Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-23797113

RESUMO

A novel, simple and eco-friendly ionic liquid based dispersive liquid-liquid microextraction followed by HPLC determination of anti-hypertensive drugs viz., eprosartan, valasartan, irbesartan, losartan and telmisartan in rat serum has been developed and validated. Experimental parameters influencing the extraction efficiency, nature and volume of the ionic liquid, dispenser solvent, extraction time and effect of salt were optimized. Under the optimum conditions, the extraction recoveries were between 92.85 and 98.50%. The relative standard deviations of intra-and inter-day accuracy varied between 1.9 and 9.1% (n=3). The linearity of the proposed method was 0.1-20µg/mL with coefficients of determination varying between 0.9979 and 0.9992.


Assuntos
Anti-Hipertensivos/sangue , Cromatografia Líquida de Alta Pressão/métodos , Líquidos Iônicos/química , Microextração em Fase Líquida/métodos , Acetona/química , Animais , Anti-Hipertensivos/isolamento & purificação , Imidazóis/química , Ratos , Reprodutibilidade dos Testes , Cloreto de Sódio/química
2.
J Pharm Biomed Anal ; 74: 101-10, 2013 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-23245240

RESUMO

Indinavir sulphate was subjected to forced degradation under hydrolysis (acidic, basic and neutral), oxidation, photolysis and thermal stress as prescribed by ICH guidelines. It was degraded under acidic, basic, neutral and oxidative stress conditions, while it was stable under other conditions. After degradation total eight degradation products were formed. The degradation products were identified and their separation was accomplished on Waters XTerra(®) C(18) column (250 mm × 4.6mm i.d., 5 µm) using 20mM ammonium actate:acetonitrile as (50:50, v/v) mobile phase in an isocratic elution mode by LC. The method was extended to LC-MS/MS for characterization of the degradation products and the fragmentation pathways were proposed. The proposed structures of degradation products were also confirmed by HRMS studies. No previous reports were found in the literature regarding the characterization of degradation products of indinavir sulphate.


Assuntos
Indinavir/análise , Indinavir/química , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida/métodos , Hidrólise , Oxirredução
3.
Artigo em Inglês | MEDLINE | ID: mdl-22770781

RESUMO

A simple and rapid quantitative bioanalytical liquid chromatography-tandem mass spectrometric (LC-MS/MS) method for simultaneous determination of losartan and its active metabolite, losartan carboxylic acid on rat dried blood spots was developed and validated as per regulatory guidelines. Losartan and its metabolite were extracted from dried blood spots using 50% aqueous methanol and separated on Waters XTerra(®) RP18 (250 mm × 4.6 mm, 5 µm) column using mobile phase composed of 40% acetonitrile and 60% aqueous ammonium acetate (10mM). The eluents were monitored using ESI tandem mass spectrometric detection with negative polarity in MRM mode using ion transitions m/z 421.2→179.0, m/z 435.3→157.0 and m/z 427.3→193.0 for losartan, losartan carboxylic acid and Irbesartan (internal standard), respectively. The method was validated over the linear range of 1-200 ng/mL and 5-1000 ng/mL with lower limits of quantification of 1.0 ng/mL and 5.0 ng/mL for losartan and losartan carboxylic acid, respectively. Inter and intra-day precision and accuracy (Bias) were below 5.96% and between -2.8 and 1.5%, respectively. The mean recoveries of the analytes from dried blood spots were between 89% and 97%. No significant carry over and matrix effects were observed. The stability of stock solution, whole blood, dried blood spot and processed samples were tested under different conditions and the results were found to be well within the acceptable limits. Additional validation parameters such as influence of hematocrit and spot volume were also evaluated and found to be well within the acceptable limits.


Assuntos
Cromatografia Líquida/métodos , Teste em Amostras de Sangue Seco/métodos , Losartan/sangue , Espectrometria de Massas em Tandem/métodos , Animais , Estabilidade de Medicamentos , Modelos Lineares , Losartan/análogos & derivados , Losartan/química , Losartan/metabolismo , Metanol , Ratos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Biomed Chromatogr ; 25(11): 1201-7, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21287584

RESUMO

The use of blood spot collection cards is a simple way to obtain specimens for therapeutic drug monitoring, assessing adherence to medications and preventing toxicity in a clinical setting. A high-throughput liquid chromatography-electrospray ionization mass spectrometric (LC-ESI-MS) method for determination of rifaximin on dried blood spots (DBS) was developed and validated. It involves solvent extraction of a punch of DBS followed by reversed-phase LC on a monolithic column consisting of a silica rod with bimodal pore structure and detection by ESI-MS. Rifampicin was used as an internal standard (IS). The run time was within 5.0 min with a very low back-pressure at a flow rate of 0.5 mL/min. The assay was linear from 0.1 to 10 ng/mL. The mean recovery was 98.42%. The developed method is very simple, rapid and useful for clinical applications.


Assuntos
Cromatografia Líquida/métodos , Teste em Amostras de Sangue Seco/métodos , Rifamicinas/sangue , Espectrometria de Massas por Ionização por Electrospray/métodos , Animais , Estabilidade de Medicamentos , Limite de Detecção , Modelos Lineares , Masculino , Ratos , Ratos Wistar , Reprodutibilidade dos Testes , Rifamicinas/química , Rifaximina
5.
J Pharm Biomed Anal ; 54(2): 279-85, 2011 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-20869185

RESUMO

Abacavir sulphate was subjected to forced degradation under the conditions of hydrolysis (acid, alkali and neutral), oxidation, photolysis and thermal stress as prescribed by ICH. Eight degradation products were formed and their separation was accomplished on Waters XTerra C18 (250 mm x 4.6 mm, 5 µm) column using 20 mM ammonium acetate:acetonitrile as a mobile phase in gradient elution mode by LC. The degradation products were characterized by LC-MS/MS and its fragmentation pathways were proposed. No previous reports were found in the literature regarding the degradation behavior of abacavir sulphate.


Assuntos
Didesoxinucleosídeos/química , Inibidores da Transcriptase Reversa/química , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida , Guias como Assunto/normas , Temperatura Alta , Concentração de Íons de Hidrogênio , Hidrólise , Cooperação Internacional , Cinética , Estrutura Molecular , Oxirredução , Fotólise , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
J Pharm Biomed Anal ; 53(4): 833-42, 2010 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-20619992

RESUMO

Forced degradation of ritonavir (RTV), under the conditions of hydrolysis (acidic, basic and neutral), oxidation, photolysis and thermal stress as prescribed by ICH was studied using LC-MS/MS. Eight degradation products were formed and their separation was accomplished on Waters XTerra C(18) column (250 mm x 4.6 mm i.d., 5 microm) using water:methanol:acetonitrile as (40:20:40, v/v/v) mobile phase in an isocratic elution mode by LC. The method was extended to LC-MS/MS for characterization of the degradation products and the pathways of decomposition were proposed. No previous reports were found in the literature regarding the characterization of degradation products of ritonavir.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida/métodos , Inibidores da Protease de HIV/análise , Ritonavir/análise , Espectrometria de Massas em Tandem/métodos , Estabilidade de Medicamentos , Inibidores da Protease de HIV/química , Hidrólise , Ritonavir/química
7.
Biomed Chromatogr ; 23(11): 1145-50, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19444797

RESUMO

A highly sensitive and selective on-line two-dimensional reversed-phase liquid chromatography/electrospray ionization-tandem mass spectrometry (2D-LC-ESI/MS/MS) method was developed and validated to determine rifaximin in rat serum by direct injection. The 2D-LC-ESI/MS/MS system consisted of a restricted access media column for trapping proteins as the first dimension and a Waters C(18 )column as second dimension using 0.1% aqueous acetic acid:acetonitrile as mobile phase in a gradient elution mode. Rifampacin was used as an internal standard. The linear dynamic range was 0.5-10 ng/mL (r(2) > 0.998). Acceptable precision and accuracy were obtained over the calibration range. The assay was successfully used in analysis of rat serum to support pharmacokinetic studies.


Assuntos
Anti-Infecciosos/sangue , Rifamicinas/sangue , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas em Tandem/métodos , Animais , Anti-Infecciosos/farmacocinética , Calibragem , Ratos , Ratos Wistar , Reprodutibilidade dos Testes , Rifamicinas/farmacocinética , Rifaximina , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...