Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 105
Filtrar
1.
Braz. dent. sci ; 26(4): 1-8, 2023. ilus, tab
Artigo em Inglês | BBO - Odontologia, LILACS | ID: biblio-1512140

RESUMO

Objective: To evaluate the biaxial flexural strength (BFS) of lithium disilicate (L), cemented on different substrates (epoxy resin - E and metal - M) with dual-cure resin cement (Rc) and zinc phosphate cement (Zc), not aged, thermally aged (TC) or thermo-mechanical aged (TC/MC). Material and Methods: Disks of L, E, and M were fabricated, and the cementation was performed according to the following groups: ERc (L+E+Rc); MRc (L+M+Rc); MZc (L+M+Zc); EZc (L+E+Zc). Ten samples from each described group were tested in BFS, ten more samples were subjected to TC (1×104 cycles between 5 ºC and 55 ºC water), and the last 10 samples were subjected to TC/MC (MC: 1.2×106 cycles, 50 N, 3.8 Hz). The BFS test was performed and scanning electron microscopy (SEM) was performed to evaluate the failure mode. The effect of the cementation strategy (cement/substrate) was compared in each aging method and the effect of the aging method was evaluated for each cementation strategy by one-way ANOVA and Tukey post-hoc test (α=0.05). Results: The strength values were highest to M (237.8 ~ 463.9 MPa), in comparison to the E (41.03 ~ 66.76 MPa), despite aging and luting agent. Flexural strength data decreased after TC and TC/MC in groups cemented with Zc, but was stable when cemented with Rc. SEM analysis indicated that failure origins were located at the tensile surface of the L. Conclusion: Lithium disilicate discs cemented to the metallic substrate presented the highest biaxial flexural strength. The cementation with dual-cure resin cement did not decrease BFS after aging (AU)


Objetivo: Avaliar a resistência à flexão biaxial (BFS) do dissilicato de lítio (L), cimentado sobre diferentes substratos (resina epóxi - E e metal - M) com cimento resinoso dual (Rc) e cimento de fosfato de zinco (Zc), não envelhecido, submetido ao envelhecido térmico (TC) ou ao envelhecido térmico-mecânico (TC/MC). Material e Métodos: Foram confeccionados discos de L, E e M, e a cimentação foi realizada de acordo com os seguintes grupos: ERc (L+E+Rc); MRc (L+M+Rc); MZc (L+M+Zc); EZc (L+E+Zc). Dez amostras de cada grupo descrito foram testadas em BFS, mais dez amostras foram submetidas à TC (1×104 ciclos de imersão em água entre 5 ºC e 55 ºC), e as últimas 10 amostras foram submetidas à TC/MC (MC: 1.2 ×106 ciclos, 50 N, 3.8 Hz). Foram realizados os testes de BFS e a microscopia eletrônica de varredura (MEV) para avaliar o modo de falha. O efeito da estratégia de cimentação (cimento/substrato) foi comparado em cada método de envelhecimento e o efeito do método de envelhecimento foi avaliado para cada estratégia de cimentação por ANOVA a um fator e teste post-hoc de Tukey (α=0,05). Resultados: Os valores de resistência foram maiores para M (237.8 ~ 463.9 MPa), em comparação com E (41.03 ~ 66.76 MPa), independentemente do envelhecimento e do agente cimentante utilizado. Os dados de resistência à flexão diminuíram após TC e TC/MC nos grupos cimentados com Zc, mas se mantiveram estáveis quando cimentados com Rc. A análise MEV indicou que a origem das falhas estava localizada na superfície de tração do L. Conclusão: Os discos de dissilicato de lítio cimentados ao substrato metálico apresentaram maior resistência à flexão biaxial. A cimentação com cimento resinoso dual não diminuiu o BFS após o envelhecimento (AU)


Assuntos
Envelhecimento , Cimentação , Resistência à Flexão
2.
Biosci. j. (Online) ; 39: e39051, 2023.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1555445

RESUMO

Alternative surface treatments have been proposed for the cementation of lithium disilicate ceramics aiming to improve adhesive and flexural strength under fatigue. This study aimed to evaluate the slow crack growth (SCG) parameters of the lithium disilicate ceramic after hydrofluoric acid (HF) etching or air abrasion (AB) as surface treatments. Ceramic discs were treated with HF (5%, 20 s) or AB (30 µm silica-modified alumina particles, 2.8 bar, 10 mm distance, 15 s), and received a layer of resin cement. The surface roughness after surface treatment was evaluated (n = 5). Samples were tested in a piston-on-three-ball assembly to evaluate the flexural strength (n = 20), inert strength (n = 25), and to determine SCG parameters n and D (n = 35). The highest roughness (p < 0.01) was observed in the AB group, with the highest reliability according to the Weibull analysis, but the lowest SCG susceptibility. Flexural (p = 0.03) and inert strength (p < 0.01) were the greatest in the HF group. Despite exhibiting lower strength than 5% HF, air abrasion may be an alternative for the surface treatment of lithium disilicate surfaces, indicating the best prognosis over time.

3.
Saudi Dent J ; 34(2): 136-141, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35241903

RESUMO

PURPOSE: To simulate biodegradation and wear of stained and glazed CAD lithium disilicate ceramic, and evaluate their effects on the microbial adherence and mechanical and surface properties of lithium disilicate ceramic. MATERIALS AND METHODS: 160 lithium disilicate ceramic discs were fabricated and divided in eight groups according to manual stain and glaze application with a fine paint brush (without stain and glaze; with stain and glaze) and aging procedures (no aging; wear at 30 N load, 1.7 Hz, 3 × 105 cycles; biodegradation by exposure to microcosm biofilm; biodegradation + wear; biodegradation + wear). Profilometry was performed to determine the surface roughness and the wear consequences. Biaxial flexural strength test was performed, and a Streptococcus mutans adherence test was conducted to evaluate the number of colony forming units. RESULTS: Unaged samples with and without stain and glaze presented the lowest values of surface roughness (p < 0.001), but after aging (wear, biodegradation, or both), the samples in the stain and glaze groups were rougher than those in the no stain and glaze groups (p < 0.001). The stain and glaze groups showed the highest volume of wear after aging (p = 0.04), and had the lowest flexural strength values (p < 0.01), irrespective of the aging method. The aging method did not affect the flexural strength (p = 0.06). The number of colonies forming units was higher for biodegradation + no stain and glaze, biodegradation + wear + no stain and glaze, no aging + stain and glaze, biodegradation + stain and glaze, and biodegradation + wear + stain and glaze. The lowest values were observed for no aging + no stain and glaze. CONCLUSION: The staining and glazing of lithium disilicate increased the surface wear and bacterial adherence, and decreased biaxial flexural strength of the material. When exposed to S. mutans, surface roughness increased, and biodegradation favored bacterial adherence.

