Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
Expert Rev Respir Med ; 15(6): 773-779, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33798401

RESUMO

Introduction: Bronchoscopy and related procedures have unambiguously been affected during the Corona Virus Disease 2019 (COVID-19) pandemic caused by Severe Acute Respiratory Syndrome-Corona Virus-2 (SARS COV-2). Ordinary bronchoscopy practices and lung cancer services might have changed over this pandemic and for the years to come.Areas covered: This manuscript summarizes the utility of bronchoscopy in COVID-19 patients, and the impact of the pandemic in lung cancer diagnostic services, in view of possible viral spread during these We conducted a literature review of articles published in PubMed/Medline from inception to November 5th, 2020 using relevant terms.Expert opinion: Without doubt this pandemic has changed the way bronchoscopy and related procedures are being performed. Mandatory universal personal protective equipment, pre-bronchoscopy PCR tests, dedicated protective barriers and disposable bronchoscopes might be the safest and simpler way to perform even the most complicated procedures.


Assuntos
Broncoscopia , COVID-19/epidemiologia , COVID-19/terapia , Infecção Hospitalar/prevenção & controle , Padrões de Prática Médica , Broncoscópios/microbiologia , Broncoscópios/normas , Broncoscópios/virologia , Broncoscopia/instrumentação , Broncoscopia/métodos , Broncoscopia/normas , COVID-19/prevenção & controle , COVID-19/transmissão , Contaminação de Equipamentos/prevenção & controle , História do Século XXI , Humanos , Neoplasias Pulmonares/diagnóstico , Oncologia/instrumentação , Oncologia/métodos , Oncologia/normas , Pandemias , Equipamento de Proteção Individual/virologia , Padrões de Prática Médica/normas , Padrões de Prática Médica/tendências , SARS-CoV-2/fisiologia
3.
Medicina (Kaunas) ; 56(7)2020 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-32630648

RESUMO

Background and objectives: Persistent wheezing (PW) is defined as prolonged or recurrent episodes of wheezing despite regular treatment. Flexible bronchoscopy (FB) is recommended to determine the etiology of PW in children. This study aimed to determine the etiology of PW based on FB findings in a national pediatric center. Materials and Methods: Children presenting with PW that underwent flexible bronchoscopy from April 2016 to August 2019 at the Mother and Child Health Institute of Serbia were included in this observational study. After endoscopic evaluation, bronchoalveolar lavage fluid (BALF) samples were taken and further analyzed. Quantitative microbiology, cytological analysis and oil-red staining of specimens were performed to determine cellular constituents and presence of lipid laden macrophages (LLM). Upper gastrointestinal series were performed to exclude gastroesophageal reflux disease, swallowing dysfunction and vascular ring. Results: Pathological findings were revealed in 151 of 172 study participants, with bacterial lower airway infection (BLAI) (48.3%) and primary bronchomalacia (20.4%) as the most common. Younger participants were hospitalized for significantly longer periods (ρ = -0.366, p < 0.001). Study participants with BLAI and associated mucus plugging were notably younger (p < 0.001). Presence of LLM in BALF was not associated with findings of upper gastrointestinal series. All patients with confirmed BLAI were treated with oral antibiotics. Although FB is considered to be invasive, there were no complications associated with the procedure. Conclusions: Flexible bronchoscopy has an exceptional diagnostic value in evaluation of PW. In younger patients with BLAI, presence of mucus plugs may complicate the clinical course, so significant benefits can be achieved with therapeutic lavage during bronchoscopy.


