Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Nano Lett ; 24(19): 5913-5919, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38710045

RESUMO

Electrical resistivity is the key parameter in the active regions of many current nanoscale devices, from memristors to resistive random-access memory and phase-change memories. The local resistivity of the materials is engineered on the nanoscale to fit the performance requirements. Phase-change memories, for example, rely on materials whose electrical resistance increases dramatically with a change from a crystalline to an amorphous phase. Electrical characterization methods have been developed to measure the response of individual devices, but they cannot map the local resistance across the active area. Here, we propose a method based on operando electron holography to determine the local resistance within working devices. Upon switching the device, we show that electrical resistance is inhomogeneous on the scale of only a few nanometers.

2.
Microscopy (Oxf) ; 70(1): 47-58, 2021 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-32744626

RESUMO

We investigate the effect that recording off-axis electron holograms on pixelated detectors, such as charge-coupled devices (CCD) and direct-detection devices (DDD), can have on measured amplitudes and phases. Theory will be developed for the case of perfectly uniform interference fringes illuminating an imperfect detector with gain variations and pixel displacements. We will show that both these types of defect produce a systematic noise in the phase images that depends on the position of the holographic fringes with respect to the detector. Subtracting a reference hologram from the object hologram will therefore not remove the phase noise if the initial phases of the two holograms do not coincide exactly. Another finding is that pi-shifted holograms are much less affected by gain variations but show no improvement concerning geometric distortions. The resulting phase errors will be estimated and simulations presented that confirm the theoretical developments.

3.
Nano Lett ; 19(12): 9160-9169, 2019 12 11.
Artigo em Inglês | MEDLINE | ID: mdl-31756108

RESUMO

The one-step seed-mediated synthesis is widely used for the preparation of ferromagnetic metal nanoparticles (NPs) since it offers a good control of particle morphology. Nevertheless, this approach suffers from a lack of mechanistic studies because of the difficulties of following in real time the heterogeneous nucleation and predicting structure effects with seeds that are generated in situ. Here, we propose a complete scheme of the heteronucleation process involved in one-pot seed-mediated syntheses of cobalt nanoparticles in liquid polyols, relying on geometrical phase analysis (GPA) of high-resolution high-angle annular dark field (HAADF)-STEM images and in situ measurements of the molecular hydrogen evolution. Cobalt particles of different shapes (rods, platelets, or hourglass-like particles) were grown by reducing cobalt carboxylate in liquid polyols in the presence of iridium or ruthenium chloride as the nucleating agent. A reaction scheme was established by monitoring the H2 evolution resulting from the decomposition of metal hydrides, formed in situ by ß-elimination of metal alkoxides, and from the polyol dehydrogenation, catalytically activated by the metal particles. This is a very good probe for both the noble metal nucleation and the heterogeneous nucleation of cobalt, showing a good separation of these two steps. Ir and Ru seeds with a size in the range 1-2 nm were found exactly in the center of the cobalt particles, whatever the cobalt particle shape, and high-resolution images revealed an epitaxial growth of the hcp Co on fcc Ir or hcp Ru seeds. The microstructure analysis around the seeds made evident two different ways of relaxing the lattice mismatch between the seeds and the cobalt, with the presence of dislocations around the Ir seeds and compression zones of the cobalt lattice near the Ru seeds. The relationship between the nature of the nucleating agent, the reaction steps, and the microstructure is discussed.

4.
Sci Rep ; 7(1): 12394, 2017 09 29.
Artigo em Inglês | MEDLINE | ID: mdl-28963544

RESUMO

A bewildering number of techniques have been developed for transmission electron microscopy (TEM), involving the use of ever more complex combinations of lens configurations, apertures and detector geometries. In parallel, the developments in the field of ion beam instruments have modernized sample preparation and enabled the preparation of various types of materials. However, the desired final specimen geometry is always almost the same: a thin foil of uniform thickness. Here we will show that judicious design of specimen geometry can make all the difference and that experiments can be carried out on the most basic electron microscope and in the usual imaging modes. We propose two sample preparation methods that allow the formation of controlled moiré patterns for general monocrystalline structures in cross-section and at specific sites. We developed moiré image treatment algorithms using an absolute correction of projection lens distortions of a TEM that allows strain measurements and mapping with a nanometer resolution and 10-4 precision. Imaging and diffraction techniques in other fields may in turn benefit from this technique in perspective.

