Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nat Commun ; 14(1): 8066, 2023 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-38052834

RESUMO

Understanding the degradation mechanism of organic light-emitting diodes (OLED) is essential to improve device performance and stability. OLED failure, if not process-related, arises mostly from chemical instability. However, the challenges of sampling from nanoscale organic layers and interfaces with enough analytical information has hampered identification of degradation products and mechanisms. Here, we present a high-resolution diagnostic method of OLED degradation using an Orbitrap mass spectrometer equipped with a gas cluster ion beam to gently desorb nanometre levels of materials, providing unambiguous molecular information with 7-nm depth resolution. We chemically depth profile and analyse blue phosphorescent and thermally-activated delayed fluorescent (TADF) OLED devices at different degradation levels. For OLED devices with short operational lifetimes, dominant chemical degradation mainly relate to oxygen loss of molecules that occur at the interface between emission and electron transport layers (EML/ETL) where exciton distribution is maximised, confirmed by emission zone measurements. We also show approximately one order of magnitude increase in lifetime of devices with slightly modified host materials, which present minimal EML/ETL interfacial degradation and show the method can provide insight for future material and device architecture development.

2.
Adv Sci (Weinh) ; 10(35): e2304261, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37916896

RESUMO

Organic semiconductors are a promising material candidate for X-ray detection. However, the low atomic number (Z) of organic semiconductors leads to poor X-ray absorption thus restricting their performance. Herein, the authors propose a new strategy for achieving high-sensitivity performance for X-ray detectors based on organic semiconductors modified with high -Z heteroatoms. X-ray detectors are fabricated with p-type organic semiconductors containing selenium heteroatoms (poly(3-hexyl)selenophene (P3HSe)) in blends with an n-type fullerene derivative ([6,6]-Phenyl C71 butyric acid methyl ester (PC70 BM). When characterized under 70, 100, 150, and 220 kVp X-ray radiation, these heteroatom-containing detectors displayed a superior performance in terms of sensitivity up to 600 ± 11 nC Gy-1  cm-2 with respect to the bismuth oxide (Bi2 O3 ) nanoparticle (NP) sensitized organic detectors. Despite the lower Z of selenium compared to the NPs typically used, the authors identify a more efficient generation of electron-hole pairs, better charge transfer, and charge transport characteristics in heteroatom-incorporated detectors that result in this breakthrough detector performance. The authors also demonstrate flexible X-ray detectors that can be curved to a radius as low as 2 mm with low deviation in X-ray response under 100 repeated bending cycles while maintaining an industry-standard ultra-low dark current of 0.03 ± 0.01 pA mm-2 .

3.
ACS Appl Mater Interfaces ; 14(47): 52779-52793, 2022 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-36382786

RESUMO

Lithium-ion batteries are the most ubiquitous energy storage devices in our everyday lives. However, their energy storage capacity fades over time due to chemical and structural changes in their components, via different degradation mechanisms. Understanding and mitigating these degradation mechanisms is key to reducing capacity fade, thereby enabling improvement in the performance and lifetime of Li-ion batteries, supporting the energy transition to renewables and electrification. In this endeavor, surface analysis techniques are commonly employed to characterize the chemistry and structure at reactive interfaces, where most changes are observed as batteries age. However, battery electrodes are complex systems containing unstable compounds, with large heterogeneities in material properties. Moreover, different degradation mechanisms can affect multiple material properties and occur simultaneously, meaning that a range of complementary techniques must be utilized to obtain a complete picture of electrode degradation. The combination of these issues and the lack of standard measurement protocols and guidelines for data interpretation can lead to a lack of trust in data. Herein, we discuss measurement challenges that affect several key surface analysis techniques being used for Li-ion battery degradation studies: focused ion beam scanning electron microscopy, X-ray photoelectron spectroscopy, Raman spectroscopy, and time-of-flight secondary ion mass spectrometry. We provide recommendations for each technique to improve reproducibility and reduce uncertainty in the analysis of NMC/graphite Li-ion battery electrodes. We also highlight some key measurement issues that should be addressed in future investigations.

4.
J Chem Phys ; 155(17): 174703, 2021 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-34742208

RESUMO

Graphene is an ideal material for biosensors due to the large surface area for multiple bonding sites, the high electrical conductivity allowing for high sensitivity, and the high tensile strength providing durability in fabricated sensor devices. For graphene to be successful as a biosensing platform, selectivity must be achieved through functionalization with specific chemical groups. However, the device performance and sensor sensitivity must still be maintained after functionalization, which can be challenging. We compare phenyl amine and 1,5-diaminonaphthalene functionalization methods for chemical vapor deposition grown graphene, both used to obtain graphene modified with amine groups-which is required for surface attachment of highly selective antibody bio-receptors. Through atomic force microscopy (AFM), Raman spectroscopy, and time-of-flight secondary ion mass spectrometry imaging of co-located areas, the chemistry, thickness, and coverage of the functional groups bound to the graphene surface have been comprehensively analyzed. We demonstrate the modification of functionalized graphene using AFM, which unexpectedly suggests the removal of covalently bonded functional groups, resulting in a "recovered" graphene structure with reduced disorder, confirmed with Raman spectroscopy. This removal explains the decrease in the ID/IG ratio observed in Raman spectra from other studies on functionalized graphene after mechanical strain or a chemical reaction and reveals the possibility of reverting to the non-functionalized graphene structure. Through this study, preferred functionalization processes are recommended to maintain the performance properties of graphene as a biosensor.


Assuntos
Técnicas Biossensoriais , Grafite/química , Compostos Orgânicos/química , Aminas/química , Condutividade Elétrica , Microscopia de Força Atômica
5.
PLoS One ; 11(3): e0152445, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27031102

RESUMO

We have observed that sperm quality parameters indicative of spermatozoa hyperactivation such are lower "linearity" and "straightness", and as showed by this research "elongation", were more pronounced in patients with normal spermiogram compared to the group of men with reduced sperm motility who were undergoing routine in vitro fertilisation. The research encompassed 97 men diagnosed with normozoospermia (n = 20), asthenozoospermia (n = 54) and oligoasthenozoospermia (n = 23). The findings indicate that sperm quality of patients with normal spermiogram diagnosed according to WHO criteria, may be compromised by showing premature spontaneous hyperactivation which can decrease the chances of natural conception. We assessed synergistic effects of multiple chemical elements in ejaculated semen to find if premature spontaneous hyperactivation of spermatozoa can be a sign of imbalanced semen composition especially of elements K, Ca, Cu and Zn. Human semen samples showing low or high baseline status of chemical elements concentrations were found in samples from all three diagnostic groups. However, correlation of K/Ca and Cu/Zn ratios, taking into account samples from all three groups of men, were negative at statistical significance level p = 0.01. We tested if the negative correlation between K/Ca and Cu/Zn ratio works for greater number of semen samples. We found the negative correlation to be valid for 175 semen samples at statistical significance of p = 0.00002. The ratio of K/Ca and Cu/Zn, i.e. increased concentrations of K and Zn in comparison to concentrations of Ca and Cu, were associated with a decrease of "straightness" in the group of men with normal spermiogram and pronounced spontaneous hyperactivation of spermatozoa, implying that these elements act in synergy and that the balance of elements and not their absolute concentrations plays the major role in premature spermatozoa hyperactivation in ejaculated semen.


Assuntos
Cálcio/fisiologia , Cobre/fisiologia , Potássio/fisiologia , Espermatozoides/fisiologia , Zinco/fisiologia , Estudos de Casos e Controles , Humanos , Infertilidade Masculina , Masculino , Sêmen/fisiologia , Motilidade dos Espermatozoides
6.
Anal Chem ; 88(7): 3899-908, 2016 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-26938055

RESUMO

The possibility of recovering undetonated explosive residues following detonation events is well-known; however, the morphology and chemical identity of these condensed phase postblast particles remains undetermined. An understanding of the postblast explosive particle morphology would provide vital information during forensic examinations, allowing rapid initial indication of the explosive material to be microscopically determined prior to any chemical analyses and thereby saving time and resources at the crucial stage of an investigation. In this study, condensed phase particles collected from around the detonations of aluminized ammonium nitrate and RDX-based explosive charges were collected in a novel manner utilizing SEM stubs. By incorporating the use of a focused ion beam during analysis, for the first time it is possible to determine that such particles have characteristic shapes, sizes, and internal structures depending on the explosive and the distance from the detonation at which the particles are recovered. Spheroidal particles (10-210 µm) with microsurface features recovered following inorganic charge detonations were dissimilar to the irregularly shaped particles (5-100 µm) recovered following organic charge firings. Confirmatory analysis to conclude that the particles were indeed explosive included HPLC-MS, Raman spectroscopy, and mega-electron volt-secondary ionization mass spectrometry. These results may impact not only forensic investigations but also the theoretical constructs that govern detonation theory by indicating the potential mechanisms by which these particles survive and how they vary between the different explosive types.


Assuntos
Explosões , Substâncias Explosivas/análise , Nitratos/análise , Triazinas/análise , Tamanho da Partícula
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...