Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J AOAC Int ; 103(6): 1619-1624, 2020 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-33112388

RESUMO

BACKGROUND: Lycopene has been the object of considerable research attention recently, and the effects of the intake of lycopene, or of tomato products, have been studied in various ways. In Japan, interest in the health-promoting function of food components has increased. OBJECTIVE: Developing a method to determine lycopene contents in tomato that meets the Japanese Agricultural Standard (JAS). METHOD: In the proposed JAS method, the test sample consists of fresh tomatoes; a hexane-acetone mixture is utilized as the extraction solvent. A collaborative study was conducted to evaluate the interlaboratory performance of the method. RESULTS: Ten laboratories participated and analyzed six test materials characterized by a lycopene content between 39 and 170 mg/kg as blind duplicates. After removing statistical outliers, RSDr ranged from 1.2 to 3.0% and RSDR ranged from 2.4 to 4.2%. The HorRat values were calculated and found to be in the 0.26-0.49 range. CONCLUSIONS: The method for determining the lycopene content in tomato was evaluated by means of a collaborative study, and the reproducibility of this method was found to be acceptable. HIGHLIGHTS: Intended for standardization in Japan, a method to determine lycopene content in tomato has been developed and shown to have acceptable precision in a collaborative study.


Assuntos
Licopeno , Solanum lycopersicum , Japão , Licopeno/análise , Reprodutibilidade dos Testes , Espectrofotometria
2.
J AOAC Int ; 89(5): 1341-6, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-17042185

RESUMO

An interlaboratory study was performed to evaluate the method for determining the acid value of instant noodles, based on the Japanese Agricultural Standard (JAS), with extraction of lipid using petroleum ether at a volume of 100 mL to the test portion of 25 g. Thirteen laboratories participated and analyzed 5 test samples as blind duplicates. Statistical treatment revealed that the repeatability (RSDr) of acid value was <6.5%, and the reproducibility (RSDR) of acid value was <9.6%. The HorRat values (RSDR/predicted RSDR) were 1.2-1.8, where the RSDR and the predicted RSDR were obtained in terms of free fatty acids in the noodles per unit weight, using the equation [acid value = percent free fatty acids (as oleic) x 1.99] and the extracted lipid contents. This method was shown to have acceptable precision by the present study.


Assuntos
Ácidos/análise , Análise de Alimentos/métodos , Alcanos , Análise de Alimentos/normas , Análise de Alimentos/estatística & dados numéricos , Japão , Laboratórios , Lipídeos/química , Lipídeos/isolamento & purificação , Reprodutibilidade dos Testes , Triticum/química
3.
J AOAC Int ; 89(6): 1585-90, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-17225606

RESUMO

Determination of the moisture content of instant noodles, currently under discussion by the Codex Alimentarius Commission (CAC) requires 2 methods: one for fried noodles and the other for nonfried noodles. The method to determine the moisture content of fried noodles by drying at 105 degrees C for 2 h used in the Japanese Agricultural Standard (JAS) system of Japan can be applied to this purpose. In the present study, the JAS method for fried noodles was modified to be suitable for nonfried noodles by extending the drying time to 4 h. An interlaboratory study was conducted to evaluate interlaboratory performance statistics for these 2 methods. Ten participating laboratories each analyzed 5 test materials of fried and nonfried noodles as blind duplicates. After removal of outliers statistically, the repeatability (RSDr) and the reproducibility (RSD(R)) of these methods were 1.6-2.6 and 3.9-4.8% for fried noodles, and 0.3-1.5 and 1.3-2.9% for nonfried noodles, respectively.


Assuntos
Análise de Alimentos , Culinária , Fabaceae/química , Umidade , Reprodutibilidade dos Testes , Amido/análise , Água/análise
4.
Anal Sci ; 21(9): 1129-32, 2005 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16363486

RESUMO

The objective of this collaborative study was to evaluate the proposed method for determining the total nitrogen in soy sauce by the Kjeldahl method submitted to the Codex Alimentarius Commission for endorsement in accordance with the protocol for the design, conduct, and interpretation of method-performance studies. The digestive conditions of the proposed method are the addition of 10 mL of H2SO4, 10 g (8 g by using a block digester) of K2SO4, and 1 mL of 20% CuSO4 x 5H2O and 80 min boiling period after the liquid is cleared by a heating device. Seventeen laboratories participated, analyzing five soy sauce samples as blind duplicates. Since the volume sampling method used in the JAS (Japanese Agricultural Standard) method showed lower accuracy of data because of the density of soy sauce, the method of sampling by weight was adopted as the proposed method. The total amount of outlier data was within acceptable limits for method-performance studies (< or = 22.2%). Lysine and ammonium sulfate recoveries for all laboratories were > or = 98% and > or = 99% respectively. The RSDr (repeatability relative standard deviation) values ranged from 0.4 to 1.3%, and the RSDR (reproducibility relative standard deviation) values were from 0.8 to 1.9%. HORRAT (RSDR/predicted RSDR) for the reproducibility showed 0.2 to 0.4, indicating acceptable precision of the method and excellent analytical performance.


Assuntos
Análise de Alimentos/métodos , Nitrogênio/análise , Alimentos de Soja/análise , Reprodutibilidade dos Testes , Alimentos de Soja/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...