Assuntos
Broncoscópios/normas , Broncoscopia/instrumentação , Broncoscopia/métodos , Sons Respiratórios/diagnóstico , Sons Respiratórios/fisiopatologia , Adolescente , Lavagem Broncoalveolar/instrumentação , Lavagem Broncoalveolar/métodos , Broncoscopia/normas , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Estudos Retrospectivos , Sérvia
4.
Biomed Res Int ; 2020: 1091239, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32337218

RESUMO

BACKGROUND: This study was aimed at investigating the effectiveness of the implementation of a comprehensive quality improvement programme (QIP) for reducing the repair rate of the fibreoptic bronchoscope (FOB). METHODS: A three-stage improvement strategy was implemented between January 2013 and December 2016. Stage one is the acquisition of information on violations of practice guidelines, repair rate, cost of repair, and incidence of unavailability of FOB during anaesthesia induction of the previous year through auditing. Stage two is the implementation of a quality improvement campaign (QIC) based on the results of stage one. Stage three is the programme perpetuation through monitoring compliance with policy on FOB use by regular internal audits. The effectiveness was retrospectively analyzed on a yearly basis. RESULTS: The annual repair rate, repair cost, and incidence of FOB unavailability before the QIP implementation were 1%, 18,757 USD, and 1.4%, respectively. After QIC, the repair rate in 2013 dropped by 81% (from 1% in 2012 to 0.19% in 2013, p < 0.05). The annual repair cost fell by 32% from 18,758 USD (2012) to 12,820 USD (2013). Besides, the incidence of FOB unavailability plummeted by 71% from 1.4% to 0.4% during the same period. The annual repair rates and incidence of FOB unavailability remained lower in subsequent three years than those before QIP implementation. CONCLUSION: Implementation of a quality improvement programme was effective for reducing the rate and cost of FOB repair as well as unavailability rate, highlighting its beneficial impact on cost-effectiveness and patient safety in a tertiary referral center setting.


Assuntos
Broncoscópios , Falha de Equipamento/economia , Manutenção , Melhoria de Qualidade , Anestesia Endotraqueal/instrumentação , Broncoscópios/efeitos adversos , Broncoscópios/economia , Broncoscópios/normas , Broncoscópios/estatística & dados numéricos , Broncoscopia/instrumentação , Análise Custo-Benefício , Tecnologia de Fibra Óptica , Humanos , Manutenção/economia , Manutenção/métodos , Manutenção/normas , Manutenção/estatística & dados numéricos , Segurança do Paciente , Estudos Retrospectivos
6.
Chest ; 154(5): 1024-1034, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-29859183

RESUMO

BACKGROUND: Infections have been linked to inadequately reprocessed flexible bronchoscopes, and recent investigations determined that pathogen transmission occurred even when bronchoscope cleaning and disinfection practices aligned with current guidelines. This multisite, prospective study evaluated the effectiveness of real-world bronchoscope reprocessing methods, using a systematic approach. METHODS: This study involved direct observation of reprocessing methods for flexible bronchoscopes, multifaceted evaluations performed after manual cleaning and after high-level disinfection, and assessments of storage conditions. Visual inspections of ports and channels were performed using lighted magnification and borescopes. Contamination was detected using microbial cultures and tests for protein, hemoglobin, and adenosine triphosphate (ATP). Researchers assessed reprocessing practices, and storage cabinet cleanliness was evaluated by visual inspection and ATP tests. RESULTS: Researchers examined 24 clinically used bronchoscopes. After manual cleaning, 100% of bronchoscopes had residual contamination. Microbial growth was found in 14 fully reprocessed bronchoscopes (58%), including mold, Stenotrophomonas maltophilia, and Escherichia coli/Shigella species. Visible irregularities were observed in 100% of bronchoscopes, including retained fluid; brown, red, or oily residue; scratches; damaged insertion tubes and distal ends; and filamentous debris in channels. Reprocessing practices were substandard at two of three sites. CONCLUSIONS: Damaged and contaminated bronchoscopes were in use at all sites. Inadequate reprocessing practices may have contributed to bioburden found on bronchoscopes. However, even when guidelines were followed, high-level disinfection was not effective. A shift toward the use of sterilized bronchoscopes is recommended. In the meantime, quality management programs and updated reprocessing guidelines are needed.


