Radiografia , Telefone
7.
Invest Radiol ; 2024 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-38193782

RESUMO

OBJECTIVES: The aim of this study was to evaluate the optimal energy level of virtual monoenergetic images (VMIs) from photon-counting detector computed tomography (CT) for the detection of liver lesions as a function of phantom size and radiation dose. MATERIALS AND METHODS: An anthropomorphic abdominal phantom with liver parenchyma and lesions was imaged on a dual-source photon-counting detector CT at 120 kVp. Five hypoattenuating lesions with a lesion-to-background contrast difference of -30 HU and -45 HU and 3 hyperattenuating lesions with +30 HU and +90 HU were used. The lesion diameter was 5-10 mm. Rings of fat-equivalent material were added to emulate medium- or large-sized patients. The medium size was imaged at a volume CT dose index of 5, 2.5, and 1.25 mGy and the large size at 5 and 2.5 mGy, respectively. Each setup was imaged 10 times. For each setup, VMIs from 40 to 80 keV at 5 keV increments were reconstructed with quantum iterative reconstruction at a strength level of 4 (QIR-4). Lesion detectability was measured as area under the receiver operating curve (AUC) using a channelized Hotelling model observer with 10 dense differences of Gaussian channels. RESULTS: Overall, highest detectability was found at 65 and 70 keV for both hypoattenuating and hyperattenuating lesions in the medium and large phantom independent of radiation dose (AUC range, 0.91-1.0 for the medium and 0.94-0.99 for the large phantom, respectively). The lowest detectability was found at 40 keV irrespective of the radiation dose and phantom size (AUC range, 0.78-0.99). A more pronounced reduction in detectability was apparent at 40-50 keV as compared with 65-75 keV when radiation dose was decreased. At equal radiation dose, detection as a function of VMI energy differed stronger for the large size as compared with the medium-sized phantom (12% vs 6%). CONCLUSIONS: Detectability of hypoattenuating and hyperattenuating liver lesions differed between VMI energies for different phantom sizes and radiation doses. Virtual monoenergetic images at 65 and 70 keV yielded highest detectability independent of phantom size and radiation dose.

8.
J Cardiovasc Dev Dis ; 10(11)2023 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-37998500

RESUMO

BACKGROUND: Pulmonary endarterectomy (PEA) is the treatment of choice for patients with chronic thromboembolic pulmonary hypertension (CTEPH) with accessible lesions. Breathing pure oxygen (hyperoxia) during right heart catheterization (RHC) allows for the calculation of the right-to-left shunt fraction (Qs/Qt). In the absence of intracardiac shunt, Qs/Qt can be used as a marker of ventilation-perfusion mismatch in patients with CTEPH. This study involved investigating Qs/Qt after PEA and its relation to other disease-specific outcomes. STUDY DESIGN AND METHODS: This study is a retrospective study that focuses on patients with operable CTEPH who had Qs/Qt assessment during RHC before and 1 year after PEA. Additionally, 6 min walking distance (6MWD), WHO functional class (WHO-FC), and NT-proBNP were assessed to calculate a four-strata risk score. RESULTS: Overall, 16 patients (6 females) with a median age of 66 years (quartiles 55; 74) were included. After PEA, an improvement in mean pulmonary artery pressure (38 [32; 41] to 24 [18; 28] mmHg), pulmonary vascular resistance (5.7 [4.0; 6.8] to 2.5 [1.4; 3.8] WU), oxygen saturation (92 [88; 93]% to 94 [93; 95]%), WHO-FC, and risk score was observed (all p < 0.05). No improvement in median Qs/Qt could be detected (13.7 [10.0; 17.5]% to 13.0 [11.2; 15.6]%, p = 0.679). A total of 7 patients with improved Qs/Qt had a significant reduction in risk score compared to those without improved Qs/Qt. CONCLUSION: PEA did not alter Qs/Qt assessed after 1 year in operable CTEPH despite an improvement in hemodynamics and risk score, potentially indicating a persistent microvasculopathy. In patients whose shunt fraction improved with PEA, the reduced shunt was associated with an improvement in risk score.

