1.
Ultrasound Med Biol ; 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38575416

RESUMO

OBJECTIVE: We have studied the use of polymethyl methacrylate (PMMA) as an alternative biopsy marker that is readily detectable with ultrasound Doppler twinkling in cases of in vitro, ex vivo, or limited duration in vivo settings. This study investigates the long-term safety and ultrasound Doppler twinkling detectability of a PMMA breast biopsy marker following local perturbations and different dwell times in a 6-mo animal experiment. METHODS: This study, which was approved by our Institutional Animal Care and Use Committee, involved three pigs and utilized various markers, including PMMA (Zimmer Biomet), 3D-printed, and Tumark Q markers. Markers were implanted at different times for each pig. Mesh material or ethanol was used to induce a local inflammatory reaction near certain markers. A semiquantitative twinkling score assessed twinkling for actionable localization during monthly ultrasounds. At the primary endpoint, ultrasound-guided localization of lymph nodes with detectable markers was performed. Following surgical resection of the localized nodes, histomorphometric analysis was conducted to evaluate for tissue ingrowth and the formation of a tissue rind around the markers. RESULTS: No adverse events occurred. Twinkling scores of all markers for all three pigs decreased gradually over time. The Q marker exhibited the highest mean twinkling score followed by the PMMA marker, PMMA with mesh, and Q with ethanol. The 3D-printed marker with mesh and PMMA with ethanol had the lowest scores. All wire-localized lymph nodes were successfully resected. Despite varying percentages of tissue rind around the markers and a significant reduction in overall twinkling (p < 0.001) over time, mean PMMA twinkling scores remained clinically actionable at 6 and 5 mo using a General Electric C1-6 probe and 9L-probe, respectively. CONCLUSIONS: In this porcine model, the PMMA marker demonstrates an acceptable safety profile. Clinically actionable twinkling aids PMMA marker detection even after 6 mo of dwell time in porcine lymph nodes. The Q marker maintained the greatest twinkling over time compared to all the other markers studied.

2.
IEEE Trans Biomed Eng ; PP2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38607722

RESUMO

OBJECTIVE: We demonstrate the use of ultrasound to receive an acoustic signal transmitted from a radiological clip designed from a custom circuit. This signal encodes an identification number and is localized and identified wirelessly by the ultrasound imaging system. METHODS: We designed and constructed the test platform with a Teensy 4.0 microcontroller core to detect ultrasonic imaging pulses received by a transducer embedded in a phantom, which acted as the radiological clip. Ultrasound identification (USID) signals were generated and transmitted as a result. The phantom and clip were imaged using an ultrasonic array (Philips L7-4) connected to a Verasonics™ Vantage 128 system operating in pulse inversion (PI) mode. Cross-correlations were performed to localize and identify the code sequences in the PI images. RESULTS: USID signals were detected and visualized on B-mode images of the phantoms with up to sub-millimeter localization accuracy. The average detection rate across 30,400 frames of ultrasound data was 98.1%. CONCLUSION: The USID clip produced identifiable, distinguishable, and localizable signals when imaged. SIGNIFICANCE: Radiological clips are used to mark breast cancer being treated by neoadjuvant chemotherapy (NAC) via implant in or near treated lesions. As NAC progresses, available marking clips can lose visibility in ultrasound, the imaging modality of choice for monitoring NAC-treated lesions. By transmitting an active signal, more accurate and reliable ultrasound localization of these clips could be achieved and multiple clips with different ID values could be imaged in the same field of view.

