1.
Ultrasound Med Biol ; 2024 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-39122609

RESUMO

OBJECTIVE: The proximal isovelocity surface area (PISA) method is a well-established approach for mitral regurgitation (MR) quantification. However, it exhibits high inter-observer variability and inaccuracies in cases of non-hemispherical flow convergence and non-holosystolic MR. To address this, we present EasyPISA, a framework for automated integrated PISA measurements taken directly from 2-D color-Doppler sequences. METHODS: We trained convolutional neural networks (UNet/Attention UNet) on 1171 images from 196 recordings (54 patients) to detect and segment flow convergence zones in 2-D color-Doppler images. Different preprocessing schemes and model architectures were compared. Flow convergence surface areas were estimated, accounting for non-hemispherical convergence, and regurgitant volume (RVol) was computed by integrating the flow rate over time. EasyPISA was retrospectively applied to 26 MR patient examinations, comparing results with reference PISA RVol measurements, severity grades, and cMRI RVol measurements for 13 patients. RESULTS: The UNet trained on duplex images achieved the best results (precision: 0.63, recall: 0.95, dice: 0.58, flow rate error: 10.4 ml/s). Mitigation of false-positive segmentation on the atrial side of the mitral valve was achieved through integration with a mitral valve segmentation network. The intraclass correlation coefficient was 0.83 between EasyPISA and PISA, and 0.66 between EasyPISA and cMRI. Relative standard deviations were 46% and 53%, respectively. Receiver operator characteristics demonstrated a mean area under the curve between 0.90 and 0.97 for EasyPISA RVol estimates and reference severity grades. CONCLUSION: EasyPISA demonstrates promising results for fully automated integrated PISA measurements in MR, offering potential benefits in workload reduction and mitigating inter-observer variability in MR assessment.

2.
Magn Reson Med ; 92(4): 1484-1495, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38725423

RESUMO

PURPOSE: To develop and evaluate a phase unwrapping method for cine phase contrast MRI based on graph cuts. METHODS: A proposed Iterative Graph Cuts method was evaluated in 10 cardiac patients with two-dimensional flow quantification which was repeated at low venc settings to provoke wrapping. The images were also unwrapped by a path-following method (ROMEO), and a Laplacian-based method (LP). Net flow was quantified using semi-automatic vessel segmentation. High venc images were also wrapped retrospectively to asses the residual amount of wrapped voxels. RESULTS: The absolute net flow error after unwrapping at venc = 100 cm/s was 1.8 mL, which was 0.83 mL smaller than for LP. The repeatability error at high venc without unwrapping was 2.5 mL. The error at venc = 50 cm/s was 7.5 mL, which was 8.2 mL smaller than for ROMEO and 5.7 mL smaller than for LP. For retrospectively wrapped images with synthetic venc of 100/50/25 cm/s, the residual amount of wrapped voxels was 0.00/0.12/0.79%, which was 0.09/0.26/8.0 percentage points smaller than for LP. With synthetic venc of 25 cm/s, omitting magnitude information resulted in 3.2 percentage points more wrapped voxels, and only spatial/temporal unwrapping resulted in 4.6/21 percentage points more wrapped voxels compared to spatiotemporal unwrapping. CONCLUSION: Iterative Graph Cuts enables unwrapping of cine phase contrast MRI with very small errors, except for at extreme blood velocities, with equal or better performance compared to ROMEO and LP. The use of magnitude information and spatiotemporal unwrapping is recommended.


Assuntos
Algoritmos , Imagem Cinética por Ressonância Magnética , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Reprodutibilidade dos Testes , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Feminino , Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Estudos Retrospectivos , Pessoa de Meia-Idade
4.
Magn Reson Med ; 92(2): 807-819, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38469904

RESUMO

PURPOSE: To develop and validate a noninvasive imaging technique for accurately assessing very slow CSF flow within shunt tubes in pediatric patients with hydrocephalus, aiming to identify obstructions that might impede CSF drainage. THEORY AND METHODS: A simulation of shunt flow enhancement of signal intensity (shunt-FENSI) signal is used to establish the relationship between signal change and flow rate. The quantification of flow enhancement of signal intensity data involves normalization, curve fitting, and calibration to match simulated data. Additionally, a phase sweep method is introduced to accommodate the impact of magnetic field inhomogeneity on the flow measurement. The method is tested in flow phantoms, healthy adults, intensive care unit patients with external ventricular drains (EVD), and shunt patients. EVDs enable shunt-flow measurements to be acquired with a ground truth measure of CSF drainage. RESULTS: The flow-rate-to-signal simulation establishes signal-flow relationships and takes into account the T1 of draining fluid. The phase sweep method accurately accounts for phase accumulation due to frequency offsets at the shunt. Results in phantom and healthy human participants reveal reliable quantification of flow rates using controlled flows and agreement with the flow simulation. EVD patients display reliable measures of flow rates. Shunt patient results demonstrate feasibility of the method and consistent flow rates for functional shunts. CONCLUSION: The results demonstrate the technique's applicability, accuracy, and potential for diagnosing and noninvasively monitoring hydrocephalus. Limitations of the current approach include a high sensitivity to motion and strict requirement of imaging slice prescription.


