Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 108
Filtrar
1.
Rev Lat Am Enfermagem ; 32: e4272, 2024.
Artigo em Inglês, Português, Espanhol | MEDLINE | ID: mdl-39230130

RESUMO

OBJECTIVE: to analyze the reliability of the items that compose the instrument for classifying newborns according to the degree of dependence on nursing care in a neonatal intensive care unit. METHOD: methodological study that analyzed the agreement and reliability of the instrument in a neonatal intensive care unit. Six care nurses and a research nurse assessed 35 newborns and completed the instrument, which was made up of 15 areas of care. The weighted Kappa coefficient and the Intraclass Correlation Coefficient were used for analysis. RESULTS: the areas of: weight (92%), oxygenation (93%) and catheter control (95%) had almost perfect agreement and the area of reaction to stimuli (50%) had poor agreement. The areas of elimination and vital signs showed low reliability, due to the low variability of responses. The Intraclass Correlation Coefficient was 0.94. CONCLUSION: there are variations in the evaluations of some areas of care due to the imprecise description of items to which scores are assigned, however the instrument is reliable for categorizing the type of care (minimal, intermediate and intensive). Its use can contribute to measuring the quality and safety of newborn care.


Assuntos
Terapia Intensiva Neonatal , Humanos , Recém-Nascido , Reprodutibilidade dos Testes , Feminino , Masculino , Terapia Intensiva Neonatal/normas , Terapia Intensiva Neonatal/classificação , Unidades de Terapia Intensiva Neonatal/normas , Enfermagem Neonatal/normas
2.
Braz Oral Res ; 38: e066, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39109763

RESUMO

This study assessed the physicochemical and antibiofilm properties of white mineral trioxide aggregate (MTA) associated with 1 or 2% of farnesol. Setting time was evaluated based on ISO 6876/2012. Radiopacity was evaluated by radiographic analysis. pH was assessed after time intervals of 1, 3, 7, 14, 21, and 28 days. Solubility (% mass loss) and volumetric change (by micro-CT) of the cements were evaluated after immersion in distilled water. The presence of voids inside the materials was assessed by using micro-CT. Antibiofilm activity against Enterococcus faecalis was evaluated by crystal violet assay and the modified direct contact test performed with biofilm previously formed on bovine root dentin for 14 days. Data were submitted to ANOVA/Tukey tests with 5% significance level. The incorporation of farnesol into MTA increased its setting time, but decreased its solubility at 30 days and its volumetric loss in all periods (p < 0.05). Radiopacity and solubility after 7 days were similar among the materials (p > 0.05). The association of farnesol showed the highest pH value after 1 and 3 days (p < 0.05). The association of farnesol with MTA promoted a decrease in the presence of voids, and increased the antimicrobial activity on biofilm biomass of E. faecalis (p < 0.05). In conclusion, the addition of farnesol can be suggested to improve the antimicrobial properties and the consistency of MTA.


Assuntos
Compostos de Alumínio , Biofilmes , Compostos de Cálcio , Combinação de Medicamentos , Enterococcus faecalis , Farneseno Álcool , Teste de Materiais , Óxidos , Materiais Restauradores do Canal Radicular , Silicatos , Solubilidade , Silicatos/farmacologia , Silicatos/química , Óxidos/farmacologia , Óxidos/química , Biofilmes/efeitos dos fármacos , Compostos de Cálcio/farmacologia , Compostos de Cálcio/química , Enterococcus faecalis/efeitos dos fármacos , Compostos de Alumínio/farmacologia , Compostos de Alumínio/química , Farneseno Álcool/farmacologia , Farneseno Álcool/química , Concentração de Íons de Hidrogênio , Fatores de Tempo , Bovinos , Materiais Restauradores do Canal Radicular/farmacologia , Materiais Restauradores do Canal Radicular/química , Animais , Análise de Variância , Reprodutibilidade dos Testes , Dentina/efeitos dos fármacos , Valores de Referência , Propriedades de Superfície/efeitos dos fármacos
3.
Braz Oral Res ; 38: e022, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39016364

RESUMO

Both root canal sealer-based and supplementary protocols may influence removal of filling material during endodontic retreatment. Mesial root canals of extracted mandibular molars were prepared using HyFlex EDM 25/.08, and filled with a calcium silicate sealer (Bio-C Sealer), or an epoxy resin (AH Plus), using the single cone technique (n = 12). Retreatment was performed using ProDesign Logic (PDL) RT and PDL 35/.05. The specimens were randomly divided into two experimental groups (n = 12), and the sealers were distributed similarly. A supplementary protocol was performed with PDL 50/.01 or XP-endo Finisher. Root canal transportation and volume, in addition to the remaining filling material percentage were evaluated using high-resolution (5 µm voxel size) micro-CT. Statistical analysis was performed using t-tests (α = 0.05). Root canals filled with AH Plus presented high residual filling material (p < 0.05). Both protocols decreased residual volume of filling material in the apical third (p < 0.05). PDL 50/.01 increased the apical root canal volume (p < 0.05). No difference was observed between the systems regarding canal transportation (p > 0.05). In conclusion, AH Plus is more difficult to remove from the apical third than Bio-C Sealer. PDL 50/.01 and XP-endo Finisher enabled greater removal of filling materials in the apical third, in the retreatment of curved root canals, without promoting apical transport.


