Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 168
Filtrar
1.
Phys Rev Lett ; 124(22): 225002, 2020 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-32567902

RESUMO

The free-free opacity in plasmas is fundamental to our understanding of energy transport in stellar interiors and for inertial confinement fusion research. However, theoretical predictions in the challenging dense plasma regime are conflicting and there is a dearth of accurate experimental data to allow for direct model validation. Here we present time-resolved transmission measurements in solid-density Al heated by an XUV free-electron laser. We use a novel functional optimization approach to extract the temperature-dependent absorption coefficient directly from an oversampled pool of single-shot measurements, and find a pronounced enhancement of the opacity as the plasma is heated to temperatures of order of the Fermi energy. Plasma heating and opacity enhancement are observed on ultrafast timescales, within the duration of the femtosecond XUV pulse. We attribute further rises in the opacity on ps timescales to melt and the formation of warm dense matter.

2.
Struct Dyn ; 2(4): 041701, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26798801

RESUMO

Intense femtosecond x-ray pulses from free-electron laser sources allow the imaging of individual particles in a single shot. Early experiments at the Linac Coherent Light Source (LCLS) have led to rapid progress in the field and, so far, coherent diffractive images have been recorded from biological specimens, aerosols, and quantum systems with a few-tens-of-nanometers resolution. In March 2014, LCLS held a workshop to discuss the scientific and technical challenges for reaching the ultimate goal of atomic resolution with single-shot coherent diffractive imaging. This paper summarizes the workshop findings and presents the roadmap toward reaching atomic resolution, 3D imaging at free-electron laser sources.

3.
Opt Express ; 21(9): 11441-7, 2013 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-23670000

RESUMO

We present single shot nanoscale imaging using a table-top femtosecond soft X-ray laser harmonic source at a wavelength of 32 nm. We show that the phase retrieval process in coherent diffractive imaging critically depends on beam quality. Coherence and image fidelity are measured from single-shot coherent diffraction patterns of isolated nano-patterned slits. Impact of flux, wave front and coherence of the soft X-ray beam on the phase retrieval process and the image quality are discussed. After beam improvements, a final image reconstruction is presented with a spatial resolution of 78 nm (half period) in a single 20 fs laser harmonic shot.


Assuntos
Algoritmos , Artefatos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Nanopartículas/ultraestrutura , Difração de Raios X/métodos
4.
Phys Rev Lett ; 108(13): 133401, 2012 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-22540697

RESUMO

Explosions of large Xe clusters ( ~ 11,000) irradiated by femtosecond pulses of 850 eV x-ray photons focused to an intensity of up to 10(17) W/cm(2) from the Linac Coherent Light Source were investigated experimentally. Measurements of ion charge-state distributions and energy spectra exhibit strong evidence for the formation of a Xe nanoplasma in the intense x-ray pulse. This x-ray produced Xe nanoplasma is accompanied by a three-body recombination and hydrodynamic expansion. These experimental results appear to be consistent with a model in which a spherically exploding nanoplasma is formed inside the Xe cluster and where the plasma temperature is determined by photoionization heating.

5.
Phys Rev E Stat Nonlin Soft Matter Phys ; 83(1 Pt 2): 016403, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21405780

RESUMO

Studies of materials under extreme conditions have relevance to a broad area of research, including planetary physics, fusion research, materials science, and structural biology with x-ray lasers. We study such extreme conditions and experimentally probe the interaction between ultrashort soft x-ray pulses and solid targets (metals and their deuterides) at the FLASH free-electron laser where power densities exceeding 10(17) W/cm(2) were reached. Time-of-flight ion spectrometry and crater analysis were used to characterize the interaction. The results show the onset of saturation in the ablation process at power densities above 10(16) W/cm(2). This effect can be linked to a transiently induced x-ray transparency in the solid by the femtosecond x-ray pulse at high power densities. The measured kinetic energies of protons and deuterons ejected from the surface reach several keV and concur with predictions from plasma-expansion models. Simulations of the interactions were performed with a nonlocal thermodynamic equilibrium code with radiation transfer. These calculations return critical depths similar to the observed crater depths and capture the transient surface transparency at higher power densities.