Assuntos
Bactérias , Broncoscópios , Desinfecção/métodos , Reutilização de Equipamento/normas , Esterilização/métodos , Ultrassonografia de Intervenção/instrumentação , Bactérias/classificação , Bactérias/isolamento & purificação , Broncoscópios/microbiologia , Broncoscópios/normas , Contaminação de Equipamentos/prevenção & controle , Humanos , Controle de Infecções/métodos , Técnicas Microbiológicas/métodos , Guias de Prática Clínica como Assunto , Estudos Prospectivos , Melhoria de Qualidade
8.
Anesth Analg ; 126(5): 1575-1579, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-28858897

RESUMO

Bronchial thermoplasty (BT) is a novel, Food and Drug Administration-approved nondrug treatment for patients whose asthma remains uncontrolled despite traditional pharmacotherapy. BT involves application of controlled radiofrequency energy to reduce airway smooth muscle in large- and medium-sized airways. Although BT is often performed under general anesthesia, anesthetic management strategies for BT are poorly described. We describe the anesthetic management of 7 patients who underwent 19 BT treatments in a tertiary academic medical center.


Assuntos
Manuseio das Vias Aéreas/métodos , Anestesia Intravenosa/métodos , Anestésicos Intravenosos/administração & dosagem , Asma/terapia , Termoplastia Brônquica/métodos , Adulto , Idoso , Manuseio das Vias Aéreas/instrumentação , Manuseio das Vias Aéreas/normas , Anestesia Intravenosa/normas , Asma/diagnóstico , Termoplastia Brônquica/instrumentação , Termoplastia Brônquica/normas , Broncoscópios/normas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Músculo Liso/efeitos dos fármacos , Músculo Liso/fisiologia , Estudos Retrospectivos
10.
Intern Emerg Med ; 12(5): 667-673, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27637970

RESUMO

A difficult airway may lead to hypoxia and brain damage. The WEI Nasal Jet Tube (WNJ) is a new nasal pharyngeal tube that applies supraglottic jet oxygenation and ventilation (SJOV) for patients during tracheal intubation without the need for mask ventilation. We evaluated the effectiveness and safety of SJOV-assisted fibre-optic bronchoscopy (FOB) using the WNJ in the management of difficult tracheal intubations. A total of 50 adult patients with Cormack-Lehane grade ≥3 and general anesthesia with tracheal intubation were randomly assigned to either the laryngeal mask airway (LMA) or WNJ groups. The primary outcome was the percentage of patients with SpO2 values lower than 94 % during intubation. The proportion of successful intubations, total time of intubation, and associated complications were also recorded. The percentage of patients with SpO2 values lower than 94 % during intubation was significantly higher in the LMA group (25 % in the LMA vs. 0 % in the WNJ, P = 0.01). Although there were no statistically significant differences in the total success rates of intubation, the first-attempt success rate was significantly higher in the WNJ group (100 vs. 79.2 %, P = 0.02). The total time required for intubation with the WNJ was shorter than that of the LMA (73.4 vs. 99.5 s, P < 0.001), although the duration of fibre-optic intubation was similar. The incidence of complications was similar between the two groups. SJOV-assisted FOB using the WNJ improved oxygenation and successful tracheal intubation in the management of difficult airways. This technique can be used as an alternative approach to improve success and minimize hypoxia during difficult airway management.


Assuntos
Manuseio das Vias Aéreas/normas , Broncoscópios/normas , Ventilação em Jatos de Alta Frequência/normas , Intubação Intratraqueal/métodos , Adulto , Manuseio das Vias Aéreas/métodos , Manuseio das Vias Aéreas/estatística & dados numéricos , Broncoscópios/estatística & dados numéricos , China , Desenho de Equipamento/normas , Feminino , Ventilação em Jatos de Alta Frequência/métodos , Ventilação em Jatos de Alta Frequência/estatística & dados numéricos , Humanos , Intubação Intratraqueal/instrumentação , Intubação Intratraqueal/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Projetos Piloto
11.
Lijec Vjesn ; 138(1-2): 34-8, 2016.
Artigo em Servo-Croata (Latino) | MEDLINE | ID: mdl-27290812

RESUMO

Endobronchial ultrasound (EBUS) enables visualization of mediastinal and hilar lymph nodes as well as, in case of clinical indication, its transbronchial needle aspiration (TBNA). Simultaneous application of color doppler gives the additional prospects to investigate the blood vessels. The primary indication for EBUS is radiographic finding of mediastinal and/or hilar lymph nodes enlargement as well as the staging of non-small cell lung cancer (NSCLC). In this article we present the initial results of application of this valuable diagnostic procedure performed at the Department for pulmonary diseases in Clinical hospital Dubrava in Zagreb. According to its high sensitivity and specificity, and being safe and well tolerated, EBUS-TBNA was positioned as basic diagnostic procedure in patients with mediastinal lymphadenopathy.


Assuntos
Broncoscopia , Carcinoma Pulmonar de Células não Pequenas/patologia , Endossonografia , Neoplasias Pulmonares/patologia , Doenças Linfáticas/diagnóstico , Mediastino , Adulto , Idoso , Biópsia por Agulha/instrumentação , Biópsia por Agulha/métodos , Broncoscópios/normas , Broncoscopia/instrumentação , Broncoscopia/métodos , Croácia , Endossonografia/instrumentação , Endossonografia/métodos , Feminino , Hospitais/estatística & dados numéricos , Humanos , Linfonodos/diagnóstico por imagem , Masculino , Mediastino/diagnóstico por imagem , Mediastino/patologia , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
12.
Anaesth Intensive Care ; 42(5): 657-64, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25233181

RESUMO

The importance of appropriate equipment to manage the difficult airway has been highlighted by the publication of the Australian and New Zealand College of Anaesthetists (ANZCA) guidelines in 2012. We set out to audit compliance with these guidelines in all public and private sites providing general anaesthesia in metropolitan Perth. Public and private health care websites identified 39 sites of which 37 were studied. Institutional and ethics approval was obtained. A tick-box design audit tool, based on the ANZCA guidelines, was used to collect information regarding the dedicated difficult airway container (DDAC) at each site. As recommended in the guidelines, only equipment within the DDAC was considered. Further data about each site, including the number of theatre suites, satellite anaesthetic areas, use of capnography and categories of patients treated (adult, obstetric and paediatric) were collected. An adult DDAC was found at 92% of all sites, but none of the sites had all the essential equipment listed in the ANZCA guidelines. There was limited provision of adult difficult airway equipment within private sites compared to public, and less provision of paediatric difficult airway equipment across all sites treating paediatric patients in metropolitan Perth. Capnography was available in 76% of post anaesthesia care units and used regularly in 27%. Adherence to the ANZCA guidelines regarding the DDAC could be improved. Standardised equipment across a metropolitan region would be of value in the management of the difficult airway.


Assuntos
Manuseio das Vias Aéreas/instrumentação , Adulto , Anestesia , Austrália , Broncoscópios/normas , Capnografia/normas , Criança , Humanos , Auditoria Médica , Garantia da Qualidade dos Cuidados de Saúde
13.
Anaesthesia ; 69(7): 701-6, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24773281

RESUMO

A single-use flexible bronchoscope with a large suction channel has become available recently and we have evaluated this innovative device. Firstly, bronchoalveolar lavage was performed and quantified in ventilated piglets. Next, the bronchoscope was evaluated in three intensive care units and a satisfaction questionnaire was carried out. Sixteen bronchoalveolar lavages were performed in piglets with a recovery rate of 83 (79-86 [72-89])% of the instilled volume. Quality and performance of all devices tested was identical. The medical satisfaction questionnaire was as follows: 'acceptable' to 'very good' for quality of aspiration, manoeuvrability and quality of vision; 'very good' to 'perfect' for setting up and insertion. This encouraging preliminary evaluation demonstrates the effectiveness of this new single-use device, which may obviate the need for disinfection procedures and, thereby, eradicate a potential vector of patient cross-contamination.