5.
Nanotechnology ; 28(27): 275201, 2017 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-28612754

RESUMO

We present a study of blue III-nitride light-emitting diodes (LEDs) with multiple quantum well (MQW) and quantum dot (QD) active regions (ARs), comparing experimental and theoretical results. The LED samples were grown by metalorganic vapor phase epitaxy, utilizing growth interruption in the hydrogen/nitrogen atmosphere and variable reactor pressure to control the AR microstructure. Realistic configuration of the QD AR implied in simulations was directly extracted from HRTEM characterization of the grown QD-based structures. Multi-scale 2D simulations of the carrier transport inside the multiple QD AR have revealed a non-trivial pathway for carrier injection into the dots. Electrons and holes are found to penetrate deep into the multi-layer AR through the gaps between individual QDs and get into the dots via their side edges rather than via top and bottom interfaces. This enables a more homogeneous carrier distribution among the dots situated in different layers than among the laterally uniform quantum well (QWs) in the MQW AR. As a result, a lower turn-on voltage is predicted for QD-based LEDs, as compared to MQW ones. Simulations did not show any remarkable difference in the efficiencies of the MQW and QD-based LEDs, if the same recombination coefficients are utilized, i.e. a similar crystal quality of both types of LED structures is assumed. Measurements of the current-voltage characteristics of LEDs with both kinds of the AR have shown their close similarity, in contrast to theoretical predictions. This implies the conventional assumption of laterally uniform QWs not to be likely an adequate approximation for the carrier transport in MQW LED structures. Optical characterization of MQW and QD-based LEDs has demonstrated that the later ones exhibit a higher efficiency, which could be attributed to better crystal quality of the grown QD-based structures. The difference in the crystal quality explains the recently observed correlation between the growth pressure of LED structures and their efficiency and should be taken into account while further comparing performances of MQW and QD-based LEDs. In contrast to experimental results, our simulations did not reveal any advantages of using QD-based ARs over the MQW ones, if the same recombination constants are assumed for both cases. This fact demonstrates importance of accounting for growth-dependent factors, like crystal quality, which may limit the device performance. Nevertheless, a more uniform carrier injection into multi-layer QD ARs predicted by modeling may serve as the basis for further improvement of LED efficiency by lowering carrier density in individual QDs and, hence, suppressing the Auger recombination losses.

6.
Microscopy (Oxf) ; 66(3): 217-221, 2017 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-28339765

RESUMO

A moiré pattern is created in a scanning transmission electron microscope (STEM) when the scan step is close to a crystalline periodicity. Usually, fringes are visible in only one direction, corresponding to a single set of lattice planes, but fringes can be formed in two directions or more. Using an accurate independent calibration, the strains in silicon devices have been determined from the spacing and orientation of one-directional STEM moiré fringes. In this report, we first discuss the origin of the STEM moiré, and then we show how an accurate calibration of the scan step can be obtained from the STEM moiré pattern itself, providing that we know initially only an approximate scan step and the planar spacing. The new calibration scheme also makes the STEM moiré experiments easier, since it can be applied for the moiré where the scan direction is not precisely aligned with the crystalline lattice. Finally, we show how the two-dimensional strain information will be readily extracted from two one-directional moiré patterns using the concept of geometric phase.

7.
Nanotechnology ; 28(1): 015701, 2017 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-27897139

RESUMO

The impact of electromechanical coupling on optical properties of light-emitting diodes (LEDs) with InGaN/GaN quantum-dot (QD) active regions is studied by numerical simulations. The structure, i.e. the shape and the average In content of the QDs, has been directly derived from experimental data on out-of-plane strain distribution obtained from the geometric-phase analysis of a high-resolution transmission electron microscopy image of an LED structure grown by metalorganic vapor-phase epitaxy. Using continuum [Formula: see text] calculations, we have studied first the lateral and full electromechanical coupling between the QDs in the active region and its impact on the emission spectrum of a single QD located in the center of the region. Our simulations demonstrate the spectrum to be weakly affected by the coupling despite the strong common strain field induced in the QD active region. Then we analyzed the effect of vertical coupling between vertically stacked QDs as a function of the interdot distance. We have found that QCSE gives rise to a blue-shift of the overall emission spectrum when the interdot distance becomes small enough. Finally, we compared the theoretical spectrum obtained from simulation of the entire active region with an experimental electroluminescence (EL) spectrum. While the theoretical peak emission wavelength of the selected central QD corresponded well to that of the EL spectrum, the width of the latter one was determined by the scatter in the structures of various QDs located in the active region. Good agreement between the simulations and experiment achieved as a whole validates our model based on realistic structure of the QD active region and demonstrates advantages of the applied approach.