9.
Invest Radiol ; 2023 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-37812482

RESUMO

OBJECTIVES: With the introduction of clinical photon-counting detector computed tomography (PCD-CT) and its novel reconstruction techniques, a quantitative investigation of different acquisition and reconstruction settings is necessary to optimize clinical acquisition protocols for metal artifact reduction. MATERIALS AND METHODS: A multienergy phantom was scanned on a clinical dual-source PCD-CT (NAEOTOM Alpha; Siemens Healthcare GmbH) with 4 different central inserts: water-equivalent plastic, aluminum, steel, and titanium. Acquisitions were performed at 120 kVp and 140 kVp (CTDIvol 10 mGy) and reconstructed as virtual monoenergetic images (VMIs; 110-150 keV), as T3D, and with the standard reconstruction "none" (70 keV VMI) using different reconstruction kernels (Br36, Br56) and with as well as without iterative metal artifact reduction (iMAR). Metal artifacts were quantified, calculating relative percentages of metal artifacts. Mean CT numbers of an adjacent water-equivalent insert and different tissue-equivalent inserts were evaluated, and eccentricity of metal rods was measured. Repeated-measures analysis of variance was performed for statistical analysis. RESULTS: Metal artifacts were most prevalent for the steel insert (12.6% average artifacts), followed by titanium (4.2%) and aluminum (1.0%). The strongest metal artifact reduction was noted for iMAR (with iMAR: 1.4%, without iMAR: 10.5%; P < 0.001) or VMI (VMI: 110 keV 2.6% to 150 keV 3.3%, T3D: 11.0%, and none: 16.0%; P < 0.001) individually, with best results when combining iMAR and VMI at 110 keV (1.2%). Changing acquisition tube potential (120 kV: 6.6%, 140 kV: 5.2%; P = 0.33) or reconstruction kernel (Br36: 5.5%, Br56: 6.4%; P = 0.17) was less effective. Mean CT numbers and standard deviations were significantly affected by iMAR (with iMAR: -3.0 ± 21.5 HU, without iMAR: -8.5 ± 24.3 HU; P < 0.001), VMI (VMI: 110 keV -3.6 ± 21.6 HU to 150 keV -1.4 ± 21.2 HU, T3D: -11.7 ± 23.8 HU, and none: -16.9 ± 29.8 HU; P < 0.001), tube potential (120 kV: -4.7 ± 22.8 HU, 140 kV: -6.8 ± 23.0 HU; P = 0.03), and reconstruction kernel (Br36: -5.5 ± 14.2 HU, Br56: -6.8 ± 23.0 HU; P < 0.001). Both iMAR and VMI improved quantitative CT number accuracy and metal rod eccentricity for the steel rod, but iMAR was of limited effectiveness for the aluminum rod. CONCLUSIONS: For metal artifact reduction in PCD-CT, a combination of iMAR and VMI at 110 keV demonstrated the strongest artifact reduction of the evaluated options, whereas the impact of reconstruction kernel and tube potential was limited.

10.
J Clin Med ; 12(18)2023 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-37762713

RESUMO

This pilot study conducted in Switzerland aims to assess the implementation, execution, and performance of low-dose CT lung cancer screening (LDCT-LCS). With lung cancer being the leading cause of cancer-related deaths in Switzerland, the study seeks to explore the potential impact of screening on reducing mortality rates. However, initiating a lung cancer screening program poses challenges and depends on country-specific factors. This prospective study, initiated in October 2018, enrolled participants meeting the National Lung Cancer Study criteria or a lung cancer risk above 1.5% according to the PLCOm2012 lung cancer risk-model. LDCT scans were assessed using Lung-RADS. Enrollment and follow-up are ongoing. To date, we included 112 participants, with a median age of 62 years (IQR 57-67); 42% were female. The median number of packs smoked each year was 45 (IQR 38-57), and 24% had stopped smoking before enrollment. The mean PLCOm2012 was 3.7% (±2.5%). We diagnosed lung cancer in 3.6% of participants (95%, CI:1.0-12.1%), with various stages, all treated with curative intent. The recall rate for intermediate results (Lung-RADS 3,4a) was 15%. LDCT-LCS in Switzerland, using modified inclusion criteria, is feasible. Further analysis will inform the potential implementation of a comprehensive lung cancer screening program in Switzerland.

