Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
1.
Sci Rep ; 14(1): 21961, 2024 09 20.
Artigo em Inglês | MEDLINE | ID: mdl-39304686

RESUMO

The rapid spread of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has triggered global difficulties for both individuals and economies, with new variants continuing to emerge. The Delta variant of SARS-CoV-2 remains most prevalent worldwide, and it affects the efficacy of coronavirus disease 2019 (COVID-19) vaccination. Expedited testing to detect the Delta variant of SARS-CoV-2 and monitor viral transmission is necessary. This study aimed to develop and evaluate a colorimetric reverse-transcription loop-mediated isothermal amplification (RT-LAMP) technique targeting the L452R mutation in the S gene for the specific detection of the Delta variant. In the test, positivity was indicated as a color change from purple to yellow. The assay's 95% limit of detection was 57 copies per reaction for the L452R (U1355G)-specific standard plasmid. Using 126 clinical samples, our assay displayed 100% specificity, 97.06% sensitivity, and 98.41% accuracy in identifying the Delta variant of SARS-CoV-2 compared to real-time RT-PCR. To our knowledge, this is the first colorimetric RT-LAMP assay that can differentiate the Delta variant from its generic SARS-CoV-2, enabling it as an approach for studying COVID-19 demography and facilitating proper effective control measure establishment to fight against the reemerging variants of SARS-CoV-2 in the future.


Assuntos
COVID-19 , Colorimetria , Mutação , Técnicas de Amplificação de Ácido Nucleico , SARS-CoV-2 , SARS-CoV-2/genética , Humanos , Técnicas de Amplificação de Ácido Nucleico/métodos , Colorimetria/métodos , COVID-19/virologia , COVID-19/diagnóstico , COVID-19/genética , Sensibilidade e Especificidade , Técnicas de Diagnóstico Molecular/métodos , Glicoproteína da Espícula de Coronavírus/genética , RNA Viral/genética , Teste de Ácido Nucleico para COVID-19/métodos
2.
Diagn Microbiol Infect Dis ; 110(2): 116446, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39096664

RESUMO

COVID-19 has afflicted millions of lives worldwide. Although there are many rapid methods to detect it based on colorimetric loop-mediated isothermal amplification, there remains room for improvement. This study aims to 1) integrate multiple primers into a singleplex assay to enhance the diagnostic sensitivity, and 2) utilize a high-throughput smartphone-operatable AI-driven color reading tool to enable a rapid result analysis. This setup can improve the sensitivity by 10-100 times and can analyze approximately 6700 samples per minute. The assay is simpler than RT-qPCR, with a turnaround time of less than 75 min. It can detect various types of SARS-CoV-2 by targeting 3 genes, increasing the likelihood that it will remain effective even if the virus undergoes mutations in any single target gene. In summary, it affords potential for adaptation to detection of new/re-emerging diseases with the visual readout for maximum assay simplicity and AI-operated mode for large-scale testing.


Assuntos
COVID-19 , Colorimetria , Técnicas de Diagnóstico Molecular , Técnicas de Amplificação de Ácido Nucleico , SARS-CoV-2 , Sensibilidade e Especificidade , Colorimetria/métodos , Humanos , COVID-19/diagnóstico , COVID-19/virologia , SARS-CoV-2/genética , SARS-CoV-2/isolamento & purificação , Técnicas de Amplificação de Ácido Nucleico/métodos , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Diagnóstico Molecular/normas , Primers do DNA/genética , Teste de Ácido Nucleico para COVID-19/métodos , Smartphone , Teste para COVID-19/métodos
3.
J Aquat Anim Health ; 36(3): 205-219, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38923038

RESUMO

OBJECTIVE: The World Organization for Animal Health still regulates the infectious hypodermal and hematopoietic necrosis virus (IHHNV) in shrimp. The existing disease identification approach is time consuming, necessitates expensive equipment, and requires specialized expertise, thereby limiting the accessibility of shrimp disease screening on farms. Loop-mediated isothermal amplification (LAMP) is recognized for its ability to detect inhibitory substances with high sensitivity and specificity. METHODS: We developed a real-time triplex LAMP assay that combines the simplicity of point-of-care testing with the accuracy of a turbidimeter. Using a set of three LAMP primers, our technology enables rapid DNA amplification in a single reaction within 45 min and with a low detection limit (10 copies/reaction). RESULT: We tested 192 shrimp samples from different sources and demonstrated the clinical utility of our method, achieving 100% specificity (95% confidence interval = 93.40-100.00%), 100% sensitivity (97.36-100.00%), and 100% accuracy (98.10-100.00%) in detecting IHHNV DNA, with a high Cohen's kappa value (1) compared to the standard quantitative polymerase chain reaction assay. CONCLUSION: The high technology readiness level of our method makes it a versatile platform for any real-time LAMP assay, and its low cost and simplicity make it well suited for fast deployment and use in shrimp farming.