8.
Ultramicroscopy ; 160: 98-109, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26476802

RESUMO

Strain mapping is an active area of research in transmission electron microscopy. Here we introduce a dark-field electron holographic technique that shares several aspects in common with both off-axis and in-line holography. Two incident and convergent plane waves are produced in front of the specimen thanks to an electrostatic biprism in the condenser system of a transmission electron microscope. The interference of electron beams diffracted by the illuminated crystal is then recorded in a defocused plane. The differential phase recovered from the hologram is directly proportional to the strain in the sample. The strain can be quantified if the separation of the images due to the defocus is precisely determined. The present technique has the advantage that the derivative of the phase is measured directly which allows us to avoid numerical differentiation. The distribution of the noise in the reconstructed strain maps is isotropic and more homogeneous. This technique was used to investigate different samples: a Si/SiGe superlattice, transistors with SiGe source/drain and epitaxial PZT thin films.

9.
Ultramicroscopy ; 161: 23-40, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26624513

RESUMO

As proposed recently, a tilted reference wave in off-axis electron holography is expected to be useful for aberration measurement and correction. Furthermore, in dark-field electron holography, it is considered to replace the reference wave, which is conventionally diffracted in an unstrained object area, by a well-defined object-independent reference wave. Here, we first realize a tilted reference wave by employing a biprism placed in the condenser system above three condenser lenses producing a relative tilt magnitude up to 20/nm at the object plane (300kV). Paraxial ray-tracing predicts condenser settings for a parallel illumination at the object plane, where only one half of the round illumination disc is tilted relative to the optical axis without displacement. Holographic measurements verify the kink-like phase modulation of the incident beam and return the interference fringe contrast as a function of the relative tilt between both parts of the illumination. Contrast transfer theory including condenser aberrations and biprism instabilities was applied to explain the fringe contrast measurement. A first dark-field hologram with a tilted - object-free - reference wave was acquired and reconstructed. A new application for bright/dark-field imaging is presented.

10.
Micron ; 63: 2-8, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24702951

RESUMO

Cold-field emission properties of carbon cone nanotips (CCnTs) have been studied in situ in the transmission electron microscope (TEM). The current as a function of voltage, i(V), was measured and analyzed using the Fowler-Nordheim (F-N) equation. Off-axis electron holography was employed to map the electric field around the tip at the nanometer scale, and combined with finite element modeling, a quantitative value of the electric field has been obtained. For a tip-anode separation distance of 680 nm (measured with TEM) and a field emission onset voltage of 80 V, the local electric field was 2.55 V/nm. With this knowledge together with recorded i(V) curves, a work function of 4.8±0.3 eV for the CCnT was extracted using the F-N equation.

11.
Ultramicroscopy ; 136: 42-9, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24012934

RESUMO

Dark-field electron holography maps strain in crystal lattices into reconstructed phases over large fields of view. Here we investigate the details of the lattice strain-reconstructed phase relationship by applying dynamic scattering theory both analytically and numerically. We develop efficient analytic linear projection rules for 3D strain fields, facilitating a straight-forward calculation of reconstructed phases from 3D strained materials. They are used in the following to quantify the influence of various experimental parameters like strain magnitude, specimen thickness, excitation error and surface relaxation.