11.
J Magn Reson Imaging ; 2023 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-37732541

RESUMO

BACKGROUND: Detection of pulmonary perfusion defects is the recommended approach for diagnosing chronic thromboembolic pulmonary hypertension (CTEPH). This is currently achieved in a clinical setting using scintigraphy. Phase-resolved functional lung (PREFUL) magnetic resonance imaging (MRI) is an alternative technique for evaluating regional ventilation and perfusion without the use of ionizing radiation or contrast media. PURPOSE: To assess the feasibility and image quality of PREFUL-MRI in a multicenter setting in suspected CTEPH. STUDY TYPE: This is a prospective cohort sub-study. POPULATION: Forty-five patients (64 ± 16 years old) with suspected CTEPH from nine study centers. FIELD STRENGTH/SEQUENCE: 1.5 T and 3 T/2D spoiled gradient echo/bSSFP/T2 HASTE/3D MR angiography (TWIST). ASSESSMENT: Lung signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were compared between study centers with different MRI machines. The contrast between normally and poorly perfused lung areas was examined on PREFUL images. The perfusion defect percentage calculated using PREFUL-MRI (QDPPREFUL ) was compared to QDP from the established dynamic contrast-enhanced MRI technique (QDPDCE ). Furthermore, QDPPREFUL was compared between a patient subgroup with confirmed CTEPH or chronic thromboembolic disease (CTED) to other clinical subgroups. STATISTICAL TESTS: t-Test, one-way analysis of variance (ANOVA), Pearson's correlation. Significance level was 5%. RESULTS: Significant differences in lung SNR and CNR were present between study centers. However, PREFUL perfusion images showed a significant contrast between normally and poorly perfused lung areas (mean delta of normalized perfusion -4.2% SD 3.3) with no differences between study sites (ANOVA: P = 0.065). QDPPREFUL was significantly correlated with QDPDCE (r = 0.66), and was significantly higher in 18 patients with confirmed CTEPH or CTED (57.9 ± 12.2%) compared to subgroups with other causes of PH or with excluded PH (in total 27 patients with mean ± SD QDPPREFUL = 33.9 ± 17.2%). DATA CONCLUSION: PREFUL-MRI could be considered as a non-invasive method for imaging regional lung perfusion in multicenter studies. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY: Stage 1.

12.
Eur J Radiol ; 166: 110981, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37478655

RESUMO

PURPOSE: To assess image quality and detectability of interstitial lung changes using multiple radiation doses from the same chest CT scan of patients with suspected interstitial lung disease (ILD). METHOD: Retrospective study of consecutive adult patients with suspected ILD receiving unenhanced chest CT as single-energy dual-source acquisition at 100 kVp (Dual-split mode). 67% and 33% of the overall tube current time product were assigned to tube A and B, respectively. 100%-dose was 2.34 ± 0.97 mGy. Five different radiation doses (100%, 67%, 45%, 39%, 33%) were reconstructed from this single acquisition using linear-blending technique. Two blinded radiologists assessed reticulations, ground-glass opacities (GGO) and honeycombing as well as subjective image noise. Percentage agreement (PA) as compared to 100%-dose were calculated. Non-parametric statistical tests were used. RESULTS: A total of 228 patients were included (61.2 ± 14.6 years,146 female). PA was highest for honeycombing (>96%) and independent of dose reduction (P > 0.8). PA for reticulations and GGO decreased when reducing the radiation dose from 100% to 67% for both readers (reticulations: 83.3% and 93.9%; GGO: 87.7% and 79.8% for reader 1 and 2, respectively). Additional dose reduction did not significantly change PA for both readers (all P > 0.05). Subjective image noise increased with decreasing radiation dose (Spearman Rho of ρ = 0.34 and ρ = 0.53 for reader 1 and 2, respectively, P < 0.001). CONCLUSIONS: Radiation dose reduction had a stronger impact on subtle interstitial lung changes. Detectability decreased with initial dose reduction indicating that a minimum dose is needed to maintain diagnostic accuracy in chest CT for suspected ILD.


Assuntos
Doenças Pulmonares Intersticiais , Tomografia Computadorizada por Raios X , Adulto , Humanos , Feminino , Estudos Retrospectivos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Doenças Pulmonares Intersticiais/diagnóstico por imagem , Pulmão/diagnóstico por imagem
13.
Ultrasound Med Biol ; 49(8): 1742-1759, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37156674

RESUMO

OBJECTIVE: The aim of the work described here was to investigate the relative contribution of confounding factors on liver shear wave speed (SWS) and shear wave dispersion slope (SWDS) measurements in three certified phantoms using a Canon Aplio clinical ultrasound scanner. METHODS: A Canon Aplio i800 i-series ultrasound system (Canon Medical Systems Corporation, Otawara, Tochigi, Japan) with i8CX1 convex array (center frequency = 4 MHz) was used to examine dependencies caused by the depth, width and height of the acquisition box (AQB), the depth and size of the region of interest (ROI), the AQB angle and the pressure of the ultrasound probe on the surface of the phantom. RESULTS: Results revealed that depth is the most significant confounder in both SWS and SWDS measurements. AQB angle, height and width and ROI size exhibited minimal confounding effects on measurements. For SWS, the most consistent measurement depth is when the top of the AQB is placed between 2 and 4 cm, and the ROI is located between 3 and 7 cm deep. For SWDS, results indicate that measurement values significantly decrease with depth from the surface of the phantom until approximately 7 cm deep, and consequently no stable area of AQB placement or ROI depth exists. CONCLUSION: In contrast to SWS, the same ideal acquisition depth range cannot necessarily be applied to SWDS measurements because of a significant depth dependency.


Assuntos
Técnicas de Imagem por Elasticidade , Técnicas de Imagem por Elasticidade/métodos , Ultrassonografia/métodos , Fígado/diagnóstico por imagem , Imagens de Fantasmas , Transdutores
14.
Diagnostics (Basel) ; 13(9)2023 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-37175007

RESUMO

(1) Background: Lung tissue involvement is frequently observed in acute COVID-19. However, it is unclear whether CT findings at follow-up are associated with persisting respiratory symptoms after initial mild or moderate infection. (2) Methods: Chest CTs of patients with persisting respiratory symptoms referred to the post-COVID-19 outpatient clinic were reassessed for parenchymal changes, and their potential association was evaluated. (3) Results: A total of 53 patients (31 female) with a mean (SD) age of 46 (13) years were included, of whom 89% had mild COVID-19. Median (quartiles) time from infection to CT was 139 (86, 189) days. Respiratory symptoms were dyspnea (79%), cough (42%), and thoracic pain (64%). Furthermore, 30 of 53 CTs showed very discrete and two CTs showed medium parenchymal abnormalities. No severe findings were observed. Mosaic attenuation (40%), ground glass opacity (2%), and fibrotic-like changes (25%) were recorded. No evidence for an association between persisting respiratory symptoms and chest CT findings was found. (4) Conclusions: More than half of the patients with initially mild or moderate infection showed findings on chest CT at follow-up. Respiratory symptoms, however, were not related to any chest CT finding. We, therefore, do not suggest routine chest CT follow-up in this patient group if no other indications are given.

15.
Diagnostics (Basel) ; 13(5)2023 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-36900133

RESUMO

OBJECTIVES: Measurement location and patient state can impact noninvasive liver assessment and change clinical staging in ultrasound examinations. Research into differences exists for Shear Wave Speed (SWS) and Attenuation Imaging (ATI), but not for Shear Wave Dispersion (SWD). The aim of this study is to assess the effect of breathing phase, liver lobe, and prandial state on SWS, SWD, and ATI ultrasound measurements. METHODS: Two experienced examiners performed SWS, SWD, and ATI measurements in 20 healthy volunteers using a Canon Aplio i800 system. Measurements were taken in the recommended condition (right lobe, following expiration, fasting state), as well as (a) following inspiration, (b) in the left lobe, and (c) in a nonfasting state. RESULTS: SWS and SWD measurements were strongly correlated (r = 0.805, p < 0.001). Mean SWS was 1.34 ± 0.13 m/s in the recommended measurement position and did not change significantly under any condition. Mean SWD was 10.81 ± 2.05 m/s/kHz in the standard condition and significantly increased to 12.18 ± 1.41 m/s/kHz in the left lobe. Individual SWD measurements in the left lobe also had the highest average coefficient of variation (19.68%). No significant differences were found for ATI. CONCLUSION: Breathing and prandial state did not significantly affect SWS, SWD, and ATI values. SWS and SWD measurements were strongly correlated. SWD measurements in the left lobe showed a higher individual measurement variability. Interobserver agreement was moderate to good.

16.
Diagnostics (Basel) ; 13(4)2023 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-36832118

RESUMO

BACKGROUND: To assess the impact of the lung cancer screening protocol recommended by the European Society of Thoracic Imaging (ESTI) on nodule diameter, volume, and density throughout different computed tomography (CT) scanners. METHODS: An anthropomorphic chest phantom containing fourteen different-sized (range 3-12 mm) and CT-attenuated (100 HU, -630 HU and -800 HU, termed as solid, GG1 and GG2) pulmonary nodules was imaged on five CT scanners with institute-specific standard protocols (PS) and the lung cancer screening protocol recommended by ESTI (ESTI protocol, PE). Images were reconstructed with filtered back projection (FBP) and iterative reconstruction (REC). Image noise, nodule density and size (diameter/volume) were measured. Absolute percentage errors (APEs) of measurements were calculated. RESULTS: Using PE, dosage variance between different scanners tended to decrease compared to PS, and the mean differences were statistically insignificant (p = 0.48). PS and PE(REC) showed significantly less image noise than PE(FBP) (p < 0.001). The smallest size measurement errors were noted with volumetric measurements in PE(REC) and highest with diametric measurements in PE(FBP). Volume performed better than diameter measurements in solid and GG1 nodules (p < 0.001). However, in GG2 nodules, this could not be observed (p = 0.20). Regarding nodule density, REC values were more consistent throughout different scanners and protocols. CONCLUSION: Considering radiation dose, image noise, nodule size, and density measurements, we fully endorse the ESTI screening protocol including the use of REC. For size measurements, volume should be preferred over diameter.

17.
Eur Heart J Case Rep ; 7(2): ytad057, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36824364

RESUMO

Background: The use of pulmonary vein (PV) radiofrequency ablation for atrial fibrillation (AF) treatment may be complicated by PV stenosis or occlusion. A common curative treatment for symptomatic patients is a transcatheter intervention, including percutaneous transluminal balloon angioplasty and stent implantation. Stent implantation itself, however, can be complicated by in-stent stenosis. Case summary: A 26-year-old man presented with worsening exertional dyspnoea due to a total occlusion of both left PVs after the isolation of two PVs for AF. Chest computed tomography (CT) showed chest asymmetry and consolidation of the left lung. The patient was treated with balloon angioplasty and stent placement of both left PVs, resulting in improvement of symptoms, walking distance, and increase in lung space volume by 120 mL based on CT-based volumetry. Ten months later, the patient experienced a recurrence of similar symptoms. A high grade in stent restenosis of the upper left PV and moderate in stent restenosis of the lower PV were diagnosed and treated with angioplasty. The patient was discharged from the hospital in good clinical condition 3 days after the intervention. Discussion: Non-specific symptoms of PV stenosis or occlusion, such as shortness of breath, fatigue, flu-like symptoms, reduced physical performance, and haemoptysis delay the diagnosis. If unusual symptoms appear abruptly after PV isolation, a PV stenosis should be considered. In this case, we describe for the first time a partially reversible consolidation of lung parenchyma following the revascularization of both PVs.

18.
Medicine (Baltimore) ; 102(7): e32917, 2023 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-36800631

RESUMO

A major risk factor to develop active tuberculosis (TB) is the infection with the human immunodeficiency virus (HIV). Chest radiography is the first-line imaging modality used to rule out TB. Coinfected individuals present often with atypical imaging patterns, due to the immunosuppression caused by the virus, making diagnosis difficult. In this prospective observational study 268 TB and HIV coinfected patients were included. During a follow-up period of 24 weeks, the predominant patterns on chest radiography were analyzed and compared to the cluster of differentiation 4 (CD4) count under antiretroviral and anti-TB therapy. Patients with low CD4 counts (<200 cells//µL) showed more often lymphadenopathy (62% vs 38%;P = .08) and a miliary pattern (64% vs 36%;P = .04) but less likely cavitation (32% vs 68%;P = .008) or consolidation (47% vs 63%;P = .002) compared to individuals with higher CD4 counts. Over the follow-up period, partial response to therapy was the most frequent radiological evolution (62%), mainly accompanied by an increase of CD4 cells (92%). Patients with a decrease in CD4 count mostly presented with a worsening in radiological findings (53%). Radiographic TB manifestation correlated with the immune status of patients coinfected with HIV. Low CD4 counts often showed atypical manifestation.


