Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sleep Breath ; 27(6): 2351-2359, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37211583

RESUMO

PURPOSE: CPAP is the "gold standard" treatment for obstructive sleep apnea (OSA). Current CPAP models have developed additional functions including automatic CPAP and pressure relief. However, CPAP adherence has not improved over the last three decades. Many patients in low-income countries cannot afford these CPAP devices. A novel simple CPAP device with a fixed pressure without pressure controller was developed. METHODS: Manual CPAP pressure titration was performed in 127 patients with OSA. Six patients with a titration pressure higher than 11 cmH2O and 14 patients who could not tolerate CPAP were excluded, leaving 107 participating in the following 2 studies. In study one, 54 of 107 patients were treated by both conventional fixed CPAP and simple CPAP in random order. In the second study, another 53 patients were treated by both autoCPAP in automatic function and simple CPAP in random order. Simple CPAP was fixed at 10 cmH2O, 8 cmH2O, and 6 cmH2O for patients whose titration pressure was between 9-10, 7-8, and ≤ 6 cmH2O, respectively. Conventional fixed CPAP device was set exactly the same as manual titration pressure. RESULTS: All patients whose manual titration pressure ≤ 10 cmH2O were effectively treated by simple CPAP (AHI 40.7 ± 2.3 events/h before vs 2.5 ± 0.3 events/h after, p < 0.001). Patients expressed similar preferences for simple CPAP, autoCPAP, and conventional fixed CPAP (p > 0.05). CONCLUSIONS: We conclude that a novel simple CPAP is an alternative treatment for most patients with OSA, which may widen access to CPAP therapy in the developing countries because of its low cost.


Assuntos
Apneia Obstrutiva do Sono , Humanos , Polissonografia , Apneia Obstrutiva do Sono/terapia , Pressão Positiva Contínua nas Vias Aéreas
2.
Respir Physiol Neurobiol ; 291: 103692, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34020067

RESUMO

BACKGROUND: A fall of ≥ 20 % in forced expiratory volume in the first second (FEV1) with a cumulative dose of histamine ≤ 7.8 µmol is considered to indicate bronchial hyperactivity, but no method exists for patients who cannot perform spirometry properly. Here we hypothesized that increases in respiratory central output measured by chest wall electromyography of the diaphragm (EMGdi-c) expressed as a function of tidal volume (EMGdi-c/VT) would have discriminative power to detect a 'positive' challenge test. METHODS: In a physiological study EMGdi was recorded from esophageal electrode (EMGdi-e) in 16 asthma patients and 16 healthy subjects during a histamine challenge test. In a second study, EMGdi from chest wall surface electrodes (EMGdi-c) was measured during a histamine challenge in 44 asthma patients and 51 healthy subjects. VT was recorded from a digital flowmeter during both studies. RESULTS: With histamine challenge test the change in EMGdi-e/VT in patients with asthma was significantly higher than that in healthy subjects (104.2 % ± 48.6 % vs 0.03 % ± 17.1 %, p < 0.001). Similarly there was a significant difference in the change of EMGdi-c/VT between patients with asthma and healthy subjects (90.5 % ± 75.5 % vs 2.4 % ± 21.7 %, p < 0.001). At the optimal cut-off point (29 % increase in EMGdi-c/VT), the area under the ROC curve (AUC) for detection of a positive test was 0.91 (p < 0.001) with sensitivity 86 % and specificity 92 %. CONCLUSIONS: We conclude that EMGdi-c/VT may be used as an alternative for the assessment of bronchial hypersensitivity and airway reversibility to differentiate patients with asthma from healthy subjects.


Assuntos
Asma/diagnóstico , Hiper-Reatividade Brônquica/diagnóstico , Broncoconstrição/fisiologia , Broncodilatadores/farmacologia , Diafragma/fisiopatologia , Histamina/farmacologia , Volume de Ventilação Pulmonar/fisiologia , Adolescente , Adulto , Idoso , Broncoconstrição/efeitos dos fármacos , Broncodilatadores/administração & dosagem , Eletromiografia , Feminino , Histamina/administração & dosagem , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
3.
J Appl Physiol (1985) ; 128(3): 586-595, 2020 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-31944886

RESUMO

Approximately 20% of chronic obstructive pulmonary disease (COPD) patients have been considered to have a "nonhyperinflator phenotype." However, this judgment depends on patients making a fully maximal inspiratory capacity (IC) maneuver at rest, since the IC during exercise is compared with this baseline measurement. We hypothesized that IC maneuvers at rest are sometimes submaximal and tested this hypothesis by measuring IC and associated neural respiratory drive at rest and during inhalation of CO2 and exercise in patients with COPD. Twenty-six COPD patients [age 66 ± 6 yr, mean forced expiratory volume in 1 s (FEV1) 40 ± 11% predicted] and 39 healthy subjects (age 39 ± 14 yr, FEV1 98 ± 12% predicted) were studied. IC and the diaphragm electromyogram (EMGdi) associated with it (EMGdi-IC) and forced inspiratory vital capacity (FIVC) and its corresponding EMGdi (EMGdi-FIVC) were measured during inhalation of 8% CO2 (8% CO2-92% O2) and room air. Incremental exhaustive cycle ergometer exercise was also performed in both patients with COPD and healthy subjects. IC, EMGdi-IC, FIVC, and EMGdi-FIVC during breathing 8% CO2 were significantly greater than those during breathing room air in both patients with COPD and healthy subjects (all P < 0.001). EMGdi-IC in patients with COPD constantly increased during exercise from 145 ± 40 µV at rest to 185 ± 52 µV at the end of exercise but change in IC was variable. Neural respiratory drive and its relevant IC increased during hypercapnia. Exercise-related hypercapnia in patients with COPD raises neural respiratory drives, which compensate for IC reduction, leading to underestimation of dynamic hyperinflation measured by IC at rest breathing room air.NEW & NOTEWORTHY Inspiratory capacity measured during hypercapnia is higher than that during eucapnia. Thus total lung capacity is not always be achieved by a standard inspiratory capacity maneuver, leading to risk of underestimation of dynamic hyperinflation in patients with severe chronic obstructive pulmonary disease after exhaustive exercise.


Assuntos
Doença Pulmonar Obstrutiva Crônica , Adulto , Idoso , Teste de Esforço , Volume Expiratório Forçado , Humanos , Capacidade Inspiratória , Pessoa de Meia-Idade , Fenótipo , Testes de Função Respiratória
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...