Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-31111183

RESUMO

Albinism is a rare phenotype that affects the pigmentation in eyes, hair, and skin. The effects of albinism in color vision are still unclear. Our study aimed to evaluate the color vision phenotype and genotype of an albino capuchin monkey. An adult albino male capuchin monkey (Sapajus apella) had the L and M opsin gene analyzed, and was trained in a behavioral task of color discrimination. Color discrimination thresholds were determined along 20 chromatic axes around the background chromaticity. A color discrimination ellipse was drawn by interpolation among these thresholds. The albino monkey's behavioral color discrimination ellipse showed poor discrimination along the red-green axis indicating a deutan phenotype. Genetic analysis revealed only the presence of the L gene in the albino monkey. This result did not differ from that obtained with ten previously tested non-albino monkeys. Behavioral and molecular analyses agreed that the albino capuchin monkey had color vision similar to that of non-albino dichromat monkeys, suggesting no influence of albinism on color discrimination.


Assuntos
Albinismo Oculocutâneo/veterinária , Visão de Cores/fisiologia , Sapajus apella/genética , Animais , Genótipo , Masculino , Opsinas/genética , Fenótipo
2.
BMC Evol Biol ; 17(1): 249, 2017 12 11.
Artigo em Inglês | MEDLINE | ID: mdl-29228925

RESUMO

BACKGROUND: Morphological divergences of snake retinal structure point to complex evolutionary processes and adaptations. The Colubridae family has a remarkable variety of retinal structure that can range from all-cone and all-rod to duplex (cone/rod) retinas. To explore whether nocturnal versus diurnal activity is responsible for constraints on molecular evolution and plays a role in visual opsin spectral tuning of colubrids, we carried out molecular evolution analyses of the visual opsin genes LWS, RH1, and SWS1 from 17 species and performed morphological analyses. RESULTS: Phylogenetic reconstructions of the RH1 and LWS recovered major clades characterized by primarily diurnal or primarily nocturnal activity patterns, in contrast with the topology for SWS1, which is very similar to the species tree. We found stronger signals of purifying selection along diurnal and nocturnal lineages for RH1 and SWS1, respectively. A blue-shift of the RH1 spectral peak is associated with diurnal habits. Spectral tuning of cone opsins did not differ among diurnal and nocturnal species. Retinas of nocturnal colubrids had many rows of photoreceptor nuclei, with large numbers of rods, labeled by wheat germ agglutinin (WGA), and two types of cones: large cones sensitive to long/medium wavelengths (L/M) and small cones sensitive to ultra-violet/violet wavelengths (UV/VS). In contrast, retinas of diurnal species had only one row of photoreceptor nuclei, with four types of cones: large and double L/M cones, small UV/VS cones, and a second group of small cones, labeled by WGA. CONCLUSIONS: For LWS gene, selection tests did not confirm different constraints related to activity pattern. For SWS1, stronger purifying selection in nocturnal lineages indicates divergent evolutionary pressures related to the activity pattern, and the importance of the short wavelength sensitivity at low light condition. Activity pattern has a clear influence on the signatures of selection and spectral tuning of RH1, with stronger purifying selection in diurnal lineages, which indicates selective pressure to preserve rhodopsin structure and function in pure-cone retinas. We suggest that the presence of four cone types in primarily diurnal colubrids might be related to the gain of color discrimination capacity.


Assuntos
Colubridae/genética , Colubridae/fisiologia , Evolução Molecular , Opsinas/genética , Retina/anatomia & histologia , Seleção Genética , Animais , Funções Verossimilhança , Filogenia
3.
Braz J Med Biol Res ; 46(2): 154-63, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23369980

RESUMO

The purpose of the present study was to measure contrast sensitivity to equiluminant gratings using steady-state visual evoked cortical potential (ssVECP) and psychophysics. Six healthy volunteers were evaluated with ssVECPs and psychophysics. The visual stimuli were red-green or blue-yellow horizontal sinusoidal gratings, 5° × 5°, 34.3 cd/m2 mean luminance, presented at 6 Hz. Eight spatial frequencies from 0.2 to 8 cpd were used, each presented at 8 contrast levels. Contrast threshold was obtained by extrapolating second harmonic amplitude values to zero. Psychophysical contrast thresholds were measured using stimuli at 6 Hz and static presentation. Contrast sensitivity was calculated as the inverse function of the pooled cone contrast threshold. ssVECP and both psychophysical contrast sensitivity functions (CSFs) were low-pass functions for red-green gratings. For electrophysiology, the highest contrast sensitivity values were found at 0.4 cpd (1.95 ± 0.15). ssVECP CSF was similar to dynamic psychophysical CSF, while static CSF had higher values ranging from 0.4 to 6 cpd (P < 0.05, ANOVA). Blue-yellow chromatic functions showed no specific tuning shape; however, at high spatial frequencies the evoked potentials showed higher contrast sensitivity than the psychophysical methods (P < 0.05, ANOVA). Evoked potentials can be used reliably to evaluate chromatic red-green CSFs in agreement with psychophysical thresholds, mainly if the same temporal properties are applied to the stimulus. For blue-yellow CSF, correlation between electrophysiology and psychophysics was poor at high spatial frequency, possibly due to a greater effect of chromatic aberration on this kind of stimulus.


Assuntos
Sensibilidades de Contraste/fisiologia , Potenciais Evocados Visuais/fisiologia , Reconhecimento Visual de Modelos/fisiologia , Adulto , Percepção de Cores/fisiologia , Eletrofisiologia , Feminino , Humanos , Masculino , Estimulação Luminosa , Psicofísica
4.
Braz. j. med. biol. res ; 46(2): 154-163, 01/fev. 2013. tab, graf
Artigo em Inglês | LILACS | ID: lil-668780

RESUMO

The purpose of the present study was to measure contrast sensitivity to equiluminant gratings using steady-state visual evoked cortical potential (ssVECP) and psychophysics. Six healthy volunteers were evaluated with ssVECPs and psychophysics. The visual stimuli were red-green or blue-yellow horizontal sinusoidal gratings, 5° × 5°, 34.3 cd/m2 mean luminance, presented at 6 Hz. Eight spatial frequencies from 0.2 to 8 cpd were used, each presented at 8 contrast levels. Contrast threshold was obtained by extrapolating second harmonic amplitude values to zero. Psychophysical contrast thresholds were measured using stimuli at 6 Hz and static presentation. Contrast sensitivity was calculated as the inverse function of the pooled cone contrast threshold. ssVECP and both psychophysical contrast sensitivity functions (CSFs) were low-pass functions for red-green gratings. For electrophysiology, the highest contrast sensitivity values were found at 0.4 cpd (1.95 ± 0.15). ssVECP CSF was similar to dynamic psychophysical CSF, while static CSF had higher values ranging from 0.4 to 6 cpd (P < 0.05, ANOVA). Blue-yellow chromatic functions showed no specific tuning shape; however, at high spatial frequencies the evoked potentials showed higher contrast sensitivity than the psychophysical methods (P < 0.05, ANOVA). Evoked potentials can be used reliably to evaluate chromatic red-green CSFs in agreement with psychophysical thresholds, mainly if the same temporal properties are applied to the stimulus. For blue-yellow CSF, correlation between electrophysiology and psychophysics was poor at high spatial frequency, possibly due to a greater effect of chromatic aberration on this kind of stimulus.


Assuntos
Adulto , Feminino , Humanos , Masculino , Sensibilidades de Contraste/fisiologia , Potenciais Evocados Visuais/fisiologia , Reconhecimento Visual de Modelos/fisiologia , Percepção de Cores/fisiologia , Eletrofisiologia , Estimulação Luminosa , Psicofísica
5.
Braz. j. med. biol. res ; 45(10): 955-961, Oct. 2012. ilus, tab
Artigo em Inglês | LILACS | ID: lil-647757

RESUMO

This study compared the effectiveness of the multifocal visual evoked cortical potentials (mfVEP) elicited by pattern pulse stimulation with that of pattern reversal in producing reliable responses (signal-to-noise ratio >1.359). Participants were 14 healthy subjects. Visual stimulation was obtained using a 60-sector dartboard display consisting of 6 concentric rings presented in either pulse or reversal mode. Each sector, consisting of 16 checks at 99% Michelson contrast and 80 cd/m² mean luminance, was controlled by a binary m-sequence in the time domain. The signal-to-noise ratio was generally larger in the pattern reversal than in the pattern pulse mode. The number of reliable responses was similar in the central sectors for the two stimulation modes. At the periphery, pattern reversal showed a larger number of reliable responses. Pattern pulse stimuli performed similarly to pattern reversal stimuli to generate reliable waveforms in R1 and R2. The advantage of using both protocols to study mfVEP responses is their complementarity: in some patients, reliable waveforms in specific sectors may be obtained with only one of the two methods. The joint analysis of pattern reversal and pattern pulse stimuli increased the rate of reliability for central sectors by 7.14% in R1, 5.35% in R2, 4.76% in R3, 3.57% in R4, 2.97% in R5, and 1.78% in R6. From R1 to R4 the reliability to generate mfVEPs was above 70% when using both protocols. Thus, for a very high reliability and thorough examination of visual performance, it is recommended to use both stimulation protocols.


Assuntos
Adulto , Humanos , Potenciais Evocados Visuais/fisiologia , Reconhecimento Visual de Modelos/fisiologia , Estimulação Luminosa/métodos , Reprodutibilidade dos Testes , Percepção Espacial/fisiologia , Percepção do Tempo , Córtex Visual/fisiologia , Campos Visuais/fisiologia
6.
Braz J Med Biol Res ; 45(10): 955-61, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22782556

RESUMO

This study compared the effectiveness of the multifocal visual evoked cortical potentials (mfVEP) elicited by pattern pulse stimulation with that of pattern reversal in producing reliable responses (signal-to-noise ratio >1.359). Participants were 14 healthy subjects. Visual stimulation was obtained using a 60-sector dartboard display consisting of 6 concentric rings presented in either pulse or reversal mode. Each sector, consisting of 16 checks at 99% Michelson contrast and 80 cd/m² mean luminance, was controlled by a binary m-sequence in the time domain. The signal-to-noise ratio was generally larger in the pattern reversal than in the pattern pulse mode. The number of reliable responses was similar in the central sectors for the two stimulation modes. At the periphery, pattern reversal showed a larger number of reliable responses. Pattern pulse stimuli performed similarly to pattern reversal stimuli to generate reliable waveforms in R1 and R2. The advantage of using both protocols to study mfVEP responses is their complementarity: in some patients, reliable waveforms in specific sectors may be obtained with only one of the two methods. The joint analysis of pattern reversal and pattern pulse stimuli increased the rate of reliability for central sectors by 7.14% in R1, 5.35% in R2, 4.76% in R3, 3.57% in R4, 2.97% in R5, and 1.78% in R6. From R1 to R4 the reliability to generate mfVEPs was above 70% when using both protocols. Thus, for a very high reliability and thorough examination of visual performance, it is recommended to use both stimulation protocols.


Assuntos
Potenciais Evocados Visuais/fisiologia , Reconhecimento Visual de Modelos/fisiologia , Estimulação Luminosa/métodos , Adulto , Humanos , Reprodutibilidade dos Testes , Percepção Espacial/fisiologia , Percepção do Tempo , Córtex Visual/fisiologia , Campos Visuais/fisiologia
7.
Ophthalmic Physiol Opt ; 30(5): 518-24, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20883335

RESUMO

Transient visual evoked cortical potentials (VECP) were recorded from the scalp of healthy normal trichromats (n = 12). VECPs were elicited by onset/offset presentation of patterned stimuli of two kinds: isochromatic luminance-modulated, and equiluminant red-green modulated, sine wave gratings. The amplitude and latency of the major onset components of the onset/offset VECP were measured and plotted as a function of the logarithm of pooled cone contrast. The early onset components, achromatic C1 and chromatic N1, increase linearly with log contrast, but N1 has a higher contrast gain than C1. The late onset components, achromatic C2 and chromatic N2, have similar contrast gain, and similar response as a function of contrast level: both increase in the low-to-medium range of contrasts and saturate at high contrast levels. In the range of pooled cone contrast tested, C1 and N1 show similar latencies, whilst C2 shows shorter latencies than N2. We suggest that C1 and N1 are generated by the same visual mechanism with high red-green contrast gain and low luminance contrast gain, whilst C2 and N2 are generated by different visual mechanisms.


Assuntos
Percepção de Cores/fisiologia , Sensibilidades de Contraste/fisiologia , Potenciais Evocados Visuais/fisiologia , Células Fotorreceptoras Retinianas Cones/fisiologia , Adulto , Feminino , Humanos , Masculino , Estimulação Luminosa/métodos , Psicofísica , Tempo de Reação/fisiologia , Adulto Jovem
8.
Vis Neurosci ; 25(3): 307-15, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18598402

RESUMO

The turtle retina has been extensively used for the study of chromatic processing mechanisms. Color opponency has been previously investigated with trichromatic paradigms, but behavioral studies show that the turtle has an ultraviolet (UV) channel and a tetrachromatic visual system. Our laboratory has been working in the characterization of neuronal responses in the retina of vertebrates using stimuli in the UV-visible range of the electromagnetic spectrum. In the present investigation, we recorded color-opponent responses from turtle amacrine and ganglion cells to UV and visible stimuli and extended our previous results that UV color-opponency is present at the level of the inner nuclear layer. We recorded from 181 neurons, 36 of which were spectrally opponent. Among these, there were 10 amacrine (5%), and 26 ganglion cells (15%). Morphological identification of color-opponent neurons was possible for two ganglion cell classes (G17 and G22) and two amacrine cell classes (A22 and A23b). There was a variety of cell response types and a potential for complex processing of chromatic stimuli, with intensity- and wavelength-dependent response components. Ten types of color opponency were found in ganglion cells and by adding previous results from our laboratory, 12 types of opponent responses have been found. The majority of the ganglion cells were R+UVBG- and RG+UVB-color-opponents but there were other less frequent types of chromatic opponency. This study confirms the participation of a UV channel in the processing of color opponency in the turtle inner retina and shows that the turtle visual system has the retinal mechanisms to allow many possible chromatic combinations.


Assuntos
Percepção de Cores/fisiologia , Células Ganglionares da Retina/citologia , Células Ganglionares da Retina/fisiologia , Vias Visuais/fisiologia , Animais , Gânglios dos Invertebrados/fisiologia , Microscopia Confocal , Microscopia de Fluorescência , Neurônios/fisiologia , Células Fotorreceptoras Retinianas Cones/fisiologia , Tartarugas , Raios Ultravioleta
9.
Vis Neurosci ; 25(3): 469-74, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18598420

RESUMO

We examined achromatic contrast discrimination in asymptomatic carriers of 11778 Leber's hereditary optic neuropathy (LHON 18 controls) and 18 age-match were also tested. To evaluate magnocellular (MC) and Parvocellular (PC) contrast discrimination, we used a version of Pokorny and Smith's (1997) pulsed/steady-pedestal paradigms (PPP/SPP) thought to be detected via PC and MC pathways, respectively. A luminance pedestal (four 1 degree x 1 degree squares) was presented on a 12 cd/m2 surround. The luminance of one of the squares (trial square, TS) was randomly incremented for either 17 or 133 ms. Observers had to detect the TS, in a forced-choice task, at each duration, for three pedestal levels: 7, 12, 19 cd/m2. In the SPP, the pedestal was fixed, and the TS was modulated. For the PPP, all four pedestal squares pulsed for 17 or 133 ms, and the TS was simultaneously incremented or decremented. We found that contrast discrimination thresholds of LHON carriers were significantly higher than controls' in the condition with the highest luminance of both paradigms, implying impaired contrast processing with no evidence of differential sensitivity losses between the two systems. Carriers' thresholds manifested significantly longer temporal integration than controls in the SPP, consistent with slowed MC responses. The SPP and PPP paradigms can identify contrast and temporal processing deficits in asymptomatic LHON carriers, and thus provide an additional tool for early detection and characterization of the disease.


Assuntos
Sensibilidades de Contraste , Triagem de Portadores Genéticos , Atrofia Óptica Hereditária de Leber/genética , Adolescente , Adulto , Discriminação Psicológica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Testes Visuais , Acuidade Visual , Vias Visuais
10.
Braz J Med Biol Res ; 40(3): 415-24, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17334540

RESUMO

We measured visual performance in achromatic and chromatic spatial tasks of mercury-exposed subjects and compared the results with norms obtained from healthy individuals of similar age. Data were obtained for a group of 28 mercury-exposed subjects, comprising 20 Amazonian gold miners, 2 inhabitants of Amazonian riverside communities, and 6 laboratory technicians, who asked for medical care. Statistical norms were generated by testing healthy control subjects divided into three age groups. The performance of a substantial proportion of the mercury-exposed subjects was below the norms in all of these tasks. Eleven of 20 subjects (55%) performed below the norms in the achromatic contrast sensitivity task. The mercury-exposed subjects also had lower red-green contrast sensitivity deficits at all tested spatial frequencies (9/11 subjects; 81%). Three gold miners and 1 riverine (4/19 subjects, 21%) performed worse than normal subjects making more mistakes in the color arrangement test. Five of 10 subjects tested (50%), comprising 2 gold miners, 2 technicians, and 1 riverine, performed worse than normal in the color discrimination test, having areas of one or more MacAdam ellipse larger than normal subjects and high color discrimination thresholds at least in one color locus. These data indicate that psychophysical assessment can be used to quantify the degree of visual impairment of mercury-exposed subjects. They also suggest that some spatial tests such as the measurement of red-green chromatic contrast are sufficiently sensitive to detect visual dysfunction caused by mercury toxicity.


Assuntos
Percepção de Cores/efeitos dos fármacos , Defeitos da Visão Cromática/induzido quimicamente , Sensibilidades de Contraste/efeitos dos fármacos , Mercúrio/toxicidade , Doenças Profissionais/induzido quimicamente , Exposição Ocupacional/efeitos adversos , Adolescente , Adulto , Idoso , Brasil , Estudos de Casos e Controles , Defeitos da Visão Cromática/diagnóstico , Exposição Ambiental/efeitos adversos , Poluentes Ambientais , Humanos , Masculino , Pessoal de Laboratório Médico , Mercúrio/urina , Pessoa de Meia-Idade , Mineração , Doenças Profissionais/diagnóstico , Espectrofotometria Atômica , Fatores de Tempo
11.
Braz J Med Biol Res ; 40(3): 409-14, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17334539

RESUMO

We evaluated the color vision of 24 subjects (41.6 +/- 6.5 years; 6 females) who worked in fluorescent lamp industries. They had been occupationally exposed to mercury vapor (10.6 +/- 5.2 years) and had been away from the source of exposure for 6.4 +/- 4.04 years. Mean urinary concentration of mercury was 40.6 +/- 36.4 microg/g creatinine during or up to 1 year after exposure and 2.71 +/- 1.19 microg/g creatinine at the time of color vision testing or up to 1 year thereafter. All patients were diagnosed with chronic mercury intoxication, characterized by clinical symptoms and neuropsychological alterations. A control group (N = 36, 48.6 +/- 11.9 years, 10 females, 1.5 +/- 0.47 microg mercury/g creatinine) was subjected to the same tests. Inclusion criteria for both groups were Snellen VA 20/30 or better and absence of known ophthalmologic pathologies. Color discrimination was assessed with the Farnsworth D-15 test (D-15) and with the Lanthony D-15d test (D-15d). Significant differences were found between the two eyes of the patients (P < 0.001) in both tests. Results for the worst eye were also different from controls for both tests: P = 0.014 for D-15 and P < 0.001 for D-15d. As shown in previous studies, the D-15d proved to be more sensitive than the D-15 for the screening and diagnosis of the color discrimination losses. Since color discrimination losses were still present many years after the end of exposure, they may be considered to be irreversible, at least under the conditions of the present study.


Assuntos
Defeitos da Visão Cromática/induzido quimicamente , Exposição por Inalação/efeitos adversos , Mercúrio/toxicidade , Doenças Profissionais/induzido quimicamente , Exposição Ocupacional/efeitos adversos , Adulto , Percepção de Cores/efeitos dos fármacos , Defeitos da Visão Cromática/diagnóstico , Feminino , Humanos , Masculino , Doenças Profissionais/diagnóstico , Fatores de Tempo
12.
Braz. j. med. biol. res ; 40(3): 415-424, Mar. 2007. tab
Artigo em Inglês | LILACS | ID: lil-441755

RESUMO

We measured visual performance in achromatic and chromatic spatial tasks of mercury-exposed subjects and compared the results with norms obtained from healthy individuals of similar age. Data were obtained for a group of 28 mercury-exposed subjects, comprising 20 Amazonian gold miners, 2 inhabitants of Amazonian riverside communities, and 6 laboratory technicians, who asked for medical care. Statistical norms were generated by testing healthy control subjects divided into three age groups. The performance of a substantial proportion of the mercury-exposed subjects was below the norms in all of these tasks. Eleven of 20 subjects (55 percent) performed below the norms in the achromatic contrast sensitivity task. The mercury-exposed subjects also had lower red-green contrast sensitivity deficits at all tested spatial frequencies (9/11 subjects; 81 percent). Three gold miners and 1 riverine (4/19 subjects, 21 percent) performed worse than normal subjects making more mistakes in the color arrangement test. Five of 10 subjects tested (50 percent), comprising 2 gold miners, 2 technicians, and 1 riverine, performed worse than normal in the color discrimination test, having areas of one or more MacAdam ellipse larger than normal subjects and high color discrimination thresholds at least in one color locus. These data indicate that psychophysical assessment can be used to quantify the degree of visual impairment of mercury-exposed subjects. They also suggest that some spatial tests such as the measurement of red-green chromatic contrast are sufficiently sensitive to detect visual dysfunction caused by mercury toxicity.


Assuntos
Humanos , Masculino , Adolescente , Adulto , Pessoa de Meia-Idade , Percepção de Cores/efeitos dos fármacos , Defeitos da Visão Cromática/induzido quimicamente , Sensibilidades de Contraste/efeitos dos fármacos , Mercúrio/toxicidade , Doenças Profissionais/induzido quimicamente , Exposição Ocupacional/efeitos adversos , Brasil , Estudos de Casos e Controles , Defeitos da Visão Cromática/diagnóstico , Poluentes Ambientais , Exposição Ambiental/efeitos adversos , Pessoal de Laboratório , Mineração , Mercúrio/urina , Doenças Profissionais/diagnóstico , Espectrofotometria Atômica , Fatores de Tempo
13.
Braz. j. med. biol. res ; 40(3): 409-414, Mar. 2007. tab, graf
Artigo em Inglês | LILACS | ID: lil-441768

RESUMO

We evaluated the color vision of 24 subjects (41.6 ± 6.5 years; 6 females) who worked in fluorescent lamp industries. They had been occupationally exposed to mercury vapor (10.6 ± 5.2 years) and had been away from the source of exposure for 6.4 ± 4.04 years. Mean urinary concentration of mercury was 40.6 ± 36.4 æg/g creatinine during or up to 1 year after exposure and 2.71 ± 1.19 æg/g creatinine at the time of color vision testing or up to 1 year thereafter. All patients were diagnosed with chronic mercury intoxication, characterized by clinical symptoms and neuropsychological alterations. A control group (N = 36, 48.6 ± 11.9 years, 10 females, 1.5 ± 0.47 æg mercury/g creatinine) was subjected to the same tests. Inclusion criteria for both groups were Snellen VA 20/30 or better and absence of known ophthalmologic pathologies. Color discrimination was assessed with the Farnsworth D-15 test (D-15) and with the Lanthony D-15d test (D-15d). Significant differences were found between the two eyes of the patients (P < 0.001) in both tests. Results for the worst eye were also different from controls for both tests: P = 0.014 for D-15 and P < 0.001 for D-15d. As shown in previous studies, the D-15d proved to be more sensitive than the D-15 for the screening and diagnosis of the color discrimination losses. Since color discrimination losses were still present many years after the end of exposure, they may be considered to be irreversible, at least under the conditions of the present study.


Assuntos
Humanos , Masculino , Feminino , Adulto , Defeitos da Visão Cromática/induzido quimicamente , Exposição por Inalação/efeitos adversos , Mercúrio/toxicidade , Doenças Profissionais/induzido quimicamente , Exposição Ocupacional/efeitos adversos , Percepção de Cores/efeitos dos fármacos , Defeitos da Visão Cromática/diagnóstico , Doenças Profissionais/diagnóstico , Fatores de Tempo
14.
Braz. j. med. biol. res ; 40(3): 425-433, Mar. 2007. tab, graf
Artigo em Inglês | LILACS | ID: lil-441771

RESUMO

We assessed the neuropsychological test performances of 26 patients (mean age = 41.5 ± 6.1 years; mean years of education = 9.8 ± 1.8; 20 males) diagnosed with chronic occupational mercurialism who were former workers at a fluorescent lamp factory. They had been exposed to elemental mercury for an average of 10.2 ± 3.8 years and had been away from this work for 6 ± 4.7 years. Mean urinary mercury concentrations 1 year after cessation of work were 1.8 ± 0.9 æg/g creatinine. Twenty control subjects matched for age, gender, and education (18 males) were used for comparison. Neuropsychological assessment included attention, inhibitory control, verbal and visual memory, verbal fluency, manual dexterity, visual-spatial function, executive function, and semantic knowledge tests. The Beck Depression Inventory and the State and Trait Inventory were used to assess depression and anxiety symptoms, respectively. The raw score for the group exposed to mercury indicated slower information processing speed, inferior performance in psychomotor speed, verbal spontaneous recall memory, and manual dexterity of the dominant hand and non-dominant hand (P < 0.05). In addition, the patients showed increased depression and anxiety symptoms (P < 0.001). A statistically significant correlation (Pearson) was demonstrable between mean urinary mercury and anxiety trait (r = 0.75, P = 0.03). The neuropsychological performances of the former workers suggest that occupational exposure to elemental mercury has long-term effects on information processing and psychomotor function, with increased depression and anxiety also possibly reflecting the psychosocial context.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Exposição por Inalação/efeitos adversos , Transtornos Mentais/induzido quimicamente , Transtornos Mentais/etiologia , Mercúrio/toxicidade , Doenças Profissionais/induzido quimicamente , Exposição Ocupacional/efeitos adversos , Transtornos Psicomotores/induzido quimicamente , Atenção/efeitos dos fármacos , Estudos de Casos e Controles , Memória/efeitos dos fármacos , Transtornos Mentais/diagnóstico , Mercúrio/urina , Testes Neuropsicológicos , Doenças Profissionais/diagnóstico , Transtornos Psicomotores/diagnóstico , Fatores de Tempo
15.
Ecotoxicol Environ Saf ; 68(3): 426-35, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17296226

RESUMO

Methylmercury is a potent toxic present in Amazonian fish species due to gold mining activities. In the present work, we investigated the morphological effects of methylmercury in liver and kidney of Hoplias malabaricus feeding contaminated prey fish over 70 days. Two groups of nine mature fish (tested and control) were acclimatized for four weeks to laboratory conditions and then the tested group fed prey fish previously contaminated at an additional level of 0.075 microg MeHg g(-1) at 5-day intervals and over 14 successive intervals whereas control group fed uncontaminated fish. H. malabaricus specimens were then dissected for chemical and morphological analyses. The low and realistic level of MeHg in the prey fish induced a low increase of total mercury in liver (1.8-fold) and muscle (2.2-fold). The biomagnification factor (Hg in predator/Hg in prey) reached 142 in liver and 21 in muscle and was indicative of a relatively fast contamination of internal organs by dietary exposure. The liver of exposed individuals presented leukocyte infiltration, increased number of melano-macrophage centers, necrotic areas and lesions in Disse's space. Evident disorder and chaos in cytoskeleton organization suggest a strong toxic effect in hepatocytes, such as organelles positioning and movement, vesicles traffic and secretion. Head kidney showed large necrosis areas, increased number of melano-macrophages centers, phagocytic areas, intercellular space among parenquimal cells and atypical cells. Injuries and damages to tissues suggest too slow defense mechanisms to immobilize or eliminate ingested methylmercury, demonstrating that the sensitivity of fish cells to methylmercury exposure is higher than it has been previously described in the literature.


Assuntos
Peixes , Rim/efeitos dos fármacos , Fígado/efeitos dos fármacos , Compostos de Metilmercúrio/toxicidade , Poluentes Químicos da Água/toxicidade , Animais , Brasil , Dieta , Cadeia Alimentar , Contaminação de Alimentos , Rim/metabolismo , Rim/patologia , Fígado/metabolismo , Fígado/patologia , Compostos de Metilmercúrio/administração & dosagem , Compostos de Metilmercúrio/metabolismo , Fatores de Tempo , Clima Tropical , Poluentes Químicos da Água/administração & dosagem , Poluentes Químicos da Água/metabolismo
16.
Braz J Med Biol Res ; 39(7): 987-95, 2006 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16862290

RESUMO

Methyl mercury (MeHg) is highly neurotoxic, affecting visual function in addition to other central nervous system functions. The effect of mercury intoxication on the amplitude of horizontal cell responses to light was studied in the retina of the fish Hoplias malabaricus. Intracellular responses were recorded from horizontal cells of fish previously intoxicated with MeHg by intraperitoneal injection (IP group) or by trophic exposure (T group). Only one retina per fish was used. The doses of MeHg chloride administered to the IP group were 0.01, 0.05, 0.1, 1.0, 2.0, and 6.0 mg/kg. The amplitudes of the horizontal cell responses were lower than control in individuals exposed to 0.01 (N = 4 retinas), 0.05 (N = 2 retinas) and 0.1 mg/kg (N = 1 retina), whereas no responses were recorded in the 1.0, 2.0, and 6.0 mg/kg groups. T group individuals were fed young specimens of Astyanax sp previously injected with MeHg corresponding to 0.75 (N = 1 retina), 0.075 (N = 8 retinas) or 0.0075 (N = 4 retinas) mg/kg fish body weight. After 14 doses, one every 5 days, the amplitude of the horizontal cell response was higher than control in individuals exposed to 0.075 and 0.0075 mg/kg, and lower in individuals exposed to 0.75 mg/kg. We conclude that intoxication with MeHg affects the electrophysiological response of the horizontal cells in the retina, either reducing or increasing its amplitude compared to control, and that these effects are related to the dose and/or to the mode of administration.


Assuntos
Peixes , Compostos de Metilmercúrio/toxicidade , Células Horizontais da Retina/efeitos dos fármacos , Animais , Relação Dose-Resposta a Droga , Eletrofisiologia , Compostos de Metilmercúrio/administração & dosagem , Células Horizontais da Retina/fisiologia
17.
Braz. j. med. biol. res ; 39(7): 987-995, July 2006. ilus
Artigo em Inglês | LILACS | ID: lil-431556

RESUMO

Methyl mercury (MeHg) is highly neurotoxic, affecting visual function in addition to other central nervous system functions. The effect of mercury intoxication on the amplitude of horizontal cell responses to light was studied in the retina of the fish Hoplias malabaricus. Intracellular responses were recorded from horizontal cells of fish previously intoxicated with MeHg by intraperitoneal injection (IP group) or by trophic exposure (T group). Only one retina per fish was used. The doses of MeHg chloride administered to the IP group were 0.01, 0.05, 0.1, 1.0, 2.0, and 6.0 mg/kg. The amplitudes of the horizontal cell responses were lower than control in individuals exposed to 0.01 (N = 4 retinas), 0.05 (N = 2 retinas) and 0.1 mg/kg (N = 1 retina), whereas no responses were recorded in the 1.0, 2.0, and 6.0 mg/kg groups. T group individuals were fed young specimens of Astyanax sp previously injected with MeHg corresponding to 0.75 (N = 1 retina), 0.075 (N = 8 retinas) or 0.0075 (N = 4 retinas) mg/kg fish body weight. After 14 doses, one every 5 days, the amplitude of the horizontal cell response was higher than control in individuals exposed to 0.075 and 0.0075 mg/kg, and lower in individuals exposed to 0.75 mg/kg. We conclude that intoxication with MeHg affects the electrophysiological response of the horizontal cells in the retina, either reducing or increasing its amplitude compared to control, and that these effects are related to the dose and/or to the mode of administration.


Assuntos
Animais , Peixes , Compostos de Metilmercúrio/toxicidade , Células Horizontais da Retina/efeitos dos fármacos , Relação Dose-Resposta a Droga , Eletrofisiologia , Compostos de Metilmercúrio/administração & dosagem , Células Horizontais da Retina/fisiologia
18.
Braz. j. med. biol. res ; 39(3): 405-410, Mar. 2006. ilus
Artigo em Inglês | LILACS | ID: lil-421368

RESUMO

To quantify the effects of methylmercury (MeHg) on amacrine and on ON-bipolar cells in the retina, experiments were performed in MeHg-exposed groups of adult trahiras (Hoplias malabaricus) at two dose levels (2 and 6 µg/g, ip). The retinas of test and control groups were processed by mouse anti-parvalbumin and rabbit anti-alphaprotein kinase C (alphaPKC) immunocytochemistry. Morphology and soma location in the inner nuclear layer were used to identify immunoreactive parvalbumin (PV-IR) and alphaPKC (alphaPKC-IR) in wholemount preparations. Cell density, topography and isodensity maps were estimated using confocal images. PV-IR was detected in amacrine cells in the inner nuclear layer and in displaced amacrine cells from the ganglion cell layer, and alphaPKC-IR was detected in ON-bipolar cells. The MeHg-treated group (6 µg/g) showed significant reduction of the ON-bipolar alphaPKC-IR cell density (mean density = 1306 ± 393 cells/mm²) compared to control (1886 ± 892 cells/mm²; P < 0.001). The mean densities found for amacrine PV-IR cells in MeHg-treated retinas were 1040 ± 56 cells/mm² (2 µg/g) and 845 ± 82 cells/mm² (6 µg/g), also lower than control (1312 ± 31 cells/mm²; P < 0.05), differently from the data observed in displaced PV-IR amacrine cells. These results show that MeHg changed the PV-IR amacrine cell density in a dose-dependent way, and reduced the density of alphaKC-IR bipolar cells at the dose of 6 µg/g. Further studies are needed to identify the physiological impact of these findings on visual function.


Assuntos
Animais , Células Amácrinas/efeitos dos fármacos , Peixes/metabolismo , Compostos de Metilmercúrio/toxicidade , Parvalbuminas/efeitos dos fármacos , Proteína Quinase C-alfa/efeitos dos fármacos , Células Bipolares da Retina/efeitos dos fármacos , Células Amácrinas/metabolismo , Parvalbuminas/metabolismo , Proteína Quinase C-alfa/metabolismo , Células Bipolares da Retina/metabolismo
19.
Braz J Med Biol Res ; 39(3): 405-10, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16501820

RESUMO

To quantify the effects of methylmercury (MeHg) on amacrine and on ON-bipolar cells in the retina, experiments were performed in MeHg-exposed groups of adult trahiras (Hoplias malabaricus) at two dose levels (2 and 6 microg/g, ip). The retinas of test and control groups were processed by mouse anti-parvalbumin and rabbit anti-alphaprotein kinase C (alphaPKC) immunocytochemistry. Morphology and soma location in the inner nuclear layer were used to identify immunoreactive parvalbumin (PV-IR) and alphaPKC (alphaPKC-IR) in wholemount preparations. Cell density, topography and isodensity maps were estimated using confocal images. PV-IR was detected in amacrine cells in the inner nuclear layer and in displaced amacrine cells from the ganglion cell layer, and alphaPKC-IR was detected in ON-bipolar cells. The MeHg-treated group (6 microg/g) showed significant reduction of the ON-bipolar alphaPKC-IR cell density (mean density = 1306 +/- 393 cells/mm2) compared to control (1886 +/- 892 cells/mm2; P < 0.001). The mean densities found for amacrine PV-IR cells in MeHg-treated retinas were 1040 +/- 56 cells/mm2 (2 microg/g) and 845 +/- 82 cells/mm2 (6 microg/g), also lower than control (1312 +/- 31 cells/mm2; P < 0.05), differently from the data observed in displaced PV-IR amacrine cells. These results show that MeHg changed the PV-IR amacrine cell density in a dose-dependent way, and reduced the density of alphaKC-IR bipolar cells at the dose of 6 microg/g. Further studies are needed to identify the physiological impact of these findings on visual function.


Assuntos
Células Amácrinas/efeitos dos fármacos , Peixes/metabolismo , Compostos de Metilmercúrio/toxicidade , Parvalbuminas/efeitos dos fármacos , Proteína Quinase C-alfa/efeitos dos fármacos , Células Bipolares da Retina/efeitos dos fármacos , Células Amácrinas/metabolismo , Animais , Parvalbuminas/metabolismo , Proteína Quinase C-alfa/metabolismo , Células Bipolares da Retina/metabolismo
20.
Environ Toxicol Pharmacol ; 19(3): 523-9, 2005 May.
Artigo em Inglês | MEDLINE | ID: mdl-21783522

RESUMO

We evaluated vision loss in workers from fluorescent lamp industries (n=39) who had retired due to intoxication with mercury vapour and had been away from the work situation for several years (mean=6.32 years). An age-matched control group was submitted to the same tests for comparison. The luminance contrast sensitivity (CSF) was measured psychophysically and with the sweep visual evoked potential (sVEP) method. Chromatic red-green and blue-yellow CSFs were measured psychophysically. Colour discrimination was assessed with the Farnsworth-Munsell 100-hue test, Lanthony D-15d test and Cambridge Colour Vision Test. Patient data showed significantly lower scores in all colour tests compared to controls (p<.001). The behavioural luminance CSF of the patients was lower than that of controls (p<.001 at all frequencies tested). This result was confirmed by the electrophysiologically measured sweep VEP luminance CSF except at the highest frequencies-a difference that might be related to stimulus differences in the two situations. Chromatic CSFs were also statistically significantly lower for the patients than for the controls, for both chromatic equiluminant stimuli: red-green (p<.005) and blue-yellow (p<.04 for all frequencies, except 2 cycles per degree (cpd), the highest spatial frequency tested) spatial gratings. We conclude that exposure to elemental mercury vapour is associated with profound and lasting losses in achromatic and chromatic visual functions, affecting the magno-, parvo- and koniocellular visual pathways.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...