Assuntos
Derivações do Líquido Cefalorraquidiano , Hidrocefalia , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Humanos , Hidrocefalia/diagnóstico por imagem , Hidrocefalia/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Adulto , Masculino , Feminino , Reprodutibilidade dos Testes , Simulação por Computador , Criança , Líquido Cefalorraquidiano/diagnóstico por imagem , Líquido Cefalorraquidiano/fisiologia , Algoritmos , Processamento de Imagem Assistida por Computador/métodos
5.
J Nucl Cardiol ; 34: 101825, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38387736

RESUMO

BACKGROUND: It is clinically needed to explore a more efficient imaging protocol for single photon emission computed tomography (SPECT) myocardial blood flow (MBF) quantitation derived from cadmium zinc telluride (CZT) SPECT camera for the routine clinical utilization. METHODS: One hundred and twenty patients with matched clinical characteristics and angiographic findings who completed one-day rest/stress SPECT imaging with either the intermittently sequential imaging (ISI) protocol (two dynamic and two electrocardiography (ECG)-gated scans) or the continuous rapid imaging (CRI) protocol (two dynamic/ECG-gated scans) were included. MBF quantitation adopted residual activity correction (RAC) to correct for rest residual activity (RRA) in the stress dynamic SPECT scan for the detection of flow-limited coronary artery disease. RESULTS: The CRI protocol reduced about 6.2 times shorter than the ISI protocol (25.5 min vs 157.6 min), but slightly higher than the RRA (26.7% ± 3.6% vs 22.3% ± 4.9%). With RAC, both protocols demonstrated close stress MBF (2.18 ± 1.13 vs 2.05 ± 1.10, P > 0.05) and myocardial flow reserve (MFR) (2.42 ± 1.05 vs 2.48 ± 1.11, P > 0.05) to deliver comparable diagnostic performance (sensitivity = 82.1%-92.3%, specificity = 81.2%-91.2%). Myocardial perfusion and left ventricular function overall showed no significant difference (all P > 0.26). CONCLUSION: One-day rest/stress SPECT with the CRI protocol and rest RAC is feasible to warrant the diagnostic performance of MBF quantitation with a shortened examination time and enhanced patient comfort. Further evaluation on the impact of extracardiac activity to regional MBF and perfusion pattern is required. Additional evaluation is needed in a patient population that is typical of those referred for SPECT MPI, including those with known or suspected coronary microvascular disease.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Imagem de Perfusão do Miocárdio , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Cádmio , Estudos de Viabilidade , Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Telúrio , Zinco
6.
J Appl Physiol (1985) ; 136(3): 555-566, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38234292

RESUMO

Ventricular-vascular coupling in endurance athletes remains incompletely understood. The purpose of this study was to determine the ascending aortic impedance in endurance athletes and explore its associations with traditional cardiovascular measurements. In 15 young male endurance runners and 19 young healthy men, time-resolved (CINE) two-dimensional (2-D) phase-contrast MRI quantified the ascending aortic flow while the pressure waveform was simultaneously collected via a generalized transfer function. The aortic impedance modulus and phase were calculated in the frequency domain while characteristic impedance (ZcF) was calculated by averaging moduli between the 4th and 8th heart rate (HR) harmonics. Stroke volume (SV), left ventricular (LV) morphometry, double product, aortic compliance, and total peripheral resistance (TPR) were also measured. Endurance athletes had higher SV, slower HR, greater LV end-diastolic volume and mass, and lower double product than sedentary participants (all P < 0.05). ZcF was significantly lower in athletes than in sedentary participants (73.3 ± 19.2 vs. 93.4 ± 19.0 dyn·s/cm5, P = 0.005). Furthermore, ZcF was negatively correlated with SV (r = -0.691) and aortic compliance (r = -0.601) but was positively correlated with double product (r = 0.445) and TPR (r = 0.458; all P < 0.05). Multivariate analysis revealed that ZcF was the strongest predictor of SV followed by TPR and HR (adjusted R2 = 0.788, P < 0.001). Therefore, our findings collectively suggest that LV afterload quantified by aortic ZcF is significantly lower in endurance athletes than in sedentary adults. The lower pulsatile LV afterload may contribute to greater SV in endurance athletes.NEW & NOTEWORTHY This is the first study to investigate aortic impedance with the noninvasive, simultaneous recordings of aortic pressure using SphygmoCor XCEL and flow using phase-contrast MRI. We found that the characteristic impedance (Zc) is significantly lower in endurance athletes than sedentary adults, is the strongest predictor of stroke volume (SV), and is inversely associated with aortic compliance. These findings suggest that aortic impedance is a key determinant of the ventricular-vascular coupling adapted to long-term training in endurance athletes.