Assuntos
Resinas Epóxi , Teste de Materiais , Retratamento , Materiais Restauradores do Canal Radicular , Microtomografia por Raio-X , Materiais Restauradores do Canal Radicular/química , Materiais Restauradores do Canal Radicular/uso terapêutico , Humanos , Retratamento/métodos , Resinas Epóxi/química , Resinas Epóxi/uso terapêutico , Preparo de Canal Radicular/métodos , Preparo de Canal Radicular/instrumentação , Cavidade Pulpar/diagnóstico por imagem , Cavidade Pulpar/efeitos dos fármacos , Compostos de Cálcio/uso terapêutico , Silicatos/química , Reprodutibilidade dos Testes , Obturação do Canal Radicular/métodos , Dente Molar , Valores de Referência
4.
Sci Rep ; 14(1): 16768, 2024 07 22.
Artigo em Inglês | MEDLINE | ID: mdl-39039132

RESUMO

This study evaluated the biocompatibility, bioactivity, porosity, and sealer/dentin interface of Sealer Plus BC (SP), Bio-C Sealer (BIOC), TotalFill BC Sealer (TF), and AH Plus (AHP). Dentin tubes filled with the sealers and empty tubes (control group) were implanted in the subcutaneous tissue of rats for different periods (n = 6 per group/period). Number of inflammatory cells (ICs), capsule thickness, von Kossa reaction, interleukin-6 (IL-6) and osteocalcin (OCN) were evaluated. Porosity and voids in the interface dentin/sealers were assessed by micro-computed tomography. The data were submitted to ANOVA/Tukey's tests (α = 0.05). Greater capsule thickness, ICs and IL-6 immunolabeling cells were observed in AHP. No significant difference in thickness of capsule, ICs, and IL-6- immunolabeling cells was detected between SP and TF, in all periods, and after 30 and 60 days between all groups. At 60 days all groups had reduction in capsule thickness, ICs and IL-6 immunolabeling cells. Von Kossa-positive and birefringent structures were observed in the capsules around the sealers. BIOC, SP, and TF exhibited OCN-immunolabeling cells. All sealers had porosity values below 5%, besides low and similar interface voids. BIOC, SP and TF are biocompatible, bioactive, and have low porosity and voids. The dentin-tube model used is an alternative for evaluating bioceramic materials.


Assuntos
Materiais Biocompatíveis , Dentina , Teste de Materiais , Animais , Porosidade , Dentina/química , Dentina/metabolismo , Materiais Biocompatíveis/química , Materiais Biocompatíveis/farmacologia , Ratos , Cerâmica/química , Interleucina-6/metabolismo , Microtomografia por Raio-X , Masculino , Ratos Wistar , Selantes de Fossas e Fissuras/química
5.
J Endod ; 50(5): 612-618, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38278319

RESUMO

INTRODUCTION: The aim of this study was to evaluate the effectiveness of the XP-endo Finisher R (XPFR; FKG Dentaire, La Chaux-de-Fonds, Switzerland) or the Flatsonic ultrasonic tip (Helse Ultrasonic, Santa Rosa de Viterbo, SP, Brazil) in removing remaining filling material after the retreatment of flattened root canals using micro-computed tomographic imaging. METHODS: Twenty-four flattened distal root canals of mandibular molars with a buccolingual diameter 4 or more times larger than the mesiodistal diameter were prepared with Reciproc Blue (RB) R40 (VDW GmbH, Munich, Germany) and filled using the Tagger hybrid technique. All canals were retreated with RB R40, and apical enlargement was performed with RB R50 (VDW GmbH). The specimens were randomly distributed into 2 groups: XPFR or Flatsonic (n = 12). The percentage of remaining filling material after retreatment and centralization ability was evaluated. Data were submitted to Mann-Whitney, Wilcoxon, and unpaired t tests (α = 5%). RESULTS: Greater capacity to remove remaining filling material in the entire canal and the cervical and middle thirds was observed for the Flatsonic compared with the XPFR (P < .05). However, both supplementary cleaning techniques showed a similar percentage of residual filling material in the apical third (P > .05). No difference was observed in the centralization ability between the techniques (P > .05). CONCLUSIONS: The Flatsonic promotes greater removal of remaining filling material than the XPFR in the retreatment of flattened root canals. However, both supplementary cleaning approaches were similar in the apical third. The XPFR and Flatsonic were able to maintain root canal centralization.


Assuntos
Cavidade Pulpar , Dente Molar , Materiais Restauradores do Canal Radicular , Preparo de Canal Radicular , Microtomografia por Raio-X , Microtomografia por Raio-X/métodos , Humanos , Cavidade Pulpar/diagnóstico por imagem , Cavidade Pulpar/anatomia & histologia , Materiais Restauradores do Canal Radicular/uso terapêutico , Preparo de Canal Radicular/instrumentação , Preparo de Canal Radicular/métodos , Dente Molar/diagnóstico por imagem , Retratamento , Obturação do Canal Radicular/métodos , Terapia por Ultrassom/métodos
6.
Aust Endod J ; 50(1): 52-59, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37902156

RESUMO

The aim of this study was to evaluate the effect of radiopacifier calcium tungstate and manipulation with distilled water (DW) or liquid with additives (LA) on calcium silicate clinker Angelus (CL) properties, compared with MTA (Angelus, Brazil) and MTA Repair HP (MTAHP, Angelus, Brazil). The physicochemical properties, cellular viability and bioactivity were evaluated. ANOVA/Tukey and Bonferroni tests were performed (α = 0.05). There was no difference in material setting time (p > 0.05). MTA and MTAHP were similar (p > 0.05) and had greater radiopacity than CL + DW and CL + LA (p < 0.05). All experimental materials showed mass increase, alkalinisation capacity, besides biocompatibility and bioactivity at 3 and 7 days. The different liquids had no influence in the biological properties and bioactivity of the calcium silicate clinker Angelus. Calcium tungstate provided radiopacity, without changing the setting time, maintaining the mass increase and alkalinisation ability of the calcium silicate materials.


Assuntos
Óxidos , Materiais Restauradores do Canal Radicular , Compostos de Tungstênio , Óxidos/farmacologia , Teste de Materiais , Compostos de Cálcio/farmacologia , Compostos de Cálcio/química , Silicatos/farmacologia , Silicatos/química , Combinação de Medicamentos , Compostos de Alumínio/farmacologia , Materiais Restauradores do Canal Radicular/farmacologia , Materiais Restauradores do Canal Radicular/química
7.
Artigo em Inglês | MEDLINE | ID: mdl-38096641

RESUMO

Chemoreception through odorant receptors (ORs), ionotropic receptors (IRs) and gustatory receptors (GRs) represents the functions of key proteins in the chemical ecology of insects. Recent studies have identified chemoreceptors in coleopterans, facilitating the evolutionary analysis of not only ORs but also IRs and GRs. Thus, Cerambycidae, Tenebrionidae and Curculionidae have received increased attention. However, knowledge of the chemoreceptors from Scarabaeidae is still limited, particularly for those that are sympatric. Considering the roles of chemoreceptors, this analysis could shed light on evolutionary processes in the context of sympatry. Therefore, the aim of this study was to identify and compare the repertoires of ORs, GRs and IRs between two sympatric scarab beetles, Hylamorpha elegans and Brachysternus prasinus. Here, construction of the antennal transcriptomes of both scarab beetle species and analyses of their phylogeny, molecular evolution and relative expression were performed. Thus, 119 new candidate chemoreceptors were identified for the first time, including 17 transcripts for B. prasinus (1 GR, 3 IRs and 13 ORs) and 102 for H. elegans (22 GRs, 14 IRs and 66 ORs). Orthologs between the two scarab beetle species were found, revealing specific expansions as well as absence in some clades. Purifying selection appears to have occurred on H. elegans and B. prasinus ORs. Further efforts will be focused on target identification to characterize kairomone and/or pheromone receptors.


Assuntos
Besouros , Receptores Odorantes , Gorgulhos , Animais , Transcriptoma , Simpatria , Perfilação da Expressão Gênica , Besouros/genética , Besouros/metabolismo , Gorgulhos/genética , Filogenia , Receptores Odorantes/genética , Receptores Odorantes/metabolismo , Proteínas de Insetos/genética , Proteínas de Insetos/metabolismo , Antenas de Artrópodes/metabolismo
8.
Rev. latinoam. enferm. (Online) ; 32: e4272, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BDENF - Enfermagem | ID: biblio-1569965

RESUMO

Abstract Objective: to analyze the reliability of the items that compose the instrument for classifying newborns according to the degree of dependence on nursing care in a neonatal intensive care unit. Method: methodological study that analyzed the agreement and reliability of the instrument in a neonatal intensive care unit. Six care nurses and a research nurse assessed 35 newborns and completed the instrument, which was made up of 15 areas of care. The weighted Kappa coefficient and the Intraclass Correlation Coefficient were used for analysis. Results: the areas of: weight (92%), oxygenation (93%) and catheter control (95%) had almost perfect agreement and the area of reaction to stimuli (50%) had poor agreement. The areas of elimination and vital signs showed low reliability, due to the low variability of responses. The Intraclass Correlation Coefficient was 0.94. Conclusion: there are variations in the evaluations of some areas of care due to the imprecise description of items to which scores are assigned, however the instrument is reliable for categorizing the type of care (minimal, intermediate and intensive). Its use can contribute to measuring the quality and safety of newborn care.


Resumo Objetivo: analisar a confiabilidade dos itens que compõem o instrumento para classificação de recém-nascido de acordo com o grau de dependência dos cuidados de enfermagem em uma unidade de terapia intensiva neonatal. Método: estudo metodológico que analisou a concordância e a confiança do instrumento em uma unidade de terapia intensiva neonatal. Seis enfermeiros assistenciais e uma enfermeira pesquisadora avaliaram 35 recém-nascidos e preencheram o instrumento, composto por 15 áreas de cuidado. O coeficiente Kappa ponderado e o Coeficiente de Correlação Intraclasse foram utilizados para análise. Resultados: as áreas peso (92%), oxigenação (93%) e controle de cateteres (95%) obtiveram concordância quase perfeita, e a área reação a estímulos (50%) obteve concordância fraca. As áreas eliminações e sinais vitais apresentaram baixa confiabilidade, devido à pouca variabilidade de respostas. O Coeficiente de Correlação Intraclasse foi de 0,94. Conclusão: há variações nas avaliações de algumas áreas de cuidado devido à descrição imprecisa de itens aos quais são atribuídos escores, entretanto, o instrumento é confiável para categorização do tipo de cuidado (mínimo, intermediário e intensivo). Sua utilização pode contribuir para o dimensionamento de qualidade e para a segurança da assistência ao recém-nascido.


Resumen Objetivo: analizar la confiabilidad de los ítems que componen el instrumento para clasificación de recién nacido de acuerdo con el grado de dependencia de los cuidados de enfermería en una unidad de terapia de cuidados intensivos neonatal. Método: estudio metodológico que analizó la concordancia y la confianza del instrumento en una unidad de terapia de cuidados intensivos neonatal. Seis enfermeros asistenciales y una enfermera investigadora evaluaron 35 recién nacidos y completaron el instrumento, compuesto por 15 áreas de cuidado. El coeficiente Kappa ponderado y el Coeficiente de Correlación Intraclase fueron utilizados para el análisis. Resultados: las áreas peso (92%), oxigenación (93%) y control de catéteres (95%) obtuvieron una concordancia casi perfecta y el área reacción a estímulos (50%) obtuvo una concordancia débil. Las áreas eliminaciones y signos vitales presentaron baja confiabilidad, debido a la poca variabilidad de respuestas. El Coeficiente de Correlación Intraclase fue de 0,94. Conclusión: hay variaciones en las evaluaciones de algunas áreas de cuidado debido a la descripción imprecisa de ítems a los cuales se les atribuyen puntuaciones, sin embargo, el instrumento es confiable para la categorización del tipo de cuidado (mínimo, intermedio e intensivo). Su utilización puede contribuir a la planificación de calidad y a la seguridad de la atención al recién nacido.

9.
Braz. oral res. (Online) ; 38: e066, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1568980

RESUMO

Abstract This study assessed the physicochemical and antibiofilm properties of white mineral trioxide aggregate (MTA) associated with 1 or 2% of farnesol. Setting time was evaluated based on ISO 6876/2012. Radiopacity was evaluated by radiographic analysis. pH was assessed after time intervals of 1, 3, 7, 14, 21, and 28 days. Solubility (% mass loss) and volumetric change (by micro-CT) of the cements were evaluated after immersion in distilled water. The presence of voids inside the materials was assessed by using micro-CT. Antibiofilm activity against Enterococcus faecalis was evaluated by crystal violet assay and the modified direct contact test performed with biofilm previously formed on bovine root dentin for 14 days. Data were submitted to ANOVA/Tukey tests with 5% significance level. The incorporation of farnesol into MTA increased its setting time, but decreased its solubility at 30 days and its volumetric loss in all periods (p < 0.05). Radiopacity and solubility after 7 days were similar among the materials (p > 0.05). The association of farnesol showed the highest pH value after 1 and 3 days (p < 0.05). The association of farnesol with MTA promoted a decrease in the presence of voids, and increased the antimicrobial activity on biofilm biomass of E. faecalis (p < 0.05). In conclusion, the addition of farnesol can be suggested to improve the antimicrobial properties and the consistency of MTA.

10.
Braz. oral res. (Online) ; 38: e022, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1564207

RESUMO

Abstract Both root canal sealer-based and supplementary protocols may influence removal of filling material during endodontic retreatment. Mesial root canals of extracted mandibular molars were prepared using HyFlex EDM 25/.08, and filled with a calcium silicate sealer (Bio-C Sealer), or an epoxy resin (AH Plus), using the single cone technique (n = 12). Retreatment was performed using ProDesign Logic (PDL) RT and PDL 35/.05. The specimens were randomly divided into two experimental groups (n = 12), and the sealers were distributed similarly. A supplementary protocol was performed with PDL 50/.01 or XP-endo Finisher. Root canal transportation and volume, in addition to the remaining filling material percentage were evaluated using high-resolution (5 µm voxel size) micro-CT. Statistical analysis was performed using t-tests (α = 0.05). Root canals filled with AH Plus presented high residual filling material (p < 0.05). Both protocols decreased residual volume of filling material in the apical third (p < 0.05). PDL 50/.01 increased the apical root canal volume (p < 0.05). No difference was observed between the systems regarding canal transportation (p > 0.05). In conclusion, AH Plus is more difficult to remove from the apical third than Bio-C Sealer. PDL 50/.01 and XP-endo Finisher enabled greater removal of filling materials in the apical third, in the retreatment of curved root canals, without promoting apical transport.

11.
Front Neurosci ; 17: 1221777, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37609451

RESUMO

Background: Interactions between the somatosensory and motor cortices are of fundamental importance for motor control. Although physically distant, face and hand representations are side by side in the sensorimotor cortex and interact functionally. Traumatic brachial plexus injury (TBPI) interferes with upper limb sensorimotor function, causes bilateral cortical reorganization, and is associated with chronic pain. Thus, TBPI may affect sensorimotor interactions between face and hand representations. Objective: The aim of this study was to investigate changes in hand-hand and face-hand sensorimotor integration in TBPI patients using an afferent inhibition (AI) paradigm. Method: The experimental design consisted of electrical stimulation (ES) applied to the hand or face followed by transcranial magnetic stimulation (TMS) to the primary motor cortex to activate a hand muscle representation. In the AI paradigm, the motor evoked potential (MEP) in a target muscle is significantly reduced when preceded by an ES at short-latency (SAI) or long-latency (LAI) interstimulus intervals. We tested 18 healthy adults (control group, CG), evaluated on the dominant upper limb, and nine TBPI patients, evaluated on the injured or the uninjured limb. A detailed clinical evaluation complemented the physiological investigation. Results: Although hand-hand SAI was present in both the CG and the TBPI groups, hand-hand LAI was present in the CG only. Moreover, less AI was observed in TBPI patients than the CG both for face-hand SAI and LAI. Conclusion: Our results indicate that sensorimotor integration involving both hand and face sensorimotor representations is affected by TBPI.

12.
Clin Oral Investig ; 27(7): 3839-3853, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37014506

RESUMO

OBJECTIVES: This study is to evaluate biocompatibility, bioactive potential, porosity, and dentin/material interface of Bio-C Repair (BIOC-R), MTA Repair HP (MTAHP), and Intermediate Restorative Material (IRM). MATERIALS AND METHODS: Dentin tubes were implanted into subcutaneous of rats for 7, 15, 30, and 60 days. Thickness of capsules, number of inflammatory cells (ICs), interleukin-6 (IL-6), osteocalcin (OCN), and von Kossa were evaluated. Porosity and material/dentin interface voids were also analyzed. Data were submitted to ANOVA and Tukey's tests (p < 0.05). RESULTS: IRM capsules were thicker and contained greater ICs and IL-6-immunopositive cells at 7 and 15 days. BIOC-R capsules exhibited higher thickness and ICs at 7 days and greater IL-6 at 7 and 15 days than MTAHP (p < 0.05). At 30 and 60 days, no significant difference was observed among the groups. OCN-immunopositive cells, von Kossa-positive, and birefringent structures were observed in BIOC-R and MTAHP. MTAHP exhibited higher porosity and interface voids (p < 0.05). CONCLUSIONS: BIOC-R, MTAHP, and IRM are biocompatible. Bioceramics materials demonstrate bioactive potential. MTAHP presented the highest porosity and presence of voids. CLINICAL RELEVANCE: BIOC-R and MTAHP have adequate biological properties. BIOC-R demonstrated lower porosity and presence of voids, which may represent better sealing for its clinical applications.


Assuntos
Materiais Restauradores do Canal Radicular , Ratos , Animais , Materiais Restauradores do Canal Radicular/química , Porosidade , Cápsulas , Interleucina-6 , Teste de Materiais , Compostos de Cálcio/farmacologia , Compostos de Cálcio/química , Silicatos/farmacologia , Silicatos/química , Dentina , Óxidos/química , Combinação de Medicamentos , Compostos de Alumínio/farmacologia , Compostos de Alumínio/química
13.
Braz Dent J ; 34(1): 29-38, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36888842

RESUMO

The aim of this study was to evaluate the physicochemical properties, cytotoxicity and bioactivity of a ready-to-use bioceramic material, Bio-C Repair (Angelus), in comparison with White MTA (Angelus) and Biodentine (Septodont). The physicochemical properties of setting time, radiopacity, pH, solubility, dimensional and volumetric changes were evaluated. Biocompatibility and bioactivity were assessed in Saos-2 osteoblast cell cultures by the MTT assay 3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide), Neutral Red (NR), Alizarin Red (ARS), and cell migration tests. Statistical analysis was performed by ANOVA, Tukey or Bonferroni tests (α = 0.05). Bio-C Repair had the longest setting time (p < 0.05), but radiopacity and solubility were accordance with the ISO 6876/2012 standards, besides linear expansion. Bio-C Repair and MTA had similar volumetric change (p > 0.05); lower than Biodentine (p < 0.05). All the materials evaluated had an alkaline pH. Bio-C Repair was cytocompatible and promoted mineralized nodule deposition in 21 days and cell migration in 3 days. In conclusion, Bio-C Repair had adequate radiopacity above 3mm Al, solubility less than 3%, dimensional expansion, and low volumetric change. In addition, Bio-C Repair promoted an alkaline pH and presented bioactivity and biocompatibility similar to MTA and Biodentine, showing potential for use as a repair material.


Assuntos
Óxidos , Materiais Restauradores do Canal Radicular , Teste de Materiais , Óxidos/química , Compostos de Cálcio/toxicidade , Compostos de Cálcio/química , Silicatos/toxicidade , Silicatos/química , Combinação de Medicamentos , Compostos de Alumínio/química , Materiais Restauradores do Canal Radicular/toxicidade
14.
Braz. dent. j ; 34(1): 29-38, Jan.-Feb. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1420580

RESUMO

Abstract The aim of this study was to evaluate the physicochemical properties, cytotoxicity and bioactivity of a ready-to-use bioceramic material, Bio-C Repair (Angelus), in comparison with White MTA (Angelus) and Biodentine (Septodont). The physicochemical properties of setting time, radiopacity, pH, solubility, dimensional and volumetric changes were evaluated. Biocompatibility and bioactivity were assessed in Saos-2 osteoblast cell cultures by the MTT assay 3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide), Neutral Red (NR), Alizarin Red (ARS), and cell migration tests. Statistical analysis was performed by ANOVA, Tukey or Bonferroni tests (α = 0.05). Bio-C Repair had the longest setting time (p < 0.05), but radiopacity and solubility were accordance with the ISO 6876/2012 standards, besides linear expansion. Bio-C Repair and MTA had similar volumetric change (p > 0.05); lower than Biodentine (p < 0.05). All the materials evaluated had an alkaline pH. Bio-C Repair was cytocompatible and promoted mineralized nodule deposition in 21 days and cell migration in 3 days. In conclusion, Bio-C Repair had adequate radiopacity above 3mm Al, solubility less than 3%, dimensional expansion, and low volumetric change. In addition, Bio-C Repair promoted an alkaline pH and presented bioactivity and biocompatibility similar to MTA and Biodentine, showing potential for use as a repair material.


Resumo O objetivo deste estudo foi avaliar as propriedades físico-químicas, citotoxicidade e bioatividade de um novo material biocerâmico pronto para uso, Bio-C Repair (Angelus), em comparação com MTA Branco (Angelus) e Biodentine (Septodont). Foram avaliadas as propriedades físico-químicas de tempo de presa, radiopacidade, pH, solubilidade, alterações dimensionais e volumétricas. A biocompatibilidade, bioatividade e capacidade de reparo foram avaliadas em culturas de células de osteoblastos Saos-2 pelo ensaio MTT brometo de 3-(4,5-dimetiltiazol-2-il)-2,5-difeniltetrazólio), vermelho neutro (NR), vermelho de alizarina ( ARS) e testes de migração celular. A análise estatística foi realizada pelos testes ANOVA, Tukey ou Bonferroni (α = 0,05). Bio-C Repair apresentou o maior tempo de presa (p < 0,05), mas radiopacidade e solubilidade de acordo com as normas ISO 6876/2012, além de expansão linear. Bio-C Repair e MTA tiveram variação volumétrica semelhante (p > 0,05), menor que Biodentine (p < 0,05). Todos os materiais avaliados apresentaram pH alcalino. Bio-C Repair foi citocompatível, além de promover deposição de nódulos mineralizados em 21 dias e migração celular em 3 dias. Em conclusão, o Bio-C Repair apresentou radiopacidade adequada acima de 3mmAl, solubilidade menor que 3%, expansão dimensional e baixa perda volumétrica.. Além disso, o Bio-C Repair promoveu um pH alcalino e apresentou bioatividade e biocompatibilidade semelhantes ao MTA e Biodentine, mostrando potencial para uso como material reparador

15.
Online braz. j. nurs. (Online) ; 22: e20236675, 01 jan 2023. ilus, tab
Artigo em Inglês, Português | BDENF - Enfermagem, LILACS | ID: biblio-1524578

RESUMO

OBJETIVO: Elaborar instrumentos para seleção de especialistas para etapas do desenvolvimento de subconjuntos terminológicos da Classificação Internacional para a Prática de Enfermagem (CIPE). MÉTODO: Trata-se de uma pesquisa metodológica. Os critérios identificados, na revisão integrativa da literatura, constituíram base para dois questionários, analisados por 21 avaliadores, em duas rodadas. O primeiro, organizado com seis domínios e 38 critérios, e o segundo, com cinco domínios e 23 critérios, direcionados para etapas do desenvolvimento do subconjunto terminológico. Adotou-se Índice de Validação de Conteúdo ≥ 0,80. RESULTADOS: Os critérios foram alocados em cinco domínios organizadores. Elaborados quatro instrumentos: i) mapeamento cruzado ­ 18 critérios; ii) definição operacional ­ 15 critérios; iii) validação de conteúdo ­ 17 critérios; e iv) aplicabilidade clínica ­ 13 critérios. CONCLUSÃO: Foram elaborados instrumentos com critérios para seleção de especialistas para o desenvolvimento de subconjuntos terminológicos, que se utilizados podem contribuir para o rigor da seleção de especialistas e com a segurança do processo de validação.


OBJECTIVE: To develop tools for selecting experts for stages in developing terminological subsets of the International Classification for Nursing Practice (ICNP). METHOD: This is a methodological research study. The criteria identified in the integrative literature review formed the basis for two questionnaires, analyzed by 21 evaluators in two rounds. The first questionnaire was organized with six domains and 38 criteria, and the second with five domains and 23 criteria, focusing on stages of terminological subset development. A Content Validation Index ≥ 0.80 was adopted. RESULTS: The criteria were allocated into five organizing domains. Four instruments were developed: i) cross-mapping ­ 18 criteria; ii) operational definition ­ 15 criteria; iii) content validation ­ 17 criteria; and iv) clinical applicability ­ 13 criteria. CONCLUSION: Instruments with criteria for selecting experts in the development of terminological subsets were developed, which, if used, can contribute to the rigor of expert selection and the safety of the validation process.


Assuntos
Estudos de Validação como Assunto , Terminologia Padronizada em Enfermagem , Processo de Enfermagem
16.
Enferm. foco (Brasília) ; 13(n.esp1): 1-8, set. 2022. ilus, tab
Artigo em Português | LILACS, BDENF - Enfermagem | ID: biblio-1397107

RESUMO

Objetivo: Analisar a produção da pós-graduação brasileira relacionada à aplicação da teoria de Callista Roy. Métodos: Revisão integrativa, de cunho bibliométrico, com dados de 78 teses e dissertações brasileiras, organizados por ano e tipo de publicação; local geográfico, instituição de ensino e autoria; fomento; especialidade; produção de artigos; especialidade e foco de aplicação. Resultados: Setenta e cinco porcento das teses e dissertações estão disponíveis na íntegra; 27,0% geraram artigos; 39,7% receberam fomento, predominando bolsas; 58,9% são do Nordeste; 37,0% são direcionadas para estomaterapia e pediatria; 48,8% têm como foco o processo de enfermagem e 32,0%, a pessoa em diferentes ciclos da vida. Conclusão: A importante produção da pós-graduação brasileira sobre o tema poderia ser mais visível em artigos. As pesquisas da pós-graduação brasileira oferecem sustentação ao processo de enfermagem direcionado às necessidades de adaptação das pessoas, em distintos ciclos da vida e processo saúde-doença. (AU)


Objective: To analyze the Brazilian graduate production related to the application of Callista Roy's theory. Methods: Integrative review, biblimetric in nature, with data from 78 Brazilian theses and dissertations, organized by year and type of publication; geographic location, educational institution and authorship; promotion; specialty; production of articles; specialty and application focus. Results: Seventy-five percent of theses and dissertations are available in full; 27.0% generated articles; 39.7% received funding, predominantly scholarships; 58.9% are from the Northeast; 37.0% are directed to stomatherapy and pediatrics; 48.8% focus on the nursing process and 32.0%, the person in different life cycles. Conclusion: The important production of Brazilian graduate studies on the subject could be more visible in articles. Brazilian graduate research supports the nursing process aimed at people's adaptation needs, in different life cycles and the healthdisease process. (AU)


Objetivo: Analizar la producción de graduación brasileña relacionada con la aplicación de la teoría de Callista Roy. Métodos: Revisión integradora, de carácter biblimétrico, con datos de 78 tesis y disertaciones brasileñas, organizadas por año y tipo de publicación; ubicación geográfica, institución educativa y autoría; promoción; especialidad; producción de artículos; especialidad y enfoque de aplicación. Resultados: El setenta y cinco por ciento de las tesis y disertaciones están disponibles en su totalidad; 27,0% artículos generados; El 39,7% recibió financiación, predominantemente becas; 58,9% son del Nordeste; El 37,0% se orienta a estomaterapia y pediatría; El 48,8% se centra en el proceso de enfermería y el 32,0%, la persona en diferentes ciclos de vida. Conclusión: La importante producción de estudios de posgrado brasileños sobre el tema podría ser más visible en los artículos. La investigación de posgrado brasileña apoya el proceso de enfermería dirigido a las necesidades de adaptación de las personas, en los diferentes ciclos de vida y el proceso salud-enfermedad. (AU)


Assuntos
Modelos de Enfermagem , Teoria de Enfermagem , Adaptação Fisiológica , Adaptação Psicológica , Bibliometria
17.
Cogit. Enferm. (Online) ; 27: e82955, Curitiba: UFPR, 2022. tab, graf
Artigo em Português | LILACS, BDENF - Enfermagem | ID: biblio-1394316

RESUMO

RESUMO Objetivo: esclarecer os conceitos de violência física, psicológica e sexual e, a partir dos resultados obtidos, comparar similaridades e diferenças entre conceitos, suas características, condições para acontecimentos e possíveis desfechos. Métodos: utilizou-se a análise de conceito evolutivo de Rodgers. Os antecedentes, atributos e consequentes foram extraídos de 91 documentos publicados em 2018, em português, inglês, francês ou espanhol, por busca utilizando os descritores "violência física", "violência psicológica" e "violência sexual". Resultados: para "violência física" foram extraídos 17 atributos, um antecedente e sete consequentes; para "violência sexual" 31 atributos, 10 antecedentes e dois consequentes; e para "violência psicológica" 33 atributos, quatro antecedentes e seis consequentes. Considerações finais: distintas tipologias de violência apresentam diferentes atos que as caracterizam, e que quando (re)conhecidos pelo enfermeiro, oportunizam um planejamento da assistência otimizado e de qualidade.


ABSTRACT Objective: to clarify the concepts of physical, psychological, and sexual violence and, from the results obtained, to compare similarities and differences among concepts, their characteristics, conditions for events, and possible outcomes. Methods: Rodgers' evolving concept analysis was used. The antecedents, attributes and consequents were extracted from 91 documents published in 2018, in Portuguese, English, French or Spanish, by search using the descriptors "physical violence", "psychological violence" and "sexual violence". Results: for "physical violence" 17 attributes, one antecedent and seven consequents were extracted; for "sexual violence" 31 attributes, 10 antecedents and two consequents; and for "psychological violence" 33 attributes, four antecedents and six consequents. Final considerations: different types of violence have different acts that characterize them, and that when (re)known by the nurse, allow for an optimized and quality care planning.


RESUMEN Objetivo: aclarar los conceptos de violencia física, psicológica y sexual y, a partir de los resultados obtenidos, comparar las similitudes y diferencias entre los conceptos, sus características, las condiciones de los acontecimientos y los posibles resultados. Métodos: Se utilizó el análisis conceptual evolutivo de Rodgers. Los antecedentes, atributos y consecuentes se extrajeron de 91 documentos publicados en 2018, en portugués, inglés, francés o español, mediante la búsqueda con los descriptores "violencia física", "violencia psicológica" y "violencia sexual". Resultados: para la "violencia física" se extrajeron 17 atributos, un antecedente y siete consecuentes; para la "violencia sexual" 31 atributos, 10 antecedentes y dos consecuentes; y para la "violencia psicológica" 33 atributos, cuatro antecedentes y seis consecuentes. Consideraciones finales: los diferentes tipos de violencia presentan diferentes actos que los caracterizan, y que al ser (re)conocidos por la enfermera, permiten una planificación de cuidados optimizada y de calidad.


Assuntos
Humanos , Delitos Sexuais/classificação , Abuso Físico/classificação , Abuso Emocional , Formação de Conceito , Vítimas de Crime/classificação , Agressão/classificação , Terminologia Padronizada em Enfermagem
18.
Odovtos (En línea) ; 24(1)abr. 2022.
Artigo em Inglês | LILACS, SaludCR | ID: biblio-1386568

RESUMO

Abstract Cetrimide (CTR) is a cationic surfactant detergent with antimicrobial and antibiofilm activity. The aim of this study was to evaluate setting time, pH, solubility and antibiofilm activity of tricalcium silicate cement (TSC) with zirconium oxide (ZrO2) and its association with 0.2 and 0.4% cetrimide. Initial and final setting times (IST and FST) were assessed based on ISO-6876. pH was evaluated at periods of 1,3,7,14 and 21 days. Solubility was analyzed by weight loss. A modified direct contact test (MDCT) on the biofilm of Enterococcus faecalis formed on bovine root dentin blocks was performed, after 6 hours of manipulation and 15 hours of contact time. The analysis was performed by UFC mL ¯¹ counting. The data were analyzed by ANOVA and Tukey's tests (α=0.05). Higher IST was observed for TSC/ZrO2+CTR in both concentrations than for TSC/ZrO2 and lower FST for TSC/ZrO2+0.4% CTR (p0.05). All materials exhibited increased mass. TSC/ZrO2+CTR 0.4% had lower mass gain than the other materials (p<0.05). The highest antibiofilm activity was observed for TSC/ZrO2+CTR in both concentrations, when compared with the positive control (p<0.05). In conclusion, CTR exhibited potential to promote greater antibiofilm activity to tricalcium silicate cement, without harming its physicochemical properties of setting time, pH and solubility.