4.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1385842

RESUMO

ABSTRACT: The aim of this study was to evaluate the influence of overtorque on integrity, strength and stress on external hexagonal implants (EH), with two different grades (N=10): conventional (C), grade 4; and modified (M), grade 4 with thermal treatment. The dimensions of EH were 3.75 x 13 mm; the specimens were fixed and submitted to SEM analysis and image acquisition. The abutment was then retained with 70 N/cm, re-analyzed by SEM, and a second image was obtained. The images were analyzed by Image J software (1.44o- NIH, USA) for dimensional variations measurement on surface of the hexagonal area. The finite element method was applied with a similar compliance to calculate the resultant stress (MPa) during the torque. Results were statistically analyzed with t-student test (5 %). The dimensional accuracy of M (0.22 mm2) was statistically significant (p<0.05). Minimum principal stress and von-Mises stress of C (-19.95 MPa, -19.94 MPa), were lower than M values (-55.83 MPa, -55.96 MPa), respectively. However, the M group showed lower deformation than C group. Therefore, more rigid titanium alloy is a promising alternative to avoid plastic deformation of prosthetic connec tions even concentrating higher stress magnitude on its structure.


RESUMEN: El objetivo de este estudio fue evaluar la influencia del sobrepar en la integridad, la fuerza y la tensión en los implantes hexagonales externos (EH), con dos grados diferentes (N = 10): convencional (C), grado 4; y modificado (M), grado 4 con tratamiento térmico. Las dimensiones de EH eran 3,75 de diámetro x 13 mm de longitud; las muestras se fijaron y se sometieron a análisis SEM y adquisición de imágenes. A continuación, el pilar se retuvo con 70 N / cm, se volvió a analizar por SEM y se obtuvo una segunda imagen. Las imágenes se analizaron con el software Image J (1.44o-NIH, EE. UU.) Para medir las variaciones dimensionales en la superficie superior del área hexagonal, que fue causada por un par excesivo. El método de los elementos finitos se aplicó con un cumplimiento similar para calcular la tensión resultante (MPa) durante el par. Los resultados se analizaron estadísticamente con la prueba t-student (5 %). La precisión dimensional de M (0,22 mm2) fue estadísticamente significativa (p <0,05). La tensión principal mínima y la tensión de von-Mises de C (-19,95 MPa, -19,94 MPa), fueron inferiores a los valores de M (-55,83 MPa, -55,96 MPa), respectivamente. Sin embargo, el hexágono del grupo M mostró menor deformación que el grupo C. Por lo tanto, la aleación de titanio más rígida es una alternativa prometedora para evitar la deformación plástica de las conexiones protésicas incluso concentrando una mayor magnitud de tensión en su estructura.

5.
Minerva Dent Oral Sci ; 70(4): 133-141, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-32181616

RESUMO

BACKGROUND: The cleaning protocol for the ceramic surface after acid etching resulted in a decrease in bond strength and flexural strength of a glass ceramic. This study aims to evaluate the effect of different ceramic surface treatments after hydrofluoric acid etching (HF) on the compressive strength of monolithic lithium disilicate crowns. METHODS: Forty (40) human third molars received conventional full coverage preparation. After performing digital impressions of teeth preparations, ceramic blocks were machined using a CAD/CAM system in order to obtain the crowns. The crowns were distributed in 4 groups as ceramic surface treatment (N.=10): (HF) - 4.9% HF for 20s + air-water spray for 30s; (HFN) - HF + neutralizing agent for 5 min (N); (HFU) - HF + ultrasonic bath for 5 min (U); e (HFNU) - HF + N + U. SEM and EDS analysis was performed in each group in order to characterize the ceramic surface and to verify the chemical element distribution after HF cleaning protocols. A silane layer was applied (for 60s), and crowns were then cemented with dual resin cement. A compressive load was applied on the middle of the occlusal crown surface with a crosshead speed of 1 mm/min until fracture. Data were analyzed using ANOVA and Tukey test (α=0.05). RESULTS: Fluoride ions were found in samples of all postetching cleaning protocols. The mean value (Kgf) was: HF =169.92±21.37; HFN =187.34±34.79; HFU =166.63±40.22 and HFNU=175.26±40.22. The ceramic surface treatment after HF etching did not significantly influence (P>0.05) the compressive strength of the tested ceramic crowns. CONCLUSIONS: Surface treatments with neutralizing agent associated with the ultrasonic bath as the pre-cementation protocol was the most efficient protocol in eliminating the precipitate deposited on the porosities created by acid etching.