12.
Ultramicroscopy ; 115: 78-87, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22424716

RESUMO

A novel generalized linear transfer theory describing the signal and noise transfer in image detectors has been developed in Part I (Niermann, this issue, [1]) of this paper. Similar to the existing notion of a point spread function (PSF) describing the transfer of the first statistical moment (the average), a noise spread function (NSF) was introduced to characterize the spatially resolved transfer of noise (central second moment, covariance). Following the theoretic results developed in Part I (Niermann, this issue, [1]), a new experimental method based on single spot illumination has been developed and applied to measure 2D point and 4D noise spread functions of CCD cameras used in TEM. A dedicated oversampling method has been used to suppress aliasing in the measured quantities. We analyze the 4D noise spread with respect to electronic and photonic noise contributions.

13.
Phys Rev Lett ; 100(15): 156602, 2008 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-18518137

RESUMO

Aberration-corrected high-resolution transmission electron microscopy (HRTEM) is used to measure strain in a strained-silicon metal-oxide-semiconductor field-effect transistor. Strain components parallel and perpendicular to the gate are determined directly from the HRTEM image by geometric phase analysis. Si80Ge20 source and drain stressors lead to uniaxial compressive strain in the Si channel, reaching a maximum value of -1.3% just below the gate oxide, equivalent to 2.2 GPa. Strain maps obtained by linear elasticity theory, modeled with the finite-element method, agree with the experimental results to within 0.1%.

14.
Nature ; 453(7198): 1086-9, 2008 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-18563161

RESUMO

Strained silicon is now an integral feature of the latest generation of transistors and electronic devices because of the associated enhancement in carrier mobility. Strain is also expected to have an important role in future devices based on nanowires and in optoelectronic components. Different strategies have been used to engineer strain in devices, leading to complex strain distributions in two and three dimensions. Developing methods of strain measurement at the nanoscale has therefore been an important objective in recent years but has proved elusive in practice: none of the existing techniques combines the necessary spatial resolution, precision and field of view. For example, Raman spectroscopy or X-ray diffraction techniques can map strain at the micrometre scale, whereas transmission electron microscopy allows strain measurement at the nanometre scale but only over small sample areas. Here we present a technique capable of bridging this gap and measuring strain to high precision, with nanometre spatial resolution and for micrometre fields of view. Our method combines the advantages of moiré techniques with the flexibility of off-axis electron holography and is also applicable to relatively thick samples, thus reducing the influence of thin-film relaxation effects.

15.
Nat Mater ; 7(2): 120-4, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18084296

RESUMO

Metallic nanoparticles exhibit exceptional optoelectronic properties with applications in plasmonics, biosensing and nanomedicine. Recently, new synthesis techniques have enabled precise control over the sizes and shapes of metal nanoparticles, occasionally leading to morphologies that cannot be properly characterized using standard techniques. An example is five-fold-twinned decahedral Au nanoparticles, which are intrinsically strained as a result of their unique geometry. Various competing models have been proposed to predict the strain states of such nanoparticles. Here, we present a detailed analysis of the internal structure of a decahedral Au nanoparticle using aberration-corrected high-resolution electron microscopy and strain mapping. Our measurements confirm the presence of a disclination, which is consistent with the commonly accepted strain model. However, we also observed shear gradients, which are absent from the models. By comparing our local strain determinations with finite-element calculations, we show the effect of elastic anisotropy on the strain state in these nanoparticles.

16.
Nano Lett ; 7(10): 2942-50, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17845067

RESUMO

Key limitations of the colloidal semiconductor nanorods that have been reported so far are a significant distribution of lengths and diameters as well as the presence of irregular shapes produced by the current synthetic routes and, finally, the poor ability to fabricate large areas of oriented nanorod arrays. Here, we report a seeded-growth approach to the synthesis of asymmetric core-shell CdSe/CdS nanorods with regular shapes and narrow distributions of rod diameters and lengths, the latter being easily tunable up to 150 nm. These rods are highly fluorescent and show linearly polarized emission, whereby the emission energy depends mainly on the core diameter. We demonstrate their lateral alignment as well as their vertical self-alignment on substrates up to areas of several square micrometers.