Assuntos
Infecções Oportunistas Relacionadas com a AIDS , Síndrome da Imunodeficiência Adquirida , Infecções por HIV , Tuberculose , Humanos , Síndrome da Imunodeficiência Adquirida/complicações , Infecções Oportunistas Relacionadas com a AIDS/diagnóstico por imagem , Infecções Oportunistas Relacionadas com a AIDS/complicações , Contagem de Linfócito CD4 , Infecções por HIV/complicações , HIV-1 , Tuberculose/complicações , Tuberculose/diagnóstico por imagem
19.
Eur Radiol ; 33(7): 5077-5086, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36729173

RESUMO

This statement from the European Society of Thoracic imaging (ESTI) explains and summarises the essentials for understanding and implementing Artificial intelligence (AI) in clinical practice in thoracic radiology departments. This document discusses the current AI scientific evidence in thoracic imaging, its potential clinical utility, implementation and costs, training requirements and validation, its' effect on the training of new radiologists, post-implementation issues, and medico-legal and ethical issues. All these issues have to be addressed and overcome, for AI to become implemented clinically in thoracic radiology. KEY POINTS: • Assessing the datasets used for training and validation of the AI system is essential. • A departmental strategy and business plan which includes continuing quality assurance of AI system and a sustainable financial plan is important for successful implementation. • Awareness of the negative effect on training of new radiologists is vital.


Assuntos
Inteligência Artificial , Radiologia , Humanos , Radiologia/métodos , Radiologistas , Radiografia Torácica , Sociedades Médicas
20.
Radiol Med ; 128(2): 149-159, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36598734

RESUMO

PURPOSE: To compare the positive predictive values (PPVs) of BI-RADS categories used to assess pure mammographic calcifications in women with and without a previous history of breast cancer (PHBC). MATERIALS AND METHODS: In this retrospective study, all consecutive pure mammographic calcifications (n = 320) undergoing a stereotactic biopsy between 2016 and 2018 were identified. Mammograms were evaluated in consensus by two radiologists according to BI-RADS and blinded to patient history and pathology results. Final pathologic results were used as the standard of reference. PPV of BI-RADS categories were compared between the two groups. Data were evaluated using standard statistics, Mann-Whitney U tests and Chi-square tests. RESULTS: Two hundred sixty-eight patients (274 lesions, median age 54 years, inter-quartile range, 50-65 years) with a PHBC (n = 46) and without a PHBC (n = 222) were included. Overall PPVs were the following: BI-RADS 2, 0% (0 of 56); BI-RADS 3, 9.1% (1 of 11); BI-RADS 4a, 16.2% (6 of 37); BI-RADS 4b, 37.5% (48 of 128); BI-RADS 4c, 47.3% (18 of 38) and BI-RADS 5, 100% (4 of 4). The PPV of BI-RADS categories was similar in patients with and without a PHBC (P = .715). Calcifications were more often malignant in patients with a PHBC older than 10 years (47.3%, 9 of 19) compared to 1-2 years (25%, 1 of 4), 2-5 years (20%, 2 of 10) and 5-10 years (0%, of 13) from the first breast cancer (P = .005). CONCLUSION: PPV of mammographic calcifications is similar in women with or without PHBC when BI-RADS classification is strictly applied. A higher risk of malignancy was observed in patients with a PHBC longer than 10 years.


Assuntos
Neoplasias da Mama , Calcinose , Feminino , Humanos , Pessoa de Meia-Idade , Neoplasias da Mama/patologia , Estudos Retrospectivos , Mamografia/métodos , Biópsia , Valor Preditivo dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...