Assuntos
Atletas , Função Ventricular Esquerda , Adulto , Humanos , Masculino , Impedância Elétrica , Função Ventricular Esquerda/fisiologia , Volume Sistólico/fisiologia , Imageamento por Ressonância Magnética , Resistência Física/fisiologia
7.
Med Image Anal ; 92: 103065, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38113616

RESUMO

4D flow MRI is an emerging imaging modality that maps voxel-wise blood flow information as velocity vector fields that is acquired in 7-dimensional image volumes (3 spatial dimensions + 3 velocity directions + time). Blood flow in the cardiovascular system is often complex and composite involving multiple flow dynamics and patterns (e.g., vortex flow, jets, stagnating flow) that occur and interact simultaneously. The spectrum of such complex flow dynamics is embedded in the velocity vector field dynamics derived from 4D Flow MRI. However, current flow metrics cannot fully measure high-dimensional vector-field data and embedded complex composite flow data. Instead, these methods need to break down the vector-field data into secondary scalar fields of individual flow components using fluid dynamics operators. These methods are gradient-based and sensitive to data uncertainties, and only focus on individual flow components of the overall composite flow, therefore potentially underestimating the severity of overall flow changes associated with cardiovascular diseases. To address these limitations, in MICCAI 2021, we introduced a novel comprehensive stochastic 4D Flow vector-field signature technique that works directly on the entire spatiotemporal velocity vector field. This technique uses efficient stochastic gradient-free interrogation of multi-million flow vector-pairs per patient to derive the patient's unique flow profile of the complex composite flow alterations and in real-time processing. The signature technique's probabilistic gradient-free formulation should allow for highly robust quantification despite inherent errors in 4D flow MRI acquisitions. Here, we extend the application of the 4D flow vector-field signature technique to the left atrium to analyze complex composite flow changes in patients with atrial fibrillation. In 128 subjects, we performed extensive sensitivity testing and determined that the vector-field signature technique is highly robust to typical sources of data uncertainties in 4D flow MRI: degradation in spatiotemporal resolution, added Gaussian noise, and segmentation errors. We demonstrate the excellent generalizability of the stochastic convergence from the aorta to the left atrium and between different 4D Flow MRI acquisition protocols. We compare the robustness of our technique to existing advanced flow quantification metrics of kinetic energy, vorticity, and energy loss demonstrating a superior performance of up-to 14-fold. Our results show the potential diagnostic and clinical utility of our signature technique in identifying distinctly altered composite flow signatures in atrial fibrillation patients independent of existing flow metrics.


Assuntos
Fibrilação Atrial , Humanos , Fibrilação Atrial/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Velocidade do Fluxo Sanguíneo/fisiologia , Imageamento Tridimensional/métodos , Átrios do Coração
8.
Radiol Med ; 128(10): 1225-1235, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37620674

RESUMO

PURPOSE: Four-dimensional time-resolved phase-contrast cardiovascular magnetic resonance imaging (4D flow MRI) enables blood flow quantification in multiple vessels, which is crucial for patients with congenital heart disease (CHD). We investigated net flow volumes in the ascending aorta and pulmonary arteries by four different postprocessing software packages for 4D flow MRI in comparison with 2D cine phase-contrast measurements (2D PC). MATERIAL AND METHODS: 4D flow and 2D PC datasets of 47 patients with biventricular CHD (median age 16, range 0.6-52 years) were acquired at 1.5 T. Net flow volumes in the ascending aorta, the main, right, and left pulmonary arteries were measured using four different postprocessing software applications and compared to offset-corrected 2D PC data. Reliability of 4D flow postprocessing software was assessed by Bland-Altman analysis and intraclass correlation coefficient (ICC). Linear regression of internal flow controls was calculated. Interobserver reproducibility was evaluated in 25 patients. RESULTS: Correlation and agreement of flow volumes were very good for all software compared to 2D PC (ICC ≥ 0.94; bias ≤ 5%). Internal controls were excellent for 2D PC (r ≥ 0.95, p < 0.001) and 4D flow (r ≥ 0.94, p < 0.001) without significant difference of correlation coefficients between methods. Interobserver reliability was good for all vendors (ICC ≥ 0.94, agreement bias < 8%). CONCLUSION: Haemodynamic information from 4D flow in the large thoracic arteries assessed by four commercially available postprocessing applications matches routinely performed 2D PC values. Therefore, we consider 4D flow MRI-derived data ready for clinical use in patients with CHD.