6.
Phys Rev Lett ; 104(22): 225001, 2010 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-20867176

RESUMO

By use of high intensity XUV radiation from the FLASH free-electron laser at DESY, we have created highly excited exotic states of matter in solid-density aluminum samples. The XUV intensity is sufficiently high to excite an inner-shell electron from a large fraction of the atoms in the focal region. We show that soft-x-ray emission spectroscopy measurements reveal the electronic temperature and density of this highly excited system immediately after the excitation pulse, with detailed calculations of the electronic structure, based on finite-temperature density functional theory, in good agreement with the experimental results.


Assuntos
Alumínio/química , Elétrons , Processos Fotoquímicos , Gases em Plasma/química , Raios Ultravioleta
7.
Phys Rev Lett ; 104(22): 225501, 2010 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-20867179

RESUMO

We reconstructed the 3D Fourier intensity distribution of monodisperse prolate nanoparticles using single-shot 2D coherent diffraction patterns collected at DESY's FLASH facility when a bright, coherent, ultrafast x-ray pulse intercepted individual particles of random, unmeasured orientations. This first experimental demonstration of cryptotomography extended the expansion-maximization-compression framework to accommodate unmeasured fluctuations in photon fluence and loss of data due to saturation or background scatter. This work is an important step towards realizing single-shot diffraction imaging of single biomolecules.


Assuntos
Análise de Fourier , Imageamento Tridimensional/métodos , Espalhamento de Radiação , Tomografia/métodos , Estudos de Viabilidade , Compostos Férricos/química , Nanopartículas/química
8.
Phys Rev Lett ; 105(8): 083004, 2010 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-20868096

RESUMO

The Linac Coherent Light Source free electron laser is a source of high brightness x rays, 2×10(11) photons in a ∼5 fs pulse, that can be focused to produce double core vacancies through rapid sequential ionization. This enables double core vacancy Auger electron spectroscopy, an entirely new way to study femtosecond chemical dynamics with Auger electrons that probe the local valence structure of molecules near a specific atomic core. Using 1.1 keV photons for sequential x-ray ionization of impulsively aligned molecular nitrogen, we observed a rich single-site double core vacancy Auger electron spectrum near 413 eV, in good agreement with ab initio calculations, and we measured the corresponding Auger electron angle dependence in the molecular frame.


Assuntos
Elétrons , Fenômenos Físicos , Luz , Nitrogênio/química , Teoria Quântica , Análise Espectral , Fatores de Tempo
9.
Opt Express ; 18(17): 17620-30, 2010 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-20721148

RESUMO

The first time-resolved x-ray/optical pump-probe experiments at the SLAC Linac Coherent Light Source (LCLS) used a combination of feedback methods and post-analysis binning techniques to synchronize an ultrafast optical laser to the linac-based x-ray laser. Transient molecular nitrogen alignment revival features were resolved in time-dependent x-ray-induced fragmentation spectra. These alignment features were used to find the temporal overlap of the pump and probe pulses. The strong-field dissociation of x-ray generated quasi-bound molecular dications was used to establish the residual timing jitter. This analysis shows that the relative arrival time of the Ti:Sapphire laser and the x-ray pulses had a distribution with a standard deviation of approximately 120 fs. The largest contribution to the jitter noise spectrum was the locking of the laser oscillator to the reference RF of the accelerator, which suggests that simple technical improvements could reduce the jitter to better than 50 fs.


Assuntos
Elétrons , Lasers , Síncrotrons , Desenho de Equipamento , Fibras Ópticas , Fatores de Tempo , Raios X
10.
Opt Express ; 17(20): 18271-8, 2009 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-19907618

RESUMO

We have focused a beam (BL3) of FLASH (Free-electron LASer in Hamburg: lambda = 13.5 nm, pulse length 15 fs, pulse energy 10-40 microJ, 5 Hz) using a fine polished off-axis parabola having a focal length of 270 mm and coated with a Mo/Si multilayer with an initial reflectivity of 67% at 13.5 nm. The OAP was mounted and aligned with a picomotor controlled six-axis gimbal. Beam imprints on poly(methyl methacrylate) - PMMA were used to measure focus and the focused beam was used to create isochoric heating of various slab targets. Results show the focal spot has a diameter of < or =1 microm. Observations were correlated with simulations of best focus to provide further relevant information.


Assuntos
Lasers , Lentes , Teste de Materiais/instrumentação , Teste de Materiais/métodos , Difração de Raios X/instrumentação , Difração de Raios X/métodos , Desenho Assistido por Computador , Elétrons , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
11.
Phys Rev Lett ; 103(2): 028104, 2009 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-19659250

RESUMO

Coherent x-ray diffractive imaging is a powerful method for studies on nonperiodic structures on the nanoscale. Access to femtosecond dynamics in major physical, chemical, and biological processes requires single-shot diffraction data. Up to now, this has been limited to intense coherent pulses from a free electron laser. Here we show that laser-driven ultrashort x-ray sources offer a comparatively inexpensive alternative. We present measurements of single-shot diffraction patterns from isolated nano-objects with a single 20 fs pulse from a table-top high-harmonic x-ray laser. Images were reconstructed with a resolution of 119 nm from the single shot and 62 nm from multiple shots.


Assuntos
Difração de Raios X/métodos , Processamento de Imagem Assistida por Computador/métodos , Lasers
12.
Opt Express ; 17(1): 208-17, 2009 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-19129890

RESUMO

We report the first observation of single-shot soft x-ray laser induced desorption occurring below the ablation threshold in a thin layer of poly (methyl methacrylate)--PMMA. Irradiated by the focused beam from the Free-electron LASer in Hamburg (FLASH) at 21.7 nm, the samples have been investigated by atomic-force microscope (AFM) enabling the visualization of mild surface modifications caused by the desorption. A model describing non-thermal desorption and ablation has been developed and used to analyze single-shot imprints in PMMA. An intermediate regime of materials removal has been found, confirming model predictions. We also report below-threshold multiple-shot desorption of PMMA induced by high-order harmonics (HOH) at 32 nm. Short-time exposure imprints provide sufficient information about transverse beam profile in HOH's tight focus whereas long-time exposed PMMA exhibits radiation-initiated surface ardening making the beam profile measurement infeasible.


Assuntos
Lasers , Raios X , Compostos de Boro/efeitos da radiação , Carbono/efeitos da radiação , Elétrons , Terapia a Laser/métodos , Microscopia de Força Atômica , Polimetil Metacrilato , Espectrofotometria , Propriedades de Superfície , Raios Ultravioleta
13.
Phys Rev Lett ; 100(13): 135502, 2008 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-18517965

RESUMO

Femtosecond time-resolved small and wide angle x-ray diffuse scattering techniques are applied to investigate the ultrafast nucleation processes that occur during the ablation process in semiconducting materials. Following intense optical excitation, a transient liquid state of high compressibility characterized by large-amplitude density fluctuations is observed and the buildup of these fluctuations is measured in real time. Small-angle scattering measurements reveal snapshots of the spontaneous nucleation of nanoscale voids within a metastable liquid and support theoretical predictions of the ablation process.

14.
Fetal Diagn Ther ; 23(2): 136-9, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18046072

RESUMO

An abnormal course of the umbilical vein is a rare anomaly. Its association with the congenital absence of the ductus venosus is common. We found 3 cases of an abnormal course of the umbilical vein and an absent ductus venosus. In 2 of these cases, the umbilical vein turned down and continued in the internal iliac vein, and no ductus venosus was found. One of these pregnancies was terminated. From the continued pregnancy a growth-retarded baby was born. At follow-up examinations, mild microcephaly, mildly elevated levels of ammonia, delayed speech and mild muscular hypotonia were found. In the third case, the umbilical vein turned up from the level of umbilical ring and the anterior of the liver above the diaphragma and connected directly into the right atrium. Associated complex congenital heart malformations - transposition of the great arteries, and ventricular septal defect - were diagnosed prenatally. In the umbilical vein from the placenta to the umbilical ring, the flow was low velocity continuous; from the umbilical ring to the right atrium, the flow was biphasic high velocity (90 cm/s). Such an elevated blood flow could be a sign of increased cardiac preload. The long-term neurological follow-up of babies with prenatally diagnosed venous malformations is necessary.


Assuntos
Coração Fetal/anormalidades , Coração Fetal/diagnóstico por imagem , Diagnóstico Pré-Natal/métodos , Veias Umbilicais/anormalidades , Veias Umbilicais/diagnóstico por imagem , Anormalidades Múltiplas/diagnóstico , Anormalidades Múltiplas/diagnóstico por imagem , Adulto , Feminino , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/diagnóstico por imagem , Humanos , Recém-Nascido , Masculino , Gravidez , Ultrassonografia
15.
Phys Rev Lett ; 98(12): 125501, 2007 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-17501133

RESUMO

The ultrafast decay of the x-ray diffraction intensity following laser excitation of an InSb crystal has been utilized to observe carrier dependent changes in the potential energy surface. For the first time, an abrupt carrier dependent onset for potential energy surface softening and the appearance of accelerated atomic disordering for a very high average carrier density have been observed. Inertial dynamics dominate the early stages of crystal disordering for a wide range of carrier densities between the onset of crystal softening and the appearance of accelerated atomic disordering.

