Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Struct Dyn ; 3(5): 051101, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27704034

RESUMO

We explore the InSb-semiconductor lattice dynamics after excitation of high density electron-hole plasma with an ultrashort and intense laser pulse. By using time resolved x-ray diffraction, a sub-mÅ and sub-ps resolution was achieved. Thus, a strain of 4% was measured in a 3 nm thin surface layer 2 ps after excitation. The lattice strain was observed for the first 5 ps as exponentially decaying, changing rapidly by time and by depth. The observed phenomena can only be understood assuming nonlinear time dependent laser absorption where the absorption depth decreases by a factor of twenty compared to linear absorption.

2.
Rev Sci Instrum ; 87(4): 043106, 2016 04.
Artigo em Inglês | MEDLINE | ID: mdl-27131653

RESUMO

Single-photon spectroscopy of pulsed, high-intensity sources of hard X-rays - such as laser-generated plasmas - is often hampered by the pileup of several photons absorbed by the unsegmented, large-volume sensors routinely used for the detection of high-energy radiation. Detectors based on the Timepix chip, with a segmentation pitch of 55 µm and the possibility to be equipped with high-Z sensor chips, constitute an attractive alternative to commonly used passive solutions such as image plates. In this report, we present energy calibration and characterization measurements of such devices. The achievable energy resolution is comparable to that of scintillators for γ spectroscopy. Moreover, we also introduce a simple two-detector Compton polarimeter setup with a polarimeter quality of (98 ± 1)%. Finally, a proof-of-principle polarimetry experiment is discussed, where we studied the linear polarization of bremsstrahlung emitted by a laser-driven plasma and found an indication of the X-ray polarization direction depending on the polarization state of the incident laser pulse.

3.
Phys Rev E ; 93: 043201, 2016 04.
Artigo em Inglês | MEDLINE | ID: mdl-27176413

RESUMO

An analysis of an electron spectrometer used to characterize fast electrons generated by ultraintense (10^{20}Wcm^{-2}) laser interaction with a preformed plasma of scale length measured by shadowgraphy is presented. The effects of fringing magnetic fields on the electron spectral measurements and the accuracy of density scale-length measurements are evaluated. 2D EPOCH PIC code simulations are found to be in agreement with measurements of the electron energy spectra showing that laser filamentation in plasma preformed by a prepulse is important with longer plasma scale lengths (>8 µm).

4.
Phys Rev Lett ; 110(25): 254801, 2013 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-23829740

RESUMO

The polarization purity of 6.457- and 12.914-keV x rays has been improved to the level of 2.4×10(-10) and 5.7×10(-10). The polarizers are channel-cut silicon crystals using six 90° reflections. Their performance and possible applications are demonstrated in the measurement of the optical activity of a sucrose solution.

5.
Rev Sci Instrum ; 83(11): 113507, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23206062

RESUMO

We developed a detection scheme, capable of measuring X-ray line shape of tracer ions in µm thick layers at the rear side of a target foil irradiated by ultra intense laser pulses. We performed simulations of the effect of strong electric fields on the K-shell emission of silicon and developed a spectrometer dedicated to record this emission. The combination of a cylindrically bent crystal in von Hámos geometry and a CCD camera with its single photon counting capability allows for a high dynamic range of the instrument and background free spectra. This approach will be used in future experiments to study electric fields of the order of TV/m at high density plasmas close to solid density.

6.
Phys Rev Lett ; 105(8): 085001, 2010 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-20868103

RESUMO

Front and rear side x-ray emission from thin titanium foils irradiated by ultraintense laser pulses at intensities up to ≈5 × 10(19) W/cm2 was measured using a high-resolution imaging system. Significant differences in intensity, dimension, and spectrum between front and rear side emission intensity in the 3-12 keV photon energy range was found even for 5 µm thin Ti foils. Simulations and analysis of space-resolved spectra explain this behavior in terms of directional bremsstrahlung emission from fast electrons generated during the interaction process.

7.
Phys Rev E Stat Nonlin Soft Matter Phys ; 81(2 Pt 2): 026406, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20365664

RESUMO

We study warm dense matter formed by subpicosecond laser irradiation at several 10(19) W/cm(2) of thin Ti foils using x-ray spectroscopy with high spectral (E/DeltaE approximately 15,000) and one-dimensional spatial (Deltax=13.5 microm) resolutions. Ti Kalpha doublets modeled by line-shape calculations are compared with Abel-inverted single-pulse experimental spectra and provide radial distributions of the bulk-electron temperature and the absolute-photon number Kalpha yield in the target interiors. A core with approximately 40 eV extends homogeneously up to ten times the laser-focus size. The spatial distributions of the bulk-electron temperature and Kalpha yield are strongly correlated.

8.
Rev Sci Instrum ; 78(10): 103506, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17979418

RESUMO

Spectrally resolved two-dimensional imaging of ultrashort laser-produced plasmas is described, obtained by means of an advanced technique. The technique has been tested with microplasmas produced by ultrashort relativistic laser pulses. The technique is based on the use of a pinhole camera equipped with a charge coupled device detector operating in the single-photon regime. The spectral resolution is about 150 eV in the 4-10 keV range, and images in any selected photon energy range have a spatial resolution of 5 microm. The potential of the technique to study fast electron propagation in ultraintense laser interaction with multilayer targets is discussed and some preliminary results are shown.


Assuntos
Gases/análise , Gases/química , Aumento da Imagem/instrumentação , Interpretação de Imagem Assistida por Computador/instrumentação , Lasers , Processamento de Sinais Assistido por Computador/instrumentação , Espectrometria por Raios X/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Temperatura Alta , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Reprodutibilidade dos Testes , Semicondutores , Sensibilidade e Especificidade , Espectrometria por Raios X/métodos
9.
Rev Sci Instrum ; 78(8): 083301, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17764317

RESUMO

Particle pulses generated by laser-plasma interaction are characterized by ultrashort duration, high particle density, and sometimes a very strong accompanying electromagnetic pulse (EMP). Therefore, beam diagnostics different from those known from classical particle accelerators such as synchrotrons or linacs are required. Easy to use single-shot techniques are favored, which must be insensitive towards the EMP and associated stray light of all frequencies, taking into account the comparably low repetition rates and which, at the same time, allow for usage in very space-limited environments. Various measurement techniques are discussed here, and a space-saving method to determine several important properties of laser-generated electron bunches simultaneously is presented. The method is based on experimental results of electron-sensitive imaging plate stacks and combines these with Monte Carlo-type ray-tracing calculations, yielding a comprehensive picture of the properties of particle beams. The total charge, the energy spectrum, and the divergence can be derived simultaneously for a single bunch.


Assuntos
Algoritmos , Elétrons , Gases/química , Lasers , Modelos Químicos , Radiometria/instrumentação , Radiometria/métodos , Simulação por Computador , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Temperatura Alta , Doses de Radiação , Reprodutibilidade dos Testes , Espalhamento de Radiação , Sensibilidade e Especificidade
10.
Ophthalmic Res ; 21(3): 239-48, 1989.
Artigo em Inglês | MEDLINE | ID: mdl-2779977

RESUMO

In this paper, a method is presented to evaluate the true values of several optical parameters of the anterior eye segment. These are: the thicknesses of the cornea and lens, the depth of the anterior chamber and the anterior and posterior curvatures of the cornea and lens. First, a photo is taken of each patient's eye with a Topcon SL-45 Scheimpflug camera. There are two effects distorting the photo. As the film plane and the object plane are perpendicular to each other, the imaging scale is not constant over the photo, a phenomenon which is called the camera distortion. As the light passes through different refractive media on its way from the inner structures of the eye to the camera, the rays of light are refracted, which is called the refractive distortion of the eye. Following these distortions, the proportions on the photo do not correspond to those in the human eye. The intention of this paper is to calculate the true optical parameters of the anterior eye segment. The seeming optical parameters are taken from the photo and the path of light from a point in the film plane through the camera and the refracting surfaces into the eye is constructed by ray tracing. A set of representative points calculated according to ray tracing provides a basis to evaluate the true optical parameters. This work is done using a Basic program, that accepts the seeming parameters from the photo as input values and provides the true values as output. The adjectives seeming and true added to the optical parameters indicate a value correlating with a distorted photo and a value that was corrected by the theory. The two terms were chosen by mnemonic reasons, although another pair of adjectives such as distorted and corrected might have been of higher precision. For an average adult human eye the optical parameters from the photo were compared with the calculated ones. A phantom eye with well-known optical parameters was constructed and photos were taken from this eye to verify the calculations.


Assuntos
Segmento Anterior do Olho , Biometria/métodos , Córnea/análise , Humanos , Cristalino/análise , Fotografação , Estatística como Assunto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...