Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
Front Cardiovasc Med ; 11: 1359715, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38596691

RESUMO

Background: A reduced left atrial (LA) strain correlates with the presence of atrial fibrillation (AF). Conventional atrial strain analysis uses two-dimensional (2D) imaging, which is, however, limited by atrial foreshortening and an underestimation of through-plane motion. Retrospective gated computed tomography (RGCT) produces high-fidelity three-dimensional (3D) images of the cardiac anatomy throughout the cardiac cycle that can be used for estimating 3D mechanics. Its feasibility for LA strain measurement, however, is understudied. Aim: The aim of this study is to develop and apply a novel workflow to estimate 3D LA motion and calculate the strain from RGCT imaging. The utility of global and regional strains to separate heart failure in patients with reduced ejection fraction (HFrEF) with and without AF is investigated. Methods: A cohort of 30 HFrEF patients with (n = 9) and without (n = 21) AF underwent RGCT prior to cardiac resynchronisation therapy. The temporal sparse free form deformation image registration method was optimised for LA feature tracking in RGCT images and used to estimate 3D LA endocardial motion. The area and fibre reservoir strains were calculated over the LA body. Universal atrial coordinates and a human atrial fibre atlas enabled the regional strain calculation and the fibre strain calculation along the local myofibre orientation, respectively. Results: It was found that global reservoir strains were significantly reduced in the HFrEF + AF group patients compared with the HFrEF-only group patients (area strain: 11.2 ± 4.8% vs. 25.3 ± 12.6%, P = 0.001; fibre strain: 4.5 ± 2.0% vs. 15.2 ± 8.8%, P = 0.001), with HFrEF + AF patients having a greater regional reservoir strain dyssynchrony. All regional reservoir strains were reduced in the HFrEF + AF patient group, in whom the inferior wall strains exhibited the most significant differences. The global reservoir fibre strain and LA volume + posterior wall reservoir fibre strain exceeded LA volume alone and 2D global longitudinal strain (GLS) for AF classification (area-under-the-curve: global reservoir fibre strain: 0.94 ± 0.02, LA volume + posterior wall reservoir fibre strain: 0.95 ± 0.02, LA volume: 0.89 ± 0.03, 2D GLS: 0.90 ± 0.03). Conclusion: RGCT enables 3D LA motion estimation and strain calculation that outperforms 2D strain metrics and LA enlargement for AF classification. Differences in regional LA strain could reflect regional myocardial properties such as atrial fibrosis burden.

2.
Heart Rhythm ; 20(11): 1481-1488, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37453603

RESUMO

BACKGROUND: The WiSE-CRT System (EBR systems, Sunnyvale, CA) permits leadless left ventricular pacing. Currently, no intraprocedural guidance is used to target optimal electrode placement while simultaneously guiding acoustic transmitter placement in close proximity to the electrode to ensure adequate power delivery. OBJECTIVE: The purpose of this study was to assess the use of computed tomography (CT) anatomy, dynamic perfusion and mechanics, and predicted activation pattern to identify both the optimal electrode and transmitter locations. METHODS: A novel CT protocol was developed using preprocedural imaging and simulation to identify target segments (TSs) for electrode implantation, with late electrical and mechanical activation, with ≥5 mm wall thickness without perfusion defects. Modeling of the acoustic intensity from different transmitter implantation sites to the TSs was used to identify the optimal transmitter location. During implantation, TSs were overlaid on fluoroscopy to guide optimal electrode location that were evaluated by acute hemodynamic response (AHR) by measuring the maximal rate of left ventricular pressure rise with biventricular pacing. RESULTS: Ten patients underwent the implantation procedure. The transmitter could be implanted within the recommended site on the basis of preprocedural analysis in all patients. CT identified a mean of 4.8 ± 3.5 segments per patient with wall thickness < 5 mm. During electrode implantation, biventricular pacing within TSs resulted in a significant improvement in AHR vs non-TSs (25.5% ± 8.8% vs 12.9% ± 8.6%; P < .001). Pacing in CT-identified scar resulted in either failure to capture or minimal AHR improvement. The electrode was targeted to the TSs in all patients and was implanted in the TSs in 80%. CONCLUSION: Preprocedural imaging and modeling data with intraprocedural guidance can successfully guide WiSE-CRT electrode and transmitter implantation to allow optimal AHR and adequate power delivery.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Dispositivos de Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/terapia , Terapia de Ressincronização Cardíaca/métodos , Eletrodos , Tomografia Computadorizada por Raios X , Perfusão , Resultado do Tratamento , Ventrículos do Coração/diagnóstico por imagem
3.
Eur J Radiol ; 149: 110223, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35240412

RESUMO

OBJECTIVES: Objective evaluation of the extent of skeletal marrow involvement in multiple myeloma remains a clinical gap for CT. We aimed to develop a quantitative segmentation pipeline for dual energy CT and to assess whether quantified whole skeleton calcium-subtracted attenuation values correlate with biopsy-derived bone marrow infiltration in multiple myeloma. METHODS: Consecutive prospective patients with suspected/established myeloma underwent dual source CT from the skull vertex to proximal tibia. Whole skeleton segmentation was performed for 120 kVp-equivalent images as follows: following Hounsfield unit (HU) thresholding, a Chan-Vese morphological operation was implemented to generate a whole skeleton segmentation mask. This mask was then applied to corresponding whole skeleton material decomposition calcium-subtracted maps, generating whole skeleton HU values. Associations with biopsy-derived bone marrow plasma cell infiltration percentage were assessed with Spearman's rank correlation; significance was at 5%. RESULTS: 21 patients (12 females; median (IQR) 67 (61, 73) years) were included; 16 patients had osteolytic bone lesions; 15 patients underwent bone marrow biopsy. Segmentation and quantification were feasible in all patients. Median (IQR) of the average skeletal calcium-subtracted attenuation was -59.9 HU (-66.3, -51.8HU). There was a positive correlation with bone marrow plasma cell infiltration percentage (Spearman's rho: + 0.79, p < 0.001). CONCLUSION: Whole skeleton calcium-subtracted attenuation is associated with the degree of bone marrow infiltration by plasma cells, providing an objective measure of marrow involvement with the potential to allow earlier detection of disease.


Assuntos
Medula Óssea , Mieloma Múltiplo , Medula Óssea/diagnóstico por imagem , Medula Óssea/patologia , Cálcio , Feminino , Humanos , Mieloma Múltiplo/diagnóstico por imagem , Mieloma Múltiplo/patologia , Estudos Prospectivos , Esqueleto/patologia , Tomografia Computadorizada por Raios X/métodos
5.
J Cardiovasc Electrophysiol ; 32(3): 802-812, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33484216

RESUMO

BACKGROUND: Optimal positioning of the left ventricular (LV) lead is an important determinant of cardiac resynchronization therapy (CRT) response. OBJECTIVE: Evaluate the feasibility of intraprocedural integration of cardiac computed tomography (CT) to guide LV lead implantation for CRT upgrades. METHODS: Patients undergoing LV lead upgrade underwent ECG-gated cardiac CT dyssynchrony and LV scar assessment. Target American Heart Association segment selection was determined using latest non-scarred mechanically activating segments overlaid onto real-time fluoroscopy with image co-registration to guide optimal LV lead implantation. Hemodynamic validation was performed using a pressure wire in the LV cavity (dP/dtmax) ). RESULTS: 18 patients (male 94%, 55.6% ischemic cardiomyopathy) with RV pacing burden 60.0 ± 43.7% and mean QRS duration 154 ± 30 ms underwent cardiac CT. 10/10 ischemic patients had CT evidence of scar and these segments were excluded as targets. Seventeen out of 18 (94%) patients underwent successful LV lead implantation with delivery to the CT target segment in 15 out of 18 (83%) of patients. Acute hemodynamic response (dP/dtmax ≥ 10%) was superior with LV stimulation in CT target versus nontarget segments (83.3% vs. 25.0%; p = .012). Reverse remodeling at 6 months (LV end-systolic volume improvement ≥15%) occurred in 60% of subjects (4/8 [50.0%] ischemic cardiomyopathy vs. 5/7 [71.4%] nonischemic cardiomyopathy, p = .608). CONCLUSION: Intraprocedural integration of cardiac CT to guide optimal LV lead placement is feasible with superior hemodynamics when pacing in CT target segments and favorable volumetric response rates, despite a high proportion of patients with ischemic cardiomyopathy. Multicentre, randomized controlled studies are needed to evaluate whether intraprocedural integration of cardiac CT is superior to standard care.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Estudos de Viabilidade , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Humanos , Masculino , Tomografia , Tomografia Computadorizada por Raios X , Resultado do Tratamento
6.
Funct Imaging Model Heart ; 12738: 71-83, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35727914

RESUMO

Retrospective gated cardiac computed tomography (CCT) images can provide high contrast and resolution images of the heart throughout the cardiac cycle. Feature tracking in retrospective CCT images using the temporal sparse free-form deformations (TSFFDs) registration method has previously been optimised for the left ventricle (LV). However, there is limited work on optimising nonrigid registration methods for feature tracking in the left atria (LA). This paper systematically optimises the sparsity weight (SW) and bending energy (BE) as two hyperparameters of the TSFFD method to track the LA endocardium from end-diastole (ED) to end-systole (ES) using 10-frame retrospective gated CCT images. The effect of two different control point (CP) grid resolutions was also investigated. TSFFD optimisation was achieved using the average surface distance (ASD), directed Hausdorff distance (DHD) and Dice score between the registered and ground truth surface meshes and segmentations at ES. For baseline comparison, the configuration optimised for LV feature tracking gave errors across the cohort of 0.826 ± 0.172mm ASD, 5.882 ± 1.524mm DHD, and 0.912 ± 0.033 Dice score. Optimising the SW and BE hyperparameters improved the TSFFD performance in tracking LA features, with case specific optimisations giving errors across the cohort of 0.750 ± 0.144mm ASD, 5.096 ± 1.246mm DHD, and 0.919 ± 0.029 Dice score. Increasing the CP resolution and optimising the SW and BE further improved tracking performance, with case specific optimisation errors of 0.372 ± 0.051mm ASD, 2.739 ± 0.843mm DHD and 0.949 ± 0.018 Dice score across the cohort. We therefore show LA feature tracking using TSFFDs is improved through a chamber-specific optimised configuration.

8.
Acad Radiol ; 26(9): 1154-1163, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-30482626

RESUMO

RATIONALE AND OBJECTIVES: We assessed the value of iodine concentration (IC) as a perfusion-derived response marker for hepatocellular carcinoma (HCC) treated with transarterial chemoembolization (TACE) in comparison with volume perfusion computed tomography (VPCT) parameters. MATERIALS AND METHODS: Forty-one HCC lesions in 32 patients examined before and after TACE were analyzed retrospectively. VPCT-parameters were calculated and lesion iodine-maps were computed using subtraction of the baseline and the scan 7 seconds after aortic peak enhancement from the corresponding 80 kVp-VPCT data set. Modified RECIST was used as standard response criteria. Comparisons were performed using Student's t test for normal distributed data and Mann-Whitney U test for non-normal distributed data. Additionally, correlation analysis, receiver operating characteristics (ROC) and interreader agreement were assessed. RESULTS: In responding lesions, mean pre-TACE IC and blood flow (BF) were 131.2 mg/100 mL and 96.7 mL/100 mL/min, decreasing to IC 25.6 mg/100 mL (P < 0.001) and BF 28.5 mL/100 mL/min (P < 0.001) post-TACE. In nonresponding lesions, the values remained almost unchanged: pre-TACE: mean BF 79.3 mL/100 mL/min and mean IC 90.4 mg/100 mL; post-TACE: mean BF 71.3 mL/100 mL/min (n.s.) and mean IC 105.4 mg/100 mL (n.s.). Differences in IC-values revealed a high sensitivity/specificity of 96.7%/81.8%. IC and VPCT-parameters showed strong, positive correlations. Mean volume CT dose index for VPCT was 63.4 mGy and 4.9 mGy for iodine maps. CONCLUSION: Thus, IC is a meaningful perfusion marker for local therapy response monitoring in HCC that can be acquired with low radiation dose. This information is important for further therapy response applications using dual and single energy CT.


Assuntos
Carcinoma Hepatocelular/terapia , Quimioembolização Terapêutica/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Neoplasias Hepáticas/terapia , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Iodo , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão/métodos , Curva ROC , Fluxo Sanguíneo Regional , Critérios de Avaliação de Resposta em Tumores Sólidos , Estudos Retrospectivos
9.
Eur Radiol ; 29(6): 2868-2877, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30406312

RESUMO

OBJECTIVES: To retrospectively quantify liver iron content in haematological patients suspected of transfusional haemosiderosis using dual-energy CT (DECT) and correlate with serum ferritin levels and estimated quantity of transfused iron. METHODS: One hundred forty-seven consecutive dual-source dual-energy non-contrast chest-CTs in 110 haematologic patients intended primarily for exclusion of pulmonary infection between September 2016 and June 2017 were retrospectively evaluated. Image data was post-processed with a software prototype. After material decomposition, an iron enhancement map was created and freehand ROIs were drawn including most of the partially examined liver. The virtual iron content (VIC) was calculated and expressed in milligram/millilitre. VIC was correlated with serum ferritin and estimated amount of transfused iron. Scans of patients who had not received blood products were considered controls. RESULTS: Forty-eight (32.7%) cases (controls) had not received any blood transfusions whereas 67.3% had received one transfusion or more. Median serum ferritin and VIC were 138.0 µg/dl (range, 6.0-2628.0 µg/dl) and 1.33 mg/ml (range, - 0.94-7.56 mg/ml) in the post-transfusional group and 27.0 µg/dl (range, 1.0-248.0 µg/dl) and 0.61 mg/ml (range, - 2.1-2.4) in the control group. Correlation between serum ferritin and VIC was strong (r = 0.623; p < 0.001) as well as that between serum ferritin and estimated quantity of transfused iron (r = 0.681; p < 0.001). CONCLUSIONS: Hepatic VIC obtained via dual-energy chest-CT examinational protocol strongly correlates with serum ferritin levels and estimated amount of transfused iron and could therefore be used in the routine diagnosis for complementary evaluation of transfusional haemosiderosis. KEY POINTS: • Virtual liver iron content was measured in routine chest-CTs of haematological patients suspected of having iron overload. Chest-CTs were primarily intended for exclusion of pulmonary infection. • Measurements correlate strongly with the most widely used blood marker of iron overload serum ferritin (after exclusion of infection) and the amount of transfused iron. • Liver VIC could be used for supplemental evaluation of transfusional haemosiderosis in haematological patients.


Assuntos
Sobrecarga de Ferro/diagnóstico , Ferro/metabolismo , Fígado/metabolismo , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/metabolismo , Feminino , Humanos , Sobrecarga de Ferro/metabolismo , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
10.
J Neuroradiol ; 45(5): 290-294, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29412162

RESUMO

PURPOSE: To assess the diagnostic utility of different perfusion algorithms for the detection of angiographical terial spasm. METHOD: During a 2-year period, 45 datasets from 29 patients (54.2±10,75y, 20F) with suspected cerebral vasospasm after aneurysmal subarachnoid hemorrhage were included. Volume Perfusion CT (VPCT), Non-enhanced CT (NCT) and angiography were performed within 6hours post-ictus. Perfusion maps were generated using a maximum slope (MS) and a deconvolution-based approach (DC). Two blinded neuroradiologists independently evaluated MS and DC maps regarding vasospasm-related perfusion impairment on a 3-point Likert-scale (0=no impairment, 1=impairment affecting <50%, 2=impairment affecting >50% of vascular territory). A third independent neuroradiologist assessed angiography for presence and severity of arterial narrowing on a 3-point Likert scale (0=no narrowing, 1=narrowing affecting <50%, 2=narrowing affecting>50% of artery diameter). MS and DC perfusion maps were evaluated regarding diagnostic accuracy for angiographical arterial spasm with angiography as reference standard. Correlation analysis of angiography findings with both MS and DC perfusion maps was additionally performed. Furthermor, the agreement between MS and DC and inter-reader agreement was assessed. RESULTS: DC maps yielded significantly higher diagnostic accuracy than MS perfusion maps (DC:AUC=.870; MS:AUC=.805; P=0.007) with higher sensitivity for DC compared to MS (DC:sensitivity=.758; MS:sensitivity=.625). DC maps revealed stronger correlation with angiography than MS (DC: R=.788; MS: R=694;=<0.001). MS and DC showed substantial agreement (Kappa=.626). Regarding inter-reader analysis, (almost) perfect inter-reader agreement was observed for both MS and DC maps (Kappa≥981). CONCLUSION: DC yields significantly higher diagnostic accuracy for the detection of angiographic arterial spasm and higher correlation with angiographic findings compared to MS.


Assuntos
Angiografia Cerebral/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Hemorragia Subaracnóidea/complicações , Hemorragia Subaracnóidea/terapia , Tomografia Computadorizada por Raios X/métodos , Vasoespasmo Intracraniano/diagnóstico por imagem , Vasoespasmo Intracraniano/etiologia , Adulto , Idoso , Algoritmos , Angiografia Digital , Meios de Contraste , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade , Hemorragia Subaracnóidea/diagnóstico por imagem
11.
PLoS One ; 12(3): e0173592, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28319203

RESUMO

OBJECTIVE: Very short acquisition times and the use of low-kV protocols in CTA demand modifications in the contrast media (CM) injection regimen. The aim of this study was to optimize the use of CM delivery parameters in thoraco-abdominal CTA in a porcine model. MATERIALS AND METHODS: Six pigs (55-68 kg) were examined with a dynamic CTA protocol (454 mm scan length, 2.5 s temporal resolution, 70 s total acquisition time). Four CM injection protocols were applied in a randomized order. 120 kV CTA protocol: (A) 300 mg iodine/kg bodyweight (bw), IDR = 1.5 g/s (flow = 5 mL/s), injection time (ti) 12 s (60 kg bw). 70 kV CTA protocols: 150 mg iodine/kg bw: (B) IDR = 0.75 g/s (flow = 2.5 mL/s), ti = 12 s (60 kg bw); (C) IDR = 1.5 g/s (flow = 5 mL/s), ti = 12 s (60 kg bw); (D) IDR = 3.0 g/s (flow = 10 mL/s), ti = 3 s (60 kg bw). The complete CM bolus shape was monitored by creating time attenuation curves (TAC) in different vascular territories. Based on the TAC, the time to peak (TTP) and the peak enhancement were determined. The diagnostic window (relative enhancement > 300 HU), was calculated and compared to visual inspection of the corresponding CTA data sets. RESULTS: The average relative arterial peak enhancements after baseline correction were 358.6 HU (A), 356.6 HU (B), 464.0 HU (C), and 477.6 HU (D). The TTP decreased with increasing IDR and decreasing ti, protocols A and B did not differ significantly (systemic arteries, p = 0.843; pulmonary arteries, p = 0.183). The delay time for bolus tracking (trigger level 100 HU; target enhancement 300 HU) for single-phase CTA was comparable for protocol A and B (3.9, 4.3 s) and C and D (2.4, 2.0 s). The scan window time frame was comparable for the different protocols by visual inspection of the different CTA data sets and by analyzing the TAC. CONCLUSIONS: All protocols provided sufficient arterial enhancement. The use of a 70 kV CTA protocol is recommended because of a 50% reduction of total CM volume and a 50% reduced flow rate while maintaining the bolus profile. In contrast to pulmonary arterial enhancement, the systemic arterial enhancement improved only slightly increasing the IDR from 1.5 g/s to 3 g/s because of bolus dispersion of the very short bolus (3s) in the lungs.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste/administração & dosagem , Iodo/administração & dosagem , Animais , Feminino , Modelos Animais , Sus scrofa , Fatores de Tempo
12.
Eur Radiol ; 26(9): 2929-36, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26679179

RESUMO

OBJECTIVES: To assess the value of iodine concentration (IC) in computed tomography data acquired with 80 kVp, as a surrogate for perfusion imaging in hepatocellular carcinoma (HCC) and lymphoma by comparing iodine related attenuation (IRA) with quantitative Volume Perfusion CT (VPCT)-parameters. METHODS: VPCT-parameters were compared with intra-tumoral IC at 5 time points after the aortic peak enhancement (APE) with a temporal resolution of 3.5 sec in untreated 30 HCC and 30 lymphoma patients. RESULTS: Intra-tumoral perfusion parameters for HCC showed a blood flow (BF) of 52.7 ± 17.0 mL/100 mL/min, blood volume (BV) 12.6 ± 4.3 mL/100 mL, arterial liver perfusion (ALP) 44.4 ± 12.8 mL/100 mL/min. Lesion IC 7 sec after APE was 133.4 ± 57.3 mg/100 mL. Lymphoma showed a BF of 36.8 ± 13.4 mL/100 mL/min, BV of 8.8 ± 2.8 mL/100 mL and IC of 118.2 ± 64.5 mg/100 mL 3.5 sec after APE. Strongest correlations exist for VPCT-derived BF and ALP with IC in HCC 7 sec after APE (r = 0.71 and r = 0.84) and 3.5 sec after APE in lymphoma lesions (r = 0.77). Significant correlations are also present for BV (r = 0.60 and r = 0.65 for HCC and lymphoma, respectively). CONCLUSIONS: We identified a good, time-dependent agreement between VPCT-derived flow values and IC in HCC and lymphoma. Thus, CT-derived ICs 7 sec after APE in HCC and 3.5 sec in lymphoma may be used as surrogate imaging biomarkers for tumor perfusion with 80 kVp. KEY POINTS: • Iodine concentration derived from low kVp CT is regarded as perfusion surrogate • Correlation with Perfusion CT was performed to elucidate timing and histology dependencies • Highest correlation was present 7 sec after aortic peak enhancement in hepatocellular carcinoma • In lymphoma, highest correlation was calculated 3.5 sec after aortic peak enhancement • With these results, further optimization of Dual energy CT protocols is possible.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico/métodos , Iodo/farmacocinética , Neoplasias Hepáticas/diagnóstico por imagem , Linfoma/diagnóstico por imagem , Imagem de Perfusão/métodos , Idoso , Idoso de 80 Anos ou mais , Biomarcadores , Volume Sanguíneo , Feminino , Humanos , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
13.
AJR Am J Roentgenol ; 205(6): 1332-8, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26587942

RESUMO

OBJECTIVE: The purpose of this study was to systematically investigate radiation dose reduction using automated tube voltage selection during CT angiography (CTA) and to evaluate the impact of contrast medium (CM) injection protocols on dose reduction. MATERIALS AND METHODS: A circulation phantom containing the thoracic and abdominal vasculature was used. Four different concentrations of CM (iopromide 300 and 370 mg I/mL and iomeprol 350 and 400 mg I/mL) were administered while maintaining an identical iodine delivery rate (1.8 g I/s) and total iodine load (20.0 g). Three different scanning protocols for CTA of the thoracoabdominal aorta were used: protocol A, no dose modulation; protocol B, automated tube current modulation (CARE Dose4D); and protocol C, automated tube voltage selection (CARE kV). The dose-length product was recorded to calculate the effective dose. Attenuation values (in Hounsfield units), image noise levels, and signal-to-noise ratios (SNRs) in six predefined intravascular sites (three thoracic and three abdominal) were measured by two readers. All values were analyzed using the Kruskal-Wallis test and two-way ANOVA. RESULTS: There was a significant reduction in the effective dose (in millisieverts) for protocols B (mean ± SD, 2.03 ± 0.1 mSv) and C (1.00 ± 0.0 mSv) compared with protocol A (4.34 ± 0.0 mSv). The dose was reduced by 53% for protocol B and by 77% for protocol C. No significant differences were found in the effective dose among the different CM injection protocols within the scanning protocols; all p values were > 0.05. The attenuation values and SNRs were comparable among all the different CM injection protocols; all p values were > 0.05. CONCLUSION: A large radiation dose reduction (77%) can be achieved using automated tube voltage selection independent of the CM injection protocol.


Assuntos
Aortografia/métodos , Meios de Contraste/administração & dosagem , Iohexol/análogos & derivados , Iopamidol/análogos & derivados , Proteção Radiológica/métodos , Tomografia Computadorizada por Raios X/métodos , Aortografia/instrumentação , Humanos , Iohexol/administração & dosagem , Iopamidol/administração & dosagem , Imagens de Fantasmas , Doses de Radiação , Tomografia Computadorizada por Raios X/instrumentação
14.
Biomed Res Int ; 2015: 412716, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26185756

RESUMO

OBJECTIVE: To test the feasibility of a CT-compatible, ex vivo, perfused porcine heart model for myocardial perfusion CT imaging. METHODS: One porcine heart was perfused according to Langendorff. Dynamic perfusion scanning was performed with a second-generation dual source CT scanner. Circulatory parameters like blood flow, aortic pressure, and heart rate were monitored throughout the experiment. Stenosis was induced in the circumflex artery, controlled by a fractional flow reserve (FFR) pressure wire. CT-derived myocardial perfusion parameters were analysed at FFR of 1 to 0.10/0.0. RESULTS: CT images did not show major artefacts due to interference of the model setup. The pacemaker-induced heart rhythm was generally stable at 70 beats per minute. During most of the experiment, blood flow was 0.9-1.0 L/min, and arterial pressure varied between 80 and 95 mm/Hg. Blood flow decreased and arterial pressure increased by approximately 10% after inducing a stenosis with FFR ≤ 0.50. Dynamic perfusion scanning was possible across the range of stenosis grades. Perfusion parameters of circumflex-perfused myocardial segments were affected at increasing stenosis grades. CONCLUSION: An adapted Langendorff porcine heart model is feasible in a CT environment. This model provides control over physiological parameters and may allow in-depth validation of quantitative CT perfusion techniques.


Assuntos
Estenose Coronária/diagnóstico por imagem , Modelos Animais de Doenças , Preparação de Coração Isolado/métodos , Imagem de Perfusão do Miocárdio/métodos , Técnicas de Cultura de Órgãos/métodos , Tomografia Computadorizada por Raios X/métodos , Animais , Angiografia Coronária/métodos , Humanos , Perfusão/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Suínos
15.
Eur J Radiol ; 84(12): 2359-67, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26137905

RESUMO

The aim of this review article is to define the technical prerequisites of modern state-of-the-art CT perfusion imaging in oncology at reasonable dose levels. The focus is mainly on abdominal and thoracic tumor imaging, as they pose the largest challenges with respect to attenuation and patient motion. We will show that low kV dynamic scanning in conjunction with detection technology optimized for low photon fluxes has the highest impact on reducing dose independently of other choices made in the protocol selection. We discuss, derived from relatively simple first principles, on what appropriate temporal sampling and total scan duration depend on and why optimized contrast medium injection protocols are also essential in limiting dose. Finally we will examine the possibility of simultaneously extracting standard morphological and functional information from one single 4D examination as a potential enabler for a more widespread use of dynamic contrast enhanced CT in oncology.