16.
Science ; 315(5812): 633-6, 2007 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-17272718

RESUMO

Intense femtosecond laser excitation can produce transient states of matter that would otherwise be inaccessible to laboratory investigation. At high excitation densities, the interatomic forces that bind solids and determine many of their properties can be substantially altered. Here, we present the detailed mapping of the carrier density-dependent interatomic potential of bismuth approaching a solid-solid phase transition. Our experiments combine stroboscopic techniques that use a high-brightness linear electron accelerator-based x-ray source with pulse-by-pulse timing reconstruction for femtosecond resolution, allowing quantitative characterization of the interatomic potential energy surface of the highly excited solid.

17.
Opt Express ; 15(10): 6036-43, 2007 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-19546907

RESUMO

A linear accelerator based source of coherent radiation, FLASH (Free-electron LASer in Hamburg) provides ultra-intense femtosecond radiation pulses at wavelengths from the extreme ultraviolet (XUV; lambda<100nm) to the soft X-ray (SXR; lambda<30nm) spectral regions. 25-fs pulses of 32-nm FLASH radiation were used to determine the ablation parameters of PMMA - poly (methyl methacrylate). Under these irradiation conditions the attenuation length and ablation threshold were found to be (56.9+/-7.5) nm and approximately 2 mJ*cm(-2), respectively. For a second wavelength of 21.7 nm, the PMMA ablation was utilized to image the transverse intensity distribution within the focused beam at mum resolution by a method developed here.

18.
Fetal Diagn Ther ; 21(2): 198-203, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16491003

RESUMO

OBJECTIVE: To find connection between the type of congenital heart malformations and twin pregnancies. METHOD: Retrospective analysis of data of fetal cardiology database between 1 January 1996 and 30 November 2003. RESULTS: In single pregnancies 455 and in twin pregnancies 31 severe congenital heart malformations were diagnosed prenatally. In monozygotic twin pregnancies 36% of heart malformations were pulmonary stenosis and 45% endocardial fibroelastosis, which is significantly higher than in single pregnancies. In dizygotic twin pregnancies Ebstein malformation was significantly more frequent than in single pregnancies. With the exception of Ebstein malformation in dichorionic and dizygotic twin pregnancies the cardiac malformations were similar to the ones in single pregnancies. CONCLUSIONS: The twin pregnancy alone can be considered as indication for fetal echocardiography. The type of congenital heart malformations detected in monochorial twin pregnancies was different from those found in single, dizygotic or dichorionic twin pregnancies. Chorionicity seems to be more important than zygosity.


Assuntos
Cardiopatias Congênitas/epidemiologia , Gêmeos Dizigóticos , Gêmeos Monozigóticos , Feminino , Humanos , Hungria/epidemiologia , Incidência , Placentação , Gravidez , Diagnóstico Pré-Natal , Estudos Retrospectivos
19.
Phys Rev Lett ; 95(12): 125701, 2005 Sep 16.
Artigo em Inglês | MEDLINE | ID: mdl-16197085

RESUMO

The melting dynamics of laser excited InSb have been studied with femtosecond x-ray diffraction. These measurements observe the delayed onset of diffusive atomic motion, signaling the appearance of liquidlike dynamics. They also demonstrate that the root-mean-squared displacement in the [111] direction increases faster than in the [110] direction after the first 500 fs. This structural anisotropy indicates that the initially generated fluid differs significantly from the equilibrium liquid.

20.
Phys Rev Lett ; 94(11): 114801, 2005 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-15903864

RESUMO

Linear-accelerator-based sources will revolutionize ultrafast x-ray science due to their unprecedented brightness and short pulse duration. However, time-resolved studies at the resolution of the x-ray pulse duration are hampered by the inability to precisely synchronize an external laser to the accelerator. At the Sub-Picosecond Pulse Source at the Stanford Linear-Accelerator Center we solved this problem by measuring the arrival time of each high energy electron bunch with electro-optic sampling. This measurement indirectly determined the arrival time of each x-ray pulse relative to an external pump laser pulse with a time resolution of better than 60 fs rms.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...