Assuntos
Lavagem Broncoalveolar/instrumentação , Lavagem Broncoalveolar/métodos , Broncoscópios/normas , Broncoscopia/instrumentação , Respiração Artificial , Animais , Broncoscopia/normas , Desenho de Equipamento , Reprodutibilidade dos Testes , Sucção , Inquéritos e Questionários , Suínos
14.
BMC Anesthesiol ; 14: 10, 2014 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-24575885

RESUMO

BACKGROUND: Smart phone technology is becoming increasingly integrated into medical care.Our study compared an iPhone modified flexible fibreoptic bronchoscope as an intubation aid and clinical teaching tool with an unmodified bronchoscope, Glidescope® and Macintosh laryngoscope in a simulated normal and difficult airway scenario. METHODS: Sixty three anaesthesia providers, 21 consultant anaesthetists, 21 registrars and 21 anaesthetic nurses attempted to intubate a MegaCode Kelly™ manikin, comparing a normal and difficult airway scenario for each device. Primary endpoints were time to view the vocal cords (TVC), time to successful intubation (TSI) and number of failed intubations with each device. Secondary outcomes included participant rated device usability and preference for each scenario. Advantages and disadvantages of the iPhone modified bronchoscope were also discussed. RESULTS: There was no significant difference in TVC with the iPhone modified bronchoscope compared with the Macintosh blade (P = 1.0) or unmodified bronchoscope (P = 0.155). TVC was significantly shorter with the Glidescope compared with the Macintosh blade (P < 0.001), iPhone (P < 0.001) and unmodified bronchoscope (P = 0.011). The iPhone bronchoscope TSI was significantly longer than all other devices (P < 0.001). There was no difference between anaesthetic consultant or registrar TVC (P = 1.0) or TSI (P = 0.252), with both being less than the nurses (P < 0.001). Consultant anaesthetists and nurses had a higher intubation failure rate with the iPhone modified bronchoscope compared with the registrars. Although more difficult to use, similar proportions of consultants (14/21), registrars (15/21) and nurses (15/21) indicated that they would be prepared to use the iPhone modified bronchoscope in their clinical practice. The Glidescope was rated easiest to use (P < 0.001) and was the preferred device by all participants for the difficult airway scenario. CONCLUSIONS: The iPhone modified bronchoscope, in its current configuration, was found to be more difficult to use compared with the Glidescope® and unmodified bronchoscope; however it offered several advantages for teaching fibreoptic intubation technique when video-assisted bronchoscopy was unavailable.


Assuntos
Broncoscópios , Broncoscopia/instrumentação , Telefone Celular/instrumentação , Laringoscópios , Laringoscopia/instrumentação , Manequins , Adulto , Broncoscópios/normas , Broncoscopia/métodos , Telefone Celular/normas , Competência Clínica/normas , Desenho de Equipamento/normas , Feminino , Humanos , Laringoscópios/normas , Laringoscopia/métodos , Masculino , Pessoa de Meia-Idade , Prega Vocal/anatomia & histologia
15.
Respir Care ; 55(5): 595-600, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20420731

RESUMO

Diagnostic or therapeutic flexible bronchoscopy is often necessary in severely ill patients. These patients often have comorbidities that increase the risk of bronchoscopy-related complications. Noninvasive ventilation might decrease the risk of these complications in patients with severe refractory hypoxemia, postoperative respiratory distress, or severe emphysema, and in pediatric patients. Noninvasive ventilation may prevent hypoventilation in patients with obstructive sleep apnea and obesity hypoventilation syndrome who require bronchoscopy, and may assist in the bronchoscopic evaluation of patients with expiratory central-airway collapse. We describe the indications, contraindications, and technique of flexible bronchoscopy during noninvasive ventilation.


Assuntos
Broncoscópios/normas , Broncoscopia/métodos , Respiração com Pressão Positiva/instrumentação , Insuficiência Respiratória/diagnóstico , Desenho de Equipamento , Humanos , Insuficiência Respiratória/terapia
16.
Phys Med Biol ; 52(8): N163-71, 2007 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-17404451

RESUMO

We present the design of a sterilizable optical reference to characterize and quantify the inter-patient variations in tissue autofluorescence during autofluorescence bronchoscopy with Richard Wolf's diagnostic autofluorescence endoscopy (DAFE) system. The reference was designed to have optical and spectral properties similar to those of the human bronchial wall in spectral conditions corresponding to autofluorescence bronchoscopy conducted with the DAFE system (fluorescence excitation at 390-470 nm and red backscattering light at 590-680 nm). The reference's effective attenuation coefficient and reflectance were measured at 675 nm. In addition, its fluorescence emission spectrum was determined under 430 nm wavelength excitation. The reference is photostable, reproducible, biocompatible and small enough to be easily inserted through the working channel of a conventional bronchofibrescope. This cylindrical (length: 2 mm; diameter: 2 mm) optical reference was validated in a clinical environment.


Assuntos
Broncoscópios/normas , Análise de Falha de Equipamento/instrumentação , Análise de Falha de Equipamento/normas , Microscopia de Fluorescência/instrumentação , Microscopia de Fluorescência/normas , Óptica e Fotônica/instrumentação , Calibragem , Desenho de Equipamento , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Suíça
17.
Air Med J ; 25(2): 74-8; discussion 78-80, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16516118

RESUMO

INTRODUCTION: This study was designed to examine whether a handheld, battery-operated fiberoptic bronchoscope (FOB) used to verify endotracheal tube (ETT) placement would be as sensitive and specific as other modes and whether a combination of multiple modes would further enhance the sensitivity and specificity of ETT placement verification. SETTING: An academic hospital-based air medical program. METHODS: This was a prospective, randomized study examining surgical patients undergoing general endotracheal anesthesia. Eighteen critical care transport (CCT) nurses, previously unfamiliar with FOB, were asked to identify intratracheal and intraesophageal ETTs by using misting, end-tidal carbon dioxide concentration (ETCO(2)), and FOB alone or with a combination of all three modes. The sensitivity and specificity of single and multimode verification were calculated and compared. RESULTS: Comparison of ETT verification by single mode alone revealed a rank order of sensitivity with ETCO(2) (0.97) > FOB (0.87) > misting (0.84), whereas all three modes had similar specificities (0.93-0.94). However, the use of the three-mode combination revealed a sensitivity and specificity of 1.0. CONCLUSIONS: As a single mode for ETT verification, use of a handheld, battery-operated FOB device allowed for direct visualization and had an 87% sensitivity and 93% specificity. When combined with misting and ETCO(2), FOB allowed 100% successful verification of ETT placement.


Assuntos
Broncoscópios/normas , Tratamento de Emergência/instrumentação , Tecnologia de Fibra Óptica/instrumentação , Intubação Intratraqueal/métodos , Resgate Aéreo , Anestesia Endotraqueal/instrumentação , Broncoscópios/economia , California , Dióxido de Carbono/análise , Colorimetria , Enfermagem em Emergência , Tratamento de Emergência/economia , Desenho de Equipamento , Tecnologia de Fibra Óptica/economia , Humanos , Intubação Intratraqueal/efeitos adversos , Intubação Intratraqueal/instrumentação , Erros Médicos/prevenção & controle , Medição de Risco , Sensibilidade e Especificidade , Volume de Ventilação Pulmonar
20.
São Paulo; Secretaria da Saúde. Coordenação de Vigilância em Saúde; set. 2005. 2 p.
Não convencional em Português | LILACS, Coleciona SUS, COVISA-Producao, Sec. Munic. Saúde SP, Sec. Munic. Saúde SP | ID: biblio-937398
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...