Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Alzheimers Dement (N Y) ; 5: 374-381, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31440580

RESUMO

INTRODUCTION: Preclinical studies support investigation of focused ultrasound for breakdown of cerebral pathologies in neurodegenerative conditions including Alzheimer's disease (AD) and Parkinson's disease (PD). METHODS: A focused transcranial Doppler device with probes (2 MHz, 520 mW/cm2) affixed bilaterally was used to target the hippocampus (AD) or substantia nigra (PD) with functional magnetic resonance imaging navigation for enhanced plaque removal. A total of 22 patients (n = 11 AD, n = 11 PD) underwent 8 consecutive, weekly, 1-hour treatments wherein sleep was encouraged naturally or pharmacologically. Cognitive and motor functioning assessment was carried out using standardized evaluations at baseline and conclusion. RESULTS: Of all, 62.5% of patients had one or more improved cognitive scores without data incongruence, 87% had stable or improved fine motor scores, and 87.5% had stable or improved gross motor scores. No adverse events were reported. DISCUSSION: The safety of focused transcranial Doppler and possible enhancement in patient functioning were suggested by outcome data.

2.
Heart Fail Rev ; 10(4): 265-73, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16583174

RESUMO

BACKGROUND: To assess the feasibility of a fast, flow-insensitive magnetic resonance imaging (MRI) protocol in heart failure patients for the evaluation of cardiac function, cardiovascular anatomy, and myocardial viability. METHODS AND RESULTS: Thirty-two consecutive patients with left ventricular (LV) systolic dysfunction and 13 control subjects were prospectively evaluated with MRI. The exam consisted of cine imaging with a steady-state free precession sequence, followed by time-resolved, three-dimensional angiography and delayed, contrast-enhanced imaging. Multiple LV parameters were evaluated, and the heart failure and control results were compared. In 12 patients, MRI-determined ejection fractions were compared to echocardiographic values. Additionally, a qualitative analysis of the cine images was performed. The cardiac MR evaluation yielded diagnostic-quality images in all subjects. Mean imaging time was 37 min. MRI demonstrated significant differences between the heart failure and control subjects in all parameters assessed (p < 0.05). MRI-determined ejection fractions correlated strongly with echocardiographic values (R = 0.75), although the limits of agreement were wide (-17.3%-18.3%). CONCLUSIONS: Using fast, flow-insensitive imaging techniques, MRI is feasible in heart failure for the derivation of more independent indices of cardiac status than any other non-invasive test. Although further investigation is warranted, MRI may prove uniquely helpful in heart failure diagnosis and management.


Assuntos
Insuficiência Cardíaca/patologia , Imageamento por Ressonância Magnética , Adulto , Idoso , Ecocardiografia , Estudos de Viabilidade , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/fisiopatologia , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade , Volume Sistólico , Disfunção Ventricular Esquerda/patologia
3.
AJR Am J Roentgenol ; 178(3): 543-9, 2002 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11856670

RESUMO

OBJECTIVE: The purpose of this study was to evaluate the effect of breathing on image quality of the aortic arch and carotid vessels during contrast-enhanced MR angiography and to show that high-resolution breath-hold contrast-enhanced MR angiography combined with a timing-bolus technique can produce high-quality images of the entire carotid circulation. MATERIALS AND METHODS: Forty patients underwent high-resolution contrast-enhanced MR angiography on a 1.5-T Magnetom Symphony. A coronal three-dimensional (3D) gradient-echo sequence (TR/TE, 4.36/1.64; flip angle, 25 degrees) with asymmetric k-space acquisition was used. The 136 x 512 matrix yielded voxel sizes of 1.33 x 0.64 x 1.0 mm. A timing-bolus acquisition, orientated in the coronal plane to include the aortic arch, was obtained initially during free-breathing. Twenty milliliters of gadopenetate dimeglumine was injected at 2 mL/sec. Unenhanced and enhanced 3D volumes were recorded. A subtracted 3D set was calculated and subjected to a maximum-intensity-projection algorithm. Half of the patients held their breath during angiography and the other half did not. Aortic arch motion was measured on the timing-bolus acquisition as the distance moved by a single pixel in both the x and y directions. Maximum-intensity-projection MR images were assessed independently by two observers, and vessel sharpness was scored on a scale of 1-5. Sharpness was also assessed quantitatively by generating a signal intensity profile across the aortic arch vessel wall and calculating the average of the upslope and downslope at full-width half maximum. Visualization of carotid branch vessels was scored on a scale of 0-5, and venous contamination was scored on a scale of 0-3. RESULTS: Average in-plane aortic arch movement was 10.3 mm in the x direction and 8.7 mm in the y direction. Quantitative and qualitative sharpness of the aortic arch and great vessel origins was better (p < 0.05) during breath-holding than during non-breath-holding. No difference in the sharpness of the carotid vessels was noted between the two groups. Carotid branch vessels were well visualized from the aortic arch to the intracerebral circulation. The average venous contamination score was 0.56. CONCLUSION: Breath-holding greatly improves the sharpness of the aortic arch and great vessel origins but has no effect on visualization of the carotid vessels. High-resolution breath-hold contrast-enhanced MR angiography can produce high-quality, artifact-free images of the entire carotid circulation from the aortic arch to the intracerebral circulation.


Assuntos
Artérias Carótidas/patologia , Doenças das Artérias Carótidas/diagnóstico , Meios de Contraste , Angiografia por Ressonância Magnética , Idoso , Aorta Torácica/patologia , Feminino , Gadolínio DTPA , Humanos , Aumento da Imagem , Angiografia por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Respiração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...