Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Life (Basel) ; 14(1)2024 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-38255747

RESUMO

BACKGROUND: Safety, efficacy, and patient comfort are the expectations during pulmonary vein isolation (PVI). We aimed to validate the combined advantages of pre- and periprocedural anticoagulation with non-vitamin K anticoagulants (NOACs) and rigorous left atrial appendage thrombus (LAAT) exclusion with computed tomography (CT). METHODS: This study included a population of consecutive patients, between March 2018 and June 2020, who underwent cardiac CT within 24 h before PVI to guide the ablation and rule out LAAT. NOAC was omitted 24 h before the ablation. RESULTS: A total of 187 patients (63% male) underwent CT before PVI. None of the patients experienced stroke during or after the procedure. The complication rate was low, with no thromboembolic events and 2.1% of patients experiencing a major bleeding event. CONCLUSIONS: Omitting NOAC 24 h before the ablation might be safe if combined with left atrial thrombus exclusion with computed tomography.

2.
Front Cardiovasc Med ; 10: 1185187, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37560116

RESUMO

Purpose: Our purpose was to compare the procedural characteristics, success rate, and complication rate of the conventional fluoroscopic (CF) and the zero-fluoroscopic (ZF) approach in patients undergoing catheter ablation of AVNRT or typical atrial flutter (Aflu). Methods: 186 consecutive patients with an indication for AVNRT or Aflu ablation were enrolled. Based on the operator's preference, the patients were assigned to either CF or ZF group. In the ZF group EnSite NavX, Carto3, or Rhythmia EAMS were used for catheter guidance. Results: The median age was 56 (IQR = 42-68) years, 144 patients had AVNRT, and 42 had Aflu ablation. CF approach was chosen in 123 cases, while ZF in 63 cases. ZF approach was used more often in case of AVNRT patients [56 (39%) vs. 7 (17%), p = 0.006] and in the case of female patients [43 (68%) vs. 20 (32%), p = 0.008]. Acute procedural success was obtained in all cases. There was no difference in the complication rate (1 vs. 1, p > 0.99) between the two groups. No difference was found regarding the procedure time between the CF and ZF groups [CF: 55 (46-60) min, ZF 60 (47-65) min; p = 0.487] or in the procedure time for the different EAMS [EnSite NavX: 58 (50-63) min, Carto3: 60 (44.5-66.3) min, Rhythmia: 55 (35-69) min; p = 0.887]. A similar success rate was seen at the 3-month follow-up in the two groups [41 (100%) vs. 96 (97%); p = 0.55]. Discussion: The ZF approach demonstrated non-inferiority in safety and efficacy compared with CF for the AVNRT and Aflu ablations.

3.
Coron Artery Dis ; 34(1): 18-23, 2023 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-36484216

RESUMO

BACKGROUND: Cardiac computed tomography (CT) is often performed before catheter ablation of atrial fibrillation to map atrial and pulmonary anatomy. Incident coronary artery disease (CAD) may also be diagnosed during cardiac CT angiography (CTA). Our aim was to assess whether coronary CTA might be able to identify a significant proportion of patients with obstructive CAD prior to their catheter ablation procedure event, even in asymptomatic patients. METHODS: Consecutive patients undergoing pre-ablation coronary CTA for atrial fibrillation between 2013 and 2020 were retrospectively selected. Patients with previously diagnosed CAD were excluded. Obstructive CAD was defined as ≥50% luminal stenosis. We analyzed the relationship between obstructive CAD, any chest pain, and traditional risk factors. RESULTS: Overall, 2321 patients [median age 63.0 (54.4-69.2), 1052/2321 (45.3%) female] underwent coronary CTA and 488/2321 (21.0%) were diagnosed with obstructive CAD. There was no difference regarding the rate of obstructive CAD in patients with any chest pain compared to patients without any chest pain [91/404 (22.5%) vs. 397/1917 (20.7%), P = 0.416, respectively). The following parameters were associated with obstructive CAD: age > 65 years [odds ratio (OR) = 2.51; 95% confidence interval (CI), 2.02-3.13; P < 0.001), male sex (OR = 1.59; 95% CI, 1.28-1.98; P < 0.001), hypertension (OR = 1.40; 95% CI, 1.08-1.81; P = 0.012), diabetes (OR = 1.50; 95% CI, 1.13-1.99; P = 0.006), dyslipidaemia (OR = 1.33; 95% CI, 1.07-1.66; P = 0.011) and history of smoking (OR = 1.34; 95% CI, 1.07-1.68; P = 0.011). CONCLUSIONS: The high prevalence of obstructive CAD even in patients without chest pain highlights the importance of additional coronary artery diagnostics in patients undergoing left atrial CTA awaiting catheter ablation for atrial fibrillation. These patients regardless of chest pain thus may require further risk modification to decrease their potential ischemic and thromboembolic risk.


Assuntos
Fibrilação Atrial , Doença da Artéria Coronariana , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Angiografia por Tomografia Computadorizada , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/epidemiologia , Doença da Artéria Coronariana/cirurgia , Estudos Retrospectivos , Dor no Peito
4.
Front Cardiovasc Med ; 9: 873135, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36225960

RESUMO

Background: The pathophysiology of persistent atrial fibrillation (AF) remains unclear. While several studies have demonstrated an association between myocardial infarction and atrial fibrillation, the role of stable coronary artery disease (CAD) is still unknown. As a result, we aimed to assess the association between CAD obstruction and AF recurrence after persistent AF ablation in patients with no history of CAD. Materials and methods: This observational retrospective study included consecutive patients who underwent routine preprocedural cardiac computed tomography (CCT) before persistent AF ablation between September 2015 and June 2018 in 5 European University Hospitals. Exclusion criteria were CAD or coronary revascularization previously known or during follow-up. Obstructive CAD was defined as luminal stenosis ≥ 50%. Results: All in all, 496 patients (mean age 61.8 ± 10.0 years, 76.2% males) were included. CHA2DS2-VASc score was 0 or 1 in 225 (36.3%) patients. Obstructive CAD was present in 86 (17.4%) patients. During the follow-up (24 ± 19 months), 207 (41.7%) patients had AF recurrence. The recurrence rate was not different between patients with and without obstructive CAD (43.0% vs. 41.5%, respectively; P = 0.79). When considering the location of the stenosis, the recurrence rate was higher in the case of left circumflex obstruction: 56% vs. 32% at 2 years (log-rank P ≤ 0.01). After Cox multivariate analysis, circumflex artery obstruction (HR 2.32; 95% CI 1.36-3.98; P < 0.01) was independently associated with AF recurrence. Conclusion: Circumflex artery obstruction detected with CCT was independently associated with 2-fold increase in the risk of AF recurrence after persistent AF ablation. Further research is necessary to evaluate this pathophysiological relationship.

5.
Front Cardiovasc Med ; 9: 935705, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35872909

RESUMO

Introduction: High-power short-duration (HPSD) radiofrequency ablation has been proposed to produce rapid and effective lesions for pulmonary vein isolation (PVI). We aimed to evaluate the procedural characteristics and the first-pass isolation (FPI) rate of HPSD and very high-power short-duration (vHPSD) ablation compared to the low-power long-duration (LPLD) ablation technique. Methods: One hundred fifty-six patients with atrial fibrillation (AF) were enrolled and assigned to LPLD, HPSD, or vHPSD PVI. The energy setting was 30, 50, and 90 W in the LPLD, HPSD, and vHPSD groups, respectively. In the vHPSD group, 90 W/4 s energy delivery was used in the QMODE+ setting. In the other groups, ablation index-guided applications were delivered with 30 W (LPLD) or 50 W (HPSD). Results: Bilateral PVI was achieved in all cases. Compared to the LPLD group, the HPSD and vHPSD groups had shorter procedure time [85 (75-101) min, 79 (65-91) min, and 70 (53-83) min], left atrial dwelling time [61 (55-70) min, 53 (41-56) min, and 45 (34-52) min], total RF time [1,567 (1,366-1,761) s, 1,398 (1,021-1,711) s, and 336 (247-386) s], but higher bilateral FPI rate (57, 78, and 80%) (all p-values < 0.01). The use of HPSD (OR = 2.72, 95% CI 1.15-6.44, p = 0.023) and vHPSD (OR = 2.90, 95% CI 1.24-6.44, p = 0.014) ablation techniques were associated with a higher probability of bilateral FPI. The 9-month AF-recurrence rate was lower in case of HPSD and vHPSD compared to LPLD ablation (10, 8, and 36%, p = 0.0001). Moreover, the presence of FPI was associated with a lower AF-recurrence rate at 9-month (OR = 0.09, 95% CI 0.04-0.24, p = 0.0001). Conclusion: Our prospective, observational cohort study showed that both HPSD and vHPSD RF ablation shortens procedure and RF time and results in a higher rate of FPI compared to LPLD ablation. Moreover, the use of HPSD and vHPSD ablation increased the acute and mid-term success rate. No safety concerns were raised for HPSD or vHPSD ablation in our study.

6.
Heart Vessels ; 37(10): 1769-1775, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35554635

RESUMO

Comparative data are virtually missing about the performance of different electro-anatomical mapping (EAM) system platforms on outflow tract (OT) premature ventricular complex (PVC) ablation outcomes with manual ablation catheters. We aimed to compare the acute success-, complication-, and long-term recurrence rates of impedance-based (IMP) and magnetic field-based (MAG) EAM platforms in manual OT PVC ablation. Single-centre, propensity score matched data of 39-39 patients ablated for OT PVCs in 2015-17 with IMP or MAG platforms were analysed. Acute success rate, peri-procedural complications, post-ablation daily PVC burden, and long-term recurrence rates were compared on intention-to-treat basis. Acute success rate was similar in the IMP and MAG group (77 vs. 82%, p = 0.78). There was a single case of femoral pseudo-aneurysm and no cardiac tamponade occurred. PVC burden fell significantly from baseline 24.0% [15.0-30.0%] to 3.3% [0.25-10.5%] (p < 0.001) post-ablation, with no difference between EAM platforms (IMP: 2.6% [0.5-12.0%] vs. MAG: 4.0% [2.0-6.5%]; p = 0.60). There was no significant difference in recurrence-free survival of the intention-to-treat cohort of the IMP and MAG groups (54 vs. 60%, p = 0.82, respectively) during 12 months of follow-up. Ablation with the aid of both impedance- and magnetic field-based EAM platforms can considerably reduce OT PVC burden and give similar acute- and long-term freedom from arrhythmia.


Assuntos
Ablação por Cateter , Complexos Ventriculares Prematuros , Humanos , Ablação por Cateter/efeitos adversos , Impedância Elétrica , Campos Magnéticos , Resultado do Tratamento , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia
7.
Front Cardiovasc Med ; 9: 708298, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35242821

RESUMO

INTRODUCTION: The role of the spatial relationship between the left superior pulmonary vein (LSPV) and left atrial appendage (LAA) is unknown. We sought to evaluate whether an abutting LAA and LSPV play a role in AF recurrence after catheter ablation for paroxysmal AF. METHODS: Consecutive patients, who underwent initial point-by-point radiofrequency catheter ablation for paroxysmal AF at the Heart and Vascular Center of Semmelweis University, Budapest, Hungary, between January of 2014 and December of 2017, were enrolled in the study. All patients underwent pre-procedural cardiac CT to assess left atrial (LA) and pulmonary vein (PV) anatomy. Abutting LAA-LSPV was defined as cases when the minimum distance between the LSPV and LAA was less than 2 mm. RESULTS: We included 428 patients (60.7 ± 10.8 years, 35.5% female) in the analysis. AF recurrence rate was 33.4%, with a median recurrence-free time of 21.2 (8.8-43.0) months. In the univariable analysis, female sex (HR = 1.45; 95%CI = 1.04-2.01; p = 0.028), LAA flow velocity (HR = 1.01; 95%CI = 1.00-1.02; p = 0.022), LAA orifice area (HR = 1.00; 95%CI = 1.00-1.00; p = 0.028) and abutting LAA-LSPV (HR = 1.53; 95%CI = 1.09-2.14; p = 0.013) were associated with AF recurrence. In the multivariable analysis, abutting LAA-LSPV (adjusted HR = 1.55; 95%CI = 1.04-2.31; p = 0.030) was the only independent predictor of AF recurrence. CONCLUSION: Abutting LAA-LSPV predisposes patients to have a higher chance for arrhythmia recurrence after catheter ablation for paroxysmal AF.

8.
Eur Heart J Cardiovasc Imaging ; 23(4): 515-523, 2022 03 22.
Artigo em Inglês | MEDLINE | ID: mdl-33693618

RESUMO

AIMS: Controversial results have been published regarding the influence of pulmonary vein (PV) anatomical variations on outcomes after pulmonary vein isolation (PVI). However, no data are available on the impact of PV orientation on the long-term success rates of point-by-point PVI. We sought to determine the impact of PV anatomy and orientation on atrial fibrillation (AF)-free survival in patients undergoing PVI using the radiofrequency point-by-point technique. METHODS AND RESULTS: We retrospectively included 448 patients who underwent initial point-by-point radiofrequency ablation for AF at our department. Left atrial computed tomography angiography was performed before each procedure. PV anatomical variations, ostial parameters (area, effective diameter, and eccentricity), orientation, and their associations with 24-month AF-free survival were analysed. PV anatomical variations and ostial parameters were not predictive for AF-free survival (all P > 0.05). Univariate analysis showed that female sex (P = 0.025) was associated with higher rates of AF recurrence, ventral-caudal (P = 0.002), dorsal-cranial (P = 0.034), and dorsal-caudal (P = 0.042) orientation of the right superior PV (RSPV), on the other hand, showed an association with lower rates of AF recurrence, when compared with the reference ventral-cranial orientation. On multivariate analysis, both female sex [odds ratio (OR) 1.83, 95% CI 1.15-2.93, P = 0.011] and ventral-caudal RSPV orientation, compared with ventral-cranial orientation, proved to be independent predictors of 24-month AF recurrence (OR 0.37, 95% CI 0.19-0.71, P = 0.003). CONCLUSION: Female sex and ventral-caudal RSPV orientation have an impact on long-term arrhythmia-free survival. Assessment of PV orientation may be a useful tool in predicting AF-free survival and may contribute to a more personalized management of AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Feminino , Humanos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Estudos Retrospectivos , Resultado do Tratamento
9.
Clin Cardiol ; 45(3): 273-281, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34799870

RESUMO

INTRODUCTION: There are no consistently confirmed predictors of atrial fibrillation (AF) recurrence after catheter ablation. Therefore, we aimed to study whether left atrial appendage volume (LAAV) and function influence the long-term recurrence of AF after catheter ablation, depending on AF type. METHODS: AF patients who underwent point-by-point radiofrequency catheter ablation after cardiac computed tomography (CT) were included in this analysis. LAAV and LAA orifice area were measured by CT. Uni- and multivariable Cox proportional hazard regression models were performed to determine the predictors of AF recurrence. RESULTS: In total, 561 AF patients (61.9 ± 10.2 years, 34.9% females) were included in the study. Recurrence of AF was detected in 40.8% of the cases (34.6% in patients with paroxysmal and 53.5% in those with persistent AF) with a median recurrence-free time of 22.7 (9.3-43.1) months. Patients with persistent AF had significantly higher body surface area-indexed LAV, LAAV, and LAA orifice area and lower LAA flow velocity, than those with paroxysmal AF. After adjustment left ventricular ejection fraction (LVEF) <50% (HR = 2.17; 95% CI = 1.38-3.43; p < .001) and LAAV (HR = 1.06; 95% CI = 1.01-1.12; p = .029) were independently associated with AF recurrence in persistent AF, while no independent predictors could be identified in paroxysmal AF. CONCLUSION: The current study demonstrates that beyond left ventricular systolic dysfunction, LAA enlargement is associated with higher rate of AF recurrence after catheter ablation in persistent AF, but not in patients with paroxysmal AF.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Ablação por Cateter , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Feminino , Humanos , Masculino , Recidiva , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
10.
Am J Physiol Heart Circ Physiol ; 321(4): H784-H797, 2021 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-34533403

RESUMO

Coenzyme A (CoA) is an essential cofactor required for intermediary metabolism. Perturbations in homeostasis of CoA have been implicated in various pathologies; however, whether CoA homeostasis is changed and the extent to which CoA levels contribute to ventricular function and remodeling during pressure overload has not been explored. In this study, we sought to assess changes in CoA biosynthetic pathway during pressure overload and determine the impact of limiting CoA on cardiac function. We limited cardiac CoA levels by deleting the rate-limiting enzyme in CoA biosynthesis, pantothenate kinase 1 (Pank1). We found that constitutive, cardiomyocyte-specific Pank1 deletion (cmPank1-/-) significantly reduced PANK1 mRNA, PANK1 protein, and CoA levels compared with Pank1-sufficient littermates (cmPank1+/+) but exerted no obvious deleterious impact on the mice at baseline. We then subjected both groups of mice to pressure overload-induced heart failure. Interestingly, there was more ventricular dilation in cmPank1-/- during the pressure overload. To explore potential mechanisms contributing to this phenotype, we performed transcriptomic profiling, which suggested a role for Pank1 in regulating fibrotic and metabolic processes during the pressure overload. Indeed, Pank1 deletion exacerbated cardiac fibrosis following pressure overload. Because we were interested in the possibility of early metabolic impacts in response to pressure overload, we performed untargeted metabolomics, which indicated significant changes to metabolites involved in fatty acid and ketone metabolism, among other pathways. Collectively, our study underscores the role of elevated CoA levels in supporting fatty acid and ketone body oxidation, which may be more important than CoA-driven, enzyme-independent acetylation in the failing heart.NEW & NOTEWORTHY Changes in CoA homeostasis have been implicated in a variety of metabolic diseases; however, the extent to which changes in CoA homeostasis impacts remodeling has not been explored. We show that limiting cardiac CoA levels via PANK deletion exacerbated ventricular remodeling during pressure overload. Our results suggest that metabolic alterations, rather than structural alterations, associated with Pank1 deletion may underlie the exacerbated cardiac phenotype during pressure overload.


Assuntos
Metabolismo Energético , Miocárdio/enzimologia , Fosfotransferases (Aceptor do Grupo Álcool)/deficiência , Disfunção Ventricular Esquerda/enzimologia , Função Ventricular Esquerda , Remodelação Ventricular , Animais , Aorta/fisiopatologia , Aorta/cirurgia , Apoptose , Pressão Arterial , Coenzima A/metabolismo , Modelos Animais de Doenças , Feminino , Fibrose , Deleção de Genes , Humanos , Masculino , Metaboloma , Camundongos Endogâmicos C57BL , Camundongos Knockout , Miocárdio/patologia , Fosfotransferases (Aceptor do Grupo Álcool)/genética , Transcriptoma , Disfunção Ventricular Esquerda/genética , Disfunção Ventricular Esquerda/patologia , Disfunção Ventricular Esquerda/fisiopatologia
11.
Dis Markers ; 2021: 5511267, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34257744

RESUMO

BACKGROUND: The burden and persistence of atrial fibrillation (AF) have been associated with the presence and extent of left atrial (LA) fibrosis. Recent reports have implicated an association between the extent of LA fibrosis and the outcome of pulmonary vein isolation (PVI). We aimed to analyse the value of an automated scar quantification method in the prediction of success following PVI. METHODS: One hundred and nine consecutive patients undergoing PVI for paroxysmal or persistent AF were included in our observational study with a 2-year follow-up. Prior to PVI, patients underwent high-definition LA electroanatomical mapping, and scar burden was quantified by automated software (Voltage Histogram Analysis, CARTO 3, Biosense Webster), then classified into 4 subgroups (Dublin Classes I-IV). Recurrence rates were analysed on and off antiarrhythmic drug therapy (AAD), respectively. RESULTS: The overall success rate was 74% and 67% off AAD at 1- and 2-year follow-up, respectively. Patients with Dublin Class IV had significantly lower success rates (p = 0.008, off AAD). Dublin Class IV (OR = 2.27, p = 0.022, off AAD) and the presence of arrhythmia in the blanking period (OR = 3.28, p = 0.001, off AAD) were the only significant predictors of recurrence. The use of AAD did not affect these results. CONCLUSIONS: We propose a classification of low voltage areas based on automated quantification by software during 3D mapping prior to PVI. Patients with high burden of low voltage areas (>31% of <0.5 mV, Dublin Class IV) have a higher risk of recurrence following PVI. Information gathered during electroanatomical mapping may have important prognostic value.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Regras de Decisão Clínica , Átrios do Coração/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/patologia , Angiografia por Tomografia Computadorizada , Ecocardiografia , Eletrocardiografia , Feminino , Fibrose , Seguimentos , Átrios do Coração/cirurgia , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Gravidade do Paciente , Modelos de Riscos Proporcionais , Recidiva , Estudos Retrospectivos , Resultado do Tratamento
13.
Europace ; 23(4): 596-602, 2021 04 06.
Artigo em Inglês | MEDLINE | ID: mdl-33576378

RESUMO

AIMS: Unlike in atrial fibrillation ablation, there is a lack of appropriately sized and properly designed studies regarding outflow tract (OT) premature ventricular complex (PVC) ablation outcomes with contact force sensing (CFS) catheters. We aimed to compare the acute success-, complication-, and long-term recurrence rates of manual CFS catheters with traditional irrigated catheters (T) in OT PVC ablation. METHODS AND RESULTS: Single-centre, propensity-matched data of 75-75 patients ablated for right-sided OT (RVOT) or left-sided OT (LVOT) PVCs in 2015-17 with CFS or T catheters were compared. Acute success rate, peri-procedural complications, post-procedural daily PVC burden, and long-term recurrence rates were compared on intention-to-treat basis. Acute success rate equalled 80% in both groups, with no difference in force values in the CFS group comparing successful or failed cases [12.0 (8.75-17.0) vs. 16.0 (10.25-22.25) g, P = 0.21]. There were three cases of pseudo-aneurysm and one cardiac tamponade. PVC burden fell significantly from baseline 22 (15-30)% to 2 (0-10)% (P < 0.0001), with no difference between catheter types [CFS: 1 (0-7)% vs. T: 4 (1-12) %; P = 0.21]. There was no significant difference in recurrence-free survival of CFS and T catheters (58 vs. 59%, P = 0.29) during 12 months of follow-up, respectively. Recurrence in the CFS group did not differ either by the force exerted below or above the median value of 12 g (P = 0.66). CONCLUSION: Both types of catheters can effectively reduce OT PVC burden with minimal serious complication rates. Ablation with CFS or T catheters gives similar acute- and long-term results.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Complexos Ventriculares Prematuros , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Catéteres , Humanos , Resultado do Tratamento , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia
14.
Cardiol Res Pract ; 2020: 3981684, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32855820

RESUMO

INTRODUCTION: Growing evidence suggests that fibrotic changes can be observed in atrial fibrillation (AF) in both atria. Quantification of the scar burden during electroanatomical mapping might have important therapeutic and prognostic consequences. However, as the current invasive treatment of AF is focused on the left atrium (LA), the role of the right atrium (RA) is less well understood. We aimed to characterize the clinical determinates of the RA low-voltage burden and its relation to the LA scaring. METHODS: We have included 36 patients who underwent catheter ablation for AF in a prospective observational study. In addition to LA mapping and ablation, high-density RA bipolar voltage maps (HD-EAM) were also reconstructed. The extent of the diseased RA tissue (≤0.5 mV) was quantified using the voltage histogram analysis tool (CARTO®3, Biosense Webster). RESULTS: The percentage of RA diseased tissue burden was significantly higher in patients with a CHA2DS2-VASc score ≥ 2 (p = 0.0305), higher indexed LA volume on the CTA scan and on the HD-EAM (p = 0.0223 and p = 0.0064, respectively), or higher indexed RA volume on the HD-EAM (p = 0.0026). High RA diseased tissue burden predicted the presence of high LA diseased tissue burden (OR = 7.1, CI (95%): 1.3-38.9, p = 0.0145), and there was a significant correlation of the same (r = 0.6461, p < 0.0001). CONCLUSIONS: Determining the extent of the right atrial low-voltage burden might give useful clinical information. According to our results, the diseased tissue burden correlates well between the two atria: the right atrium mirrors the left atrium.

15.
J Interv Card Electrophysiol ; 59(1): 5-12, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31165967

RESUMO

PURPOSE: Left atrial (LA) fibrosis plays an important role in the pathogenesis and perpetuation of atrial fibrillation (AF). It may be identified by bipolar voltage (BiV) mapping, but quantification of fibrosis which previously relied on visual estimation of scar has been shown to be inaccurate. Our aim was to use a novel automated voltage histogram analysis (VHA) tool to quantify LA scar burden accurately in patients with AF. METHODS: LA voltage was assessed in 100 consecutive patients undergoing first pulmonary vein isolation (PVI) for paroxysmal or persistent AF using a circular multielectrode catheter to create high-density LA BiV maps which were analysed using the VHA tool after the procedure. RESULTS: High-density electro-anatomic maps took 10 min to create and contained a median of 1049 points. The VHA algorithm accurately quantified the burden of Diseased LA Tissue (≤ 0.5 mV) and Dense LA Scar (≤ 0.2 mV) with a median of 17.8% and 3.5% respectively. A quartile classification was applied based on diseased LA tissue burden. Patients in class IV with the highest diseased LA burden were older (p < 0.0001), more likely female (p = 0.0095), had higher CHA2DS2-VASc scores (p = 0.0024) and were more likely to have persistent rather than paroxysmal AF (p = 0.0179) than those in classes I-III. CONCLUSIONS: The VHA algorithm is able to quantify percentage surface area voltage rapidly and according to preset ranges for the first time. The algorithm offers the potential for classification of patients undergoing AF ablation into different classes of diseased LA burden, which may have diagnostic, therapeutic and prognostic implications.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/patologia , Fibrilação Atrial/cirurgia , Cicatriz/patologia , Feminino , Átrios do Coração/cirurgia , Humanos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia
16.
Europace ; 21(8): 1237-1245, 2019 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-31168608

RESUMO

AIMS: The aim of our study was to investigate the long-term efficacy and safety of transseptal endocardial left ventricular lead implantation (TELVLI). METHODS AND RESULTS: Transseptal endocardial left ventricular lead implantation was performed in 54 patients (44 men, median age 69, New York Heart Association III-IV stage) between 2007 and 2017 in a single centre. In 36 cases, the transseptal puncture (TP) was performed via the femoral vein, and in 18 cases, the TP and also the left ventricular (LV) lead placement were performed via the subclavian vein. An electrophysiological deflectable catheter was used to reach the LV wall through the dilated TP hole. The LV lead implantation was successful in all patients. A total of 54 patients were followed up for a median of 29 months [interquartile range (IQR) 8-40 months], the maximum follow-up time was 94 months. Significant improvement in the LV ejection fraction was observed at the 3-month visit, from the median of 27% (IQR 25-34%) to 33% (IQR 32-44%), P < 0.05. Early lead dislocation was observed in three cases (5%), reposition was performed using the original puncture site in all. The patients were maintained on anticoagulation therapy with a target international normalized ratio between 2.5 and 3.5. Four thromboembolic events were noticed during follow-up. A total of 27 patients died, with a median survival of 15 months (IQR 6-40). CONCLUSION: The TELVLI is an effective approach for cardiac resynchronization therapy (CRT) however it is associated with a substantial thromboembolic risk (7%).


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/terapia , Septos Cardíacos/cirurgia , Complicações Pós-Operatórias/epidemiologia , Implantação de Prótese , Tromboembolia , Idoso , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/métodos , Eletrodos Implantados/efeitos adversos , Falha de Equipamento , Feminino , Ventrículos do Coração/cirurgia , Humanos , Hungria , Masculino , Avaliação de Processos e Resultados em Cuidados de Saúde , Implantação de Prótese/efeitos adversos , Implantação de Prótese/instrumentação , Implantação de Prótese/métodos , Retenção da Prótese/métodos , Retenção da Prótese/estatística & dados numéricos , Tromboembolia/epidemiologia , Tromboembolia/etiologia
17.
Orv Hetil ; 160(14): 540-548, 2019 Apr.
Artigo em Húngaro | MEDLINE | ID: mdl-30931601

RESUMO

INTRODUCTION: Levels of cardiac necroenzymes, high-sensitive troponin (hsTnT) and creatine kinase muscle-brain (CKMB) increase as a result of a myocardial damage following catheter ablation. AIM: To analyze the mid-term alteration of hsTnT and CKMB levels following radiofrequency ablation (RFCA) for atrial fibrillation (AF), atrial flutter (AFlu), AV-nodal reentry tachycardia (AVNRT) and electrophysiological studies (EPS) without ablation. METHOD: Patients undergoing RFCA for various indications and EPS were consecutively enrolled in our prospective study. Concentrations of hsTnT and CKMB were measured from serial blood samples directly before and after the procedure, 4 and 20 hours later and at 3 months follow-up. RESULTS: Forty-seven patients (10 EPS, 12 AVNRT, 13 AFlu, 12 AF) with mean age of 55 ± 13 were included. hsTnT levels increased significantly in all groups after the procedures, while CKMB changed only in the AF group. hsTnT exceeded the reference value in all patients with ablation and in 80% of patients with EPS 4 hours post-ablation. Peak average hsTnT levels for EPS, AVNRT, AFlu were 24 ± 11, 260 ± 218 and 541 ± 233 ng/L, respectively. The highest hsTnT level was measured in the AF group (799 ± 433 ng/L). We found a positive correlation between hsTnT levels and ablation time after RFCA. CONCLUSIONS: The hsTnT levels significantly change after EPS and RFCA, in all patients who underwent ablation, and in 80% of those with EPS had hsTnT positivity in the early post-procedural phase. hsTnT levels depended significantly on the type of the subgroups and correlated with the ablation time. Awareness of those observations is essential to correctly interpret elevated hsTnT levels following RFCA. Orv Hetil. 2019; 160(14): 540-548.


Assuntos
Arritmias Cardíacas/cirurgia , Ablação por Cateter/efeitos adversos , Infarto do Miocárdio/complicações , Adulto , Idoso , Arritmias Cardíacas/sangue , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Flutter Atrial/fisiopatologia , Flutter Atrial/cirurgia , Biomarcadores/sangue , Ablação por Cateter/métodos , Creatina Quinase Mitocondrial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Ablação por Radiofrequência , Resultado do Tratamento , Troponina/sangue
18.
Europace ; 21(5): 732-737, 2019 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-30689857

RESUMO

AIMS: Atrial fibrillation (AF) ablation has made huge progress with respect to innovation, efficacy, and safety, however, complications are still present. Recent studies examined various predictors of complications. However, limited data exist regarding the role of a repeat procedure. Our aim was the prospective evaluation of the incidence and predictors of complications related to AF ablation procedures in consecutive patients, including repeat procedures. METHODS AND RESULTS: All ablation procedures for AF between January 2013 and December 2015 were analysed in our electrophysiology laboratory. During the study period 1243 procedures were analysed [394 female, median age 62 (55-69)]. Overall complication rate was 6.84%, major complication rate was 2.82%. Major complications were the following: 18 pericardial tamponades; 5 pseudoaneurysms; 1 arteriovenous fistula; 6 thromboembolic cerebrovascular events; 3 pulmonary vein stenosis; and 2 atrioventricular blocks. No atrio-oesophageal fistula or procedure related death occurred. Univariate analysis for overall complications showed that age ≥ 65 years (P = 0.0231), female gender (P = 0.0438), hypertension (P = 0.0488), CHA2DS2-VASc score ≥ 2 (P = 0.0156), and previous AF ablation procedure (P < 0.0001) is associated with higher risk for adverse events. Multivariate analysis showed that the only independent predictor of overall complications was previous AF ablation procedure (P < 0.0001). Similarly, the only predictor of major complications was previous AF ablation procedure (P < 0.0001). CONCLUSION: Incidence of complications associated with AF ablation in our high volume electrophysiology laboratory is similar to other cohorts. The only independent predictor of complications was previous AF ablation procedure in our series.


Assuntos
Falso Aneurisma , Fibrilação Atrial , Tamponamento Cardíaco , Ablação por Cateter/efeitos adversos , Embolia Intracraniana , Complicações Intraoperatórias , Retratamento , Idoso , Falso Aneurisma/epidemiologia , Falso Aneurisma/etiologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Tamponamento Cardíaco/epidemiologia , Tamponamento Cardíaco/etiologia , Ablação por Cateter/métodos , Feminino , Humanos , Embolia Intracraniana/epidemiologia , Embolia Intracraniana/etiologia , Complicações Intraoperatórias/diagnóstico , Complicações Intraoperatórias/epidemiologia , Masculino , Avaliação de Resultados em Cuidados de Saúde , Prognóstico , Retratamento/efeitos adversos , Retratamento/métodos , Retratamento/estatística & dados numéricos , Medição de Risco , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...