Assuntos
Cardiopatias Congênitas , Imageamento por Ressonância Magnética , Humanos , Lactente , Pré-Escolar , Criança , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Velocidade do Fluxo Sanguíneo/fisiologia , Aorta/diagnóstico por imagem , Software , Imageamento Tridimensional/métodos
9.
J Cardiovasc Magn Reson ; 25(1): 40, 2023 07 20.
Artigo em Inglês | MEDLINE | ID: mdl-37474977

RESUMO

Hemodynamic assessment is an integral part of the diagnosis and management of cardiovascular disease. Four-dimensional cardiovascular magnetic resonance flow imaging (4D Flow CMR) allows comprehensive and accurate assessment of flow in a single acquisition. This consensus paper is an update from the 2015 '4D Flow CMR Consensus Statement'. We elaborate on 4D Flow CMR sequence options and imaging considerations. The document aims to assist centers starting out with 4D Flow CMR of the heart and great vessels with advice on acquisition parameters, post-processing workflows and integration into clinical practice. Furthermore, we define minimum quality assurance and validation standards for clinical centers. We also address the challenges faced in quality assurance and validation in the research setting. We also include a checklist for recommended publication standards, specifically for 4D Flow CMR. Finally, we discuss the current limitations and the future of 4D Flow CMR. This updated consensus paper will further facilitate widespread adoption of 4D Flow CMR in the clinical workflow across the globe and aid consistently high-quality publication standards.


Assuntos
Sistema Cardiovascular , Humanos , Velocidade do Fluxo Sanguíneo , Valor Preditivo dos Testes , Coração , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética
10.
Magn Reson Imaging Clin N Am ; 31(3): 433-449, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37414470

RESUMO

4D Flow MRI is an advanced imaging technique for comprehensive non-invasive assessment of the cardiovascular system. The capture of the blood velocity vector field throughout the cardiac cycle enables measures of flow, pulse wave velocity, kinetic energy, wall shear stress, and more. Advances in hardware, MRI data acquisition and reconstruction methodology allow for clinically feasible scan times. The availability of 4D Flow analysis packages allows for more widespread use in research and the clinic and will facilitate much needed multi-center, multi-vendor studies in order to establish consistency across scanner platforms and to enable larger scale studies to demonstrate clinical value.


Assuntos
Imageamento por Ressonância Magnética , Análise de Onda de Pulso , Humanos , Imageamento por Ressonância Magnética/métodos , Velocidade do Fluxo Sanguíneo , Coração , Imageamento Tridimensional
11.
J Cardiovasc Magn Reson ; 25(1): 22, 2023 03 28.
Artigo em Inglês | MEDLINE | ID: mdl-36978131

RESUMO

BACKGROUND: Different software programs are available for the evaluation of 4D Flow cardiovascular magnetic resonance (CMR). A good agreement of the results between programs is a prerequisite for the acceptance of the method. Therefore, the goal was to compare quantitative results from a cross-over comparison in individuals examined on two scanners of different vendors analyzed with four postprocessing software packages. METHODS: Eight healthy subjects (27 ± 3 years, 3 women) were each examined on two 3T CMR systems (Ingenia, Philips Healthcare; MAGNETOM Skyra, Siemens Healthineers) with a standardized 4D Flow CMR sequence. Six manually placed aortic contours were evaluated with Caas (Pie Medical Imaging, SW-A), cvi42 (Circle Cardiovascular Imaging, SW-B), GTFlow (GyroTools, SW-C), and MevisFlow (Fraunhofer Institute MEVIS, SW-D) to analyze seven clinically used parameters including stroke volume, peak flow, peak velocity, and area as well as typically scientifically used wall shear stress values. Statistical analysis of inter- and intrareader variability, inter-software and inter-scanner comparison included calculation of absolute and relative error (ER), intraclass correlation coefficient (ICC), Bland-Altman analysis, and equivalence testing based on the assumption that inter-software differences needed to be within 80% of the range of intrareader differences. RESULTS: SW-A and SW-C were the only software programs showing agreement for stroke volume (ICC = 0.96; ER = 3 ± 8%), peak flow (ICC: 0.97; ER = -1 ± 7%), and area (ICC = 0.81; ER = 2 ± 22%). Results from SW-A/D and SW-C/D were equivalent only for area and peak flow. Other software pairs did not yield equivalent results for routinely used clinical parameters. Especially peak maximum velocity yielded poor agreement (ICC ≤ 0.4) between all software packages except SW-A/D that showed good agreement (ICC = 0.80). Inter- and intrareader consistency for clinically used parameters was best for SW-A and SW-D (ICC = 0.56-97) and worst for SW-B (ICC = -0.01-0.71). Of note, inter-scanner differences per individual tended to be smaller than inter-software differences. CONCLUSIONS: Of all tested software programs, only SW-A and SW-C can be used equivalently for determination of stroke volume, peak flow, and vessel area. Irrespective of the applied software and scanner, high intra- and interreader variability for all parameters have to be taken into account before introducing 4D Flow CMR in clinical routine. Especially in multicenter clinical trials a single image evaluation software should be applied.


