Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 62
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38965878

RESUMO

BACKGROUND: Success of atypical atrial flutter (AAFL) ablation has historically been limited by difficulty mapping the complex re-entrant circuits involved. While high-density (HD) mapping has become commonplace in clinical practice, there are limited data on outcomes of HD versus non-HD mapping for AAFL ablation. OBJECTIVE: To compare clinical outcomes and healthcare utilization using HD mapping versus non-HD mapping for AAFL ablation. METHODS: Retrospective analysis of all AAFL procedures between 2005 and 2022 at an academic medical center was conducted. Procedures utilizing a 16-electrode HD Grid catheter and Precision mapping system were compared to procedures using prior generation 10-20 electrode spiral catheters and the Velocity system (Abbott, IL). Cox regression models and Poisson regression models were utilized to examine procedural and healthcare utilization outcomes. Models were adjusted for left ventricular ejection fraction, CHA2DS2-VASc, and history of prior ablation. RESULTS: There were 108 patients (62% HD mapping) included in the analysis. Baseline clinical characteristics were similar between groups. Use of HD mapping was associated with a higher rate of AAFL circuit delineation (92.5% vs. 76%; p = .014) and a greater adjusted procedure success rate, defined as non-inducibility at procedure end, (aRR (95% CI) 1.26 (1.02-1.55) p = .035) than non-HD mapping. HD mapping was also associated with a lower rate of ED visits (aIRR (95% CI) 0.32 (0.14-0.71); p = .007) and hospitalizations (aIRR (95% CI) 0.32 (0.14-0.68); p = .004) for AF/AFL/HF through 1 year. While there was a lower rate of recurrent AFL through 1 year among HD mapping cases (aHR (95% CI) 0.60 (0.31-1.16) p = .13), statistical significance was not met likely due to the low sample size and higher rate of ambulatory rhythm monitoring in the HD group (61% vs. 39%, p = .025). CONCLUSION: Compared to non-HD mapping, AAFL ablation with HD mapping is associated with improvements in the ability to define the AAFL circuit, greater procedural success, and a reduction in the number of ED visits and hospitalization for AF/AFL/HF.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38761294

RESUMO

BACKGROUND: The use of intravenous (IV) sotalol loading following recent U.S. Food and Drug Administration (FDA) approval of a 1-day loading protocol has reduced the obligatory 3-day hospital stay for sotalol initiation when given orally. Several studies have recently demonstrated the safety and feasibility of IV loading for patients with atrial arrhythmias. However, there is a paucity of data on the feasibility and safety of IV sotalol loading for patients with ventricular arrhythmias. This study aims to assess the safety, feasibility, and length of stay (LOS) outcomes of IV sotalol loading for the prevention of ventricular arrhythmias. METHODS: A retrospective analysis was performed of all patients undergoing IV sotalol loading and oral sotalol initiation for ventricular arrhythmias, or IV sotalol loading for atrial arrhythmias between August 2021 and December 2023 at Northwestern University. Baseline characteristics, success of sotalol initiation/loading, changes in heart rate (HR) and QT/QTc, safety, and LOS were compared between patients undergoing sotalol loading/initiation for ventricular arrhythmias (IV vs. PO) and between patients undergoing IV sotalol loading for ventricular arrhythmias vs. for atrial arrhythmias. RESULTS: A total of 28 patients underwent sotalol loading/initiation for ventricular arrhythmias (N = 15 IV and N = 13 PO) and 41 patients underwent IV sotalol loading for atrial arrhythmias. Baseline characteristics of congestive heart failure history and left ventricular ejection fraction were worse in the ventricular arrhythmias group. There was no significant difference in the successful completion of IV sotalol loading for ventricular arrhythmias compared to oral sotalol initiation for ventricular arrhythmias or IV sotalol loading for atrial arrhythmias (86.7% vs. 92.3% vs. 90.2%, p = 0.88). There was a significant increase in ΔQTc following IV sotalol infusion for ventricular arrhythmias compared to following PO sotalol initiation for ventricular arrhythmias (46.4 ± 29.2 ms vs. 8.9 ± 32.6 ms, p = 0.004) and following IV sotalol infusion for atrial arrhythmias (46.4 ± 29.2 ms vs. 24.0 ± 25.1 ms, p = 0.018). ΔHR following IV sotalol infusion for ventricular arrhythmias was similar to ΔHR following PO sotalol initiation for ventricular arrhythmias and ΔHR following IV sotalol infusion for atrial arrhythmias (- 7.5 ± 8.7 bpm vs. - 8.5 ± 13.9 bpm vs. - 8.3 ± 13.2 bpm, p = 0.87). There were no significant differences in discontinuation for QTc prolongation (6.7% vs. 1.7% vs. 2.4%, p = 0.64) and bradycardia (13.3% vs. 7.7% vs. 9.8%, p = 0.88) between IV sotalol loading for ventricular arrhythmias, PO sotalol initiation for ventricular arrhythmias, and IV sotalol loading for atrial arrhythmias. There were no instances of hypotension, life-threatening ventricular arrhythmias, heart failure, or death. Length of stay was significantly shorter for IV sotalol loading compared to PO sotalol initiation for ventricular arrhythmias (1.1 ± 0.36 days vs. 4.2 ± 1.0 days, p < 0.0001). CONCLUSION: IV sotalol loading appears feasible and safe for use in ventricular arrhythmias and results in a decreased length of stay. Despite increased comorbidities and greater increase in QTc interval following IV sotalol infusion in the ventricular arrhythmias group, there were no significant differences in successful completion of loading or adverse outcomes when compared to PO sotalol initiation for ventricular arrhythmias and IV loading for atrial arrhythmias.

4.
J Cardiovasc Electrophysiol ; 33(12): 2560-2566, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36317453

RESUMO

INTRODUCTION: Esophageal thermal injury (ETI) is a well-recognized complication of atrial fibrillation (AF) ablation. Previous studies have demonstrated that direct esophageal cooling reduces ETI during radiofrequency AF ablation. The purpose of this study was to evaluate the use of an esophageal warming device to prevent ETI during cryoballoon ablation (CBA) for AF. METHODS: This prospective, double-blinded study enrolled 42 patients with symptomatic AF undergoing CBA. Patients were randomized to the treatment group with esophageal warming (42°C) using recirculated water through a multilumen, silicone tube inserted into the esophagus (EnsoETM®; Attune Medical) (WRM) or the control group with a luminal single-electrode esophageal temperature monitoring probe (LET). Patients underwent upper endoscopy esophagogastroduodenoscopy (EGD) the following day. ETI was classified into four grades. RESULTS: Baseline patient characteristics were similar between groups. Procedural characteristics including number of freezes, total freeze time, early freeze terminations, coldest balloon temperature, procedure duration, posterior wall ablation, and proton pump inhibitor and transesophageal echocardiogram use before procedure were not different between groups. The EGD was completed in 40/42 patients. There was significantly more ETI in the WRM group compared to the LET group (n = 8 [38%] vs. n = 1 [5%], p = 0.02). All ETI lesions were grade 1 (erythema) or 2 (superficial ulceration). Total freeze time in the left inferior pulmonary vein was predictive of ETI (360 vs. 300 s, p = 0.03). CONCLUSION: Use of a luminal heat exchange tube for esophageal warming during CBA for AF was paradoxically associated with a higher risk of ETI.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Estudos Prospectivos , Temperatura , Ablação por Cateter/métodos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Criocirurgia/efeitos adversos
5.
PLoS One ; 17(1): e0262706, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35061809

RESUMO

BACKGROUND: Heart failure (HF) and chronic kidney disease (CKD) frequently coexist, and the combination is linked to poor outcomes, but limited data exist to guide optimal management. We evaluated the outcome of dialysis therapy in older patients with HF and advanced CKD. METHODS: We examined adults aged ≥70 years with HF and eGFR ≤20 ml/min/1.73 m2 between 2008-2012 and no prior renal replacement therapy, cancer, cirrhosis or organ transplant. We identified patients who initiated chronic dialysis through 2013 and matched patients who did not initiate dialysis on age, gender, diabetes status, being alive on dialysis initiation date, and a high-dimensional propensity score for starting dialysis. Deaths were identified through 2013. We used Cox regression to evaluate the association of chronic dialysis and all-cause death. RESULTS: Among 348 adults with HF and advanced CKD who initiated dialysis and 947 matched patients who did not start dialysis, mean age was 80±5 years, 51% were women and 33% were Black. The crude rate of death was high overall but lower in those initiating vs. not initiating chronic dialysis (26.1 vs. 32.1 per 100 person-years, respectively, P = 0.02). In multivariable analysis, dialysis was associated with a 33% (95% Confidence Interval:17-46%) lower adjusted rate of death compared with not initiating dialysis. CONCLUSIONS: Among older adults with HF and advanced CKD, dialysis initiation was associated with lower mortality, but absolute rates of death were very high in both groups. Randomized trials should evaluate net outcomes of dialysis vs. conservative management on length and quality of life in this high-risk population.


Assuntos
Insuficiência Cardíaca/complicações , Diálise Renal , Insuficiência Renal Crônica/complicações , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , California , Feminino , Insuficiência Cardíaca/mortalidade , Humanos , Masculino , Pontuação de Propensão , Diálise Renal/mortalidade , Insuficiência Renal Crônica/mortalidade , Insuficiência Renal Crônica/terapia , Estudos Retrospectivos , Fatores de Risco , Fatores Sexuais
6.
Eur J Intern Med ; 81: 89-90, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32980218

RESUMO

Flecainide pill-in-the-pocket therapy is a pharmacologic treatment option for patients with infrequent episodes of symptomatic atrial fibrillation. We report a case of wide complex tachycardia due to atrial flutter with 1:1 atrioventricular conduction in a patient who took pill-in-the-pocket flecainide without concomitant atrioventricular nodalblockade.


Assuntos
Fibrilação Atrial , Flutter Atrial , Antiarrítmicos/efeitos adversos , Fibrilação Atrial/tratamento farmacológico , Flutter Atrial/tratamento farmacológico , Eletrocardiografia , Flecainida/efeitos adversos , Humanos , Taquicardia
7.
J Cardiovasc Electrophysiol ; 31(7): 1579-1584, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32400079

RESUMO

INTRODUCTION: Moderate sedation (MS) during cryoballoon ablation (CBA) avoids risks of general anesthesia (GA) and improves electrophysiology (EP) lab throughput. However, one barrier to the use of MS is the potential for patient discomfort. The objective of this study was to compare patient-reported outcome measures following CBA for paroxysmal atrial fibrillation (pAF) under MS and GA. METHODS AND RESULTS: Consecutive patients undergoing a first CBA for pAF under GA or MS were prospectively enrolled. The sedation method was assigned based on patient and provider preference, and perceived airway risk. The primary outcomes were quality of recovery (measured using a validated 40 question survey; QoR-40) and likelihood to recommend (LTR) the procedure and sedation method (measured by Likert scale). Secondary outcomes were acute pulmonary vein (PV) isolation rate, procedure, fluoroscopy and ablation times, and complication rates. Forty-seven GA and 53 MS patients were included. The mean age was 64.9 ± 9.4 years and mean CHA2 DS2 -VASc score was 2.0 ± 1.4. QoR-40 scores were 184.6 ± 16.4 for GA and 187.6 ± 10.2 for MS (P = .28). LTR responses were similar between groups. Mean procedure times were 148.2 ± 56.0 minutes for GA and 129.4 ± 31.4 minutes for MS (P = .038). Fluoroscopy and ablation times were similar between groups. A total of 100% (409/409) of PVs were acutely isolated. One hemopericardium occurred in the MS group requiring pericardiocentesis. CONCLUSION: MS for CBA offers an alternative to GA that is safe and well-tolerated by patients with comparable success rates and improved EP lab throughput.


Assuntos
Anestesia Geral , Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Medidas de Resultados Relatados pelo Paciente , Veias Pulmonares , Idoso , Anestesia Geral/efeitos adversos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Sedação Consciente/efeitos adversos , Criocirurgia/efeitos adversos , Humanos , Pessoa de Meia-Idade , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Resultado do Tratamento
8.
JACC Case Rep ; 2(4): 611-614, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32432226

RESUMO

Vasospastic angina is an uncommon cause of cardiac arrest. We describe a patient who presented with sudden cardiac arrest due to severe coronary vasospasm. Telemetry during the event revealed ventricular arrhythmias and asystole followed by spontaneous self-conversion back to normal sinus rhythm. The patient underwent implantable cardioverter-defibrillator therapy. (Level of Difficulty: Beginner.).

9.
Int J Mol Sci ; 20(11)2019 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-31181796

RESUMO

Different phenotypes of normal cells might influence genetic profiles, epigenetic profiles, and tumorigenicities of their transformed derivatives. In this study, we investigate whether the whole mitochondrial genome of immortalized cells can be attributed to the different phenotypes (stem vs. non-stem) of their normal epithelial cell originators. To accurately determine mutations, we employed Duplex Sequencing, which exhibits the lowest error rates among currently-available DNA sequencing methods. Our results indicate that the vast majority of the observed mutations of the whole mitochondrial DNA occur at low-frequency (rare mutations). The most prevalent rare mutation types are C→T/G→A and A→G/T→C transitions. Frequencies and spectra of homoplasmic point mutations are virtually identical between stem cell-derived immortalized (SV1) cells and non-stem cell-derived immortalized (SV22) cells, verifying that both cell types were derived from the same woman. However, frequencies of rare point mutations are significantly lower in SV1 cells (5.79 × 10-5) than in SV22 cells (1.16 × 10-4). The significantly lower frequencies of rare mutations are aligned with a finding of longer average distances to adjacent mutations in SV1 cells than in SV22 cells. Additionally, the predicted pathogenicity for rare mutations in the mitochondrial tRNA genes tends to be lower (by 2.5-fold) in SV1 cells than in SV22 cells. While four known/confirmed pathogenic mt-tRNA mutations (m.5650 G>A, m.5521 G>A, m.5690 A>G, m.1630 A>G) were identified in SV22 cells, no such mutations were observed in SV1 cells. Our findings suggest that the immortalization of normal cells with stem cell features leads to decreased mitochondrial mutagenesis, particularly in RNA gene regions. The mutation spectra and mutations specific to stem cell-derived immortalized cells (vs. non-stem cell derived) have implications in characterizing the heterogeneity of tumors and understanding the role of mitochondrial mutations in the immortalization and transformation of human cells.


Assuntos
Neoplasias da Mama/genética , Células Epiteliais/metabolismo , Genoma Mitocondrial , Taxa de Mutação , Células-Tronco Adultas/metabolismo , Mama/citologia , Linhagem Celular Tumoral , Feminino , Humanos , Mutação Puntual , RNA de Transferência/genética
14.
JMM Case Rep ; 5(5): e005145, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29896405

RESUMO

Introduction: Although the current Zika virus (ZIKV) epidemic is a major public health concern, most reports have focused on congenital ZIKV syndrome, its most devastating manifestation. Severe ocular complications associated with ZIKV infections and possible pathogenetic factors are rarely described. Here, we describe three Venezuelan patients who developed severe ocular manifestations following ZIKV infections. We also analyse their serological response to ZIKV and dengue virus (DENV). Case presentation: One adult with bilateral optic neuritis, a child of 4 years of age with retrobulbar neuritis [corrected]. and a newborn with bilateral congenital glaucoma had a recent history of an acute exanthematous infection consistent with ZIKV infection. The results of ELISA tests indicated that all patients were seropositive for ZIKV and four DENV serotypes. Conclusion: Patients with ZIKV infection can develop severe ocular complications. Anti-DENV antibodies from previous infections could play a role in the pathogenesis of these complications. Well-designed epidemiological studies are urgently needed to measure the risk of ZIKV ocular complications and confirm whether they are associated with the presence of anti-flaviviral antibodies.

16.
J Atr Fibrillation ; 9(5): 1510, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29250268

RESUMO

BACKGROUND: Adenosine can unmask dormant conduction during pulmonary vein isolation (PVI) for atrial fibrillation (AF). Studies of adenosine use in radiofrequency PVI show high reconnection rates and conflicting results for long-term success, however there is limited data with cryoballoon ablation (CBA). METHODS: A prospectively maintained database of patients undergoing first CBA at a single institution was analyzed. Adenosine use was at the discretion of the primary operator. Additional freezes were delivered for reconnected veins until dormant conduction was eliminated. The primary endpoint, time to AF recurrence defined as any episode < 30 seconds after a 3-month blanking period, was assessed by Kaplan-Meier analysis. RESULTS: From 2011 to 2015, 406 patients underwent CBA, 361 of whom had > 3 months follow-up. The mean age was 61.7 years, 69% were male, and the prevalence of paroxysmal AF was 79% with no significant difference between those that did and did not receive adenosine (77% vs 86%, respectively, p = 0.23). Adenosine testing was performed in 78 patients (21.6%) with a mean dose of 10.6 mg/vein. Of the 306 veins evaluated, 17 (6%) demonstrated dormant conduction. Over a median 14.4 months follow-up, there was no significant difference in freedom from AF with adenosine use (p= 0.86). CONCLUSIONS: Dormant conduction with adenosine is uncommon following CBA and its use does not improve long-term success rates.

18.
Trends Cardiovasc Med ; 27(4): 260-268, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28108086

RESUMO

For years, conventional wisdom has held that patients with asymptomatic ventricular pre-excitation (asymptomatic WPW or WPW pattern) were at low risk for adverse outcomes. This assumption has been challenged more recently in a number of observational/natural history studies as well as in prospective trials in which patients were more aggressively studied via invasive electrophysiology study (EPS) and more aggressively treated, in some cases, with pre-emptive catheter ablation, despite the lack of symptoms. In sum, the data do not definitively support one approach (early, up-stream EPS and/or ablation) vs. the other (watchful waiting with close monitoring). The most recent pediatric and adult guidelines reflect this ambiguity with a broad spectrum of approaches endorsed.


Assuntos
Sistema de Condução Cardíaco/fisiopatologia , Síndrome de Wolff-Parkinson-White/etiologia , Potenciais de Ação , Adolescente , Adulto , Algoritmos , Doenças Assintomáticas , Ablação por Cateter , Criança , Procedimentos Clínicos , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Sistema de Condução Cardíaco/cirurgia , Frequência Cardíaca , Humanos , Pessoa de Meia-Idade , Guias de Prática Clínica como Assunto , Valor Preditivo dos Testes , Prognóstico , Medição de Risco , Fatores de Risco , Fatores de Tempo , Conduta Expectante , Síndrome de Wolff-Parkinson-White/diagnóstico , Síndrome de Wolff-Parkinson-White/fisiopatologia , Síndrome de Wolff-Parkinson-White/terapia , Adulto Jovem
20.
Pacing Clin Electrophysiol ; 39(12): 1359-1365, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27747896

RESUMO

BACKGROUND: Cryoballoon ablation (CBA) for paroxysmal atrial fibrillation (pAF) can be performed under general anesthesia (GA) or moderate sedation (MS). Our objective was to compare the effectiveness, safety, procedure duration, and time spent in the electrophysiology (EP) laboratory for CBA performed under GA and MS. METHODS: Patients undergoing a first CBA for pAF were identified. Patients received either GA administered by an anesthesiologist or MS with midazolam and fentanyl administered by EP laboratory staff. Total time in laboratory (sum of procedure and nonprocedure time); fluoroscopy time; freedom from documented AF, atrial flutter, and atrial tachycardia (FFAF); acute pulmonary vein isolation (PVI) rate; and 30-day complication rate were assessed. RESULTS: A total of 55 patients received GA and 119 patients received MS. PVI success rate was 100% in GA and 98.1% in MS (P = 0.04). Total laboratory time was longer for GA (280.4 ± 54.1 minutes vs 245.5 ± 54.7 minutes; P < 0.001), related to longer nonprocedure time (92.2 ± 28.8 minutes GA vs 71.0 ± 30.0 minutes MS; P < 0.001), but not procedure time (188.3 ± 49.3 minutes GA vs 174.5 ± 50.2 minutes MS; P = 0.09). FFAF was not significantly different over a median follow-up duration of 0.9 (interquartile range 0.4-1.9) years (61.8% GA vs 63.0% MS; log-rank P = 0.90). There was no significant difference in complication rate. CONCLUSION: Compared to GA, MS during CBA for pAF was independently associated with shorter total EP laboratory time without compromising FFAF or complication rates.


Assuntos
Anestesia Geral/estatística & dados numéricos , Fibrilação Atrial/cirurgia , Sedação Consciente/estatística & dados numéricos , Crioterapia/estatística & dados numéricos , Complicações Pós-Operatórias/epidemiologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Ablação por Cateter/estatística & dados numéricos , Técnicas de Laboratório Clínico , Feminino , Humanos , Illinois/epidemiologia , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Segurança do Paciente , Complicações Pós-Operatórias/prevenção & controle , Prevalência , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...