Assuntos
Densovirinae , Técnicas de Amplificação de Ácido Nucleico , Penaeidae , Sensibilidade e Especificidade , Animais , Técnicas de Amplificação de Ácido Nucleico/métodos , Técnicas de Amplificação de Ácido Nucleico/veterinária , Penaeidae/virologia , Densovirinae/isolamento & purificação , Densovirinae/genética , Nefelometria e Turbidimetria/veterinária , Nefelometria e Turbidimetria/métodos , Técnicas de Diagnóstico Molecular
4.
PeerJ ; 12: e16422, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38188160

RESUMO

Background: Vibrio parahaemolyticus is the leading cause of bacterial seafood-borne gastroenteritis in humans worldwide. To ensure seafood safety and to minimize the occurrence of seafood-borne diseases, early detection of total V. parahaemolyticus (pathogenic and non-pathogenic strains) and pathogenic V. parahaemolyticus (tdh+ and/or trh1+ and/or trh2+) is required. This study further improved a loop-mediated isothermal amplification (LAMP) assay using xylenol orange (XO), a pH sensitive dye, to transform conventional LAMP into a one-step colorimetric assay giving visible results to the naked eye. LAMP-XO targeted rpoD for species specificity and tdh, trh1, and trh2 for pathogenic strains. Multiple hybrid inner primers (MHP) of LAMP primers for rpoD detection to complement the main primer set previously reported were designed by our group to maximize sensitivity and speed. Methods: Following the standard LAMP protocol, LAMP reaction temperature for rpoD, tdh, trh1, and trh2 detection was first determined using a turbidimeter. The acquired optimal temperature was subjected to optimize six parameters including dNTP mix, betaine, MgSO4, Bst 2.0 WarmStart DNA polymerase, reaction time and XO dye. The last parameter was done using a heat block. The color change of the LAMP-XO result from purple (negative) to yellow (positive) was monitored visually. The detection limits (DLs) of LAMP-XO using a 10-fold serial dilution of gDNA and spiked seafood samples were determined and compared with standard LAMP, PCR, and quantitative PCR (qPCR) assays. Subsequently, the LAMP-XO assay was validated with 102 raw seafood samples and the results were compared with PCR and qPCR assays. Results: Under optimal conditions (65 °C for 75 min), rpoD-LAMP-XO and tdh-LAMP-XO showed detection sensitivity at 102 copies of gDNA/reaction, or 10 folds greater than trh1-LAMP-XO and trh2-LAMP-XO. This level of sensitivity was similar to that of standard LAMP, comparable to that of the gold standard qPCR, and 10-100 times higher than that of PCR. In spiked samples, rpoD-LAMP-XO, tdh-LAMP-XO, and trh2-LAMP-XO could detect V. parahaemolyticus at 1 CFU/2.5 g spiked shrimp. Of 102 seafood samples, LAMP-XO was significantly more sensitive than PCR (P < 0.05) for tdh and trh2 detection and not significantly different from qPCR for all genes determined. The reliability of tdh-LAMP-XO and trh2-LAMP-XO to detect pathogenic V. parahaemolyticus was at 94.4% and 100%, respectively. Conclusions: To detect total and pathogenic V. parahaemolyticus, at least rpoD-LAMP-XO and trh2-LAMP-XO should be used, as both showed 100% sensitivity, specificity, and accuracy. With short turnaround time, ease, and reliability, LAMP-XO serves as a better alternative to PCR and qPCR for routine detection of V. parahaemolyticus in seafood. The concept of using a one-step LAMP-XO and MHP-LAMP to enhance efficiency of diagnostic performance of LAMP-based assays can be generally applied for detecting any gene of interest.


