Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Asian Cardiovasc Thorac Ann ; 30(9): 985-991, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36112800

RESUMO

BACKGROUND: Although there is a trend toward direct transcatheter aortic valve implantation (TAVI), still balloon predilatation is necessary in some cases, especially in patients with severe calcification. However, predilatation including rapid ventricular pacing may have adverse outcomes, especially in patients with reduced ejection factor (EF). OBJECTIVE: To evaluate the impact of predilatation on in-hospital outcomes in patients with reduced versus preserved EF underwent TAVI. METHODS: This was a prospective observational study including 110 patients (72 patients with preserved EF (≥50%) and 38 patients with reduced EF (<50%)) who underwent TAVI. The two groups were compared regarding in-hospital outcomes. RESULTS: Predilatation was done routinely in all 110 patients. The mean age was significantly higher in patients with preserved EF (82.76 ± 5.74 vs. 80.13 ± 6.51 years; p = 0.03). The majority (51.4%) of patients with preserved EF were females but the majority (73.7%) of those with reduced EF were males (P < 0.001). Predilatation showed no statistical difference regarding in-hospital mortality (2.6% vs. 1.4%; p = 0.29), hemodynamic instability (5.3% vs. 0.0%; p = 0.11), stroke (0% vs. 1.4%; p = 0.67), conduction defects (13.2% vs. 19.4%; p = 0.29), permanent pacemaker implantation (7.9% vs. 5.5%; p = 0.45), paravalvular leakage (5.3% vs. 2.8%; p = 0.42), vascular complications (7.9% vs. 11.1%; p = 0.43), and acute kidney injury (7.9% vs. 7%; p = 0.4) in patients with reduced versus preserved EF, respectively. CONCLUSION: When balloon predilatation is inevitable during TAVI it is safe in patients with reduced as well as preserved EF with no added risk of hemodynamic instability or other outcomes.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Masculino , Volume Sistólico , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Função Ventricular Esquerda
2.
JACC Cardiovasc Interv ; 15(15): 1543-1554, 2022 08 08.
Artigo em Inglês | MEDLINE | ID: mdl-35926921

RESUMO

BACKGROUND: As transcatheter aortic valve (TAV) replacement is increasingly used in patients with longer life expectancy, a sizable proportion will require redo TAV replacement (TAVR). The unique configuration of balloon-expandable TAV (bTAV) vs a self-expanding TAV (sTAV) potentially affects TAV-in-TAV outcome. OBJECTIVES: The purpose of this study was to better inform prosthesis selection, TAV-in-TAV outcomes were assessed according to the type of initial and subsequent TAV. METHODS: Patients from the Redo-TAVR registry were analyzed using propensity weighting according to their initial valve type (bTAV [n = 115] vs sTAV [n = 106]) and subsequent valve type (bTAV [n = 130] vs sTAV [n = 91]). RESULTS: Patients with failed bTAVs presented later (vs sTAV) (4.9 ± 2.1 years vs 3.7 ± 2.3 years; P < 0.001), with smaller effective orifice area (1.0 ± 0.7 cm2 vs 1.3 ± 0.8 cm2; P = 0.018) and less frequent dominant regurgitation (16.2% vs 47.3%; P < 0.001). Mortality at 30 days was 2.3% (TAV-in-bTAV) vs 0% (TAV-in-sTAV) (P = 0.499) and 1.7% (bTAV-in-TAV) vs 1.0% (sTAV-in-TAV) (P = 0.612); procedural safety was 72.6% (TAV-in-bTAV) vs 71.2% (TAV-in-sTAV) (P = 0.817) and 73.2% (bTAV-in-TAV) vs 76.5% (sTAV-in-TAV) (P = 0.590). Device success was similar according to initial valve type but higher with subsequent sTAV vs bTAV (77.2% vs 64.3%; P = 0.045), primarily because of lower residual gradients (10.3 mm Hg [8.9-11.7 mm Hg] vs 15.2 mm Hg [13.2-17.1 mm Hg]; P < 0.001). Residual regurgitation (moderate or greater) was similar after bTAV-in-TAV and sTAV-in-TAV (5.7%) and nominally higher after TAV-in-bTAV (9.1%) vs TAV-in-sTAV (4.4%) (P = 0.176). CONCLUSIONS: In selected patients, no association was observed between TAV type and redo TAVR safety or mortality, yet subsequent sTAV was associated with higher device success because of lower redo gradients. These findings are preliminary, and more data are needed to guide valve choice for redo TAVR.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Sistema de Registros , Fatores de Risco , Resultado do Tratamento
3.
J Am Coll Cardiol ; 77(1): 1-14, 2021 01 05.
Artigo em Inglês | MEDLINE | ID: mdl-33413929

RESUMO

BACKGROUND: Surgical aortic valve replacement and transcatheter aortic valve replacement (TAVR) are now both used to treat aortic stenosis in patients in whom life expectancy may exceed valve durability. The choice of initial bioprosthesis should therefore consider the relative safety and efficacy of potential subsequent interventions. OBJECTIVES: The aim of this study was to compare TAVR in failed transcatheter aortic valves (TAVs) versus surgical aortic valves (SAVs). METHODS: Data were collected on 434 TAV-in-TAV and 624 TAV-in-SAV consecutive procedures performed at centers participating in the Redo-TAVR international registry. Propensity score matching was applied, and 330 matched (165:165) patients were analyzed. Principal endpoints were procedural success, procedural safety, and mortality at 30 days and 1 year. RESULTS: For TAV-in-TAV versus TAV-in-SAV, procedural success was observed in 120 (72.7%) versus 103 (62.4%) patients (p = 0.045), driven by a numerically lower frequency of residual high valve gradient (p = 0.095), ectopic valve deployment (p = 0.081), coronary obstruction (p = 0.091), and conversion to open heart surgery (p = 0.082). Procedural safety was achieved in 116 (70.3%) versus 119 (72.1%) patients (p = 0.715). Mortality at 30 days was 5 (3%) after TAV-in-TAV and 7 (4.4%) after TAV-in-SAV (p = 0.570). At 1 year, mortality was 12 (11.9%) and 10 (10.2%), respectively (p = 0.633). Aortic valve area was larger (1.55 ± 0.5 cm2 vs. 1.37 ± 0.5 cm2; p = 0.040), and the mean residual gradient was lower (12.6 ± 5.2 mm Hg vs. 14.9 ± 5.2 mm Hg; p = 0.011) after TAV-in-TAV. The rate of moderate or greater residual aortic regurgitation was similar, but mild aortic regurgitation was more frequent after TAV-in-TAV (p = 0.003). CONCLUSIONS: In propensity score-matched cohorts of TAV-in-TAV versus TAV-in-SAV patients, TAV-in-TAV was associated with higher procedural success and similar procedural safety or mortality.


Assuntos
Estenose da Valva Aórtica/cirurgia , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Injúria Renal Aguda/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/mortalidade , Conversão para Cirurgia Aberta/estatística & dados numéricos , Oclusão Coronária/epidemiologia , Feminino , Hemorragia/epidemiologia , Humanos , Masculino , Marca-Passo Artificial/estatística & dados numéricos , Segurança do Paciente , Pontuação de Propensão , Sistema de Registros
4.
J Am Coll Cardiol ; 75(16): 1882-1893, 2020 04 28.
Artigo em Inglês | MEDLINE | ID: mdl-32327098

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) use is increasing in patients with longer life expectancy, yet robust data on the durability of transcatheter heart valves (THVs) are limited. Redo-TAVR may play a key strategy in treating patients in whom THVs fail. OBJECTIVES: The authors sought to examine outcomes following redo-TAVR. METHODS: The Redo-TAVR registry collected data on consecutive patients who underwent redo-TAVR at 37 centers. Patients were classified as probable TAVR failure or probable THV failure if they presented within or beyond 1 year of their index TAVR, respectively. RESULTS: Among 63,876 TAVR procedures, 212 consecutive redo-TAVR procedures were identified (0.33%): 74 within and 138 beyond 1 year of the initial procedure. For these 2 groups, TAVR-to-redo-TAVR time was 68 (38 to 154) days and 5 (3 to 6) years. The indication for redo-TAVR was THV stenosis in 12 (16.2%) and 51 (37.0%) (p = 0.002) and regurgitation or combined stenosis-regurgitation in 62 (83.8%) and 86 (62.3%) (p = 0.028), respectively. Device success using VARC-2 criteria was achieved in 180 patients (85.1%); most failures were attributable to high residual gradients (14.1%) or regurgitation (8.9%). At 30-day and 1-year follow-up, residual gradients were 12.6 ± 7.5 mm Hg and 12.9 ± 9.0 mm Hg; valve area 1.63 ± 0.61 cm2 and 1.51 ± 0.57 cm2; and regurgitation ≤mild in 91% and 91%, respectively. Peri-procedural complication rates were low (3 stroke [1.4%], 7 valve malposition [3.3%], 2 coronary obstruction [0.9%], 20 new permanent pacemaker [9.6%], no mortality), and symptomatic improvement was substantial. Survival at 30 days was 94.6% and 98.5% (p = 0.101) and 83.6% and 88.3% (p = 0.335) at 1 year for patients presenting with early and late valve dysfunction, respectively. CONCLUSIONS: Redo-TAVR is a relatively safe and effective option for selected patients with valve dysfunction after TAVR. These results are important for applicability of TAVR in patients with long life expectancy in whom THV durability may be a concern.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Complicações Pós-Operatórias , Reoperação , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/epidemiologia , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Análise de Falha de Equipamento , Feminino , Saúde Global , Humanos , Masculino , Avaliação de Resultados em Cuidados de Saúde , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/cirurgia , Sistema de Registros/estatística & dados numéricos , Reoperação/instrumentação , Reoperação/métodos , Reoperação/estatística & dados numéricos , Análise de Sobrevida , Avaliação de Sintomas/estatística & dados numéricos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...