Assuntos
Compostos de Cádmio/química , Cristalização/métodos , Nanotecnologia/métodos , Nanotubos/química , Nanotubos/ultraestrutura , Compostos de Selênio/química , Espectrometria de Fluorescência/métodos , Sulfetos/química , Substâncias Macromoleculares/química , Teste de Materiais , Conformação Molecular , Tamanho da Partícula , Propriedades de Superfície
17.
Biomacromolecules ; 8(4): 1319-26, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17348704

RESUMO

Lamellar square single crystals of V-amylose were obtained by adding alpha-naphthol to metastable dilute aqueous solutions of synthetic amylose chains with an average degree of polymerization of 100. The morphology and structure of the crystals were studied using low-dose transmission electron microscopy including high-resolution imaging, as well as electron and X-ray diffraction. The crystals are crystallized in a tetragonal P4(1)2(1)2 or P4(3)2(1)2 space group with unit cell parameters, calculated from X-ray diffraction data, a = b = 2.2844 nm (+/-0.0005) and c = 0.7806 nm (+/-0.001), implying the presence of two amylose chains per unit cell. High-resolution lattice images of the crystals confirmed that the amylose chains were crystallized as 8-fold helices corresponding to the repeat of four maltosyl units.


Assuntos
Amilose/química , Naftóis/química , Polímeros/química , Cristalização , Tamanho da Partícula , Polímeros/síntese química , Difração de Raios X
18.
Proc Natl Acad Sci U S A ; 101(52): 17936-9, 2004 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-15608057

RESUMO

Low-angle grain boundaries (LAGBs) are ubiquitous in natural and man-made materials and profoundly affect many of their mechanical, chemical, and electrical properties. The properties of LAGBs are understood in terms of their constituent dislocations that accommodate the small misorientations between grains. Discrete dislocations result in a heterogeneous local structure along the boundary. In this article, we report the lattice rotation across a LAGB in olivine (Mg(1.8)Fe(0.2)SiO(4)) measured at the nanometer scale by using quantitative high-resolution transmission electron microscopy. The analysis reveals a grain boundary that is corrugated. Elastic calculations show that this waviness is independent of the host material and thus a general feature of LAGBs. Based on our observations and analysis, we provide equations for the boundary position, local curvature, and the lattice rotation field for any LAGB. These results provide the basis for a reexamination of grain-boundary properties in materials such as high-temperature superconductors, nanocrystalline materials, and naturally deformed minerals.


Assuntos
Geologia/métodos , Compostos de Ferro/química , Compostos de Magnésio/química , Microscopia Eletrônica de Transmissão/métodos , Nanotecnologia/métodos , Silicatos/química , Cristalografia , Planeta Terra , Microscopia Eletrônica , Modelos Teóricos
19.
Microsc Res Tech ; 64(5-6): 390-402, 2004 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-15549694

RESUMO

A selection of recent results illustrating the application of off-axis electron holography to the study of magnetic microstructure in closely-spaced nanoparticles and nanowires is reviewed. Examples are taken from the characterization of FeNi nanoparticle chains, Co nanoparticle rings, two-dimensional arrays of naturally occurring magnetite crystals in minerals, and single crystalline Co nanowires. Approaches that can be used to separate the magnetic signal of interest from the mean inner potential contribution to the measured holographic phase shift are described, and the spatial and phase resolution that can be achieved are discussed.


Assuntos
Algoritmos , Elétrons , Análise de Fourier , Holografia/métodos , Modelos Teóricos , Nanoestruturas/química , Simulação por Computador , Magnetismo
20.
Nature ; 423(6937): 270-3, 2003 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-12748637

RESUMO

Defects and their associated long-range strain fields are of considerable importance in many areas of materials science. For example, a major challenge facing the semiconductor industry is to understand the influence of defects on device operation, a task made difficult by the fact that their interactions with charge carriers can occur far from defect cores, where the influence of the defect is subtle and difficult to quantify. The accurate measurement of strain around defects would therefore allow more detailed understanding of how strain fields affect small structures-in particular their electronic, mechanical and chemical properties--and how such fields are modified when confined to nanometre-sized volumes. Here we report the measurement of displacements around an edge dislocation in silicon using a combination of high-resolution electron microscopy and image analysis inherited from optical interferometry. The agreement of our observations with anisotropic elastic theory calculations is better than 0.03 A. Indeed, the results can be considered as an experimental verification of anisotropic theory at the near-atomic scale. With the development of nanostructured materials and devices, we expect the use of electron microscopy as a metrological tool for strain analysis to become of increasing importance.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA