Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 81
Filtrar
1.
Radiol Med ; 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38689182

RESUMO

PURPOSE: Artifacts caused by metallic implants remain a challenge in computed tomography (CT). We investigated the impact of photon-counting detector computed tomography (PCD-CT) for artifact reduction in patients with orthopedic implants with respect to image quality and diagnostic confidence using different artifact reduction approaches. MATERIAL AND METHODS: In this prospective study, consecutive patients with orthopedic implants underwent PCD-CT imaging of the implant area. Four series were reconstructed for each patient (clinical standard reconstruction [PCD-CTStd], monoenergetic images at 140 keV [PCD-CT140keV], iterative metal artifact reduction (iMAR) corrected [PCD-CTiMAR], combination of iMAR and 140 keV monoenergetic [PCD-CT140keV+iMAR]). Subsequently, three radiologists evaluated the reconstructions in a random and blinded manner for image quality, artifact severity, anatomy delineation (adjacent and distant), and diagnostic confidence using a 5-point Likert scale (5 = excellent). In addition, the coefficient of variation [CV] and the relative quantitative artifact reduction potential were obtained as objective measures. RESULTS: We enrolled 39 patients with a mean age of 67.3 ± 13.2 years (51%; n = 20 male) and a mean BMI of 26.1 ± 4 kg/m2. All image quality measures and diagnostic confidence were significantly higher for the iMAR vs. non-iMAR reconstructions (all p < 0.001). No significant effect of the different artifact reduction approaches on CV was observed (p = 0.26). The quantitative analysis indicated the most effective artifact reduction for the iMAR reconstructions, which was higher than PCD-CT140keV (p < 0.001). CONCLUSION: PCD-CT allows for effective metal artifact reduction in patients with orthopedic implants, resulting in superior image quality and diagnostic confidence with the potential to improve patient management and clinical decision making.

2.
Neuroradiology ; 66(5): 749-759, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38498208

RESUMO

PURPOSE: CT perfusion of the brain is a powerful tool in stroke imaging, though the radiation dose is rather high. Several strategies for dose reduction have been proposed, including increasing the intervals between the dynamic scans. We determined the impact of temporal resolution on perfusion metrics, therapy decision, and radiation dose reduction in brain CT perfusion from a large dataset of patients with suspected stroke. METHODS: We retrospectively included 3555 perfusion scans from our clinical routine dataset. All cases were processed using the perfusion software VEOcore with a standard sampling of 1.5 s, as well as simulated reduced temporal resolution of 3.0, 4.5, and 6.0 s by leaving out respective time points. The resulting perfusion maps and calculated volumes of infarct core and mismatch were compared quantitatively. Finally, hypothetical decisions for mechanical thrombectomy following the DEFUSE-3 criteria were compared. RESULTS: The agreement between calculated volumes for core (ICC = 0.99, 0.99, and 0.98) and hypoperfusion (ICC = 0.99, 0.99, and 0.97) was excellent for all temporal sampling schemes. Of the 1226 cases with vascular occlusion, 14 (1%) for 3.0 s sampling, 23 (2%) for 4.5 s sampling, and 63 (5%) for 6.0 s sampling would have been treated differently if the DEFUSE-3 criteria had been applied. Reduction of temporal resolution to 3.0 s, 4.5 s, and 6.0 s reduced the radiation dose by a factor of 2, 3, or 4. CONCLUSION: Reducing the temporal sampling of brain perfusion CT has only a minor impact on image quality and treatment decision, but significantly reduces the radiation dose to that of standard non-contrast CT.


Assuntos
Isquemia Encefálica , Acidente Vascular Cerebral , Humanos , Estudos Retrospectivos , Redução da Medicação , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/terapia , Encéfalo/diagnóstico por imagem , Encéfalo/irrigação sanguínea , Tomografia Computadorizada por Raios X/métodos , Isquemia Encefálica/terapia , Perfusão , Imagem de Perfusão/métodos
3.
Ann Phys Rehabil Med ; 67(4): 101827, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38479249

RESUMO

BACKGROUND: At the completion of formal rehabilitation after anterior cruciate ligament reconstruction, functional capacity is only restored in a small proportion of affected individuals. Therefore, the end of formal rehabilitation is not the end of functional rehabilitation. OBJECTIVE: To compare adherence to and effectiveness of a late-stage rehabilitation programme with usual care after anterior cruciate ligament (ACL) reconstruction. METHODS: This prospective, double-blind, multicentre, parallel group, randomised controlled trial, included people aged 18 to 35 years after formal rehabilitation completion (mean [SD] 241 [92] days post-reconstruction). Participants were block-randomised to a 5-month neuromuscular performance intervention (Stop-X group) or usual care (medically prescribed standard physiotherapy, individual formal rehabilitation, home-exercises). All outcomes were measured once/month. Primary outcome was the normalised knee separation distance on landing after drop jump. Baseline-adjusted linear mixed models were calculated. RESULTS: In total, 112 participants (Stop-X: 57; Usual care: 55,) were analysed. Initially, mean (SD) intervention frequency (units/week) was higher in the Stop-X than the Usual care group: 2.65 (0.96) versus 2.48 (1.14) units/week in the first and 2.28 (1.02) versus 2.14 (1.31) units/week in the second month. No between-group*time(*baseline)-differences were found for the primary outcome. Between-group*time-effects favoured the Stop-X-group at 2 months (fewer self-reported knee problems during sport, KOOS-SPORT) (estimate = 64.3, 95 % CI 24.4-104.3 for the Stop-X), more confidence to return to sport (ACL-RSI) (62.4, 10.7-114.2), fewer pain-associated knee problems (KOOS-PAIN) (82.8, 36.0-129.6), improved everyday activity abilities (KOOS-ADL) (71.1, 6.4-135.7), and improved limb symmetry index in the front hop for distance at 3 and 4 months (0.34, 0.10-0.57; 0.31, 0.08-0.54). No between-group*time-effects occurred for kinesiophobia, symptom-associated knee problems or balance hops performance. At the end of the intervention, 79 % of the Stop-X and 70 % of the Usual care participants (p < 0.05) had successfully returned to their pre-injury sport type and level. CONCLUSIONS: The Stop-X intervention was slightly superior to usual care as part of late-stage rehabilitation after ACL-reconstruction. The small benefit might justify its use after formal rehabilitation completion.


Assuntos
Reconstrução do Ligamento Cruzado Anterior , Humanos , Reconstrução do Ligamento Cruzado Anterior/reabilitação , Masculino , Feminino , Adulto , Método Duplo-Cego , Adulto Jovem , Estudos Prospectivos , Adolescente , Lesões do Ligamento Cruzado Anterior/cirurgia , Lesões do Ligamento Cruzado Anterior/reabilitação , Resultado do Tratamento , Terapia por Exercício/métodos , Modalidades de Fisioterapia , Recuperação de Função Fisiológica
4.
Radiol Med ; 129(5): 669-676, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38512614

RESUMO

PURPOSE: To investigate the value of photon-counting detector CT (PCD-CT) derived virtual non-contrast (VNC) reconstructions to identify renal cysts in comparison with conventional dual-energy integrating detector (DE EID) CT-derived VNC reconstructions. MATERIAL AND METHODS: We prospectively enrolled consecutive patients with simple renal cysts (Bosniak classification-Version 2019, density ≤ 20 HU and/or enhancement ≤ 20 HU) who underwent multiphase (non-contrast, arterial, portal venous phase) PCD-CT and for whom non-contrast and portal venous phase DE EID-CT was available. Subsequently, VNC reconstructions were calculated for all contrast phases and density as well as contrast enhancement within the cysts were measured and compared. MRI and/or ultrasound served as reference standards for lesion classification. RESULTS: 19 patients (1 cyst per patient; age 69.5 ± 10.7 years; 17 [89.5%] male) were included. Density measurements on PCD-CT non-contrast and VNC reconstructions (arterial and portal venous phase) revealed no significant effect on HU values (p = 0.301). In contrast, a significant difference between non-contrast vs. VNC images was found for DE EID-CT (p = 0.02). For PCD-CT, enhancement for VNC reconstructions was < 20 HU for all evaluated cysts. DE EID-CT measurements revealed an enhancement of > 20 HU in five lesions (26.3%) using the VNC reconstructions, which was not seen with the non-contrast images. CONCLUSION: PCD-CT-derived VNC images allow for reliable and accurate characterization of simple cystic renal lesions similar to non-contrast scans whereas VNC images calculated from DE EID-CT resulted in substantial false characterization. Thus, PCD-CT-derived VNC images may substitute for non-contrast images and reduce radiation dose and follow-up imaging.


Assuntos
Doenças Renais Císticas , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Idoso , Estudos Prospectivos , Tomografia Computadorizada por Raios X/métodos , Doenças Renais Císticas/diagnóstico por imagem , Pessoa de Meia-Idade , Fótons , Idoso de 80 Anos ou mais , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos
5.
Clin Pract ; 14(1): 132-147, 2024 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-38248435

RESUMO

BACKGROUND: Cardiovascular diseases and arrhythmias are medical conditions that increase with age and are associated with significant morbidities and mortality. The aim of the present study was to investigate the prevalence of arrhythmias and clinical associations in the collective of older adults receiving comprehensive geriatric care (CGC). METHODS: Holter ECG monitoring (HECG) of older patients hospitalized for CGC was analyzed. The prevalence of arrhythmias and the associations between the presence of arrhythmias, patients' characteristics and the functional status regarding basic activities of daily living (assessed by the Barthel index (BI)), walking ability (assessed by the timed up and go test (TUG)), and balance and gait (assessed by the Tinetti balance and gait test (TBGT)) were examined. RESULTS: In the presented study, 626 patients were included (mean age: 83.9 ± 6.6 years, 67.7% were female). The most common arrhythmias detected in HECG were premature ventricular contractions (87.2%), premature atrial contractions (71.7%), and atrial fibrillation (22.7%). Atrial flutter was found in 1.0%, paroxysmal supraventricular tachycardia in 5.8%, non-sustained ventricular tachycardia in 12.5%, first-degree AV block in 0.8%, second-degree AV block type Mobitz I in 0.8%, second-degree AV block type Mobitz II in 0.3%, pause > 2.5 s any cause in 3.5%, and pause > 3 s any cause in 1.6% of the cases. Premature atrial contractions were associated with the female sex (74.8% vs. 65.3%, p = 0.018), whereas in male patients, the following arrhythmias were more common: premature ventricular contractions (91.6% vs. 85.1%, p = 0.029), ventricular bigeminus (8.4% vs. 3.8%, p = 0.021), and non-sustained ventricular tachycardia (17.3% vs. 10.1%, p = 0.014). Atrial fibrillation detected in HECG was more frequent in patients at high risk of falls, indicated by their TBGT score ≤ 18 (24.7% vs. 12.0%, p = 0.006), and premature ventricular contractions were more common in patients unable to walk (TUG score 5) compared to those with largely independent mobility (TUG score 1 or 2) (88.0% vs. 75.0%, p = 0.023). In a logistic regression analysis, atrial fibrillation detected in HECG was identified as a risk factor for a high risk of falls (odds ratio (OR): 2.35, 95% confidence interval (CI): 1.23-4.46). CONCLUSION: In our study, investigation of HECG of older adults hospitalized for CGC revealed that premature atrial contractions, premature ventricular contractions, and atrial fibrillation were the most common arrhythmias. Premature atrial contractions were found to be more frequent in female patients, while male patients were more prone to premature ventricular contractions. In the investigated population, atrial fibrillation emerged as a risk factor associated with a high risk of falls.