3.
Med Phys ; 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38629912

RESUMO

BACKGROUND: High dose rate brachytherapy is commonly used in the treatment of prostate cancer. Treatment planning is often performed under transrectal ultrasound (US) guidance, but brachytherapy needles can be challenging to digitize due to the presence of poor US conspicuity and imaging artifacts. The plan accuracy and quality, however, are dependent on the proper visualization of the needles with millimeter accuracy. PURPOSE: This work describes a technique for generating a color overlay of needle locations atop the grayscale US image. Prototype devices were developed to produce vibrations in the brachytherapy needles that generate a high contrast color Doppler (CD) signal that highlights the needle locations with superior contrast and reduced artifacts. Denoted by the acronym color VISION (Vibrationally Induced Shimmering for Identifying an Object's Nature), the technology has the potential to improve applicator conspicuity and facilitate automated applicator digitization. METHODS: Three prototype vibrational devices with frequencies between 200-450 Hz were designed in-house and evaluated with needle implants in a phantom and cadaveric male pelvis using: (1) an actuator attached to the front of a prostate needle template; (2) an actuator attached to the top of the needle template; and (3) a hand-held actuator with a stylet, inserted directly into a needle's inner lumen. Acquired images were postprocessed in MATLAB to evaluate the potential for automated digitization. RESULTS: All prototype devices produced localized shimmering in implanted brachytherapy needles in both the axial and sagittal planes. The template mounted actuators provided better vibrational coupling and ease of operation than the stylet prototype. The Michelson contrast, or visibility, of the shimmering CD signal was 100% compared with ≤40% for B-mode imaging of a single needle. Proof-of-principle for automated applicator digitization using only the CD signal was demonstrated. CONCLUSIONS: The color VISION prototype devices successfully coupled mechanical vibrations into brachytherapy needles to generate US CD shimmering and accurately highlight brachytherapy needle locations. The high contrast and natively registered signal are promising for future work to automate the needle digitization and provide a real-time visual overlay of the applicator on the B-mode US image.

4.
Ultrasound Med Biol ; 50(5): 671-679, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38331697

RESUMO

OBJECTIVE: The color Doppler twinkling artifact has been attributed to existing microbubbles or cavitation occurring on rough objects such as kidney stones, some breast biopsy clips, catheter guidewires and sandpaper. The objective was to investigate the correlation between the surface characteristics of helical constructs with different groove geometries and the occurrence of twinkling, as well as to identify locations conducive to bubble retention and/or cavitation. METHODS: Six half-cylinders were created with a microscale 3-D printer with 5 µm resolution to replicate the geometry of twinkling helical constructs resembling catheter guidewires. Four copies of each marker including a non-twinkling control were printed. The half-cylinders had pitch (peak-to-peak distance) values ranging from 87.5 to 343 µm and amplitude (groove depth) values ranging from 41.5 to 209 µm. The half-cylinders were submerged in degassed water and optically imaged before and after ultrasound insonification to visualize bubbles on the cylinders. The cylinders remained submerged while scanning with the color Doppler mode at frequencies from 3.1 to 6.3 MHz using a GE Logiq E9 scanner and 9L linear array transducer. RESULTS: Two markers exhibited twinkling: one with pitch-to-amplitude ratio of 174/210 µm/µm (0.8) that twinkled only with pre-existing bubbles on the marker; the other had a ratio of 87/87 µm/µm (1.00) that twinkled without pre-existing bubbles on the marker. CONCLUSION: This work provides strong evidence that both existing bubbles and either cavitation or ultrasound wave interactions with patterned or rough surfaces are significant factors in producing the twinkling signature.


Assuntos
Cálculos Renais , Humanos , Cálculos Renais/patologia , Ultrassonografia , Ultrassonografia Doppler em Cores/métodos , Imagens de Fantasmas , Microbolhas , Artefatos
5.
Plast Reconstr Surg Glob Open ; 11(10): e5328, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37842077

RESUMO

Lymphaticovenous anastomosis (LVA) surgery is an effective surgery for the treatment of lymphedema in the extremities. Indocyanine green lymphography is the reference standard for visualizing lymphatics for LVA surgery, but it has several limitations; most notably, superficial dermal congestion can mask deeper lymphatic vessels. To overcome the limitations, we add contrast-enhanced ultrasound (CEUS) lymphography. We have previously reported that CEUS lymphography can identify lymphatic vessels for LVA surgery that indocyanine green lymphography does not. Here, we describe how we perform CEUS lymphography, including workflow, technique, and documentation. Before informed consent, the patient must be screened for possible adverse reactions to microbubbles. The procedure involves multiple intradermal injections of the microbubble agent at various sites along the extremity. After each injection, imaging for microbubble uptake by lymphatic vessels is performed using an ultrasound scanner with contrast-specific software. We use sulfur hexafluoride lipid-type A microspheres (Lumason/SonoVue; Bracco Suisse SA), but we are investigating the performance of other Food & Drug Administration-approved microbubble agents for CEUS lymphography. Having a systematic approach to marking the skin can mitigate the hindrance of marking over ultrasound coupling gel. Another benefit of CEUS lymphography is the rapid identification of neighboring veins compatible in size and location for anastomosis. We hold regular scheduled multidisciplinary meetings for coordination of care, discussion of outcomes, quality assurance, and ongoing innovation.

