Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Neth Heart J ; 28(5): 229-239, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31981094

RESUMO

The current paper presents a position statement of the Dutch Working Group of Transcatheter Heart Valve Interventions that describes which patients with aortic stenosis should be considered for transcatheter aortic valve implantation and how this treatment proposal/decision should be made. Given the complexity of the disease and the assessment of its severity, in particular in combination with the continuous emergence of new clinical insights and evidence from physiological and randomised clinical studies plus the introduction of novel innovative treatment modalities, the gatekeeper of the treatment proposal/decision and, thus, of qualification for cost reimbursement is the heart team, which consists of dedicated professionals working in specialised centres.

2.
Int J Cardiol ; 225: 218-225, 2016 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-27732925

RESUMO

AIMS: Pulmonary hypertension (PH) is associated with mortality after transcatheter aortic valve implantation (TAVI). However, diagnosis based on tricuspid regurgitant velocity (TRV) is often inaccurate and unreliable. The updated PH guidelines introduced a PH probability grading implementing additional PH signs on transthoracic echocardiography (TTE), from which we aimed to analyse its effects on clinical outcomes in patients undergoing TAVI. METHODS AND RESULTS: We included 591 consecutive patients (mean age 80.2±8.4years, 58.0% female, mean STS risk score 6.2±3.8%) undergoing TAVI. Patients were divided into "low" (n=270; TRV ≤2.8m/s without additional PH signs), "intermediate" (n=131; TRV ≤2.8m/s with additional PH signs, or TRV 2.9-3.4m/s without additional PH signs), and "high" PH probability (n=190; TRV 2.9-3.4m/s with additional PH signs, or TRV >3.4m/s). The overall 30-day and 2-year mortality rates were 10.2% and 33.8%, respectively. "High" PH probability was an independent predictor of mortality at 30days (HR 3.68, 95% CI 2.03 to 6.67, p<0.01) and 2years (HR 2.19, 95% CI 1.57 to 3.04, p<0.01), compared to "low" PH probability. The "intermediate" group did not show an increased risk. The presence of additional PH signs resulted in a significantly higher mortality at 30days (19.6% vs. 5.1%, p<0.01) and two years (54.2% vs. 22.5%, p<0.01). CONCLUSIONS: The updated echocardiographic PH probability model incorporating additional PH signs independently predicts early and late mortality after TAVI. Additional PH signs are of great value in assessing one's risks since its presence is strongly associated with early and late mortality.


Assuntos
Ecocardiografia/tendências , Hipertensão Pulmonar/diagnóstico por imagem , Hipertensão Pulmonar/mortalidade , Substituição da Valva Aórtica Transcateter/mortalidade , Substituição da Valva Aórtica Transcateter/tendências , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/cirurgia , Feminino , Seguimentos , Humanos , Hipertensão Pulmonar/cirurgia , Masculino , Mortalidade/tendências , Estudos Prospectivos , Estudos Retrospectivos , Resultado do Tratamento
3.
Neth Heart J ; 24(7-8): 475-80, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27189214

RESUMO

BACKGROUND: Surgical risk scores are used to identify high-risk patients for surgical mitral valve repair. There is no scoring system to estimate the mortality risk for patients undergoing percutaneous treatment. The aim of this analysis is to evaluate the predictive value of the EuroSCOREs and the Society of Thoracic Surgeons Predicted Risk of Mortality Score (STS) for periprocedural mortality in percutaneous edge-to-edge mitral valve repair. METHODS: From 2009 to 2013, 136 high-risk patients were included who underwent 143 procedures. Observed periprocedural mortality was compared with predicted mortality using the logistic EuroSCORE, EuroSCORE II and STS. The predictive value was analysed by receiver operating characteristic curves for each score. RESULTS: Observed periprocedural mortality was 3.5 %. The predicted surgical mortality risk was: 23.1 ± 15.7 % for the logistic EuroSCORE, 9.6 ± 7.7 % for the EuroSCORE II and 13.2 ± 8.2 % for the STS. The predictive value estimated by the area under the curve was: 0.55, 0.54 and 0.65 for the logistic EuroSCORE, EuroSCORE II and STS respectively. Severe pulmonary hypertension and acute procedural success were significant predictive parameters in univariate analysis. CONCLUSION: Contemporary surgical scores do not adequately predict periprocedural mortality for high-risk patients undergoing edge-to-edge mitral valve repair, but they can be used to help decision-making in the selection process for this procedure.

4.
Neth Heart J ; 23(1): 35-41, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25326104

RESUMO

AIMS: Since the introduction of transcatheter aortic valve implantation (TAVI), newer generation and novel devices such as the retrievable JenaValve™ have been developed. We evaluated the procedural and 6-month results of our first experience with implantation of the JenaValve™. METHODS AND RESULTS: From June 2012 to December 2013, 24 consecutive patients (mean age 80 ± 7 years, 42 % male) underwent an elective transapical TAVI with the JenaValve™. Device success was 88 %. The mortality rate was 4 % at 30 days and 31 % at 6 months. TAVI reduced the mean transvalvular gradient (44.2 ± 11.1 mmHg vs. 12.3 ± 4.3 mmHg, p < 0.001) and increased the mean aortic valve area (0.8 3 ± 0.23 to 1.70 ± 0.44 cm(2)). A mild paravalvular leakage (PVL) occurred in 4 patients (18 %) and a moderate PVL in 1 patient (4 %). Mean New York Heart Association Functional Class improved from 2.9 ± 0.5 to 2.0 ± 0.8 at 30 days. CONCLUSION: TAVI using the JenaValve™ prosthesis seems adequate and safe in this first experience cohort.

5.
Perfusion ; 29(3): 249-59, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24214029

RESUMO

INTRODUCTION: Cardiopulmonary bypass surgery is associated with a systemic inflammatory response through the interaction of air, blood and synthetic components in the bypass system and the physical trauma of surgery. An alternative cardiopulmonary bypass system, minimal extracorporeal circulation (MECC), has shown promising results in terms of reducing the inflammatory response. We hypothesized that this system may reduce pathological excessive scarring. To study this assumption, the effects of MECC and the effects of conventional extracorporeal circulation (CECC) with dexamethasone on skin scarring were compared in a standardized wound-healing model. METHODS AND RESULTS: Pre-sternal scars were evaluated prospectively at four and 12 months postoperatively. The height and width of the scars were measured, using a slide caliper and sonography. The scars were scored using the validated Patient and Observer Scar Assessment Scale. Additional risk factors for hypertrophic scar formation were identified by means of a questionnaire. During surgery, MECC was used in 45 patients and CECC/dexamethasone in 42 patients. Four months postoperatively, 22 patients of the MECC group (49%) and 18 patients in the CECC/dexamethasone group (43%) had developed hypertrophic scars. Twelve months postoperatively, the hypertrophic scars in four patients of the MECC group and in two patients of the CECC/dexamethasone group had become normotrophic. In 18 patients of the MECC group (38%) and 16 patients of the CECC group (41%) the scars remained hypertrophic at 12 months. These differences between the two groups were not statistically significant. CONCLUSION: MECC does not reduce hypertrophic scar formation compared with CECC with dexamethasone, but its use is more beneficial than the use of CECC/dexamethasone because of the circulatory and immunological advantages and because treatment with dexamethasone can be omitted.


Assuntos
Anti-Inflamatórios/administração & dosagem , Cicatriz Hipertrófica/etiologia , Dexametasona/administração & dosagem , Circulação Extracorpórea/efeitos adversos , Cicatrização/efeitos dos fármacos , Idoso , Anti-Inflamatórios/efeitos adversos , Cicatriz Hipertrófica/patologia , Cicatriz Hipertrófica/prevenção & controle , Dexametasona/efeitos adversos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade
7.
Int J Artif Organs ; 28(1): 35-43, 2005 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15742308

RESUMO

BACKGROUND: Current pulsatile pumps for cardiopulmonary bypass (CPB) are far from satisfactory because of the poor pulsatility. This study was undertaken to examine the efficiency of a novel pulsatile catheter pump on pulsatility and its effect on abdominal organ perfusion during CPB. METHODS: Twelve pigs weighing 89+/-11 kg were randomly divided into a pulsatile group (n=6) and a non-pulsatile group (n=6). All animals had a CPB for 120 min, aorta clamped for 60 min, temperature down to 32 degrees C, and a perfusion flow of 60 ml/kg/min. In the pulsatile group, a 21 Fr intra-aortic pulsatile catheter, which was connected to a 40 mL membrane pump, was placed in the descending aorta and activated by a balloon pump driver during the first 90 minutes of CPB until aortic declamping. Hemodynamics, organ blood flow, body metabolism, and blood trauma were studied during experiments. RESULTS: Compared with the non-pulsatile group during CPB, the pulsatile group had a higher systolic blood pressure (p<0.01), higher mean arterial pressure (p<0.05), and higher blood flow to the superior mesenteric artery (p<0.05). The hemodynamic energy, indicated by the energy equivalent pressure (EEP) was higher in the gastrointestinal tract and kidney in the pulsatile group (p<0.01, p<0.01). Abdominal organ perfusion status, as indicated by SvO 2 in the inferior vena cava, was higher in the pulsatile group (p<0.05) 30 min after cessation of CPB. Hemolysis indicated by release of free hemoglobin during CPB was similar in the two groups. CONCLUSION: Applying the pulsatile catheter pump in the descending aorta is effective in supplying the pulsatile flow to the abdominal organs and results in improved abdominal organ perfusion during the ischemic phase of CPB.


Assuntos
Abdome , Ponte Cardiopulmonar/instrumentação , Fluxo Pulsátil/fisiologia , Vísceras/irrigação sanguínea , Animais , Aorta Torácica/fisiologia , Contagem de Células Sanguíneas , Pressão Sanguínea/fisiologia , Cateterismo/instrumentação , Trato Gastrointestinal/irrigação sanguínea , Hemoglobinas/análise , Hemólise/fisiologia , Rim/irrigação sanguínea , Lactatos/sangue , Artéria Mesentérica Superior/fisiologia , Oxigênio/sangue , Distribuição Aleatória , Fluxo Sanguíneo Regional/fisiologia , Suínos , Fatores de Tempo , Veia Cava Inferior/fisiologia
8.
Thorac Cardiovasc Surg ; 50(2): 108-9, 2002 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11981715

RESUMO

Intra-abdominal migration of a generator from an epicardial pacemaker system is a rare but potentially life-threatening complication. We report on a case of a 2-year-old child in whom the generator silently migrated from the sheath of the rectus abdominis muscle in the upper abdominal wall down into the peritoneal cavity. We advise that if there is any evidence of intra-abdominal migration, the generator should be properly repositioned without delay.


Assuntos
Remoção de Dispositivo/métodos , Marca-Passo Artificial/efeitos adversos , Falha de Prótese , Pré-Escolar , Feminino , Bloqueio Cardíaco/terapia , Humanos , Resultado do Tratamento
9.
J Gen Microbiol ; 134(3): 599-604, 1988 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-3053974

RESUMO

The subcellular location of LamB-LacZ hybrid proteins in the Escherichia coli K12 strains pop3234 and pop3299 was investigated by immunocytochemical detection and protease-accessibility experiments. Induction of the synthesis of the hybrid proteins resulted in the appearance of membrane-like structures within the cytoplasm of the cells. Labelling of ultrathin cryosections of the cells with anti-beta-galactosidase or anti-LamB protein serum and protein-A-gold complexes revealed that the hybrid proteins were associated with these membrane-like structures or accumulated within the cytoplasm. Protease-accessibility experiments confirmed this localization. Moreover, when low quantities of hybrid proteins were produced, i.e. in uninduced pop3234 cells or in induced pop3299 cells, the hybrid proteins were accessible to trypsin from the periplasmic side of the inner membrane, leaving protected fragments with an apparent Mr of 83,000. Apparently, these hybrid proteins are partly translocated through the inner membrane, resulting in membrane-spanning forms of the proteins.


Assuntos
Proteínas de Bactérias/metabolismo , Escherichia coli/metabolismo , Membranas Intracelulares/metabolismo , Proteínas da Membrana Bacteriana Externa/análise , Imuno-Histoquímica , Peptídeo Hidrolases/metabolismo , Multimerização Proteica , Radioimunoensaio
10.
FEBS Lett ; 221(2): 226-30, 1987 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-3114001

RESUMO

Protease accessibility experiments were employed to localize a PhoE-LacZ hybrid protein, encompassing a large N-terminal fragment of the outer membrane PhoE protein of E. coli, fused to beta-galactosidase, at the subcellular level. In previous studies, this protein was shown to co-fractionate with the outer membrane, whereas immunocytochemical methods suggested a cytoplasmic location. The present results confirm the latter localization. Moreover, it appears that a minor amount of hybrid protein spans the inner membrane, with the PhoE moiety in the periplasm and the beta-galactosidase moiety in the cytoplasm. These membrane-spanning proteins might be responsible for the lethal jamming of the export machinery, observed upon induction of synthesis of the protein.


Assuntos
Proteínas da Membrana Bacteriana Externa/análise , Escherichia coli/análise , Galactosidases/análise , Proteínas Recombinantes de Fusão/análise , Proteínas Recombinantes/análise , beta-Galactosidase/análise , Ácido Edético/farmacologia , Tripsina/farmacologia
11.
Immunogenetics ; 23(5): 341-7, 1986.
Artigo em Inglês | MEDLINE | ID: mdl-3458670

RESUMO

The polymorphism of feline MHC antigens was examined using biochemical methods. The following observations were made: (1) feline class I and II antigens are polymorphic. Their biochemical features were established using rabbit and mouse reagents directed against human MHC products; they resemble those observed for other mammalian species; (2) the expression of class II antigens in unstimulated cat peripheral blood lymphocytes (PBLs) appears to be unusually high. Cat PBLs express far more class II than class I antigens, whereas in human Epstein-Barr virus-transformed lines, which are known to express relatively large amounts of class II antigens, the situation is reversed.


Assuntos
Gatos/imunologia , Antígenos de Histocompatibilidade Classe II/imunologia , Antígenos de Histocompatibilidade/imunologia , Linfócitos/imunologia , Complexo Principal de Histocompatibilidade , Animais , Anticorpos Monoclonais , Detergentes , Ponto Isoelétrico , Proteínas de Membrana/análise , Peso Molecular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...