6.
Knee Surg Sports Traumatol Arthrosc ; 32(2): 223-234, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38293720

RESUMO

PURPOSE: The aim of this consensus project was to give recommendations regarding surgical treatment of the anterior cruciate ligament (ACL) injured patient. METHODS: For this consensus process, an expert, steering and rating group was formed. In an initial online meeting, the steering group, together with the expert group, formed various key topic complexes for which multiple questions were formulated. For each key topic, a structured literature search was performed by the steering group. The results of the literature review were sent to the rating group with the option to give anonymous comments until a final consensus voting was performed. Sufficient consensus was defined as 80% agreement. RESULTS: During this consensus process, 30 topics regarding the surgical management and technique of ACL reconstruction were identified. The literature search for each key question resulted in 30 final statements. Of these 30 final statements, all achieved consensus. CONCLUSIONS: This consensus process has shown that surgical treatment of ACL injury is a complex process. Various surgical factors influence patient outcomes. The proposed treatment algorithm can be used as a decision aid for the surgeon. LEVEL OF EVIDENCE: Level V.


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Humanos , Algoritmos , Ligamento Cruzado Anterior/cirurgia , Lesões do Ligamento Cruzado Anterior/cirurgia , Reconstrução do Ligamento Cruzado Anterior/métodos , Consenso
7.
J Sport Rehabil ; 33(2): 88-98, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38176405

RESUMO

OBJECTIVE: To rate athletes' functional ability and return to sport (RTS) success at the end of their individual, formal, medically prescribed rehabilitation after anterior anterior cruciate ligament (ACL) reconstruction. METHODS: In our prospective multicenter cohort study, 88 (42 females) adults aged 18-35 years after acute unilateral ACL rupture and subsequent hamstring grafting were included. All patients were prospectively monitored during their rehabilitation and RTS process until the end of their formal rehabilitation and RTS release. As outcome measures, functional hop and jump tests (front hop, balance hops, and drop jump screening test) and self-report outcomes (Knee Injury and Osteoarthritis Outcome Score, ACL-RTS after injury) were assessed. Literature-based cut-off values were selected to rate each performance as fulfilled or not. RESULTS: At 7.5 months (SD 2.3 months) after surgery, the percentage of participants meeting the functional thresholds ranged from 4% (Knee Injury and Osteoarthritis Outcome Score SPORT) and over 44% (ACL-RTS after injury sum score) to 59% (Knee Injury and Osteoarthritis Outcome Score activities of all daily living) in the self-report and from 29% (Balance side hop) to 69% (normalized knee separation distance) in performance testing. Only 4% fulfilled all the cut-offs, while 45% returned to the same type and level of sport. Participants who successfully returned to their previous sport (type and level) were more likely to be "over-cut-off-performers." CONCLUSIONS: The low share of the athletes who fulfilled the functional RTS criteria highlights the importance of continuing the rehabilitation measures after the formal completion to assess the need for and success of, inter alia, secondary-preventive therapies.


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Traumatismos do Joelho , Osteoartrite , Adulto , Feminino , Humanos , Estudos de Coortes , Estudos Prospectivos , Recuperação de Função Fisiológica , Músculo Quadríceps , Lesões do Ligamento Cruzado Anterior/cirurgia , Volta ao Esporte , Traumatismos do Joelho/cirurgia , Reconstrução do Ligamento Cruzado Anterior/reabilitação , Osteoartrite/cirurgia
8.
Arch Phys Med Rehabil ; 105(4): 710-716, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38016495

RESUMO

OBJECTIVE: To investigate the feasibility, reliability, and validity of the Modified forward hop (MFH) test in participants after ACL reconstruction (ACLR). DESIGN: Reliability study. SETTING: Assessments were administered at different clinical locations in Germany and Switzerland by the same 2 investigators. PARTICIPANTS: Forty-eight active individuals participated in this study (N=48). MAIN OUTCOME MEASURES: The participants performed MFHs and Forward hops for distance in a predetermined order. The feasibility of the MFH was quantified with proportions of successfully executed attempts and Pearson's χ2 test. Its reliability was estimated using intraclass correlation coefficient (ICC) and standard error of measurement (SEM). Test validity was explored using Pearson's product moment correlation analyses. RESULTS: Fewer failed attempts were recorded among the participants (age: 30 [Standard deviation 11] years; 22 women, 26 (13) months post-surgery) when compared with the Forward hop for distance test (25/288 trials; 9% vs 72/288 trials; 25%). Within-session ICC values were excellent (>0.95) for both types of Forward hop tests, independent of the side examined. The SEM values were comparable between the Modified (injured: 5.6 cm, uninjured: 5.9 cm) and the classic Forward hop (injured: 4.3 cm, uninjured: 7.2 cm). CONCLUSION: The MFH is a feasible, reliable, and valid tool for judging neuromuscular performance after ACLR. If the aim of a hop for distance incorporates enhanced perceived or real landing safety, landing on both feet should be used.


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Humanos , Feminino , Adulto , Lesões do Ligamento Cruzado Anterior/cirurgia , Reprodutibilidade dos Testes , Estudos de Viabilidade , Ligamento Cruzado Anterior/cirurgia
9.
Rofo ; 196(1): 25-35, 2024 Jan.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-37793417

RESUMO

BACKGROUND: Photon-counting detector computed tomography (PCD-CT) is a promising new technology with the potential to fundamentally change workflows in the daily routine and provide new quantitative imaging information to improve clinical decision-making and patient management. METHOD: The contents of this review are based on an unrestricted literature search of PubMed and Google Scholar using the search terms "photon-counting CT", "photon-counting detector", "spectral CT", "computed tomography" as well as on the authors' own experience. RESULTS: The fundamental difference with respect to the currently established energy-integrating CT detectors is that PCD-CT allows for the counting of every single photon at the detector level. Based on the identified literature, PCD-CT phantom measurements and initial clinical studies have demonstrated that the new technology allows for improved spatial resolution, reduced image noise, and new possibilities for advanced quantitative image postprocessing. CONCLUSION: For clinical practice, the potential benefits include fewer beam hardening artifacts, a radiation dose reduction, and the use of new or combinations of contrast agents. In particular, critical patient groups such as oncological, cardiovascular, lung, and head & neck as well as pediatric patient collectives benefit from the clinical advantages. KEY POINTS: · Photon-counting computed tomography (PCD-CT) is being used for the first time in routine clinical practice, enabling a significant dose reduction in critical patient populations such as oncology, cardiology, and pediatrics.. · Compared to conventional CT, PCD-CT enables a reduction in electronic image noise.. · Due to the spectral data sets, PCD-CT enables fully comprehensive post-processing applications.. CITATION FORMAT: · Hagen F, Soschynski M, Weis M et al. Photon-counting computed tomography - clinical application in oncological, cardiovascular, and pediatric radiology. Fortschr Röntgenstr 2024; 196: 25 - 34.


Assuntos
Radiologia , Tomografia Computadorizada por Raios X , Humanos , Criança , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Tórax , Imagens de Fantasmas , Pulmão
10.
Invest Radiol ; 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38038693

RESUMO

OBJECTIVE: Accurate locoregional staging is crucial for effective breast cancer treatment. Photon-counting computed tomography (PC-CT) is an emerging technology with high spatial resolution and the ability to depict uptake of contrast agents in tissues, making it a promising tool for breast cancer imaging. The aim of this study was to establish the feasibility of locoregional staging of breast cancer through contrast-enhanced thoracic PC-CT, assess its diagnostic performance, and compare it with that of digital mammography (DM). MATERIALS AND METHODS: Patients with newly diagnosed breast cancer, DM, and indication of thoracic CT staging were prospectively enrolled in this clinical cohort study over a period of 6 months. Participants underwent contrast-enhanced thoracic PC-CT and breast magnetic resonance imaging in prone position. After blinding to patient data, 2 radiologists independently rated PC-CT and DM regarding the following 6 characteristics: (1) diameter of the largest mass lesion, (2) infiltration of cutis/pectoral muscle/thoracic wall, (3) number of mass lesions, (4) presence/absence of adjacent ductal carcinoma in situ (DCIS), (5) tumor conspicuity, and (6) diagnostic confidence. Reference standard was generated from consensus reading of magnetic resonance imaging combined with all histopathological/clinical data by an independent adjudication committee applying TNM eighth edition. RESULTS: Among 32 enrolled female subjects (mean ± SD age, 59 ± 13.0 years), diagnostic accuracy for T-classification was higher for PC-CT compared with DM (0.94 vs 0.50, P < 0.01). Moreover, the correlation of the number of detected tumor masses with the reference standard was stronger for PC-CT than for DM (0.72 vs 0.50, P < 0.01). We observed that PC-CT significantly (P < 0.04) outperformed DM regarding not only sensitivity (0.83 and 0.25, respectively) but also specificity (0.99 and 0.80, respectively) for adjacent DCIS. The κ values for interreader reliability were higher for PC-CT compared with DM (mean 0.88 vs 0.54, respectively; P = 0.01). CONCLUSIONS: Photon-counting computed tomography outperformed DM in T-classification and provided higher diagnostic accuracy for the detection of adjacent DCIS. Therefore, opportunistic locoregional staging of breast cancer in contrast-enhanced thoracic PC-CT is feasible and could overcome limitations of DM with the potential to improve patient management.

11.
Z Med Phys ; 2023 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-38104007

RESUMO

OBJECTIVES: Despite their life-saving capabilities, cerebrospinal fluid (CSF) shunts exhibit high failure rates, with a large fraction of failures attributed to the regulating valve. Due to a lack of methods for the detailed analysis of valve malfunctions, failure mechanisms are not well understood, and valves often have to be surgically explanted on the mere suspicion of malfunction. The presented pilot study aims to demonstrate radiological methods for comprehensive analysis of CSF shunt valves, considering both the potential for failure analysis in design optimization, and for future clinical in-vivo application to reduce the number of required shunt revision surgeries. The proposed method could also be utilized to develop and support in situ repair methods (e.g. by lysis or ultrasound) of malfunctioning CSF shunt valves. MATERIALS AND METHODS: The primary methods described are contrast-enhanced radiographic time series of CSF shunt valves, taken in a favorable projection geometry at low radiation dose, and the machine-learning-based diagnosis of CSF shunt valve obstructions. Complimentarily, we investigate CT-based methods capable of providing accurate ground truth for the training of such diagnostic tools. Using simulated test and training data, the performance of the machine-learning diagnostics in identifying and localizing obstructions within a shunt valve is evaluated regarding per-pixel sensitivity and specificity, the Dice similarity coefficient, and the false positive rate in the case of obstruction free test samples. RESULTS: Contrast enhanced subtraction radiography allows high-resolution, time-resolved, low-dose analysis of fluid transport in CSF shunt valves. Complementarily, photon-counting micro-CT allows to investigate valve obstruction mechanisms in detail, and to generate valid ground truth for machine learning-based diagnostics. Machine-learning-based detection of valve obstructions in simulated radiographies shows promising results, with a per-pixel sensitivity >70%, per-pixel specificity >90%, a median Dice coefficient >0.8 and <10% false positives at a detection threshold of 0.5. CONCLUSIONS: This ex-vivo study demonstrates obstruction detection in cerebro-spinal fluid shunt valves, combining radiological methods with machine learning under conditions compatible to future in-vivo application. Results indicate that high-resolution contrast-enhanced subtraction radiography, possibly including time-series data, combined with machine-learning image analysis, has the potential to strongly improve the diagnostics of CSF shunt valve failures. The presented method is in principle suitable for in-vivo application, considering both measurement geometry and radiological dose. Further research is needed to validate these results on real-world data and to refine the employed methods. In combination, the presented methods enable comprehensive analysis of valve failure mechanisms, paving the way for improved product development and clinical diagnostics of CSF shunt valves.

12.
Eur Radiol ; 2023 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-37968474

RESUMO

OBJECTIVES: Metal artifacts remain a challenge in computed tomography. We investigated the potential of photon-counting computed tomography (PCD-CT) for metal artifact reduction using an iterative metal artifact reduction (iMAR) algorithm alone and in combination with high keV monoenergetic images (140 keV) in patients with dental hardware. MATERIAL AND METHODS: Consecutive patients with dental implants were prospectively included in this study and received PCD-CT imaging of the craniofacial area. Four series were reconstructed (standard [PCD-CTstd], monoenergetic at 140 keV [PCD-CT140keV], iMAR corrected [PCD-CTiMAR], combination of iMAR and 140 keV monoenergetic [PCD-CTiMAR+140keV]). All reconstructions were assessed qualitatively by four radiologists (independent and blinded reading on a 5-point Likert scale [5 = excellent; no artifact]) regarding overall image quality, artifact severity, and delineation of adjacent and distant anatomy. To assess signal homogeneity and evaluate the magnitude of artifact reduction, we performed quantitative measures of coefficient of variation (CV) and a region of interest (ROI)-based relative change in artifact reduction [PCD-CT/PCD-CTstd]. RESULTS: We enrolled 48 patients (mean age 66.5 ± 11.2 years, 50% (n = 24) males; mean BMI 25.2 ± 4.7 kg/m2; mean CTDIvol 6.2 ± 6 mGy). We found improved overall image quality, reduced artifacts and superior delineation of both adjacent and distant anatomy for the iMAR vs. non-iMAR reconstructions (all p < 0.001). No significant effect of the different artifact reduction approaches on CV was observed (p = 0.42). The ROI-based analysis indicated the most effective artifact reduction for the iMAR reconstructions, which was significantly higher compared to PCD-CT140keV (p < 0.001). CONCLUSION: PCD-CT offers highly effective approaches for metal artifact reduction with the potential to overcome current diagnostic challenges in patients with dental implants. CLINICAL RELEVANCE STATEMENT: Metallic artifacts pose a significant challenge in CT imaging, potentially leading to missed findings. Our study shows that PCD-CT with iMAR post-processing reduces artifacts, improves image quality, and can possibly reveal pathologies previously obscured by artifacts, without additional dose application. KEY POINTS: • Photon-counting detector CT (PCD-CT) offers highly effective approaches for metal artifact reduction in patients with dental fillings/implants. • Iterative metal artifact reduction (iMAR) is superior to high keV monoenergetic reconstructions at 140 keV for artifact reduction and provides higher image quality. • Signal homogeneity of the reconstructed images is not affected by the different artifact reduction techniques.

13.
Sci Rep ; 13(1): 14806, 2023 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-37684412

RESUMO

Accurate small vessel stent visualization using CT remains challenging. Photon-counting CT (PCD-CT) may help to overcome this issue. We systematically investigate PCD-CT impact on small vessel stent assessment compared to energy-integrating-CT (EID). 12 water-contrast agent filled stents (3.0-8 mm) were scanned with patient-equivalent phantom using clinical PCD-CT and EID-CT. Images were reconstructed using dedicated vascular kernels. Subjective image quality was evaluated by 5 radiologists independently (5-point Likert-scale; 5 = excellent). Objective image quality was evaluated by calculating multi-row intensity profiles including edge rise slope (ERS) and coefficient-of-variation (CV). Highest overall reading scores were found for PCD-CT-Bv56 (3.6[3.3-4.3]). In pairwise comparison, differences were significant for PCD-CT-Bv56 vs. EID-CT-Bv40 (p ≤ 0.04), for sharpness and blooming respectively (all p < 0.05). Highest diagnostic confidence was found for PCD-CT-Bv56 (p ≤ 0.2). ANOVA revealed a significant effect of kernel strength on ERS (p < 0.001). CV decreased with stronger PCD-CT kernels, reaching its lowest in PCD-CT-Bv56 and highest in EID-CT reconstruction (p ≤ 0.05). We are the first study to verify, by phantom setup adapted to real patient settings, PCD-CT with a sharp vascular kernel provides the most favorable image quality for small vessel stent imaging. PCD-CT may reduce the number of invasive coronary angiograms, however, more studies needed to apply our results in clinical practice.


Assuntos
Prótese Vascular , Doença da Artéria Coronariana , Tomografia Computadorizada por Raios X , Tomografia Computadorizada por Raios X/métodos , Diagnóstico por Imagem , Imagens de Fantasmas , Humanos , Doença da Artéria Coronariana/terapia
14.
Korean J Radiol ; 24(10): 1006-1016, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37724589

RESUMO

OBJECTIVE: Computed tomography (CT) is an established method for the diagnosis, staging, and treatment of multiple myeloma. Here, we investigated the potential of photon-counting detector computed tomography (PCD-CT) in terms of image quality, diagnostic confidence, and radiation dose compared with energy-integrating detector CT (EID-CT). MATERIALS AND METHODS: In this prospective study, patients with known multiple myeloma underwent clinically indicated whole-body PCD-CT. The image quality of PCD-CT was assessed qualitatively by three independent radiologists for overall image quality, edge sharpness, image noise, lesion conspicuity, and diagnostic confidence using a 5-point Likert scale (5 = excellent), and quantitatively for signal homogeneity using the coefficient of variation (CV) of Hounsfield Units (HU) values and modulation transfer function (MTF) via the full width at half maximum (FWHM) in the frequency space. The results were compared with those of the current clinical standard EID-CT protocols as controls. Additionally, the radiation dose (CTDIvol) was determined. RESULTS: We enrolled 35 patients with multiple myeloma (mean age 69.8 ± 9.1 years; 18 [51%] males). Qualitative image analysis revealed superior scores (median [interquartile range]) for PCD-CT regarding overall image quality (4.0 [4.0-5.0] vs. 4.0 [3.0-4.0]), edge sharpness (4.0 [4.0-5.0] vs. 4.0 [3.0-4.0]), image noise (4.0 [4.0-4.0] vs. 3.0 [3.0-4.0]), lesion conspicuity (4.0 [4.0-5.0] vs. 4.0 [3.0-4.0]), and diagnostic confidence (4.0 [4.0-5.0] vs. 4.0 [3.0-4.0]) compared with EID-CT (P ≤ 0.004). In quantitative image analyses, PCD-CT compared with EID-CT revealed a substantially lower FWHM (2.89 vs. 25.68 cy/pixel) and a significantly more homogeneous signal (mean CV ± standard deviation [SD], 0.99 ± 0.65 vs. 1.66 ± 0.5; P < 0.001) at a significantly lower radiation dose (mean CTDIvol ± SD, 3.33 ± 0.82 vs. 7.19 ± 3.57 mGy; P < 0.001). CONCLUSION: Whole-body PCD-CT provides significantly higher subjective and objective image quality at significantly reduced radiation doses than the current clinical standard EID-CT protocols, along with readily available multi-spectral data, facilitating the potential for further advanced post-processing.

15.
Diagnostics (Basel) ; 13(12)2023 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-37370957

RESUMO

BACKGROUND: This study investigates whether the scan length adjustment of prospectively ECG-triggered coronary CT angiography (CCTA) using calcium-scoring CT (CAS-CT) images can reduce overall radiation doses. METHODS: A retrospective analysis was conducted on 182 patients who underwent CAS-CT and prospectively ECG-triggered CCTA using a second-generation Dual-Source CT scanner. CCTA planning was based on CAS-CT images, for which simulated scout view planning was performed for comparison. Effective doses were compared between two scenarios: Scenario 1-CAS-CT-derived CCTA + CAS-CT and Scenario 2-scout-view-derived CCTA without CAS-CT. Dose differences were further analyzed with respect to scan mode and body mass index. RESULTS: Planning CCTA using CAS-CT led to a shorter scan length than planning via scout view (114.3 ± 9.7 mm vs. 133.7 ± 13.2 mm, p < 0.001). The whole-examination effective dose was slightly lower for Scenario 1 (3.2 [1.8-5.3] mSv vs. 3.4 [1.5-5.9] mSv; p < 0.001, n = 182). Notably, Scenario 1 resulted in a significantly lower radiation dose for sequential scans and obese patients. Only high-pitch spiral CCTA showed dose reduction in Scenario 2. CONCLUSIONS: Using CAS-CT for planning prospectively ECG-triggered CCTA reduced the overall radiation dose administered compared to scout view planning without CAS-CT, except for high-pitch spiral CCTA, where a slightly opposite effect was observed.

16.
Radiology ; 307(5): e223305, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37338354

RESUMO

Background Recently introduced photon-counting CT may improve noninvasive assessment of patients with high risk for coronary artery disease (CAD). Purpose To determine the diagnostic accuracy of ultrahigh-resolution (UHR) coronary CT angiography (CCTA) in the detection of CAD compared with the reference standard of invasive coronary angiography (ICA). Materials and Methods In this prospective study, participants with severe aortic valve stenosis and clinically indicated CT for transcatheter aortic valve replacement planning were consecutively enrolled from August 2022 to February 2023. All participants were examined with a dual-source photon-counting CT scanner using a retrospective electrocardiography-gated contrast-enhanced UHR scanning protocol (tube voltage, 120 or 140 kV; collimation, 120 × 0.2 mm; 100 mL of iopromid; no spectral information). Subjects underwent ICA as part of their clinical routine. A consensus assessment of image quality (five-point Likert scale: 1 = excellent [absence of artifacts], 5 = nondiagnostic [severe artifacts]) and a blinded independent reading for the presence of CAD (stenosis ≥50%) were performed. UHR CCTA was compared with ICA using area under the receiver operating characteristic curve (AUC). Results Among 68 participants (mean age, 81 years ± 7 [SD]; 32 male, 36 female), the prevalence of CAD and prior stent placement was 35% and 22%, respectively. The overall image quality was excellent (median score, 1.5 [IQR, 1.3-2.0]). The AUC of UHR CCTA in the detection of CAD was 0.93 per participant (95% CI: 0.86, 0.99), 0.94 per vessel (95% CI: 0.91, 0.98), and 0.92 per segment (95% CI: 0.87, 0.97). Sensitivity, specificity, and accuracy, respectively, were 96%, 84%, and 88% per participant (n = 68); 89%, 91%, and 91% per vessel (n = 204); and 77%, 95%, and 95% per segment (n = 965). Conclusion UHR photon-counting CCTA provided high diagnostic accuracy in the detection of CAD in a high-risk population, including subjects with severe coronary calcification or prior stent placement. Published under a CC BY 4.0 license. Supplemental material is available for this article. See also the editorial by Williams and Newby in this issue.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Humanos , Masculino , Feminino , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/diagnóstico por imagem , Estudos Prospectivos , Estudos Retrospectivos , Angiografia Coronária/métodos , Tomografia Computadorizada por Raios X/métodos
17.
Med Sci (Basel) ; 11(2)2023 05 29.
Artigo em Inglês | MEDLINE | ID: mdl-37367739

RESUMO

BACKGROUND/OBJECTIVES: Comprehensive Geriatric Care (CGC) is a specific multimodal treatment for older patients. In the current study, we aimed to investigate walking performance after CGC in medically ill patients versus those with fractures. METHODS: The timed up and go test (TuG), a 5-grade scale assessment (1 = no walking impairment to 5 = no walking ability at all) for evaluating individual walking ability was performed in all patients who underwent CGC prior to and after treatment. Factors associated with improvement in walking ability were analyzed in the subgroup of patients with fractures. RESULTS: Out of 1263 hospitalized patients, 1099 underwent CGC (median age: 83.1 years (IQR 79.0-87.8 years); 64.1% were female). Patients with fractures (n = 300) were older than those without (n = 799), (median 85.6 versus 82.4 years, p = 0.001). Improvement in TuG after CGC was found in 54.2% of the fracture patients compared to just 45.9% of those without fractures. In fracture group patients, TuG improved from median 5 on admission to median 3 on discharge (p = 0.001). In fracture patients, improvement in walking ability was associated with higher Barthel index values on admission (median 45 (IQR: 35-55) versus 35 (IQR: 20-50): p = 0.001) and Tinetti assessment scores (median 9 (IQR: 4-14.25) versus 5 (IQR: 0-13); p = 0.001) and was negatively associated with the diagnosis of dementia (21.4% versus 31.5%; p = 0.058). CONCLUSION: CGC improved walking ability in more than half of all patients examined. Older patients in particular might benefit from undergoing the procedure after an acute fracture. A better initial functional status favors a positive result following the treatment.


Assuntos
Fraturas do Quadril , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Masculino , Equilíbrio Postural , Estudos de Tempo e Movimento , Atividades Cotidianas , Assistência Integral à Saúde
18.
Cell Rep Med ; 4(5): 101036, 2023 05 16.
Artigo em Inglês | MEDLINE | ID: mdl-37196635

RESUMO

Genetic and in vivo evidence suggests that aberrant recognition of RNA-containing autoantigens by Toll-like receptors (TLRs) 7 and 8 drives autoimmune diseases. Here we report on the preclinical characterization of MHV370, a selective oral TLR7/8 inhibitor. In vitro, MHV370 inhibits TLR7/8-dependent production of cytokines in human and mouse cells, notably interferon-α, a clinically validated driver of autoimmune diseases. Moreover, MHV370 abrogates B cell, plasmacytoid dendritic cell, monocyte, and neutrophil responses downstream of TLR7/8. In vivo, prophylactic or therapeutic administration of MHV370 blocks secretion of TLR7 responses, including cytokine secretion, B cell activation, and gene expression of, e.g., interferon-stimulated genes. In the NZB/W F1 mouse model of lupus, MHV370 halts disease. Unlike hydroxychloroquine, MHV370 potently blocks interferon responses triggered by specific immune complexes from systemic lupus erythematosus patient sera, suggesting differentiation from clinical standard of care. These data support advancement of MHV370 to an ongoing phase 2 clinical trial.


Assuntos
Doenças Autoimunes , Lúpus Eritematoso Sistêmico , Humanos , Camundongos , Animais , Receptor 7 Toll-Like/metabolismo , Receptor 7 Toll-Like/uso terapêutico , Lúpus Eritematoso Sistêmico/tratamento farmacológico , Lúpus Eritematoso Sistêmico/metabolismo , Hidroxicloroquina/farmacologia , Hidroxicloroquina/uso terapêutico , Interferons
19.
BMC Sports Sci Med Rehabil ; 15(1): 49, 2023 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-37005699

RESUMO

BACKGROUND: Numerous individual, temporal, injury- and surgery-specific factors impact the functional capacity during rehabilitation, return to sports (RTS), and re-injury prevention after an anterior cruciate ligament (ACL) reconstruction. PURPOSE: This multicentre cohort study evaluated the isolated and interactive contributions of time between injury and surgery, time since reconstruction, age, gender, pain, graft type, and concomitant injuries as to inertial sensor-assessed motor function after ACL reconstructions in multiple linear mixed model regressions. METHODS: Anonymized data were retrieved from a nationwide German registry. In this cohort study, patients with an acute unilateral ACL rupture, with or without concomitant ipsilateral knee injuries, and having passed an arthroscopically assisted anatomic reconstruction were included. Potential predictors were age [years], gender/sex, time since reconstruction [days], time between injury and reconstruction [days], concomitant intra-articular injuries (isolated ACL tear, meniscal tear, lateral ligament, unhappy triad), graft type (hamstrings, patellar, or quadriceps tendon autograft), and pain during each measurement (visual analogue scale 0-10 cm). Repeated inertial motion unit-assessments of a comprehensive battery of classic functional RTS test were performed in the course of the rehabilitation and return to sports: Joint position sense/kinesthesia (Angle reproduction error [degrees]), Dynamic Balance Composite score [cm] of the Y-Balance test), drop jumps (Knee displacement [cm]), Vertical hop (Hopping height [mm]), Speedy jumps (Duration [seconds]), Side hops (Number of hops [n]), single leg hop for distance (hopping distance [cm]). Repeated measures multiple linear mixed models investigated the impact and nesting interaction of the potential predictors on the functional outcomes. RESULTS: Data from 1441 persons (mean age 29.4, SD 11.8 years; 592 female, 849 male) were included. Most had an isolated ACL rupture: n = 938 (65.1%). Minor shares showed lateral ligament involvement: n = 70 (4.9%), meniscal tear: n = 414 (28.7%), or even unhappy triad: n = 15 (1%). Several predictors such as time between injury and reconstruction, time since reconstruction (estimates for ndays ranged from + .05 (i.e., an increase of the hopping distance of 0.05 cm per day since reconstruction occurs) for single leg hop for distance to + 0.17 for vertical hopping height; p < 0.001), age, gender, pain, graft type (patellar tendon graft: estimates between + 0.21 for Y-balance and + 0.48 for vertical hop performance; p < 0.001), and concomitant injuries contribute to the individual courses of functional abilities of the reconstructed side after ACL reconstruction. The unimpaired side was mostly influenced by sex, age, the time between injury and reconstruction (estimates between - 0.0033 (side hops) and + 0.10 (vertical hopping height), p < 0.001)), and time since reconstruction. CONCLUSIONS: Time since reconstruction, time between injury and reconstruction, age, gender, pain, graft type, and concomitant injuries are not independent but nested interrelating predictors of functional outcomes after anterior cruciate ligament reconstruction. It might not be enough to assess them isolated; the knowledge on their interactive contribution to motor function is helpful for the management of the reconstruction (earlier reconstructions should be preferred) deficit-oriented function-based rehabilitation (time- and function based rehabilitation instead of solely a time- or function based approach) and individualized return to sports strategies.

20.
Knee Surg Sports Traumatol Arthrosc ; 31(8): 3441-3453, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37120794

RESUMO

PURPOSE: To determine potential quadriceps versus hamstring tendon autograft differences in neuromuscular function and return to sport (RTS)-success in participants after an anterior cruciate ligament (ACL) reconstruction. METHODS: Case-control study on 25 participants operated on with an arthroscopically assisted, anatomic ipsilateral quadriceps femoris tendon graft and two control groups of 25 participants each, operated on with a semitendinosus tendon or semitendinosus-gracilis (hamstring) tendon graft ACL reconstruction. Participants of the two control groups were propensity score matched to the case group based on sex, age, Tegner activity scale and either the total volume of rehabilitation since reconstruction (n = 25) or the time since reconstruction (n = 25). At the end of the rehabilitation (averagely 8 months post-reconstruction), self-reported knee function (KOOS sum scores), fear of loading the reconstructed knee during a sporting activity (RSI-ACL questionnaire), and fear of movement (Tampa scale of kinesiophobia) were followed by hop and jump tests. Front hops for distance (jumping distance as the outcome) were followed by Drop jumps (normalised knee joint separation distance), and concluded by qualitative ratings of the Balanced front and side hops. Between-group comparisons were undertaken using 95% confidence intervals comparisons, effect sizes were calculated. RESULTS: The quadriceps case group (always compared with the rehabilitation-matched hamstring graft controls first and versus time-matched hamstring graft controls second) had non-significant and only marginal higher self-reported issues during sporting activities: Cohen's d = 0.42, d = 0.44, lower confidence for RTS (d = - 0.30, d = - 0.16), and less kinesiophobia (d = - 0.25, d = 0.32). Small and once more non-significant effect sizes point towards lower values in the quadriceps graft groups in the Front hop for distance limb symmetry values in comparison to the two hamstring control groups (d = - 0.24, d = - 0.35). The normalised knee joint separation distance were non-significantly and small effect sized higher in the quadriceps than in the hamstring groups (d = 0.31, d = 0.28). CONCLUSION: Only non-significant and marginal between-graft differences in the functional outcomes at the end of the rehabilitation occurred. The selection of either a hamstring or a quadriceps graft type cannot be recommended based on the results. The decision must be undertaken individually. LEVEL OF EVIDENCE: III.


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Músculos Isquiossurais , Tendões dos Músculos Isquiotibiais , Humanos , Músculo Quadríceps/cirurgia , Músculos Isquiossurais/cirurgia , Estudos de Casos e Controles , Pontuação de Propensão , Reconstrução do Ligamento Cruzado Anterior/métodos , Tendões dos Músculos Isquiotibiais/transplante , Autoenxertos/transplante
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...