Assuntos
Imageamento por Ressonância Magnética , Software , Humanos , Feminino , Reprodutibilidade dos Testes , Valor Preditivo dos Testes , Aorta
12.
Med Sci (Basel) ; 11(1)2023 01 24.
Artigo em Inglês | MEDLINE | ID: mdl-36810480

RESUMO

There remains a debate whether the ventricular volume within prolapsing mitral valve (MV) leaflets should be included in the left ventricular (LV) end-systolic volume, and therefore factored in LV stroke volume (SV), in cardiac magnetic resonance (CMR) assessments. This study aims to compare LV volumes during end-systolic phases, with and without the inclusion of the volume of blood on the left atrial aspect of the atrioventricular groove but still within the MV prolapsing leaflets, against the reference LV SV by four-dimensional flow (4DF). A total of 15 patients with MV prolapse (MVP) were retrospectively enrolled in this study. We compared LV SV with (LV SVMVP) and without (LV SVstandard) MVP left ventricular doming volume, using 4D flow (LV SV4DF) as the reference value. Significant differences were observed when comparing LV SVstandard and LV SVMVP (p < 0.001), and between LV SVstandard and LV SV4DF (p = 0.02). The Intraclass Correlation Coefficient (ICC) test demonstrated good repeatability between LV SVMVP and LV SV4DF (ICC = 0.86, p < 0.001) but only moderate repeatability between LV SVstandard and LV SV4DF (ICC = 0.75, p < 0.01). Calculating LV SV by including the MVP left ventricular doming volume has a higher consistency with LV SV derived from the 4DF assessment. In conclusion, LV SV short-axis cine assessment incorporating MVP dooming volume can significantly improve the precision of LV SV assessment compared to the reference 4DF method. Hence, in cases with bi-leaflet MVP, we recommend factoring in MVP dooming into the left ventricular end-systolic volume to improve the accuracy and precision of quantifying mitral regurgitation.


Assuntos
Prolapso da Valva Mitral , Humanos , Prolapso da Valva Mitral/patologia , Volume Sistólico , Estudos Retrospectivos , Função Ventricular Esquerda , Imageamento por Ressonância Magnética
13.
J Cardiovasc Magn Reson ; 25(1): 9, 2023 02 13.
Artigo em Inglês | MEDLINE | ID: mdl-36775827

RESUMO

BACKGROUND: Four-dimensional (4D) flow cardiovascular magnetic resonance (CMR) is feasible for portal blood flow evaluation after placement of transjugular intrahepatic portosystemic shunts (TIPS) in patients with liver cirrhosis. However, clinical acceptance of 4D flow CMR in TIPS patients is limited due to the lack of validation studies. The purpose of this study was to validate 4D flow CMR-derived measurements in TIPS stent grafts using a three-dimensional (3D)-printed flow phantom. METHODS: A translucent flow phantom of the portal vasculature was 3D-printed. The phantom consisted of the superior mesenteric vein and the splenic vein draining into the portal vein, the TIPS-tract, and the hepatic vein. A TIPS stent graft (Gore® Viatorr®) was positioned within the TIPS-tract. Superior mesenteric vein and splenic vein served as inlets for blood-mimicking fluid. 4D flow CMR acquisitions were performed at 3T at preset flow rates of 0.8 to 2.8 l/min using velocity encoding of both 1.0 and 2.0 m/s. Flow rates and velocities were measured at predefined levels in the portal vasculature and within the stent graft. Accuracy of 4D flow CMR was assessed through linear regression with reference measurements obtained by flow sensors and two-dimensional (2D) phase contrast (PC) CMR. Intra- and interobserver agreement were assessed through Bland-Altman analyses. RESULTS: At a velocity encoding of 2.0 m/s, 4D flow CMR-derived flow rates and velocities showed an excellent correlation with preset flow rates and 2D PC CMR-derived flow velocities at all vascular levels and within the stent graft (all r ≥ 0.958, p ≤ 0.003). At a velocity encoding of 1.0 m/s, aliasing artifacts were present within the stent graft at flow rates ≥ 2.0 l/min. 4D flow CMR-derived measurements revealed high intra- and interobserver agreement. CONCLUSIONS: The in vitro accuracy and precision of 4D flow CMR is unaffected by the presence of TIPS stent grafts, suggesting that 4D flow CMR may be used to monitor TIPS patency in patients with liver cirrhosis.


Assuntos
Cirrose Hepática , Stents , Humanos , Valor Preditivo dos Testes , Espectroscopia de Ressonância Magnética , Impressão Tridimensional
14.
J Cardiovasc Dev Dis ; 9(9)2022 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-36135449

RESUMO

There is increasing recognition of the value of four-dimensional flow cardiovascular magnetic resonance (4D-flow MRI) as a potential means to detect and measure abnormal flow behaviour that occurs during early left ventricular (LV) dysfunction. We performed a systematic review of current literature on the role of 4D-flow MRI-derived flow parameters in quantification of LV function with a focus on potential clinical applicability. A comprehensive literature search was performed in March 2022 on available databases. A total of 1186 articles were identified, and 30 articles were included in the final analysis. All the included studies were ranked as "highly clinically applicable". There was considerable variability in the reporting of methodologies and analyses. All the studies were small-scale feasibility or pilot studies investigating a diverse range of flow parameters. The most common primary topics of investigation were energy-related flow parameters, flow components and vortex analysis which demonstrated potentials for quantifying early diastolic dysfunction, whilst other parameters including haemodynamic forces, residence time distribution and turbulent kinetic energy remain in need of further evaluation. Systematic quantitative comparison of study findings was not possible due to this heterogeneity, therefore limiting the collective power of the studies in evaluating clinical applicability of the flow parameters. To achieve broader clinical application of 4D-flow MRI, larger scale investigations are required, together with standardisation of methodologies and analytical approach.

15.
Front Artif Intell ; 5: 928181, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36034591

RESUMO

Exploiting 4D-flow magnetic resonance imaging (MRI) data to quantify hemodynamics requires an adequate spatio-temporal vector field resolution at a low noise level. To address this challenge, we provide a learned solution to super-resolve in vivo 4D-flow MRI data at a post-processing level. We propose a deep convolutional neural network (CNN) that learns the inter-scale relationship of the velocity vector map and leverages an efficient residual learning scheme to make it computationally feasible. A novel, direction-sensitive, and robust loss function is crucial to learning vector-field data. We present a detailed comparative study between the proposed super-resolution and the conventional cubic B-spline based vector-field super-resolution. Our method improves the peak-velocity to noise ratio of the flow field by 10 and 30% for in vivo cardiovascular and cerebrovascular data, respectively, for 4 × super-resolution over the state-of-the-art cubic B-spline. Significantly, our method offers 10x faster inference over the cubic B-spline. The proposed approach for super-resolution of 4D-flow data would potentially improve the subsequent calculation of hemodynamic quantities.

16.
Magn Reson Med ; 88(6): 2709-2717, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35916368

RESUMO

PURPOSE: Flow quantification by phase-contrast MRI is hampered by spatially varying background phase offsets. Correction performance by polynomial regression on stationary tissue may be affected by outliers such as wrap-around or constant flow. Therefore, we propose an alternative, M-estimate SAmple Consensus (MSAC) to reject outliers, and improve and fully automate background phase correction. METHODS: The MSAC technique fits polynomials to randomly drawn small samples from the image. Over several trials, it aims to find the best consensus set of valid pixels by rejecting outliers to the fit and minimizing the residuals of the remaining pixels. The robustness of MSAC to its few parameters was investigated and verified using third-order polynomial correction fits on a total of 118 2D flow (97 with wrap-around) and 18 4D flow data sets (14 with wrap-around), acquired at 1.5 T and 3 T. Background phase was compared with standard stationary correction and phantom correction. Pulmonary/systemic flow ratios in 2D flow were derived, and exemplary 4D flow analysis was performed. RESULTS: The MSAC technique is robust over a range of parameter choices, and a unique set of parameters is suitable for both 2D and 4D flow. In 2D flow, phase errors were significantly reduced by MSAC compared with stationary correction (p = 0.005), and stationary correction shows larger errors in pulmonary/systemic flow ratios compared with MSAC. In 4D flow, MSAC shows similar performance as stationary correction. CONCLUSIONS: The MSAC method provides fully automated background phase correction to 2D and 4D flow data and shows improved robustness over stationary correction, especially with outliers present.


Assuntos
Algoritmos , Imageamento por Ressonância Magnética , Velocidade do Fluxo Sanguíneo , Consenso , Voluntários Saudáveis , Humanos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Reprodutibilidade dos Testes
17.
Sensors (Basel) ; 23(1)2022 Dec 30.
Artigo em Inglês | MEDLINE | ID: mdl-36617006

RESUMO

The biomechanical properties of blood have been used to detect haematological diseases and disorders. The simultaneous measurement of multiple haemorheological properties has been considered an important aspect for separating the individual contributions of red blood cells (RBCs) and plasma. In this study, three haemorheological properties (viscosity, time constant, and RBC aggregation) were obtained by analysing blood flow, which was set to a square-wave profile (steady and transient flow). Based on a simplified differential equation derived using a discrete circuit model, the time constant for viscoelasticity was obtained by solving the governing equation rather than using the curve-fitting technique. The time constant (λ) varies linearly with respect to the interface in the coflowing channel (ß). Two parameters (i.e., average value: <λ>, linear slope: dλdß) were newly suggested to effectively represent linearly varying time constant. <λ> exhibited more consistent results than dλdß. To detect variations in the haematocrit in blood, we observed that the blood viscosity (i.e., steady flow) is better than the time constant (i.e., transient flow). The blood viscosity and time constant exhibited significant differences for the hardened RBCs. The present method was then successfully employed to detect continuously varying haematocrit resulting from RBC sedimentation in a driving syringe. The present method can consistently detect variations in blood in terms of the three haemorheological properties.


Assuntos
Viscosidade Sanguínea , Agregação Eritrocítica , Viscosidade Sanguínea/fisiologia , Agregação Eritrocítica/fisiologia , Hematócrito , Eritrócitos , Hemodinâmica
18.
J Magn Reson Imaging ; 56(3): 768-778, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-34854151

RESUMO

BACKGROUND: Four-dimensional (4D) flow cardiac magnetic resonance (cardiac MR) imaging provides quantification of intracavity left ventricular (LV) flow kinetic energy (KE) parameters in three dimensions. ST-elevation myocardial infarction (STEMI) patients have been shown to have altered intracardiac blood flow compared to controls; however, how 4D flow parameters change over time has not been explored previously. PURPOSE: Measure longitudinal changes in intraventricular flow post-STEMI and ascertain its predictive relevance of long-term cardiac remodeling. STUDY TYPE: Prospective. POPULATION: Thirty-five STEMI patients (M:F = 26:9, aged 56 ± 9 years). FIELD STRENGTH/SEQUENCE: A 3 T/3D EPI-based, fast field echo (FFE) free-breathing 4D-flow sequence with retrospective cardiac gating. ASSESSMENT: Serial imaging at 3-7 days (V1), 3-months (V2), and 12-months (V3) post-STEMI, including the following protocol: functional imaging for measuring volumes and 4D-flow for calculating parameters including systolic and peakE-wave LVKE, normalized to end-diastolic volume (iEDV) and stroke volume (iSV). Data were analyzed by H.B. (3 years experience). Patients were categorized into two groups: preserved ejection fraction (pEF, if EF > 50%) and reduced EF (rEF, if EF < 50%). STATISTICAL TESTS: Independent sample t-tests were used to detect the statistical significance between any two cohorts. P < 0.05 was considered statistically significant. RESULTS: Across the cohort, systolic KEisv was highest at V1 (28.0 ± 4.4 µJ/mL). Patients with rEF retained significantly higher systolic KEisv than patients with pEF at V2 (18.2 ± 3.4 µJ/mL vs. 6.9 ± 0.6 µJ/mL, P < 0.001) and V3 (21.6 ± 5.1 µJ/mL vs. 7.4 ± 0.9 µJ/mL, P < 0.001). Patients with pEF had significantly higher peakE-wave KEiEDV than rEF patients throughout the study (V1: 25.4 ± 11.6 µJ/mL vs. 18.1 ± 9.9 µJ/mL, P < 0.03, V2: 24.0 ± 10.2 µJ/mL vs. 17.2 ± 12.2 µJ/mL, P < 0.05, V3: 27.7 ± 14.8 µJ/mL vs. 15.8 ± 7.6 µJ/mL, P < 0.04). DATA CONCLUSION: Systolic KE increased acutely following MI; in patients with pEF, this decreased over 12 months, while patients with rEF, this remained raised. Compared to patients with pEF, persistently lower peakE-wave KE in rEF patients is suggestive of early and fixed impairment in diastolic function. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 3.


Assuntos
Infarto do Miocárdio , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Infarto do Miocárdio/diagnóstico por imagem , Estudos Prospectivos , Estudos Retrospectivos , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Volume Sistólico , Função Ventricular Esquerda , Remodelação Ventricular
19.
J Cereb Blood Flow Metab ; 42(2): 292-302, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34550818

RESUMO

Residual blood flow distal to an arterial occlusion in patients with acute ischemic stroke (AIS) is associated with favorable patient outcome. Both collateral flow and thrombus permeability may contribute to such residual flow. We propose a method for discriminating between these two mechanisms, based on determining the direction of flow in multiple branches distal to the occluding thrombus using dynamic Computed Tomography Angiography (dynamic CTA). We analyzed dynamic CTA data of 30 AIS patients and present patient-specific cases that identify typical blood flow patterns and velocities. We distinguished patterns with anterograde (N = 10), retrograde (N = 9), and both flow directions (N = 11), with a large variability in velocities for each flow pattern. The observed flow patterns reflect the interplay between permeability and collaterals. The presented method characterizes distal flow and provides a tool to study patient-specific distal tissue perfusion.


Assuntos
Angiografia Cerebral , Artérias Cerebrais , Circulação Colateral , Angiografia por Tomografia Computadorizada , AVC Isquêmico , Idoso , Velocidade do Fluxo Sanguíneo , Artérias Cerebrais/diagnóstico por imagem , Artérias Cerebrais/fisiopatologia , Humanos , AVC Isquêmico/diagnóstico por imagem , AVC Isquêmico/fisiopatologia , Masculino , Pessoa de Meia-Idade
20.
Front Bioeng Biotechnol ; 9: 725833, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34869250

RESUMO

Magnetic resonance imaging (MRI) can potentially be used for non-invasive screening of patients with stable angina pectoris to identify probable obstructive coronary artery disease. MRI-based coronary blood flow quantification has to date only been performed in a 2D fashion, limiting its clinical applicability. In this study, we propose a framework for coronary blood flow quantification using accelerated 4D flow MRI with respiratory motion correction and compressed sensing image reconstruction. We investigate its feasibility and repeatability in healthy subjects at rest. Fourteen healthy subjects received 8 times-accelerated 4D flow MRI covering the left coronary artery (LCA) with an isotropic spatial resolution of 1.0 mm3. Respiratory motion correction was performed based on 1) lung-liver navigator signal, 2) real-time monitoring of foot-head motion of the liver and LCA by a separate acquisition, and 3) rigid image registration to correct for anterior-posterior motion. Time-averaged diastolic LCA flow was determined, as well as time-averaged diastolic maximal velocity (VMAX) and diastolic peak velocity (VPEAK). 2D flow MRI scans of the LCA were acquired for reference. Scan-rescan repeatability and agreement between 4D flow MRI and 2D flow MRI were assessed in terms of concordance correlation coefficient (CCC) and coefficient of variation (CV). The protocol resulted in good visibility of the LCA in 11 out of 14 subjects (six female, five male, aged 28 ± 4 years). The other 3 subjects were excluded from analysis. Time-averaged diastolic LCA flow measured by 4D flow MRI was 1.30 ± 0.39 ml/s and demonstrated good scan-rescan repeatability (CCC/CV = 0.79/20.4%). Time-averaged diastolic VMAX (17.2 ± 3.0 cm/s) and diastolic VPEAK (24.4 ± 6.5 cm/s) demonstrated moderate repeatability (CCC/CV = 0.52/19.0% and 0.68/23.0%, respectively). 4D flow- and 2D flow-based diastolic LCA flow agreed well (CCC/CV = 0.75/20.1%). Agreement between 4D flow MRI and 2D flow MRI was moderate for both diastolic VMAX and VPEAK (CCC/CV = 0.68/20.3% and 0.53/27.0%, respectively). In conclusion, the proposed framework of accelerated 4D flow MRI equipped with respiratory motion correction and compressed sensing image reconstruction enables repeatable diastolic LCA flow quantification that agrees well with 2D flow MRI.