Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
1.
Colomb. med ; 54(3)sept. 2023.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1534292

RESUMO

Background: The use of instruments in clinical practice with measurement properties tested is highly recommended, in order to provide adequate assessment and measurement of outcomes. Objective: To calculate the minimum clinically important difference (MCID) and responsiveness of the Perme Intensive Care Unit Mobility Score (Perme Score). Methods: This retrospective, multicentric study investigated the clinimetric properties of MCID, estimated by constructing the Receiver Operating Characteristic (ROC). Maximizing sensitivity and specificity by Youden's, the ROC curve calibration was performed by the Hosmer and Lemeshow goodness-of-fit test. Additionally, we established the responsiveness, floor and ceiling effects, internal consistency, and predictive validity of the Perme Score. Results: A total of 1.200 adult patients records from four mixed general intensive care units (ICUs) were included. To analyze which difference clinically reflects a relevant evolution we calculated the area under the curve (AUC) of 0.96 (95% CI: 0.95-0.98), and the optimal cut-off value of 7.0 points was established. No substantial floor (8.8%) or ceiling effects (4.9%) were observed at ICU discharge. However, a moderate floor effect was observed at ICU admission (19.3%), in contrast to a very low incidence of ceiling effect (0.6%). The Perme Score at ICU admission was associated with hospital mortality, OR 0.86 (95% CI: 0.82-0.91), and the predictive validity for ICU stay presented a mean ratio of 0.97 (95% CI: 0.96-0.98). Conclusion: Our findings support the establishment of the minimum clinically important difference and responsiveness of the Perme Score as a measure of mobility status in the ICU.


Antecedentes: Se recomienda encarecidamente el uso de instrumentos en la práctica clínica con propiedades de medición probadas, con el fin de proporcionar una evaluación y medición adecuada de los resultados. Objetivo: Calcular la diferencia mínima clínicamente importante (MCID) y la capacidad de respuesta de la puntuación de movilidad de la unidad de cuidados intensivos de Perme (Perme Score). Métodos: Este estudio multicéntrico retrospectivo investigó las propiedades clinimétricas de MCID, estimadas mediante la construcción de la característica operativa del receptor (ROC). Maximizando la sensibilidad y especificidad mediante la prueba de Youden, la calibración de la curva ROC se realizó mediante la prueba de bondad de ajuste de Hosmer y Lemeshow. Además, establecimos la capacidad de respuesta, los efectos suelo y techo, la consistencia interna y la validez predictiva del Perme Score. Resultados: Se incluyeron un total de 1,200 registros de pacientes adultos de cuatro unidades de cuidados intensivos (UCI) generales mixtas. Para analizar qué diferencia refleja clínicamente una evolución relevante calculamos el área bajo la curva (AUC) de 0.96 (95% CI: 0.95-0.98); y se estableció el valor de corte óptimo de 7.0 puntos. No se observaron efectos suelo (8.8%) o techo (4.9%) sustanciales al alta de la UCI. Sin embargo, se observó un efecto suelo moderado al ingreso en la UCI (19.3%), en contraste con una incidencia muy baja del efecto techo (0.6%). El Perme Score al ingreso en UCI se asoció con la mortalidad hospitalaria, OR 0.86 (95% CI: 0.82-0.91), y la validez predictiva de estancia en UCI presentó una relación media de 0.97 (95% CI: 0.96-0.98). Conclusiones: Nuestros hallazgos respaldan el establecimiento de la diferencia mínima clínicamente importante y la capacidad de respuesta de el Perme Score como medida del estado de movilidad en la UCI.

2.
Rev. esp. med. nucl. imagen mol. (Ed. impr.) ; 41(6): 368-372, nov. - dic. 2022. ilus, graf
Artigo em Espanhol | IBECS | ID: ibc-212062

RESUMO

Introducción Entre los objetivos en los tratamientos con esferas marcadas con ytrio-90 figura demostrar que se consigue la dosis tumoricida y que se evitan dosis hepatotóxicas, así como que no existe deposición extrahepática. Material y métodos Utilizamos diferentes cantidades de ytrio y un maniquí NEMA NU2-2007 para comprobar si el tomógrafo mantiene una respuesta que permita hacer cálculos dosimétricos reales. Resultados El tomógrafo Gemini responde de manera lineal en un rango amplio de actividades con una R2=0,9983. Conclusión La capacidad de detección del equipo PET nos permite realizar estudios de cuerpo estándar con finalidad dosimétrica con tiempos de 5min por BED, que además hacen posible verificar la ausencia de deposición extrahepática de cantidades significativas de esferas de ytrio-90 (AU)


Introduction Among the objectives in treatments with yttrium-90 spheres is to demonstrate that the tumoricidal dose is achieved and that hepatotoxic doses are avoided, as well as that there is no extrahepatic deposition. Material and methods We use different amounts of yttrium-90 resin micro-spheres and a NEMA NU2-2007 phantom to check if the scanner maintains a response that allows real dosimetric calculations. Results The Gemini tomograph responds linearly in a wide range of activities with R2=0.9983. Conclusion The detection capacity of the PET equipment allows us to carry out standard body studies with dosimetric purposes with times of five minutes per BED. It also make possible to verify the absence of extrahepatic deposition of significant amounts of yttrium 90 spheres (AU)


Assuntos
Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Radioisótopos de Ítrio/uso terapêutico , Radiometria , Calibragem
3.
Enfermeria (Montev.) ; 11(2)dic. 2022.
Artigo em Espanhol | LILACS-Express | LILACS, BDENF - Enfermagem | ID: biblio-1404693

RESUMO

Resumen: Introducción: El láser de baja potencia es una técnica utilizada en varias áreas de la salud: fisioterapia, odontología, otorrinolaringología y dermatología, entre otras. Para lograr los efectos terapéuticos la dosificación es fundamental y depende de los niveles de energía emitidos por los equipos. Objetivo: Conocer el estado de calibración y mantenimiento de los equipos de laserterapia de baja potencia, en servicios de fisioterapia u homólogos de instituciones de Montevideo, Uruguay. Método: Se realizó un estudio descriptivo, transversal en servicios de fisioterapia de Montevideo. Se analizaron 20 equipos de láser de baja potencia. Resultados: 7 de los aparatos evaluados se mantuvieron dentro de los límites adecuados de emisión. De los 13 láser fuera de los límites para entregar una emisión adecuada, 6 tenían un desajuste leve, 1 presentaba un desajuste moderado y 6 presentaban un desajuste severo con dosis nulas o que no generaban emisión. Del total de equipos evaluados solo 6 habían realizado una calibración previa y solo 2 de estos se encontraban dentro de los tiempos recomendados. Conclusión: Se observó un gran número de equipos de láser de baja potencia con desajustes en su emisión. En la mayoría de los casos no se lleva un correcto mantenimiento de los aparatos de láser de baja potencia. Se entiende relevante que los equipos sean calibrados para poder ofrecer una terapéutica segura y efectiva a los usuarios.


Resumo: Introdução: O laser de baixa potência é uma técnica utilizada em diversas áreas da saúde: fisioterapia, odontologia, otorrinolaringologia, dermatologia, dentre outras. Para obter efeitos terapêuticos, a dosagem é essencial e depende dos níveis de energia emitidos pelo equipamento. Objetivo: conhecer o estado de calibração e manutenção de equipamentos de laserterapia de baixa potência, em serviços de fisioterapia ou congêneres de instituições em Montevideu - Uruguai. Método: estudo descritivo, transversal, realizado em serviços de fisioterapia em Montevideo, Uruguai. 20 equipamentos de laser de baixa potência foram analisados. Resultados: 7 dos aparelhos avaliados permaneceram dentro dos limites de emissão adequados. Dos 13 lasers fora dos limites para entregar a emissão adequada, 6 tiveram uma leve incompatibilidade, 1 teve uma incompatibilidade moderada e 6 apresentaram uma incompatibilidade grave. Do total de equipamentos avaliados, apenas 6 haviam realizado uma calibragem prévia e apenas 2 destes estavam dentro do prazo recomendado (1 ano). Conclusão: observou-se um grande número de equipamentos de laser de baixa potência com desequilíbrios em sua emissão. Na maioria dos casos, os dispositivos a laser de baixa potência não recebem manutenção adequada. Acredita-se importante que os equipamentos sejam calibrados para oferecer uma terapia segura e eficaz aos usuários.


Abstract: Introduction: The low-power laser is a technique used in several areas of health: physiotherapy, dentistry, otorhinolaryngology and dermatology, among others. To achieve therapeutic effects, the dosage is essential and depends on the energy levels emitted by the device. Objective: To know the status of calibration and maintenance of low power laser therapy devices, in physiotherapy services or counterparts of institutions in Montevideo - Uruguay. Method: A descriptive, cross-sectional study was conducted in physiotherapy services in Montevideo, Uruguay. 20 low-power laser devices were analyzed. Results: 7 of the devices evaluated remained within the appropriate emission limits. Of the 13 lasers outside the limits to deliver adequate emission, 6 had a slight mismatch, 1 had a moderate mismatch, and 6 presented a severe mismatch. Among the total devices evaluated, only 6 had performed a previous calibration and only 2 of these were within the recommended times frames. Conclusion: A large number of low-power laser devices with imbalances in their emission was observed. In most cases, low-power laser devices are not properly maintained. Equipment should be timely calibrated in order to offer safe and effective therapy to users.

4.
Rev. mex. ing. bioméd ; 43(3): 1298, Sep.-Dec. 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1450144

RESUMO

ABSTRACT Spirometry is a test for the diagnosis of chronic obstructive pulmonary disease. It is a technique that can be intolerant due to the essential use of a mouthpiece and a clamp. This study proposes the use of electrical impedance tomogra phy to measure respiratory parameters. Patients underwent spirometry and three respiratory exercises. The imped ance signals were convolved, and the resultant was analyzed by fast Fourier transform. The frequency spectrum was divided into seven segments (R1 to R7). Each segment was represented in terms of quartiles (Q25%, Q50%, Q75%). Each quartile of each segment was correlated with the spirometric parameters to obtain a fitting equation. FVC was correlated 70% with the 3 quartiles of R7, 3 equations were obtained with a fit of 60%. FEV1 correlated 70% with the Q50% of R7, obtaining an equation with a fit of 40%. FEV1/FVC correlated 69% with Q75% of R2, obtaining an equation with a fit of 60%. Spirometric parameters can be estimated from the implied carrier frequency components of the ventilatory impedance signal.


RESUMEN La espirometría es una prueba para el diagnóstico de enfermedad pulmonar obstructiva crónica. Es una técnica que puede resultar intolerante debido al uso imprescindible de una boquilla y una de pinza. Este estudio propone el uso de la tomografía de impedancia eléctrica para medir los parámetros respiratorios. Los pacientes realizaron una espi rometría y tres ejercicios respiratorios. Las señales de impedancia fueron convolucionadas, y la resultante se analizó mediante una transformada rápida de Fourier. El espectro en frecuencias se dividió en siete segmentos (R1 a R7). Cada segmento se representó en términos de cuartiles (Q25%, Q50%, Q75%). Cada cuartil de cada segmento se co rrelacionó con los parámetros espirométricos para obtener una ecuación de ajuste. La FVC se correlacionó en un 70% con los 3 cuartiles de R7, se obtuvieron 3 ecuaciones con un ajuste del 60%. El FEV1 se correlacionó en un 70% con el Q50% de R7, obteniéndose una ecuación con un ajuste del 40%. El FEV1/FVC se correlacionó en un 69% con el Q75% de R2, obteniéndose una ecuación con un ajuste del 60%. Los parámetros espirométricos pueden ser estimados a partir de los componentes de frecuencia portadora implícitos de la señal de impedancia ventilatoria.

5.
Artigo em Inglês | MEDLINE | ID: mdl-36195255

RESUMO

INTRODUCTION: Among the objectives in treatments with yttrium-90 spheres, is to demonstrate that the tumoricidal dose is achieved and that hepatotoxic doses are avoided, as well as that there is no extrahepatic deposition. MATERIAL AND METHODS: We use different amounts of yttrium-90 resin micro-spheres and a NEMA NU2-2007 phantom to check if the scanner maintains a response that allows real dosimetric calculations. RESULTS: The Gemini tomograph responds linearly in a wide range of activities with R2 = 0.9983. CONCLUSION: The detection capacity of the PET equipment allows us to carry out standard body studies with dosimetric purposes with times of five minutes per bed. It also make possible to verify the absence of extrahepatic deposition of significant amounts of yttrium 90 spheres.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons , Calibragem , Radioisótopos de Ítrio/uso terapêutico
6.
Psicol. Caribe ; 39(2): 3-3, mayo-ago. 2022. tab
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1406362

RESUMO

Resumen. Si bien la investigación sobre la metacognición y los estilos cognitivos es sólida para cualquier campo solo, pocas investigaciones han abordado los dos juntos. Además, ningún estudio hasta la fecha ha examinado objetivos más específicos relacionados con aspectos específicos de la metacognición, como la habilidad de monitoreo y su relación con el estilo cognitivo. Por lo tanto, el presente estudio investigó medidas de confianza, rendimiento y precisión para tres tipos de juicios metacognitivos (predicción, concurrente y postdicción) y tres tipos diferentes de preguntas metacognitivas: preguntas sobre la tarea, preguntas sobre uno mismo y preguntas en diferentes momentos (antes, durante y después) y cómo se relacionan con el estilo cognitivo (dependiente del campo, intermedio, independiente del campo) en una muestra de 57 estudiantes universitarios colombianos. Los resultados revelaron que había diferencias en la precisión y el sesgo del monitoreo metacognitivo en función del estilo cognitivo, y que estos hallazgos fueron similares entre los diferentes momentos y entre los juicios metacognitivos. Con respecto al estilo cognitivo, aquellos con un estilo cognitivo intermedio o independiente del campo informaron una mayor precisión de monitoreo y menos sesgo que las personas con un estilo dependiente del campo. Se discuten las implicaciones para la investigación, la teoría y la práctica.


Abstract. While research on metacognition and cognitive styles is robust for either field alone, few studies have broached the two together. In addition, no studies to date have examined finer-grained objectives related to specific aspects of metacognition such as monitoring skill and its relation to cognitive style. Thus, the present study investigated confidence, performance, and accuracy measures for three types of metacognitive judgments (prediction, concurrent and postdiction) and three different types of metacognitive questions-questions about the task, questions about the self, and questions at different moments (before, during, and after)-and how these are related to cognitive style (field dependent, intermediate, field independent) in a sample of 57 Colombian university students. Results revealed that there were differences in metacognitive monitoring accuracy and bias as a function of cognitive style, and that these findings were similar both between different moments and across metacognitive judgments. Regarding cognitive style, those with an intermediate or field independent cognitive style reported greater monitoring accuracy and less bias than individuals with a field dependent style. Implications for research, theory, and practice are discussed.

7.
Poblac. salud mesoam ; 19(2)jun. 2022.
Artigo em Espanhol | LILACS, SaludCR | ID: biblio-1386957

RESUMO

Resumen Introducción: el laboratorio de citogenética del Instituto de Investigaciones en Salud (INISA) de la Universidad de Costa Rica estableció un Servicio de Dosimetría Biológica en enero del 2020 utilizando biomarcadores citogenéticos de exposición a radiaciones ionizantes. Es el primero de su tipo en la región centroamericana. Objetivo: establecer un servicio de dosimetría biológica para Costa Rica, elaborando una curva de calibración dosis-efecto para rayos gamma. Metodología: para la realización de la curva de calibración se irradiaron muestras de sangre periférica in vitro con rayos gamma de dos voluntarios, uno femenino y otro masculino, en 11 puntos de dosis en el rango de 0 a 5 Gy. Se cultivó la sangre acorde a los protocolos internacionales durante 48 horas y se registraron las aberraciones inducidas. Los programas Dose Estimate V5.2 y R versión 4.03 se utilizaron para el cálculo de los coeficientes de la curva de calibración que correlaciona la frecuencia de cromosomas dicéntricos con la dosis. Resultados: los coeficientes de la curva son α: 0.02737±0.00658, ß: 0,05938±0,00450 y C: 0.00129±0.00084. Estos coeficientes tienen valores similares a los reportados internacionalmente. La curva se validó calculando dos dosis incógnitas, en la primera incógnita la dosis suministrada fue de 1,5 Gy y la dosis estimada fue 1,47 Gy y en la segunda la dosis suministrada fue de 4 Gy y la dosis estimada fue 3,616 Gy, para ambos casos no existen diferencias estadísticamente significativas entre las dosis suministradas y las estimadas. Conclusiones: actualmente El Servicio de Dosimetría Biológica del INISA puede estimar dosis absorbida en personas que se sospecha de una sobre exposición a rayos gamma en personal ocupacionalmente expuesto o personas involucradas en un accidente radiológico.


Abstract Introduction. The cytogenetics laboratory of the Health Research Institute (INISA) of the University of Costa Rica established a Biological Dosimetry Service in January 2020 using cytogenetic biomarkers of exposure to ionizing radiation. It is the first of its kind in the Central American region. Objective: establish a biological dosimetry service for Costa Rica, developing a dose-effect calibration curve for gamma rays. Methodology: to carry out the calibration curve, peripheral blood samples from two volunteers, one female and the other male, were irradiated in vitro with gamma rays, at 11 dose points in the range of 0 to 5 Gy. Blood was cultured according to international protocols for 48 hours and induced aberrations were recorded. The Dose Estimate V5.2 and R version 4.03 programs were used to calculate the coefficients of the calibration curve that correlates the frequency of dicentric chromosomes with the dose. Results: the coefficients of the curve are α: 0.02737 ± 0.00658, ß: 0.05938 ± 0.00450 and C: 0.00129 ± 0.00084. These coefficients have values similar to those reported internationally. The curve was validated by calculating two unknown doses, in the first unknown case the delivered dose was 1.5 Gy and the estimated dose was 1.47 Gy and in the second case the delivered dose was 4 Gy and the estimated dose was 3.616 Gy. for both cases there are no statistically significant differences between the delivered and estimated doses. Conclusions: the Biological Dosimetry Service of the INISA can estimate absorbed dose in persons suspected of overexposure to gamma rays in occupationally exposed personnel or persons involved in a radiological accident.Health is loaded with symbolisms and practical manifestations that differ according to social groups and sociocultural contexts. In order to make everyday life and needs visible, the Theoretical Paradigm of Social Representations provides the theoretical-methodological bases necessary to understand the common sense knowledge associated with health among the Nicaraguan migrant population in Costa Rica. Methodology: Qualitative study with ethnographic approach that aimed to identify the social representation of health, through the process of objectification, present among Nicaraguan migrants living in Costa Rica. Data collected through semi-structured interviews, participant observation, and field diaries. Processing according to Content Analysis. Results: The social representation of health found behaves analogously to a formula; where, the search for peaceful environments is added to the achievement of financial stability to result in two interdependent representations: 1) Health as physical-mental strength; and 2) Health as a future and abstract sensation of well-being, happiness and transcendence. The socio-political antecedents in Nicaragua, the migratory process, and the adaptation to Costa Rica play a preponderant role in shaping the representation on health. Conclusion: Social representations about health have direct practical implications on the ways of life and needs of migrant groups. Understanding their common sense knowledge allows to move towards more contextualized public policies. More integration of the thoughts, opinions and feelings of migrants in decision-making platforms is recommended.


Assuntos
Humanos , Masculino , Feminino , Radiação Ionizante , Dosimetria , Costa Rica , Raios gama
8.
Arch Esp Urol ; 75(2): 95-102, 2022 Mar.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-35332878

RESUMO

OBJECTIVE: The  aim of this article is to review and illustrate the attributes that analyze the performance of a predictive model, suchas discrimination, calibration and clinical utility. MATERIAL AND METHODS: To illustrate a biomarkervalidation process, we analyzed 216 patientsrecruited in the Miguel Servet University Hospital Zaragoza, Spain. The outcome of the study was clinicallysignificant prostate cancer (Gleason ≥ 7). A newbiomarker was built using logistic regression modelfrom age, prostate-specific antigen, prostate volumeand digital rectal exam variables. To analyze the discriminationability, the receiver operating characteristiccurve, its area under the curve (AUC), and Youdenindex were estimated. In addition, the calibration wasanalyzed through calibration curve, intercept and slope;and the clinical utility was studied by means of decisionand clinical utility curves. RESULTS: The discrimination ability was good:AUC 0.790 (0.127-0.853 95% C.I.), Youden index cutoffpoint 0.431 (specificity 0.811, sensitivity 0.697).The Intercept was 0 and Slope 1 showing a perfect calibration.Decision curve showed good net benefit in athreshold probability range 25%-80%. Clinical utilitycurve showed that for a 18% cutoff point, a minimum4.5% of CsPCa patients are wrongly classified belowthe cutoff point, saving 18.5% biopsies. CONCLUSIONS: A complete validation process isnecessary to analyze the performance of a biomarkerin oncology, based on their discrimination ability, theconcordance between predicted and actual occurrenceof the outcome, and its applicability in clinical practice.


OBJETIVO: El objetivo principal de esteartículo es revisar e ilustrar las propiedades para analizarel desempeño de un modelo predictivo, que sonla discriminación, calibración y utilidad clínica.MATERIAL Y MÉTODOS: Para ilustrar un procesode validación de biomarcadores, analizamos 216 pacientesreclutados en el Hospital Universitario MiguelServet, Zaragoza, España. El objetivo a predecir en elestudio fue un cáncer de próstata clínicamente significativo(Gleason ≥ 7). Se construyó un nuevo biomarcadorutilizando un modelo de regresión logísticausando la edad, el antígeno prostático específico, elvolumen de la próstata y el tacto rectal como variablespredictoras. Para analizar la capacidad de discriminaciónse estimó la curva característica de funcionamientodel receptor, su área bajo la curva (AUC) y elíndice de Youden. Además, la calibración se analizómediante curva de calibración, intersección y pendiente;y la utilidad clínica se estudió mediante curvasde decisión y utilidad clínica. RESULTADOS: La capacidad de discriminación fuebuena: AUC 0,790 (0,127-0,853 IC del 95%), punto decorte del índice de Youden 0,431 (especificidad 0,811,sensibilidad 0,697). La intersección fue 0 y la pendiente1, mostrando una calibración perfecta. La curva dedecisión muestra un buen beneficio neto en un rangode probabilidad del 25% al 80%. La curva de utilidadclínica mostró que para un punto de corte del 18%, seproduce un mínimo del 4,5% de los pacientes con CsPCaclasificados incorrectamente por debajo del puntode corte, ahorrando un 18,5% de biopsias. CONCLUSIONES: Es necesario un proceso de validacióncompleto para analizar el desempeño de un biomarcadoren oncología, en función de su capacidad dediscriminación, la concordancia entre las prediccionesque proporciona el marcador y la ocurrencia real delevento, y su aplicabilidad en la práctica clínica.


Assuntos
Neoplasias da Próstata , Biópsia , Humanos , Modelos Logísticos , Masculino , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/patologia , Espanha
9.
Arch. esp. urol. (Ed. impr.) ; 75(2): 95-102, mar. 28, 2022. graf
Artigo em Espanhol | IBECS | ID: ibc-203670

RESUMO

OBJETIVO: El objetivo principal de esteartículo es revisar e ilustrar las propiedades para analizar el desempeño de un modelo predictivo, que sonla discriminación, calibración y utilidad clínica.MATERIAL Y MÉTODOS: Para ilustrar un procesode validación de biomarcadores, analizamos 216 pacientes reclutados en el Hospital Universitario MiguelServet, Zaragoza, España. El objetivo a predecir en elestudio fue un cáncer de próstata clínicamente significativo (Gleason ≥ 7). Se construyó un nuevo biomarcador utilizando un modelo de regresión logísticausando la edad, el antígeno prostático específico, elvolumen de la próstata y el tacto rectal como variablespredictoras. Para analizar la capacidad de discriminación se estimó la curva característica de funcionamiento del receptor, su área bajo la curva (AUC) y elíndice de Youden. Además, la calibración se analizómediante curva de calibración, intersección y pendiente; y la utilidad clínica se estudió mediante curvasde decisión y utilidad clínica. RESULTADOS: La capacidad de discriminación fuebuena: AUC 0,790 (0,127-0,853 IC del 95%), punto decorte del índice de Youden 0,431 (especificidad 0,811,sensibilidad 0,697). La intersección fue 0 y la pendiente 1, mostrando una calibración perfecta. La curva dedecisión muestra un buen beneficio neto en un rangode probabilidad del 25% al 80%. La curva de utilidadclínica mostró que para un punto de corte del 18%, seproduce un mínimo del 4,5% de los pacientes con CsPCa clasificados incorrectamente por debajo del puntode corte, ahorrando un 18,5% de biopsias.CONCLUSIONES: Es necesario un proceso de validación completo para analizar el desempeño de un biomarcador en oncología, en función de su capacidad dediscriminación, la concordancia entre las prediccionesque proporciona el marcador y la ocurrencia real delevento, y su aplicabilidad en la práctica clínica. (AU)


lustrate the attributes that analyze theperformance of a predictive model, such as discrimination, calibration and clinical utility.MATERIAL AND METHODS: To illustrate a biomarker validation process, we analyzed 216 patientsrecruited in the Miguel Servet University Hospital, Zaragoza, Spain. The outcome of the study was clinically significant prostate cancer (Gleason ≥ 7). A newbiomarker was built using logistic regression modelfrom age, prostate-specific antigen, prostate volumeand digital rectal exam variables. To analyze the discrimination ability, the receiver operating characteristic curve, its area under the curve (AUC), and Youdenindex were estimated. In addition, the calibration wasanalyzed through calibration curve, intercept and slope; and the clinical utility was studied by means of decision and clinical utility curves.RESULTS: The discrimination ability was good:AUC 0.790 (0.127-0.853 95% C.I.), Youden index cutoff point 0.431 (specificity 0.811, sensitivity 0.697).The Intercept was 0 and Slope 1 showing a perfect calibration. Decision curve showed good net benefit in athreshold probability range 25%-80%. Clinical utilitycurve showed that for a 18% cutoff point, a minimum4.5% of CsPCa patients are wrongly classified belowthe cutoff point, saving 18.5% biopsies.CONCLUSIONS: A complete validation process isnecessary to analyze the performance of a biomarkerin oncology, based on their discrimination ability, theconcordance between predicted and actual occurrenceof the outcome, and its applicability in clinical practice. (AU)


Assuntos
Humanos , Masculino , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/patologia , Antígeno Prostático Específico/sangue , Biomarcadores Tumorais/sangue , Modelos Logísticos , Curva ROC , Biópsia , Espanha
10.
Med. lab ; 26(2): 159-175, 2022. tab
Artigo em Espanhol | LILACS | ID: biblio-1393231

RESUMO

Las mediciones confiables, trazables metrológicamente y comparables proporcionan la base racional para la evaluación de la calidad de un resultado y el fortalecimiento de las redes de laboratorios clínicos, lo cual permite mejorar la calidad de atención y la seguridad del paciente. En este documento se revisan los principios básicos que deben seguirse para garantizar la trazabilidad de las mediciones del laboratorio clínico, las ventajas de utilizar métodos trazables, el impacto de no hacerlo, y se discuten las principales limitaciones para relacionar las mediciones con los estándares de medición de referencia apropiados


Reliable, metrologically traceable, and comparable measurements provide the rationale for evaluating the quality of a result and strengthening clinical laboratory networks, thereby improving quality of care and patient safety. This document reviews the basic principles that must be followed to ensure the traceability of clinical laboratory results, the advantages of using traceable methods, the impact of not doing so, and the main limitations in relating measurements to appropriate reference standards


Assuntos
Confiabilidade dos Dados , Kit de Reagentes para Diagnóstico , Padrões de Referência , Calibragem , Equipamentos e Provisões , Sistema Internacional de Unidades
11.
Rev. colomb. cardiol ; 28(5): 410-420, sep.-oct. 2021. tab, graf
Artigo em Espanhol | LILACS, COLNAL | ID: biblio-1357207

RESUMO

Resumen Objetivo: Evaluar la utilidad del índice UDT-65 para la estratificación del dolor torácico en urgencias en una población colombiana en la que se sospecha enfermedad coronaria. Método: Se condujo la validación externa del índice UDT-65 en una cohorte concurrente que incluyó pacientes que ingresaron a urgencias de una clínica cardiovascular en Bogotá con dolor torácico no traumático, y electrocardiograma normal o no diagnóstico. Se evaluaron 1320 pacientes de 18 o más años y se determinó la utilidad del índice en términos de calibración (uso de gráfico, ji al cuadrado para datos agrupados y prueba de bondad de ajuste de Hosmer-Lemeshow) y de capacidad de discriminación del modelo (curva de características operativas del receptor [ROC] y área bajo ella [AUC]). Resultados: El índice UDT-65 en esta población suministró evidencia de su utilidad en términos de calibración y capacidad de discriminación, para efectuar una buena aplicación de él en aquellos pacientes que consulten al servicio de urgencias de una clínica cardiovascular por dolor torácico no traumático de posible origen coronario. La capacidad de discriminación del índice UDT-65 fue adecuada, pues con un área bajo la curva ROC de 0.867 (IC 95% 0-847-0.885), que se acerca al valor obtenido (AUC 0.87) en la población española en que se desarrolló el índice. Conclusiones: Se necesitan más estudios similares en otras instituciones, dado el buen resultado, en beneficio de más pacientes.


Abstract Objective: To evaluate the clinical usefulness, in the emergency service, of the UDT-65 index for chest pain stratification in colombian population with suspected coronary disease. Method: The external validation of the UDT-65 index was conducted in a concurrent cohort that included patients admitted to the emergency service of the cardiovascular clinic in Bogotá with non-traumatic chest pain and normal or non-diagnostic electrocardiogram. 1320 patients were evaluated and the usefulness of this instrument was determined in terms of calibration (use of graph, Chi-square test for group data and the Hosmer-Lemeshow goodness-of-fit test) and discrimination capacity of the model (curve of receiver operating characteristics [ROC] and by finding the area under the curve [AUC]). Results: The UDT-65 index in the population under study, provided evidence of its usefulness in terms of calibration and discrimination capacity; this, in pursuance of a good application of the instrument in those patients who consult the Emergency Department of the cardiovascular clinic for non-traumatic chest pain of possible coronary origin. The discrimination capacity of the UDT65 index was adequate, with an area under the ROC curve of 0.867 (95 % CI 0.847-0.885), which is close in value to the one obtained (AUC 0.87) in the Spanish population where the original index was developed. Conclusions: More similar studies are needed in other institutions, due to the excellent and beneficial outcomes.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Dor no Peito/diagnóstico , Doença das Coronárias/diagnóstico , Síndrome Coronariana Aguda/diagnóstico , Calibragem , Modelos Logísticos , Sensibilidade e Especificidade , Eletrocardiografia
12.
J. health med. sci. (Print) ; 7(4): 231-238, oct.-dic. 2021. ilus, tab
Artigo em Espanhol | LILACS | ID: biblio-1391707

RESUMO

To ensure a reliable verification of a radiation detector, the right parameters for this response verification must be determined and a specific characterization on the detectors of interest must be performed. These were the main pillars of this study, where four Geiger-Müller at the University of Costa Rica's Cyclotron Facilities' main laboratories were studied and characterized using a 137Cs source. First, a verification of the inverse-square law was performed to corroborate the correct measurement by the detectors as the distance from a 137Cs source to the detectors was varied using a new design for a positioner support to ensure repeatability. This verification yielded a potential fit curve with and equation D=670635 x-1.961 (error percentage of 1.95%) and an R2 value of 0.9836. Then, using combinations of copper plates of widths 1.0 mm and 2.0 mm as attenuators between the source and the detectors, the mass attenuation coefficient for copper was obtained only as a reference value for future calibrations of the detectors. The result for this value was 0.040 cm2 /g. The results obtained in this study and the method developed to achieve these results will serve as a base for calibrations of the detectors at these facilities, which will ensure the safety of the patients and personnel in this building.


Para asegurar respuesta correcta de un detector de radiación, se deben determinar los parámetros correctos para esta verificación y debe realizarse una caracterización específica de los detectores de interés. Estos fueron los pilares principales de este estudio, donde se estudiaron y caracterizaron 4 detectores Geiger-Müller en los laboratorios principales del Ciclotrón de la Universidad de Costa Rica utilizando una fuente radiactiva de 137Cs. Primero, se realizó una verificación de la ley del inverso-cuadrado para corroborar la medición correcta de los detectores según se varía la distancia entre la fuente de 137Cs al detector utilizando un diseño nuevo de un soporte posicionador para la fuente que asegura la repetibilidad entre experimentos. Esta verificación resultó en una curva de ajuste potencial de ecuación D=670635x-1,961 (porcentaje de error de 1,95%) y un valor de R2 de 0,9836. Luego, utilizando combinaciones de placas de cobre de espesores 1,0 mm y 2,0 mm como atenuadores entre la fuente y los detectores, se obtuvo el coeficiente de atenuación másico para el cobre como un valor de referencia para futuras calibraciones de los detectores. Este resultado fue de 0,040 cm2/g. Los resultados obtenidos en esta investigación y el método desarrollado para lograr estos resultados servirán como una base para una futura confirmación metrológica calibraciones de los detectores en estos laboratorios, lo cual colaborará con la seguridad y protección radiológica de pacientes y trabajadores en este edificio.


Assuntos
Monitoramento de Radiação/instrumentação , Monitoramento de Radiação/métodos , Radiometria/instrumentação , Radiometria/métodos , Universidades , Calibragem , Radioisótopos de Césio , Ciclotrons , Exposição à Radiação/análise , Exposição à Radiação/prevenção & controle , Costa Rica
13.
Rev. chil. nutr ; 48(5)oct. 2021.
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1388538

RESUMO

RESUMEN Los Cuestionarios de Frecuencia de Consumo de Alimentos son herramientas de investigación ampliamente utilizadas a nivel poblacional para evaluar la ingesta alimentaria, especialmente en niños. Los objetivos de este estudio fueron construir y determinar la validez relativa del Cuestionario de Frecuencia de Consumo de Alimentos (CFCA) para la evaluación de la ingesta entre niños ecuatorianos en edad escolar. Fueron incluidos 100 niños entre 6 y 8 años de edad de zonas costeras rurales del Ecuador. Las madres completaron 1 CFCA y 2 Recordatorios de 24 horas (R24h, estándar oro). Se utilizaron correlaciones de Pearson, Kappa ponderado y el método de Bland Altman para evaluar su validez. Se aplicaron modelos de regresión lineal incluyendo el R24h como variable dependiente y CFCA como variable independiente para derivar factores de calibración. Los coeficientes de Pearson oscilaron entre -0,03 y 0,24. Los valores de Kappa variaron entre -0,05 y 0,24, los gráficos de Bland-Altman se encuentran entre los límites cerca de la línea media y los factores de calibración oscilaron entre -0,01 a 0,16. Después de aplicar los factores de calibración, las ingestas medias de energía, macro y micro nutrientes fueron similares a las obtenidas en el R24h. El CFCA fue considerado apropiado para evaluar consumo de energía y nutrientes, sin embargo, debido a su concordancia débil a moderada este debe ser corregido mediante los valores de calibración. Asimismo, este CFCA es una herramienta útil para la evaluación de la dieta y la relación entre la dieta y la enfermedad en este grupo poblacional.


ABSTRACT Food frequency questionnaires are research tools widely used at the population level to assess food intake, especially in childhood. The objectives of this study were to develop and determine the relative validity of the Food Frequency Questionnaire (FFQ) for the evaluation of food intake among Ecuadorian schoolchildren. One hundred children from rural coastal areas of Ecuador, aged 6 to 8 years, were included. Mothers completed 1 FFQ frequency and two 24-hour recalls (R24h gold standard). Pearson correlation, weighted Kappa and the Bland Altman method were used to assess validity. Linear regression models were used including R24h as a dependent variable and FFQ as an independent variable to derive calibration factors. The Pearson coefficients ranged between -0.03 and 0.24. The Kappa values varied between -0.05 and 0.24, the Bland-Altman plots were between the limits near the midline and the calibration factors ranged from -0.01 to 0.16. The FFQ was considered appropriate to evaluate energy and nutrient consumption, however, due to its weak to moderate agreement this must be corrected using calibration values. This FFQ is a useful tool for evaluating diet and the relationship between diet and disease in this population group.

14.
J. oral res. (Impresa) ; 10(3): 1-10, jun. 30, 2021. ilus, tab
Artigo em Inglês | LILACS | ID: biblio-1390974

RESUMO

Introduction: Dental malocclusion is a public health problem and orthodontics is the specialty in charge of diagnosing and treating it, aesthetic brackets are an alternative, the costs are varied, which makes its precision doubtful. Objective: Evaluate the measurement and geometry of the slot of three brands of aesthetic brackets and verify their precision. Material and Methods: Twenty-four aesthetic Roth prescription 0.022" slot polycrystalline ceramic brackets were evaluated in three brands: American Orthodontics (United States), Morelli (Brazil) and Class One (China). Eight samples were measured per group in a specialized laboratory certified in measurement and calibration, the measurements of internal and external height were verified, per mesial and distal; and the parallelism of the slot of each bracket. The results were processed with SPSS 22 and tests of variance (ANOVA), Tukey and Student's t were used. Results:The measurements of the brackets' grooves do not correspond to the measurements announced by the manufacturers, these are greater, however, American Orthodontics is within the tolerance range (p<0.01); the slots in the mesio-distal direction and the lingual vestibule are not parallel in Morelli and Class One. Conclusion: The results of this study indicate that the slots of the supports are oversized, their geometry is not precise and varies greatly between brands and prices. The three-dimensional control of the tooth could be compromised.


Introducción: La maloclusión dental es un problema de salud pública y la ortodoncia es la especialidad encargada de diagnosticarla y tratarla, los brackets estéticos son una alternativa, los costos son variados lo que hace dudar su precisión. Objetivo: Evaluar la medida y geometría de la ranura de tres marcas de brackets estéticos y corroborar su precisión. Material y Métodos: Se evaluaron 24 brackets estéticos cerámicos policristalinos de ranura 0,022" prescripción Roth en tres marcas: American Orthodontics (Estados Unidos), Morelli (Brasil) y Class One (China). Se midieron ocho muestras por grupo en un laboratorio especializado y certificado en medición y calibración, se verificaron las medidas de altura interna y externa, por mesial y distal; y el paralelismo de la ranura de cada brackets. Los resultados fueron procesados con SPSS 22 y se utilizaron pruebas de varianza (ANOVA), Tukey y t de Student. Resultados: Las medidas de las ranuras de los brackets no se corresponden con la medida anunciada por los fabricantes, estas son mayores, sin embargo, American Orthodontics y Morelli se encuentra dentro del rango de tolerancia (p<0,01); las ranuras en sentido mesio distal y vestíbulo lingual no son paralelas estadísticamente en Morelli y Class One. Conclusión: Los resultados de este estudio indican que las ranuras de los soportes se encuentran sobredimensionadas, su geometría no es precisa y varía mucho entre marcas y precios. El control tridimensional del diente se podría ver comprometido.


Assuntos
Humanos , Ortodontia Corretiva/métodos , Braquetes Ortodônticos , Desenho de Aparelho Ortodôntico , Cerâmica , Estudos Transversais , Má Oclusão
15.
Rev. cienc. med. Pinar Rio ; 24(5): e4592, sept.-oct. 2020. tab, graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1144294

RESUMO

RESUMEN Introducción: en Cuba, en el 2018, fueron diagnosticados un total de 12 070 nuevos casos de cáncer de piel, de los cuales se estima que 11 587 corresponden a la variante no melanómica. La radioterapia con rayos x está considerada como la primera opción de tratamiento en muchos de estos casos. Recientemente, el sistema nacional de salud, adquirió cuatro equipos de la marca SENSUS SRT-100TM para el tratamiento del NMSC. Objetivo: desarrollar una metodología estandarizada para la caracterización dosimétrica de los equipos de radioterapia superficial con rayos X instalados en Cuba. Métodos: se caracterizaron cuatro equipos de radioterapia SENSUS SRT-100TM para cada una de sus calidades radiológicas, en términos de linealidad, estabilidad, capa hemirreductora, tasas de dosis de referencia, perfiles de dosis, factores de cono y porcentaje de dosis en profundidad. Se emplearon para ello, las recomendaciones de la AAPM TG-61 y el IAEA-TRS 398. Resultados: lo promedios de las HVLs (mm Al) y sus respectivos coeficientes de variación (CV) fueron de 5,526 - 5,2 %; 1,130 - 2,1 % y 2,007 - 2,1 % para 50,70 y 100 kV respectivamente. Los rendimientos presentaron poca variabilidad entre máquinas (CV < 3%) y fueron muy similares por los métodos "en agua" y "en aire" (discrepancia. < 0,5 %). Conclusiones: los equipos muestran una excelente estabilidad, y características dosimétricas muy similares entre ellos, lo cual permite establecer valores de referencia para eventuales auditorías externas y re-ajustes de los haces ulteriormente a los mantenimientos o reparaciones que impliquen al generador de rayos X.


ABSTRACT Introduction: in Cuba, in 2018, a total of 12 070 new cases of skin cancer were diagnosed, from which it is estimated that 11 587 correspond to the non-melanoma type. Radiation therapy with X-rays is considered the first-line treatment in many of these cases. Recently, the national healthcare system acquired four SENSUS SRT-100TM units for treating Non-Melanoma Skin Cancer (NMSC). Objective: to develop a standardized methodology for the dosimetric characterization of the equipments of surface radiotherapy with X-rays installed in Cuba. Methods: four SENSUS SRT-100TM radiotherapy equipments were characterized for each of their radiological qualities, in terms of linearity, stability, hemi-reductive layer, reference dose rates, dose profiles, cone factors and percentage of dose in depth. The recommendations of the AAPM TG-61 and the IAEA-TRS 398 were applied for this purpose. Results: the averages of HVLs (mm Al) and their respective coefficients of variation (CV) were 5,526 - 5,2 %; 1,130 - 2,1 % and 2,007 - 2,1 % for 50, 70 and 100 kV respectively. The yields presented little variability between machines (CV < 3%) and were very similar by the methods "in water" and "in air" (discrepancy < 0,5 %). Conclusions: the equipments show excellent stability and very similar dosimetric characteristics among them, which allows establishing reference values for eventual external audits and beam readjustments after the maintenance or repairs involving the X-ray generator.

16.
Nucleus (La Habana) ; (65): 47-50, ene.-jun. 2019. tab
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1091389

RESUMO

Abstract In the present work, we introduce the theoretical development and a new approach to validate a novel method to calibrate the efficiency of a gamma radiation detector for point sources, which we have named the "Efficiency Extrapolation Method". The method consists in the determination of the detector efficiency using a set of monoenergetic gamma sources, which we will refer to as reference efficiencies. From these values, we will extrapolate the detector efficiency to the complete energy range using the first principle physics of gamma radiation detection theory. Therefore the proposed method corresponds to a semi-empirical one. The determination of reference efficiencies must be done experimentally, but in this work, simulations were performed using FLUKA code. The reference energies will be: 59,54 keV, 661,66 keV and 1 274,54 keV associated to the isotopes 241Am, 137Cs and 22Na respectively. The second part of the method, the extrapolation from the reference energies to the gamma range, will be done over the energies emitted by 152Eu and 133Ba. In general, the results are very good. While the obtained results for energies 53,16 keV and greater than 344,3 keV show an excellent agreement, the results obtained for energies in the middle range are only good.


Resumen En el presente trabajo presentamos el desarrollo teórico y un nuevo enfoque para validar un nuevo método para calibrar la eficiencia de un detector de radiación gamma para fuentes puntuales, al cual hemos llamado el método de extrapolación de la eficiencia. El método consiste en la determinación de la eficiencia del detector usando un conjunto de fuentes gamma monoenergéticas, a las cuales llamaremos eficiencias de referencia. Desde estos valores, extrapolaremos la eficiencia del detector al rango completo de energías usando la física de primeros principios de la teoría de detección de radiación gamma. Por lo tanto el método propuesto corresponde a un método semiempírico. La determinación de las eficiencias de referencia debe hacerse experimentalmente, pero en este trabajo, se realizaron simulaciones usando el código FLUKA. Las energías de referencia serán: 59,54 keV, 661,65 keV y 1 274,54 keV asociadas a los isótopos 241 Am, 137Cs y 22Na respectivamente. La segunda parte del método, la extrapolación desde las energías de referencia hacia el rango gamma de las energías, será realizada sobre las energías emitidas por los isótopos 152Eu y 133Ba. En general, los resultados son muy buenos. Mientras que los resultados obtenidos para las energías de 53,16 keV y mayores que 344,3 keV muestran un excelente acuerdo, los resultados obtenidos para las energías del rango intermedio son solo buenas.

17.
Nucleus (La Habana) ; (65): 51-55, ene.-jun. 2019. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1091390

RESUMO

Abstract Total Body Irradiation (TBI) is a radiotherapy technique that consists of irradiating homogeneously the whole patient's body and it is characterized by an extended source to surface distances and the use of large irradiation fields. The limitations of the available input data and inherent problems with the calculation procedures make it very difficult to accurately determine the dose distributions in TBI. For these reasons, it is highly recommended to use In Vivo Dosimetry (IVD), to guarantee the quality of TBI treatments as a direct measurement of the delivered dose. An IVD QA system was implemented based on semiconductor diodes and radiochromic films. For the commissioning of the system, both detector types were calibrated independently, using as reference an ionization chamber with a valid certificate in terms of absorbed dose to water (Dw). This guarantees the traceability of the measurements. An experiment was carried out to simulate a clinical TBI procedure to a phantom. In this way, the calibration of the dosimetry system was confirmed.


Resumen La irradiación total del cuerpo (TBI) es una técnica de radioterapia que consiste en irradiar de manera homogénea todo el cuerpo del paciente y se caracteriza por una fuente extendida a distancias superficiales y el uso de grandes campos de irradiación. Las limitaciones de los datos de entrada disponibles y los problemas inherentes con los procedimientos de cálculo hacen que sea muy difícil determinar con precisión las distribuciones de dosis en TBI. Por estos motivos, es altamente recomendable utilizar la dosimetría in vivo (IVD), para garantizar la calidad de los tratamientos de TBI como una medida directa de la dosis administrada. Se implementó un sistema IVD QA basado en diodos semiconductores y películas radiocromáticas. Para la puesta en marcha del sistema, ambos tipos de detectores se calibraron de forma independiente, utilizando como referencia una cámara de ionización con un certificado válido en términos de dosis absorbida en agua (Dw). Esto garantiza la trazabilidad de las mediciones. Se llevó a cabo un experimento para simular un procedimiento clínico de TBI a un fantasma. De esta forma, se confirmó la calibración del sistema de dosimetría.

18.
Nucleus (La Habana) ; (64): 24-29, July.-Dec. 2018. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1002724

RESUMO

Abstract The advanced GaAs:Cr material for radiation detection is in the scope of many scientific and technological institutions in the world, as a result of its proved superior properties and economic advantages. The energy calibration of a hybrid GaAs:Cr-based Timepix detector with alpha particles performed in the Dzhelepov Laboratory of Nuclear Problems at Joint Institute for Nuclear Research confirms that the device is able to register these particles in energy range from 3140 to 7687 keV. The mathematical simulation was used to calculate the transmitted energy, making possible the experimental calibration with the use of Mylar as absorbent. By calibrating the detector with characteristic X rays of some target materials and using a two steps fitting procedure was determined the relationship between the photon energies and the registered by the detector TOT counts. The energy calibration with alpha particles was performed according to a linear function and verified with the measurement of the 218Po line of radon in air.


Resumen El GaAs:Cr como material de avanzada para la detección de las radiaciones se encuentra en la mira de muchas instituciones científicas y tecnológicas en el mundo, como consecuencia de sus superiores propiedades y ventajas económicas. Los experimentos hechos en el Laboratorio de Problemas Nucleares Dzhelepov del Instituto Unificado de Investigaciones Nucleares para la calibración energética de un detector hibrido Timepix basado en GaAs:Cr con partículas alfa confirma que este dispositivo es capaz de registrar partículas en el rango energético de 3410 a 7687 keV. Se utilizó la simulación matemática para calcular la energía transmitida, haciendo posible la calibración experimental con el uso de Mylar como absorbente. Utilizando la calibración del detector hecha con los rayos X característicos de algunos materiales blanco y empleando un procedimiento de ajuste en dos pasos fue determinada la relación entre la energía de los fotones y los conteos TOT registrados por el detector. Se realizó la calibración energética con partículas alfa de acuerdo con una función lineal y se verificó con la medición de la línea del 218Po del radón en aire.

19.
Nucleus (La Habana) ; (64): 30-36, July.-Dec. 2018. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1002725

RESUMO

Abstract Among the latest ionizing radiation detectors, those based on chromium compensated gallium arsenide (GaAs:Cr) are ones of the most competitive for many applications due to their high Z and strong resistance to radiation damage. They have been used in high energy physics research, medical visualization and spatial technologies, geological prospecting, among other advanced fields. The object of this work is a 900 µm GaAs:Cr detector with Timepix readout technology. Some detector characteristics for three experimental conditions were measured and studied by using the X-rays from a synchrotron and an X-ray tube provided with different materials for obtaining the corresponding fluorescence photons. A complex function was used to decompose the differential spectra into the most important contributions involved. As an additional tool for the research, the mathematical modeling of the mobility of charge carriers generated by radiation within the active volume of the detector was used. The results of these charge sharing effect studies showed a noticeable prevalence in the detector of this effect, changing its contribution according to the experiment characteristics. The detector was calibrated for the planned experiments and the energy resolution was determined. From the analysis of all the obtained results and their comparison with those reported in literature, it was confirmed that the detector has a marked charge-sharing effect between neighboring pixels, being its performance more impaired as the energy of incident photons increases.


Resumen Entre los últimos detectores de radiación ionizante, los basados ​​en arseniuro de galio compensado con cromo (GaAs: Cr) son de los más competitivos para muchas aplicaciones debido a su alto Z y fuerte resistencia al daño de la radiación. Se han utilizado en investigación de física de alta energía, visualización médica y tecnologías espaciales, prospección geológica, entre otros campos avanzados. El objeto de este trabajo es un detector de GaAs: Cr de 900 µm con tecnología de lectura Timepix. Algunas características del detector para tres condiciones experimentales se midieron y estudiaron utilizando rayos X de un sincrotrón y un tubo de rayos X provisto de diferentes materiales para obtener los fotones de fluorescencia correspondientes. Se utilizó una función compleja para descomponer los espectros diferenciales en las contribuciones más importantes involucradas. Como herramienta adicional para la investigación, se utilizó el modelado matemático de la movilidad de los portadores de carga generados por la radiación dentro del volumen activo del detector. Los resultados de estos estudios de efecto de carga compartida mostraron una prevalencia notable en el detector de este efecto, cambiando su contribución según las características del experimento. El detector se calibró para los experimentos planificados y se determinó la resolución de energía. A partir del análisis de todos los resultados obtenidos y su comparación con los reportados en la literatura, se confirmó que el detector tiene un marcado efecto de reparto de carga entre píxeles vecinos, y su rendimiento se ve más afectado a medida que aumenta la energía de los fotones incidentes.

20.
Nucleus (La Habana) ; (64): 37-41, July.-Dec. 2018. graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1002726

RESUMO

Summary The E36 experiment has been carried out at J-PARC to search for Lepton Universality violation in the kaon two body decays K l2 . A precise value of the decay width ratio R K = Γ ( K e 2 ) = Γ ( K μ 2 ) will be extracted and compared with the standard model (SM) value. Any sizable difference would suggest new physics beyond the SM. Simultaneously, E36 is sensitive to light U(1) gauge bosons which could be associated with dark matter or explain established muon-related anomalies (g-2). The experiment as well as the status of the analysis will be presented.


Resumen El experimento E36 se ha llevado a cabo en J-PARC para buscar anomalías a la universalidad leptónica en las desintegraciones en dos leptones del kaón K l2 . Se extraerá un valor preciso de la fracción de anchos de desintegración R K = Γ ( K e 2 ) = Γ ( K μ 2 ) y se comparará con el valor del modelo estándar (SM). Cualquier diferencia considerable sugeriría una nueva física más allá del SM. Simultáneamente, E36 es sensible a los bosones de gauge ligeros U(1) que podrían estar asociados con la materia oscura o explicar anomalías relacionadas con el muón (g-2). El experimento y el estado del análisis serán presentados.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...