6.
Med Image Anal ; 90: 102960, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37769552

RESUMO

Multi-task learning (MTL) methods have been extensively employed for joint localization and classification of breast lesions on ultrasound images to assist in cancer diagnosis and personalized treatment. One typical paradigm in MTL is a shared trunk network architecture. However, such a model design may suffer information-sharing conflicts and only achieve suboptimal performance for individual tasks. Additionally, the model relies on fully-supervised learning methodologies, imposing heavy burdens on data annotation. In this study, we propose a novel joint localization and classification model based on attention mechanisms and a sequential semi-supervised learning strategy to address these challenges. Our proposed framework offers three primary advantages. First, a lesion-aware network with multiple attention modules is designed to improve model performance on lesion localization. An attention-based classifier explicitly establishes correlations between the two tasks, alleviating information-sharing conflicts while leveraging location information to assist in classification. Second, a two-stage sequential semi-supervised learning strategy is designed for model training to achieve optimal performance on both tasks and substantially reduces the need for data annotation. Third, the asymmetric and modular model architecture allows for the flexible interchangeability of individual components, rendering the model adaptable to various applications. Experimental results from two different breast ultrasound image datasets under varied conditions have demonstrated the effectiveness of the proposed method. Furthermore, we conduct comprehensive investigations into the impacts of various factors on model performance, gaining in-depth insights into the mechanism of our proposed framework. The code is available at https://github.com/comp-imaging-sci/lanet-bus.git.


Assuntos
Mama , Ultrassonografia Mamária , Humanos , Feminino , Ultrassonografia , Mama/diagnóstico por imagem , Aprendizado de Máquina Supervisionado , Processamento de Imagem Assistida por Computador
7.
Brachytherapy ; 22(6): 761-768, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37652777

RESUMO

PURPOSE: Suboptimal ultrasound conspicuity of the brachytherapy applicator can lead to inaccurate image reconstructions of the applicator resulting in decreased tumor control or increased normal tissue dose. This feasibility study aims to improve ultrasound conspicuity of high-dose rate (HDR) brachytherapy needles by modifying the surface of the needles to produce a color Doppler twinkling signature. MATERIALS AND METHODS: Surface modifications of standard 17-gauge titanium HDR brachytherapy needles included laser-scribing, application of polymethyl methacrylate (PMMA), and coating with a commercially available echogenic coating. Laser-scribing was performed with variable widths (0.1-1 mm) and depths (10-100 µm). The echogenic coating was applied with 3 different thicknesses (27, 40, and 64 µm). Unmodified and modified needles were imaged under B-mode and color Doppler ultrasound in phantom and cadaver, and the signal strength was recorded. RESULTS: Laser-scribed, PMMA-coated, and echogenic-coated brachytherapy needles produced a twinkling signature along the needle shaft on color Doppler ultrasound. Twinkling was observed with laser-scribe depths >20 µm and widths >0.1 mm and from echogenic coatings 40 µm and 64 µm thick. Twinkling was not observed with unmodified needles. The twinkling signature had a spectral composition with a uniform magnitude between the velocities of 2 to 16 cm/s. CONCLUSIONS: Color Doppler ultrasound of surface-modified brachytherapy applicators may improve applicator conspicuity aiding applicator placement and digitization. HDR brachytherapy needles may be modified to produce the twinkling signature via laser-scribing, PMMA rings, or applying an echogenic coating.


Assuntos
Braquiterapia , Masculino , Humanos , Braquiterapia/métodos , Polimetil Metacrilato , Próstata , Ultrassonografia , Agulhas
8.
Radiol Imaging Cancer ; 5(4): e220168, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37326508

RESUMO

Breast biopsy markers play an essential role in the surgical management of patients with clinically node-positive breast cancer. Marking a pathology-proven lymph node ensures accurate imaging assessment of response to neoadjuvant systemic therapy and decreased false-negative rates in sentinel lymph node biopsy. There is a clinically unmet need to make breast biopsy markers, particularly in the axilla, more sonographically visible or identifiable for preoperative localization purposes. Previously described color Doppler US twinkling artifact of some breast biopsy markers in in vitro gel phantoms and in ex vivo cadaveric breasts suggests that twinkling of such markers can be leveraged for improved in vivo detection. In this retrospective case series of eight female patients (mean age, 58.6 years ± 12.3 [SD]), conventional B-mode US imaging failed to identify the biopsy marker associated with a surgical target in the breast or in an axillary lymph node. However, in each patient, the marker was successfully identified with the help of color Doppler US twinkling. Keywords: Breast, Ultrasound, Color Doppler US, Lymphatic, Artifacts, Biopsy Marker Published under a CC BY 4.0 license.


Assuntos
Artefatos , Neoplasias da Mama , Humanos , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Biópsia de Linfonodo Sentinela/métodos , Neoplasias da Mama/diagnóstico por imagem , Linfonodos/diagnóstico por imagem
9.
Med Phys ; 50(3): 1418-1427, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36511174

RESUMO

BACKGROUND: Applicator conspicuity in ultrasound-guided brachytherapy procedures is commonly impaired by imaging artifacts or non-ideal imaging geometry, which can slow down applicator position digitization and increase the geometric uncertainty of the delivered dose distribution. PURPOSE: The purpose of this study was to improve the conspicuity of high-dose rate (HDR) brachytherapy needles under B-mode ultrasound imaging by applying an echogenic surface coating. Our hypothesis was that an echogenic coating would reduce artifacts and improve needle visualization within regions of signal degradation. METHODS: In this study, 17-gauge, 25-cm long titanium HDR brachytherapy needles were coated with acoustically reflective microspheres over a 2.5 cm region starting from the needle tip. Three coating thicknesses (27 µm, 40 µm, 64 µm) were compared against an uncoated control needle. The coated and uncoated needles were imaged using B-mode ultrasound in a tissue-equivalent prostate phantom and in a cadaverous male pelvis using a transrectal probe. Needle conspicuity was assessed under multiple conditions: a single needle implant, an implant with multiple needles between the probe and the needle of interest, and an angled needle implant. All images were assessed qualitatively for needle conspicuity and the presence of artifacts and quantitatively using grey-scale image intensity values. RESULTS: The 64 µm echogenic coating reduced the magnitude of reverberation artifacts by 31 ± 14% and comet tail artifacts by 40%-70%. The echogenic coating also improved needle contrast, measured by the relative differences in signal intensity compared with the adjacent environment, when needles were angled up to 30° with respect to the transducer probe in the cadaver. The improvements in conspicuity and artifact reduction increased with increasing coating thickness. The performance of the needles coated with the 64 µm thickness was qualitatively superior and yielded high-contrast, well-circumscribed signals in the cadaverous male pelvis, even under situations where a needle was acoustically shadowed by multiple other needles. CONCLUSIONS: An echogenic surface coating reduced imaging artifacts and improved needle conspicuity under realistic clinical conditions for ultrasound-based prostate or gynecological brachytherapy. The improved conspicuity has the potential to improve the efficiency of needle placement and the accuracy of needle position digitization during brachytherapy procedures.


Assuntos
Braquiterapia , Neoplasias da Próstata , Masculino , Humanos , Braquiterapia/métodos , Ultrassonografia , Agulhas , Próstata/diagnóstico por imagem , Imagens de Fantasmas , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia
10.
AJR Am J Roentgenol ; 220(3): 358-370, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36043610