Assuntos
Condicionamento Ácido do Dente , Ácido Fluorídrico , Força Compressiva , Porcelana Dentária , Humanos , Teste de Materiais , Propriedades de Superfície
6.
Dent Mater ; 36(5): e149-e157, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32061444

RESUMO

OBJECTIVE: To evaluate the composition, flexural strength and fatigue behaviour of lithium disilicate ceramic (LD) after repeated firings and different staining techniques. METHODS: LD discs were fabricated and divided according to number of firing cycles and staining technique: CO - control, discs were crystallized (850°C/10min); SC - single-step characterization - crystallization and staining (applied with a thin brush) were performed in a single step with one firing cycle (850°C/10min); and DC - double-step characterization - crystallization firing cycle was performed first (850°C/10min), followed by staining firing cycle (770°C/90s). Specimens were fired two, four or six times (one crystallization firing cycle and one, three or five staining firing cycles), resulting into 9 groups (n=30): COII, COIV, COVI, SCII, SCIV, SCVI, DCII, DCIV and DCVI. The composition of the specimens was investigated (EDS, XRD, Raman spectroscopy), and the biaxial flexural strength (n=10) and staircase tests (n=20, 5×104 cycles, 5Hz) were performed. Data were subjected to one-way ANOVA and Tukey's test (α=0.05). RESULTS: EDS and XRD revealed amorphous content for stained groups. Biaxial flexural strength was not affected by repeated firings in any group, but stained groups presented lower flexural strength than control groups (p=0.001). The fatigue limit results decreased in all groups compared to flexural strength. SC groups showed similar (SCII and SCIV) or even higher fatigue limits (SCVI) than the control groups, and DC showed the lowest fatigue limit values. SEM and Raman suggested that the interfaces between staining and the LD showed only an overlap for the DC groups, whereas for the SC it was suggested an interaction between the stain and the LD. SIGNIFICANCE: Repeated firings did not result in decreased lithium disilicate flexural strength.Staining affected flexural strength and also resulted in increased amorphous content in the characterized specimens. Single-step staining resulted in the highest fatigue limit.


Assuntos
Cerâmica , Porcelana Dentária , Teste de Materiais , Coloração e Rotulagem , Propriedades de Superfície
7.
J Esthet Restor Dent ; 32(1): 113-118, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31854512

RESUMO

OBJECTIVE: Evaluate the effect of staining and repeated firings on color, translucency and surface proprieties of CAD/CAM lithium disilicate (LD). MATERIAL AND METHODS: One hundred eighty LD discs were made (ISO 6872) and distributed in different groups (n = 20): control (CO)-no treatment; single-step characterization (SC)-crystallization and staining fired together; and double step characterization (DC)-crystallization and then staining. The samples were submitted to two, four, or six firings, resulting in nine groups: COII, COIV, COVI, SCII, SCIV, SCVI, DCII, DCIV, and DCVI. The color and translucency were measured by a reflectance spectrophotometer. Surface roughness (Ra) and Vickers nano-hardness were also measured. ANOVA and Tukey statistical tests were used (α = .05). RESULTS: Only CO and DC demonstrated significant color alterations (ΔE00 > 1.8). SC and DC did not show changes in translucency by the number of firings (P > .05); however, for CO (P = .02) these values increased. Nano-hardness was similar in all groups (P > .05). Ra values indicated differences due to the type of characterization (SC presented the highest values) and number of firings (CO and DC groups) (P < .01). CONCLUSION: SC promoted color, translucency, and roughness stability after repeated firings. CLINICAL SIGNIFICANCE: The single characterization technic in CAD/CAM lithium disilicate presents good color, translucency, and hardness stability, which promote predictable results to monolithic restoration.


Assuntos
Cerâmica , Porcelana Dentária , Cor , Desenho Assistido por Computador , Teste de Materiais , Coloração e Rotulagem , Propriedades de Superfície
8.
Arq. odontol ; 56: 1-8, jan.-dez. 2020. ilus, tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1097768

RESUMO

Aim: To evaluate the influence of lengths and different luting agents on the bond strength of fiberglass posts' adhesion to dentin.Methods: Sixty single-root bovine teeth were endodontically treated and included in polyether and acrilyc resin to simulate a periodontal ligament. These were divided into 6 groups according to the post lengths (6, 10 or 14 mm) and luting agents (self-adhesive dual resin cement ­ U; or etch-and-rinse dual resin cement ­ A): U6, U10, U14, A6, A19, and A14. All fiberglass posts were cemented according to manufacturer instructions. After this, mechanical aging was performed (1.2x106 cycles; 4 Hz, 90 N). The push-out specimens were then conducted (2.0 ± 0.1 mm), with the test executed in a universal machine (10 kgf at 0.5 mm/min). Data obtained were submitted to the Kruskal-Wallis and Dunn's test. Results: No statistically significant difference was observed in bond strength between the groups due to the type of luting agent (p > 0.05). However, the isolated post-length factor showed significantly different results for the U groups (p < 0.05). The U10 group showed similar union values to U6 but statistically inferior to U14. Conclusion: bond strength of fiberglass posts of the same length as the dentin presented no differences according to the luting agent, but the post-length property influenced the bond strength when self-adhesive resin cement was used.


Objetivo: avaliar a influência dos agentes cimentantes e dos diferentes comprimentos de pinos na resistência de união de pinos de fibra de vidro a dentina. Métodos: Sessenta dentes bovinos uniradiculares tiveram a raiz endodonticamente tratada, e foram incluídos em poliéter e resina acrílica para simular o ligamento periodontal. Os espécimes foram divididos em seis grupos de acordo com o comprimento dos pinos (6, 10 ou 14mm) e dos agentes de cimentantes (cimento resinoso dual autoadesivo (RelyX U200, 3M ESPE) - U; ou cimento resinoso dual convencional (AllCem Core, FGM) - A: U6, U10, U14, A6, A19 e A14. Todos os pinos de fibra de vidro foram cimentados conforme as recomendações do fabricante. Após, o envelhecimento mecânico (1,2x106 ciclos; 4 Hz, 90 N) as amostras foram fatiadas para o teste de push-out (2,0 ± 0,1 mm) executado em uma máquina de ensaio universal (10 kgf a 0,5 mm/min). Os dados foram submetidos ao teste de Kruskal-Wallis e Dunn. Resultados: não houve diferença estatística na resistência de união entre os grupos devido ao tipo de agente cimentante (p > 0,05), mas houve para o comprimento dos pinos dos grupos U (p < 0,05). O grupo U10 apresentou valores de união semelhantes a U6, mas estatisticamente inferiores ao U14. Conclusão: a resistência de união dos pinos de fibra de vidro de um mesmo comprimento não apresentou diferenças mesmo quando cimentados com cimentos diferentes, mas o comprimento dos pinos isoladamente influenciou quando o cimento resinoso autoadesivo foi utilizado.


Assuntos
Resinas Acrílicas , Teste de Materiais , Cimentos de Resina , Cimentos Dentários , Ciência dos Materiais , Cimentos de Ionômeros de Vidro , Pinos Dentários
9.
RGO (Porto Alegre) ; 68: e20200001, 2020. tab
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1091892

RESUMO

ABSTRACT Objective Evaluate the influence of silane heat treatment in bond durability between two resin cements and CAD/CAM feldspathic ceramic. Methods 40 feldspathic ceramic blocks were obtained, and were duplicated in microhybrid composite. All ceramic blocks were etched with 10% hydrofluoric acid for 20 s and received application of silane agent. The blocks were randomizedinto eight groups (n=5) according to the surface treatments and luting agents: P- Panavia F; PAg- Panavia F + Aging; HP- Heat Treatment + Panavia F; HPAg- Heat Treatment + Panavia F + Aging; R- RelyX ARC; Rag- RelyX ARC + Aging; HR- Heat Treatment + RelyX ARC; HRAg- Heat Treatment + RelyX ARC + Aging. The heat treatment was performed in furnace at 100 °C for 2 min. All blocks were cemented and cut to obtain samples with adhesive area of 1 mm2. Aging was performed with 10000 thermal cycles. The samples were subjected to microtensile bond strength test. Results The three-way ANOVA test revealed a significant interaction between cement versus heat treatment (p=0.001) and heat treatment versus thermal cycling (p=0.001) indicating that there was a change in bond strength due to surface treatment and aging. Conclusion Therefore, the heat treatment of the silane at 100 ºC for 2 minutes obtained higher values of bond strength between the resin cement and a feldspathic ceramicafter aging.


RESUMO Objetivo Avaliar a influência do tratamento térmico do silano na resistência de união entre dois cimentos resinosos e uma cerâmica feldspática CAD/CAM. Métodos Quarenta blocos cerâmicos foram duplicados em resina micro-híbrida. Todas as cerâmicas foram condicionadas com ácido fluorídrico 10% por 20 s e receberam aplicação do silano. Os blocos foram randomizados em oito grupos (n = 5): P-Panavia F; PAg- Panavia F + Envelhecimento; HP-Tratamento térmico + Panavia F;HPAg-Tratamento térmico + Panavia F + Envelhecimento; R-RelyX ARC; RAg-RelyX ARC; HR-Tratamento térmico + RelyX ARC; HRAg - Tratamento térmico + RelyX ARC + Envelhecimento. O tratamento térmico foi realizado em forno a 100 °C durante2 min. Todos os blocos foram cimentados e cortados para obter amostras para microtração. Foram feitos 10000 ciclos térmicos. As amostras foram submetidas a teste de micro-tração. Resultados O teste ANOVA revelou uma interação significativa entre cimento/tratamento térmico (p=0,001) e tratamento térmico/ciclo térmico (p=0,001). Conclusão Dessa maneira, o tratamentotérmico do silano a 100ºC por 2 minutos foi capaz de aumentar a resistência de união entre o cimento resinoso e uma cerâmica feldspática mesmo após o envelhecimento.

10.
Braz. j. oral sci ; 18: e191504, jan.-dez. 2019. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1094897

RESUMO

Aim: evaluate the influence of etching time with hydrofluoric acid on the bond strength of a Yttrium-stabilized polycrystalline tetragonal zirconia (Y-TZP) ceramic with a superficial glaze layer and a resin cement. Methods: Y-TZP blocks were cut to obtain 40 samples. They were distributed into four groups (n = 10): control treated by sandblasting with silica-coated alumina (RS) and three glazed experimental groups with different etching times: GS20s, GS60s and GS100s. Cementation was done with a universal adhesive and a resin cement. Two cement cylinders were made in each block. After thermocycling, the shear bond test was performed. Two extra samples of each group were made to obtain profilometry, scanning electron microscopy, mapping and backscattered electron detector images. Energy dispersive spectrometry and goniometry were also performed. Results: Kruskal-Wallis and Dunn tests demonstrated bond strength differences only between the RS (22.10MPa) and the GS groups (GS20s: 8,10Mpa; GS60s: 10.49MPa; GS100s: 7.53MPa) (p = 0.001), but there was no difference among the experimental groups (p > 0.05). The contact angles were 55.33º (RS); 70.78° (GS100s); 48.20º (GS60s) and 28.73º (GS20s). ANOVA and Tukey test demonstrated similar wettability of RS to GS60s and GS100s (p > 0.05), but all the experimental groups were statistically different between them (p < 0.001). Qualitative image analysis revealed an irregular glaze distribution after etching. The thickness of the remaining glaze layer measured by profilometry was 5±1µm (GS20S), 4±1µm (GS60S) and 3±1µm (GS100s). Conclusion: The etching time of glazed zirconia did not influence the adhesive strength of the ceramic to the resin cement


Assuntos
Zircônio , Cimentos Dentários , Vidro
11.
Braz. dent. sci ; 22(4): 573-577, 2019. ilus
Artigo em Inglês | BBO - Odontologia, LILACS | ID: biblio-1024963

RESUMO

Accurate color selection of direct or indirect dental restorations is a subjective task. Mobile phones are tools that may minimize color assessment errors. The objective was to use photographs taken with smartphones to guide the dental surgeon in choosing the right color in oral rehabilitation. A tooth was photographed for color assessment and the VITA Toothguide 3D-MASTER® shade guide was used. Photographs were submitted to an image editing software for full saturation removal. Images of the tooth and scale in black and white were compared. This method allowed to select the tooth's value, which is considered the most subjective dimension in color choice. Although it is an auxiliary and complementary method to traditional methods, smartphones are tools capable of reducing the range of color possibilities and minimizing possible failures (AU)


A correta seleção da cor das restaurações dentais diretas ou indiretas é uma atividade subjetiva. Os celulares são ferramentas que podem minimizar os erros da tomada de cor. O objetivo foi utilizar fotografias realizadas com smartphones para orientar o cirurgião-dentista na escolha da cor em reabilitação oral. Foi fotografado um dente para tomada de cor e a escala Vita 3D Master. As imagens foram submetidas a um software de edição de imagem para remoção total da saturação. As imagens em preto e branco do dente e da escala foram comparadas. A metodologia permitiu selecionar o valor do dente que é o aspecto considerado mais subjetivo na escolha da cor. Apesar de ser um método auxiliar e complementar aos métodos tradicionais é uma ferramenta capaz de diminuir o leque de possibilidades de cores e minimizar possíveis falhas (AU)


Assuntos
Dente , Cor , Fotografia Dentária , Telefone Celular
12.
Braz. dent. sci ; 22(3): 305-312, 2019. tab, ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1008364

RESUMO

Objective: The aim of the study was to evaluate the influence of different surface post-etching treatments in flexural strength, contact angle and surface roughness of a lithium disilicate ceramic. Material and Methods: 60 bars (16 x 2 x 4 mm) were divided in six groups (n=10): C, no treatment; HF, hydrofluoric acid for 20 s (HF) + washing (60 s), drying (30s); HFL, HF + washing (60 s), drying (30 s) and luting; HFNL, HF + washing (60 s) + neutralization with sodium bicarbonate (SB) for 40 s + washing (5s), drying (30 s) and luting; HFUL, HF + washing (60 s) + ultrasonic bath (UB) for 4 min, drying (30 s) and luting; HFNUL, HF + washing (60 s) + SB (40 s) + UB (4 min) and luting. The bars were submitted to three-points flexural strength test. 25 ceramic blocks (12 x 7 x 7 mm) were divided into five groups (n=5) to evaluate roughness and contact angle C - no treatment; HF - HF ; HFU - HF and UB for 5 min ; HFN - HF and SB; HFNU - HF, UB and SB. A scanning electron microscope (SEM) showed the surface of the samples. ANOVA one-way statistical analysis was done for comparison of results. Results: There was no statistical difference for flexural strength (p-value = 0.15) and for surface roughness (p-valor = 0.15). However, it was obtained statistically significant difference for contact angle (p-valor = 0.00). SEM images showed precipitates after the acid etching, which were removed by post-etching treatments. Conclusion: It can be concluded that the different post-etching surface treatments did not increase the flexural strength, surface roughness, but it influenced the ceramic wetting and SEM images (AU)


Objetivo: O objetivo do estudo foi avaliar a influência de diferentes tratamentos pós-condicionamento na resistência à flexão, ângulo de contato e rugosidade superficial de uma cerâmica de dissilicato de lítio. Material e Métodos: 60 barras (16 x 2 x 4 mm) foram divididas em seis grupos (n = 10): C, sem tratamento; HF, ácido fluorídrico durante 20 s (HF) + lavagem (60 s), secagem (30 s); HFL, lavagem com HF + (60 s), secagem (30 s) e cimentação; HFNL, HF + lavagem (60 s) + neutralização com bicarbonato de sódio (SB) por 40 s + lavagem (5s), secagem (30 s) e cimentação; HFUL, HF + lavagem (60 s) + banho ultrassônico (UB) por 4 min, secagem (30 s) e cimentação; HFNUL, HF + lavagem (60 s) + SB (40 s) + UB (4 min) e cimentação. As barras foram submetidas ao teste de resistência à flexão de três pontos. 25 blocos cerâmicos (12 x 7 x 7 mm) foram divididos em cinco grupos (n = 5) para avaliação da rugosidade superficial e ângulo de contato C - sem tratamento; HF - HF; HFU - HF e UB por 5 min; HFN - HF e SB; HFNU - HF, UB e SB. Um microscópio eletrônico de varredura (MEV) foi utilizado para análise da superfície das amostras. A análise estatística unidirecional ANOVA-um fator foi realizada para comparação dos resultados. Resultados: Não houve diferença estatística para a resistência à flexão (p-valor = 0,15) e para a rugosidade superficial (p-valor = 0,15). No entanto, obteve-se diferença estatisticamente significante para o ângulo de contato (p-valor = 0,00). Imagens de microscopia eletrônica de varredura mostraram a formação de precipitados após o ataque ácido, que foram removidos pelos tratamentos pós-condicionamento. Conclusão: Pode-se concluir que os diferentes tratamentos de superfície pós-condicionamento não aumentaram a resistência à flexão, rugosidade da superfície, mas influenciaram na molhabilidade da cerâmica e nas imagens em MEV.(AU)


Assuntos
Tomografia com Microscopia Eletrônica , Resistência à Flexão , Ácido Fluorídrico
13.
Rev. odontol. UNESP (Online) ; 47(6): 348-353, nov.-dez. 2018. tab, ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-985735

RESUMO

Introduction: Despite being one of the most studied ceramics today, zirconia still does not have a well-defined adhesion protocol. Objective: Evaluate the influence of different etching times and hydrofluoric acid (HF) concentrations on the zirconia surface and bond strength between a vitrified Y-TZP ceramic and a resin cement. Materials and method: The zirconia surface treatments were: sandblasting with silica-coated alumina (Co); glaze application + 5% HF etching for 5s (G5-5s), 10s (G5-10s) or 20s (G5-20s); glaze application + 10% HF etching for 5s (G10-5s), 10 (G10-10s) or 20s (G10-20s) . Then, cement cylinders (3.3 × 3.3 mm) were built up for shear bond test on all specimens. The specimens were subjected to 6000 thermal cycling before the test. Fractures were analyzed by stereomicroscope. Data were statistically analyzed by Kruskal-Wallis and Dunn statistical tests (5%). Extra samples of each group were made to obtain profilometry and scanning electron microscopy (SEM). Result: Zirconia-cement bond strength was affected by the ceramic surface treatments (p = 0.001). G10-5s (2.71 MPa) recorded the highest bond strength values, followed by the Co (2.05 MPa) while G5 groups had the lowest bond value. Adhesive failure of the samples predominated. The image analysis revealed G5 groups seem to have a lower roughness when compared to groups treated by 10% HF. The creation of pores in the low-fusing porcelain glass layer surface occurred only when 10% HF was used. Conclusion: The low-fusing porcelain glass layer application was able to overcome the sandblasting and obtain a greater adhesive bond to the resinous cement, however, only when 10% HF was used for an interval of 5 seconds.


Introdução: Apesar de ser uma das cerâmicas mais estudadas atualmente, a zircônia ainda não possui um protocolo bem definido para uma cimentação adesiva. Objetivo: Avaliar a influência de diferentes tempos de condicionamento e concentrações do ácido fluorídrico (AF) na superfície da zirconia e na resistência de união entre uma cerâmica Y-TZP vitrificada e um cimento resinoso. Material e método: Os tratamentos de superfície foram: jateamento com óxido de alumínio revestido com sílica (Co); aplicação de glaze + condicionamento com AF 5% por 5s (G5-5s), 10s (G5-10s) ou 20s (G5-20s); aplicação de glaze + condicionamento com AF 10% por 5s (G10-5s), 10 (G10-10s) ou 20s (G10-20s). Em seguida, cilindros de cimento (3,3 × 3,3mm) para teste de cisalhamento foram feitos em todos os espécimes. Os espécimes foram submetidos a 6000 ciclos térmicos antes do teste de adesão. As fraturas foram analisadas por estereomicroscópio. Os dados foram analisados ​​estatisticamente por Kruskal-Wallis e Dunn (5%). Amostras extra de cada grupo foram feitas para realização de perfilometria e microscopia eletrônica de varredura (MEV). Resultado: A resistência de união zircônia-cimento foi afetada pelos tratamentos de superfície (p = 0,001). Os grupos G10-5s (2,71 MPa) registraram os maiores valores de resistência de união, seguidos pelos Co (2,05 MPa), enquanto os grupos G5 apresentaram o menor valor de união. Falhas adesivas foram predominantes. As análises por imagem revelaram que os grupos G5 parecem ser menos rugosos quando comparados aos grupos tratados com AF 10%. A criação de poros na superfície vítrea (glaze) ocorreu apenas quando foi utilizado AF 10%. Conclusão: A aplicação de camada de vidro de porcelana de baixa fusão foi capaz de superar o jateamento e obter uma maior adesão adesiva ao cimento resinoso, no entanto, somente quando foi utilizado 10% de HF por um intervalo de 5 segundos.


Assuntos
Zircônio , Microscopia Eletrônica de Varredura , Abrasão Dental por Ar , Cimentos Dentários , Porcelana Dentária , Ácido Fluorídrico , Cerâmica , Estatísticas não Paramétricas
14.
Braz Oral Res ; 32: e34, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29742232

RESUMO

To evaluate the effect of different surface treatments on the marginal misfit and retentive strength between Y-TZP crowns and an epoxy resin. Forty (40) epoxy resin (G10) abutments (height: 5mm, conicity: 60, finish line: large chamfer) with equal dimensions were milled and included in polyurethane to simulate the periodontal ligament. Next, 40 Y-TZP crowns (thickness: 1mm) were milled (Cerec in Lab) and randomly divided into four groups (n=10) according to the surface treatment: GS(glaze spray), GP(glaze powder/liquid), P(zirconia primer) and RS(tribochemical silica coating). The conditioned surfaces were cemented with dual self-adhesive cement, light cured and submitted to thermomechanical cycling (2x106, 100N, 4Hz, 5°/55°C). Marginal misfit was analyzed by a stereomicroscope and SEM. Retentive strength test was performed (1mm/min) until crown debonding. Glaze layer thickness was also performed to GS and GP groups. Marginal misfit data were analyzed by Kruskal Wallis and Dunn tests; one-way ANOVA and Tukey (5%) analyzed the tensile strength data. The marginal misfit of the GS (48.6±19.9µm) and GP (65.4±42.5µm) were statistically lower than the RS (96±62.9µm) and P (156±113.3µm) (p=0.001). The retentive strength of the GP (470.5±104.1N) and GS (416.8±170.2N) were similar to the P (342.1±109.7N), but statistically higher than those of the RS (208.9±110N). The GS and GP glaze layer was 11.64µm and 9.73µm respectively. Thus, glaze application promoted lower marginal discrepancy and higher retentive strength values than conventional techniques.


Assuntos
Coroas , Colagem Dentária/métodos , Adaptação Marginal Dentária , Resinas Epóxi/química , Vidro/química , Ítrio/química , Zircônio/química , Análise de Variância , Desenho Assistido por Computador , Falha de Restauração Dentária , Teste de Materiais , Microscopia Eletrônica de Varredura , Valores de Referência , Reprodutibilidade dos Testes , Estatísticas não Paramétricas , Propriedades de Superfície , Resistência à Tração
15.
J Mech Behav Biomed Mater ; 81: 173-177, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29525667

RESUMO

The aim of this study was compare the effect of two in vitro ageing protocols to intraoral aging on the flexural strength of a lithium disilicate (LD) ceramic bars with clamped ends. After polishing and crystallization, the both ends of the bars were cemented to a metallic device and subjected to mechanical cycling, thermomechanical cycling, or intraoral ageing. Ten volunteers used an intraoral device - similar to an occlusal splint with a balanced contact condition on the occlusal surface of the ceramic bar - during 8 h night time / 30 days. Both in vitro and intraoral ageing decreased the flexural residual strength of LD, with the lowest values obtained after intraoral ageing. Thus, the in vitro ageing protocols tested in this study revealed to be less deleterious than intraoral ageing of LD.


Assuntos
Porcelana Dentária , Resistência à Flexão , Teste de Materiais , Cerâmica , Fatores de Tempo
16.
Braz. dent. sci ; 21(3): 302-306, 2018. tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-911402

RESUMO

Objective: Evaluate the influence of different disinfection methods on the dimensional stability of temporary acrylic resin crowns. Material and Methods: A metallic die with two different marks at the margin was used to prepare the specimens with two different resins (bis-acrylic resin-Structur, acrylic resin-Dencrilay). They were divided into eight groups (n=8), determined according to the disinfection methods (microwave, acetic acid, 1% hypochlorite) and control. The marginal adaptation was recorded using an optical microscope (50X) comparing two different marks on the margin of the crowns with 2 points along the entire circumferential margin before and after disinfection methods. Results: Results were compared statistically by ANOVA and Tukey's test (p≤0.05). The two-way ANOVA showed statistical difference between types of materials. No significant differences were found between disinfection methods and interaction of factors. Conclusion: All procedures affected the marginal adaptation however temporary crowns made by bis-acrylic resin demonstrate higher dimensional stability. (AU)


Objetivo: Avaliar a influência de diferentes métodos de desinfecção na estabilidade dimensional de coroas temporárias de resina acrílica. Material e Métodos: um molde metálico com duas marcas diferentes na margem foi utilizado para preparar os espécimes com duas resinas diferentes (resina bis-acrílica - estrutura, resina acrílica-Dencrilay). Eles foram divididos em oito grupos (n = 8), determinados de acordo com os métodos de desinfecção (microondas, ácido acético, 1% de hipoclorito) e controle. A adaptação marginal foi registrada usando um microscópio óptico (50X) comparando duas marcas diferentes na margem das coroas com 2 pontos ao longo de toda a margem circunferencial antes e após os métodos de desinfecção. Resultados: os resultados foram comparados estatisticamente por ANOVA e teste de Tukey (p≤0,05). A ANOVA de dois fatores mostrou diferença estatística entre os materiais utilizados. Não foram encontradas diferenças significativas entre os métodos de desinfecção e a interação dos fatores. Conclusão: Todos os procedimentos afetaram a adaptação marginal, porém as coroas temporárias feitas em resina bis-acrílica demonstram maior estabilidade dimensional. (AU)


Assuntos
Resinas Acrílicas , Materiais Biomédicos e Odontológicos , Materiais Dentários , Desinfecção , Coroa do Dente
17.
Braz. dent. sci ; 21(3): 315-319, 2018. tab, ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-911407

RESUMO

Objective: The aim of the study was to evaluate the effect of aging through different thermocycling protocols on the flexural strength of a feldspathic ceramic. Material and Methods: Fifty ceramic bars, Vitablock Mark II (VITA), with dimensions of 18X4X2mm were prepared. The bars were randomly distributed to the groups (n = 10), which were defined according to the number of thermal cycles (TCy): G0 - no TCy; G500 - 500 cycles of TCy; G6000 - 6000 TCy; G10000 - 10000 TCy; G15000 - 15000 TCy. After aging, the specimens were subjected to the three point bending test in a universal testing machine (EMIC DL 1000), under 0.5mm/min speed and loading of 50kgf, until catastrophic failure. A sample of each group was evaluated for topographic morphology under Scanning Electron Microscopy. Results: For mechanical testing, the following mean values and standard deviation (MPa) were obtained: G0 (99.78 ± 5.07); G500 (101.64 ± 5.59); G6000 (98.13 ± 4.95); G10000 (91.77 ± 9.68); G15000 (101.51 ± 4.22). An analysis of variance by regression equation (p = 0.387) was performed, demonstrating a weak and non-significant correlation between flexural strength and number of thermal cycles. Conclusion: It can be concluded that aging in water solely by different numbers of temperature cycles did not influence on the flexural strength of a feldspathic ceramic. (AU)


Objetivo: O objetivo do estudo foi avaliar o efeito do envelhecimento por meio de diferentes protocolos de ciclos térmicos na resistência à flexão de uma cerâmica feldspática. Material e Métodos: Cinquenta barras de cerâmica, Vitablock Mark II (VITA), com dimensões de 18X4X2mm foram preparadas. As barras foram distribuídas aleatoriamente pelos grupos (n = 10), os quais foram definidos de acordo com o número de ciclos térmicos (CT): G0 ­ nenhum; G500 - 500 CT; G6000 - 6000 CT; G10000 ­ 10000 CT; G15000 - 15000 CT. Após envelhecimento, as amostras foram submetidas ao ensaio de flexão de três pontos em uma máquina de ensaios universal (EMIC DL 1000), sob a velocidade de 0,5 mm / min e célula de carga de 50kgf, até uma falha catastrófica. Uma amostra de cada grupo foi avaliada quanto à morfologia topográfica sob microscopia eletrônica de varredura. Resultados: Para os testes mecânicos, foram obtidos os seguintes valores médios e desvio padrão (MPa): G0 (99,78 ± 5,07); G500 (101,64 ± 5,59); G6000 (98,13 ± 4,95); G10000 (91,77 ± 9,68); G15000 (101,51 ± 4,22). Uma análise de variância pela equação de regressão (p = 0,387) foi realizada, o que demonstra uma correlação fraca e não significativa entre a resistência à flexão e do número de ciclos térmicos. Conclusão: Pode-se concluir que o envelhecimento somente em água por diferentes números de ciclos térmicos não influenciou na resistência à flexão de uma cerâmica feldspática (AU)


Assuntos
Envelhecimento , Ciência dos Materiais , Ligas Metalo-Cerâmicas , Microscopia Eletrônica de Varredura
18.
Braz. oral res. (Online) ; 32: e34, 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-889480

RESUMO

Abstract To evaluate the effect of different surface treatments on the marginal misfit and retentive strength between Y-TZP crowns and an epoxy resin. Forty (40) epoxy resin (G10) abutments (height: 5mm, conicity: 60, finish line: large chamfer) with equal dimensions were milled and included in polyurethane to simulate the periodontal ligament. Next, 40 Y-TZP crowns (thickness: 1mm) were milled (Cerec in Lab) and randomly divided into four groups (n=10) according to the surface treatment: GS(glaze spray), GP(glaze powder/liquid), P(zirconia primer) and RS(tribochemical silica coating). The conditioned surfaces were cemented with dual self-adhesive cement, light cured and submitted to thermomechanical cycling (2x106, 100N, 4Hz, 5°/55°C). Marginal misfit was analyzed by a stereomicroscope and SEM. Retentive strength test was performed (1mm/min) until crown debonding. Glaze layer thickness was also performed to GS and GP groups. Marginal misfit data were analyzed by Kruskal Wallis and Dunn tests; one-way ANOVA and Tukey (5%) analyzed the tensile strength data. The marginal misfit of the GS (48.6±19.9μm) and GP (65.4±42.5μm) were statistically lower than the RS (96±62.9μm) and P (156±113.3μm) (p=0.001). The retentive strength of the GP (470.5±104.1N) and GS (416.8±170.2N) were similar to the P (342.1±109.7N), but statistically higher than those of the RS (208.9±110N). The GS and GP glaze layer was 11.64μm and 9.73μm respectively. Thus, glaze application promoted lower marginal discrepancy and higher retentive strength values than conventional techniques.


Assuntos
Coroas , Colagem Dentária/métodos , Adaptação Marginal Dentária , Resinas Epóxi/química , Vidro/química , Ítrio/química , Zircônio/química , Análise de Variância , Desenho Assistido por Computador , Falha de Restauração Dentária , Teste de Materiais , Microscopia Eletrônica de Varredura , Valores de Referência , Reprodutibilidade dos Testes , Estatísticas não Paramétricas , Propriedades de Superfície , Resistência à Tração
19.
Braz. dent. sci ; 21(2): 150-156, 2018. ilus, tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-906051

RESUMO

Objective: This research aimed to verify the performance of thermally activated acrylic resin (TAAR) combined with a mix of glass and aramid fibers and/or composite resin of indirect use by a tree point bending test. Material and Methods: Ten samples, with 65 x 10 x 2.5 mm, were prepared for each group (n = 10): CO, control of only TAAR; CR, in which an 60 mm indirect composite resin was polymerized together with the acrylic resin during the thermo-polymerization cycle; SS, in which ceramic glass mixed with aramid fibers cut 60 mm in length were incorporated into the samples; and SC, in which the same fibers were incorporated with addiction of the indirect composite resin. A three point flexural strength test was performed with a universal testing machine with a load of 50KgF at a speed of 5 mm/min in the center of the samples supported by a suitable device. The reinforced face was placed to the tensile side. The statistical one way ANOVA and Tukey tests were made with a significance level of 95%. Results: The mean value for the CO was 60,27 ± 24,18 MPa, for CR it was 38,39±12,75 MPa, for SS it was 79,97±12,75 Mpa and for CS it was 32,40±9,05 MPa. Conclusion: The use of glass and aramid fibers at the base of a TAAR increased the three-point flexural strength, however when indirect composite resin was incorporated, a significant drop of this mechanical property was observed. (AU)


Objetivo: Esta pesquisa teve como objetivo verificar o desempenho de uma resina acrílica ativada termicamente (RAAT) combinada com uma mistura de fibras de vidro e aramida e / ou resina composta de uso indireto por um teste de flexão de três pontos. Material e Métodos: Foram preparadas dez amostras, com 65 x 10 x 2,5 mm, para cada grupo (n = 10): CO, controle com apenas RAAT; CR, em que uma resina composta indireta de 60 mm com polimerizada em conjunto com a resina acrílica durante o ciclo de termopolimerização; SS, em que o vidro cerâmico misturado com fibras de aramida cortadas com 60 mm de comprimento foi incorporado nas amostras; e SC, nas quais as mesmas fibras foram incorporadas em conjunto com a resina composta indireta. O teste de resistência à flexão de três pontos foi realizado em uma máquina de teste universal com uma carga de 50 KgF a uma velocidade de 5 mm/min no centro das amostras suportadas por um dispositivo adequado. A face reforçado foi colocado no lado da tração. Os testes estatísticos one-way ANOVA e Tukey foram feitos com um nível de significância de 95%. Resultados: O valor para o CO foi de 60,27 ± 24,18 MPa, para CR foi de 38,39 ± 12,75 MPa, para SS foi de 79,97 ± 12,75 Mpa e para CS foi de 32, 40 ± 9,05 MPa. Conclusão: o uso de fibras de vidro e aramida na base de uma RAAT aumentou a resistência à flexão de três pontos, no entanto, quando a resina composta indireta foi incorporada, observou-se uma queda significativa dessa propriedade mecânica (AU)


Assuntos
Resinas Acrílicas , Resinas Compostas , Prótese Total
20.
HU rev ; 43(1): 33-38, ago. 2017.
Artigo em Português | LILACS | ID: biblio-859302

RESUMO

[{"text": "desdentados, apesar de ser considerada facilitadora de várias patologias bucais. Assim, o objetivo deste estudo foi conhecer os hábitos de higiene bucal dos usuários de PTR, o estado de conservação associado à presença de lesões bucais e o recebimento de orientação profissional. Sessenta usuários de PTR foram entrevistados e suas próteses avaliadas quanto à higiene, conservação e saúde bucal. Observou-se que 96,7% dos pesquisados não receberam orientação profissional, o método mecânico foi o mais utilizado para higienização e realizado três vezes ao dia (36,7%). A higiene das PTR apresentou-se moderada e as características funcionais estavam insatisfatórias. A queilite angular não teve significância estatística quando associada ao nível de higiene. A ausência de retenção e estabilidade estática associou com as lesões no maxilar inferior (p=0,02). As características deficientes das PTR representam uma tendência para a ocorrência de lesões bucais e os participantes, apesar da higiene frequente, não conheciam a forma correta de higienização e não receberam orientação que a PTR poderia causar lesões bucais.", "_i": "pt"}]


Assuntos
Higiene Bucal , Prótese Total , Patologia Bucal
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA