Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
Front Physiol ; 14: 1109524, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37497434

RESUMO

Background: Veno-arterial extracorporeal membrane oxygenation (V-A ECMO) is one of the most frequently used mechanical circulatory support devices. Distribution of extracorporeal membrane oxygenation flow depends (similarly as the cardiac output distribution) on regional vascular resistance. Arteriovenous fistulas (AVFs), used frequently as hemodialysis access, represent a low-resistant circuit which steals part of the systemic perfusion. We tested the hypothesis that the presence of a large Arteriovenous fistulas significantly changes organ perfusion during a partial and a full Veno-arterial extracorporeal membrane oxygenation support. Methods: The protocol was performed on domestic female pigs held under general anesthesia. Cannulas for Veno-arterial extracorporeal membrane oxygenation were inserted into femoral artery and vein. The Arteriovenous fistulas was created using another two high-diameter extracorporeal membrane oxygenation cannulas inserted in the contralateral femoral artery and vein. Catheters, flow probes, flow wires and other sensors were placed for continuous monitoring of haemodynamics and organ perfusion. A stepwise increase in extracorporeal membrane oxygenation flow was considered under beating heart and ventricular fibrillation (VF) with closed and opened Arteriovenous fistulas. Results: Opening of a large Arteriovenous fistulas (blood flow ranging from 1.1 to 2.2 L/min) resulted in decrease of effective systemic blood flow by 17%-30% (p < 0.01 for all steps). This led to a significant decrease of carotid artery flow (ranging from 13% to 25% after Arteriovenous fistulas opening) following VF and under partial extracorporeal membrane oxygenation support. Cerebral tissue oxygenation measured by near infrared spectroscopy also decreased significantly in all steps. These changes occurred even with maintained perfusion pressure. Changes in coronary artery flow were driven by changes in the native cardiac output. Conclusion: A large arteriovenous fistula can completely counteract Veno-arterial extracorporeal membrane oxygenation support unless maximal extracorporeal membrane oxygenation flow is applied. Cerebral blood flow and oxygenation are mainly compromised by the effect of the Arteriovenous fistulas. These effects could influence brain function in patients with Arteriovenous fistulas on Veno-arterial extracorporeal membrane oxygenation.

2.
Front Physiol ; 14: 1180224, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37465699

RESUMO

Background: A large arteriovenous fistula (AVF) is a low-resistant circuit that affects organ perfusion and systemic hemodynamics even in standard conditions. The extent of its' effect in critical states has not been elucidated yet. We used norepinephrine to create systemic vasoconstriction, dobutamine to create high cardiac output, and rapid right ventricle pacing as a model of acute heart failure in a porcine model of high-flow AVF circulation. Methods: The protocol was performed on nine domestic female pigs under general anesthesia. AVF was created by connecting two high-diameter ECMO cannulas inserted in the femoral artery and vein. Continuous hemodynamic monitoring was performed throughout the protocol. Three interventions were performed-moderate dose of norepinephrine (0.25 ug/kg/min), moderate dose of dobutamine (10 ug/kg/min) and rapid right ventricle pacing to simulate low cardiac output state with mean arterial pressure under 60 mmHg. Measurements were taken with opened and closed arteriovenous fistula. Results: Continuous infusion of norepinephrine with opened AVF significantly increased mean arterial pressure (+20%) and total cardiac output (CO) (+36%), but vascular resistance remained virtually unchanged. AVF flow (Qa) rise correlated with mean arterial pressure increase (+20%; R = 0.97, p = 0.0001). Effective cardiac output increased, leading to insignificant improvement in organ perfusion. Dobutamine substantially increased cardiac output with insignificant effect on AVF flow and mean arterial pressure. Carotid artery blood flow increased significantly after dobutamine infusion by approximately 30%, coronary flow velocity increased significantly only in closed AVF state. The effective cardiac output using the heart failure model leading to decrease of carotid artery flow and worsening of brain and peripheral tissue oximetry. AVF blood flow also dropped significantly and proportionally to pressure, but Qa/CO ratio did not change. Therefore, the effective cardiac output decreased. Conclusion: In abovementioned extreme hemodynamic conditions the AVF flow was always directly proportional to systemic perfusion pressure. The ratio of shunt flow to cardiac output depended on systemic vascular resistance. These experiments highlight the detrimental role of a large AVF in these critical conditions' models.

3.
Physiol Res ; 69(4): 609-620, 2020 08 31.
Artigo em Inglês | MEDLINE | ID: mdl-32584136

RESUMO

Veno-arterial extracorporeal membrane oxygenation (VA ECMO) is a technique used in patients with severe heart failure. The aim of this study was to evaluate its effects on left ventricular afterload and fluid accumulation in lungs with electrical impedance tomography (EIT). In eight swine, incremental increases of extracorporeal blood flow (EBF) were applied before and after the induction of ischemic heart failure. Hemodynamic parameters were continuously recorded and computational analysis of EIT was used to determine lung fluid accumulation. With an increase in EBF from 1 to 4 l/min in acute heart failure the associated increase of arterial pressure (raised by 44%) was accompanied with significant decrease of electrical impedance of lung regions. Increasing EBF in healthy circulation did not cause lung impedance changes. Our findings indicate that in severe heart failure EIT may reflect fluid accumulation in lungs due to increasing EBF.


Assuntos
Oxigenação por Membrana Extracorpórea/métodos , Insuficiência Cardíaca/terapia , Pulmão/fisiopatologia , Insuficiência Respiratória/patologia , Animais , Circulação Coronária/fisiologia , Modelos Animais de Doenças , Impedância Elétrica , Oxigenação por Membrana Extracorpórea/efeitos adversos , Feminino , Insuficiência Cardíaca/metabolismo , Insuficiência Cardíaca/patologia , Hemodinâmica , Insuficiência Respiratória/etiologia , Suínos
4.
Rozhl Chir ; 98(6): 233-238, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31331178

RESUMO

The development of a low-flow vascular prosthesis is a very topical issue. The authors present a pathway for the development of a prosthesis with optimal properties based on the idea of mimicking the characteristics of a biological model (saphenous vein graft) and programming these properties in the model of the prosthetic substitute. The vascular prosthesis presented consists of three layers - a non-absorbable scaffold representing vascular “media”, and two absorbable collagen layers - pseudointima and pseudoadventitia. The basic methods of physical testing are presented - the single axis stretch test and inflation-extension test, as well as other procedures that affect the final properties. These include collagen curing, antithrombotic treatment of the inner layer and the use of sterilization methods. The designed new graft was successfully implanted in an ovine model.


Assuntos
Substitutos Sanguíneos , Prótese Vascular , Grau de Desobstrução Vascular , Procedimentos Cirúrgicos Vasculares , Animais , Humanos , Veia Safena , Ovinos
5.
Physiol Res ; 68(4): 667-673, 2019 08 29.
Artigo em Inglês | MEDLINE | ID: mdl-31177789

RESUMO

Electrode migration is the most common complication of spinal cord stimulation (SCS). The problem of longitudinal migration has already been solved, but lateral migration remains the most common current complication. The present article describes new electrodes fixation opportunities for the reduction of lateral migration in SCS. The pig was chosen as an animal model to illustrate a new protocol of electrode fixation for the control of lateral and longitudinal migration. The displacement of the electrode was measured using two different optical methods: the digital image stereo-correlation and the digital image processing methods. Fixation with two anchors has always considerably reduced electrode displacement and when fixation is done with two anchors and a loop then lateral migration is reduced by 62.5 % and longitudinal migration is reduced by 94.1 %. It was shown that the results are significantly different at the alpha=0.001 significance level. Based on a statistical evaluation it is possible to state that the differences between experimental results obtained for three different protocols of lead fixation are statistically significant and we can recommend the new fixation method for common practice.


Assuntos
Eletrodos Implantados/normas , Migração de Corpo Estranho/diagnóstico , Migração de Corpo Estranho/prevenção & controle , Processamento de Imagem Assistida por Computador/métodos , Modelos Animais , Animais , Suínos
6.
Physiol Res ; 68(4): 603-610, 2019 08 29.
Artigo em Inglês | MEDLINE | ID: mdl-31177797

RESUMO

We compared graft outcome between two types of a novel composite three-layer carp-collagen-coated vascular graft in low-flow conditions in a sheep model. Collagen in group A underwent more cycles of purification than in group B in order to increase the ratio between collagen and residual fat. The grafts were implanted end-to-side in both carotid arteries in sheep (14 grafts in 7 sheep in group A, 18 grafts in 9 sheep in group B) and artificially stenosed on the right side. The flow in the grafts in group A decreased from 297±118 ml/min to 158±159 ml/min (p=0.041) after placement of the artificial stenosis in group A, and from 330±164ml/min to 97±29 ml/min (p=0.0052) in group B (p=0.27 between the groups). From the five surviving animals in group A, both grafts occluded in one animal 3 and 14 days after implantation. In group B, from the six surviving animals, only one graft on the left side remained patent (p=0.0017). Histology showed degradation of the intimal layer in the center with endothelization from the periphery in group A and formation of thick fibrous intimal layer in group B. We conclude that the ratio between collagen and lipid content in the novel three-layer graft plays a critical role in its patency and structural changes in vivo.


Assuntos
Prótese Vascular/tendências , Artérias Carótidas/cirurgia , Colágeno/administração & dosagem , Colágeno/isolamento & purificação , Desenho de Prótese/tendências , Grau de Desobstrução Vascular/fisiologia , Animais , Artérias Carótidas/fisiologia , Carpas , Desenho de Prótese/métodos , Ovinos
7.
Physiol Res ; 67(6): 857-862, 2018 12 18.
Artigo em Inglês | MEDLINE | ID: mdl-30204459

RESUMO

The geometry of the distal anastomosis of a femoropopliteal bypass influences local hemodynamics and formation of intimal hyperplasia. We hypothesized that the distal anastomosis of an above-knee femoropopliteal bypass undergoes remodeling that results in displacement of the original course of the popliteal artery and change in the anastomosis angle. We identified 43 CT angiography examination with proximal femoropopliteal bypass and either a preserved contralateral popliteal artery or previous CTA before construction of the bypass for comparison. In these examinations, we measured the displacement distance and angle at the level of the distal anastomosis and compared these measurements with clinical and imaging data. The displacement distance was 8.8+/-4.9 mm (P<0.0001) and the displacement angle was -1° (IQR=44°). The angle between the inflow and outflow artery was 153+/-16° (P<0.0001). There was a negative association between the displacement angle and the angle between the bypass and the outflow artery (r=-0.318, P=0.037). Patients with reversed venous grafts had a greater displacement of the anastomosis (14.7+/-3.0 mm) than patients with prosthetic grafts (8.0+/-4.5 mm, P=0.0011). We conclude that construction of a distal anastomosis of proximal femoropopliteal bypass results in displacement of the original course of the popliteal artery towards the bypass and this effect is more pronounced in reversed venous grafts.


Assuntos
Angiografia por Tomografia Computadorizada/tendências , Artéria Femoral/diagnóstico por imagem , Extremidade Inferior/diagnóstico por imagem , Procedimentos de Cirurgia Plástica/tendências , Artéria Poplítea/diagnóstico por imagem , Remodelação Vascular , Idoso , Anastomose Cirúrgica/tendências , Feminino , Artéria Femoral/fisiologia , Artéria Femoral/cirurgia , Humanos , Extremidade Inferior/irrigação sanguínea , Extremidade Inferior/cirurgia , Masculino , Pessoa de Meia-Idade , Artéria Poplítea/fisiologia , Artéria Poplítea/cirurgia , Estudos Retrospectivos , Remodelação Vascular/fisiologia , Procedimentos Cirúrgicos Vasculares/tendências
8.
Physiol Res ; 67(4): 555-562, 2018 08 16.
Artigo em Inglês | MEDLINE | ID: mdl-29750885

RESUMO

The growth in the experimental research of facilities to support extracorporeal circulation requires the further development of models of acute heart failure that can be well controlled and reproduced. Two types of acute heart failure were examined in domestic pigs (Sus scrofa domestica): a hypoxic model (n=5) with continuous perfusion of the left coronary artery by hypoxic deoxygenated blood and ischemic model (n=9) with proximal closure of the left coronary artery and controlled hypoperfusion behind the closure. The aim was a severe, stable heart pump failure defined by hemodynamic parameters changes: a) decrease in cardiac output by at least 50 %; b) decrease in mixed venous blood saturation to under 60 %; c) left ventricular ejection fraction below 25 %; and d) decrease in flow via the carotid arteries at least 50 %. Acute heart failure developed in the first group in one animal with no acute mortality and in the second group in 8 animals with no acute mortality. In the case of ischemic model the cardiac output fell from 6.70+/-0.89 l/min to 2.89+/-0.75 l/min. The saturation of the mixed venous blood decreased from 83+/-2 % to 58+/-8 %. The left ventricular ejection fraction decreased from 50+/-8 % to 19+/-2 %. The flow via the carotid arteries decreased from 337+/-78 ml/min to 136+/-59 ml/min (P

Assuntos
Modelos Animais de Doenças , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Índice de Gravidade de Doença , Doença Aguda , Animais , Feminino , Hemodinâmica/fisiologia , Sus scrofa , Suínos
9.
Physiol Res ; 66(Suppl 4): S523-S528, 2017 12 30.
Artigo em Inglês | MEDLINE | ID: mdl-29355380

RESUMO

Cardiac resynchronization therapy (CRT) has proven efficacious in reducing or even eliminating cardiac dyssynchrony and thus improving heart failure symptoms. However, quantification of mechanical dyssynchrony is still difficult and identification of CRT candidates is currently based just on the morphology and width of the QRS complex. As standard 12-lead ECG brings only limited information about the pattern of ventricular activation, we aimed to study changes produced by different pacing modes on the body surface potential maps (BSPM). Total of 12 CRT recipients with symptomatic heart failure (NYHA II-IV), sinus rhythm and QRS width >/=120 ms and 12 healthy controls were studied. Mapping system Biosemi (123 unipolar electrodes) was used for BSPM acquisition. Maximum QRS duration, longest and shortest activation times (ATmax and ATmin) and dispersion of QT interval (QTd) were measured and/or calculated during spontaneous rhythm, single-site right- and left-ventricular pacing and biventricular pacing with ECHO-optimized AV delay. Moreover we studied the impact of CRT on the locations of the early and late activated regions of the heart. The average values during the spontaneous rhythm in the group of patients with dyssynchrony (QRS 140.5+/-10.6 ms, ATmax 128.1+/-10.1 ms, ATmin 31.8+/-6.7 ms and QTd 104.3+/-24.7 ms) significantly differed from those measured in the control group (QRS 93.0+/-10.0 ms, ATmax 79.1+/-3.2 ms, ATmin 24.4+/-1.6 ms and QTd 43.6+/-10.7 ms). Right ventricular pacing (RVP) improved significantly only ATmax [111.2+/-10.6 ms (p<0.05)] but no other measured parameters. Left ventricular pacing (LVP) succeeded in improvement of all parameters [QRS 105.1+/-8.0 ms (p<0.01), ATmax 103.7+/-7.1 ms (p<0.01), ATmin 20.2+/-3.7 ms (p<0.01) and QTd 52.0+/-9.4 ms (p<0.01)]. Biventricular pacing (BVP) showed also a beneficial effect in all parameters [QRS 121.3+/-8.9 ms (p<0.05), ATmax 114.3+/-8.2 ms (p<0.05), ATmin 22.0+/-4.1 ms (p<0.01) and QTd 49.8+/-10.0 ms (p<0.01)]. Our results proved beneficial outcome of LVP and BVP in evaluated parameters (what seems to be important particularly in the case of activation times) and revealed a complete return of activation times to normal distribution when using these CRT modalities.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Eletrocardiografia/métodos , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Idoso , Terapia de Ressincronização Cardíaca/tendências , Eletrocardiografia/tendências , Feminino , Insuficiência Cardíaca/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
10.
Physiol Res ; 66(Suppl 4): S529-S536, 2017 12 30.
Artigo em Inglês | MEDLINE | ID: mdl-29355381

RESUMO

Veno-arterial extracorporeal membrane oxygenation (VA-ECMO) is a method used for the treatment most severe cases of decompensated heart failure. The purpose of this study was to evaluate the risk of the formation of microembolisms during VA-ECMO-based therapy. Heart failure was induced with simultaneous detection of microembolisms and the measurement of blood flow rate in the common carotid artery (CCA) without VA-ECMO (0 l/min) and at the VA-ECMO blood flow rate of 1, 2, 3 and 4 l/min. If embolisms for VA-ECMO 0 l/min and the individual regimes for VA-ECMO 1, 2, 3, 4 l/min are compared, a higher VA-ECMO flow rate is accompanied by a higher number of microembolisms. The final microembolism value at 16 min was for the VA-ECMO flow rate of 0 l/min 0.0 (0, 1), VA-ECMO l/min 7.5 (4, 19), VA-ECMO 2 l/min 12.5 (4, 26), VA-ECMO 3 l/min, 21.0 (18, 57) and VA-ECMO 4 l/min, 27.5 (21, 64). Such a comparison is statistically significant if VA-ECMO 0 vs. 4 l/min p<0.0001, 0 vs. 3 l/min p<0.01 and 1 vs. 4 l/min p<0.01 are compared. The results confirm that high VA-ECMO flow rates pose a risk with regards to the formation of a significantly higher number of microemboli in the blood circulation and that an increase in blood flow rates in the CCA corresponds to changes in the VA-ECMO flow rates.


Assuntos
Artéria Carótida Primitiva/diagnóstico por imagem , Modelos Animais de Doenças , Embolia/diagnóstico por imagem , Oxigenação por Membrana Extracorpórea/efeitos adversos , Insuficiência Cardíaca/diagnóstico por imagem , Ultrassonografia Doppler/métodos , Doença Aguda , Animais , Velocidade do Fluxo Sanguíneo/fisiologia , Artéria Carótida Primitiva/fisiopatologia , Embolia/fisiopatologia , Oxigenação por Membrana Extracorpórea/tendências , Feminino , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Microcirculação/fisiologia , Suínos , Ultrassonografia Doppler/tendências
11.
Physiol Res ; 65(Suppl 5): S621-S631, 2016 12 22.
Artigo em Inglês | MEDLINE | ID: mdl-28006944

RESUMO

Venoarterial extracorporeal membrane oxygenation (VA ECMO) is widely used in treatment of decompensated heart failure. Our aim was to investigate its effects on regional perfusion and tissue oxygenation with respect to extracorporeal blood flow (EBF). In five swine, decompensated low-output chronic heart failure was induced by long-term rapid ventricular pacing. Subsequently, VA ECMO was introduced and left ventricular (LV) volume, aortic blood pressure, regional arterial flow and tissue oxygenation were continuously recorded at different levels of EBF. With increasing EBF from minimal to 5 l/min, mean arterial pressure increased from 47+/-22 to 84+/-12 mm Hg (P<0.001) and arterial blood flow increased in carotid artery from 211+/-72 to 479+/-58 ml/min (P<0.01) and in subclavian artery from 103+/-49 to 296+/-54 ml/min (P<0.001). Corresponding brain and brachial tissue oxygenation increased promptly from 57+/-6 to 74+/-3 % and from 37+/-6 to 77+/-6 %, respectively (both P<0.01). Presented results confirm that VA ECMO is a capable form of heart support. Regional arterial flow and tissue oxygenation suggest that partial circulatory support may be sufficient to supply brain and peripheral tissue by oxygen.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Vasos Coronários/metabolismo , Oxigenação por Membrana Extracorpórea/métodos , Insuficiência Cardíaca/metabolismo , Insuficiência Cardíaca/terapia , Oximetria/métodos , Animais , Artérias Carótidas/metabolismo , Doença Crônica , Feminino , Artéria Femoral/metabolismo , Veia Femoral/metabolismo , Artéria Subclávia/metabolismo , Suínos , Resultado do Tratamento
12.
Physiol Res ; 65(Suppl 5): S643-S651, 2016 12 22.
Artigo em Inglês | MEDLINE | ID: mdl-28006946

RESUMO

Acute respiratory distress syndrome (ARDS) is severe medical condition occurring in critically ill patients and with mortality of 33-52 % is one of the leading causes of death in critically ill patients. To better understand pathophysiology of ARDS and to verify novel therapeutical approaches a reliable animal model is needed. Therefore we have developed modified lavage model of ARDS in the pig. After premedication (ketamine and midazolam) 35 healthy pigs were anesthetized (propofol, midazolam, morphin, pipecuronium) and orotracheally intubated and ventilated. Primary ARDS was induced by repeated cycles of lung lavage with a detergent Triton X100 diluted in saline (0.03 %) heated to 37 °C preceded by pre-oxygenation with 100 % O(2). Single cycle included two subsequent lavages followed by detergent suction. Each cycle was followed by hemodynamic and ventilation stabilization for approx. 15 min, with eventual administration of vasopressors according to an arterial blood pressure. The lavage procedure was repeated until the paO(2)/FiO(2) index after stabilization remained below 100 at PEEP 5 cm H(2)O. In 33 pigs we have achieved the desired degree of severe ARDS (PaO(2)/FiO(2)<100). Typical number of lavages was 2-3 (min. 1, max. 5). Hemodynamic tolerance and the need for vasopressors were strongly individual. In remaining two animals an unmanageable hypotension developed. For other subjects the experimental ARDS stability was good and allowed reliable measurement for more than 10 h. The present model of the ARDS is clinically relevant and thus it is suitable for further research of the pathophysiology and management of this serious medical condition.


Assuntos
Lavagem Broncoalveolar/efeitos adversos , Modelos Animais de Doenças , Síndrome do Desconforto Respiratório/etiologia , Síndrome do Desconforto Respiratório/patologia , Animais , Lavagem Broncoalveolar/métodos , Feminino , Pulmão/patologia , Sus scrofa , Suínos
13.
Physiol Res ; 65(4): 711-715, 2016 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-27824481

RESUMO

Despite the urgent need for experimental research in the field of acute heart failure and, particularly cardiogenic shock, currently there are only limited options in large animal models enabling research using devices applied to human subjects. The majority of available models are either associated with an unacceptably high rate of acute mortality or are incapable of developing sufficient severity of acute heart failure. The objective of our research was to develop a novel large animal model of acute severe cardiogenic shock. Advanced left ventricular dysfunction was induced by global myocardial hypoxia by perfusing the upper body (including coronary arteries) with deoxygenated venous blood. The model was tested in 12 pigs: cardiogenic shock with signs of tissue hypoxia developed in all animals with no acute mortality. Cardiac output decreased from a mean (+/- SD) of 6.61+/-1.14 l/min to 2.75+/-0.63 l/min, stroke volume from 79.7+/-9.8 ml to 25.3+/-7.8 ml and left ventricular ejection fraction from 61.2+/-4.3 % to 17.7+/-4.8 % (P

Assuntos
Modelos Animais de Doenças , Hipóxia/complicações , Choque Cardiogênico/etiologia , Animais , Oxigenação por Membrana Extracorpórea , Feminino , Monitorização Fisiológica , Suínos
14.
Physiol Res ; 65(6): 901-908, 2016 12 13.
Artigo em Inglês | MEDLINE | ID: mdl-27539100

RESUMO

Hemodynamics in the distal end-to-side anastomosis is related to early development of intimal hyperplasia and bypass failure. In this study we investigated the effect of diameter ratios between the target artery and the bypass at three different angles of the connection. The pulsatile flow field was visualized using particle image velocimetry in transparent models with three different angles of the connection (25°, 45°, 60°) and the diameter ratio between the bypass and the target artery was 4.6 mm : 6 mm, 6 mm : 6 mm, and 7.5 mm : 6 mm. Six parameters including location and oscillation of the stagnation point, local energy dissipation, wall shear stress (WSS), oscillatory shear index, spatial and temporal gradient of WSS and their distribution in the target artery were calculated from the flow field. In the wider bypass, the stagnation point oscillated in a greater range and was located more proximal to the anastomosis. Energy dissipation was minimal in a wider bypass with a more acute angle. The maximum WSS values were tree times greater in a narrow bypass and concentrated in a smaller circular region at the floor of the anastomosis. The oscillatory shear index increased with wider bypass and more acute angle. The maximum of spatial gradient of WSS concentrated around the floor and toe of the anastomosis and decreased with more acute angle and wider bypass, the temporal gradient of WSS was stretched more towards the side wall. Greater bypass to target vessel ratio and more acute anastomosis angle promote hemodynamics known to reduce formation of intimal hyperplasia.


Assuntos
Anastomose Cirúrgica , Artérias/anatomia & histologia , Artérias/fisiologia , Hemodinâmica , Hiperplasia , Artérias/cirurgia , Velocidade do Fluxo Sanguíneo , Transferência de Energia , Modelos Cardiovasculares , Fluxo Pulsátil , Resistência ao Cisalhamento , Estresse Mecânico , Estresse Fisiológico
15.
Physiol Res ; 65(4): 591-595, 2016 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-26988154

RESUMO

The geometric shape of the distal anastomosis in an infrainguinal bypass has an influence on its durability. In this article, we compared three different angles of the anastomosis with regard to the hemodynamics. Three experimental models of the distal infrainguinal anastomosis with angles of 25°, 45°, and 60° respectively were constructed according to the similarity theory to assess flow in the anastomoses using particle image velocimetry and computational fluid dynamics. In the toe, heel, and floor of the anastomosis that correspond to the locations worst affected by intimal hyperplasia, adverse blood flow and wall shear stress were observed in the 45° and 60° models. In the 25° model, laminar blood flow was apparent more peripherally from the anastomosis. In conclusions, decreasing the distal anastomosis angle in a femoropopliteal bypass results in more favorable hemodynamics including the flow pattern and wall shear stress in locations susceptible to intimal hyperplasia.


Assuntos
Extremidade Inferior/irrigação sanguínea , Procedimentos Cirúrgicos Vasculares/métodos , Anastomose Cirúrgica/métodos , Hemodinâmica , Hemorreologia , Humanos
16.
Physiol Res ; 64(Suppl 5): S677-83, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26674293

RESUMO

The aims were to explore the effect of head-up tilt (HUT) to 30 and 60 degrees on hemodynamics and tissue oxygenation in anesthetized healthy swine. The data serve as a reference for a study of resuscitation efficacy at HUT such as during transport. Nine healthy swine (49+/-4 kg) were anesthetized and multiple sensors including myocardial pressure-volume loops catheter, carotid flow probe, blood pressure catheters, near infrared spectroscopy (NIRS) tissue oximetry and mixed venous oximetry (SVO2) catheter were introduced and parameters continuously recorded. Experimental protocol consisted of baseline in supine position (15 min), 30 degrees HUT (15 min), recovery at supine position (15 min) and 60 degrees HUT (5 min). Vacuum mattress was used for body fixation during tilts. We found that 30 and 60 degrees inclination led to significant immediate reduction in hemodynamic and oximetry parameters. Mean arterial pressure (mm Hg) decreased from 98 at baseline to 53 and 39, respectively. Carotid blood flow dropped to 47 % and 22 % of baseline values, end diastolic volume to 49 % and 53 % and stroke volume to 47 % and 45 % of baseline. SVO2 and tissue oximetry decreased by 17 and 21 percentage points. The values are means. In conclusions, within minutes, both 30 and 60 degrees head-up tilting is poorly tolerated in anesthetized swine. Significant differences among individual animals exist.


Assuntos
Anestesia Geral , Hemodinâmica , Intolerância Ortostática/fisiopatologia , Postura , Animais , Pressão Arterial , Artérias Carótidas/fisiopatologia , Modelos Animais , Intolerância Ortostática/sangue , Oximetria/métodos , Oxigênio/sangue , Consumo de Oxigênio , Fluxo Sanguíneo Regional , Espectroscopia de Luz Próxima ao Infravermelho , Decúbito Dorsal , Suínos , Teste da Mesa Inclinada , Fatores de Tempo
17.
Physiol Res ; 63(6): 733-41, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25157655

RESUMO

In order to study a possible effect of mini-invasive heart intervention on a response of hypothalamo-pituitary-adrenal stress axis, we analyzed four stress markers (cortisol, cortisone, DHEA and DHEAS) in 25 sows using minimally invasive heart catheterisation as the stress factor. The marker levels were assessed in four periods of the experiment, (1) the baseline level on the day before intervention, (2) after the introduction of anesthesia, (3) after conducting tissue stimulation or ablation, and (4) after the end of the catheterisation. For statistical analyses we used the non-parametric Friedman test for four dependent samples (including all four stages of the operation) or three dependent samples (influence of operation only, baseline level was excluded). Statistically significant differences in both Friedman tests were found for cortisol and for cortisone. Significant differences for DHEA as well as for DHEAS were found for all tested stages but not for the effect of operation itself. We have concluded that cortisol levels are blunted by the influence of anesthesia after its administration, and therefore decrease back to the baseline at the end of the operation. The other markers (cortisone, DHEA and DHEAS) acted as balanced systems against the injurious stress effect.


Assuntos
Cateterismo Cardíaco/efeitos adversos , Hormônios/metabolismo , Estresse Psicológico/metabolismo , Hormônio Adrenocorticotrópico/metabolismo , Anestesia , Animais , Cortisona/metabolismo , Desidroepiandrosterona/metabolismo , Sulfato de Desidroepiandrosterona/metabolismo , Feminino , Hidrocortisona/metabolismo , Suínos
18.
Physiol Res ; 63(Suppl 4): S451-8, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25669676

RESUMO

It has become increasingly apparent in recent years that there are important differences of many cardiovascular disorders including ventricular tachycardias in men and women. Nevertheless, so far just few studies have addressed possible gender differences in electrophysiological characteristics of idiopathic ventricular tachycardia from right ventricular outflow tract (RVOT-VT), other than epidemiological ones. This study explored possible gender differences in electrophysiological characteristics and catheter ablation outcome in RVOT-VT patients. Ninety-three patients (mean age 38.7+/-15.5 years, 30 males) with idiopathic RVOT-VT were enrolled and analyzed in our study. Male patients had longer QRS width (99.9+/-19.4 ms vs. 88.4+/-20.7 ms, p=0.02). Female patients had lower right ventricular mean voltage (3.0+/-0.7 mV vs. 3.7+/-0.9 mV, p=0.03), and more low voltage zone over the right ventricular outflow tract free wall (27.0 % vs. 6.7 %, p=0.02). Eighty-one patients passed catheter ablation (23 males). The acute success rate, repeated catheter ablation rate and VT recurrence rate were similar in both genders. The present study provides evidence of the gender differences in electrophysiological findings in patients with idiopathic RVOT-VT. Studies on gender-specific differences in arrhythmia could lead to a better understanding of its mechanism(s) and provide valuable information for the development of optimal treatment strategies.


Assuntos
Ablação por Cateter/estatística & dados numéricos , Ventrículos do Coração/fisiopatologia , Caracteres Sexuais , Taquicardia Ventricular/fisiopatologia , Adulto , Ecocardiografia/estatística & dados numéricos , Eletrocardiografia/estatística & dados numéricos , Feminino , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/cirurgia , Resultado do Tratamento , Adulto Jovem
19.
Physiol Res ; 62(Suppl 1): S165-71, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24329696

RESUMO

The aim of our study was to compare the responses of heart rate variability (HRV) with two different types of hormonal substitution therapy (HT) in post-menopausal women (cross-sectional study) and to reveal an effect of HT shortly after beginning of its administration (follow-up study). To elucidate the influence of menopause and effects of different protocols of a HT on autonomic control of heart rate, we evaluated the heart rate variability (HRV) in 5 groups: premenopausal women (n=140), postmenopausal women without HT (n=360), women on HT with conjugated estrogen only (n=168), women on continuous combined estrogen-progesterone HT (n=117), and men (n=140). Frequency-domain of short-term stationary R-R intervals was performed to evaluate the total variance, low frequency power (LF; 0.04-0.15 Hz), high frequency power (HF; 0.15-0.40 Hz), portion of low frequency power (LF%) and ratio of LF to HF (LF/HF). Significantly lower portion of the LF was found in premenopausal women [46.9 (+/-2.7) nu] when compared to untreated postmenopausal women [54.3 (+/-2.9) nu] and men [55.2 (+/-3.0) nu]. Treatment by estrogen only was proved to decrease the LF% [40.1 (+/-2.1) nu] while no effect on HRV was observed in women treated with combination of estrogen and progesterone [57.2 (+/-3.1) nu]. Also the HF was lower in postmenopausal women [4.16 (+/-0.16) ms(2)] than in premenopausal women [4.79 (+/-0.22) ms(2)] and women treated with estrogen only [4.98 (+/-0.25) ms(2)] while in women treated with combined hormonal therapy the average value [3.99 (+/-0.21) ms(2)] did not significantly differ from that of untreated postmenopausal women. The follow-up study also proved increase of high frequency power already after two months of estrogen substitution therapy [4.86 (+/-0.14) ms(2) vs. 4.19 (+/-0.15) ms(2)]. These results suggest that higher vagal modulation of heart rate that seems typical for younger women becomes after menopause similar to that of men. We also proved a positive shift of HRV parameters toward more beneficial values as for a cardiovascular risk in postmenopausal women treated with estrogens but not in those treated by combined estrogen - progesterone substitution therapy.


Assuntos
Estrogênios/administração & dosagem , Frequência Cardíaca/efeitos dos fármacos , Frequência Cardíaca/fisiologia , Terapia de Reposição Hormonal/métodos , Menopausa/fisiologia , Progesterona/administração & dosagem , Estudos Transversais , Quimioterapia Combinada , Feminino , Humanos , Masculino , Menopausa/efeitos dos fármacos , Pessoa de Meia-Idade
20.
Physiol Res ; 62(Suppl 1): S173-9, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24329697

RESUMO

Early recognition of collapsing hemodynamics in pulmonary embolism is necessary to avoid cardiac arrest using aggressive medical therapy or mechanical cardiac support. The aim of the study was to identify the maximal acute hemodynamic compensatory steady state. Overall, 40 dynamic obstructions of pulmonary artery were performed and hemodynamic data were collected. Occlusion of only left or right pulmonary artery did not lead to the hemodynamic collapse. When gradually obstructing the bifurcation, the right ventricle end-diastolic area expanded proportionally to pulmonary artery mean pressure from 11.6 (10.1, 14.1) to 17.8 (16.1, 18.8) cm(2) (p<0.0001) and pulmonary artery mean pressure increased from 22 (20, 24) to 44 (41, 47) mmHg (p<0.0001) at the point of maximal hemodynamic compensatory steady state. Similarly, mean arterial pressure decreased from 96 (87, 101) to 60 (53, 78) mmHg (p<0.0001), central venous pressure increased from 4 (4, 5) to 7 (6, 8) mmHg (p<0.0001), heart rate increased from 92 (88, 97) to 147 (122, 165) /min (p<0.0001), continuous cardiac output dropped from 5.2 (4.7, 5.8) to 4.3 (3.7, 5.0) l/min (p=0.0023), modified shock index increased from 0.99 (0.81, 1.10) to 2.31 (1.99, 2.72), p<0.0001. In conclusion, instead of continuous cardiac output all of the analyzed parameters can sensitively determine the individual maximal compensatory response to obstructive shock. We assume their monitoring can be used to predict the critical phase of the hemodynamic status in routine practice.


Assuntos
Modelos Animais de Doenças , Artéria Pulmonar/fisiopatologia , Circulação Pulmonar , Embolia Pulmonar/complicações , Embolia Pulmonar/fisiopatologia , Choque/etiologia , Choque/fisiopatologia , Animais , Velocidade do Fluxo Sanguíneo , Pressão Sanguínea , Débito Cardíaco , Feminino , Frequência Cardíaca , Humanos , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...