Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Acta Ophthalmol ; 2024 05 23.
Artigo em Inglês | MEDLINE | ID: mdl-38780148

RESUMO

PURPOSE: To manage patient dissatisfaction following multifocal intraocular lens (MF-IOL) implantation by IOL exchange with either a monofocal or an alternative MF-IOL, and to compare outcomes in these two groups. METHODS: MF-IOL exchange was performed in 32 patients (64 eyes) with neuroadaptation failure. The MF-to-MF group involved patients who had a MF-IOL exchanged with another MF-IOL of a different optical profile and the MF-to-MO group involved patients who had a MF-IOL exchanged to a monofocal IOL. Visual outcomes and complications were analysed. The Quality of Vision (QoV) questionnaire, Visual Function Index (VF-14) and its Rasch-revised version (VF-8R) were also used to assess outcomes. RESULTS: There were no significant differences (p > 0.05) in the QoV scores between the two groups, both preoperatively and postoperatively. Preoperatively, there were no significant differences in VF-14 scores between both groups (p > 0.05). Postoperatively, there were statistically significant differences in VF-14 (total score, intermediate vision and near vision) in favour of the MF-to-MF group (p < 0.05). The postoperative VF-8R score in the MF-to-MF group was significantly better than the MF-to-MO group (p ≤ 0.001). Uncorrected and corrected near as well as corrected distance visual acuities were significantly better (p < 0.05) in the MF-to-MF group compared to the MF-to-MO group at 3 months. CONCLUSION: Patient dissatisfaction and neuroadaptation failure following MF-IOL implantation can be managed by an IOL exchange with an alternative optical design of MF-IOL or a monofocal IOL. Although, in the current study, the MF-to-MF group showed some better postoperative results, both options are feasible solutions.

2.
Eur J Ophthalmol ; 34(2): 432-439, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37461240

RESUMO

PURPOSE: To report the causes of pseudophakic intraocular lens (IOL) explantation in Spain over a 20 year period. METHODS: Multicenter observational prospective study of a consecutive series of cases corresponding to pseudophakic intraocular lenses explantations performed in 22 Spanish clinical centres from 2002 to 2021, within a national clinical research network. The clinical data of all IOL explantation patients was evaluated, and the different causes for IOL explantation were systematically analyzed. RESULTS: From a total of 1013 pseudophakic explantations, 919 cases were included in this investigation. The mean age of the patients at the time of explantation was 66.3 years, and 142 (15.45%) were women. Over the 20 years of the study, the five main reasons for explanting lenses in the last 20 years in Spain according to the Iberia RETICS database were: dislocation / decentration / misalignment (43.08%), bullous keratopathy (16.79%), neuroadaptation failure (13.85%), IOL opacification (9.71%), refractive surprise (6.87%). Other causes, less frequent, were uveitis / endophthalmitis / infection with 39 cases (4.25%); IOL substitution for reasons other than multifocal IOL neuroadaptation failure 3 cases (0.33%); and other causes, 47 cases (5.13%). Hydrophobic lenses were the most frequently explanted with a ratio of 47.1%. CONCLUSIONS: Over the 20 years of the study, the five main reasons for explanting lenses in the last 20 years in Spain according to the Iberia RETICS database were: dislocation / decentration / misalignment, bullous keratopathy, neuroadaptation failure, IOL opacification, and refractive surprise.


Assuntos
Lentes Intraoculares , Humanos , Feminino , Idoso , Masculino , Espanha/epidemiologia , Estudos Prospectivos , Lentes Intraoculares/efeitos adversos , Complicações Pós-Operatórias/etiologia , Acuidade Visual
3.
Eye Vis (Lond) ; 9(1): 40, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36316701

RESUMO

BACKGROUND: The aim of this study was to evaluate visual, refractive, quality of vision, visual function and satisfaction of multifocal intraocular lens (MF-IOL) exchange with a monofocal IOL (MNF-IOL) in dissatisfied patients following MF-IOL implantation. METHODS: This was a retrospective case series. Bilateral IOL exchange (MF-IOL to MNF-IOL) was performed in 13 patients (26 eyes) with neuroadaptation failure. Questionnaires including the Quality of Vision (QoV), Visual Function Index (VF-14 and Rasch-revised VF-8R version), and a satisfaction questionnaire were used. RESULTS: The mean time for IOL exchange was 15 months. The corrected distance visual acuity (CDVA) improved from 20/26 to 20/23 (P = 0.028). The uncorrected near visual acuity (UNVA) worsened after exchange from 20/47 to 20/62 (P = 0.024). QoV scores improved significantly across all three subscales after exchange. Visual function for far distance improved with a change in VF-14 score from 74.2 ± 24.8 to 90.9 ± 9.1 (P = 0.03). The VF-8R score showed worsening although not statistically significant. Near vision spectacle independence was totally or partially lost in all cases. Ten patients (77%) reported they would not repeat the lens exchange. Safety and efficacy indices changed from 1.23 to 0.85, respectively, at three months to 1.24 (P = 0.871) and 0.89 (P = 0.568), respectively, at one year. CONCLUSION: IOL exchange (multifocal to monofocal) to solve neuroadaptation failure in this case series resulted in significant improvements in dysphotopsia and improved distance visual function. However, UNVA worsened and patient satisfaction after exchange remained suboptimal with 77% claiming they would not repeat the lens exchange, suggesting the value of near vision spectacle independence for these patients.

4.
Eur J Ophthalmol ; 32(3): 1333-1339, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34407662

RESUMO

As techniques for modern cataract surgery have expanded and premium intraocular lens (IOL) use is now widespread, patient expectations are high. The need for IOL explantation, whilst still low, remains an ongoing issue. Intraocular lens explantation can be challenging for a number of reasons and as such we have introduced an additional technique to add to the surgeon's repertoire. Bimanual haptic stripping of fibrosis at the specific area where the haptic is adherent to the capsular bag is an effective strategy to aid in dissection of haptics without compromising the capsule or zonules. Given the challenges associated with IOL explantation, newly designed IOLs need to avoid these "sticking points" at which the IOLs interact with the fibrosed capsule. Techniques we have evolved and which are described below should assist anterior segment surgeons to facilitate IOL removal in an efficient and safe way.


Assuntos
Extração de Catarata , Catarata , Cápsula do Cristalino , Lentes Intraoculares , Humanos , Implante de Lente Intraocular/métodos , Complicações Pós-Operatórias
5.
Eur J Ophthalmol ; : 11206721211049102, 2021 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-34613856

RESUMO

PURPOSE: The aim of this article is to describe an innovative and minimally invasive surgical technique for posterior vitrectomy combined with secondary intraocular lens implantation, using a sutureless scleral fixation Carlevale intraocular lens (I71 FIL SSF Carlevale lens. Soleko IOL Division, Italy). METHODS: The technique was conducted with only three transconjunctival sclerotomies and a corneal tunnel to perform intraocular lens explantation, posterior vitrectomy and Carlevale intraocular lens implantation. It is easier, quicker, and less invasive than the traditional technique with conjunctival peritomy, two scleral flaps and five sclerotomies. RESULTS: Surgery was performed uneventfully on three eyes of three patients. Two of them presented a luxation of the intraocular lens into the vitreous chamber, while one patient presented an intraocular lens subluxation. No complications were observed after a 5 to 8 months of follow-up. The intraocular lenses were well positioned, no conjunctival erosion was noted, and the intraocular pressure remained normal at all stages. CONCLUSIONS: This is the first report of a combined procedure of IOL explantation, posterior vitrectomy and secondary IOL implantation using only three transconjunctival sclerotomies. This appears to be less invasive and it causes less discomfort to the patient. We suggest considering this technique in all those cases requiring a combined procedure in absence of a proper capsular support.

6.
Am J Ophthalmol Case Rep ; 19: 100797, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32760851

RESUMO

PURPOSE: Analysis of explanted intraocular lenses (IOLs) from pseudophakic eyes with supplementary sulcus-supported IOLs. METHODS: In this laboratory investigation, ten supplementary and capsular bag IOLs were analyzed. All lenses were received between January 2012 and March 2018. Explants were examined morphologically with histological and electron microscopic techniques and patients' medical history was evaluated. Additionally, we used a technique new to this field: Transmission Electron Microscopy and electron diffraction pattern analysis was performed to investigate the structure of the opacifying crystals in detail. RESULTS: Eleven lenses were explanted due to IOL opacification from seven polypseudophakic eyes: In three cases the supplementary lens calcified, in three cases the capsular bag IOL (both lenses analyzed) and in one case both IOLs (only the supplementary was received). Additional surgical procedures and comorbidities included pars plana vitrectomy or Descemet stripping endothelial keratoplasty and diabetes mellitus. For each opacified lens, a varying layer of a Calcium phosphate beneath the optic surface was apparent. Crystal characterization revealed its composition to be Hydroxyapatite. CONCLUSIONS AND IMPORTANCE: We report on a series of secondary calcification in lenses explanted from polypseudophakic eyes. In some cases, calcification occurred in the capsular bag lens, in other cases in the supplementary lens, or in both. The severity of the morphological change could be related to the comorbidities and the presence of surgery subsequent to the lens implantations. Detailed morphology of the opacifying crystals was revealed.

7.
Clin Ophthalmol ; 14: 551-555, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32161440

RESUMO

PURPOSE: To compare the outcomes of delayed-onset low-grade endophthalmitis managed with and without intraocular lens (IOL) explantation. SETTING: Tertiary eye-care research institute in southern India. DESIGN: Retrospective comparative case series. METHODS: The study included all cases of post-cataract surgery delayed-onset endophthalmitis from January 1990 to January 2019. Time to endophthalmitis, duration of symptoms, presenting visual acuity, time to IOL explantation when performed, resolution after explantation, number of intravitreal injections, and final visual acuity were compared in the IOL non-explanted and IOL explanted groups. RESULTS: There were 115 eyes - 61 eyes in the IOL non-explant and 54 eyes in the IOL explant group. Between the two groups there was no statistically significant difference in age (58.37 ± 14.05 and 56.04 ± 14.96 years, respectively; p=0.35), vision at presentation (>20/400 in 29.5% and 29.6% eyes, respectively; p=0.98), and the duration of follow-up (14.38 ± 16.05, median 8.5 months and 7.06 ± 3.55, median 6 months respectively; p=0.43). There was a statistically significant difference between the IOL non-explant and IOL-explant groups in the time to resolution of inflammation (92.70 ± 36.28 and 45.33±11.2 days, respectively; p <0.0001) and the number of intravitreal injections (4.57 ± 0.75, median 5 and 2.79±2.11, median 2 respectively, p=0.005). Persistent/recurrent inflammation at 6 months was recorded in 18.03% and 5.55% in the IOL non-explant and IOL explant eyes, respectively (p=0.04). Favorable functional outcome was seen in 50.81% vs 68.51% in IOL non-explant and explant eyes, respectively (p=0.05). CONCLUSION: IOL explantation in delayed-onset endophthalmitis helps in earlier resolution of inflammation, need for lesser number of intravitreal injections and a trend towards better functional outcomes.

8.
Ophthalmologe ; 117(5): 452-455, 2020 May.
Artigo em Alemão | MEDLINE | ID: mdl-31324958

RESUMO

This article reports the case of a 56-year-old male patient who had undergone implantation of posterior chamber phakic intraocular lenses in 1987 in Russia. The patient presented to this clinic 31 years after the initial surgery with anterior cortical cataracts and initial stages of corneal decompensation in both eyes. Strategic planning and execution of surgical treatment and the further clinical course are portrayed in this report.


Assuntos
Catarata , Lentes Intraoculares , Lentes Intraoculares Fácicas , Remoção de Dispositivo , Humanos , Implante de Lente Intraocular , Cristalino , Masculino , Pessoa de Meia-Idade
9.
Transl Vis Sci Technol ; 4(3): 8, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26101721

RESUMO

PURPOSE: To transect intraocular lenses (IOLs) using a femtosecond laser in cadaveric human eyes. To determine the optimal in vitro settings, to detect and characterize gasses or particles generated during this process. METHODS: A femtosecond laser was used to transect hydrophobic and hydrophilic acrylic lenses. The settings required to enable easy separation of the lens fragment were determined. The gasses and particles generated were analysed using gas chromatography mass spectrometer (GC-MS) and total organic carbon analyzer (TOC), respectively. RESULTS: In vitro the IOL fragments easily separated at the lowest commercially available energy setting of 1 µJ, 8-µm spot, and 2-µm line separation. No particles were detected in the 0.5- to 900-µm range. No significant gasses or other organic breakdown by products were detected at this setting. At much higher energy levels 12 µJ (4 × 6 µm spot and line separation) significant pyrolytic products were detected, which could be harmful to the eye. In cadaveric explanted IOL capsule complex the laser pulses could be applied through the capsule to the IOL and successfully fragment the IOL. CONCLUSION: IOL transection is feasible with femtosecond lasers. Further in vivo animal studies are required to confirm safety. TRANSLATIONAL RELEVANCE: In clinical practice there are a number of large intraocular lenses that can be difficult to explant. This in-vitro study examines the possibility of transecting the lasers quickly using femtosecond lasers. If in-vivo studies are successful, then this innovation could help ophthalmic surgeons in IOL explantation.

10.
Case Rep Ophthalmol ; 4(3): 151-4, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24163684

RESUMO

A 79-year-old hyperglycemic patient was referred to the 'Santa Maria delle Croci' Hospital, Ravenna, Italy. He presented with visual impairment in the right eye. Four years ago, he had had an uneventful cataract surgery in the right eye. We observed an opacification of the intraocular lens (IOL) causing significant visual disturbance. The IOL was exchanged. Unfortunately, pathologic analysis was not performed. Patient-related factors such as hyperglycemia and hypertension might have been responsible for the opacification. To our knowledge, there is only one previous report of opacification of the Akreos Adapt AO IOL.

SELEÇÃO DE REFERÊNCIAS