RESUMO

BACKGROUND. Targeted axillary lymph node dissection after neoadjuvant systemic therapy (NST) for breast cancer depends on identifying marked metastatic lymph nodes. However, ultrasound visualization of biopsy markers is challenging. OBJECTIVE. The purpose of our study was to identify biopsy markers that show actionable twinkling in cadaveric breast and to assess the association of actionable twinkling with markers' surface roughness. METHODS. Commercial breast biopsy markers were evaluated for twinkling artifact in various experimental conditions relating to scanning medium (solid gel phantom, ultrasound coupling gel, cadaveric breast), transducer (ML6-15, 9L, C1-6), and embedding material (present vs absent). Markers were assigned twinkling scores from 0 (confident in no twinkling) to 4 (confident in exuberant twinkling); a score of 3 or greater represented actionable twinkling (sufficient confidence to rely solely on twinkling for target localization). Markers were hierarchically advanced to evaluation with increasingly complex media if showing at least minimal twinkling for a given medium. A 3D coherence optical profiler measured marker surface roughness. Mixed-effects proportional odds regression models assessed associations between twinkling scores and transducer and embedding material; Wilcoxon rank sum test evaluated associations between actionable twinkling and surface roughness. RESULTS. Thirty-five markers (21 with embedding material) were evaluated. Ten markers without embedding material advanced to evaluation in cadaveric breast. Higher twinkling scores were associated with presence of embedding material (odds ratio [OR] = 5.05 in solid gel phantom, 9.84 in coupling gel) and transducer (using the C1-6 transducer as reference; 9L transducer: OR = 0.36, 0.83, and 0.04 in solid gel phantom, ultrasound coupling gel, and cadaveric breast; ML6-15 transducer: OR = 0.07, 0.18, and 0.00 respectively; post hoc p between 9L and ML6-15: p < .001, p = .02, and p = .04). In cadaveric breast, three markers (Cork, Professional Q, MRI [Flex]) exhibited actionable twinkling for two or more transducers; surface roughness was significantly higher for markers with than without actionable twinkling for C1-6 (median values: 0.97 vs 0.35, p = .02) and 9L (1.75 vs 0.36; p = .002) transducers. CONCLUSION. Certain breast biopsy markers exhibited actionable twinkling in cadaveric breast. Twinkling was observed with greater confidence for the C1-6 and 9L transducers than the ML6-15 transducer. Actionable twinkling was associated with higher marker surface roughness. CLINICAL IMPACT. Use of twinkling for marker detection could impact preoperative or intraoperative localization after NST.


Assuntos
Neoplasias da Mama , Ultrassonografia Doppler em Cores , Humanos , Feminino , Ultrassonografia Doppler em Cores/métodos , Ultrassonografia , Imagens de Fantasmas , Artefatos , Cadáver , Biópsia
11.
Radiol Imaging Cancer ; 4(6): e220053, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36367449

RESUMO

Purpose To evaluate the short-term safety of a nonmetallic twinkle marker and compare its conspicuity at color Doppler US with that of standard breast biopsy clips and radioactive seeds by using B-mode US in axillary lymph nodes. Materials and Methods This prospective study (November 2020-July 2021) of participants with node-positive breast cancer who completed chemotherapy involved placing a twinkle marker at the time of preoperative radioactive seed localization. A five-point scoring system (1 = easiest, 5 = most difficult) was used to rate the ease of identifying the clip, seed, and twinkle marker on postlocalization sonograms, mammograms, specimen radiographs, and gross pathologic specimens. Descriptive statistics were used. Results Eight women (mean age, 57 years ± 16 [SD]) were enrolled. The median scores for US conspicuity of each device were 3.9 (range, 3.7-5.0) for the radioactive seed, 2.4 (range, 1.0-5.0) for the clip, and 2.0 (range, 1.0-4.3) for the twinkle marker. In six of eight participants, the twinkle marker was the most identifiable at US. The seeds, clips, and twinkle markers were scored "very easy" to identify on seven of eight postlocalization mammograms. The surgeon retrieved all eight twinkle markers 1-3 days after localization. In all 16 interpretations, the seeds, clips, and twinkle markers were rated as very easy to identify on specimen radiographs. The clip was the most difficult device to identify at pathologic examination in all participants, and the twinkle marker was the easiest to identify in seven of eight participants. Conclusion This pilot study demonstrates that the safety and ease of US detection of a twinkling tissue marker may be comparable to a biopsy clip. Keywords: Ultrasonography, US-Doppler, Breast, Localization, Surgery Clinical trial registration no. NCT04674852 © RSNA, 2022.


Assuntos
Neoplasias da Mama , Feminino , Humanos , Pessoa de Meia-Idade , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Neoplasias da Mama/tratamento farmacológico , Projetos Piloto , Terapia Neoadjuvante , Estudos Prospectivos , Axila/patologia
12.
Australas J Ultrasound Med ; 25(2): 54-65, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35722051

RESUMO

There are very few true breast emergencies. While infrequent, women do present to emergency departments or urgent care centres with breast-related concerns. In this case-based review, both common and uncommon urgent and emergent breast lesions are presented, emphasising ultrasound characteristics and imaging optimisation to improve accurate diagnosis and appropriate recommendations.

13.
Eur Radiol Exp ; 6(1): 26, 2022 06 17.
Artigo em Inglês | MEDLINE | ID: mdl-35711010

RESUMO

Since its first description 25 years ago, color Doppler twinkling has been a compelling ultrasound feature in diagnosing urinary stones. While the fundamental cause of twinkling remains elusive, the distinctive twinkling signature is diagnostically valuable in clinical practice. It can be inferred that if an entity twinkles, it empirically has certain physical features. This work investigates a manipulable polymeric material, polymethyl methacrylate (PMMA), which twinkles and has measurable surface roughness and porosity that likely contribute to twinkling. Comparative investigation of these structural properties and of the twinkling signatures of breast biopsy markers made from PMMA and selected commercially available markers showed how twinkling can improve ultrasound detection of devices intentionally designed to twinkle. While this specific application of detecting breast biopsy markers by twinkling may provide a way to approach an unmet need in the care of patients with breast cancer, this work ultimately provides a platform from which the keys to unlocking the fundamental physics of twinkling can be rigorously explored.


Assuntos
Artefatos , Cálculos Renais , Biópsia , Humanos , Cálculos Renais/patologia , Polimetil Metacrilato , Ultrassonografia Doppler em Cores
14.
Radiology ; 304(1): 218-224, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35380494

RESUMO

Background Lymphaticovenous anastomosis (LVA) surgery is an effective surgical treatment of secondary lymphedema in the extremities, but indocyanine green (ICG) fluorescent lymphography, the reference standard for imaging target lymphatic vessels, has several limitations. More effective methods are needed for preoperative planning. Purpose To evaluate whether contrast-enhanced US (CEUS) can be used to identify target lymphatic vessels for LVA surgery in patients with secondary upper extremity lymphedema and compare the results with those from ICG fluorescent lymphography. Materials and Methods In this single-center retrospective review, CEUS with intradermal injection of microbubbles was performed in patients before LVA surgery in the upper extremities between October 2019 and September 2021. All patients had secondary upper extremity lymphedema from breast cancer treatment. Technical success rate was defined as lymphatic vessels identified with use of CEUS that led to successful LVAs. Descriptive statistics were used. Results All 11 patients were women (mean age, 56 years ± 8 [SD]). The median number of microbubble injection sites was 11 (range, 8-14). CEUS helped identify lymphatic vessels in all 11 women, including in six women in whom ICG fluorescent lymphography could not be performed or failed to help identify any targets. Thirty-five explorations (median, three per patient; range, two to four) were performed, and 24 LVAs (median, three per patient; range, zero to four) were created. Of the anastomoses, 33% (eight of 24) were mapped with use of both CEUS and ICG fluorescent lymphography, 58% (14 of 24) with CEUS only, and 8% (two of 24) with ICG fluorescent lymphography only. Among the 33 explorations on targets mapped with CEUS, an anastomosis could be made at 22 sites, for a technical success rate of 67%. Seven women had at least one additional LVA created from the use of CEUS. Conclusion Contrast-enhanced US is a promising tool for identifying lymphatic vessels in the upper extremities, especially when indocyanine green fluorescent lymphography fails to depict targets or cannot be used. Published under a CC BY 4.0 license.


Assuntos
Vasos Linfáticos , Linfedema , Anastomose Cirúrgica/métodos , Corantes , Feminino , Humanos , Verde de Indocianina , Vasos Linfáticos/diagnóstico por imagem , Vasos Linfáticos/cirurgia , Linfedema/diagnóstico por imagem , Linfedema/cirurgia , Linfografia/métodos , Masculino , Microbolhas , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X
15.
Ultrasound Med Biol ; 47(11): 3122-3134, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34412903

RESUMO

In breast radiology, ultrasound detection of biopsy markers or clips for localization purposes is often challenging, especially in the axilla. The purpose of this research was to test the hypothesis that the surface roughness of biopsy clips would elicit a twinkling signature on color Doppler, making them more readily identifiable by ultrasound. Ultrasound color Doppler imaging of 12 biopsy markers was performed and consensus scoring of the degree of twinkling (0 [no twinkling] to 4 [exuberant twinkling]) was obtained for each of the markers. The surface roughness characteristics of the markers were measured using 3-D coherence scanning interferometry. The 3 markers scoring at least 3 for twinkling in vitro were cork, Q and Vision. Of these 3 markers, only the cork marker scored a 4 ex vivo and in cadaveric tissue. Surface roughness metrics demonstrated a positive estimated correlation with the twinkling scores (rho = 0.33, 95% CI = [-0.48 to 0.84]). Of the 12 markers tested, the markers that twinkled corresponded to surface roughness measured with non-contact 3-D optical imaging. Qualitatively, lower color scales and color frequencies optimized twinkling, but the most specific qualitative predictor of confidence in twinkling was insensitivity to changes in color scale and color frequency values.


Assuntos
Artefatos , Ultrassonografia Doppler em Cores , Axila , Biópsia , Humanos , Ultrassonografia
17.
Clin Imaging ; 72: 198-203, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33486301

RESUMO

Hydrodissection is a procedural tactic utilized in various interventions. It is a technique which helps separate structures in order to safely perform a certain procedure. This article will provide a review of hydrodissection, how to perform this technique, and why it can be useful in breast interventions.


Assuntos
Neoplasias da Mama , Ultrassonografia de Intervenção , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Humanos , Ultrassonografia
18.
J Ultrasound Med ; 40(7): 1427-1443, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32997819

RESUMO

Ultrasound-guided breast biopsies can be challenging to perform, especially when the target is adjacent to the nipple, skin, or implant or when the target is small and in very posterior, dense fibroglandular tissue. Oftentimes, a slightly modified approach can result in a diagnostic biopsy specimen with minimal complications. After a brief review of basic techniques for ultrasound-guided breast biopsies that includes a review of conventional breast biopsy devices, a presentation of procedural modifications and techniques to consider for more challenging cases is described. In particular, novel open-trough and tandem-needle techniques are detailed. Several cases using these techniques are then presented.


Assuntos
Neoplasias da Mama , Biópsia Guiada por Imagem , Mama/diagnóstico por imagem , Feminino , Humanos , Ultrassonografia , Ultrassonografia de Intervenção , Ultrassonografia Mamária
19.
J Breast Imaging ; 3(1): 93-97, 2021 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-38424833

RESUMO

Buffered lidocaine is a local anesthetic option during percutaneous needle-directed procedures in the breast. At our institution, sodium bicarbonate (the buffer) is dispensed in volumes that frequently lead to medical waste and shortages. In this study, we describe how moving the buffering of lidocaine from the procedure room to our clinical hospital pharmacy results in a reduction in costs and improves satisfaction across the breast radiology department. While cost savings are difficult to tease out in practices that opt for bundled payments, we were able to access pricing and supply data and coordinate with our pharmacy to change our practice. Making these changes saves our practice $26 000 a year and allows us to continue to offer buffered lidocaine even during sodium bicarbonate shortages. This manuscript describes how these changes came about and their economic impact.

20.
Plast Reconstr Surg Glob Open ; 8(4): e2805, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32440457

RESUMO

Most magnetic resonance lymphangiography techniques employ intravenous gadolinium-based contrast agents, which carry a US Food and Drug Administration warning about gadolinium retention in the body when used intravenously. Because of this, there may be reluctance to perform intradermal injections of gadolinium-based contrast agents in patients with obstructed lymphatic drainage due to concerns about gadolinium retention in the skin and soft tissues and potential-related toxicity. The aim of this study was to show proof of concept of 2 preoperative lymphangiographic techniques that do not use gadolinium-based contrast agents. One technique used contrast-enhanced ultrasound with intradermal injections of microbubbles (Lumason) in a patient with stage 3, nonpitting left upper extremity edema. Another technique used magnetic resonance imaging with intradermal injections of 0.03 mg/mL or 0.003% ferumoxytol (Feraheme) in a patient with stage 3, nonpitting right lower extremity edema. Both contrast-enhanced ultrasound with microbubbles and magnetic resonance lymphangiogram with ferumoxytol were able to identify candidates for lymphovenous bypass surgery. These candidates were not identified by conventional indocyanine green injections. The authors conclude that (1) low-dose ferumoxytol is a potentially effective non-gadolinium-based contrast alternative to gadolinium-based contrast agent in magnetic resonance lymphangiography and (2) contrast-enhanced ultrasound can identify candidate lymphatic vessels for anastomosis.