Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 80
Filtrar
3.
J Arthroplasty ; 38(11): 2311-2315.e1, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37279843

RESUMO

BACKGROUND: Diabetes mellitus (DM) and obesity are associated with total knee arthroplasty (TKA) complications. Semaglutide, a medication for DM and weight loss, can potentially affect TKA outcomes. This study investigated whether semaglutide use during TKA demonstrates fewer: (1) medical complications; (2) implant-related complications; (3) readmissions; and (4) costs. METHODS: A retrospective query was performed using a National database to 2021. Patients undergoing TKA for osteoarthritis with DM and semaglutide use were successfully propensity score-matched to controls semaglutide = 7,051; control = 34,524. Outcomes included 90-day postoperative medical complications, 2-year implant-related complications, 90-day readmissions, in-hospital lengths of stay, and costs. Multivariate logistical regressions calculated odds ratios (ORs), 95% confidence intervals, and P values (P < .003 as significance threshold after Bonferroni correction). RESULTS: Semaglutide cohorts had higher incidence and odds of myocardial infarction (1.0 versus 0.7%; OR 1.49; P = .003), acute kidney injury (4.9 versus 3.9%; OR 1.28; P < .001), pneumonia (2.8 versus 1.7%; OR 1.67; P < .001), and hypoglycemic events (1.9 versus 1.2%; OR 1.55; P < .001), but lower odds of sepsis (0 versus 0.4%; OR 0.23; P < .001). Semaglutide cohorts also had lower odds of prosthetic joint infections (2.1 versus 3.0%; OR 0.70; P < .001) and readmission (7.0 versus 9.4%; OR 0.71; P < .001), and trended toward lower odds of revisions (4.0 versus 4.5%; OR 0.86; P = .02) and 90-day costs ($15,291.66 versus $16,798.46; P = .012). CONCLUSION: Semaglutide use during TKA decreased risk for sepsis, prosthetic joint infections, and readmissions, but also increased risk for myocardial infarction, acute kidney injury, pneumonia, and hypoglycemic events.


Assuntos
Injúria Renal Aguda , Artrite Infecciosa , Artroplastia do Joelho , Infarto do Miocárdio , Pneumonia , Sepse , Humanos , Artroplastia do Joelho/efeitos adversos , Estudos Retrospectivos , Fatores de Risco , Tempo de Internação , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Artrite Infecciosa/etiologia , Pneumonia/complicações , Sepse/complicações , Hipoglicemiantes , Injúria Renal Aguda/epidemiologia , Injúria Renal Aguda/etiologia , Injúria Renal Aguda/prevenção & controle , Infarto do Miocárdio/etiologia , Readmissão do Paciente
5.
Am J Sports Med ; 51(10): 2766-2773, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-35970181

RESUMO

Fibrosis is a common and debilitating pathological process that affects many organ systems and contributes to connective tissue disorders in orthopaedics. Tendons heal after acute and chronic injury through a process of fibrovascular scar tissue formation, and soft tissue joint capsules can be affected after traumatic joint injury, leading to arthrofibrosis. Although the precise underlying mechanisms are still being elucidated, fibrosis is thought to be a consequence of dysregulated immune and cytokine signaling that leads to myofibroblast activation and proliferation and subsequent excessive collagen deposition. Current treatments for connective tissue fibrosis include physical therapy and surgery, but there are no therapies that directly target the underlying cellular and molecular mechanisms of fibrosis. Many pharmacological agents have been used to successfully target fibrosis in other tissues and organ systems and thus are a promising treatment option to fill this gap. However, limited evidence is available to guide the use of these agents in musculoskeletal connective tissues. This article provides an overview of pharmacological therapies that have potential to treat connective tissue fibrosis in patients with musculoskeletal conditions, along with the current supporting evidence and future uses of each therapy.


Assuntos
Artropatias , Ortopedia , Humanos , Fibrose , Tecido Conjuntivo/patologia , Cicatriz/patologia
6.
Am J Sports Med ; 50(14): 3866-3874, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36305762

RESUMO

BACKGROUND: Previous studies have examined the transcriptomes and mechanical properties of whole tendons in different regions of the body. However, less is known about these characteristics within a single tendon. PURPOSE: To develop a regional transcriptomic atlas and evaluate the region-specific mechanical properties of Achilles tendons. STUDY DESIGN: Descriptive laboratory study. METHODS: Achilles tendons from 2-month-old male Sprague Dawley rats were used. Tendons were isolated and divided into proximal, middle, and distal thirds for RNA sequencing (n = 5). For mechanical testing, the Achilles muscle-tendon-calcaneus unit was mounted in a custom-designed materials testing system with the unit clamped over the musculotendinous junction (MTJ) and the calcaneus secured at 90° of dorsiflexion (n = 9). Tendons were stretched to 20 N at a constant speed of 0.0167 mm/s. Cross-sectional area, strain, stress, and Young modulus were determined in each tendon region. RESULTS: An open-access, interactive transcriptional atlas was generated that revealed distinct gene expression signatures in each tendon region. The proximal and distal regions had the largest differences in gene expression, with 2596 genes significantly differentially regulated at least 1.5-fold (q < .01). The proximal tendon displayed increased expression of genes resembling a tendon phenotype and increased expression of nerve cell markers. The distal region displayed increases in genes involved in extracellular matrix synthesis and remodeling, immune cell regulation, and a phenotype similar to cartilage and bone. There was a 3.72-fold increase in Young modulus from the proximal to middle region (P < .01) and an additional 1.34-fold increase from the middle to distal region (P = .027). CONCLUSION: Within a single tendon, there are region-specific transcriptomic signatures and mechanical properties, and there is likely a gradient in the biological and functional phenotype from the proximal origin at the MTJ to the distal insertion at the enthesis. CLINICAL RELEVANCE: These findings improve our understanding of the underlying biological heterogeneity of tendon tissue and will help inform the future targeted use of regenerative medicine and tissue engineering strategies for patients with tendon disorders.


Assuntos
Transcriptoma , Masculino , Ratos , Animais , Transcriptoma/genética , Ratos Sprague-Dawley
7.
Ther Adv Cardiovasc Dis ; 16: 17539447221119624, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36039865

RESUMO

BACKGROUND: Cardiac magnetic resonance (CMR) provides excellent temporal and spatial resolution, tissue characterization, and flow measurements. This enables major advantages when guiding cardiac invasive procedures compared with X-ray fluoroscopy or ultrasound guidance. However, clinical implementation is limited due to limited availability of technological advancements in magnetic resonance imaging (MRI) compatible equipment. A systematic review of the available literature on past and present applications of interventional MR and its technology readiness level (TRL) was performed, also suggesting future applications. METHODS: A structured literature search was performed using PubMed. Search terms were focused on interventional CMR, cardiac catheterization, and other cardiac invasive procedures. All search results were screened for relevance by language, title, and abstract. TRL was adjusted for use in this article, level 1 being in a hypothetical stage and level 9 being widespread clinical translation. The papers were categorized by the type of procedure and the TRL was estimated. RESULTS: Of 466 papers, 117 papers met the inclusion criteria. TRL was most frequently estimated at level 5 meaning only applicable to in vivo animal studies. Diagnostic right heart catheterization and cavotricuspid isthmus ablation had the highest TRL of 8, meaning proven feasibility and efficacy in a series of humans. CONCLUSION: This article shows that interventional CMR has a potential widespread application although clinical translation is at a modest level with TRL usually at 5. Future development should be directed toward availability of MR-compatible equipment and further improvement of the CMR techniques. This could lead to increased TRL of interventional CMR providing better treatment.


Assuntos
Imagem por Ressonância Magnética Intervencionista , Animais , Humanos , Imageamento por Ressonância Magnética , Imagem por Ressonância Magnética Intervencionista/métodos , Espectroscopia de Ressonância Magnética , Valor Preditivo dos Testes , Tecnologia
8.
Circ Arrhythm Electrophysiol ; 15(8): e010835, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35917465

RESUMO

BACKGROUND: Irreversible electroporation (IRE) ablation is generally performed with multielectrode catheters. Electrode-tissue contact is an important predictor for the success of pulmonary vein (PV) isolation; however, contact force is difficult to measure with multielectrode ablation catheters. In a preclinical study, we assessed the feasibility of a multielectrode impedance system (MEIS) as a predictor of long-term success of PV isolation. In addition, we present the first-in-human clinical experience with MEIS. METHODS: In 10 pigs, one PV was ablated based on impedance (MEIS group), and the other PV was solely based on local electrogram information (EP group). IRE ablations were performed at 200 J. After 3 months, recurrence of conduction was assessed. Subsequently, in 30 patients undergoing PV isolation with IRE, MEIS was evaluated and MEIS contact values were compared to local electrograms. RESULTS: In the porcine study, 43 IRE applications were delivered in 19 PVs. Acutely, no reconnections were observed in either group. After 3 months, 0 versus 3 (P=0.21) PVs showed conduction recurrence in the MEIS and EP groups, respectively. Results from the clinical study showed a significant linear relation was found between mean MEIS value and bipolar dV/dt (r2=0.49, P<0.001), with a slope of 20.6 mV/s per Ohm. CONCLUSIONS: Data from the animal study suggest that MEIS values predict effective IRE applications. For the long-term success of electrical PV isolation with circular IRE applications, no significant difference in efficacy was found between ablation based on the measurement of electrode interface impedance and ablation using the classical EP approach for determining electrode-tissue contact. Experiences of the first clinical use of MEIS were promising and serve as an important basis for future research.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Animais , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Eletroporação , Frequência Cardíaca , Humanos , Veias Pulmonares/cirurgia , Suínos , Resultado do Tratamento
10.
J Cardiovasc Electrophysiol ; 33(3): 360-367, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35018697

RESUMO

INTRODUCTION: Electroporation ablation creates deep and wide myocardial lesions. No data are available on time course and characteristics of acute lesion formation. METHODS: For the acute phase of myocardial lesion development, seven pigs were investigated. Single 200 J applications were delivered at four different epicardial right ventricular sites using a linear suction device, yielding a total of 28 lesions. Timing of applications was designed to yield lesions at seven time points: 0, 10, 20, 30, 40, 50, and 60 min, with four lesions per time point. After killing, lesion characteristics were histologically investigated. For the chronic phase of myocardial lesion development, tissue samples were used from previously conducted studies where tissue was obtained at 3 weeks and 3 months after electroporation ablation. RESULTS: Acute myocardial lesions induce a necrosis pattern with contraction band necrosis and interstitial edema, immediately present after electroporation ablation. No further histological changes such as hemorrhage or influx of inflammatory cells occurred in the first hour. After 3 weeks, the lesions consisted of sharply demarcated loose connective tissue that further developed to more fibrotic scar tissue after 3 months without additional changes. Within the scar tissue, arteries and nerves were unaffected. CONCLUSION: Electroporation ablation immediately induces contraction band necrosis and edema without additional tissue changes in the first hour. After 3 weeks, a sharply demarked scar has been developed that remains stable during follow-up of 3 months. This is highly relevant for clinical application of electroporation ablation in terms of the electrophysiological endpoint and waiting period after ablation.


Assuntos
Ablação por Cateter , Animais , Ablação por Cateter/efeitos adversos , Eletroporação , Ventrículos do Coração , Suínos
11.
J Cardiovasc Electrophysiol ; 33(3): 559-564, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35040534

RESUMO

BACKGROUND: Persistent phrenic nerve palsy (PNP) is an established complication of atrial fibrillation (AF) ablation, especially during cryoballoon and thoracoscopic ablation. Data on persistent PNP reversibility is limited because most patients recover <24 h. This study aims to investigate persistent PNP recovery, freedom of PNP-related symptoms after AF ablation and identify baseline variables associated with the occurrence and early PNP recovery in a large nationwide registry study. METHODS: In this study, we used data from the Netherlands Heart Registration, comprising data from 9549 catheter and thoracoscopic AF ablations performed in 2016 and 2017. PNP data was available of 7433 procedures, and additional follow-up data were collected for patients who developed persistent PNP. RESULTS: Overall, the mean age was 62 ± 10 years, and 67.7% were male. Fifty-four (0.7%) patients developed persistent PNP and follow-up was available in 44 (81.5%) patients. PNP incidence was 0.07%, 0.29%, 1.41%, and 1.25%, respectively for patients treated with conventional-RF, phased-RF, cryoballoon, and thoracoscopic ablation respectively. Seventy-one percent of the patients fully recovered, and 86% were free of PNP-related symptoms after a median follow-up of 203 (113-351) and 184 (82-359) days, respectively. Female sex, cryoballoon, and thoracoscopic ablation were associated with a higher risk to develop PNP. Patients with PNP recovering ≤180 days had a larger left atrium volume index than those with late or no recovery. CONCLUSION: After AF ablation, persistent PNP recovers in the majority of patients, and most are free of symptoms. Female patients and patients treated with cryoballoon or thoracoscopic ablation are more prone to develop PNP.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos/epidemiologia , Paralisia/etiologia , Nervo Frênico , Veias Pulmonares/cirurgia , Resultado do Tratamento
12.
Crit Care Med ; 50(4): 607-613, 2022 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-34636805

RESUMO

OBJECTIVES: The ratio between Pao2 and Fio2 is used as a marker for impaired oxygenation and acute respiratory distress syndrome classification. However, any discrepancy between Fio2 and o2 fraction in the alveolus affects the Pao2/Fio2 ratio. Correcting the Pao2/Fio2 ratios using the alveolar gas equation may result in an improved reflection of the pulmonary situation. This study investigates the difference between standard and corrected Pao2/Fio2 in magnitude, its correlation with the mortality of acute respiratory distress syndrome classification, and trends over time. DESIGN: A register and a retrospective study combined with the development of a mathematical model to determine the difference between standard and corrected Pao2/Fio2 ratio for various levels of Paco2 and atmospheric pressure. SETTING: ICU in a secondary hospital in The Netherlands. PATIENTS: Patients admitted to the ICU for pneumonia or acute respiratory distress syndrome. Register cohort: January 1, 2010, till March 1, 2020 (n = 1008). Retrospective cohort: March 1, 2020, till June 1, 2020 (n = 34). MEASUREMENTS AND MAIN RESULTS: The register was used to determine the 7-day ICU mortality per acute respiratory distress syndrome classification based on the standard and corrected Pao2/Fio2 ratio. The retrospective dataset correlated the Paco2 with Pao2/Fio2 ratio over time in patients with assumed stable oxygenation. The model demonstrated an increased difference between the standard and corrected Pao2/Fio2 ratios by a lower Fio2 and atmospheric pressure and higher Pao2 and Paco2. Reclassification of severe acute respiratory distress syndrome resulted in an increase in mortality from 28.1% for standard Pao2/Fio2 to 30.6% for corrected Pao2/Fio2 ratios. Acute Physiology and Chronic Health Evaluation scores correlated better with 7-day ICU-mortality when corrected Pao2/Fio2 ratio was used for classification. For patients with Fio2 less than 50% (n = 55), change in Paco2 correlated with change in Pao2/Fio2 ratio (r = -0.388; p = 0.003). INTERVENTIONS: A corrected Pao2/Fio2 ratio was calculated. CONCLUSIONS: Correcting the Pao2/Fio2 ratio for the alveolar gas equation predominantly affects patients with high ratios between Pao2 and Fio2 and Paco2 and at low atmospheric pressure. Using the corrected Pao2/Fio2 ratio for acute respiratory distress syndrome classification results in improved correlation with the 7-day ICU mortality and increases generalization among acute respiratory distress syndrome studies. The authors provide a free, web-based tool.


Assuntos
Hipercapnia , Síndrome do Desconforto Respiratório , Pressão Atmosférica , Humanos , Oxigênio , Síndrome do Desconforto Respiratório/terapia , Estudos Retrospectivos
13.
Clin Exp Hepatol ; 7(2): 241-247, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34295993

RESUMO

AIM OF THE STUDY: Non-alcoholic fatty liver disease (NAFLD), a globally prevailing chronic liver condition, refers to a spectrum of disease ranging from bland steatosis to steatohepatitis causing fibrosis without significant alcohol intake. Prominent risk factors (RFs) include obesity, type 2 diabetes mellitus, and dyslipidemia. Currently, no established hierarchy exists for the influence of metabolic RFs on NAFLD progression. This retrospective cohort study investigated and ranked the independent and combined effects of three major RFs on NAFLD progression. MATERIAL AND METHODS: 652 NAFLD patients with ≥ 1 RF were categorized by RF combination to examine yearly changes in RF severity with liver stiffness measurement (LSM) over five years. Body mass index (BMI), hemoglo- bin A1c (HbA1c), total cholesterol (TC), and LSM were reviewed. RESULTS: In patients with any single improving RF, decreases in BMI were associated with a yearly LSM change of -1.26 kPa, while decreases in HbA1c and TC were associated with a change of -0.51 kPa and -0.56 kPa, respectively. In patients with any single worsening RF, increases in BMI were correlated with an LSM change of +0.74 kPa and increases in HbA1c and TC were correlated with a change of +0.43 kPa and +0.16 kPa, respectively. Patients with three RFs had the greatest LSM changes for both improving (-3.68 kPa) and worsening (+3.19 kPa) groups. The strongest predictors for LSM change were BMI and HbA1c, with standardized ß coefficients of 0.236 and 0.226 (p < 0.001), while TC had the least influence [0.112 (p < 0.01), F(3,647) = 11.458, p < 0.001, R 2 = 0.155]. CONCLUSIONS: Obesity was the most prominent RF. Treatment of all three RFs over a five-year period presented a high likelihood of fibrosis stage regression for NAFLD patients.

14.
BMC Med Ethics ; 22(1): 73, 2021 06 17.
Artigo em Inglês | MEDLINE | ID: mdl-34139997

RESUMO

BACKGROUND: The COVID-19 pandemic has created ethical challenges for intensive care unit (ICU) professionals, potentially causing moral distress. This study explored the levels and causes of moral distress and the ethical climate in Dutch ICUs during COVID-19. METHODS: An extended version of the Measurement of Moral Distress for Healthcare Professionals (MMD-HP) and Ethical Decision Making Climate Questionnaire (EDMCQ) were online distributed among all 84 ICUs. Moral distress scores in nurses and intensivists were compared with the historical control group one year before COVID-19. RESULTS: Three hundred forty-five nurses (70.7%), 40 intensivists (8.2%), and 103 supporting staff (21.1%) completed the survey. Moral distress levels were higher for nurses than supporting staff. Moral distress levels in intensivists did not differ significantly from those of nurses and supporting staff. "Inadequate emotional support for patients and their families" was the highest-ranked cause of moral distress for all groups of professionals. Of all factors, all professions rated the ethical climate most positively regarding the culture of mutual respect,  ethical awareness and support. "Culture of not avoiding end-of-life-decisions" and "Self-reflective and empowering leadership" received the lowest mean scores. Moral distress scores during COVID-19 were significantly lower for ICU nurses (p < 0.001) and intensivists (p < 0.05) compared to one year prior. CONCLUSION: Levels and causes of moral distress vary between ICU professionals and differ from the historical control group. Targeted interventions that address moral distress during a crisis are desirable to improve the mental health and retention of ICU professionals and the quality of patient care.


Assuntos
COVID-19 , Atitude do Pessoal de Saúde , Cuidados Críticos , Humanos , Unidades de Terapia Intensiva , Princípios Morais , Pandemias , SARS-CoV-2 , Estresse Psicológico , Inquéritos e Questionários
15.
Biomed Eng Online ; 18(1): 75, 2019 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-31221146

RESUMO

BACKGROUND: Irreversible electroporation (IRE) using direct current (DC) is an effective method for the ablation of cardiac tissue. A major drawback of the use of DC-IRE, however, are two problems: requirement of general anesthesia due to severe muscle contractions and the formation of bubbles containing gaseous products from electrolysis. The use of high-frequency alternating current (HF-IRE) is expected to solve both problems, because HF-IRE produces little to no muscle spasms and does not cause electrolysis. METHODS: In the present study, we introduce a novel asymmetric, high-frequency (aHF) waveform for HF-IRE and present the results of a first, small, animal study to test its efficacy. RESULTS: The data of the experiments suggest that the aHF waveform creates significantly deeper lesions than a symmetric HF waveform of the same energy and frequency (p = 0.003). CONCLUSION: We therefore conclude that the use of the aHF enhances the feasibility of the HF-IRE method.


Assuntos
Técnicas de Ablação/métodos , Arritmias Cardíacas/terapia , Eletroporação/métodos , Animais , Arritmias Cardíacas/fisiopatologia , Condutividade Elétrica , Contração Miocárdica , Suínos
16.
Europace ; 20(1): 149-156, 2018 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-28064250

RESUMO

Aims: With multi-electrode catheters, measuring contact force (CF) on each electrode is technically challenging. Present electrical methods, like the electrical coupling index (ECI) may yield false positive values in pulmonary veins. We developed a novel method that measures electrode-interface resistance (IR) by applying a very local electrical field between neighbouring catheter electrodes while measuring voltage between each catheter electrode and a skin patch. The aim of this study was to evaluate the new IR method to measure electrode-tissue contact. Methods and results: In vitro, effects of remote high-impedance structures were studied. In addition, both ECI and IR were directly compared with true electrode-tissue CF. In five pigs, the influence of high-impedance pulmonary tissue on ECI and IR was investigated while navigating the free floating catheter into the caval veins. Inside the left atrium (LA), IR was directly compared with CF. Finally, multi-electrode IR measurements in the LA and inferior pulmonary vein (IPV) were compared. In vitro, IR is much less affected by remote high-impedance structures than ECI (3% vs. 32%). Both IR and ECI strongly relate to electrode-tissue CF (r2 = 0.84). In vivo, and in contrast to ECI, IR was not affected by nearby pulmonary tissue. Inside the LA, a strong relation between IR and CF was found. This finding was confirmed by simultaneous multi-electrode measurements in LA and IPV. Conclusion: Data of the present study suggest that electrode-tissue contact affects the IR while being highly insensitive to remote structures. This method facilitates electrode-tissue contact measurements with circular multi-electrode ablation catheters.


Assuntos
Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Átrios do Coração/cirurgia , Veias Pulmonares/cirurgia , Animais , Impedância Elétrica , Desenho de Equipamento , Teste de Materiais , Modelos Animais , Sus scrofa
17.
Europace ; 18(9): 1335-42, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26838694

RESUMO

AIMS: Pulmonary vein antrum isolation (PVAI) is the cornerstone of atrial fibrillation (AF) ablation. There is an ongoing discussion on whether and when to add substrate modification to PVAI. This study evaluates (1) long-term efficacy of PVAI as a primary ablation strategy in all patients independently from AF type and (2) predictors of arrhythmia recurrence. METHODS AND RESULTS: A total of 509 consecutive patients (mean age 57 years, 38.9% non-paroxysmal AF) with AF underwent PVAI. In redo procedures, ablation was restricted to re-pulmonary vein (PV) isolation in case of PV reconnection. If the PVs were found to be isolated, substrate modification was performed. In total, 774 procedures were performed. Mean follow-up duration after the first and last ablation was, respectively, 66 ± 23 and 55 ± 25 months. A single PVAI was sufficient in restoring and maintaining long-term sinus rhythm in 41.3% (n = 210) of patients. Multiple procedures (mean 1.5) with re-PV isolation increased long-term success to 58.3% (n = 297). Additional substrate modification (n = 70) increased success to 62.5% (n = 318). After the last ablation, 87.5% of patients experienced success or significant clinical improvement on or off antiarrhythmic drugs. The incidence of left-sided atrial flutter or atrial tachycardia was 5% after PVAI and increased to 32% after additional substrate modification. Independent predictors for arrhythmia recurrence after the last ablation were non-paroxysmal AF, female sex, body mass index, hypertension, and AF duration. CONCLUSION: Five-year freedom of atrial tachyarrhythmia could be achieved by PVAI as primary ablation strategy in 58.3% of patients. Additional substrate modification only moderately increased overall success.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Estudos de Coortes , Intervalo Livre de Doença , Feminino , Frequência Cardíaca , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Países Baixos , Modelos de Riscos Proporcionais , Veias Pulmonares/fisiopatologia , Recidiva , Reoperação , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
18.
J Interv Card Electrophysiol ; 44(3): 227-34, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26369330

RESUMO

BACKGROUND: With the advent of magnetic resonance imaging (MRI) conditional pacemaker systems, the possibility of performing MRI in pacemaker patients has been introduced. Besides for the detailed evaluation of atrial and ventricular volumes and function, MRI can be used in combination with body surface potential mapping (BSPM) in a non-invasive inverse potential mapping (IPM) strategy. In non-invasive IPM, epicardial potentials are reconstructed from recorded body surface potentials (BSP). In order to investigate whether an IPM method with a limited number of electrodes could be used for the purpose of non-invasive focus localization, it was applied in patients with implanted pacing devices. Ventricular paced beats were used to simulate ventricular ectopic foci. METHODS: Ten patients with an MRI-conditional pacemaker system and a structurally normal heart were studied. Patient-specific 3D thorax volume models were reconstructed from the MRI images. BSP were recorded during ventricular pacing. Epicardial potentials were inversely calculated from the BSP. The site of epicardial breakthrough was compared to the position of the ventricular lead tip on MRI and the distance between these points was determined. RESULTS: For all patients, the site of earliest epicardial depolarization could be identified. When the tip of the pacing lead was implanted in vicinity to the epicardium, i.e. right ventricular (RV) apex or RV outflow tract, the distance between lead tip position and epicardial breakthrough was 6.0 ± 1.9 mm. CONCLUSIONS: In conclusion, the combined MRI and IPM method is clinically applicable and can identify sites of earliest depolarization with a clinically useful accuracy.


Assuntos
Mapeamento Potencial de Superfície Corporal/instrumentação , Sistema de Condução Cardíaco/fisiopatologia , Imageamento por Ressonância Magnética/instrumentação , Marca-Passo Artificial , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/fisiopatologia , Mapeamento Potencial de Superfície Corporal/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Ventrículos do Coração/fisiopatologia , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Imagem Multimodal/instrumentação , Imagem Multimodal/métodos , Pericárdio/fisiopatologia , Projetos Piloto , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
19.
Heart Rhythm ; 12(8): 1838-44, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25998897

RESUMO

BACKGROUND: Circular electroporation ablation is a novel ablation modality for electrical pulmonary vein isolation. With a single 200-J application, deep circular myocardial lesions can be created. However, the acute and chronic effects of this energy source on phrenic nerve (PN) function are unknown. OBJECTIVE: The purpose of this study was to analyze nerve vulnerability to electroporation ablation in a porcine model. METHODS: In 20 animals (60-75 kg), the course of the right PN was pace-mapped inside the superior caval vein (SCV). Thereafter, a single 200-J circular electroporation ablation was performed via a multipolar circular catheter in firm contact with the inner SCV wall. RESULTS: In 19 of 20 animals, the PN could be captured along an estimated 6-8 cm trajectory above the right atrial contour. Directly after the application, the PN could be captured above the ablation level in 17 of 19 animals and after maximally 30 minutes in all animals. Fifteen animals were restudied after 3-13 weeks, and PN functionality was unaffected in all. Histological analysis in 5 animals in which the application had been delivered in the muscular sleeve just above the right atrium showed a transmural circular lesion. However, no lesion was found in the other animals in which the application had been delivered in the fibrous section more cranial in the SCV. CONCLUSIONS: Electroporation ablation at an energy level that may create deep myocardial lesions may spare the targeted right PN. These animal data suggest that electroporation may be a safe ablation modality near the right PN.


Assuntos
Ablação por Cateter/métodos , Eletroporação/métodos , Átrios do Coração/cirurgia , Traumatismos Cardíacos/complicações , Nervo Frênico/lesões , Animais , Ablação por Cateter/efeitos adversos , Átrios do Coração/fisiopatologia , Traumatismos Cardíacos/etiologia , Nervo Frênico/fisiologia , Suínos
20.
Ann Noninvasive Electrocardiol ; 20(2): 132-9, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25041476

RESUMO

BACKGROUND: In noninvasive imaging of cardiac excitation, the use of body surface potentials (BSP) rather than body volume potentials (BVP) has been favored due to enhanced computational efficiency and reduced modeling effort. Nowadays, increased computational power and the availability of open source software enable the calculation of BVP for clinical purposes. In order to illustrate the possible advantages of this approach, the explanatory power of BVP is investigated using a rectangular tank filled with an electrolytic conductor and a patient specific three dimensional model. METHODS: MRI images of the tank and of a patient were obtained in three orthogonal directions using a turbo spin echo MRI sequence. MRI images were segmented in three dimensional using custom written software. Gmsh software was used for mesh generation. BVP were computed using a transfer matrix and FEniCS software. RESULTS: The solution for 240,000 nodes, corresponding to a resolution of 5 mm throughout the thorax volume, was computed in 3 minutes. The tank experiment revealed that an increased electrode surface renders the position of the 4 V equipotential plane insensitive to mesh cell size and reduces simulated deviations. In the patient-specific model, the impact of assigning a different conductivity to lung tissue on the distribution of volume potentials could be visualized. CONCLUSION: Generation of high quality volume meshes and computation of BVP with a resolution of 5 mm is feasible using generally available software and hardware. Estimation of BVP may lead to an improved understanding of the genesis of BSP and sources of local inaccuracies.


Assuntos
Eletrocardiografia , Coração/fisiologia , Imageamento por Ressonância Magnética , Modelos Cardiovasculares , Humanos , Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...