Resumen Cetrimida (CTR) es un detergente y surfactante catiónico con actividad antimicrobiana y antibiofilm. El objetivo de este estudio fue evaluar el tiempo de fraguado, pH, solubilidad y actividad antibiofilm del cemento de silicato tricálcico (CST) con óxido de zirconio (ZrO2) y su asociación con CTR a 0.2% y 0.4%. Tiempo de fraguado inicial y final (TFI y TFF) fueron determinados con base en las normas ISO-6876. pH fue evaluado en los períodos de 1,3, 7,14 y 21 días. Solubilidad fue analizada por la pérdida de masa/peso. El test de contacto directo modificado (TCDM) fue realizado sobre biofilm de Enterococcus faecalis formado en dentina radicular bovina, después de 6 horas de manipulación de los cementos y 15 horas de contacto. El análisis fue realizado por la cuantificación de UFC mL¯¹. Los datos fueron analizados usando las pruebas de ANOVA y Tukey (α=0.05). Mayor TFI fue observado para CST/ ZrO2+CTR en las dos concentraciones que para TSC/ZrO2 y menor TFF para TSC/ ZrO2+CTR 0.4% (p0.05). Todos los materiales mostraron aumento de masa. TSC/ZrO2+CTR 0.4% tuvo menor gano de masa que los otros materiales (p<0.05). Mayor actividad antibiofilm fue observado para CST/ZrO2+CTR en las dos concentraciones, cuando comparados con el grupo control positivo (p<0.05). En conclusión, CTR demostró potencial para promover superior actividad antibiofilm al cemento de silicato tricálcico (CST), sin perjudicar sus propiedades físico-químicas de tiempo de fraguado, pH y solubilidad.


Assuntos
Cimento de Silicato/análise , Placa Dentária , Cetrimônio/análise
19.
Restor Dent Endod ; 47(1): e2, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35284328

RESUMO

Objectives: This study investigated the impact of micro-computed tomography (micro-CT)-based voxel size on the analysis of material/dentin interface voids and thickness of different endodontic cements. Materials and Methods: Following root-end resection and apical preparation, maxillary premolars were filled with mineral trioxide aggregate (MTA), Biodentine, and intermediate restorative material (IRM) (n = 24). The samples were scanned using micro-CT (SkyScan 1272; Bruker) and the cement/dentin interface and thickness of materials were evaluated at voxel sizes of 5, 10, and 20 µm. Analysis of variance and the Tukey test were conducted, and the degree of agreement between different voxel sizes was evaluated using the Bland and Altman method (p < 0.05). Results: All materials showed an increase in thickness from 5 to 10 and 20 µm (p < 0.05). When evaluating the interface voids, materials were similar at 5 µm (p > 0.05), while at 10 and 20 µm Biodentine showed the lowest percentage of voids (p < 0.05). A decrease in the interface voids was observed for MTA and IRM at 20 µm, while Biodentine showed differences among all voxel sizes (p < 0.05). The Bland-Altman plots for comparisons among voxel sizes showed the largest deviations when comparing images between 5 and 20 µm. Conclusions: Voxel size had an impact on the micro-CT evaluation of thickness and interface voids of endodontic materials. All cements exhibited an increase in thickness and a decrease in the void percentage as the voxel size increased, especially when evaluating images at 20 µm.

20.
J Biomed Mater Res B Appl Biomater ; 110(4): 862-870, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34808030

RESUMO

This study evaluated the physicochemical and biological properties of novel reparative materials composed of pure tricalcium silicate (Ca3 SiO5 ), Ca3 SiO5 doped with fluoride ions (Ca3 SiO5 -F) and their association with ZrO2 (Ca3 SiO5 + ZrO2 , Ca3 SiO5 -F + ZrO2 ), in comparison with Biodentine (BIO). Setting time radiopacity, pH, solubility, and dimensional change were evaluated based on ISO 6876 Standard. Volumetric change and flow/filling were assessed by microcomputed tomography (micro-CT). Biological properties were evaluated by the MTT assay 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide), Neutral Red (NR), cell migration, alkaline phosphatase activity (ALP), and Alizarin Red Staining (ARS) assays. Statistical analysis was performed by ANOVA, Tukey, or Bonferroni tests (α = .05). Ca3 SiO5 -F + ZrO2 had higher radiopacity, shorter setting time, and lower solubility and volumetric loss than BIO (p < .05). Ca3 SiO5 -F + ZrO2 had flow and filling capacity similar to BIO (p > .05). All the cements evaluated had an alkaline pH. Ca3 SiO5 -F + ZrO2 demonstrated cell viability similar to negative control (p > .05), increase in ALP activity in 7 days, mineralized nodule production in 21 days and repair capacity according to cell migration. In conclusion, Ca3 SiO5 -F + ZrO2 had adequate setting time, radiopacity, solubility, and dimensional change. This material presented low volumetric change besides flow and filling capacity in micro-CT assessment. In addition, Ca3 SiO5 -F + ZrO2 was biocompatible and bioactive, suggesting its use as reparative material.


Assuntos
Fluoretos , Materiais Restauradores do Canal Radicular , Resinas Acrílicas , Compostos de Cálcio/química , Combinação de Medicamentos , Fluoretos/farmacologia , Teste de Materiais , Óxidos/química , Materiais Restauradores do Canal Radicular/química , Silicatos/química , Silicatos/farmacologia , Microtomografia por Raio-X , Zircônio/química , Zircônio/farmacologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA