Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 96
Filtrar
1.
Anal Methods ; 16(19): 3125-3130, 2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38700061

RESUMO

A new fluorescence sensing approach has been proposed for the precise determination of the anti-cancer drug oxaliplatin (Oxal-Pt). This method entails synthesizing blue-emitting copper nanoclusters (CuNCs) functionalized with bovine serum albumin (BSA) as the stabilizing agent. Upon excitation at 360 nm, the resultant probe exhibits emission at 460 nm. Notably, the fluorescence response of BSA@CuNCs substantially increases upon incubation with Oxal-Pt due to multiple binding interactions between the drug and the fluorescent probe. These interactions involve hydrogen bonding, hydrophobic interaction, and the high affinity between the SH groups (cysteine residues of BSA) and platinum (in Oxal-Pt). Consequently, this interaction induces aggregation-induced emission enhancement (AIEE) of BSA@CuNCs. The probe demonstrates a broad response range from 0.08 to 140.0 µM, along with a low detection limit of 20.0 nM, determined based on a signal-to-noise ratio of 3. Furthermore, the probe effectively detects Oxal-Pt in injections, human serum, and urine samples, yielding acceptable results. This study represents a significant advancement in the development of a straightforward and efficient sensor for monitoring platinum-containing anti-cancer drugs during chemotherapy.


Assuntos
Antineoplásicos , Cobre , Monitoramento de Medicamentos , Corantes Fluorescentes , Oxaliplatina , Soroalbumina Bovina , Espectrometria de Fluorescência , Oxaliplatina/química , Soroalbumina Bovina/química , Cobre/química , Humanos , Antineoplásicos/química , Monitoramento de Medicamentos/métodos , Espectrometria de Fluorescência/métodos , Corantes Fluorescentes/química , Nanopartículas Metálicas/química , Animais , Limite de Detecção , Neoplasias/tratamento farmacológico , Bovinos
2.
Anal Methods ; 16(20): 3287-3296, 2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38738631

RESUMO

This study introduces a novel approach for the simultaneous determination of topotecan (TOP) and pantoprazole (PNT), two drugs whose interaction is critical in clinical applications. The significance of this study originates from the need to understand the pharmacokinetic changes of TOP after PNT administration, which can inform necessary dose adjustments of TOP. To achieve this, nitrogen blue emissive carbon dots (B@NCDs) were produced and employed due to their unique fluorescent properties. When TOP is added to B@NCDs, it exhibits strong native fluorescence at 545 nm without influencing the B@NCDs' fluorescence at 447 nm. Conversely, PNT causes quenching of B@NCDs fluorescence, a property that enables the distinct detection of both drugs. The B@NCDs were fully characterized using different techniques, including ultraviolet-visible spectrophotometry, fluorescence analysis, X-ray diffraction (XRD), transmission electron microscopy (TEM), and FTIR spectroscopy. The proposed method demonstrated excellent linearity, selectivity, and sensitivity, with low detection limits (LOD, S/N = 3); 0.0016 µg mL-1 for TOP and 0.36 µg mL-1 for PNT. Applied to spiked rabbit plasma samples, this method offers a new approach for evaluating the pharmacokinetic interaction between TOP and PNT. It enables the determination of all pharmacokinetic parameters of TOP before and after coadministration with PNT, providing essential insights into whether dose adjustments are necessary. This research not only contributes to the field of drug monitoring and interaction studies but also exemplifies the potential of B@NCDs in complex biological matrices, paving the way for further pharmacological and therapeutic applications.


Assuntos
Carbono , Pantoprazol , Pontos Quânticos , Topotecan , Pantoprazol/farmacocinética , Pantoprazol/química , Topotecan/farmacocinética , Topotecan/química , Topotecan/análise , Carbono/química , Pontos Quânticos/química , Espectrometria de Fluorescência/métodos , Animais , Limite de Detecção , Corantes Fluorescentes/química
3.
J Fluoresc ; 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38691279

RESUMO

A novel ratiometric fluorescence probe was developed for the determination of azithromycin (AZM) and sulfide ions based on the differential modulation of red emissive carbon dots (R-N@CDs) and blue emissive carbon dots (B-NS@CDs). The addition of sulfide anion selectively quenched the red emission of R-N@CDs while the blue emission of B-NS@CDs unaffected. Upon subsequent introduction of AZM to this R-N@CDs@sulfide system, the quenched red fluorescence was restored. Comprehensive characterization of the CDs was performed using UV-Vis, fluorescence, FTIR spectroscopy, XPS, and TEM. The proposed method exhibited excellent sensitivity and selectivity, with limits of detection of 0.33 µM for AZM and 0.21 µM for sulfide. Notably, this approach enabled direct detection of sulfide without requiring prior modulation of the CDs with metal ions, as is common in other reported methods. The ratiometric probe was successfully applied for the determination of AZM in biological fluids and sulfide in environmental water samples with high selectivity. This work presents the first fluorometric method for the detection of AZM in biological fluids.

4.
Anal Methods ; 16(12): 1804-1810, 2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38436376

RESUMO

In this study, we present a thoughtful integration of a dispersive solid-phase sorbent and oxine for the ultrasensitive and highly selective determination of Al3+ ions. Cobalt ferrite nanoparticles (CoFe2O4 NPs) modified with oxine were employed to facilitate the pre-concentration and estimation of Al3+, forming highly fluorescent chelate. The modification process included the assistance of sodium dodecyl sulfate (SDS) and sonication. The results indicated that the fluorescence intensity of Al3+-oxine/SDS@CoFe2O4 NPs surpassed that of Al3+-oxine alone. The confirmation of the successful functionalization of CoFe2O4 NPs with oxine was established through various techniques. Under optimal conditions, the fluorescence intensity exhibited a positive correlation with increasing concentrations of Al3+ within the range of 0.029-600 ng mL-1, achieving a detection limit of 0.0087 ng mL-1 based on signal to noise ratio 3 : 1. The developed method was effectively applied to the determination of Al3+ in drinking water samples, yielding recoveries in the range of 97.19% to 103.13%, with a relative standard deviation (RSD%) not exceeding 3.78%.

5.
Mikrochim Acta ; 191(3): 123, 2024 02 07.
Artigo em Inglês | MEDLINE | ID: mdl-38324133

RESUMO

A novel electrochemical sensor with a dual-template molecular imprinting technology was fabricated for the simultaneous detection of paracetamol (PAR) and isoniazid (INZ). The sensor was constructed using nitrogen and sulfur co-doped molybdenum carbide (N, S@Mo2C) and a thin layer of electro-polymerized methylene blue was applied onto the surface of the N, S@Mo2C. The electrochemical sensor demonstrated remarkable analytical efficiency for the concurrent PAR and INZ quantification under optimal circumstances. The system achieved an exceptionally low limit of detection (S/N = 3) of  3.7 nM for PAR, with a concentration range  of  0.013 and 140 µM.  A LOD of 7.6 nM was attained for INZ, with a linear range  between 0.025 and 140 µM. Furthermore, the platform's selectivity was evaluated using differential pulse voltammetry  (DPV). The designed platform successfully detected PAR and INZ in authentic samples with recoveries varying between 98.3% and 104.9%. The relative standard deviations (RSD) for these measurements ranged from 2.7 to 4.0%, demonstrating that the proposed sensor is extremely stable, repeatable, and reproducible. These promising results suggest that the sensor holds potential for the detection of various (bio) molecules, paving the way for future applications in sensing fields.


Assuntos
Acetaminofen , Azul de Metileno , Molibdênio , Isoniazida , Nitrogênio , Enxofre
6.
RSC Adv ; 14(8): 5406-5416, 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38348296

RESUMO

In the present study, nanoceria-decorated MWCNTs (CeNPs@MWCNTs) were synthesized using a simple and inexpensive process. Molnupiravir (MPV) has gained considerable attention in recent years due to the infection of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2). Since some people infected with COVID-19 experience fever and headaches, paracetamol (PCM) has been prescribed to relieve these symptoms. Therefore, there is an urgent need to monitor and detect these drugs simultaneously in pharmaceutical and biological samples. In this regard, we developed a novel sensor based on nanoceria-loaded MWCNTs (CeNPs@MWCNTs) for simultaneous monitoring of MPV and PCM. The incorporation of CeNPs@MWCNTs electrocatalyst into a glassy carbon microsphere fluorolube oil paste electrode (GCMFE) creates more active sites, which increase the surface area, electrocatalytic ability, and electron transfer efficiency. Interestingly, CeNPs@MWCNTs modified GCMFE demonstrated excellent detection limits (6.0 nM, 8.6 nM), linear ranges (5.0-5120 nM, 8.0-4162 nM), and sensitivities (78.6, 94.3 µA µM-1 cm-2) for simultaneous detection of MPV and PCM. The developed CeNPs@MWCNTs electrocatalyst modified GCMFE exhibited good repeatability, anti-interference capability, stability, and real-time analysis with good recovery results, which clearly indicates that it can be used for real-time industrial applications.

7.
J Glaucoma ; 33(5): 334-339, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38194297

RESUMO

PRCIS: Corneal hysteresis (CH) and pulsatile ocular blood volume (POBV) were significantly lower in the eye with greater damage in asymmetric glaucoma, without a difference in intraocular pressure (IOP) or central corneal thickness (CCT), and no difference in elastic parameters. OBJECTIVE: To compare biomechanical and vascular metrics between the eyes of patients with asymmetric glaucoma (ASYMM) and those with symmetric glaucoma (SYMM). PATIENTS AND METHODS: Forty-five patients were prospectively recruited and divided into ASYMM, defined as cup-to-disc (C/D) ratio difference >0.1 between eyes and SYMM, with C/D difference ≤0.1. For ASYMM, the smaller C/D was defined as the best eye ("best") and the fellow eye was defined as the worst eye ("worse"). All metrics were subtracted as "worse" minus "best," including the viscoelastic parameter CH, and elastic parameters from the Corvis ST, including stiffness parameter at first applanation, stiffness parameter at highest concavity, integrated inverse radius, deformation amplitude ratio, IOP, CCT, mean deviation (MD), ganglion cell complex (GCC), and POBV were included. Paired t tests were performed between eyes in both groups. Statistical analyses were performed with SAS using a significance threshold of P <0.05. RESULTS: For ASYMM (16 patients), "worse" showed significantly lower CH (-0.76 ± 1.22), POBV (-0.38 ± 0.305), MD (-3.66 ± 6.55), and GCC (-7.9 ± 12.2) compared with "best." No other parameters were significantly different. For SYMM (29 patients), there were no significantly different metrics between eyes. CONCLUSIONS: Lower CH, POBV, GCC, and worse MD were associated with greater glaucomatous damage in asymmetric glaucoma without a difference in IOP or CCT. Lower CH and GCC are consistent with previous studies. POBV, a new clinical parameter that may indicate reduced blood flow, is also associated with greater damage.


Assuntos
Córnea , Pressão Intraocular , Tonometria Ocular , Campos Visuais , Humanos , Pressão Intraocular/fisiologia , Feminino , Masculino , Estudos Prospectivos , Pessoa de Meia-Idade , Fenômenos Biomecânicos , Córnea/fisiopatologia , Idoso , Campos Visuais/fisiologia , Células Ganglionares da Retina/patologia , Elasticidade/fisiologia , Disco Óptico/irrigação sanguínea , Glaucoma de Ângulo Aberto/fisiopatologia , Glaucoma de Ângulo Aberto/diagnóstico , Glaucoma/fisiopatologia , Fibras Nervosas/patologia , Doenças do Nervo Óptico/fisiopatologia , Doenças do Nervo Óptico/diagnóstico
8.
Eye Vis (Lond) ; 11(1): 2, 2024 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-38167119

RESUMO

BACKGROUND: Keratoconus is characterized by asymmetry in the biomechanical properties of the cornea, with focal weakness in the area of cone formation. We tested the hypothesis that centrally-measured biomechanical parameters differ between corneas with peripheral cones and corneas with central cones. METHODS: Fifty participants with keratoconus were prospectively recruited. The mean ± standard deviation age was 38 ± 13 years. Axial and tangential corneal topography were analyzed in both eyes, if eligible. Cones in the central 3 mm of the cornea were considered central, and cones outside the central 3 mm were considered peripheral. Each eye was then measured with the Ocular Response Analyzer (ORA) tonometer. T-tests compared differences in ORA-generated waveform parameters between cohorts. RESULTS: Seventy-eight eyes were analyzed. According to the axial topography maps, 37 eyes had central cones and 41 eyes had peripheral cones. According to the tangential topography maps, 53 eyes had central cones, and 25 eyes had peripheral cones. For the axial-topography algorithm, wave score (WS) was significantly higher in peripheral cones than central cones (inter-cohort difference = 1.27 ± 1.87). Peripheral cones had a significantly higher area of first peak, p1area (1047 ± 1346), area of second peak, p2area (1130 ± 1478), height of first peak, h1 (102 ± 147), and height of second peak, h2 (102 ± 127), than central cones. Corneal hysteresis (CH), width of the first peak, w1, and width of the second peak, w2, did not significantly differ between cohorts. There were similar results for the tangential-topography algorithm, with a significant difference between the cohorts for p1area (855 ± 1389), p2area (860 ± 1531), h1 (81.7 ± 151), and h2 (92.1 ± 131). CONCLUSIONS: Cone location affects the biomechanical response parameters measured under central loading of the cornea. The ORA delivers its air puff to the central cornea, so the fact that h1 and h2 and that p1area and p2area were smaller in the central cone cohort than in the peripheral cone cohort suggests that corneas with central cones are softer or more compliant centrally than corneas with peripheral cones, which is consistent with the location of the pathology. This result is evidence that corneal weakening in keratoconus is focal in nature and is consistent with localized disruption of lamellar orientation.

9.
Spectrochim Acta A Mol Biomol Spectrosc ; 310: 123850, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38219614

RESUMO

In this study, a novel composite material was developed for the ratiometric detection of pyrophosphate anion (P2O74-). This composite consisted of Al and nitrogen co-doped carbon dots (Al-N@CQDs) and glutathione-capped copper nanoclusters (GSH@CuNCs). The Al-N@CQDs component, with its high reserved coordination capacity of Al3+, induced the non-luminescent behavior of GSH@CuNCs, resulting in an aggregation-induced emission (AIE) effect. The hybrid material (Al-N@CQDs/GSH@CuNCs) exhibited dual-emission signals at 620 nm and 450 nm after integrating the two independent materials utilizing the AIE effect and the fluorescence resonance energy transfer (FRET) approach. This approach represents the first utilization of this composite for ratiometric detection. Nevertheless, upon the addition of P2O74-, the AIE and FRET processes were hindered due to the higher coordination interaction of Al3+ towards P2O74- compared to the amino/carboxyl groups on Al-N@CQDs. This successful interference of the AIE and FRET processes allowed for the effective estimation of P2O74-. The response ratio (F450/F620) increased with increasing the concentration of P2O74- in the range of 0.035-160 µM, with an impressive detection limit of 0.012 µM. This innovative approach of utilizing hybrid CQDs/thiolate-capped nanoclusters as a ratiometric fluorescent sensor for analytical applications introduces new possibilities in the field. The as-fabricated system was successfully applied to detect P2O74- in different real samples such as water, serum, and urine samples with acceptable results.

10.
Ophthalmol Sci ; 4(2): 100373, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37868791

RESUMO

Purpose: To introduce the novel parameter of Corneal Contribution to Stress (CCS) and compare stress distribution patterns between keratoconus (KCN) and normal corneas. Design: Prospective, observational, cross-sectional study. Participants: The study included 66 eyes of 40 subjects diagnosed with KCN and 155 left eyes from 155 normal control (NRL) subjects. Methods: Tomography was obtained to calculate the newly proposed CCS, defined according to the hoop stress formula without intraocular pressure, R/2t, where R is the radius of curvature and t is the thickness. CCS maps were calculated from pachymetry and tangential curvature maps. Custom software identified the 2-mm-diameter zones of greatest curvature (Cspot-max), thinnest pachymetry (Pach-min), greatest stress (CCSmax), and lowest stress (CCSmin). Stress difference (CCSdiff) was calculated as CCSmax - CCSmin. Distances between Cspot-max vs. Pach-min, vs. CCSmax, and vs. CCSmin, as well as between Pach-min vs. CCSmax and vs. CCSmin, were calculated. t tests were performed between cohorts, and paired t tests were performed within cohorts. Univariate linear regression analyses were performed between parameters and distances. The significance threshold was P < 0.05. Main Outcome Measures: Corneal stress parameters, corneal features of maximum curvature, minimum thickness, and distances between corneal stress parameters and corneal features. Results: CCSmax was significantly closer to Pach-min (0.79 ± 0.92) and Cspot-max (2.04 ± 0.85) than CCSmin (3.17 ± 0.38, 2.73 ± 1.53, respectively) in NRL, P < 0.0001, whereas CCSmin was significantly closer to Cspot-max (1.35 ± 1.43) than CCSmax (2.52 ± 0.72) in KCN, P < 0.0001. Cspot-max (severity) was significantly related to CCSdiff in KCN (P < 0.0001; R2 = 0.5882) with a weak relationship in NRL (P < 0.0080, R2 = 0.0451). Cspot-max was significantly related to the distance from Pach-min to CCSmax (P < 0.0001; R2 = 0.3737) without significance in NRL (P = 0.8011). Conclusions: Corneal stress is driven by thickness in NRL, with greatest stress at thinnest pachymetry and greatest curvature. However, maximum stress moves away from thinnest pachymetry with progression in KCN, and minimum stress is associated with maximum curvature. Severity in KCN is significantly related to greater difference between maximum and minimum stress, consistent with the biomechanical cycle of decompensation. Financial Disclosures: Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

11.
Mikrochim Acta ; 191(1): 25, 2023 12 13.
Artigo em Inglês | MEDLINE | ID: mdl-38091119

RESUMO

A new nanocomposite consisting of lanthanum ferrite nanoparticles (LaFeO3 NPs) integrated with carbon nanotubes (CNTs) was fabricated via facile sonochemical approach. The engineered nanocomposite was applied to simultaneously determine acetaminophen (ACP) and dopamine (DA) in a binary mixture. The LaFeO3 NPs@CNT probe possesses several advantages such as superior conductivity, large surface area, and more active sites, improving its electrocatalytic activity towards ACP and DA. Under optimized conditions, the anodic peak currents (Ipa) linearly increased with increasing concentration of ACP and DA in the range 0.069-210 µM and 0.15-210 µM, respectively. The sensitivity of LaFeO3 NPs@CNTs/glassy carbon electrode (GCE) for detecting ACP and DA is 7.456 and 5.980 µA·µM-1·cm-2, respectively. The detection limits (S/N = 3) for ACP and DA are 0.02 µM and 0.05 µM, respectively. Advantages of LaFeO3 NPs@CNTs/GCE for the detection of ACP and DA include wide linear ranges, low-detection limits, good selectivity, and long-term stability. The as-fabricated electrode was applied to determine ACP and DA in pharmaceutical formulations and human serum samples with recoveries ranging from 97.7 to 103.3% and an RSD that did not exceed 3.7%, confirming the suitability of the proposed sensor for the determination of ACP and DA in real samples. This study not only presents promising opportunities for enhancing the sensitivity and stability of electrochemical sensors used in the detection of bioanalytes but also significantly contributes to the progress of unique and comprehensive biochemical detection methodologies.


Assuntos
Nanopartículas , Nanotubos de Carbono , Humanos , Nanotubos de Carbono/química , Dopamina , Acetaminofen , Lantânio
12.
RSC Adv ; 13(46): 32492-32501, 2023 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-37928853

RESUMO

We have successfully created a dual-modal probe, labeled as of iron(ii)-ortho-phenanthroline/N, S@g-CDs, which combines both fluorometric and colorimetric techniques for the accurate and sensitive detection of hypochlorite (ClO-). The mechanism behind this probe involves the fluorescence quenching interaction between nitrogen and sulfur co-doped green emissive carbon dots (N, S@g-CDs) and the iron(ii)-ortho-phenanthroline chelate, utilizing both the inner filter effect and redox processes. As the concentration of ClO- increases, the iron(ii) undergo oxidation to iron(iii) as follows: Fe(ii) + 2HClO = Fe(iii) + Cl2O + H2O, leading to the restoration of N, S@g-CDs fluorescence. Simultaneously, the color of the system transitions gradually from red to colorless, enabling colorimetric measurements. In the fluorometric method with an excitation wavelength of 370 nm, the ClO- concentration exhibits a wide linear correlation with fluorescence intensity ranging from 0.07 to 220 µM. The detection limit achieved in this method is 0.02 µM (S/N = 3). In contrast, the colorimetric method exhibits a linear range of 1.12 to 200 µM, with a detection limit of 0.335 µM (S/N = 3). The proposed selective absorbance for this method is 510 nm. The probe has been effectively utilized for the detection of ClO- in various samples, including water and milk samples. This successful application showcases its potential for determining ClO- in complex matrices, highlighting its broad range of practical uses.

13.
Mikrochim Acta ; 190(12): 467, 2023 Nov 13.
Artigo em Inglês | MEDLINE | ID: mdl-37955722

RESUMO

A ratiometric-based fluorescence emission system was proposed for the determination of sulfide. It consists of blue emissive graphene quantum dots (GQDs) and self-assembled thiolate-protected gold nanoclusters driven by aluminum ion (Al3+@GSH-AuNCs). The two types of fluorophores are combined to form a ratiometric emission probe. The orange emission of Al3+ @GSH-AuNCs at 624 nm was quenched in the presence of sulfide ion owing to the strong affinity between sulfide and Au(I), while the blue GQDs fluorescence at 470 nm remained unaffected. Interestingly, the Al3+@GSH-AuNCs and GQDs were excited under the same excitation wavelength (335 nm). The response ratios (F470/F624) are linearly proportional to the sulfide concentration within the linear range of 0.02-200 µM under the optimal settings, with a limit of detection (S/N = 3) of 0.0064 µM. The proposed emission probe was applied to detect sulfide ions in tap water and wastewater specimens, with recoveries ranging from 95.3% to 103.3% and RSD% ranging from 2.3% to 3.4%, supporting the proposed method's accuracy.

14.
Anal Bioanal Chem ; 415(25): 6247-6256, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37667023

RESUMO

An ultrasensitive dual-signal ratiometric electrochemical sensor was developed for creatinine detection utilizing silver nanoparticles (Ag) with intrinsic self-calibration afforded by iron-nickel bimetallic Prussian blue (FeNiPBA) analogues. The Ag@FeNiPBA exhibits two redox signals corresponding to the Ag+/Ag and Fe3+/Fe2+ systems. Adding chloride (Cl-) solution increases the anodic current of the Ag/Ag system significantly due to the formation of silver chloride through solid-state electrochemistry. While the anodic current of the Ag/Ag system decreases in the presence of creatinine due to the competitive reaction, the Fe/Fe system's anodic current remains the same, which enables a ratiometric response. Under optimized conditions, the response ratio (IAg/IFe) decreases while the creatinine concentration increases linearly between 0.015 and 140 µM, with 0.004 µM as a good detection limit (S/N = 3). These results demonstrate superior performance over previously reported methods for electrochemical creatinine determination. The high sensitivity arises from the signal amplification of the Ag/AgCl solid-state electrochemistry, while the selectivity originates from the specific interaction between Ag+ and creatinine. The Ag@FeNiPBA hybrid can quantify creatinine in real samples with good recoveries. This work opens up new opportunities for applying dual-signal nanostructures to develop electrochemical sensors for (bio)molecule detection.

15.
Anal Methods ; 15(34): 4296-4303, 2023 08 31.
Artigo em Inglês | MEDLINE | ID: mdl-37602775

RESUMO

In this study, a novel "on-off-on" fluorescent probe was suggested for sensitive and selective assay of glutathione (GSH). The as-fabricated nanoswitch employs a Cu2+-sulfur quantum dot system (SQ-dots/Cu2+). The surface reactivity and water solubility of SQ-dots were improved through capping with egg white and bovine serum albumin proteins. The surface functional groups on the surface of double protein-protected SQ-dots enhanced the interaction with Cu2+ ions, resulting in the aggregation induced quenching of SQ-dots. Addition of GSH, a strong Cu2+ ion chelator, disassembles the large aggregates into relatively smaller ones, restoring the fluorescence emission of SQ-dots. Under optimized conditions, the fluorescence intensity was increased by increasing GSH amounts within the range of 0.13-550 µM with a detection limit (S/N = 3) of 0.04 µM. The SQ-dots/Cu2+ system was successfully applied for the detection of GSH in different matrices such as dietary supplements, human serum, and vegetable extract samples. The as-fabricated probe holds great potential for the synthesis of other functionalized SQ-dots for (bio) sensing.


Assuntos
Cobre , Pontos Quânticos , Humanos , Glutationa , Íons , Enxofre
16.
RSC Adv ; 13(34): 23736-23744, 2023 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-37555090

RESUMO

Water contamination with harmful ions has grown to be a significant environmental issue on a global scale. Therefore, the fabrication of simple, cost-effective, and reliable sensors is essential for identifying these ions. Herein, co-doping of carbon dots with new caffeine and H3BO3-derived boron (B) and nitrogen (N) was performed (BN@CDs). The as-prepared BN@CDs probe was used for the tandem fluorescence sensing of Al3+ and F- based on "ON-OFF-ON" switches. The BN@CDs nanoswitch has a high quantum yield of 44.8% with λexc. and λem. of 360 nm and 440 nm, respectively. The probe exhibited good stability with different pH, ionic-strengths, and irradiation times. The fluorescence emission of BN@CDs was decreased as the Al3+ concentration was increased with a linear range of 0.03-90 µM and a limit of detection (S/N = 3) equal to 9.0 nM. Addition of F- restored the BN@CDs emission as F- ions form a strong and stable complex with Al3+ ions [Al(OH)3F]-. Therefore, the ratio response (F/F°) was raised by raising the F- ion concentration to the range of 0.18-80 µM with a detection limit (S/N = 3) of 50.0 nM. The BN@CDs sensor exhibits some advantages over other reported methods in terms of simplicity, high quantum yield, and low detection limit. Importantly, the sensor was successfully applied to determine Al3+ and F- in various ecological water specimens with accepted results.

17.
Spectrochim Acta A Mol Biomol Spectrosc ; 303: 123252, 2023 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-37579662

RESUMO

A simple fluorescence method is described for measuring rutin dependent on the nitogen-doped carbon dots (NCDs) prepared via simple pyrolysis method from chicken feet biowaste. The as-fabricated NCDs have unique advantages including cost-effectiveness and high quantum yield (42.9 %). The as-prepared NCDs explore an optimal emission band at 430 nm following exciting NCDs at 330 nm. Addition of rutin to blue-emissive NCDs quenched their fluorescence emission by inner-filtration effect (IFE) and static quenching. Under optimized conditions, the fluorescence responses increased as the rutin amount was raised from 100 to 1000 nmol/L with 5.3 nmol/L as a detection limit (S/N = 3). The probe selectivity was improved by adding bovine serum albumin (BSA), which binds other structurally-related compounds (other flavonoids). The as-synthesized NCDs exhibited some advantages towards rutin detection such as: lower LOD value, satisfactorily reproducibility, simplicity, rapidity, selectivity, and stability. The sensing probe was efficiently utilized for determining rutin in different real samples with acceptable results. The sensor offers an efficient biowaste-based approach for the determination of (bio) molecules.


Assuntos
Pontos Quânticos , Soroalbumina Bovina , Animais , Galinhas , Rutina , Carbono , Nitrogênio , Reprodutibilidade dos Testes , Corantes Fluorescentes , Espectrometria de Fluorescência/métodos
18.
Optom Vis Sci ; 100(10): 688-696, 2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37639554

RESUMO

SIGNIFICANCE: Clinicians and researchers will have evidence whether intereye differences confound clinical measurements of intraocular pressure or of ocular biomechanical parameters. PURPOSE: The purpose of this study was to determine whether intraocular pressure and biomechanical parameters, as measured by the Ocular Response Analyzer (ORA) and by Cornea Visualization with Scheimpflug Technology (CorVis ST), are different between the first and second eye measured. METHODS: Intraocular pressure and biomechanical parameters were collected from both eyes of healthy participants (N = 139). The ORA measured corneal-compensated intraocular pressure, Goldmann-correlated intraocular pressure, and corneal hysteresis. The CorVis ST measured biomechanically corrected intraocular pressure, stiffness parameter at first applanation, and stiffness parameter at highest concavity. For each measurement, a paired t test compared the value of the first eye measured against that of the second eye measured. RESULTS: For the ORA, Goldmann-correlated intraocular pressure was significantly higher ( P = .001) in the first eye (14.8 [3.45] mmHg) than in the second eye (14.3 [3.63] mmHg). For the CorVis ST, biomechanically corrected intraocular pressure was significantly higher ( P < .001) in the second eye (14.7 [2.14] mmHg) than in the first eye (14.3 [2.11] mmHg). Stiffness parameter at first applanation (intereye difference, 6.85 [9.54] mmHg/mm) was significantly ( P < .001) higher in the first eye than in the second eye. Stiffness parameter at highest concavity was significantly higher ( P = .01) in the second eye (14.3 [3.18] mmHg/mm) than in the first eye (14.0 [3.13] mmHg/mm). CONCLUSIONS: Although there were statistically significant intereye differences in intraocular pressure and in biomechanical parameters for both devices, the variations were small and thus unlikely to affect clinical outcomes.


Assuntos
Oftalmopatias , Pressão Intraocular , Humanos , Fenômenos Biomecânicos , Tonometria Ocular , Córnea/fisiologia
19.
Anal Chim Acta ; 1272: 341498, 2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37355332

RESUMO

A novel molecularly imprinted ratiometric-based sensor was designed for highly selective and ultrasensitive electrochemical detection of glutathione (GSH). The sensor consists of porous carbon co-doped with nitrogen and sulfur formed on the surface of graphite electrode (N, S@PC/GE). Silver nanoparticles (Ag) were grown on the surface of N, S@PC/GE to improve the conductivity/surface area of the sensor and represent an internal reference signal for ratiometric response. The monomer (pyrrole-4-carboxylic acid, Py-COOH) was electro-polymerized on the surface of Ag/N, S@PC/GE in the presence of Cu (II) to form Cu-MIP@Ag/N, S@PC/GE. Addition of GSH decreased the signal of Ag at 0.18 V (oxidation of Ag) due to coordination complexation, while the signal response at 0.83 V (oxidation of Ag-GSH complex) was increased. Under optimum conditions, the ratio response (IGSH/IAg) was increased with increasing the concentration of GSH in the range of 0.01-500 nM with a detection limit (S/N = 3) of 0.003 nM. The electrochemical sensor exhibits many advantages including low LOD, high selectivity, good reproducibility, and satisfactory stability. The sensor was successfully applied to determine GSH in dietary supplements and human serum samples with recoveries % ranged from 97.4 to 101.8% and relative standard deviation % (RSD %) did not exceed 3.8%. This research paper introduces new information for the construction of molecular imprinted ratiometric-based electrochemical sensors for highly selective and sensitive detection of (bio) molecules.


Assuntos
Nanopartículas Metálicas , Impressão Molecular , Humanos , Carbono/química , Cobre/química , Prata , Polímeros/química , Reprodutibilidade dos Testes , Porosidade , Glutationa , Eletrodos , Técnicas Eletroquímicas , Limite de Detecção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...