Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nat Commun ; 13(1): 6180, 2022 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-36261453

RESUMO

The CAST-CAPP axion haloscope, operating at CERN inside the CAST dipole magnet, has searched for axions in the 19.74 µeV to 22.47 µeV mass range. The detection concept follows the Sikivie haloscope principle, where Dark Matter axions convert into photons within a resonator immersed in a magnetic field. The CAST-CAPP resonator is an array of four individual rectangular cavities inserted in a strong dipole magnet, phase-matched to maximize the detection sensitivity. Here we report on the data acquired for 4124 h from 2019 to 2021. Each cavity is equipped with a fast frequency tuning mechanism of 10 MHz/ min between 4.774 GHz and 5.434 GHz. In the present work, we exclude axion-photon couplings for virialized galactic axions down to gaγγ = 8 × 10-14 GeV-1 at the 90% confidence level. The here implemented phase-matching technique also allows for future large-scale upgrades.

2.
Rev Sci Instrum ; 89(10): 10G113, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399826

RESUMO

Recent breakthroughs in the fabrication of small-radii Wolter optics for astrophysics allow high energy density facilities to consider such optics as novel x-ray diagnostics at photon energies of 15-50 keV. Recently, the Lawrence Livermore National Laboratory, Sandia National Laboratories (SNL), the Smithsonian Astrophysical Observatory, and the NASA Marshall Space Flight Center jointly developed and fabricated the first custom Wolter microscope for implementation in SNL's Z machine with optimized sensitivity at 17.5 keV. To achieve spatial resolution of order 100-200 microns over a field of view of 5 × 5 × 5 mm3 with high throughput and narrow energy bandpass, the geometry of the optic and its multilayer required careful design and optimization. While the geometry mainly influences resolution and the field of view of the diagnostic, the mirror coating determines the spectral response and throughput. Here we outline the details of the design and fabrication process for the first multilayer-coated Wolter I optic for SNL's Z machine (Z Wolter), including its W/Si multilayer, and present results of raytrace simulations completed to predict and verify the performance of the optic.

3.
Rev Sci Instrum ; 89(10): 10G115, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399891

RESUMO

A new Wolter x-ray imager has been developed for the Z machine to study the emission of warm (>15 keV) x-ray sources. A Wolter optic has been adapted from observational astronomy and medical imaging, which uses curved x-ray mirrors to form a 2D image of a source with 5 × 5 × 5 mm3 field-of-view and measured 60-300-µm resolution on-axis. The mirrors consist of a multilayer that create a narrow bandpass around the Mo Kα lines at 17.5 keV. We provide an overview of the instrument design and measured imaging performance. In addition, we present the first data from the instrument of a Mo wire array z-pinch on the Z machine, demonstrating improvements in spatial resolution and a 350-4100× increase in the signal over previous pinhole imaging techniques.

4.
Appl Opt ; 55(16): 4285-92, 2016 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-27411177

RESUMO

The use of a grazing incidence optic to selectively reflect K-shell fluorescence emission and isotope-specific lines from special nuclear materials is a highly desirable nondestructive analysis method for use in reprocessing fuel environments. Preliminary measurements have been performed, and a simulation suite has been developed to give insight into the design of the x ray optics system as a function of the source emission, multilayer coating characteristics, and general experimental configurations. The experimental results are compared to the predictions from our simulation toolkit to illustrate the ray-tracing capability and explore the effect of modified optics in future measurement campaigns.

5.
Science ; 348(6235): 670-1, 2015 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-25954004

RESUMO

In core-collapse supernovae, titanium-44 ((44)Ti) is produced in the innermost ejecta, in the layer of material directly on top of the newly formed compact object. As such, it provides a direct probe of the supernova engine. Observations of supernova 1987A (SN1987A) have resolved the 67.87- and 78.32-kilo-electron volt emission lines from decay of (44)Ti produced in the supernova explosion. These lines are narrow and redshifted with a Doppler velocity of ~700 kilometers per second, direct evidence of large-scale asymmetry in the explosion.

6.
Rev Sci Instrum ; 86(1): 013110, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25638075

RESUMO

A multilayer-based optic was tested for use as an X-ray diagnostic on a laser-plasma experiment. The multilayer optic was employed to selectively pass X-rays between 55 and 100 keV. An order of magnitude improvement in signal-to-noise ratio is achieved compared to a transmission crystal spectrometer. A multilayer response model, taking into account the source size and spectral content, is constructed and the outlook for application above 500 keV is briefly discussed. LLNL-JRNL-664311.

7.
Nature ; 506(7488): 339-42, 2014 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-24553239

RESUMO

Asymmetry is required by most numerical simulations of stellar core-collapse explosions, but the form it takes differs significantly among models. The spatial distribution of radioactive (44)Ti, synthesized in an exploding star near the boundary between material falling back onto the collapsing core and that ejected into the surrounding medium, directly probes the explosion asymmetries. Cassiopeia A is a young, nearby, core-collapse remnant from which (44)Ti emission has previously been detected but not imaged. Asymmetries in the explosion have been indirectly inferred from a high ratio of observed (44)Ti emission to estimated (56)Ni emission, from optical light echoes, and from jet-like features seen in the X-ray and optical ejecta. Here we report spatial maps and spectral properties of the (44)Ti in Cassiopeia A. This may explain the unexpected lack of correlation between the (44)Ti and iron X-ray emission, the latter being visible only in shock-heated material. The observed spatial distribution rules out symmetric explosions even with a high level of convective mixing, as well as highly asymmetric bipolar explosions resulting from a fast-rotating progenitor. Instead, these observations provide strong evidence for the development of low-mode convective instabilities in core-collapse supernovae.

8.
Rev Sci Instrum ; 83(10): 10E525, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23127032

RESUMO

Hohlraums are employed at the national ignition facility to convert laser energy into a thermal x-radiation drive, which implodes a fusion capsule, thus compressing the fuel. The x-radiation drive is measured with a low spectral resolution, time-resolved x-ray spectrometer, which views the region around the hohlraum's laser entrance hole. This measurement has no spatial resolution. To convert this to the drive inside the hohlraum, the size of the hohlraum's opening ("clear aperture") and fraction of the measured x-radiation, which comes from this opening, must be known. The size of the clear aperture is measured with the time integrated static x-ray imager (SXI). A soft x-ray imaging channel has been added to the SXI to measure the fraction of x-radiation emitted from inside the clear aperture. A multilayer mirror plus filter selects an x-ray band centered at 870 eV, near the peak of the x-ray spectrum of a 300 eV blackbody. Results from this channel and corrections to the x-radiation drive are discussed.

9.
Rev Sci Instrum ; 81(10): 10E538, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21034065

RESUMO

The static x-ray imager at the National Ignition Facility is a pinhole camera using a CCD detector to obtain images of Hohlraum wall x-ray drive illumination patterns seen through the laser entrance hole (LEH). Carefully chosen filters, combined with the CCD response, allow recording images in the x-ray range of 3-5 keV with 60 µm spatial resolution. The routines used to obtain the apparent size of the backlit LEH and the location and intensity of beam spots are discussed and compared to predictions. A new soft x-ray channel centered at 870 eV (near the x-ray peak of a 300 eV temperature ignition Hohlraum) is discussed.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...