Assuntos
Meios de Contraste , Intensificação de Imagem Radiográfica , Tomografia Computadorizada por Raios X , Humanos , Radiografia Abdominal , Radiografia Torácica
16.
Eur J Radiol ; 82(12): e894-900, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24094644

RESUMO

OBJECTIVE: To evaluate dynamic volume perfusion CT (dVPCT) tumor baseline characteristics of three different subtypes of lung cancer in untreated patients. MATERIALS AND METHODS: 173 consecutive patients (131 men, 42 women; mean age 61 ± 10 years) with newly diagnosed lung cancer underwent dVPCT prior to biopsy. Tumor permeability, blood flow (BF), blood volume (BV) and mean transit time (MTT) were quantitatively assessed as well as tumor diameter and volume. Tumor subtypes were histologically determined and compared concerning their dVPCT results. dVPCT results were correlated to tumor diameter and volume. RESULTS: Histology revealed adenocarcinoma in 88, squamous cell carcinoma in 54 and small cell lung cancer (SCLC) in 31 patients. Tumor permeability was significantly differing between adenocarcinoma, squamous cell carcinoma and SCLC (all p<0.05). Tumor BF and BV were higher in adenocarcinomathan in SCLC (p = 0.001 and p=0.0002 respectively). BV was also higher in squamous cell carcinoma compared to SCLC (p = 0.01). MTT was not differing between tumor subtypes. Regarding all tumors, tumor diameter did not correlate with any of the dVPCT parameters, whereas tumor volume was negatively associated with permeability, BF and BV (r = -0.22, -0.24, -0.24, all p<0.05). In squamous cell carcinoma, tumor diameter und volume correlated with BV (r = 0.53 and r = -0.40, all p<0.05). In SCLC, tumor diameter und volume correlated with MTT (r = 0.46 and r = 0.39, all p<0.05). In adenocarcinoma, no association between morphological and functional tumor characteristics was observed. CONCLUSIONS: dVPCT parameters are only partially related to tumor diameter and volume and are significantly differing between lung cancer subtypes.


Assuntos
Imageamento Tridimensional/métodos , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/fisiopatologia , Imagem de Perfusão/estatística & dados numéricos , Circulação Pulmonar , Idoso , Idoso de 80 Anos ou mais , China , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Fatores de Risco , Sensibilidade e Especificidade , Carga Tumoral
17.
Eur J Radiol ; 81(12): 4105-11, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22959826

RESUMO

BACKGROUND: To evaluate the preoperative diagnostic power and classification accuracy of perfusion parameters derived from whole brain volume perfusion CT (VPCT) in patients with cerebral tumors. METHODS: Sixty-three patients (31 male, 32 female; mean age 55.6 ± 13.9 years), with MRI findings suspected of cerebral lesions, underwent VPCT. Two readers independently evaluated VPCT data. Volumes of interest (VOIs) were marked circumscript around the tumor according to maximum intensity projection volumes, and then mapped automatically onto the cerebral blood volume (CBV), flow (CBF) and permeability Ktrans perfusion datasets. A second VOI was placed in the contra lateral cortex, as control. Correlations among perfusion values, tumor grade, cerebral hemisphere and VOIs were evaluated. Moreover, the diagnostic power of VPCT parameters, by means of positive and negative predictive value, was analyzed. RESULTS: Our cohort included 32 high-grade gliomas WHO III/IV, 18 low-grade I/II, 6 primary cerebral lymphomas, 4 metastases and 3 tumor-like lesions. Ktrans demonstrated the highest sensitivity, specificity and positive predictive value, with a cut-off point of 2.21 mL/100mL/min, for both the comparisons between high-grade versus low-grade and low-grade versus primary cerebral lymphomas. However, for the differentiation between high-grade and primary cerebral lymphomas, CBF and CBV proved to have 100% specificity and 100% positive predictive value, identifying preoperatively all the histopathologically proven high-grade gliomas. CONCLUSION: Volumetric perfusion data enable the hemodynamic assessment of the entire tumor extent and provide a method of preoperative differentiation among intra-axial cerebral tumors with promising diagnostic accuracy.


Assuntos
Algoritmos , Neoplasias Encefálicas/patologia , Imageamento Tridimensional/métodos , Neovascularização Patológica/patologia , Imagem de Perfusão/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Neoplasias Encefálicas/complicações , Neoplasias Encefálicas/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neovascularização Patológica/diagnóstico por imagem , Neovascularização Patológica/etiologia , Cuidados Pré-Operatórios , Prognóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Carga Tumoral
18.
Eur Radiol ; 21(9): 1811-9, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21573969

RESUMO

OBJECTIVES: Validation of the feasibility and efficacy of volume perfusion computed tomography (VPCT) in the preoperative assessment of cerebral gliomas by applying a 128-slice CT covering the entire tumour. METHODS: Forty-six patients (25 men, 21 women; mean age 52.8 years) with cerebral gliomas were evaluated with VPCT. Two readers independently evaluated VPCT data, drawing volumes of interest (VOIs) around the tumour according to maximum intensity projection volumes, which were mapped automatically onto the cerebral blood volume (CBV), flow (CBF) and permeability (Ktrans) perfusion datasets. As control, a second VOI was placed in the contralateral healthy cortex. Correlation among perfusion parameters, tumour grade, hemisphere and VOIs was assessed. The diagnostic power of perfusion parameters was analysed by receiver operating characteristics curve analyses. RESULTS: VPCT was feasible in the assessment of the entire tumour extent. Mean values of Ktrans, CBV, CBF in high-grade gliomas were significantly higher compared with low-grade (p < 0.01). Ktrans demonstrated the highest diagnostic (97% sensitivity), positive (100%) and negative (94%) prognostic values. CONCLUSIONS: VPCT was feasible in all subjects. All areas of different perfusion characteristics are depicted and quantified in colour-coded 3D maps. The derived parameters correlate well with tumour histopathology, differentiating low- from high-grade gliomas.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico/métodos , Glioma/diagnóstico por imagem , Intensificação de Imagem Radiográfica , Adulto , Idoso , Análise de Variância , Biópsia por Agulha , Neoplasias Encefálicas/patologia , Neoplasias Encefálicas/cirurgia , Circulação Cerebrovascular/fisiologia , Estudos de Coortes , Meios de Contraste , Estudos de Viabilidade , Feminino , Glioma/patologia , Glioma/cirurgia , Humanos , Imuno-Histoquímica , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Perfusão/métodos , Cuidados Pré-Operatórios/métodos , Curva ROC , Sensibilidade e Especificidade
20.
Acta Radiol ; 51(7): 793-9, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20583948

RESUMO

BACKGROUND: Recently published data show some controversy concerning the impact of [18F]-fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) in predicting head and neck tumors (HNT) outcome. Assessment of tumor blood supply parameters using dynamic contrast-enhanced CT (DCE-CT) may deliver additional information concerning this important question. PURPOSE: To evaluate the contribution of DCE-CT implemented in pretherapeutic FDG-PET/CT protocol for prognosis prediction in patients with HNT. MATERIAL AND METHODS: Ten consecutive patients (median age 50 years, range 47-74 years) with histologically proven HNT underwent FDG-PET/CT with DCE-CT before treatment. FDG uptake was measured by maximum standardized uptake value (SUV(max)). Relative tumor blood volume (rTBV) was determined from DCE-CT using Patlak analysis. Intratumoral heterogeneity was assessed by means of lacunarity analysis. Obtained values were compared with time-to-progression and overall survival. PET and DCE-CT images were compared on a pixel-by-pixel basis using Pearson coefficient of correlation. RESULTS: Three patients with lower FDG uptake (SUV(max): 8+/-1) and five patients with higher FDG uptake (SUV(max): 15+/-4, P=0.004) were free of local recurrence for 24 months. Two groups of patients with significantly differing lower (group A: 0.37+/-0.02, n=6) and higher (group B: 0.52+/-0.01, n=4; P<0.01), tumor heterogeneity (lacunarity) were identified. Corresponding mean rTBV was higher in group A (9.6+/-1.8 ml/100 ml) than in group B (6.2+/-0.6 ml/100 ml). All six patients with homogeneous tumor blood supply (lower lacunarity) and higher rTBV were free of local recurrence during 24 months, while two of four patients with heterogeneous tumor blood supply (higher lacunarity) and lower rTBV died during follow-up due to tumor relapse. A weak correlation between FDG-PET and DCE-CT rTBV was observed (R(2)=0.1). CONCLUSION: FDG-PET/CT and DCT-CT are complementary methods for surveillance assessment in patients with HNT. Implementation of DCE-CT in the pretreatment FDG-PET/CT protocol may improve tumor outcome prediction.


Assuntos
Carcinoma de Células Escamosas/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Carcinoma de Células Escamosas/irrigação sanguínea , Carcinoma de Células Escamosas/patologia , Meios de Contraste , Progressão da Doença , Feminino , Fluordesoxiglucose F18/farmacocinética , Neoplasias de Cabeça e Pescoço/irrigação sanguínea , Neoplasias de Cabeça e Pescoço/patologia , Humanos , Interpretação de Imagem Assistida por Computador , Injeções Intravenosas , Iohexol/análogos & derivados , Iohexol/farmacocinética , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Valor Preditivo dos Testes , Compostos Radiofarmacêuticos/farmacocinética , Estatísticas não Paramétricas , Taxa de Sobrevida
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...