Assuntos
Gastroenterite , Vibrio parahaemolyticus , Humanos , Colorimetria , Vibrio parahaemolyticus/genética , Reprodutibilidade dos Testes
5.
Talanta ; 249: 123375, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-35738204

RESUMO

Colorimetric loop-mediated DNA isothermal amplification-based assays have gained momentum in the diagnosis of COVID-19 owing to their unmatched feasibility in low-resource settings. However, the vast majority of them are restricted to proprietary pH-sensitive dyes that limit downstream assay optimization or hinder efficient result interpretation. To address this problem, we developed a novel dual colorimetric RT-LAMP assay using in-house pH-dependent indicators to maximize the visual detection and assay simplicity, and further integrated it with the artificial intelligence (AI) operated tool (RT-LAMP-DETR) to enable a more precise and rapid result analysis in large scale testing. The dual assay leverages xylenol orange (XO) and a newly formulated lavender green (LG) dye for distinctive colorimetric readouts, which enhance the test accuracy when performed and analyzed simultaneously. Our RT-LAMP assay has a detection limit of 50 viral copies/reaction with the cycle threshold (Ct) value ≤ 39.7 ± 0.4 determined by the WHO-approved RT-qPCR assay. RT-LAMP-DETR exhibited a complete concordance with the results from naked-eye observation and RT-qPCR, achieving 100% sensitivity, specificity, and accuracy that altogether render it suitable for ultrasensitive point-of-care COVID-19 screening efforts. From the perspective of pandemic preparedness, our method offers a simpler, faster, and cheaper (∼$8/test) approach for COVID-19 testing and other emerging pathogens with respect to RT-qPCR.


Assuntos
COVID-19 , Inteligência Artificial , COVID-19/diagnóstico , Teste para COVID-19 , Colorimetria/métodos , DNA , Humanos , Técnicas de Amplificação de Ácido Nucleico/métodos , Sistemas Automatizados de Assistência Junto ao Leito , RNA , RNA Viral/genética , SARS-CoV-2/genética , Sensibilidade e Especificidade
6.
PLoS One ; 16(7): e0254029, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34197563

RESUMO

Development of a simple, rapid and specific assay for the simultaneous detection of Campylobacter spp. and Salmonella spp. based on duplex loop-mediated isothermal amplification (d-LAMP), combined with lateral-flow biosensor (LFB) is reported herein. LAMP amplicons of both pathogens were simultaneously amplified and specifically differentiated by LFB. The specificity of the d-LAMP-LFB was evaluated using a set of 68 target and 12 non-target strains, showing 100% inclusivity and exclusivity. The assay can simultaneously detect Campylobacter and Salmonella strains as low as 1 ng and 100 pg genomic DNA per reaction, respectively. The lowest inoculated detection limits for Campylobacter and Salmonella species in artificially contaminated chicken meat samples were 103 CFU and 1 CFU per 25 grams, respectively, after enrichment for 24 h. Furthermore, compared to culture-based methods using field chicken meat samples, the sensitivity, specificity and accuracy of d-LAMP- LFB were 95.6% (95% CI, 78.0%-99.8%), 71.4% (95% CI, 29.0%-96.3%) and 90.0% (95% CI, 73.4%-97.8%), respectively. The developed d-LAMP-LFB assay herein shows great potentials for the simultaneous detection of the Campylobacter and Salmonella spp. and poses a promising alternative approach for detection of both pathogens with applications in food products.


Assuntos
Campylobacter/isolamento & purificação , Galinhas/microbiologia , Técnicas de Diagnóstico Molecular , Técnicas de Amplificação de Ácido Nucleico , Salmonella/isolamento & purificação , Animais , Técnicas Biossensoriais/normas , Campylobacter/genética , Campylobacter/patogenicidade , Análise de Alimentos , Microbiologia de Alimentos , Humanos , Limite de Detecção , Salmonella/genética , Salmonella/patogenicidade
7.
J Fish Dis ; 44(10): 1595-1607, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34170523

RESUMO

Tilapia is one of the major aquaculture species with a global economic significance. Despite a high scale of production worldwide, mortality in many tilapia cultures has recently become a problem concerned with not only intensive farming but also the prevalence of infectious pathogens. Tilapia lake virus (TiLV) has emerged as a serious single-stranded RNA disease agent that thus far has continued to cause a number of incidences across the continents. Conventional PCR-based molecular detection techniques, despite having high sensitivity for TiLV, are not best suited for the onsite identification of infected fish mainly due to their requirement of laboratory resources and extended assay turnaround time. To address this practical limitation, we have developed a novel colorimetric assay based on reverse transcription-loop-mediated isothermal amplification (RT-LAMP) and gold nanoparticle (AuNP)-labelled oligonucleotide reporter probe targeting the viral genomic segment 9 that enables the assay to be completed within an hour. This technique has been shown to be compatible with a rapid nucleic extraction method that does not demand centrifugation steps or any benchtop laboratory equipment. When validated with field-acquired tilapia samples, our RT-LAMP-AuNP assay exhibited a near-perfect agreement with the semi-nested RT-PCR assay recommended by OIE with Cohen's κ coefficient of .869, yet requiring significantly less time to perform.


Assuntos
Aquicultura/métodos , Ciclídeos , Colorimetria/veterinária , Doenças dos Peixes/diagnóstico , Nanopartículas Metálicas/uso terapêutico , Técnicas de Diagnóstico Molecular/veterinária , Técnicas de Amplificação de Ácido Nucleico/veterinária , Infecções por Vírus de RNA/veterinária , Vírus de RNA/isolamento & purificação , Animais , Doenças dos Peixes/virologia , Ouro/uso terapêutico , Infecções por Vírus de RNA/diagnóstico , Infecções por Vírus de RNA/virologia , Transcrição Reversa , Sensibilidade e Especificidade
8.
Sensors (Basel) ; 21(9)2021 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-33946302

RESUMO

Electrowetting-on-dielectric (EWOD) is a microfluidic technology used for manipulating liquid droplets at microliter to nanoliter scale. EWOD has the ability to facilitate the accurate manipulation of liquid droplets, i.e., transporting, dispensing, splitting, and mixing. In this work, EWOD fabrication with suitable and affordable materials is proposed for creating EWOD lab-on-a-chip platforms. The EWOD platforms are applied for the diagnosis of early mortality syndrome (EMS) in shrimp by utilizing the colorimetric loop-mediated isothermal amplification method with pH-sensitive xylenol orange (LAMP-XO) diagnosis technique. The qualitative sensitivity is observed by comparing the limit of detection (LOD) while performing the LAMP-XO diagnosis test on the proposed lab-on-a-chip EWOD platform, alongside standard LAMP laboratory tests. The comparison results confirm the reliability of EMS diagnosis on the EWOD platform with qualitative sensitivity for detecting the EMS DNA plasmid concentration at 102 copies in a similar manner to the common LAMP diagnosis tests.


Assuntos
Eletroumectação , Técnicas Analíticas Microfluídicas , Colorimetria , Técnicas de Diagnóstico Molecular , Técnicas de Amplificação de Ácido Nucleico , Reprodutibilidade dos Testes
9.
PeerJ ; 9: e11082, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33777539

RESUMO

Being ubiquitous, fungi are common opportunistic pathogens to humans that can lead to invasive and life-threatening infections in immunocompromised individuals. Eukaryote-resembling cell membrane and filamentous branches make the fungal diagnosis difficult. This study therefore developed a ready-to-use ITS1 loop-mediated isothermal amplification combined with hydroxynaphthol blue (LAMP-HNB) for rapid, sensitive and specific colorimetric detection of universal fungi in all phyla. The ITS1 LAMP-HNB could identify every evolutionary phylum of fungi according to sequence analyses. We tested a total of 30 clinically relevant fungal isolates (representing three major human pathogenic phyla of fungi, namely Zygomycota, Ascomycota and Basidiomycota) and 21 non-fungal isolates, and the ITS1 LAMP-HNB properly identified all isolates, with a detection limit of as low as 4.6 ag (9.6 copies), which was identical to ITS1 and 18S rDNA PCR. The assays were also validated on the feasibility of point-of-care diagnostic with real food (dry peanuts, chili and garlics) and blood samples. Furthermore, the shelf life of our ready-to-use ITS1 LAMP activity (≥50%) was more than 40 days at 30 °C with 3-5% polyvinyl alcohol or glycerol additive. The results supported the ready-to-use ITS1 LAMP-HNB for simple detection of fungi contamination with high sensitivity in local and resource-constrained areas to prevent opportunistic fungal species infections.

10.
PLoS One ; 16(1): e0245144, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33411848

RESUMO

Clostridium perfringens is a key anaerobic pathogen causing food poisoning. Definitive detection by standard culture method is time-consuming and labor intensive. Current rapid commercial test kits are prohibitively expensive. It is thus necessary to develop rapid and cost-effective detection tool. Here, loop-mediated isothermal amplification (LAMP) in combination with a lateral-flow biosensor (LFB) was developed for visual inspection of C. perfringens-specific cpa gene. The specificity of the developed test was evaluated against 40 C. perfringens and 35 other bacterial strains, which showed no cross-reactivity, indicating 100% inclusivity and exclusivity. LAMP-LFB detection limit for artificially contaminated samples after enrichment for 16 h was 1-10 CFU/g sample, which was comparable to the commercial real-time PCR kit. The detection performance of LAMP-LFB was also compared to culture-based method using 95 food samples, which revealed the sensitivity (SE), specificity (SP) and Cohen's kappa coefficient (κ) of 88.0% (95% CI, 75.6%-95.4%), 95.5% (95% CI, 84.8%-99.4%) and 0.832 (95% CI, 0.721-0.943), respectively. Area under the receiver operating characteristic (ROC) curve was 0.918 (95% CI, 0.854-0.981), indicating LAMP-LFB as high relative accuracy test. In conclusion, LAMP-LFB assay is a low-cost qualitative method and easily available for routine detection of C. perfringens in food samples, which could serve as an alternative to commercial test kit.


Assuntos
Técnicas Biossensoriais , Clostridium perfringens/genética , Microbiologia de Alimentos , Técnicas de Diagnóstico Molecular , Técnicas de Amplificação de Ácido Nucleico , Limite de Detecção
11.
Sci Rep ; 10(1): 16976, 2020 10 12.
Artigo em Inglês | MEDLINE | ID: mdl-33046776

RESUMO

Mycobacterium tuberculosis (Mtb) is an insidious scourge that has afflicted millions of people worldwide. Although there are many rapid methods to detect it based on loop-mediated isothermal amplification (LAMP) and a lateral flow dipstick (LFD), this study made further improvements using a new set of primers to enhance LAMP performance and a novel DNA probe system to simplify detection and increase specificity. The new probe system eliminates the post-LAMP hybridization step typically required for LFD assays by allowing co-hybridization and amplification of target DNA in one reaction while preventing self-polymerization that could lead to false-positive results. The improved assay was named Probe-Triggered, One-Step, Simultaneous DNA Hybridization and LAMP Integrated with LFD (SH-LAMP-LFD). SH-LAMP-LFD was simpler to perform and more sensitive than previously reported LAMP-LFD and PCR methods by 100 and 1000 times, respectively. It could detect a single cell of Mtb. The absence of cross-reactivity with 23 non-TB bacteria, and accurate test results with all 104 blind clinical samples have highlighted its accuracy. Its robustness and portability make SH-LAMP-LFD suitable for users in both low and high resource settings.


Assuntos
DNA Bacteriano , Técnicas de Diagnóstico Molecular/métodos , Mycobacterium tuberculosis/genética , Mycobacterium tuberculosis/isolamento & purificação , Técnicas de Amplificação de Ácido Nucleico/métodos , Hibridização de Ácido Nucleico/métodos , Tuberculose/diagnóstico , Tuberculose/microbiologia , Sondas de DNA , Humanos , Reação em Cadeia da Polimerase/métodos , Sensibilidade e Especificidade
12.
J Pharm Biomed Anal ; 186: 113333, 2020 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-32402994

RESUMO

Tuberculosis (TB) is one of the most contagious and lethal infectious diseases that affects more than 10 million individuals worldwide. A lack of rapid TB diagnosis is partly responsible for its alarming spread and prevalence in many regions. To address this problem, we report a novel integrated point-of-care platform to detect a TB-causative bacterium, Mycobacterium tuberculosis (Mtb). This leverages loop-mediated isothermal amplification (LAMP) for Mtb-DNA amplification and the screen-printed graphene electrode (SPGE) for label-free electrochemical analysis of DNA amplicons. When implemented on a portable potentiostat device developed in-house, the system (LAMP-EC) offers a rapid end-point qualitative analysis of specific DNA amplicons that will be displayed as a discrete positive/negative readout on the LCD screen. Under optimized conditions, LAMP-EC showed a comparable detection limit to the previously developed LAMP assay with a lateral flow readout at 1 pg total DNA or 40 Mtb genome equivalents. This highly specific technique detected the presence of TB in all 104 blinded sputum samples with a 100% accuracy. Our technique can also easily be clinically adopted due to its affordability (∼USD2.5/test), rapidity (<65 min turnaround time) and feasibility (lack of advanced instrumental requirement). This serves as a practical incentive, appealing to users in both high- and low-resource settings across the TB endemic regions and economic backgrounds.


Assuntos
Técnicas Eletroquímicas/métodos , Mycobacterium tuberculosis/isolamento & purificação , Sistemas Automatizados de Assistência Junto ao Leito , Tuberculose/diagnóstico , DNA Bacteriano/análise , Eletrodos , Grafite/química , Técnicas de Diagnóstico Molecular , Técnicas de Amplificação de Ácido Nucleico , Sensibilidade e Especificidade , Tuberculose/microbiologia
13.
Biosens Bioelectron ; 132: 271-278, 2019 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-30878727

RESUMO

Vibrio parahaemolyticus is one of the most important foodborne pathogens that cause various life-threatening diseases in human and animals. Here, we present a rapid detection platform for V. parahaemolyticus by combining loop-mediated isothermal amplification (LAMP) and disposable electrochemical sensors based on screen-printed graphene electrodes (SPGEs). The LAMP reactions using primers targeting V. parahaemolyticus toxR gene were optimized at an isothermal temperature of 65 °C, providing specific detection of V. parahaemolyticus within 45 min at the detection limit of 0.3 CFU per 25 g of raw seafood. The LAMP amplicons can be effectively detected using unmodified SPGEs, redox active molecules namely Hoechst-33258 and a portable potentiostat. Therefore, the proposed system is particularly suitable as a point-of-care device for on-site detection of foodborne pathogens.


Assuntos
Técnicas Biossensoriais/instrumentação , Técnicas Eletroquímicas/instrumentação , Análise de Alimentos/instrumentação , Técnicas de Amplificação de Ácido Nucleico/instrumentação , Alimentos Marinhos/microbiologia , Vibrioses/microbiologia , Vibrio parahaemolyticus/isolamento & purificação , DNA Bacteriano/análise , DNA Bacteriano/genética , Eletrodos , Desenho de Equipamento , Grafite/química , Humanos , Limite de Detecção , Sistemas Automatizados de Assistência Junto ao Leito , Vibrio parahaemolyticus/genética
15.
Food Sci Biotechnol ; 27(3): 867-875, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30263813

RESUMO

Multiplex PCR (m-PCR) has the potential for more rapid detection of pathogens compared to simple PCR through the simultaneous amplification of multiple gene targets using several sets of specific primers. Here, we developed an m-PCR assay which combined dry reagent mixtures for ready-to-use simultaneous detection of Salmonella spp., Bacillus cereus, and Staphylococcus aureus. The assay did not show cross-reactivity with several common bacterial pathogens and the detection limit was 103 CFU/mL for mixed genomic DNA in pure culture. Lyophilized m-PCR reagents are stable for 2 months stored at 4 °C and for 1 month stored at 25 °C. Detection sensitivities of both dry and fresh mixes were able to simultaneously detect 10 CFU/mL of each pathogen in artificially inoculated samples after enrichment for 6 and 12 h. Results demonstrated that this method is both sensitive and specific and can be used for rapid detection and differentiation of foodborne diseases.

16.
Methods Mol Biol ; 1572: 431-443, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28299704

RESUMO

Loop-mediated isothermal amplification (LAMP) has been used to detect several pathogens including malaria parasites from field and clinical samples. In this protocol, the malaria LAMP technology is developed to differentiate between Plasmodium falciparum (Pf) and Plasmodium vivax (Pv) species by targeting the dihydrofolate reductase thymidylate synthase (dhfr-ts) gene, a known target for the antifolate class of drugs such as Pyrimethamine. LAMP primer sets are designed and validated for species specific amplification. Additionally, specific probes help improve detection and visualization of the products when combined with lateral flow dipstick-based (LFD) detection. The protocols are further simplified to eliminate tedious sample preparation steps, such that crude lysis prepared simply by diluting few microliter (µL) of blood sample with distilled water is sufficient. The LAMP-LFD malaria dhfr-ts protocols are sensitive and can detect as little as 1 picogram (pg) of PfDNA and 1 nanogram (ng) of PvDNA, or a few microliters of crude lysate from infected blood samples (Yongkiettrakul et al., Parasitol Int 63: 777-784, 2014). These simplified steps not only reduce cost but also increase the potential for large application in the fields and clinical settings.


Assuntos
Técnicas de Amplificação de Ácido Nucleico/métodos , Plasmodium falciparum/genética , Plasmodium vivax/genética , Primers do DNA , DNA de Protozoário , Genes de Protozoários , Humanos , Malária/diagnóstico
17.
Mol Med Rep ; 15(5): 3203-3209, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28339040

RESUMO

Cervical cancer is the third highest cause of death in developing countries and most commonly results from high­risk human papillomavirus (HR­HPV) infection. Among HR­HPV genotypes, HPV16 and HPV18 are the most prevalent in cervical cancers. Therefore, the present study aimed to develop a detection assay for HPV16 and HPV18 infection using loop­mediated isothermal amplification (LAMP) with lateral flow dipstick (LFD) tests. This assay is a simplified, user­friendly method for the visual detection of HPV genotypes. DNA was extracted from clinical tissue samples, and HPV genotyping was performed using nested polymerase chain reaction (PCR). The clinical samples were demonstrated to include 44 HPV16­positive, 18 HPV18­positive and 80 HPV­negative samples. All DNA samples were also used as templates for a LAMP reaction (30 min at 65˚C), and subsequently, a fluorescein isothiocyanate­labelled probe was hybridized with the reaction product. Finally, the LFD test was performed. The sensitivity of the LAMP­LFD test was higher than LAMP­turbidity, exhibiting up to 100­fold higher sensitivity for HPV16 and 10­fold higher sensitivity for HPV18. All HPV16 and HPV18­positive samples generated positive results in both assays; however, 22 samples detected as HPV­negative by LAMP­turbidity exhibited positive results by LAMP­LFD test (22 of 80 samples). Therefore, these samples were further examined using quantitative (q)PCR. The results demonstrated that 20 out of the 22 samples designated positive by LAMP­LFD, but negative by LAMP turbidity, gave a positive result with qPCR, while the remaining 2 samples were negative by qPCR. The present results suggested that LAMP­LFD provided higher sensitivity than LAMP­turbidity and nested PCR. Thus, the LAMP­LFD test developed in the present study might be useful for the detection of HPV16 and HPV18 in local hospitals.


Assuntos
DNA Viral/metabolismo , Papillomavirus Humano 16/genética , Papillomavirus Humano 18/genética , Técnicas de Amplificação de Ácido Nucleico/métodos , Anticorpos/química , Anticorpos/imunologia , Sondas de DNA/química , Sondas de DNA/metabolismo , DNA Viral/isolamento & purificação , Feminino , Genótipo , Ouro/química , Papillomavirus Humano 16/isolamento & purificação , Papillomavirus Humano 18/isolamento & purificação , Humanos , Imunoensaio , Kit de Reagentes para Diagnóstico , Reação em Cadeia da Polimerase em Tempo Real , Neoplasias do Colo do Útero/diagnóstico , Neoplasias do Colo do Útero/virologia
18.
Parasitol Int ; 66(1): 964-971, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27816495

RESUMO

The significant strides made in reducing global malaria burden over the past decades are being threatened by the emergence of multi-drug resistant malaria. Mechanisms of resistance to several classes of antimalarial drugs have been linked to key mutations in the Plasmodium falciparum genes. Pyrimethamine targets the dihydrofolate reductase of the bifunctional dihydrofolate reductase thymidylate synthase (DHFR-TS), and specific point mutations in the dhfr-ts gene have been assigned to resistant phenotypes. Several molecular methods are available to detect the mutant genotypes including DNA sequencing and PCR-based methods. In this study, we report the development of PfSNP-LAMP to detect nucleotide polymorphism in the dhfr gene associated with N51I mutation and antifolate resistance. The PfSNP-LAMP method was validated with genomic DNA samples and parasite lysates prepared from sensitive and pyrimethamine resistant strains of P. falciparum.


Assuntos
Mutação , Técnicas de Amplificação de Ácido Nucleico , Plasmodium falciparum/genética , Polimorfismo de Nucleotídeo Único , Tetra-Hidrofolato Desidrogenase/genética , Primers do DNA , DNA de Protozoário/genética , Resistência a Medicamentos/genética , Ácido Fólico , Genoma de Protozoário , Genótipo , Malária Falciparum/diagnóstico , Plasmodium falciparum/efeitos dos fármacos , Pirimetamina/farmacologia , Análise de Sequência de DNA , Manejo de Espécimes , Timidilato Sintase/genética
19.
J Virol Methods ; 234: 90-5, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27086727

