Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
JACC Cardiovasc Interv ; 15(15): 1543-1554, 2022 08 08.
Artigo em Inglês | MEDLINE | ID: mdl-35926921

RESUMO

BACKGROUND: As transcatheter aortic valve (TAV) replacement is increasingly used in patients with longer life expectancy, a sizable proportion will require redo TAV replacement (TAVR). The unique configuration of balloon-expandable TAV (bTAV) vs a self-expanding TAV (sTAV) potentially affects TAV-in-TAV outcome. OBJECTIVES: The purpose of this study was to better inform prosthesis selection, TAV-in-TAV outcomes were assessed according to the type of initial and subsequent TAV. METHODS: Patients from the Redo-TAVR registry were analyzed using propensity weighting according to their initial valve type (bTAV [n = 115] vs sTAV [n = 106]) and subsequent valve type (bTAV [n = 130] vs sTAV [n = 91]). RESULTS: Patients with failed bTAVs presented later (vs sTAV) (4.9 ± 2.1 years vs 3.7 ± 2.3 years; P < 0.001), with smaller effective orifice area (1.0 ± 0.7 cm2 vs 1.3 ± 0.8 cm2; P = 0.018) and less frequent dominant regurgitation (16.2% vs 47.3%; P < 0.001). Mortality at 30 days was 2.3% (TAV-in-bTAV) vs 0% (TAV-in-sTAV) (P = 0.499) and 1.7% (bTAV-in-TAV) vs 1.0% (sTAV-in-TAV) (P = 0.612); procedural safety was 72.6% (TAV-in-bTAV) vs 71.2% (TAV-in-sTAV) (P = 0.817) and 73.2% (bTAV-in-TAV) vs 76.5% (sTAV-in-TAV) (P = 0.590). Device success was similar according to initial valve type but higher with subsequent sTAV vs bTAV (77.2% vs 64.3%; P = 0.045), primarily because of lower residual gradients (10.3 mm Hg [8.9-11.7 mm Hg] vs 15.2 mm Hg [13.2-17.1 mm Hg]; P < 0.001). Residual regurgitation (moderate or greater) was similar after bTAV-in-TAV and sTAV-in-TAV (5.7%) and nominally higher after TAV-in-bTAV (9.1%) vs TAV-in-sTAV (4.4%) (P = 0.176). CONCLUSIONS: In selected patients, no association was observed between TAV type and redo TAVR safety or mortality, yet subsequent sTAV was associated with higher device success because of lower redo gradients. These findings are preliminary, and more data are needed to guide valve choice for redo TAVR.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Sistema de Registros , Fatores de Risco , Resultado do Tratamento
2.
Front Cardiovasc Med ; 9: 847259, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35355970

RESUMO

Background: Transcatheter heart valve (THV) selection for transcatheter aortic valve implantation (TAVI) is crucial to achieve procedural success. Borderline aortic annulus size (BAAS), which allows a choice between two consecutive valve sizes, is a common challenge during device selection. In the present study, we evaluated TAVI outcomes in patients with BAAS according to THV size selection. Methods: We performed a retrospective study including patients with severe aortic stenosis (AS) and BAAS, measured by multi-detector computed tomography (MDCT), undergoing TAVI with self-expandable (SE) or balloon-expandable (BE) THV from the Israeli multi-center TAVI registry. The aim was to evaluate outcomes of TAVI, mainly paravalvular leak (PVL) and valve hemodynamics, in patients with BAAS (based on MDCT) according to THV sizing selection in between 2 valve sizes. In addition, to investigate the benefit of shifting between different THV types (BE and SE) to avoid valve size selection in BAAS. Results: Out of 2,352 patients with MDCT measurements, 598 patients with BAAS as defined for at least one THV type were included in the study. In BAAS patients treated with SE-THV, larger THV selection was associated with lower rate of PVL, compared to smaller THV (45.3 vs. 64.5%; pv = 0.0038). Regarding BE-THV, larger valve selection was associated with lower post-procedural transvalvular gradients compared to smaller THV (mean gradient: 9.9 ± 3.7 vs. 12.5 ± 7.2 mmHg; p = 0.019). Of note, rates of mortality, left bundle branch block, permanent pacemaker implantation, stroke, annular rupture, and/or coronary occlusion did not differ between groups. Conclusion: BAAS is common among patients undergoing TAVI. Selection of a larger THV in these patients is associated with lower rates of PVL and optimized THV hemodynamics with no effect on procedural complications. Additionally, shift from borderline THV to non-borderline THV modified both THV hemodynamics and post-dilatation rates.

3.
Am J Cardiol ; 156: 101-107, 2021 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-34344509

RESUMO

There is a growing interest in transcutaneous aortic valve implantation (TAVI) therapy among patients with bicuspid severe aortic stenosis (BAV). Conduction disturbances remain a frequent complication of TAVI, and new-onset permanent LBBB (NOP-LBBB) post-TAVI may be a marker of worse outcomes. We aimed to evaluate the rate of NOP-LBBB following TAVI among patients with BAV as compared to tricuspid severe aortic stenosis (TAV). Patients enrolled in the multicenter (5 centers) Bicuspid AS TAVI Registry were reviewed and compared with patients with TAV. Patients with previous aortic valve replacement, other valve morphologies and those with preprocedural LBBB or pacemaker were excluded. NOP-LBBB was defined as LBBB first detected and persisting 30-days following TAVI. A total of 387 patients (66 with BAV, 321 with TAV), age 80.3 ± 7.3, 47% females were analyzed. The device success rates were 95% in both groups without any conversions to surgery. The rate of NOP-LBBB was significantly higher among patients with BAV versus TAV (29.2% vs 16.9%, p = 0.02). However, the rate of post procedural pacemaker implantation was similar (14.8% vs 12.5%; respectively, p = 0.62). In BAV and TAV groups, 1-year mortality (6.1% vs 7.2%; respectively, p = 0.75) and stroke rates (6.1% vs 3.5%; respectively, p = 0.30) were not significantly different. Multivariate analysis identified BAV as an independent predictor of NOP-LBBB (AdjOR = 2.7, 95%CI 1.3 to 5.4). Furthermore, BAV subtypes with raphe (type 1) were identified as independent predictors of NOP-LBBB (AdjOR = 3.2, 95%CI: 1.5 to 6.7). In conclusion, patients with BAV undergoing TAVI have greater risk for developing NOP-LBBB compared with patients with TAV and the presence of raphe was associated with increased risk of NOP-LBBB. The prognostic significance for this finding warrants further evaluation in future studies.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bloqueio de Ramo/epidemiologia , Eletrocardiografia , Sistema de Registros , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Bloqueio de Ramo/etiologia , Bloqueio de Ramo/fisiopatologia , Feminino , Seguimentos , Humanos , Incidência , Israel/epidemiologia , Masculino , Estudos Retrospectivos , Taxa de Sobrevida/tendências , Resultado do Tratamento
4.
J Am Coll Cardiol ; 77(1): 1-14, 2021 01 05.
Artigo em Inglês | MEDLINE | ID: mdl-33413929

RESUMO

BACKGROUND: Surgical aortic valve replacement and transcatheter aortic valve replacement (TAVR) are now both used to treat aortic stenosis in patients in whom life expectancy may exceed valve durability. The choice of initial bioprosthesis should therefore consider the relative safety and efficacy of potential subsequent interventions. OBJECTIVES: The aim of this study was to compare TAVR in failed transcatheter aortic valves (TAVs) versus surgical aortic valves (SAVs). METHODS: Data were collected on 434 TAV-in-TAV and 624 TAV-in-SAV consecutive procedures performed at centers participating in the Redo-TAVR international registry. Propensity score matching was applied, and 330 matched (165:165) patients were analyzed. Principal endpoints were procedural success, procedural safety, and mortality at 30 days and 1 year. RESULTS: For TAV-in-TAV versus TAV-in-SAV, procedural success was observed in 120 (72.7%) versus 103 (62.4%) patients (p = 0.045), driven by a numerically lower frequency of residual high valve gradient (p = 0.095), ectopic valve deployment (p = 0.081), coronary obstruction (p = 0.091), and conversion to open heart surgery (p = 0.082). Procedural safety was achieved in 116 (70.3%) versus 119 (72.1%) patients (p = 0.715). Mortality at 30 days was 5 (3%) after TAV-in-TAV and 7 (4.4%) after TAV-in-SAV (p = 0.570). At 1 year, mortality was 12 (11.9%) and 10 (10.2%), respectively (p = 0.633). Aortic valve area was larger (1.55 ± 0.5 cm2 vs. 1.37 ± 0.5 cm2; p = 0.040), and the mean residual gradient was lower (12.6 ± 5.2 mm Hg vs. 14.9 ± 5.2 mm Hg; p = 0.011) after TAV-in-TAV. The rate of moderate or greater residual aortic regurgitation was similar, but mild aortic regurgitation was more frequent after TAV-in-TAV (p = 0.003). CONCLUSIONS: In propensity score-matched cohorts of TAV-in-TAV versus TAV-in-SAV patients, TAV-in-TAV was associated with higher procedural success and similar procedural safety or mortality.


Assuntos
Estenose da Valva Aórtica/cirurgia , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Injúria Renal Aguda/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/mortalidade , Conversão para Cirurgia Aberta/estatística & dados numéricos , Oclusão Coronária/epidemiologia , Feminino , Hemorragia/epidemiologia , Humanos , Masculino , Marca-Passo Artificial/estatística & dados numéricos , Segurança do Paciente , Pontuação de Propensão , Sistema de Registros
5.
J Interv Card Electrophysiol ; 62(2): 299-307, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33098042

RESUMO

PURPOSE: This study sought to identify risk factors for permanent pacemaker implantation (PPMI) after Transcatheter aortic valve implantation (TAVI) and explain their trends over the last decade. TAVI is performed nowadays for severe aortic stenosis in more patients with lower surgical risk. While most TAVI complications have been reduced, PPMI remains common. METHODS: In this observational, retrospective cohort analysis, 338 TAVI patients treated between 2008 and 2017 were reviewed. Risk factors were compared between the early (2008-2013) and late years (2014-2017), and a multivariable logistic regression model was used. RESULTS: A decreasing trend in PPMI over time was observed (p for trend = 0.008), as was a lower rate of PPMI in the late period (19.3% vs. 31.7%, p = 0.009). Three variables were identified as independent risk factors for PPMI that also decreased significantly in the late period: valve implantation depth ≥ 8 mm (OR = 4.3, 95% CI 2.3-8.2, p < 0.001), use of self-expandable valves (OR = 2.8, 95% CI 1.4-5.5, p = 0.004), and patient risk assessed by EuroSCORE II (OR = 1.07, 95% CI 1.0-1.1, p = 0.034). Indications for PPMI were also shown to change over time, with an increase in the prevalence of complete AVB as the main indication for PPMI (p = 0.048), and a trend towards a decrease in LBBB alone (p = 0.061). CONCLUSIONS: The decrease in post-TAVI PPMI over the past decade is multifactorial and can be explained by (1) lower baseline patient surgical risk, (2) modified procedural variables including decreased implantation depth and increased use of balloon-expandable valves, and (3) refined indications for PPMI.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
6.
Catheter Cardiovasc Interv ; 97(6): E868-E874, 2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-32865879

RESUMO

INTRODUCTION: Percutaneous mitral valve repair (PMVR), such as MitraClip, is performed on high-risk patients and involves hemodynamic alternations that may cause acute kidney injury (AKI). We aimed to evaluate the incidence of AKI, predictors for developing AKI and the correlation with mortality after MitraClip. METHODS: We performed a retrospective analysis of collected data from patients who underwent PMVR in two tertiary medical centers in Israel to identify factors associated with AKI. RESULTS: The study population included 163 patients. The median age was 77 years; 60.7% of patients were male. The median eGFR significantly decreased post-procedure from 49 (35-72) to 47.8 (31-65.5) ml/min/1.73 m2 (p < .001). Forty-seven patients (29%) developed AKI. None of the patients who developed AKI required hemodialysis. Predictors of AKI included: baseline eGFR ≤30 ml/min/1.73 m2 , severity of residual MR, TMPG>5 mmHg, diuretic use, and re-do procedures. Among the patients who developed AKI there was an improvement in kidney function during follow-up, and creatinine levels significantly decreased from a peak mean creatinine of 179.5 (143-252) mmol/l to 136 (92-174) mmol/l (p < .001). However, 19% (9 out of 47) of patients experienced partial recovery and their creatinine level, when compared to their baseline, remained elevated. One-year survival showed a trend for increased mortality among patients who developed AKI (86.2% vs. 80.9%, p = .4), and patients who developed AKI that persisted had increased 1-year mortality compared with patients that had recovered their kidney function (86.8% vs. 55.6%, p = .01). CONCLUSION: The incidence of AKI after MitraClip is high. AKI is reversible in most patients; however, the persistence of kidney injury is associated with increased 1-year mortality.


Assuntos
Injúria Renal Aguda , Insuficiência da Valva Mitral , Injúria Renal Aguda/diagnóstico , Injúria Renal Aguda/epidemiologia , Injúria Renal Aguda/etiologia , Idoso , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
7.
Cardiovasc Revasc Med ; 25: 1-8, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33168433

RESUMO

Treatment of lesions in small coronary vessels is associated with an increased risk of adverse cardiovascular events after percutaneous coronary intervention (PCI).We aimed to evaluate the outcomes of patients undergoing small-vessel PCI in the BIONICS trial and to identify predictors of stent failure. 1910 patients were randomized to treatment with the EluNIR™ ridaforolimus-eluting stent (RES) or Resolute™ zotarolimus-eluting stent (ZES). Small vessels were defined as reference vessel diameters (RVD) ≤2.5 mm. A Cox proportional hazards model was used to identify predictors of target lesion failure (TLF) through 2 years. Patients undergoing small vessel disease PCI had a higher frequency of diabetes, prior myocardial infarction (MI), and prior PCI. 2 year TLF was higher among patients with small vessels (9.7% vs. 5.9%, HR 1.7 [95% CI 1.22-2.37], p < 0.01), driven by increased rates of target vessel-MI and target lesion revascularization (TLR). Stent thrombosis at 2 years was higher among patients with small vessel disease (1.4% vs. 0.3%, HR 5.25 [95% CI 1.47-18.8], p < 0.01). 2 year TLF rates were similar in the RES and ZES patient groups (Pinteraction 0.86). In conclusion, patients undergoing PCI in small vessels have significantly worse outcomes despite the use of contemporary stents.


Assuntos
Fármacos Cardiovasculares , Stents Farmacológicos , Intervenção Coronária Percutânea , Biônica , Fármacos Cardiovasculares/efeitos adversos , Humanos , Incidência , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
8.
ESC Heart Fail ; 7(6): 4071-4079, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33085190

RESUMO

AIMS: We evaluated the impact of MitraClip on systolic pulmonary artery pressure (sPAP) and the effects of baseline sPAP on outcomes. METHODS AND RESULTS: In a cohort of patients who underwent MitraClip implantation, three groups were defined according to pre-procedure sPAP levels. Clinical and echocardiographic data were compared. The study included 177 patients: 59 had severe pulmonary hypertension (PHT), 96 had mild to moderate PHT, and 22 had no PHT. In patients with pre-existing severe PHT, sPAP was reduced from 70.8 ± 9.2 to 56.8 ± 13.7 mmHg (P < 0.001), sPAP remained unchanged in patients with mild to moderate PHT but was significantly increased from 30.8 ± 4.3 to 38.6 ± 8.3 mmHg in the no-PHT group (P < 0.001). Improvement of sPAP was observed in 77% of severe PHT group, while worsening of sPAP was more common among patients with no-PHT [57% compared with 33% among the mild to moderate PHT and 7% in the severe PHT group, respectively, (P < 0.001)]. One year survival was similar among the study groups. CONCLUSIONS: MitraClip decreases PHT among patients with severe PHT. A concerning finding is that most patients with no-PHT increase their sPAP.

9.
Am J Cardiol ; 126: 8-15, 2020 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-32317100

RESUMO

Treatment of bifurcation lesions is technically challenging and has been associated with an increased risk of adverse events. We sought to evaluate the clinical and angiographic outcomes of patients who underwent bifurcation lesion provisional treatment in the BioNIR Ridaforolimus Eluting Coronary Stent System in Coronary Stenosis trial. A prospective, multicenter, 1:1 randomized trial was conducted to evaluate the safety and efficacy of ridaforolimus-eluting stents (RES) versus zotarolimus-eluting stents (ZES). Enrollment of bifurcation lesions treated with a provisional 1-stent technique was allowed. Bifurcation lesions were analyzed by an angiographic core laboratory. Outcomes were analyzed according to the presence of a bifurcation lesion treatment. Study population included 686 (35.8%) patients with and 1,228 (64.2%) patients without bifurcation lesion treatment. Procedural success was high and similar between groups. In 2 years, there was no difference in the rate of target lesion failure between the bifurcation and nonbifurcation groups (7.6% vs 7.3%, respectively, p = 0.81) regardless of the presence of side branch stenosis ≥50%. In 159 patients with angiographic follow-up, there was no difference in the rate of binary restenosis between groups (9.0% vs 9.2%, p = 0.96). Rates of target lesion failure at 1-year were similar with ZES and RES, and consistent in patients with and without bifurcation lesions (pinteraction = 0.61). In conclusion, patients with bifurcation lesions treated and a provisional strategy experienced similar outcomes as those with nonbifurcation lesions. RES performed as well as ZES in bifurcation and nonbifurcation lesions.


Assuntos
Doença da Artéria Coronariana/terapia , Estenose Coronária/terapia , Stents Farmacológicos , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Reestenose Coronária/epidemiologia , Estenose Coronária/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea , Estudos Prospectivos , Sirolimo/análogos & derivados
10.
J Am Coll Cardiol ; 75(16): 1882-1893, 2020 04 28.
Artigo em Inglês | MEDLINE | ID: mdl-32327098

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) use is increasing in patients with longer life expectancy, yet robust data on the durability of transcatheter heart valves (THVs) are limited. Redo-TAVR may play a key strategy in treating patients in whom THVs fail. OBJECTIVES: The authors sought to examine outcomes following redo-TAVR. METHODS: The Redo-TAVR registry collected data on consecutive patients who underwent redo-TAVR at 37 centers. Patients were classified as probable TAVR failure or probable THV failure if they presented within or beyond 1 year of their index TAVR, respectively. RESULTS: Among 63,876 TAVR procedures, 212 consecutive redo-TAVR procedures were identified (0.33%): 74 within and 138 beyond 1 year of the initial procedure. For these 2 groups, TAVR-to-redo-TAVR time was 68 (38 to 154) days and 5 (3 to 6) years. The indication for redo-TAVR was THV stenosis in 12 (16.2%) and 51 (37.0%) (p = 0.002) and regurgitation or combined stenosis-regurgitation in 62 (83.8%) and 86 (62.3%) (p = 0.028), respectively. Device success using VARC-2 criteria was achieved in 180 patients (85.1%); most failures were attributable to high residual gradients (14.1%) or regurgitation (8.9%). At 30-day and 1-year follow-up, residual gradients were 12.6 ± 7.5 mm Hg and 12.9 ± 9.0 mm Hg; valve area 1.63 ± 0.61 cm2 and 1.51 ± 0.57 cm2; and regurgitation ≤mild in 91% and 91%, respectively. Peri-procedural complication rates were low (3 stroke [1.4%], 7 valve malposition [3.3%], 2 coronary obstruction [0.9%], 20 new permanent pacemaker [9.6%], no mortality), and symptomatic improvement was substantial. Survival at 30 days was 94.6% and 98.5% (p = 0.101) and 83.6% and 88.3% (p = 0.335) at 1 year for patients presenting with early and late valve dysfunction, respectively. CONCLUSIONS: Redo-TAVR is a relatively safe and effective option for selected patients with valve dysfunction after TAVR. These results are important for applicability of TAVR in patients with long life expectancy in whom THV durability may be a concern.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Complicações Pós-Operatórias , Reoperação , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/epidemiologia , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Análise de Falha de Equipamento , Feminino , Saúde Global , Humanos , Masculino , Avaliação de Resultados em Cuidados de Saúde , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/cirurgia , Sistema de Registros/estatística & dados numéricos , Reoperação/instrumentação , Reoperação/métodos , Reoperação/estatística & dados numéricos , Análise de Sobrevida , Avaliação de Sintomas/estatística & dados numéricos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/métodos
11.
J Cardiovasc Comput Tomogr ; 14(5): 407-413, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32029384

RESUMO

BACKGROUND: CT measurement of supra-annular area (SA) has been proposed as an alternative to annular area (AA) for sizing of trancatheter valves in biscuspid aortic valves (BAV). This study examines the reproducibility of SA and AA measurements and their potential impact on downstream transcatheter heart valve sizing and clinical outcomes. METHODS: 44 consecutive patients (mean age: 73 ± 15 years, 57% male) undergoing CTA with subsequent SAPIEN 3 valve insertion for severe bicuspid aortic stenosis (AS) were included. AA was measured at the basal ring. SA was measured by generating a circle defined by the intercommisural distance. AA and SA were measured by 2 independent observers. Baseline characteristics, TAVR procedural data, and discharge echocardiography data were collected. RESULTS: The SA was significantly larger than the AA (562 ± 146mm2 vs. 518 ± 112mm2,p = 0.013). Interobserver agreement was high using both techniques (ICC AA = 0.98,p < 0.001; SA = 0.80,p < 0.001), but with narrower limits of agreement with AA measurements (mean difference (limits of agreement): AA = -3mm2 (22; 19), SA = -16mm2 (-92; 76)). AA-based device sizing demonstrated substantial agreement with final valve inserted (κ = 0.72,p < 0.001), while SA demonstrated fair agreement (κ = 0.40,p < 0.001). There was no difference in post TAVR gradients, paravalvular leakage or valve success between patients with concordant sizing between AA and SA, and those in whom SA would have suggested an alternate valve size. CONCLUSIONS: Supra-annular sizing is less reproducible than annular sizing, with no difference in procedural complication rates in patients in whom supra-annular sizing would have altered the device size used. These results suggest no role for supra-annular sizing in current clinical practice.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/anormalidades , Doenças das Valvas Cardíacas/cirurgia , Próteses Valvulares Cardíacas , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Doença da Válvula Aórtica Bicúspide , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Ecocardiografia , Feminino , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores , Valor Preditivo dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
12.
JACC Cardiovasc Interv ; 13(1): 86-93, 2020 01 13.
Artigo em Inglês | MEDLINE | ID: mdl-31918946

RESUMO

OBJECTIVES: This study sought to determine clinical outcomes between treatment groups over long-term follow-up. BACKGROUND: The safety and efficacy of a ridaforolimus-eluting stent (RES) was evaluated in the BIONICS (BioNIR Ridaforolimus-Eluting Coronary Stent System in Coronary Stenosis) and NIREUS (BioNIR Ridaforolimus Eluting Coronary Stent System [BioNIR] European Angiography Study) trials, demonstrating noninferiority of RES in comparison with a zotarolimus-eluting stent (ZES) regarding 1-year target lesion failure (TLF) and 6-month angiographic late lumen loss, respectively. METHODS: Patient-level data from the BIONICS (N = 1,919) and NIREUS (N = 302) randomized trials were pooled, and outcomes in patients implanted with RES and ZES compared. Broad inclusion criteria allowed enrollment of patients with acute coronary syndromes and complex lesions. The primary endpoint was the 2-year rate of TLF or clinically driven target lesion revascularization. RESULTS: A total of 2,221 patients (age 63.2 ± 10.3 years; 79.7% men) undergoing percutaneous coronary intervention with RES (n = 1,159) or ZES (n = 1,062) were included. Clinical and angiographic characteristics were similar between groups. At 2 years, the primary endpoint of TLF was similar among patients implanted with RES and ZES (7.0% vs. 7.2%; p = 0.94). Rates of target lesion revascularization (4.8% RES vs. 4.1% ZES; p = 0.41) and target vessel-related myocardial infarction (3.1% RES vs. 3.8% ZES; p = 0.52) did not differ between groups. The overall rate of stent thrombosis was also similar (0.5% RES vs. 0.9% ZES; p = 0.39). CONCLUSIONS: In a pooled analysis of 2 randomized trials, 2-year clinical outcomes were similar between patients undergoing percutaneous coronary intervention with RES and ZES. These results support the long-term safety and efficacy of RES for the treatment of a broad population of patients with coronary artery disease.


Assuntos
Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Sirolimo/análogos & derivados , Idoso , Fármacos Cardiovasculares/efeitos adversos , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Trombose Coronária/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Risco , Sirolimo/administração & dosagem , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
13.
Catheter Cardiovasc Interv ; 95(6): 1186-1192, 2020 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-31483555

RESUMO

OBJECTIVES: To perform clinical and echocardiographic follow-up beyond 1 year in consecutive patients with severe bicuspid aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR) with a current generation balloon-expandable valve. BACKGROUND: Treatment of bicuspid aortic valve disease with TAVR remains controversial and late follow-up data is still scarce. METHODS: We collected baseline characteristics, procedural data, 30-day and mid-term clinical follow-up findings from six centers in Europe and Canada from patients with bicuspid AS treated with TAVR using the SAPIEN 3 valve. RESULTS: Seventy-nine patients underwent TAVR. Mean age was 76 ± 9 years; median STS risk score for mortality was 3.8% (interquartile range 2.3-5.5%). Median follow-up was 390 days (interquartile range 138-739 days). Device success was achieved in 95% of patients. Postimplantation mean aortic gradient decreased from 50.2 ± 16.2 to 8.8 ± 4.4 mmHg and no patient had more than mild aortic regurgitation. At last follow-up, there was persistent good valve performance. At 30 days and 1 year, the rates of all-cause mortality were 3.8 and 7.7%, stroke 1.2 and 1.2%, and the rate of new pacemakers 18 and 18%. CONCLUSIONS: Our data confirm that treating patients with stenotic bicuspid aortic valves is safe, effective, and has favorable valve performance over time.


Assuntos
Estenose da Valva Aórtica/cirurgia , Doença da Válvula Aórtica Bicúspide/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Doença da Válvula Aórtica Bicúspide/diagnóstico por imagem , Doença da Válvula Aórtica Bicúspide/mortalidade , Doença da Válvula Aórtica Bicúspide/fisiopatologia , Canadá , Europa (Continente) , Feminino , Hemodinâmica , Humanos , Masculino , Recuperação de Função Fisiológica , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
14.
Catheter Cardiovasc Interv ; 95(1): 45-53, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31038290

RESUMO

OBJECTIVES: To demonstrate safety, feasibility and short-term clinical outcomes after transcatheter aortic valve-in-valve (ViV) implantation under local anesthesia without contrast aortography or echocardiographic guidance. BACKGROUND: Transcatheter ViV implantation is an emerging treatment modality for patients with degenerative surgical bioprostheses. Given the radiopaque properties of the surgical aortic valve (SAV) frame, ViV procedures can often be performed with fluoroscopic guidance alone. METHODS: ViV implantation was performed in 37 patients with SAV failure under local anesthesia without contrast aortography. Clinical and echocardiographic data were obtained at baseline, discharge, and 30 days. RESULTS: Mean age was 74 ± 10 years and STS predicted risk of mortality was 5.6 ± 2.4%. Mean transaortic gradient decreased from 39.4 ± 15.5 mmHg to 13 ± 6.3 mmHg at discharge (p < .001), and 20 ± 7.5 mmHg at 30 days (p < .001 compared to baseline), aortic valve area increased from 0.9 ± 0.3 cm2 to 1.2 ± 0.4 cm2 at 30 days (p = .007). No patient had more than mild aortic regurgitation. Hospital discharge occurred at a median of 2.6 ± 4.4 days. At 30-day follow-up there were no deaths, myocardial infarctions, strokes, repeat hospital admissions for heart failure, or renal failure. One patient (2.7%) required a new pacemaker. 93% of the patients were in New York Heart Association functional class I or II. CONCLUSIONS: Transcatheter aortic ViV implantation for selected patients with degenerative surgical bioprostheses under local anesthesia without aortography or echocardiographic guidance is feasible and safe.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Falha de Prótese , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Anestesia Local , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/mortalidade , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Estudos de Viabilidade , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
15.
JACC Cardiovasc Interv ; 11(24): 2467-2476, 2018 12 24.
Artigo em Inglês | MEDLINE | ID: mdl-30573057

RESUMO

OBJECTIVES: The authors sought to investigate the impact of diabetes mellitus (DM) on outcomes following contemporary drug-eluting stent (DES) implantation in the BIONICS (BioNIR Ridaforolimus Eluting Coronary Stent System in Coronary Stenosis) trial. BACKGROUND: Patients with DM are at increased risk for adverse events following percutaneous coronary intervention (PCI). METHODS: A prospective, multicenter, 1:1 randomized trial was conducted to evaluate in a noninferiority design the safety and efficacy of ridaforolimus-eluting stents versus zotarolimus-eluting stents among 1,919 patients undergoing PCI. Randomization was stratified to the presence of medically treated DM, and a pre-specified analysis compared outcomes according to the presence or absence of DM up to 2 years. RESULTS: The overall prevalence of DM was 29.1% (559 of 1,919). DM patients had higher body mass index, greater prevalence of hyperlipidemia and hypertension, and smaller reference vessel diameter. One-year target lesion failure (cardiac death, target vessel myocardial infarction, or ischemia-driven target lesion revascularization) was significantly higher among diabetic patients (7.8% vs. 4.2%; p = 0.002), mainly due to higher target lesion revascularization (4.5% vs. 2.0%; p = 0.002). Rates of cardiac death, myocardial infarction, and stent thrombosis did not statistically vary. Among 158 patients undergoing 13-month angiographic follow-up, restenosis rates were 3 times higher in diabetic patients compared with nondiabetic patients (15.2% vs. 4.7%; p = 0.01). Clinical and angiographic outcomes were similar between ridaforolimus-eluting stent- and zotarolimus-eluting stent-treated patients. CONCLUSIONS: Despite advances in interventional therapies, and the implementation of new-generation DES, diabetic patients still have worse angiographic and clinical outcomes compared with nondiabetic patients undergoing PCI.


Assuntos
Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Estenose Coronária/terapia , Diabetes Mellitus/epidemiologia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Sirolimo/análogos & derivados , Idoso , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Reestenose Coronária/epidemiologia , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/mortalidade , Trombose Coronária/epidemiologia , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/epidemiologia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Prevalência , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Método Simples-Cego , Sirolimo/administração & dosagem , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
16.
Front Cardiovasc Med ; 5: 140, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30374442

RESUMO

Background: Tricuspid regurgitation (TR) is common and undertreated as the risk of surgery is high in this patient population. Transcatheter devices offer treatment with a lower procedural risk. The FORMA Tricuspid Valve Therapy system (Edwards Lifesciences) will be reviewed here. Device Description: The system combines a spacer placed in the regurgitant orifice and a rail, over which the spacer is delivered, that is anchored to the endocardial surface of the RV. The spacer provides a surface for leaflet coaptation. Outcomes: Eighteen compassionate care patients and 29 patients included in the US EFS trial are reviewed. Patients were elderly (76 years) and high risk (Euroscore 2 was 9.0 and 8.1%, respectively). There were 2 procedural failures in both groups. Mortality at 30 days was 0% in the compassionate group and 7% in the EFS trial. TR was reduced in both groups; 2D/3D EROA 2.1 ± 1.8 to 1.1 ± 0.9 cm2 in the EFS trial and vena contracta width 12.1 ± 3.3 to 7.1 ± 2.2 mm. Symptomatic improvement was seen in both groups; the proportion of patients in NYHA class III/IV decreased from 84 to 28% at 30 days in the EFS group, and from 94 to 21% at 1 year, in the compassionate group. Conclusions: Reduction of TR with FORMA system is feasible and sustained. Despite residual TR post-procedure, the significant relative reduction in TR severity contributes to substantial clinical improvements in patients with a FORMA device in place.

17.
EuroIntervention ; 14(1): 86-93, 2018 05 20.
Artigo em Inglês | MEDLINE | ID: mdl-29537374

RESUMO

AIMS: The aim of this study was to evaluate the efficacy and safety of the BioNIR stent compared with the Resolute Integrity stent for the treatment of coronary artery disease. METHODS AND RESULTS: This first-in-human, multicentre, single-blind randomised non-inferiority trial was performed in Europe and Israel. Patients with stable coronary artery disease or acute coronary syndromes were randomly assigned to treatment with BioNIR or Resolute Integrity stents in a 2:1 fashion. The primary endpoint was angiographic in-stent late lumen loss (LLL) at six months. Three hundred and two patients were randomised, of whom 261 (86.0%) underwent six-month angiographic follow-up. The BioNIR stent was non-inferior to the Resolute Integrity stent for the primary endpoint of in-stent LLL at six months (0.04±0.30 mm vs. 0.03±0.31 mm, respectively, pnoninferiority<0.0001). At 12-month follow-up, target lesion failure occurred in 3.4% in the BioNIR group and 5.9% in the Resolute Integrity group (p=0.22). Rates of MACE were similar between the BioNIR and Resolute Integrity groups (4.3% vs. 5.9%, respectively, p=0.45). CONCLUSIONS: The BioNIR stent was non-inferior to the Resolute Integrity stent for the primary endpoint of angiographic in-stent LLL at six months. Clinical outcomes at one year were comparable between the two groups.


Assuntos
Doença da Artéria Coronariana/terapia , Reestenose Coronária/terapia , Stents Farmacológicos , Sirolimo/análogos & derivados , Adulto , Idoso , Idoso de 80 Anos ou mais , Stents Farmacológicos/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/terapia , Intervenção Coronária Percutânea/métodos , Estudos Prospectivos , Sirolimo/uso terapêutico , Resultado do Tratamento
18.
Catheter Cardiovasc Interv ; 91(7): E86-E89, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-28296021

RESUMO

Apicoaortic conduit surgery is an option for treating severe aortic stenosis. The implanted conduit valve may eventually fail and require replacement; this is usually performed by repeat surgery. Treating the conduit valve with a standard transcatheter heart valve is an option that has become feasible in recent years. We describe a case of a failed 23 mm CE bioprosthesis that was successfully treated with a 23 mm Sapien XT valve as a valve-in-valve procedure. © 2017 Wiley Periodicals, Inc.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Valvuloplastia com Balão , Ecocardiografia Doppler em Cores , Ecocardiografia Transesofagiana , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Falha de Prótese , Recuperação de Função Fisiológica , Tomografia Computadorizada por Raios X , Resultado do Tratamento
19.
Circulation ; 136(14): 1304-1314, 2017 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-28794001

RESUMO

BACKGROUND: The safety and efficacy of a novel cobalt alloy-based coronary stent with a durable elastomeric polymer eluting the antiproliferative agent ridaforolimus for treatment of patients with coronary artery disease is undetermined. METHODS: A prospective, international 1:1 randomized trial was conducted to evaluate in a noninferiority design the relative safety and efficacy of ridaforolimus-eluting stents (RESs) and slow-release zotarolimus-eluting stents among 1919 patients undergoing percutaneous coronary intervention at 76 centers. Inclusion criteria allowed enrollment of patients with recent myocardial infarction, total occlusions, bifurcations lesions, and other complex conditions. RESULTS: Baseline clinical and angiographic characteristics were similar between the groups. Overall, mean age was 63.4 years, 32.5% had diabetes mellitus, and 39.7% presented with acute coronary syndromes. At 12 months, the primary end point of target lesion failure (composite of cardiac death, target vessel-related myocardial infarction, and target lesion revascularization) was 5.4% for both devices (upper bound of 1-sided 95% confidence interval 1.8%, Pnoninferiority=0.001). Definite/probable stent thrombosis rates were low in both groups (0.4% RES versus 0.6% zotarolimus-eluting stent, P=0.75); 13-month angiographic in-stent late lumen loss was 0.22±0.41 mm and 0.23±0.39 mm (Pnoninferiority=0.004) for the RES and zotarolimus-eluting stent groups, respectively, and intravascular ultrasound percent neointimal hyperplasia was 8.10±5.81 and 8.85±7.77, respectively (Pnoninferiority=0.01). CONCLUSIONS: In the present trial, which allowed broad inclusion criteria, the novel RESs met the prespecified criteria for noninferiority compared with zotarolimus-eluting stents for the primary end point of target lesion failure at 12 months and had similar measures of late lumen loss. These findings support the safety and efficacy of RESs in patients who are representative of clinical practice. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT01995487.


Assuntos
Doença da Artéria Coronariana/terapia , Stents Farmacológicos/normas , Intervenção Coronária Percutânea/métodos , Sirolimo/análogos & derivados , Feminino , Humanos , Masculino , Estudos Prospectivos , Sirolimo/administração & dosagem , Sirolimo/farmacologia , Sirolimo/uso terapêutico
20.
J Am Coll Cardiol ; 69(21): 2579-2589, 2017 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-28330793

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is being increasingly performed in patients with bicuspid aortic valve stenosis (AS). OBJECTIVES: This study sought to compare the procedural and clinical outcomes in patients with bicuspid versus tricuspid AS from the Bicuspid AS TAVR multicenter registry. METHODS: Outcomes of 561 patients with bicuspid AS and 4,546 patients with tricuspid AS were compared after propensity score matching, assembling 546 pairs of patients with similar baseline characteristics. Procedural and clinical outcomes were recorded according to Valve Academic Research Consortium-2 criteria. RESULTS: Compared with patients with tricuspid AS, patients with bicuspid AS had more frequent conversion to surgery (2.0% vs. 0.2%; p = 0.006) and a significantly lower device success rate (85.3% vs. 91.4%; p = 0.002). Early-generation devices were implanted in 320 patients with bicuspid and 321 patients with tricuspid AS, whereas new-generation devices were implanted in 226 and 225 patients with bicuspid and tricuspid AS, respectively. Within the group receiving early-generation devices, bicuspid AS had more frequent aortic root injury (4.5% vs. 0.0%; p = 0.015) when receiving the balloon-expanding device, and moderate-to-severe paravalvular leak (19.4% vs. 10.5%; p = 0.02) when receiving the self-expanding device. Among patients with new-generation devices, however, procedural results were comparable across different prostheses. The cumulative all-cause mortality rates at 2 years were comparable between bicuspid and tricuspid AS (17.2% vs. 19.4%; p = 0.28). CONCLUSIONS: Compared with tricuspid AS, TAVR in bicuspid AS was associated with a similar prognosis, but lower device success rate. Procedural differences were observed in patients treated with the early-generation devices, whereas no differences were observed with the new-generation devices.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/anormalidades , Doenças das Valvas Cardíacas/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/métodos , Valva Tricúspide/cirurgia , Idoso , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Doença da Válvula Aórtica Bicúspide , Feminino , Saúde Global , Humanos , Masculino , Estudos Retrospectivos , Taxa de Sobrevida/tendências , Resultado do Tratamento , Valva Tricúspide/anormalidades
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...