RESUMO

High-risk human papillomavirus (HR-HPV) causes cervical cancer. HPV16 and HPV18 are the most prevalent strains of the virus reported in women worldwide. Loop-mediated isothermal amplification (LAMP) is an alternative method for DNA detection under isothermal conditions. However, it results in a turbid amplified product which is not easily detected by the naked eye. This study aimed to develop an improved technique by using gold nanoparticles (AuNPs) attached to a single-stranded DNA probe for the detection of HPV16 and HPV18. Detection of the LAMP product by AuNP color change was compared with detection by visual turbidity. The optimal conditions for this new LAMP-AuNP assay were an incubation time of 20min and a temperature of 65°C. After LAMP amplification was complete, its products were hybridized with the AuNP probe for 5min and then detected by the addition of magnesium salt. The color changed from red to blue as a result of aggregation of the AuNP probe under high ionic strength conditions produced by the addition of the salt. The sensitivity of the LAMP-AuNP assay was greater than the LAMP turbidity assay by up to 10-fold for both HPV genotypes. The LAMP-AuNP assay showed higher sensitivity and ease of visualization than did the LAMP turbidity for the detection of HPV16 and HPV18. Additionally, AuNP-HPV16 and AuNP-HPV18 probes were stable for over 1year. The combination of LAMP and the AuNP-probe colorimetric assay offers a simple, rapid and highly sensitive alternative diagnostic tool for the detection of HPV16 and HPV18 in district hospitals or field studies.


Assuntos
Colorimetria , Papillomavirus Humano 16/isolamento & purificação , Papillomavirus Humano 18/isolamento & purificação , Nanopartículas/química , Técnicas de Amplificação de Ácido Nucleico/métodos , Hibridização de Ácido Nucleico/métodos , DNA Complementar/química , Feminino , Genótipo , Ouro , Papillomavirus Humano 16/genética , Papillomavirus Humano 18/genética , Humanos , Infecções por Papillomavirus/diagnóstico , Infecções por Papillomavirus/virologia , Sensibilidade e Especificidade , Temperatura , Neoplasias do Colo do Útero/diagnóstico , Neoplasias do Colo do Útero/virologia
20.
PLoS One ; 11(3): e0151769, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27003504

RESUMO

Acute hepatopancreatic necrosis disease (AHPND) is a component cause of early mortality syndrome (EMS) of shrimp. In 2013, the causative agent was found to be unique isolates of Vibrio parahaemolyticus (VPAHPND) that contained a 69 kbp plasmid (pAP1) carrying binary Pir-like toxin genes PirvpA and PirvpB. In Thailand, AHPND was first recognized in 2012, prior to knowledge of the causative agent, and it subsequently led to a precipitous drop in shrimp production. After VPAHPND was characterized, a major focus of the AHPND control strategy was to monitor broodstock shrimp and post larvae for freedom from VPAHPND by nucleic acid amplification methods, most of which required use of expensive and sophisticated equipment not readily available in a shrimp farm setting. Here, we describe a simpler but equally sensitive approach for detection of VPAHPND based on loop-mediated isothermal amplification (LAMP) combined with unaided visual reading of positive amplification products using a DNA-functionalized, ssDNA-labled nanogold probe (AuNP). The target for the special set of six LAMP primers used was the VPAHPND PirvpA gene. The LAMP reaction was carried out at 65°C for 45 min followed by addition of the red AuNP solution and further incubation at 65°C for 5 min, allowing any PirvpA gene amplicons present to hybridize with the probe. Hybridization protected the AuNP against aggregation, so that the solution color remained red upon subsequent salt addition (positive test result) while unprotected AuNP aggregated and underwent a color change from red to blue and eventually precipitated (negative result). The total assay time was approximately 50 min. The detection limit (100 CFU) was comparable to that of other commonly-used methods for nested PCR detection of VPAHPND and 100-times more sensitive than 1-step PCR detection methods (104 CFU) that used amplicon detection by electrophoresis or spectrophotometry. There was no cross reaction with DNA templates derived from non-AHPND bacteria commonly found in shrimp ponds (including other Vibrio species). The new method significantly reduced the time, difficulty and cost for molecular detection of VPAHPND in shrimp hatchery and farm settings.


Assuntos
Nanopartículas Metálicas/química , Técnicas de Amplificação de Ácido Nucleico/métodos , Hibridização de Ácido Nucleico/métodos , Penaeidae/microbiologia , Vibrio parahaemolyticus/genética , Animais , Bacillus subtilis/genética , Primers do DNA/genética , Ouro/química , Limite de Detecção , Proteínas Associadas a Pancreatite , Reação em Cadeia da Polimerase/métodos , Vibrio parahaemolyticus/isolamento & purificação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA